Reduce Reuse Reclaim and Recycle
Appropriate use of land
Use water and energy efficiently
Enhance human health
Strengthen local economies
Conserve plants and animals
Sustainable Strategies
![Page 2: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/2.jpg)
Protect agricultural, cultural and archeological resources
Build and maintain economically
Nice to live in
Build it Beautiful
Sustainable Strategies
![Page 3: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/3.jpg)
Healthy Indoor Air
![Page 4: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/4.jpg)
Radon * Radon is estimated to cause
about 21,000 lung cancer deaths per year, according to EPA's 2003 Assessment of Risks from Radon in Homes (EPA 402-R-03-003). The numbers of deaths from other causes are taken from the Centers for Disease Control and Prevention's 1999-2001 National Center for Injury Prevention and Control Report and 2002 National Safety Council Reports.
![Page 5: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/5.jpg)
Radon
Zone 1 counties have a predicted average indoor radon screening level greater than 4 pCi/L (pico curies per liter) (red zones)
Highest Potential
Zone 2 counties have a predicted average indoor radon screening level between 2 and 4 pCi/L (orange zones)
Moderate Potential
Zone 3 counties have a predicted average indoor radon screening level less than 2 pCi/L (yellow zones)
Low Potential
![Page 6: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/6.jpg)
Radon
![Page 7: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/7.jpg)
What is Radon? A radioactive gas that
comes from the natural decay of uranium and is found in nearly all soils.
![Page 8: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/8.jpg)
Radon Radon gets into the home through
Cracks in concrete floors Construction joints Cracks in walls Gaps in suspended floors Gaps around service pipes Cavities inside walls The water supply (wells typically)
![Page 9: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/9.jpg)
RadonRadon Resistant Construction Techniques Gas Permeable Layer
This layer is placed beneath the slab or flooring system to allow the soil gas to move freely underneath the house. In many cases, the material used is a 4-inch layer of clean gravel.
Plastic SheetingPlastic sheeting is placed on top of the gas permeable layer and under the slab to help prevent the soil gas from entering the home. In crawlspaces, the sheeting is placed under the crawlspace floor.
Sealing and CaulkingAll openings in the concrete foundation floor are sealed to reduce soil gas entry into the home.
Vent PipeA 3- or 4-inch gas-tight or PVC pipe (commonly used for plumbing) runs from the gas permeable layer through the house to the roof to safely vent radon and other soil gases above the house.
Junction BoxAn electrical junction box is installed in case an electric venting fan is needed later.
![Page 10: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/10.jpg)
![Page 11: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/11.jpg)
![Page 12: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/12.jpg)
Volatile Organic Compounds Volatile organic compounds (VOCs) are
emitted as gases from certain solids or liquids. VOCs include a variety of chemicals, some of which may have short- and long-term adverse health effects.
![Page 13: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/13.jpg)
VOC’s Paints Lacquers Paint Strippers Cleaning Supplies Pesticides Building Materials Furnishings Glues Adhesives………
![Page 14: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/14.jpg)
Health Effects Eye nose and throat irritation Headaches Loss of coordination Nausea Liver damage Kidney damage Central Nervous system damage Cancer
![Page 15: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/15.jpg)
Formaldehyde What is Formaldehyde? Formaldehyde is a low cost and common
chemical that has a strong pickle-like odor. It is currently used in thousands of products as an adhesive, bonding agent and solvent.
![Page 16: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/16.jpg)
Formaldehyde Where is it found?
Particle board, plywood, paneling, pressed-wood products
Urea formaldehyde foam insulation Synthetic fabrics (especially permanent press) Produced through combustion
Natural gas Wood Gasoline Tobacco
![Page 17: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/17.jpg)
FormaldehydeHealth Effects Vary Eye, nose and throat irritation Coughing, headaches, dizziness, and nausea
The effects of long-term exposure are not well known
The United States Environmental Protection Agency has listed formaldehyde as a chemical that can possibly cause cancer in people.
![Page 18: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/18.jpg)
FormaldehydeWhat is an acceptable level in the home?0.10 PPM or less
If a higher level is measured steps should be taken to mitigate the problem
![Page 19: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/19.jpg)
FormaldehydeMethods for lowering levels Remove the source Treat the source Ventilate Control the climate Allow products to off-gas
![Page 20: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/20.jpg)
How are Radon and Formaldehyde Detected?
