Power & Compression Systems
THE GAS TURBINE
and
THE ENVIRONMENT
AboutThe Instructor:Tony Giampaolo, P.E. is president of Power & Compression Systems, an engineering company providing custom designed control systems, design audits, feasibility studies, field test, and forensic engineering for engines, turbines, compressors, and control systems in simple and cogeneration cycle applications. Giampaolo has written a book "The Gas Turbine Handbook: Principles and Practices" and articles for Oil & Gas Journal, Diesel & Gas Turbine Worldwide, and Western Energy Magazines. He is a registered professional engineer in California, Florida, and Ohio, holding both Bachelor and Master of Science Degrees in Mechanical Engineering. He has been a part-time faculty member at California State University.
P.O. Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-8992
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-89921
Power & Compression Systems
CONTENTS
Introduction
Define Environment
Define Gas Turbine
Large, Medium, & Small (Micro-Turbine <100kw)
Gas Turbine's Impact On The Environment
Air Pollution
Noise Pollution
Environment's Impact On The Gas Turbine
Compressor Fouling
Turbine Erosion & Corrosion
Gas Turbine Applications Under Deregulation
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-89922
Power & Compression Systems
IntroductionThe affects of the environment on the gas turbine and the efforts to reduce the gas turbine's impact on the environment have a major impact on the expense of operating and maintaining a gas turbine.
This presentation addresses the impact gas turbines have on the environment and conversely the impact the environment has on gas turbines. Emissions will be discussed relative to natural sources of airborne contaminants, firing temperature, and fuel choice. Also, techniques to reduce emissions in the combustor and turbine exhaust will be examined. The impact of the environment on the gas turbine will focus on monitoring and controlling the quality, temperature, and relative humidity of the inlet air. How these affect unit performance, efficiency and fuel consumption will be weighed.
Both large and small-scale gas turbines will be important power sources throughout the next 100-to-200 years. To ensure continued acceptance, emissions must be eliminated or significantly reduced, component life must be increased, and operating cost must be reduced. Some of the techniques to achieve these goals will be addressed.
The information discussed in this presentation is excerpted from my book "The Gas Turbine Handbook: Principles & Practices", available through The Fairmont Press, Inc.
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-89923
Power & Compression Systems
EnvironmentThe Environment is all of the external factors, such as water, soil, climate, light, and oxygen affecting an organism. Specifically, in our case, it is the atmosphere or the ocean of air we live in.
Atmosphere is defined as a mixture of gases surrounding any celestial object that has a gravitational field strong enough to prevent the gases from escaping. The principal constituents of our atmosphere on earth are nitrogen (78 percent) and oxygen (21 percent). The atmospheric gases in the remaining 1 percent are argon (0.9 percent), carbon dioxide (0.03 percent), varying amounts of water vapor, and trace amounts of hydrogen, ozone, methane, carbon monoxide, helium, neon, krypton, and xenon.
Greenhouse Effect describes the role the atmosphere plays in insulating and warming the earth's surface. The atmosphere is largely transparent to incoming short-wave solar radiation, which is absorbed by the earth's surface. Much of this radiation is then reemitted from the earth at infrared wavelengths, but it is reflected back to the earth by gases such as carbon dioxide, methane, nitrous oxide, and ozone in the atmosphere. The reflected radiation maintains the temperature of the earth in a range that is hospitable to life. This heating effect is the basis of the theories concerning global warming.
The amount of carbon dioxide in the atmosphere has been increasing by 0.4 percent a year1 because of the use of fossil fuels such as oil, gas, and coal. The clearing of tropical forests has also been a contributing factor. Other gases that contribute to the greenhouse effect, such as methane and chlorofluorocarbons, are increasing even faster. The net effect of these increases could be a worldwide rise in average global temperature of 1.0° to 3.5° C (1.8° to 6.3° F), with a best estimate of 2.0° C (3.6° F), by 2100. Warming of this magnitude would alter climates throughout the world, affect crop production, and cause sea levels to rise significantly. If this happened, millions of people would be adversely affected by major flooding.2
Note:
1 cubic meter = 35.3 cubic feet1 milligram (1mg) = 0.00004 oz. (0.4x10-4)1 microgram (1g) = 0.00000004 oz (0.4x10-7)
1 Note: 0.4% of 0.03% = 0.00012% increase per year2"Greenhouse Effect," Microsoft® Encarta® 97 Encyclopedia. © 1993-1996 Microsoft Corporation. All rights reserved.
