Download - The EVlink Product Range EVlink Wallbox
The EVlink Product Range
22 | Electric vehicle charging solutions se.com
In short
Extensive choiceWallbox 'Standard' and Wallbox 'Plus' are each available in 14 versions: • Rated charging power: 3.7, 7.4, 11 or 22 kW • T2 socket outlet (with or without shutter) or attached cable (with T1 or T2 connector)
Charging station QR Code • To get the product datasheet or to join Customer Care Center with "mySchneider" app, flash the QR Code with your usual QR Code reader • To access cloud-based EcoStruxureTM Facility Expert app maintenance organizer: charging station registration, maintenance reports, (see page 25)
Robustness • Highly robust to mechanical impact: IK10 • Suitable for outdoor use: IP54 • Heavy duty T2 socket outlet with silver plated contacts avoiding overheating
Easy to use • "Plug and charge" • One-touch stop/restart • Attached cable rolled up around the Wallbox • 1 or 2 charging stations mounted on the same pole
Energy management options Only one option to be selected at once, or none
• Delayed start to charge only in off-peak hours • Temporary current limitation from 16 A (3.7 and 11 kW) to 10 A, or from 32 A (7.4 and 22 kW) to 16 A, to cut the risk of electric overload • Permanently adjust the maximum charging current available for the vehicle, to avoid tripping (utility meter or incoming circuit-breaker) when the overall consumption of the home is close to the subscribed power
The first two options are activated by closing an external contact (off-peak switch, load-shedding device, etc) hardwired to the single digital input.The third option is only available in Wallbox Plus when using the TIC ("Télé-Information Client") interface of French utility meters (single-phase residential only with Linky and former electronics meters)
Protection against earth leakage current (Wallbox Plus only)Wallbox Plus is fitted with a built-in protection against residual direct current (RDC-DD, as "Residual Direct Current Detecting Device"). This makes it possible to use an upstream type A protection against residual current (RCD) both in single-phase and three-phase, in accordance with the CENELEC HD 60364-7-722:2016 electrical installation standard.
Please note that despite the mandatory application of this new standard since February 2019, some countries may have not yet updated their national standard accordingly. National standards and codes prevail and the use of a RCD type A combined with a RDC-DD may be prohibited in three-phase.
EVlink Wallbox
SHOPI
In private parking area
At home — condominium
At home
Product QR code'FLASH ME'
EVlink Wallbox, a range made of Wallbox 'Standard' and Wallbox 'Plus'
se.com Electric vehicle charging solutions | 23
Application
Wallbox Standard and Wallbox Plus are recommended for homes, as well as tougher environments (condominium, corporate car park, hotel, etc.), because of their weatherproof and robust design.
Charging station unlocked Charging station locked
Locking the station with the key
• Impossible to insert the plug• Impossible to extract the cable• Impossible to stop/start charging
EVlink
Start
2
1
Stop
3
1
2
Single connector attached cable
Stop/restart button and charging status indicator light
Discovery
Charging station with attached cable Charging station with socket outlet
Type 1
Type 2
Cable unlocking button
Locking the charging station and cable with the key
Easy to install
Installation by a single technician in less than 30 minutes; no special tools required
Top, bottom or back side wiring
Immediate commissioning
HAZARD OF ELECTRIC
SHOCK, EXPLOSION
OR ARC FLASH
b Do not remove cover.
No user serviceable parts
inside. Refer servicing to
qualified personnel.
b Turn off all power
supplying this equipment
before working on or
inside equipment.
b Replace all devices,
doors and covers before
turning on power to this
equipment.
Failure to follow these
instructions will result
in death or serious
injury.
PELIGRO DE DESCARGA
ELÉCTRICA, EXPLOSIÓN O
ARCO ELÉCTRICO
b No retire la cubierta. No
contiene piezas que requieran la
intervención del usuario.