Radon Detection Kits www.radonzone.com
Formaldehyde www.rkiinstruments.com/pages/fp30.htm
![Page 21: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/21.jpg)
Bathroom Exhaust FansCODE for Baths with bathing or spas facilities:
Minimum 80 CFM Intermittent Ventilation required or
Continuous Ventilation System at 20 cfm
CODE for Toilet Rooms without bathing or spas facilities:
3SF Minimum Window ½ of which must be operable
Minimum 50 CFM Intermittent Ventilation
![Page 22: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/22.jpg)
Home Ventilation Institute Recommendations - Baths Bathrooms to 80SF - 80CFM fan (Code)
Bathrooms 81sf to 100 sf – 1 cfm per square foot (~ 8 air changes/hour)
Bathrooms over 100 sf add the CFM for each fixture Allow 50 CFM per standard toilets, shower and steam
shower (put on timer) Allow 100 CFM per Whirlpool, garden and hot tubs
HVI recommends continuous ventilations as augmentation to intermittent ventilation
![Page 23: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/23.jpg)
Bathroom Exhaust Fans A toilet in its own enclosure should have its own fan
Fans approved for wet areas should be placed over or very near the shower or tub when possible.
Bath doors should be undercut at least 3/4”
Leave fan on for 20 minutes after use of the bathroom
![Page 24: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/24.jpg)
Ventilation ConsiderationsFan Type Propeller Fan – Limited air capacity and noisy
Axial Fan – Better air movement but still noisy
Centrifugal Blower (Squirrel Cage) The best
![Page 25: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/25.jpg)
HumidistatnsHumidistat
![Page 26: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/26.jpg)
Kitchens
![Page 27: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/27.jpg)
Kitchen Exhaust FansCODE (ASHRAE) The American Society of
Heating, Refrigerating and Air-Conditioning Engineers
100 CFM IntermittentOr25 CFM Continuous
![Page 28: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/28.jpg)
Home Ventilation Institute Recommendations - Kitchens Wall Mount Hoods – 100 cfm per foot of width
Island Mount Hoods – 150 cfm per foot of width
![Page 29: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/29.jpg)
Air Flow Rules of ThumbRule of Thumb 1:Take the hood area (in square feet) andmultiply it by 75 to get the CFM (cubic feetper minute) for a wall hood, or multiply it by100 for an island hood.
Rule of Thumb 2:Allow 15 air changes per hour (ACH) for the kitchen.
Take the kitchen volume (length x width x height) and divide by 4 to get the required CFM.
![Page 30: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/30.jpg)
Rule of Thumb 3:
Allow 1 CFM per 100 BTU's per hour (BTUH) heat output.
Take the output of the oven and cooktop (if together or close) and divide by 100 to get the required CFM.
Rule of Thumb 4: (this applies to commercial type ranges)
Allow 100 CFM per linear foot of hood. Take the perimeter of the hood and multiply it by 100 to get
the required CFM.
Which rule of thumb is the best one to use?
The most popular rules of thumb are #1 and #3. We typically use rule of thumb #1 when we size fans.
![Page 31: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/31.jpg)
NKBA Recommendations
![Page 32: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/32.jpg)
Ventilation Calculator
![Page 33: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/33.jpg)
Why Ventilate?To provide enough air to keep occupants health
To remove odors
To dilute indoor pollutants
To lower relative humidity
![Page 34: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/34.jpg)
Negative Aspects Typical home
Gas furnace – vents to outside Gas Hot Water Heater – vents to outside 2 bath fans – vent to outside 1 kitchen ventilator – vents to outside
What happens when the home is winterized, windows closed, doors closed and all of these ventilators are running?
![Page 35: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/35.jpg)
Furnace
![Page 36: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/36.jpg)
Gas dryer
![Page 37: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/37.jpg)
Gas Hot Water Heater
![Page 38: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/38.jpg)
Hot Water Heater Vent
![Page 39: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/39.jpg)
-Negative Pressure Where does the makeup air come from?
![Page 40: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/40.jpg)
Hot Water Heater Vent
![Page 41: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/41.jpg)
Negative Pressure What happens when we tighten the
house up?
![Page 42: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/42.jpg)
How Tight is Too Tight? We need .35 air changes per hour. If less then
mechanical ventilation must be used
1500 SF house with 8’-0” ceilings
What is the total air volume inside the house? 12000 CF How many CFM do we need to move? 4200/60 = 70 CFM
![Page 43: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/43.jpg)
Heat Recovery Ventilator
![Page 44: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/44.jpg)
HRV
![Page 45: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/45.jpg)
HRV
![Page 46: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/46.jpg)
ERV Energy Recovery Ventilator Energy Recovery Ventilator Used in the southern states where
humidity is a problem Works the same as a HRV but ~ 9% of
the stale air mixes with the fresh air to adjust humidity.
