Download - SUPPLIER DOCUMENT FRONT SHEET - Microsoft
Sheet 1 of 1 B01-0100.xls - Front sheet
01
Originator / Contractor Code
Short Requisition No / PO Identifier Sheet Rev
FC EL0016-A01 01
Alternative Document No: (if applicable):
Rev Orig. Chk'd App'd
01 IT DH NCR
Code
1
2
3
4
5
6
Date
Accepted (Reviewed and Agreed)
Comments to Incorporated and Resubmitted
Rejected, Do Not start work (Comments to be incorporated and resubmitted)
Description of Code
DateDescription
INITIAL SUBMISSION
Signature of Purchaser'sResponsible Engineer
SUPPLIER DOCUMENT FRONT SHEET
Supplier Name: ABB Ltd
For Information
20-Nov-13
Project ID
CLB
Equipment Tag No(s):
Supplier Document No:
Document Title:
Z-89901
GENERAL ARRANGEMENT - 13.8KV MAIN TEMPORARY SUBSTATION
Supplier Document Revision No.
Purchaser Document Number
Sequence no.
0100
SDDR code
B01
Purchaser Review of Supplier Document
Cancelled / Superseded
As-Built
10000
4000
5600 REF 1500 2900
51011008106580800 100100
500
100
1497
1803
100
NOTES:
ALL EXTERNAL HINGES AND REMOVABLE PANELS ARE FIXED WITH M8 STAINLESS STEEL TORX SECURITYSCREWS.
ALL REMOVABLE PANELS ARE FIXED WITH M10 STAINLESS STEEL TORX SECURITY SCREWS.
ALL DOORS AND REMOVABLE PANELS ARE 'EARTH BONDED'.
ALL ELECTRICAL ITEMS AS SPECIFICATION.
NON-DESTRUCTIVE TESTING (NDT):
ALL LIFTING LUG WELDS AND LIFT PATH WELDS ARE TO BE MAGNETIC PARTICLE TESTED TO BRADGATE WORKSPROCEDURE 010.INSPECTION / TEST RESULTS ARE TO BE RECORDED.
MATERIAL SPECIFICATION:
STRUCTURAL:ALL RHS AND SHS SECTIONS TO BS EN 10210 S355J2HALL PLATE MATERIAL OVER 5mm THK. TO BS EN 10025 S355J2ALL PLATE MATERIAL 5mm AND UNDER TO BS EN 10025 S275JRALL ALUMINIUM GLAND PLATES 6mm MARINE GRADE, 5083 - H111
CERTIFICATES FOR ALL STRUCTURAL MATERIALS WILL BE ISSUED IN PROJECT DOCUMENTATION.
ROOF:OUTER SKIN 14swg (2.0mm) ZINTEC SHEET.INNER SKIN 16swg (1.6mm) ZINTEC SHEET.TREATMENT 100mm RWA45 MINERAL WOOL.
WALL:OUTER SKIN 14swg (2.0mm) STEEL CORRUGATED SHEET.INNER SKIN 18swg (1.2mm) ZINTEC SHEET.TREATMENT 100mm RWA45 MINERAL WOOL.
FLOOR:STRUCTURE 300x100x46 UKPFC PERIMETER BEAMS.STRUCTURE 260x90x35 UKPFC CROSS BEAMS.STRUCTURE 125x65x15 UKPFC CROSS BEAMS.TRIMMERS 10swg FOLDED CHANNEL.FLOOR PLATE 5mm PLAIN STEEL PLATE.GLAND PLATES 6mm THK. MARINE GRADE ALUMINIUM PLATE.TREATMENT 100mm RWA45 MINERAL WOOL.
EARTH BAR 50x6 THK.FLAT NON INSULATED COPPER
DOOR FURNITURE DETAILS:
ACTIVE LEAF DOOR FURNITURE:EXTERNAL STAINLESS STEEL DOOR HANDLE EXIDOR (0210081005) LEVER OPERATED C/W EURO-PROFILECYLINDER & THREE KEYS.INTERNAL EXIDOR (0210180324) 3 POINT LATCHING EMERGENCY PANIC BAR & DOOR GEAR.INTERNAL & EXTERNAL PULL HANDLES (HENDERSON 436)DOOR STAY, BRADGATE STANDARD BCL-DS-01
INACTIVE LEAF DOOR FURNITURE:TOP & BOTTOM SPRING LOADED SHOOT BOLTS.