Solamente los trabajadores
cualificados deben efectuar el
mantenimiento de este equipo.
b Corte la alimentación del
equipo antes de trabajar en él.
b Vuelva a poner en su lugar
todos los dispositivos, puertas y
cubiertas antes de restaurar la
alimentación del equipo.
El incumplimiento de estas
instrucciones provocará la
muerte o lesiones graves.
RISQUE D'ÉLECTROCUTION,
D'EXPLOSION OU
D'ÉCLAIR D'ARC
b Ne retirez pas le couvercle. Ne
contient aucune pièce à réparer
ou entretenir par l'utilisateur. Seul
un personnel qualifié doit effectuer
l’entretien de cet appareil.
b Coupez l’alimentation de
l’appareil avant d’y travailler.
b Replacez tous les dispositifs,
les portes et les couvercles avant
de mettre l'appareil sous tension.
Si ces directives ne sont pas
respectées, cela entraînera la
mort ou des blessures graves.
DANGERPELIGRO
DANGER
HR
B86
755-
08
EVlink
Clack!
NHA31718-00
C
30,5 N.m
y 2,5 mm2
7 mm
L1NL2 L3 t
E1
E2
E6
y 16 mm2 y 10 mm2 y 6 mm2
C
10 mm1,8 N.m
4,5
HAZARD OF ELECTRIC
SHOCK, EXPLOSION
OR ARC FLASH
b Do not remove cover.
No user serviceable parts
inside. Refer servicing to
qualified personnel.
b Turn off all power
supplying this equipment
before working on or
inside equipment.
b Replace all devices,
doors and covers before
turning on power to this
equipment.
Failure to follow these
instructions will result
in death or serious
injury.
PELIGRO DE DESCARGA
ELÉCTRICA, EXPLOSIÓN O
ARCO ELÉCTRICO
b No retire la cubierta. No
contiene piezas que requieran la
intervención del usuario.
Solamente los trabajadores
cualificados deben efectuar el
mantenimiento de este equipo.
b Corte la alimentación del
equipo antes de trabajar en él.
b Vuelva a poner en su lugar
todos los dispositivos, puertas y
cubiertas antes de restaurar la
alimentación del equipo.
El incumplimiento de estas
instrucciones provocará la
muerte o lesiones graves.
RISQUE D'ÉLECTROCUTION,
D'EXPLOSION OU
D'ÉCLAIR D'ARC
b Ne retirez pas le couvercle. Ne
contient aucune pièce à réparer
ou entretenir par l'utilisateur. Seul
un personnel qualifié doit effectuer
l’entretien de cet appareil.
b Coupez l’alimentation de
l’appareil avant d’y travailler.
b Replacez tous les dispositifs,
les portes et les couvercles avant
de mettre l'appareil sous tension.
Si ces directives ne sont pas
respectées, cela entraînera la
mort ou des blessures graves.
DANGERPELIGRO
DANGER
HR
B86
755-
08
1 or 2 Wallbox on optional pedestal mounting pole
Scan or click on QR code
What's inside an EVlink Wallbox
EVlink Wallbox 'Standard' and EVlink Wallbox 'Plus'
The EVlink Product Range
24 | Electric vehicle charging solutions se.com
Characteristics
Power supply network • 220 - 240 V single-phase – 50/60 Hz for 3.7 and 7.4 kW charging stations • 380 - 415 V three-phase – 50/60 Hz for 11 and 22 kW charging stations • Suitable earthing systems:
- TT, TN-S, TN-C-S - IT (may require the addition of an isolating transformer to make it possible to charge certain vehicles)
Mechanical and environmental characteristics • Ingress protection code: IP54 • Impact protection code: IK10 • Operating temperature: -30°C to +50°C • Storage temperature: -40°C to +80°C • Attached cable length: 4 m • Energy management exclusive options: delayed charging start, temporary current limitation, real time maximum charging current control (Wallbox Plus only, combined with TIC interface of French utility meters)
Access control modes • Free access • Control by key lock, including charging cable locking
Warranty • 24 months for the entire EVlink range
Standards • IEC/EN 61851-1 ed 2.0 • IEC/EN 61851-22 ed 1.0 • IEC/EN 62196-1 ed 2.0 • IEC/EN 62196-2 ed 1.0.