![Page 47: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/47.jpg)
Bioclimate Chart
![Page 48: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/48.jpg)
Example 1 Dry Bulb 73° Relative Humidity 50%
![Page 49: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/49.jpg)
In the zone
![Page 50: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/50.jpg)
Example 2 Dry Bulb Temp. 78° Relative Humidity 70%
![Page 51: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/51.jpg)
![Page 52: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/52.jpg)
Example 2Dry Bulb Temp.
78°Relative Humidity
70%
Requires a wind speed of 250 FPM(250*60)/5280MPH = 2.84
![Page 53: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/53.jpg)
Example 3 Dry Bulb Temp. = 50°F Relative Humidity 55%
![Page 54: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/54.jpg)
![Page 55: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/55.jpg)
Example 4 Dry Bulb Temp. = 64°F Relative Humidity 40%
![Page 56: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/56.jpg)
![Page 57: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/57.jpg)
What Does All This Mean?
![Page 58: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/58.jpg)
Seasonal Enemies
RADIATION
CONDUCTION
CONVECTION
RADIATION
CONVECTIONCONDUCTION
Cooling: Heating:
![Page 59: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/59.jpg)
British Thermal Units The basic measure of heat The amount of heat needed to raise one
pound of water one degree Fahrenheit
BTU =
A kitchen match contains about 1 BTU of Heat Energy
![Page 60: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/60.jpg)
Heat Content of Fuels 1 Kilowatt-hour electricity = 3,413 Btu 1 cubic foot of natural gas = 1,025 Btu 1 gallon fuel oil = 138,700 Btu 1 gallon kerosene = 135,000 Btu 1 ton of coal = 27,000,000 BTU 1 gallon LPG = 91,000 Btu 1 pound LPG = 21,500 Btu
![Page 61: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/61.jpg)
Energy and Power Power is the INSTANTANEOUS use of energy
Think of it as POTENTIAL use, whether it is running or not (engine, light bulb)
Btu/h Watts, Kilowatts (Watts = Volts x Amps)
the amount of voltage across a circuit x the current through the circuit
Energy is USE of power over TIME (heat energy) Btu/h x hours = Btu Watts x hours = Watt hour (Kilowatt x h = kWh)
![Page 62: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/62.jpg)
FUELSNatural Gas - Piped in under
pressure Liquid Propane (LP) Stored in home
tankFuel OilElectricityCoalWood
![Page 63: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/63.jpg)
Forced Air Furnaces Gas AFUE - annual fuel-utilization-efficiency rating measured as a percentage
The higher the percentage, the more heat the furnace can ring from each therm of gas—and the lower the environmental impact of its emissions.
The lowest allowed is 78%
The most efficient models have an AFUE of about 97 percent—or near-total efficiency.
![Page 64: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/64.jpg)
Energy Star Qualified Minimum AFUE of 85% to 90%
![Page 65: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/65.jpg)
HEPA Filter
![Page 66: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/66.jpg)
![Page 67: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/67.jpg)
Standard Efficiency Furnace Steady State Efficiency or Combustion
Efficiency ~80% Annual Fuel Utilization Efficiently
(~65%)
![Page 68: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/68.jpg)
Standard Efficiency Furnace Incomplete Combustion 0.5 On-Cycle Stack Loss 20% to 25% Pilot Light Loss 6% Off Cycle Loss 0-10% Jacket Loss 0-0.2% Cycling Losses 0-10% Duct Losses 0-40%
Actual Heating System Delivered? 40%-65%
![Page 69: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/69.jpg)
High Efficiency Furnace Steady State Efficiency or Combustion
Efficiency ~90%
Annual Fuel Efficiency (AFUE Rate) ~90%
![Page 70: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/70.jpg)
High Efficiency Furnace Incomplete Combustion 0.5 On-Cycle Stack Loss <10% Pilot Light Loss 0% Off Cycle Loss 0% Jacket Loss 0-0.2% Cycling Losses 0-10% Duct Losses 0-40%
Actual Heating System Delivered? 70%-90%
![Page 71: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/71.jpg)
Two Measures of Efficiency in Heat Pumps HSPF – Heating SEER - Cooling
![Page 72: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/72.jpg)
Heating Seasonal Performance Factor (HSPF) BTU’s produced/watt-hours
Heat Pumps manufactured after 2005 must have a HSPF of at least 7.7
The Most efficient have a HSFP of 10
![Page 73: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/73.jpg)
Seasonal Energy Efficiency Ratio(SEER)
Power output/Power input The higher the number the more efficient
All Air Conditioning units sold after January 2006 must have a SEER rating of at least 13.