HINGES:FURGOCAR 304 STAINLESS STEEL MAINTENANCE FREE .
WEATHER LOUVERS (TRANSFORMER ROOM):
EXTERNAL WEATHER LOUVERS COMBINED WITH INTERNAL MESH GIVE AN IP33 PROTECTION RATING.
EARTH BAR:
INTERNAL HIGH LEVEL PERIMETER EARTH BAR, 50x6 thk. UN-INSULATED PLAIN COPPER MOUNTED ON TOP HATFOLDED SECTIONS. WITH DROPPERS & THROUGH WALL EXTERNAL CONNECTION POINTS. NOTE THAT ONLY THEHORIZONTAL CABLE CONNECTION EARTH BAR LENGTH WILL BE MOUNTED ON INSULATION BOBBINS. BOLTEDDISCONNECT LINK AT LOW LEVEL.
STAIR & LANDING:
STAIRS & LANDINGS ARE TO THE BRADGATE STANDARD STEEL CONSTRUCTION DESIGN CONFORMING TO THESTANDARDS OUTLINED IN EEMUA PUBLICATION 105 SEVENTH EDITION ' FACTORY STAIRWAYS, LADDERS ANDHANDRAILS'. LANDING GRATING IS SERRATED & STAIR TREAD NOSING IS NON-SLIP. ALL STAIRS & LANDINGSCOMPONETS ARE SUPPLIED WITH EARTH BONDING TAPPING POINTS. ALL STAIRS & LANDINGS COMPONENTS AREFINISHED 'HOT DIP GALVANISED' IN ACCORDANCE WITH BS EN ISO 1461:2009NOTE, THAT STAIRS & LANDINGS ARE DESIGNED FOR PERSONNEL ACCESS USE ONLY!I.E. NO EQUIPMENT IS TO BE PLACED ON THE LANDINGS.
UNDERSTRUCTURE:
THE UNDERSTRUCTURE IS DESIGNED AS A BOLT TOGETHER SET OF FRAMES.THERE ARE A TOTAL OF SIX FRAMES, TWO ALONG EACH SIDE & ONE EITHER END.THE MODULE WILL BE CONNECTED TO THE UNDERSTRUCTURE USING BRADGATE DESIGNED CLAMPS.THE UNDERSTRUCTURE WILL BE SUPPLIED WITH ADDITIONAL BRADGATE DESIGNED CLAMPS ALLOW THE WHOLESTRUCTURE & MODULE TO BE SECURELY FASTENED DOWN WHEN INSTALLED AT SITE.THE CLAMPS WILL BE FASTENED DOWN AT SITE BY USING MECHANICAL FIXINGS INTO THE CIVILS FOUNDATION /CONCORSE AREA. NOTE IT IS THE RESPONSIBILITY OF OTHERS TO SELECT & SUPPLY THE CORRECT MECHANICALFIXINGS FOR THE CLAMPING DOWN.THERE IS PROVISION PROVIDED TO FIT EARTH BONDING BETWEEN THE MODULE & THE UNDERSTRUCTURE FRAME& PROVISION TO EARTH BOND BETWEEN EACH OF THE UNDERSTRUCTURE FRAMES.THE UNDERSTRUCTURE WIL BE 'HOT DIP GALVANISED' IN ACCORDANCE WITH BS EN ISO 1461:2009
MODULE PAINT SPECIFICATION:
PAINT SYSTEM BRADGATE STD SPEC 005 (OFF SHORE).EXTERNAL DFT 220 MICRONS.INTERNAL DFT 150 MICRONS.
OUTSIDE BS 4800 10-A-05 GOOSEWING GREYINSIDE BRADGATE STANDARD WHITE.FLOOR BRADGATE STANDARD BLACK.UNDERSIDE BRADGATE STANDARD BLACK UNDERSEAL.
TRANSPORT & STORAGE:
ALL BUILDING DOORS WILL BE SECURED WITH A SCREWED RETAINING PLATE.ALL EXTERNAL LOUVERS WILL BE TEMPORARILY BOARDED WITH PLYWOOD SHEET C/W PLASTIC MEMBRANE.DURING TRANSPORTATION.TEMPORARY PLYWOOD BOARDING OF THE HVAC EXTERNAL CONDENSER.DURING LENGTHY SEA TRANSIT & ANY STORAGE, IT IS RECOMENDED THAT TEMPORARY BACK GROUND HEATINGIS USED TO ALLEVIATE THE ONSET OF A DAMP ATMOSPHERE.THE UNDERSTRUCTURE SUPPORT FRAMES, STAIRS & LANDINGS WILL BE SHIPPED IN STANDARD ISO CONTAINERS.