(*) Granted to Wallbox Standard, planned for Wallbox Plus.
EVlink Wallbox
*
*Z.E. READY
> ROHS compliant> Reach compliant> EoLi: End Of Life Process> Product Environmental Profile compliant
Certification
EVlink Wallbox has obtained the CB test certificate issued by the LCIE test laboratory, establishing compliance with the IEC 61851-1 and IEC 61851-22 standards.
EVlink Wallbox 'Standard' and EVlink Wallbox 'Plus'
se.com Electric vehicle charging solutions | 25
Charging station references
EVlink Wallbox Description Socket outlet or connector type
Power (kW)Phases
References
Wallbox Standard Wallbox PlusWith socket outlet on right side (1) - Silver-plated contacts
T2 3.7 (1P - 16 A) EVH2S3P02K EVH3S3P02K7.4 (1P - 32 A) EVH2S7P02K EVH3S7P02K11 (3P - 16 A) EVH2S11P02K EVH3S11P02K22 (3P - 32 A) EVH2S22P02K EVH3S22P02K
T2 with shutters 3.7 (1P - 16 A) EVH2S3P04K EVH3S3P04K7.4 (1P - 32 A) EVH2S7P04K EVH3S7P04K11 (3P - 16 A) EVH2S11P04K EVH3S11P04K22 (3P - 32 A) EVH2S22P04K EVH3S22P04K
With attached cable 4 m, on right side - Silver-plated contactsT1 3.7 (1P - 16 A) EVH2S3P0AK EVH3S3P0AK
7.4 (1P - 32 A) EVH2S7P0AK EVH3S7P0AKT2 3.7 (1P - 16 A) EVH2S3P0CK EVH3S3P0CK
7.4 (1P - 32 A) EVH2S7P0CK EVH3S7P0CK11 (3P - 16 A) EVH2S11P0CK EVH3S11P0CK22 (3P - 32 A) EVH2S22P0CK EVH3S22P0CK
Protections and options with Wallbox StandardDescriptionCharging Single-phase Three-phase
Rated Power - Current 3.7 kW - 16 A 7.4 kW - 32 A 11 kW - 16 A 22 kW - 32 AProtection
Circuit breaker (overcurrent) (1) 20 A Curve C 40 A Curve C 20 A Curve C 40 A Curve CRCD (residual current) (1) 30 mA B Type for EV (2):
A9Z5122530 mA B Type for EV (2): A9Z51240
30 mA B Type for EV: A9Z51425
30 mA B Type for EV: A9Z51440
30 mA B-SI Type (2): A9Z61225
30 mA B-SI Type (2): A9Z61240
30 mA B-SI Type: A9Z61425
30 mA B-SI Type: A9Z61440
Under voltage tripping auxiliary with iC60 A9A26969 (optional) A9A26969 (3) A9A26969 (3) A9A26969 (3)
with DT40 A9N26969 (optional) A9N26969 (3) A9N26969 (3) A9N26969 (3)
Delayed startRelay With normally open contactTemporary current limitation
Relay With normally open contact
Protections and options with Wallbox PlusDescriptionCharging Single-phase Three-phase
Rated Power - Current 3.7 kW - 16 A 7.4 kW - 32 A 11 kW - 16 A 22 kW - 32 AProtection
Circuit breaker (overcurrent) (1) 20 A Curve C 40 A Curve C 20 A Curve C 40 A Curve CRCD (residual current) (1) 30 mA A-SI Type (2) 30 mA A-SI Type (2)
Under voltage tripping auxiliary with iC60 A9A26969 (4) A9A26969 (3)(4) A9A26969 (3)(4) A9A26969 (3)(4)
with DT40 A9N26969 (4) A9N26969 (3)(4) A9N26969 (3)(4) A9N26969 (3)(4)
Delayed startRelay With normally open contactTemporary current limitation
Relay With normally open contact
(1) References to be defined and local availability to be checked by Schneider Electric front offices. (2) In accordance with the electrical installation standard HD 60364-7-722:2016. Refer to local regulation.(3) Necessary to meet EV Ready requirements.(4) Mandatory for safety in case of charging station damage further to a short-circuit created by the vehicle.