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-89924
Power & Compression Systems
DIVISIONS OF THE ATMOSPHERE
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-89925
Power & Compression Systems
MAJOR AIR POLLUTANTS
Major Air PollutantsSources of major air pollutants include individual actions, such as driving a car, and industrial activities, such as manufacturing products or generating electricity. Note: 1 cubic meter (1m3) is equal to 35.3 cu ft; 1 milligram (1 mg) is equal to 0.00004 oz; 1 microgram (1µg) is equal to 0.00000004 oz.
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-89926
Power & Compression Systems
Define Gas Turbine
Gas Turbine is an engine that employs gas flow as the working medium by which heat energy is transformed into mechanical energy. Therefore, all gas turbines are gas generators. Gas turbines are often classified by their physical size, by the amount of power they produce, by their design criteria, or by their originally intended or modified use. Therefore, we have aircraft or jet engines and aero-derivatives describing engines originally built for flight applications and modified for stationary, land based applications; and we have industrial engine designs that are similar to steam turbines - these are often identified as "heavy industrial" gas turbines. This was the design that existed in the first quarter of this century. It was this gas turbine design that Dr. W.J. Stern, then Director of the South Kensington Laboratory declared "unworkable" as a power source for British fighter aircraft. Several years later Frank Whittle demonstrated a workable lightweight gas turbine and became the Father of the modern jet engine (he shares this honor with Hans Pabst von Ohain who developed a similar engine for Germany at approximately the same time).
Large, Medium, & Small (Micro Turbine <100kW)
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-89927
Power & Compression Systems
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-89928
Power & Compression Systems
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-89929
Power & Compression Systems
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899210
Power & Compression Systems
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899211
Power & Compression Systems
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899212
Power & Compression Systems
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899213
Power & Compression Systems
Gas Turbine's Impact on the Environment
Air pollutionNOx, CO, NMHC
Noise pollution
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899214
Power & Compression Systems
AIR POLLUTION
CONTAMINATION OF THE AIR
IN LARGE ENOUGH CONCENTRATION,
FOR A SUFFICIENTLY LONG TIE,
TO CAUSE DAMAGE OR UNREASONABLE
INTERFERENCE WITH LIFE AND PROPERTY
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899215
Power & Compression Systems
NATURAL & MAN-MADE SOURCES OFATMOSPHERIC CONTAMINANTS
Emission Natural - kg/yr Man-Made - kg/yr Ratio Natural/Man Made
Reference
Hydrocarbons
Carbon Monoxide
Sulfur Oxides
Nitrogen Oxides
159x109
3.2x1012
415x109
45x1010
24x109
0.24x1012
139x109
4.5x1010
6
13
3
10
5
7
5,9,10
6,3
RESIDENCE TIME OF ATMOSPHERIC
TRACE ELEMENTS
Emissions Life Reference
CO 1-3 years 4
NO 1/2 - 1 day 6
NO2 3-5 days 6
HC (AS CH4) 1.5 years 4
SOX 3 - 4 days 6
P-M hours to days (troposphere)
days to years (stratosphere)
8
References:
(3) Abatement of Nitrogen Oxides Emissions for Stationary Sources”, National academy of Engineers (1972)(4) “Carbon Monoxide: Natural Sources Dwarf Man’s Output”, T.N. Maugh II (1972)(5) “Atmospheric Chemistry: Trace Gases and Particulates”, W.H. Fisher (1972)(6) “Emissions, Concentrations, and Fate of Gaseous Pollutants”, R. Robinson, R.C.
Robbins(1971)(7) The Sulfur Cycle”, W.W. Kellogg (1972)(8) “Physical Climatology”, W.D. Sellers (1965)(9) Ground Level Concentrations of Gas turbine Emissions”, H.L. Hamilton, E.W.