APPROXIMATE WEIGHTS AS SUPPLIED BY BRADGATE CONTAINERS LTD:
EMPTY MODULE ------------------------------------------------------------------- = 17,500 kgINSTALLED EQUIPMENT SUB TOTAL ---------------------------------------- = 13,350 kgBRADGATE ELECTRICAL EQUIPMENT (ESTIMATED.) ---------------- = 800 kg
TOTAL CALCULATED WEIGHT = 31,650 kg
PLEASE NOTE THAT THE EQUIPMENT INDIVIDUAL WEIGHTS SHOWN HAVE BEEN TAKEN FROMINFORMATION/DRAWINGS SUPPLIED TO BRADGATE CONTAINERS LTD. CUSTOMER TO ADVISE IF ANY OF THEEQUIPMENT WEIGHTS ARE INCORRECT PRIOR TO MANUFACTURE OF THE MODULE.
LIFTING & RIGGING OF MODULE:
4 OFF TOP LIFTING LUG POINTS ARE PROVIDED, NOTING THAT THESE LIFTING LUGS ARE ONLY TO BE USED FORLIFTING A FULLY FITTED OUT MODULE ONLY! THE UNDERSTRUCTURE OR STAIRS & LANDINGS MUST BE LIFTEDSEPERATLY. SEE LIFTING & RIGGING DRAWING 13238-1-5 FOR DETAILS.
FIRE PANEL
1325
℄
℄
℄
℄
TRIP &CLOSE UPS
150
900
750
505
INCOMER HOUSE TX.
REMOTE CTRLPANEL
SUBSTATIONSERVICESDIST.PANEL
350
RUBBER MAT IN FRONT OF SWITCHBOARDS
650150
HVAC AIR HANDLINGUNIT (AHU) SUSPENEDFROM CEILING
07
10
19 21
22 24
11
12
26
50
700
50
20
23
℄
TELESCOPICARC VENT
℄
ARC VENT DUCT
4000
1003800
100200
5
625315
125
HVAC AIR HANDLINGUNIT (AHU) SUSPENEDFROM CEILING
2587 APRROX.
LADDER RACKCARRYINGSERVICE CABLES
HVAC CONDENSATEDRAIN THRO' FLOOR
25
09
HVAC
08
06
05 04
02
M12 THRO' WALLEARTH BOSS
M12 THRO' WALLEARTH BOSS
01
15
13
14
29
28
30
31
32 18
17
600150 150
250
100
03
233526302132
16
A01 A02 A03 A04 A05 A06 A07 A08 A09 A10 A11 A12 A13
SWITCH BOARD
TRANSFORMER
HVAC CONDENSATEDRAIN THRO' FLOOR
1928
HV TERMINALS (PRIMARY SIDE)
LV TERMINALS (SECONDARY SIDE)
HV TERMINALS (PRIMARY SIDE)
LV TERMINALS (SECONDARY SIDE)
WHEEL
WHEEL
WHEEL
WHEEL
54
600
1400
13-OFF CABLE APERTURES THROUGH BASE FRAME& FLOOR PLATE. C/W MARINE GRADE ALUMINIUM
GLAND PLATES TO U/SIDE.(ACCESS FOR SWITCHBOARD CABLES)
13-OFF CABLE APERTURES THROUGH BASE FRAME& FLOOR PLATE. C/W MARINE GRADE ALUMINIUM
GLAND PLATES TO U/SIDE.(ACCESS FOR SWITCHBOARD CABLES)
625
165
205
204
90 425
405 110
250x250 APERTUREC/W 5 THK TOP COVER
270
600
450
600x250 APERTUREC/W 5 THK TOP COVER
250x250 APERTUREC/W 5 THK TOP COVER
300
300
640
1985
300
INTERNAL PLAN VIEW AT CEILING LEVEL
INTERNAL PLAN VIEW (INCLUDING ALL FLOOR APERTURES)
VERTICAL SECTION THRO' BUILDING
205204
SWITCH GEAR FIXING
650
2200
250X250 APERTUREFITTED AROUNDTRANSFORMERSUPPORT SKIDS
2600
2730
431
616
276
610
373
THIS DRAWING IS THE SOLE PROPERTY OF 'BRADGATE CONTAINERS LTD' AND MAY NOTBE COPIED OR USED FOR ANY PURPOSE OTHER THAN THAT FOR WHICH IT IS SUPPLIEDWITHOUT THE EXPRESS WRITTEN PERMISSION OF 'BRADGATE CONTAINERS LTD' (©2013)
BRADGATE CONTAINERS LTD. LEICESTER ROAD,
SHEPSHED, LEICS.
