Download - thiet ke inverter
-
8/7/2019 thiet ke inverter
1/56
PROJECT REPORT
INVERTER DESIGN FOR 2001 FUTURE ENERGY
CHALLENGE
College of Engineering and Computer Science
University of Central Florida
Orlando, FL 32816
Tel (407) 823-0185Fax. (407) 823-6334
Student Team Members :
Joy Mazumdar
Manasi Soundalgekar
Duy Bui
Nancy Saldhana
Bassem Khoury
Steven Pugh
Advisor: Dr. Issa Batarseh
15th
June, 2001
Return to Main Document
-
8/7/2019 thiet ke inverter
2/56
Signature Page
The following students comprised the Future2001 EnergyChallenge team from the
University of Central Florida under the guidance of Dr Issa Batarseh.
Advisor :
( Dr Issa Batarseh ) Date
Students :
( Joy Mazumdar )
( Manasi Soundalgekar )
( Duy Bui )
( Nancy Saldhana )
( Bassem Khoury )
( Steven Pugh )
Power Electronics group at the University of Central Florida wishes to thank IEEE
PELS, DOE and the other organizers of Future 2001 Energy Challenge Competition
for providing its students the opportunity to participate in this project.
-
8/7/2019 thiet ke inverter
3/56
-
8/7/2019 thiet ke inverter
4/56
2.10 Component values for 10kW inverter system
3.0 Manufacturing Issues3.1 Electrical mounting and termination3.2 PCB trace selection3.3 Heat sink issues3.4 Wiring considerations
4.0 Educational Impact4.1 About UCF4.2 Power Electronics progress at UCF4.3 Student participation in the project4.4 Project development stages4.5 Educational benefits
5.0 Inverter Operating Instructions6.0 Simulation results and experimental setup7.0 Cost Evaluation Spreadsheet8.0 References9.0 Appendix
A.DSP Sampling cycleB. ORCAD schematic for PCB layoutC.Pspice schematic circuit for 1.5kW and 10kW inverter systemD.Devices and IC datasheets
-
8/7/2019 thiet ke inverter
5/56
List of figures:
Fig1 (a) Block diagram of the proposed inverter system, (b) Circuit diagram of the proposed
inverter
Fig2 Flat-topped pulse current
Fig3 (a) Half-bridge Inverter under resistive load, (b) Switching and output voltage waveform
Fig4 (a) Half-bridge with inductive- resistive load, (b) Equivalent circuit, (c) Steady state
waveforms
Fig5 SPWM and Inverter Output Voltage
Fig6 Single SPWM pair of pulses
Fig7 Inverter control scheme
Fig8 (a)Waveforms for correction of dead time, (b) Inverter leg
Fig9 Input protection circuit
Fig10 RC Snubber Circuit
Fig11 Thermal resistance
Fig12 Power panel schematic
Fig13 Differential Voltage and current waveform under normal resistive load
Fig14 Phase 1 and Phase 2 voltage waveform
Fig15 DC positive and negative bus voltage
Fig16 Maximum voltage stress across switches MOSFET1, MOSFET2, IGBT1, IGBT2, IGBT3
and IGBT4
Fig17 Load current waveform under unbalanced load conditions
Fig18 Output Filter Capacitor voltage waveform under unbalanced load conditions
Fig19 Output Filter Inductor current waveform under unbalanced load conditions
Fig20 Voltage feedback waveform for DSP
Fig 21 Current feedback waveform for DSP
Fig 22 Voltage and current waveforms for 10kW system
-
8/7/2019 thiet ke inverter
6/56
1
1.0 Introduction
In this report, a design for a high power density 10kW inverter circuit is presented for conversion of
energy from DC fuel cells to AC power to be used mainly for domestic utility applications. The
configuration is achieved using a high frequency dc-dc push-pull converter at the input side followed by a
full-bridge PWM inverter and a low-pass filter at the output side. Due to the simplified power stage and
the application of DSP-based sinusoidal pulse width modulation technique, output voltage Total
Harmonic Distortion (THD) is reduced and a relatively smaller overall inverter size is achieved. The
proposed practical circuit operates from a 48V DC fuel cell input and outputs a regulated 120V AC, 60Hz
sinusoidal voltage having3-wire configuration[4]. A complete circuit analysis, design and cost evaluation
is presented and supported by PSPICE simulation results. As per competition guidelines, a low power
inverter has been redesigned, tested and prototyped, to deliver a 1.5kW load. Operating waveforms,
printed circuit board layout and measured efficiency of the actual circuit are also presented.
