Download - Structural Design Examples
-
8/3/2019 Structural Design Examples
1/13
Bisalloy Design Examples
Design
Examples
1 of 13 11 Aug 2006 Rev 1.
-
8/3/2019 Structural Design Examples
2/13
Bisalloy Design Examples
DESIGN EXAMPLES
The following five structural design examples demonstrate the significant savings which can
be achieved in the areas of weight and cost by using Grade 690 MPa Bisplate 80 steel
instead of the more commonly used lower grade structural steels. These examples primarily
compare Bisplate 80 to Grade 300 Plus Steel which is currently the most commonly usedstructural steel in Australia. Comparison with other steels are noted where appropriate.
The design examples are as follows:
Heavily Loaded Column
Heavily Loaded Beam - I section
Heavily Loaded Beam - Box section
Heavily Loaded Truss
70 MI Water tank
Where appropriate, these examples have been simplified as much as possible in order tofacilitate ease of comparison between the different steels. Each example contains a brief
explanation of the structural element and the loading applied. Also provided are some typical
examples of applications in which the structural element may be utilised.
DESIGN CODES RELATING TO THE USE OF HIGH STRENGTH QUENCHED AND TEMPERED PLATE
MEMBERS IN STRUCTURAL ENGINEERING APPLICATIONS.
There is currently no Australian Standard covering the design of structural elements utilising
high strength quenched and tempered steels. The SAA Steel Structures Code, AS 4100-1990,
may be used for the design of structures in steel grades up to 450 MPa, beyond which the
general provisions of the code are not applicable.
AS4100 does not exclude the use of structural steels in excess of 450 MPa yield stress.
However, in order to adequately design and demonstrate the validity of a design in such
steels, it is necessary to engage an appropriate international standard which has been
specifically developed to cater for the use of high strength steels.
One such code, and the most commonly used in Australia for design in high strength steels is
the American Institute of Steel Constructions (AISC) Specification For Structural Steel
Buildings - Allowable Stress Design and Plastic Design, June 1, 1989. This code has been
proven to provide relatively simple and efficient methods of structural design for all types ofstructural elements, and has been used in the development of each of the design examples
contained within this publication.
A limit state version of the AISC specification is also available, and should be equally
effective in the design of High Strength Steel structures. It should also be noted that Bisplate
80 steel, at 690 MPa yield stress, is right on the upper limit of 100 ksi yield stress steel
covered by the AISC specification. Above this yield stress the AISC specification is not
applicable.
2 of 13 11 Aug 2006 Rev 1.
-
8/3/2019 Structural Design Examples
3/13
Bisalloy Design Examples
EXAMPLE 1
HEAVILY LOADED COLUMN
Consider a braced column, 10m high, loaded
axially with an 11,000 KN factored live load
(Fig. 1).
Some examples of practical applications where
such a column may be required are as follows:
In multi-storey construction
Heavy industrial structures
Storage silos/Hopper supports
Structural column design was carried out
for Grade 300 MPa steel using AS4100-1990. C
Corresponding design was carried out forGrade 690 MPa Bisplate 80 Steel using the
AISC specification.
The results of each design are summarised in Table 1. Representative calculations are
provided on following pages.
STEEL GRADE MPa SECTION WEIGHT Kg/m300 500WC383 383
690tf = 20 d1 = 400tw = 16 bf = 500
207
3 of 13 11 Aug 2006 Rev 1.
-
8/3/2019 Structural Design Examples
4/13
Bisalloy Design Examples
COLUM DESIGN USING GRADE 300STEEL COLUMN DESIGN USING GRADE 690MPA YIELDDesign in accordance with AS4100 1900.