Zeltman (1974)(10) Air Quality Standards National and International”, S. Yanagisawa, (1973)
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899216
Power & Compression Systems
GAS TURBINE EXHAUST PRODUCTS
FROM
HYDROCARBON FUEL COMBUSTION IN DRY AIR
CONSTITUENT % BY WEIGHT REMARKS
N2 - Nitrogen 74.16 Mostly inert, from atmosphere
O2 - Oxygen 16.47 From excess air
CO2 - Carbon Dioxide 5.47 Product of complete combustion
H2O - Water 2.34 Product of complete combustion
A - Argon 1.26 Inert, from atmosphere
UHC - Unburned Hydrocarbons trace Product of incomplete combustion
CO - Carbon Monoxide trace Product of incomplete combustion
NOx - Oxides of Nitrogen
Thermal
Organic
trace
From fixation of atmospheric N2
From fuel bound nitrogen
SOx - Oxides of Sulfur From Sulfur in fuel
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899217
Power & Compression Systems
SCAQMD Environmental Rules & Regulations
Rule 1110.2Owners/operators of stationary engines with an amended Rule 1110.1 Emission Control Plan submitted by July 1, 1991, or an Approved Emission Control Plan, designating the permanent removal of engines or the replacement of engines with electric motors, in accordance with subparagraph (d) (1)(A), shall do so by December 31, 1999, or reduce the emissions from the engines to the limits listed in Table VI in accordance with the following schedule:
(i) By January 1, 1999, submit applications for permit to construct and permit to operate the engines and control equipment; (ii) By September 30, 1999, initiate control equipment installation; and (iii) By December 31, 1999, have the engine under compliance.
TABLE VIALTERNATIVE TO ELECTRIFICATION
NOx VOC CO 0.15 g/bhp-hr 0.15 g/bhp-hr 0.6 g/bhp-hr
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899218
Power & Compression Systems
SCAQMD Environmental Rules & Regulations
Rule 1134
(c) Emissions Limitations 1. The operator of any stationary gas turbine unit shall not operate such unit under
load conditions, excluding the thermal stabilization period or other time period specified in the Permit to Construct or the Permit to Operate issued prior to August 4, 1989, which result in the discharge of oxides of nitrogen (NOx) emissions, directly or indirectly, into the atmosphere at concentrations in excess of the following as measured pursuant to subdivision (e):
Compliance Limit = Reference Limit x EFF/25%
Where: Compliance Limit =
allowable NOx emissions (ppm by volume).
Reference Limit = the NOx emission limit (ppm by volume) is corrected to 15 percent oxygen on a dry basis, and averaged over 15 consecutive minutes. These limits for various megawatt ratings (continuous rating by the manufacturer without power augmentation) are as follows:
REFERENCE NOx LIMITS, PPM Unit Size
Megawatt (MW) Rating Effective
12-31-950.3 to Less Than 2.9 MW 252.9 to Less Than 10.0 MW 92.9 to Less Than 10.0 MW No SCR 1510.0 MW and Over 910.0 MW and Over No SCR 1260 MW and Over Combined Cycle No SCR 1560 MW and Over Combined Cycle 9
Effective 4/11/972.9 to Less Than 10.0 MW Utilizing Fuel Containing a Minimum of 60% Sewage Digester Gas by Volume on a Daily Average
25
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899219
Power & Compression Systems
Oxides of Nitrogen Emissions:
Oxides of nitrogen are produces primarily as nitric oxide (NO) in the hotter regions in the combustion reaction zone of the combustor.
Nitrogen oxides (NOx), found in the exhaust, are the products of the combustion of hydrocarbon fuels in air.
In this process nitrogen oxides are formed by two mechanisms: a) Thermal NO, and b) Organic NO
The predominant mechanism in the formation of NOx in gas turbine combustors
depends on such conditions as
the reaction temperature,
the resident time at high temperature,
the fuel/air ratio in and after the combustion reaction zone,
the fuel composition (the fuel bound nitrogen {FBN} content),
the combustor geometry, and
the mixing pattern inside the combustor
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899220
Power & Compression Systems
Oxides of Nitrogen Emissions:
Thermal NO produced in the hottest regions of the combustor extremely temperature dependent
Organic NO formed during combustion by chemical combination of the nitrogen
atoms, which are part of the fuel molecule and the oxygen in the air
The amount of Organic NO produced is affected by
the nitrogen content of the fuel,
a yield factor (a measure of FBN),
the fuel/air ratio, and
abatement techniques such as water injection.
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899221
Power & Compression Systems
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899222
Power & Compression Systems
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899223
Power & Compression Systems
SELECTIVE CATALYTIC REDUCTION
NOx is removed from the exhaust gas stream by the injection of ammonia (NH3) into the stream and the subsequent chemical reaction in the presence of a catalyst.