2.0 Theory of Design Rationale
This project will explore the possibility of making alternate sources of energy utility interactive by means
of low cost power electronic interface (DC-AC inverter). The constraint towards the above scheme is the
input DC voltage from alternate forms of energy is very rarely stable hence the design of the proposed
interface has to produce an AC output, which is independent of the input fluctuations[3]. The PWM
inverter will be digitally controlled using a commercial DSP chip for AC voltage and frequency
regulation. The implementation of the DSP will have a current controller, voltage controller and a feed
forward controller. The input voltage from the renewable forms of energy will be 48VDC with fluctuation
limit of 42-72V DC. The output voltage will be 110/220VAC @60Hz clean sine wave suitable for home
applications. Since the inverter is for residential use, low cost, high reliability and safety are essential
design issues.
2.1 Design Specifications for the 1.5kW prototype [1]
Input Voltage Range : 42-72 VDC
Output Voltage : Single-phase 120/240VAC RMS, 3-wire output
-
8/7/2019 thiet ke inverter
7/56
2
Push-Pullstage
DC-DC
InverterStageAC-DC
Low-PassFilter
+
dcV acv
dcI
aci
Output Frequency : 60Hz 0.1Hz
Output Power Range : 2 x 750Watts continuous
Efficiency : > 90%
Line and Load regulation : 5%
Total Harmonic Distortion : < 5%
Input Current limit : 55 Amps
Switching Frequency : 50kHz for push pull and 15kHz for inverter bridge
Operating temperature : 10 C - 40 C
DSP Controls : TMS320F240 Evaluation module
Communication Interface : RS232
2.2 DC-DC Converter Stage Design [14]
A block and circuit diagram for the proposed inverter implementation is shown in Fig. (a) and the circuit
schematic is shown in Fig 1(b).
Fig 1(a): Block diagram representation of the proposed inverter system
Fig 1(b): Circuit diagram of the proposed inverter system
1
1D
2D
3D
4D
1R
2R
1L
2L
C1
C2
Q1 Q2
Q3 Q5
Q4 Q6
L3 L4
C4
Load Load
Load
50kHz 50kHz
15 KHz 15 KHz
15 KHz 15 KHz
Fuel
Cell
n1
n1
n2
n2
C3
T1
iTr
Vdc
Iac
Vac
Cin
R3
R4
-
8/7/2019 thiet ke inverter
8/56
3
To reduce the size of the system transformer, the first stage will consist of a high frequency push-pull dc-
dc converter. The second stage consists of two half-bridge inverters arranged in a full bridge
configuration. The control technique used in the second stage is sinusoidal PWM. The third stage
represents the low pass filter with passive components, due to the relatively high attenuation of the low
harmonic components for the output voltage waveform. The input stage consists of power devices Q1
and Q2, transformer T1, inductor L1, L2 and dc bus capacitors C1 and C2. The dc push-pull converter
boosts the bus voltage to 240VDC for the inverter to produce 110VAC. The output inverter stage
consists of power devices Q3 - Q6, output inductors L3, L4 and capacitors C3 and C4. Using the well-known
sinusoidal PWM technique, this circuit generates a sine wave output voltage.