LE12 9EG
ISSUE SHEET SIZE
A0
BQ/
THIRD ANGLE PROJECTION
IF IN DOUBT ASK - DO NOT SCALE GENERAL FABRICATING TOLERANCES
ALL DIMENSIONS UP TO & INCLUDING 300 ±1 IN MILLIMETRES 301 UP TO 1500 ±2UNLESS STATED ABOVE 1500 ±3
DESCRIPTION
ORIGINAL ISSUE
ABB Ltd.
10.09.13I. TAYLOR17433
1:20
N/A NCR
DH 10.09.13
10.09.13
Equipment Layout of Main 13.8kV SubstationModule for BP Clair Ridge Temporary Substations
13238-1-1 D 1
SUPPLIER DRAWING DECAL
ProjectID
Alternative Document No.
1- Accepted (Reviewed andAgreed)
2- Comments to be Incorporatedand Resubmitted
Signature Date
3- Rejected, Do Not Start Work(Comments to beIncorporated andresubmitted)
4- For Information
Review Status
Short RequisitionNo/PO Identifier
Sequence Sheet. Rev
5- Cancelled/Superseded
6- As Built
Purchaser Document Number
Originator/ContractorCode
SDDRCode
CLB- AA- AANNNN-ANN ANN- NNNN- (NN) NN
B ALL DATA TABLE CHANGESNEW LIGHTS & TX APERTURE
11.09.13
C ALL CABLE LADDER REDUCEDFOR DOOR.ACCESS
23.09.13
D 2B TABLE UPDATED WITHHEAT LOSS FIGURES
19.11.13
4040
408
PLAN VIEW ON MODULE ROOF
Y
1500 29005600
10000
3000
300
1500
3708
5208
3000
SIDE ELEVATION
END VIEW
FREE STANDING UNDERSTRUCTUREBOLT TOGETHER FRAMES
2200
800
1094.5405.5
10000
3000
FREE STANDING UNDERSTRUCTUREBOLT TOGETHER FRAMES
HVAC CONDENSER HVAC SERVICES PASSTHROUGH TRANSIT
END VIEW
FAR SIDE ELEVATION ON ARROW Y
225525
5584
5
3400
754
11180 O/A LENGTH
STEEL STAIRS & LANDINGSDESIGNED IN ACCORDANCE WITHEEMUA PUBLICATION 105.C/W SERRATED GRATING &NON-SLIP EDGE TO STAIR TREADS.TUBULAR STEEL HAND-RAILING ISREMOVABLE.
HVAC
CON
DENS
ER
2 OFF EARTH BOSSES DIAGONALLYOPPOSITE TAPPED M12
(EXTERNAL BUILDING EARTH CONNECTION)
RETANGULAR BASE EYE PLATESFULLY WELDED TO SIDE & END RAILS
FOR LASHING DURING TRANSPORTATION(8 POSITIONS EACH SIDE & 4 POSITIONS EACH END)
FULLY REMOVABLE HEADER PANEL TOALLOW EQUIPMENT ACCESSC/W 2 OFF M12 EYEBOLTS TO BS4278
300
100
2335
23352630
4750
800
1405
1405 4000
1470.5
5
248
588
276 610
1800
06
16
HB
HB
HB
HB
HB
HB
HB
HB
8-OFF M16 SAFETYHARNESS BOSS
16 16
ARC VENT APERTUREC/W J SECTION GUTTER
ABOVE EXTERNALWEATHER COWL
75THK PERSONNEL / EQUIPMENT ACCESS DOUBLE DOORC/W 300x300 MM DOUBLE GLAZED WINDOW FITTED WITH GEORGIAN WIRED SAFETY GLASS.16SWG. ZINTEC INNER & OUTER SKIN, LINED WITH 45KG/M3 DENSITY MINERAL WOOLDOOR STAY: St.St. BSL-DS01. COMPRESSION SEAL ALL ROUND. ALL FIXINGS ARE SECURITY TYPE. HENDERSON 436 PULL HANDLES (INSIDE AND OUT),EARTH BOND AND J-SECTION GUTTER STRIP. 1 OFF SPRING BOLT (AJL REF: 0837/0001). 1 OFF LONG SPRING BOLT (BASED ON AJL 0837/0001)EXTERNAL DOOR FURNITURE: EXIDOR (021 008 1005) STAINLESS LEVER HANDLE C/W EURO-PROFILE CYLINDER.INTERNAL DOOR FURNITURE: EXIDOR (021 018 0324) 3-POINT LATCHING EMERGENCY PANIC BAR.HINGE: FURGOCAR 304 STAINLESS STEEL MAINTENANCE FREE HINGE. INOX COD. 1015-0619A