Energy Star central air conditioning must have a SEER rating of 14
Window air conditioners are exempt from this rating
Updating from a 9 SEER rated system to a 13 can save 30% on your energy consumption
![Page 74: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/74.jpg)
Pros and Cons of Heat Pumps Electrically Powered
Can be used in conjunction with a forced air furnace
Not well suited in extremely cold climate
Noise
![Page 75: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/75.jpg)
Radiant Floor HeatThree types Radiant Air Floors
Electric Radiant Floors
Hot Water (Hydronic)
![Page 76: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/76.jpg)
Radiant Floor HeatTypes of installationWet Installations Large thermal mass of a concrete slab floor lightweight concrete over a wooden subfloor Dry Installations Where the installer "sandwiches" the radiant floor
tubing between two layers of plywood or attaches the tubing under the finished floor or subfloor.
![Page 77: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/77.jpg)
Radiant Floor Heat Air Heated Radiant Floors Not
recommended for residential applications
Electric Radiant Floors -
![Page 78: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/78.jpg)
Electric Radiant Heat - Wet Installation
![Page 79: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/79.jpg)
Wet Installation
![Page 80: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/80.jpg)
Wet Installation
![Page 81: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/81.jpg)
Dry Installation
![Page 82: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/82.jpg)
Dry Installation
![Page 83: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/83.jpg)
Hydronic Radiant Heat
![Page 84: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/84.jpg)
Wet Installation PEX piping in Concrete (thick slab)
![Page 85: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/85.jpg)
![Page 86: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/86.jpg)
![Page 87: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/87.jpg)
Wet Installation Thin Slab Application Gypcrete over
plywd
![Page 88: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/88.jpg)
Heat Pump and Air Handler
Heat Pump
Air Handler
Air Cleaner
Thermostat
![Page 89: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/89.jpg)
Heat Pump and FurnaceIndoor Cooling Coil
Heat PumpFurnace
Air Cleaner
Thermostat
![Page 90: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/90.jpg)
Cooling
![Page 91: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/91.jpg)
Cooling
![Page 92: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/92.jpg)
Air Conditioner and Furnace
Air Conditioner
Furnace
Indoor Cooling Coil
Thermostat
Air Cleaner
![Page 93: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/93.jpg)
Air Conditioners and Air Handlers
Thermostat
Air Conditioner
Air Handler
Air Cleaner
![Page 94: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/94.jpg)
Cooling
![Page 95: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/95.jpg)
Whole House Ventilation
![Page 96: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/96.jpg)
Natural Ventilation
![Page 97: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/97.jpg)
Natural Ventilation
![Page 98: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/98.jpg)
Ceiling FansSizing Ceiling FansLargest dimension of room
Minimum Fan Diameter
12 feet or less 36-inches12 -16 feet 48-inches16 – 17.5 feet 52-inches17.5 -18.5 feet 56-inches18.5 feet 2 fans
![Page 99: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/99.jpg)
![Page 101: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/101.jpg)
Heating Degree Days Heating Degree Days are a measure of
how cold your climate is. If the average outside temperature for a
day is 1 degree less than the inside temperature (68°), then you would accumulate 1 degree day on that day.
http://www.ncdc.noaa.gov/oa/climate/online/ccd/nrmhdd.txt
![Page 102: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/102.jpg)
Portland Month starting HDD % Estimated 11/1/2011 603 0 12/1/2011 805 0 1/1/2012 749 0 2/1/2012 633 0.03 3/1/2012 622 0 4/1/2012 384 0 5/1/2012 282 0 6/1/2012 176 0 7/1/2012 69 0 8/1/2012 50 0 9/1/2012 110 0 10/1/2012 305 0.03 4788
![Page 103: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/103.jpg)
UA Calculation R = (A * Δ T) / (3.413 * W)
W = Watts 3.413 = Constant (BTU/Watt) ΔT = Change in temp A = Area in Square Feet
![Page 104: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/104.jpg)
R = (A * Δ T) / (3.413 * W)
Outside Temperature = 35° Heat source = 100 Watts Total Area = 520 SF Temperature inside = 55°
Calculate the R Value for the given area
R30
![Page 105: Sustainable Strategies](https://reader035.vdocument.in/reader035/viewer/2022062323/56816768550346895ddc4f2e/html5/thumbnails/105.jpg)
R = (A * Δ T) / (3.413 * W)
Outside Temperature = 20° Insulation = R30 Total Area = 3520 SF Home 30x40x8 Temperature inside = 68°
Calculate wattage of the heat source for the given area
1650.16Watts