2.2.1 Basic Circuit Operation of DC-DC stage
The push pull converter belongs to the feed-forward converter family. With reference to Fig. 1(b), when
Q1 switches on and Q2 is off, current flows through the 'upper' half of T1's primary and the magnetic field
in T1 expands. The expanding magnetic field in T1 induces a voltage across T1 secondary, the polarity is
such that D2, D4 is forward biased and D1, D3 is reverse biased. D2 conducts and charges the output
capacitor C2 via L2 and D4 conducts and charges the output capacitor C1 via L1. The components L1, L2
and C1, C2 form a LC filter network. When Q1 turns off, the magnetic field in T1 collapses, and after a
period of dead time (dependent on the duty cycle of the PWM drive signal), Q2 conducts, causing the
current to flow through the 'lower' half of T1's primary and the magnetic field in T1 expands. Now the
direction of the magnetic flux is opposite to that produced when Q1 conducted. The expanding magnetic
field induces a voltage across T1 secondary, the polarity is such that D1, D3 are forward biased and D2, D4
are reverse biased. D1 conducts and charges the output capacitor C1 via L1 and D3 conducts and charges
the output capacitor C2 via L2. After a period, Q1 conducts and the cycle repeats.
There are two important considerations to be made when it comes to the design of the push - pull
converter:
-
8/7/2019 thiet ke inverter
9/56
4
1. Both transistors must not conduct simultaneously, as this would effectively short-circuit the
supply. Hence, the conduction time of each transistor must not exceed half of the total period for
one complete cycle; otherwise, the conduction will overlap.
2. The transformer magnetic flux must be bi-directional; otherwise the transformer may saturate,
and cause destruction of Q1 and Q2. This requires that the individual conduction times of Q1 and
Q2 are exactly equal and the two halves of the center-tapped transformer primary be magnetically
identical.
These design considerations must be handled by the control, drive circuit and the transformer.
The average output voltage, Vout, equals the average of the waveform applied to the LC filter:
2 1 21
out in S on,sw on,swn
V V f ( T T )n
= + (1)
where,
outV = Average output voltage - Volts
inV = Average supply voltage - Volts
2n = number of secondary turns of the center -tap transformer T1
1n = number of primary turns of the center -tap transformer T1
Sf = Switching frequency of MOSFETs Q1 and Q2 - Hertz
1on,swT = on time period of Q1 Seconds
2on,swT = on time period of Q2 Seconds
The control circuit monitors and controls the duty cycle of the drive waveforms to Q1 and Q2. If inV
increases, the control circuit will reduce the duty cycle accordingly, so as to maintain a constant output.
Likewise, if the load is reduced and outV rises the control circuit will act in the same way. Conversely, a
decrease in inV or increase in load will cause the duty cycle to be increased. Following given is the
derivation of all the inverter parameters.
-
8/7/2019 thiet ke inverter
10/56
5
Relations between primary current, output power, and input voltage:
Since the maximum average input power Pin is 1.8kW and if we assume the efficiency of the push-pull
converter to be 90%, then the average output power Pout of the DC-DC stage is 1.65kW.
0 9out inP . P= (2)
It can be seen that, the average input power may be given as,
0 5in DCmin pft
P V ( . I )= (3)
where DCminV is the minimum DC input voltage, 0.5 is the duty cycle and pftI is the flat-topped pulse
current as shown in Fig (2). The flat-topped pulse current is defined as ramp on a step. The flat-topped
pulse current appears at the transformer center tap.
Fig 2: Flat-topped pulse current
The relationship in Equation (3) is valuable since, it gives the equivalent peak flat-topped primary current
pulse amplitude in terms of what is known at the outset, the minimum DC input voltage and total input or
output power. This value is needed to help us select the MOSFET. Finally, for the MOSFET selection the
maximum voltage stress that the MOSFET has to handle should be known.
Maximum voltage stress of the MOSFETs:
It can be shown that the maximum voltage stress across the MOSFET is given by the following formula,
1 3 2ms DCmaxV . ( V )= (4)
where DCmaxV is the maximum input DC voltage.
The maximum stress voltage is 30% above twice the maximum DC input voltage. Maximum stress
comes from the so-called leakage inductance spikes, these come about because there is an effective small
t
iTr
Ipft
-
8/7/2019 thiet ke inverter
11/56
6
inductance (leakage inductance) lL in series with each half primary. At the instant of turnoff, current in
the MOSFET falls rapidly at ratedt
dicausing a positive-going spike of amplitude
dt
diLE lls = at the bottom
end of the leakage inductance. The leakage spike may be as much as 30% more than twice the maximum
DC input voltage.