For a given gas condition (temperature, gas composition, etc.) the performance of the SCR is a function of the catalyst type and geometry, the residence time of the gas in the reactor, and the amount of ammonia injected upstream of the reactor.
Selection of the catalyst is specific to the temperature in which it is expected to operate.
The ammonia utilized in the process may be either anhydrous or aqueous.
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899224
Power & Compression Systems
Noise PollutionGas turbines are inherently noisy machines. Air rushing into the front of the compressor and exhaust gases rushing out of the turbine generates some of the noise. Another source of noise is the interaction between each moving airfoil and each stationary airfoil and strut. Noise levels generated by a gas turbine exceed the safe levels and must be attenuated.
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899225
Power & Compression Systems
Environment's Impact On the Gas Turbine
Airborne Contamination (salts, sand, dust, etc)
These have a detrimental impact on the compressor and the turbine Compressor Fouling Turbine Erosion & Corrosion
Ambient Temperature
The gas turbine is very sensitive to temperature. As temperature increases above 60 degrees F, gas turbine power decreases.
In some cases this power loss can be recovered by employing inlet air cooling (either evaporative cooling or refrigerated inlet air).
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899226
Power & Compression Systems
ENVIRONMENTAL CONDITIONS
Desert - sand, salt, dust Coastal - salt Agricultural - dust, pollen, chemicals (fertilizers) Arctic - snow, ice.
CONTAMINATIONS LEVELS
>5.0um dust, rain, fog, chemicals, minerals & metals 1-2um dust, salts, fog, soot, chemicals, minerals &
metals 0.3-0.5um hydrocarbon emissions, smog.
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899227
Power & Compression Systems
FILTER TYPES
Inertial Separators with & without dust removal capability
Prefilters similar in purpose to the inertial separator
Intermediate Filters with & without viscous coating
High Efficiency Filters
Cannister Filters with & without self-clean feature, and with & without prefilters
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899228
Power & Compression Systems
FILTRATION PROBLEMS
The filter may not be properly installed,
The wrong type of filter media may have been installed,
The filter element may not be properly maintained,
The filter plenum may not be properly maintained,
The operating environment has changed since the unit was installed.
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899229
Power & Compression Systems
FACTORS AFFECTING FILTER PERFORMANCE
AIR VELOCITY THROUGH THE FILTER
FILTER MEDIA'S ABILITY TO TOLERATE MOISTURE
AIR LEAKS AROUND THE DOORS AND WINDOWS
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899230
Power & Compression Systems
HOW TO IMPROVE FILTER PERFORMANCE
SET A TARGET FOR DELTA-P
LOAD FILTER TO THE “-P” TARGET
USE PREFILTER WARP (AFTER “-P” IS REACHED)
TO
EXTEND TIME AT THIS LEVEL OF FILTER
EFFICIENCY.
ELIMINATE THE USE OF MANUAL
OPERATION OF SELF-CLEAN SYSTEM.
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899231
Power & Compression Systems
COMPRESSOR FOULING
2% DROP IN c = (CDP/Pinlet)K-1/K - 1(T2/TA)-1
2% DROP CDP AT CONSTANT SPEED AND LOAD
3~5% REDUCTION IN LOAD CAPACITY PLUS A ONEPSIG DECREASE IN CDP AT CONSTANT CIT
CARBO BLAST*
WATER WASH CLEANING AGENTS
SOAP SOLUTION
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899232
Power & Compression Systems
Gas Turbine Applications under Deregulation
Power Generation Electric Mechanical Drive (compressors, pumps, etc.)
Waste Heat RecoveryCogeneration
Heating and/or coolingCombined Cycle
Power GenerationWhere Applied:
Central Power Plant On-Site Power Production
"Up to 20% (or 1300megawatts) of California's power forecasted demand of 6500MW by the year 2005 is projected as being potentially met by distributed generation".3
"EPRI projects the distributed energy resources up to 5 megawatts in size will meet 20% to 30 % of the nations demand over the next 20 years."4
Over the next 10 years utilities will shutdown nearly 20 GW of nuclear capacity that will have reached the end of its life. Gas turbine based combined-cycle units will probably replace many of those retired nuclear units.5
85% of our electrical outages occur due to transmission and distribution network problems.6
The cost of new transmission is approximately $1,000,000 a mile.7
For on-site applications to be successful they must be less expensive to install and operate than the alternative of purchasing power (or heat).
These new gas turbines must be more efficient and produce less contaminants. More efficient units will burn less fuel, and generate less CO2 per unit of power produced.