Fig 3
AS4100 500WC383Reference
Section Capacity6.2.1 NS = KfAnfy
An=Ag=Ae
Kf = 1.0
Ns = 13664 KN
Ns = 12,298 KN > N* OK
Member Capacity6.3.3 Nc = c Ns N
c = {[1-[1-(90/)2]}= 0.8945Nc = 12,222 KN
Nc = 11,000 KN N* OK
Nominal Mass of Column = 383 kg/m
STRENGTH BISPLATE 80
Design in accordance with American Institute of Steel
Construction Specification for Structural Steel Buildings - 1989.Ag = 48,800 mm
2
Ix = 1,890 x 106mm4
Iy = 751 x 106mm4
rx = 197mm
ry = 124mm
fy = 280 MPa
AISC Spec. Design Load = 11,000 =7,333KN
Reference 1.5
fa = 7,333 = 277.78 MPaAg
Fa = 40.29 ksi
B5 Check Local Buckling
Table B5.1 Flanges : 95 = 95 = 9.5 < b = 12.1
Fy 100 t
Kc 1.0
Slender Element
Table B5.1 Web: 253 = 253 = 25.3 > b = 25.0
Fy 100 t
Non-Compact Element
Slender elements involved
Design by Appendix B
App. B Stress Reduction Factor for Flange,
B5a Qs = 1.293 0.00309 b Fy = 0.907
t Kc
Stress Reduction Factor for Web,
Qa = 1.0
Member stress reduction factor,
Q = QsQa = 0.907
Ag = 26,400 mm2 = An = Ae
Iy = 416.8 x 106mm4
Ry = Iy A = 125.7mm
fy = 690 MPa
= 100 Ksi
4 of 13 11 Aug 2006 Rev 1.
-
8/3/2019 Structural Design Examples
5/13
Bisalloy Design Examples
COLUMN DESIGN USING GRADE 690MPA YIELD
STRENGTH BISPLATE 80(CONTINUED)
AISC Spec.
Reference
B5c Allowable Stress, Fa
C1c = 79.44 > kl
r
kl2
r
Q 1 - Fy2Cc
,2
Fa =
Eq A-B5-11 kl kl3
5 3 r r
3 + 8Cc 8Cc3
Fa = 43.13ksi > fa OK
Nominal mass of Column = 208 kg/m
5 of 13 11 Aug 2006 Rev 1.
-
8/3/2019 Structural Design Examples
6/13
Bisalloy Design Examples
EXAMPLE 2
HEAVILY LOADED BEAM (ISECTION)
Consider a beam with full lateral restraint spanning 10m, loaded continuously with a live load of 470
KN/m (factored) as shown in Fig.5.
Practical applications where such a beam ma
required are:
In multi-storey construction
Heavy industrial structures
Roof support in underground mining
Structural beam design was carried out for Grade 300 MPa steel using AS4100-1990. Corresponding
design was carried out for Grade 690 MPa Bisplate 80 steel using the AISC specification.
The results of each design are summarised in Table 2. Representative calculations are provided on the
following pages.
STEEL GRADEMPa
SECTION WEIGHT Kg/m
300 1200WB392 392
690
tf= 25 d1 = 850
tw = 12 bf = 450 256
Note that a significant reduction in the depth of the beam was achieved through the use of Bisplate 80, in addition to the
weight waving, while still satisfying the permissible deflection requirements. This is of great importance in underground
mining and multi-storey construction applications, where head room is at a premium.
6 of 13 11 Aug 2006 Rev 1.
-
8/3/2019 Structural Design Examples
7/13
Bisalloy Design Examples
BEAM DESIGN USING BEAM DESIGN USING GRADE 690MPA
GRADE 300STEEL YIELD STRENGTH BISPLATE 80Design in accordance with AS4100 1990.
7 of 13 11 Aug 2006 Rev 1.
-
8/3/2019 Structural Design Examples
8/13
Bisalloy Design Examples
EXAMPLE 3
HEAVILY LOADED BEAM (BOX SECTION)
Consider a beam with full lateral restraint spanning 10m, loaded continuously with a live load of 470
KN/m (factored) as shown in Fig 9.
Practical applications are :
Heavy industrial structures
Roof support in mining
A box section is effective in long spans where additional lateral restraint is required within the
beam section to compensate for a lack of external restraints.
A common application ofabox section fabricated from high strength Q & T steel in
which the load configuration varies significantly from that described above, is in the
lifting booms ofmobile cranes.
Structural beam design was carried out for both Grade 250 MPa steel and Grade 690 MPa
Bisplate 80 steel using the AISC specification.
The results of each design are summarised in Table 3. Representative calculations are
provided on the following pages.
Table 3:
STEEL GRADEMPa
SECTION WEIGHT Kg/m
250
tf= 40 d1 = 1120
tw = 10 bf = 500 490
690tf= 25 d1 = 850
tw = 8 bf = 450284
8 of 13 11 Aug 2006 Rev 1.
-
8/3/2019 Structural Design Examples
9/13
Bisalloy Design Examples
BOX SECTION BEAM DESIGN USING BOX SECTION BEAM DESIGN USING
GRADE 250MPA ASTMA36 GRADE 690MPA BISPLATE 80
In accordance with AISC Spec. In accordance with AISC Spec.