Using the given design specifications, we carry on with the following stress voltage calculations.
0 5in DCmin pft
P V ( . I )=
1 11
0 5out
pft
DCmin
( . P )I
. V= = 87 amps at 50% duty cycle (5)
RMS pft
I I D= = 61 amps at 50% duty cycle (6)
1 3 2rms DCmaxV . ( V )= = 187 Volts at 50 % duty cycle
MOSFET Conduction losses
0 40 4 0624 outDC pft on pft on
DCmin
P( . T )P I V . I V .
T V= = = (7)
MOSFET Switching losses
2 2 3 122 2
pft SDCmax S out DCmax St(ac) pft dc
DCmin
I TV T P V T P I V .T T V T
= + = (8)
where,
ST = vr cf t t= is the transition time.
vrt = voltage rise time from 0 to 2 DCmaxV .
cft = current fall time from
pftI to 0
The total MOSFET loss consists of switching losst (a c )
P and conduction loss DCP and is given by
min
max
min
)(
624.012.3
DC
outsDC
DC
outdcacttotal
V
P
T
TV
V
PPPP +=+= (9)
-
8/7/2019 thiet ke inverter
12/56
7
2.2.2 Design of transformer stage for DC-DC[15]
The push-pull DC-DC converter design is one of the most critical issues in this project. The detailed
design is explained as below based on the following design parameters:
48nomV V= (nominal input dc voltage)
42minV V= (minimum input dc voltage)
72maxV V= (maximum input dc voltage)
240outV V= (dc bus voltage)
6outI A= (dc current)
50Sf kHz= (push-pull switching frequency)
0 13mB . T = (maximum operating flux density)
90% = (efficiency)
0 4uK .= (window utilization factor)
1dV = (diode voltage drop)
0 5maxD .= (maximum duty cycle)
25orT C= (maximum temperature rise)
Skin depth of the wire is in cm
6 62
S
.
f
= (10)
0 03. = cm
Wire diameter is 2
2 0 059D .= = cm
Bare wire area is wA in sq cm
23
2 754 104
w
DA .
= = cm2 (11)
Based on wA calculated above, choose wire size AWG 23, heavy insulation copper wire
Output Power Pout of the converter is given by
out out out d P I (V V )= + (12)
1446outP watts=
-
8/7/2019 thiet ke inverter
13/56
8
The total apparent power is Papp in VA is given by
22
app out P P ( )= +
(13)
4317appP VA=
Electrical coefficient eK
Here we havef
K and acB given by,
4f
K = (waveform coefficient for square wave)
0 3ac maxB . B=
The electric coefficient, eK , can be obtained from the following relation,
2 2 2 40 145 10e f S sc
K . K f B = (14)
resulting in the following value of eK
882 18eK .=
Based on Kg, we select our core. Kg is given by,
2t
g
e
PKK= (15)
2 447g
K .= cm5
Selection of Core
Based on the value of core geometry, ferrite core from Magnetics Inc, OP 45530-EC is a suitable E core
for the above application. The PC bobbin used is PC-B5530-FA.
Datasheet of OP 45530-EC Core:
H W L G MPL Wtfe Wtcu MLT Ac Wa Ap At Perm ALcm cm cm cm cm gms gms cm cm2 cm2 cm4 cm2 mH
5.51 4.59 5.48 3.70 12.3 255 172.1 12.2 4.130 3.956 16.339 147.2 2300 564
The core geometry of the above core is 2.206504 cm5. AL is defined in mH/1000. For more informationrefer to [15].
-
8/7/2019 thiet ke inverter
14/56
9
Primary turns Np
It can be shown that Np is obtained from the following relation.
410min
p
S C m f
VN
f A B K
= (16)
3 911p
N .=
To avoid the possibility of core saturation, we choose 6 turns for the primary winding. Under normal
operating conditions, the input current is assumed to be around 40A. The worst case input current is 55A.
Assuming a current density of 450A/cm2, the primary wire bare area is calculated as,
40
450
max
wp
DA = (17)
0 063wp
A .= cm2
For the primary winding, choose 3 strands of AWG 14 heavy insulation copper wire.
