1. Outstanding throughputTD-30R(120 tubes) and TD-30 (60 tubes) make it possible to use night time and weekend with high throughput with overlap function.
2. Restoring the sampleThe Tube quick cooling mechanism on the TD-30R made it possible to restore and reanalyze the sample.
3. TraceabilityNot only result of leak test, recorded temperature and flowrate helps to trace the reason of fault.Optional bar code reader allows samples to controlled using bar codes.Internal standard addition function on TD-30R helps to confirm the result of analysis.
4. Robustness and easy maintenanceNew designed tube protector prevents the tube related trouble.The seal trap and other consumables can easily be replaced from the top of instrument.
5. Ease of useAn easy-to-learn user interface and flexible setting help to prevent operating errors.
TD-30 Thermal Desorption SystemA Revolutionary TD with outstanding high throughput and reliability
The TD-30 series is developed for best solution of gas and material analysis. Its out standing high throughput and user-friendly design support all types of analysis, from research to quality control.
Outstanding throughput
Sample capacity
Tube conditioning mode
The capacity of 120 samples of TD - 30R and 60 samples of TD - 30 enables efficient use at night and on weekends.The analysis schedule can be set up to 1000 lines with the batch editor.The sample tray at the low position on the front of the instrument is accessible even during analysis and prevents misplacement of the tube.
Tube conditioning function allows you to condition a large number of tubes for sampling.
TD-30R TD-30
Comply to every tube
Various sample tubes sold for Shimadzu TD can also be used.The sample tube of ¼ 'x 3.5' corresponds to many sampling equipment and peripheral equipment.
Over-lap analysis
The time of analysis cycle is decreased by Over-lap function. If GC is not Ready, wait for injection to avoid analysis failure.
Restoring the sample
Quick cooling
Tube Desorb
Quick cool
•Simultaneous analysis from low to high boiling point compound
TD-30R Restoring analysis
Boiling pointLow High
Immediately after the tube desorb are completed, the tube heating block moves away from the tube and the tube is cooled at high speed by air blowing by the fan.As a result, sample tubes are held without breakthrough of low boiling point components.Since there is no need to replace the tube, there is no need to worry about air mixing due to tube replacing.
Flow path without cold point
Since there are no cold point on flow path recovery rete of High-boiling point components is high.A sharp peak shape can be obtained with a short transfer line with a small dead volume.
1st analysis
2nd analysis
Analysis of High boiling point hydro carbons
Traceability
When an optional bar code reader is installed, the bar code printed on the tube is automatically read and recorded. The barcode can be used for sample management and usage history management of sample tubes.
In addition to the leak test results, the function to record the temperature of the tube, trap and flow rate will support tracing of the cause of the abnormal result.
The internal standard sample addition function of TD-30R adds a gaseous standard substance to the sample tube to improve the reliability of the measurement result.It has a fixed addition mode using a heated sample loop and an addition amount variable mode using a mass flow controller.
2 types of Internal Standard Addition
Bar code reader
Pre treatment result browser
D8-Toluene 1ppmadd. 20mL/min×0.2minRSD%<2
Robustness and Easy maintenance
TD of cap attaching / detaching type is easy to handle but there was a risk of glass tube breakege. TD-30 prevents tube troubles by newly designed tube protection mechanism.
The TD-30 series has been designed to enable Trap tube and O-ring, rotor of valve replacement and other maintenance work to be performed easily from the top of the instrument.The joint of the capillary column places in the column oven of the GC and it is easy to install.Consumable Usage Counter records the number of uses for each part and reports when it reaches a set number, so it is possible to prevent troubles due to the lifetime of parts. This superior design minimizes downtime during maintenance and improves laboratory productivity.
Tube protection
Easy maintenance
By releasing the pressure before the tube release, it prevents the adsorbent and holding material from moving.
Pressure release
Trap
Column joint
O-ring
Consumable usage counter
Rotor
Usability
The control software of TD-30 is very easy to learn the operation method by the same user interface as GC, GC-MS method, batch file setting screen and look and feel.It is also possible to add or interrupt samples during batch processing.
Flexibility
If the operator forgets to place a tube in the sample tray or a leak error occurs due to an improperly sealed tube, the system allows the operator to select whether to stop the continuous analysis or skip the applicable tubes. That helps prevent wasting valuable time because of simple mistakes.It also allows the operator to select the actions to take in the event the barcode reader fails to read a tube.
Ease of Use
Convenient tools
An independent leak check function can be used for checking after maintenance and checking the state of the sample tube. By using the trap conditioning function you can lower the background immediately after replacing the trap.
The TD-GC-FID system with wide dynamic range can measure many components at the same time with low running cost.
VOC in Ambient air
11 3-chloro-1-propene12 Dichloromethane13 Acrylonitrile14 1,1-Dichloroethane15 cis-1,1-Dichloroethene16 Chloroform17 1,1,1-Trichloroethane18 CarbonTetrachloride19 Benzene20 1,2-Dichloroethane
31 m+p-xylene32 o-xylene33 Styrene34 1,1,2,2-Tetrachloroethane35 1,3,5-Trimethylbenzene36 1,2,4-Trimethylbenzene37 m-Dichlorobenzene38 p-Dichlorobenzene39 Benzylchloride40 o-Dichlorobenzene41 1,2,4-TrichlorobenzeneIS d8-Toluene
Work space air
2.0 3.0 4.0 5.0 6.0 min
GC-2030AF + TD-30
It takes high cost to re-measure if atmospheric measurement fails in analysis. It is possible to lower the risk of failure of analysis by using the TD-30R restore and internal marking function.