9 of 13 11 Aug 2006 Rev 1.
-
8/3/2019 Structural Design Examples
10/13
Bisalloy Design Examples
EXAMPLE 4
HEAVILY LOADED TRUSS
Consider a heavily loaded truss spanning 40m.
Some examples of practical applications where such a truss may be required include :
Underground construction supporting a trafficable roof
(e.g. a hydro-electric power station).
Multi-storey construction supporting several floors.
In this example the following loading parameters have been considered.
Truss spacing 10m
Live Load 3 KPa
Dead Load 1 KPa
Occasional Load 20 KN mid span
The resulting load configuration is illustrated in Fig.13.
10 of 13 11 Aug 2006 Rev 1.
-
8/3/2019 Structural Design Examples
11/13
Bisalloy Design Examples
Structural member design was carried out for Grade 300 and 350 MPa steels using AS4100
1990. Corresponding design was carried out for Grade 690 Bisplate 80 steel using the
American Institute of Steel Construction Specification for Structural Steel Buildings. Results
are summarised in Tables 4 and 5.
TRUSS DESIGN SUMMARY
Grade 300 & 350 MPa AS4100 1990
Table 4:MEMBER SECTION kg/m TOTAL LENGTH
mTOTAL WEIGHT
TONNES
Top Cord 310 UC 137 137 40 5.480
Bottom Cord 310 UC 96.8 96.8 40 3.872Webs 250 UC89.5
* (250 x 250 x 6 SHS)
89.5
(45)
87.3
(87.3)
7.814
(3.929)
Total Weight = 17.166(13.281)
*Figures in brackets correspond to the use of Grade 350 square
Hollow Sections as web members.
All other members are Grade 300.
Grade 690 Bisplate 80 AISC Spec.
Table 5:MEMBER SECTION kg/m TOTAL LENGTH
mTOTAL WEIGHT
TONNES
Top Cord tf = 10 d1 = 212tw = 8 bf = 256
55 40 2.200
Bottom Cord tf = 10 d1 = 212tw = 10 bf = 260
58 40 2.320
Webs tf = 8 d1 = 225tw = 6 bf = 256
43 87.3 3.754
Total Weight = 8.274
11 of 13 11 Aug 2006 Rev 1.
-
8/3/2019 Structural Design Examples
12/13
Bisalloy Design Examples
EXAMPLE 5
REVISED DESIGN FOR A LARGE WATERSTORAGE TANK
A water storage tank was originally designed in AS3678-1990 Grade 250 and 350 steel plateto the following parameters:
Height = 14.25m
Diameter = 83.8m
Capacity = 70 MI
The stress calculations for the original design are as shown in Table 6.
Table 6::DEPTH (m) PRESSURE
(KPa)
HOOP
TENSION(KN/m)
PLATE YIELD
STRENGTH(MPa)
PLATE
THICKNESS(mm)
STRESS
(MPa)
2.85 28.5 1194 250 10 1195.70 57.0 2388 250 20 119
8.55 85.5 3582 250 25 14311.40 114.0 4777 350 28 17114.25 142.5 5971 350 36 166
A revised design incorporating 690 MPa yield strength Q & T steel plates in the lower two
sections produced the following set of values, shown in Table 7.
Table 7:
DEPTH (m) PRESSURE(KPa)
HOOPTENSION
(KN/m)
PLATE YIELDSTRENGTH
(MPa)
PLATETHICKNESS
(mm)
STRESS(MPa)
2.85 28.5 1194 250 10 1195.70 57.0 2388 250 20 1198.55 85.5 3582 250 20 17911.40 114.0 4777 690 20 23914.25 142.5 5971 690 20 298
As shown in Fig. 15, this revised design resulting in a saving of 25% in the mass of steelwork
in the walls of the tank.
12 of 13 11 Aug 2006 Rev 1.
-
8/3/2019 Structural Design Examples
13/13
Bisalloy Design Examples
Please Note:Every care has been taken to ensure the accuracy of the design examples, however, the information is provided
as a guide only. A structural engineer should be consulted with respect to use for specific projects. Bisalloy doesnot warrant the suitability of the design examples for a particular purpose. The purchaser relies on its own skilland judgement as to the suitability of Bisalloy 80 (Bisplate 80) for its purpose.Bisalloy Steels shall not be liable for any loss or damage howsoever caused arising from the application of such
information.