Secondary turns Ns
11
100
p out d
S
min
N (V V )N ( )
V
+= + (18)
22 668SN .=
33 turns for were selected for secondary. Under normal operating conditions, the DC output current is
assumed to be around 6A. Assuming a current density of 450A/cm2, the primary wire bare area is
calculated as,
450
out max
ws
I DA = (19)
3
9 428 10wsA .
= cm2
For the secondary winding, 3 strands of AWG 23 heavy insulation copper wire were chosen.
2.2.3 Output inductor design of DC DC stage
This inductor is required since the input is a voltage source and the DC capacitors also act as a voltage
source. Hence, the inductor acts as a current link between two voltage sources. For the purpose of charge
-
8/7/2019 thiet ke inverter
15/56
10
and voltage balancing in the DC capacitors, we require a coupled inductor. The inductance value can be
calculated based on the MOSFET switching frequency and duty cycle as given by,
2out
S o
DVL
f I=
(20)
where D = 0.5 , L1=L2=L. L1 and L2 are the coupled inductors. Vout is the average output voltage, fs is the
switching frequency, Io is the output current ripple (assume to be 10% of output current). Based on 1:5
transformer ratio, i.e. output voltage of the push- pull is 240V, and using 750W power rating for each
stage, L = 2 mH. The inductor was constructed using a powder iron core (26 material).
Construction of the coupled inductor[15]
The selection of the core was based on the following two main design parameters
Inductance L required with DC bias = 2mH DC current = 6A
Based on the calculation of the product LI2, Micrometals E220-26 iron powder E core was found suitable.
Datasheet of E 220-26 E core:
H W L G MPL Wtfe Wtcu MLT Ac Wa Ap At Perm ALcm cm cm cm cm gms gms cm cm2 cm2 cm4 cm2 mH
5.54 3.86 5.61 3.83 13.2 333.9 167.9 11.6 3.6 4.079 14.684 141.3 75 275
The core geometry of the above core is 1.827264 cm5. AL is defined in mH/1000.The required number of turns, N, can be calculated as
310L
LN
A= (21)
N=85.28 turns
where, LA =mH/1000turns and L=inductance in mH.
We have chosen N=90 turns for the required inductance.
For calculation of the wire size, the bare wire area required @ 450A/cm2, Awb, is obtained from,
450
outwb
I DA = (22)
Awb = 0.0094 cm2
-
8/7/2019 thiet ke inverter
16/56
11
Hence AWG 18 heavy insulation copper wire is suitable for the inductor. Since the inductor is coupled,
the construction requires 2 strands of AWG 18 wire wound 90 times inside a pair of E220-26 core.
2.2.4 Design of DC bus capacitors
It is assumed that all the energy for the inverter is supplied by the DC capacitor bank. The ripple
frequency at the DC capacitor will be twice the switching frequency, i.e. 100kHz. These are bulk
capacitors and the ripple voltage across it is assumed to be 1% of maximum value. The value of the
capacitors can be calculated using the following formula,
2 2
1 2
2
2out
S
PC
( f )(V V )=
(23)
where
1V=max ripple capacitance voltage
2V = min ripple capacitance voltage
The DC bulk capacitors are chosen to be 560uF/ 500V.
2.3 PWM DC-AC Inverter Stage Design[14]
Since the inverter is the most important aspect in this design, a detailed steady state analysis is presented
for the half bridge inverter topology, which is used in our circuitry. The analysis presents the equations
and supporting waveforms.
2.3.1 Basic half-bridge inverter circuit resistive load
To illustrate the basic concept of a dc-to-ac inverter circuit we consider a half-bridge voltage-source
inverter circuit under resistive load as shown in Fig. 3 (a). Its switching waveforms for S1, S2 and the
result output voltage are shown in Fig. 3 (b).
-
8/7/2019 thiet ke inverter
17/56
12
Fig.3 (a) Half-bridge Inverter under resistive load.(b) Switching and output voltage waveform.