3 California Manufacturer Article "What's In It For You" by Eric Wong, Spring 19974 California Manufacturer Article "What's In It For You" by Eric Wong, Spring 19975 "Combustion Turbines Move Markets", by Jonh C. Zink, PH.D., P.E., Power Engineering, March 19986 California Manufacturing Article "What's In It For California" by Tom Tanton, Spring 19977 "A Regulator's perspective on Distributed Resources", by Renz D. Jennings, CADER 1997 distributed Resources Conference September 15, 1997.
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899233
Power & Compression Systems
Gas Turbine ApplicationsGeneral
Power Generation Electric Mechanical Drive (compressors, pumps, etc.)
Waste Heat RecoveryCogeneration
Heating and/or coolingCombined Cycle
Power Generation
Gas Turbine Applications after Deregulation
On-Site Power Production up 20%-30%Provided by Units under 5 MW
SCAQMD Environmental Rules & RegulationsRule 1110.2Owners/operators of stationary engines with an amended Rule 1110.1 Emission Control Plan submitted by July 1, 1991, or an Approved Emission Control Plan, designating the permanent removal of engines or the replacement of engines with electric motors, in accordance with subparagraph (d) (1)(A), shall do so by December 31, 1999, or reduce the emissions from the engines to the limits listed in Table VI in accordance with the following schedule:
(i) By January 1, 1999, submit applications for permit to construct and permit to operate the engines and control equipment; (ii) By September 30, 1999, initiate control equipment installation; and (iii) By December 31, 1999, have the engine under compliance.
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899234
Power & Compression Systems
TABLE VIALTERNATIVE TO ELECTRIFICATION
NOx VOC CO0.15 g/bhp-hr 0.15 g/bhp-hr 0.6 g/bhp-hr
SCAQMD Environmental Rules & Regulations, Rule 1110.2
TABLE VIALTERNATIVE TO ELECTRIFICATION
NOx VOC CO0.15 g/bhp-hr 0.15 g/bhp-hr 0.6 g/bhp-hr
SCAQMD Environmental Rules & Regulations, Rule 1110.2
SCAQMD Environmental Rules & RegulationsRULE 1134(c) Emissions Limitations
2. The operator of any stationary gas turbine unit shall not operate such unit under load conditions, excluding the thermal stabilization period or other time period specified in the Permit to Construct or the Permit to Operate issued prior to August 4, 1989, which result in the discharge of oxides of nitrogen (NOx) emissions, directly or indirectly, into the atmosphere at concentrations in excess of the following as measured pursuant to subdivision (e):
Compliance Limit = Reference Limit x EFF/25%
Where: Compliance Limit = allowable NOx emissions (ppm by
volume).Reference Limit = the NOx emission limit (ppm by volume)
is corrected to 15 percent oxygen on a dry basis, and averaged over 15
PO Box 3028, Mission Viejo, CA 92690 Phone (949)582-8545 Fax (949)582-899235
Power & Compression Systems
consecutive minutes. These limits for various megawatt ratings (continuous rating by the manufacturer without power augmentation) are as follows:
REFERENCE NOx LIMITS, PPM Unit Size
Megawatt (MW) Rating Effective 12-31-95
0.3 to Less Than 2.9 MW 252.9 to Less Than 10.0 MW 92.9 to Less Than 10.0 MW No SCR 1510.0 MW and Over 910.0 MW and Over No SCR 1260 MW and Over Combined Cycle No SCR 1560 MW and Over Combined Cycle 9
Effective 4/11/97
2.9 to Less Than 10.0 MW Utilizing Fuel Containing a Minimum of 60% Sewage Digester Gas by Volume on a Daily Average
25
REFERENCE NOx LIMITS (PPM)
Unit Size Megawatt (MW) Rating
Effective 12-31-95
0.3 to Less Than 2.9 MW 252.9 to Less Than 10.0 MW 92.9 to Less Than 10.0 MW No SCR 1510.0 MW and Over 910.0 MW and Over No SCR 1260 MW and Over Combined Cycle No SCR 1560 MW and Over Combined Cycle 9
Effective 4/11/97
2.9 to Less Than 10.0 MW Utilizing Fuel Containing a Minimum of 60% Sewage Digester Gas by Volume on a Daily Average
25
SCAQMD Environmental Rules & Regulations, RULE 1134