1 Freon122 Freon1143 Chloroethene4 Chloromethane5 1,3-Butadiene6 Bromoethane7 Chloroethane8 Freon119 1,1-Dichloroethene10 Freon113
21 Trichloroethene22 1,2-Dichloropropane23 cis-1,3-Dichloropropane24 Toluene25 trans-1,3-Dichloropropane26 1,1,2-Trichloroethane27 Tetrachloroethane28 1,2-Dibromoethane29 Chlorobenzene30 Ethylbenzene
1st analysis
2nd analysis
Standard 100ng
Indoor Air
Tolu
ene
Hexane
Aceto
nitrile
Eth
ylb
enzene
Xyle
nes
Chemical release
Thermal Extraction
TD-30 with no cold point and short transfer line is ideal for SVOC measurement.Because it has low background, it can be used for trace analysis such as measurement of chemical release gas using chamber and measurement of atmospheric atmosphere in clean room.
VDA 278 of the method of measuring the emission gas of automobile parts, filling the tube with a sample piece, heating it to 100 ° C, measuring the VOC. After removing the sample, heating the tube to 280 ° C and measuring the SVOC on tube.The easy to access designed sample tray of TD-30 is suitable for the application.
Analysis of released gas from rubber
Simultaneous analysis of SVOC standard
VOC(100℃)
SVOC(280℃)
Flavor from foods
Odor from consumables
GCMS-TQ8040 + TD-30R
Sample tray lays the tube horizontally TD-30 is not only solid but also viscous specimen can be set so it is suitable for analysis of aroma components in food.
The TD-30 series supports constant linear velocity carrier gas control by electronic flow controller. Therefore, semi-quantitative / qualitative using the retention index database can be used.
Analysis of cardboard
Retention index alkane
1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0
Met
han
ol
DM
EA
ceti
c ac
idA
ceto
l
Furf
ura
l
D-L
imo
nen
e
Fen
cho
ne
p-A
llyl a
nis
ole
An
is a
ldeh
yde
Hyd
roxi
l met
hyl
fu
rfu
ral
An
eth
ole
An
is k
eto
ne
オーブン温度
保温バイアル数 最大12本オーバーラップ保温可能
TD-30seriesThermal Desorption System
Tube Dimension O.D.1/4‘ (6.35mm) L 3.5’(89mm)
Tube Desorb Temperature Setting: 0 to 430℃(in 1℃ unit) Control:Room temperature+15 to 430℃(accuracy of ±1℃)
Tube Desorb Flow Setting: 20 to 200mL/min(in 1mL/min unit, accuracy of ±2mL/min)
Tube Desorb Time Setting: 0 to 240min(in 0.01min unit)
Trap Dimension O.D.1/8’(3.2mm)I.D.2mm L 102mm Silconert2000 Deactivated SUS tube
Trap Adsorbent TenaxTA 60-80mesh(60mg) StandardCarbopack(50mg)+Carbosieve(10mg) OptionalCarboxene1000(70mg) Optional
Trap Desorb Temperature Setting: 0 to 350℃(in 1℃ unit)Control:0~350℃(accuracy of ±1℃)
Trap Cooling Temperature Setting: -40 to 80℃(in 1℃ unit) Control:Room temperature-50℃ to 80℃(Valve Temp.<250℃), Room temperature-45℃ to 80℃(Valve Temp.>250℃)accuracy of ±1℃
Split Ratio 1:5 to 1:200
Sample Path Silconert2000
Switching Valve 6 port 2 position high temperature Valve with Electric Actuator
Joint Temperature Setting: 0 to 300℃(in 1℃ unit) Control:Room temperature+15℃ to 300℃(accuracy of ±1℃)
Valve Temperature Setting: 0 to 300℃(in 1℃ unit) Control:Room temperature+15℃ to 300℃(accuracy of ±1℃)
Transfer Line Temperature Setting: 0 to 350℃(in 1℃ unit) Control:Room temperature+15℃ to 350℃(accuracy of ±1℃)
Internal Standard Addition(TD-30R) Fixed Volume:0.5mL,Variable Volume:4mL to 2000mL
Dry Purge(TD-30R) Temperature Setting: -40 to 140℃(in 1℃ unit) Control:Room temperature-50℃ to 140℃(Valve Temp.<250℃),Control:Room temperature-45℃ to 140℃(Valve Temp.>250℃) accuracy of ±1℃、Flow:20 to 200mL/min(in 1mL/min unit),Time:0 to 30min(in 0.01min unit)
Carrier gas High-purity helium, nitrogen, Electronic control via Advanced flow controller (AFC) built into GC
Purge gas High-purity helium, nitrogen, Electronic control via mass flow controller (MFC) built into TD-30 series
PC Interface USB
Control Software TD Control Software
Software Operating Environment Microsoft Windows 7/10 (64/32Bit)
Guaranteed Operating Environment 13 to 33 °C, humidity 20 to 70 % RH (performance guaranteed at 18 to 28 °C)
Power Supply MAX1200VA
Dimensions TD-30R:720(W)470(H)690(D)mm, TD-30:580(W)470(H)550(D)mm
Weight 49kg(TD-30R), 48kg(TD-30)
Model Capacity Restore Dry Purge
ISTD addition
TD-30R 120 tubes 〇 〇 〇
TD-30 60 tubes
Dimensions (TD-30R GCMS-QP2020)
Specification and installation condition
TD-30R TD-30
1580
470
590