The circuit operation is very simple since S1 and S2 are switched on and off alternatively at 50% duty
cycle as shown in the switching waveform in Fig. 3 (b). This shows that the circuit generates a square ac
voltage waveform across the load from a constant dc source. The voltages, Vdc and Vdc are across R
when S1 ON while S2 OFF and when S2 is ON while S1 is OFF, respectively. One observation to be
made here is that the frequency of the output voltage is equal to f = 1/T and is determined by the
switching frequency. This is true as long as S1 and S2 are switched complementarily. Moreover, the rms
value of the output voltage is simply Vdc. Hence, to control the rms value of the output voltage we must
control the rectified Vdc voltage source. Another observation is that the load power factor is unity since
we have purely resistive load. That is rarely encountered in practical application.
(b)
S1
S2
o
+Vdc
-Vdc
t
T
T/2
(a)
R
S1Vdc
S2
iO
Vdc
o
+ -
-
8/7/2019 thiet ke inverter
18/56
13
Finally, we should note that in practice the above circuit does not require two equal dc voltage sources as
shown in Fig. 3 (a). Instead, large splitting capacitors are used to produce two equal dc voltage sources.
The two capacitors are equal and very large so that RC is much larger than the half-switching period. This
will guarantee that the mid-point, a, between the capacitors has a fixed potential at one-half of the supply
voltage Vdc.
2.3.2 Inductive-Resistive load
Figure 4 (a) shows a half-bridge inverter under inductive resistive load with the equivalent circuit and the
output waveforms shown in Fig. 4 (b) and (c), respectively.
Fig. 4 (a) Half-bridge inverter with inductive resistive load.
(b) Equivalent circuit and (c) Steady state waveforms.
a
a'
(b)
t
in
o
+
-
in+Vdc
-Vdc
T/2 T0
t
iL
IL(T/2)
IL(0)D1 D2
Q1Q2
tT/2 T0
t1
(c)
R
Vdc
iO
o
L
Vdc
+-
D1Q1iD1
iD2
Q2 D2
(a)
-
8/7/2019 thiet ke inverter
19/56
14
With Q1 and Q2 switched complementary each at 50% duty cycle with switching frequency f , then the
load between terminal a and a is excited by square voltage waveform )(tvin of amplitudes
dcV+ and dcV as shown in Fig. 5 (b), i.e. )(tvin is defined as follows:
-
8/7/2019 thiet ke inverter
20/56
15
pulses increases when the control period decreases or its frequency, fs, increases. K is the number of Ts
periods in one half of the output period, To. The frequency of the reference signal sets the frequency of
the output voltage fo. It can be noticed as the magnitude modulation index, M, varies from 0 to 1, the
width of each pulse varies from 0 to / k, i.e.
2
os
TkT =
os ff
k
2
1=
=
o
s
f
fk
2
1
The ratio between the carrier frequency and the output frequency is known as Frequency Modulation
Index, fM , defined as
o
s
f f
fM
=(25)
Hence, k is given by, fMk2
1= (26)
Notice that when k = 1, it is a special case where fM = 2.
Sinusoidal PWM Waveforms
In Sinusoidal Pulse Width Modulation, SPWM, multiple pulses are generated, each having different
width time. The width of each pulse is varied in proportion to the instantaneous integrated value of the
required fundamental component at the time of its event. In other words, the pulse width becomes a
sinusoidal function of the angular position. The repetition frequency of the output voltage will be a
frequency higher than the fundamental. In applying SPWM, the lower order harmonics of the modulated
voltage wave are highly reduced in contrast to the use of uniform pulse width modulation.
In SPWM the output voltage signal can be obtained by comparing a control signal, contv , against a
sinusoidal reference signal, refv , at the desired frequency as shown in Fig 5. At the first half of the output
period, output voltage takes a positive value (+ dcV ), whenever the reference signal is greater than the
-
8/7/2019 thiet ke inverter
21/56
16
control signal. At the same way, at the second half of the output period, the output voltage takes a
negative value (- dcV ) whenever the reference signal is less than the control signal.