2995
INTL
WAL
L HT
& DO
OR A
PERT
URE
(TRA
NSOM
REM
OVED
)
605
650
605
1429030908
M12 THRO' WALLEARTH BOSS
M12 THRO' WALLEARTH BOSS
HVAC
CON
DENS
ER
17
28
05 04 03
HVAC
CON
DENS
ER 06
25
26
12
18
31
30
32
15
13
0201
EARTH BAR BOLTEDDISCONNECT LINK
EARTH BAR RISER MOUNTEDTO INNER WALL ON STEELBRACKETS (NON-ISOLATED)
PERIMETER EARTH BAR MOUNTEDTO INNER WALL ON STEELBRACKETS (NON-ISOLATED)
VERTICAL EARTH BAR MOUNTEDON ISOLATORS FOR CONNECTINGOF FIELD EARTH CABLES RISINGUP THROUGH FLOOR APERTURE
TELESCOPICARC VENT CONNECTION DUCT
ARC VENT COWL
4000
100 3800 100200
5 FLO
OR P
LATE
625315
125
HVAC AIR HANDLINGUNIT (AHU) SUSPENEDFROM CEILING
2587
APR
ROX.
LADDER RACKCARRYINGSERVICE CABLES
54
600
VERTICAL SECTION THRO' BUILDING ON 'B'-'B'
205 204
SWIT
CH G
EAR
FIXI
NG
50x50 ELECTRICAL TRUNKING
CABLE APERTURE C/W MARINEGRADE ALUM. GLAND PLATE
CABLE APERTURE C/W MARINEGRADE ALUM. GLAND PLATE
HVAC AHU CONDENSATEDRAIN PASSES OUT THRO'THE FLOOR
B
B
02
!Warning
No Equipment is tobe placed or wheeledonto the landing area
WARNING SIGN SHOWN, FITTEDTO INSIDE OF DOOR
THIS DRAWING IS THE SOLE PROPERTY OF 'BRADGATE CONTAINERS LTD' AND MAY NOTBE COPIED OR USED FOR ANY PURPOSE OTHER THAN THAT FOR WHICH IT IS SUPPLIEDWITHOUT THE EXPRESS WRITTEN PERMISSION OF 'BRADGATE CONTAINERS LTD' (©2013)
BRADGATE CONTAINERS LTD. LEICESTER ROAD,
SHEPSHED, LEICS.
LE12 9EG
ISSUE SHEET SIZE
A0
BQ/
THIRD ANGLE PROJECTION
IF IN DOUBT ASK - DO NOT SCALE GENERAL FABRICATING TOLERANCES
ALL DIMENSIONS UP TO & INCLUDING 300 ±1 IN MILLIMETRES 301 UP TO 1500 ±2UNLESS STATED ABOVE 1500 ±3
DESCRIPTION
ORIGINAL ISSUE
ABB Ltd.
13.09.13I.TAYLOR17433
1:30
N/A NCR
G.N.ROGERS 13.09.13
13.09.13
G.A. of Main 13.8kV Substation Module forBP Clair Ridge Temporary Substations
13238-1-1 B 2
SUPPLIER DRAWING DECAL
ProjectID
Alternative Document No.
1- Accepted (Reviewed andAgreed)
2- Comments to be Incorporatedand Resubmitted
Signature Date
3- Rejected, Do Not Start Work(Comments to beIncorporated andresubmitted)
4- For Information
Review Status
Short RequisitionNo/PO Identifier
Sequence Sheet. Rev
5- Cancelled/Superseded
6- As Built
Purchaser Document Number
Originator/ContractorCode
SDDRCode
CLB- AA- AANNNN-ANN ANN- NNNN- (NN) NN
B 4E'LANDING AREA' WARNING SIGN ADDED
TO INSIDE OF DOOR 19.11.13