(1) Cable available as an accessory.
The charging station operates autonomously. It has a dedicated protective device.
Installation: by an electrician
Location: residential, private usage
The EVlink Product Range
26 | Electric vehicle charging solutions se.com
Enables an operating check in the field of the charging station and charging cable.Reference: EVA1SADS
Floor standing: • for 1 Wallbox,
Reference EVP2PBSSG1• for 2 Wallbox,
Reference EVP2PBSSG2
EVlink Cable AC charging station testing tool
Pedestal mounting pole
To connect the car to the charging station. Available with a T1 or T2 connector.
Accessory references
EVlink Wallbox
Spare part references
Socket outlet References
T2S single-phase EVP1HSM41
T2 single-phase EVP1HSM21
T2S three-phase EVP1HSM43
T2 three-phase EVP1HSM23
Attached cable References
T1 charging connector
16 A single-phase EVP2CNS161A4
32 A single-phase EVP2CNS321A4
T2 charging connector
16 A single-phase EVP2CNS161C4
32 A single-phase EVP2CNS321C4
16 A three-phase EVP2CNS163C4
32 A three-phase EVP2CNS323C4
Front panel Reference
EVlink
EVP1HCWN
Key lock References
Key lock Random (1) EVP1HLSR
Key lock Single (1) EVP1HLSS
(1) Example: - If you order one EVP1HLSR: you will receive 1 lock + 2 keys with same code.- If you order one EVP1HLSS: you will receive 10 locks + 20 keys with same
code for all keys.
Please refer to page 46
NEWNEW
Available 4th quarter of 2020
se.com Electric vehicle charging solutions | 27
Practical information
Additional information for Wallbox Standard
Additional information for Wallbox Plus
Technical document Language References
With socket outlet
Instruction sheet EN/FR/DE/NO (1) PHA92084
SV/ES/NL/IT PHA92086
With attached cable
Instruction sheet EN/FR/DE/NO (1) PHA92085
SV/ES/NL/IT PHA92087
Technical document Language References
With socket outlet
Quick start guide EN/ES/FR/DE (1) NHA31789
IT/NL/PL/PT NHA31790
Instruction sheet EN/ES/FR/DE (1) NHA31778
IT/NL/PL/PT NHA31779
NO/SV/FI QGH34400
With attached cable
Quick start guide EN/ES/FR/DE (1) NHA31783
IT/NL/PL/PT NHA31784
Instruction sheet EN/ES/FR/DE (1) NHA31787
IT/NL/PL/PT NHA31788
NO/SV/FI QGH34396
5.6 kg (Wallbox Standard)6.3 kg (Wallbox Plus)
7.5 kg (Wallbox Standard with attached cable)7.9 kg (Wallbox Plus with attached cable)
331.5
480
800 min
170
Dimensions (mm)
To download the above documents, do a search by reference on www.schneider-electric.com
(1) Delivered with the Wallbox.
Register your charging station and improve your maintenance efficiency now with EcoStruxureTM Facility Expert.
• EcoStruxureTM Facility Expert is a simple, cloud-based tool that helps you organize maintenance records, follow-up on preventive maintenance, access log histories, create reports, and integrate remote alarming from your equipment.
• Let EcoStruxureTM Facility Expert help you optimize your maintenance activities. Download it for free on your PC or for your smart device at the Apple or Google Play store.
• You are ready to flash the product QR code with the EcoStruxureTM Facility Expert reader.
EcoStruxureTM Facility Expert