The control frequency contf determines the number of pulses per half of cycle for the output voltage
signal. Also, the output frequency of is determined by the reference frequency reff . The modulation
index Ma is defined as the ratio between the sinusoidal magnitude and the control signal magnitude.
contp
refp
aV
VM
,
,= (27)
To obtain a vary train of pulses, each pulse has to vary proportional to the necessary fundamental
component precisely at the time when this pulse occurs. The frequency of the output waveform needs to
be higher than the frequency of the fundamental component. By varying the width of each pulse, the
inverter is able to produce different levels of output voltage for the corresponding pulse event.
2
2
)(tvo
wt
wt
contpV
,
refpV ,
dcV
dcV
)(,
tvrefp
)(,
tvcontp
oT
reff
1
contf
1
Figure 5. SPWM and Inverter Output Voltage.
-
8/7/2019 thiet ke inverter
22/56
17
Calculation of the output voltage as Fourier series expansion
The calculation of the SPWM output voltage is the same as it was done with UPWM output voltage.
However, for SPWM the width of each pulse varies according to its position. The expression for the
output voltage is obtained using a Fourier series transformation for ov , given by,
=
++=2,1
)sincos()(n
nnoo nwtbnwtaVtv (28)
Since the inverter output voltage is an odd function, only odd harmonics exist.
The calculation the output voltage harmonic components can be done using one single pair of pulses as
shown in Fig 6.
2
)(tvo
t
dcV
dcV
oT
i i'
+i +i'
wi
wi
Figure 6 Single SPWM pair of pulses.
{ }{ })(cos)(cos)(cos)(cos
|)cos(|)cos(
)()sin()()sin(
)()sin()()sin(1
)()sin()(1
,
,
,
,
2
0
,
++++++=
=
=
+=
=
++
+
+
++
+
+
++
+
+
iwiiiwiiDC
in
DC
in
DCin
DCDCin
oin
nnnnn
VV
nwtnwtn
V
V
wtdnwtwtdnwtV
V
wtdnwtVwtdnwtVV
wtdnwtwtvV
wii
i
wii
i
wii
i
wii
i
wii
i
wii
i
Using this trigonometric relationship:
+=
2sin
2sin2coscos
yxyxyx
-
8/7/2019 thiet ke inverter
23/56
18
Factoring through, we obtain the harmonic component for a single pair of pulses,
++
+
=
2sin
2sin
2sin
2,
wii
wii
wiDCin nnn
n
VV
Adding the contribution from all other pulses, the ith component of ov is given by,
=
++
+
=k
i
wii
wii
wiDCn nnn
n
VV
1 2sin
2sin
2sin
2
where, i is the starting angle of the ith pulse, and wi is the pulse width at the corresponding angular
position. Next we estimate w for each ith pulse.
Inverter controller scheme is shown in Fig. 7 [10].
Figure 7:Inverter control scheme
The inverter modulates a dc bus voltage, Vdc, into a cycle-by-cycle average output voltage. The amplitude
of the inverter output voltage is directly proportional to the commanded duty cycle of the inverter and the
amplitude of the dc bus voltage Vdc. It can range from + Vdc to - Vdc. Current mode control is used for this
PWM inverter. Current mode control is a two-loop control system that simplifies the design of the outer
PI 1 PI 2PWM1
PWM2
ADCIN
ADCIN
GATEDRIVE
Voltageand
currentsense
amplifier
+
_
+
_
IoutVout
Vdc
C1
C2
Vdc
Vdc
+
+
S1
S2
OFF
PWM Lb
Io
Vo
Co RL
Verr
TMS320F240EVM
-
8/7/2019 thiet ke inverter
24/56
19
voltage control loop and improves UPS performance in many ways, including better dynamics and a feed
forward characteristic that could be used to compensate DC bus ripple and dead-time effect, etc.
2.3.4 The Output Voltage
It can be shown that the average output voltage over ST period is given by,
10.,
-
8/7/2019 thiet ke inverter
25/56
20
Fig 8: Waveforms for correction of dead time
The desired Tn for both directions of current is illustrated in the diagram and is generated by
Positive sawtooth edge
compare sawtooth with Vph for i>0 ; compare sawtooth with Vph- for i0 ; compare sawtooth with Vph for i
-
8/7/2019 thiet ke inverter
26/56
21
The source DC voltage is ripple free
All power devices behave ideally
The load is linear
Series resistance of the capacitance is negligible
As the exact voltage drop across the filter inductance is difficult to determine, it is assumed negligible.
Thus, rms inverter output voltage is equal to the rms load voltage based on this assumption, the
modulation index can be calculated as
d
o
E
Vd 2= (32)
From the value of the modulation index, the constant K, which has been derived from the Fourier analysis
of the output voltage, can be calculated as given below.
2
1
6542
14404
5
5
64
4
15
+=
dddd
K (33)
The optimum value of the filter inductance can be calculated as
+=
2
1
,
22
,
41avgor
d
S
r
avgor
d
So
of
V
EK
f
f
V
EK
fI
VL (34)
From the value of the filter inductance, the filter capacitance can be calculated as
avgorSf
df
VfL
EKC
,2
= (35)
where,
dE is the input DC voltage to the inverter stage , oV is the output rms voltage , avgorV , is the average
output voltage , rf is the fundamental output frequency , Sf is the switching frequency , fL is the filter
inductance , fC is the filter capacitance
-
8/7/2019 thiet ke inverter
27/56
22
Using the value of dE to be 240V and the output RMS voltage to be 120VAC, we find the value of
required L to be 1.7mH and the value of capacitance to be 4.7uF. These values give the corner frequency
of the LC filter to be 1.7kHz. As far as the corner frequency selection is concerned, since we are
regulating the low frequency current and voltage, we need to filter out the high frequency content. Given
that the switching frequency is 15kHz, the corner frequency should be 10-20 times lower than that
(~1.5kHz) to be able to extract the fundamental frequency. On the other hand, we do not want to attenuate
the fundamental frequency (60Hz). So, we need a need a corner frequency of 10 times higher than that
(~600Hz). Given these constraints, the corner frequency should be 600Hz. Half way in
between will gives ~1kHz corner frequency. This does approximately match with the range of value,
which we derived from the theoretical calculations. Hence, we choose the filter inductance value to be
2mH and the capacitance value to be 17.5uF.
2.5 Input Circuits, filtering, fusing and transient protection
Input Filtering
Capacitors C1, C2, C3 and Balun transformer T1 form an input Balun filter [13]. A Balun filter is used to
attenuate common mode noise generated by the converter and reflected back onto the power bus. The Pi
() filter, which will suppress differential mode noise. The filter components are chosen such that it
presents the highest impedance at the converter switching frequency. The inductance value of the Balun
transformer chosen is 8uH. This is manufactured by using 10 turns of AWG 18 heavy insulation copper
wire wound on E220-26 micrometals iron powder core. The value of the capacitors chosen is
220uF/100V. Practically speaking, this type of filter can reduce noise levels by about 10 to 12 dB.
Input Fusing
As a general rule, the input lines to any power converter should be fused. The fuse will limit input power
in the event of a catastrophic failure within the converter or the system the converter is supplying power
to. The chosen fuse should be a slow-blow type with a current rating approximately 200% of the full load
input current to the converter (for wide input range converters, 200% of the maximum input current must
-
8/7/2019 thiet ke inverter
28/56
23
be used). Having a slow-blow type will allow the converter short circuit protection circuitry time to react
to transient fault conditions. For our application, an 80A fuse semiconductor fuse is chosen for input
protection.
Input Transient Protection
The avalanche Zener D2, clamps the input to a safe level in the event of a power line transient. The
energy contained within the transient is dissipated across the surge suppresser.
Fig 9: Input protection circuit and output filter
2.6 Output Overload protection
Although the use of filtering will prevent excessive current at power ON, under normal conditions, the
best way to prevent overload at output is to use a fuse with sufficient tolerance to inrush current, so that it
won't blow at power ON. A 15A semiconductor fuse is selected for the output phases.
2.7 DSP Control Design[2,5,6,10]
Todays low-cost, high-performance DSP controllers, such as the Texas Instruments (TI) TMS320F240,
provide an improved and cost effective solution for inverter design. The F240 has integrated peripherals
specifically chosen for embedded control applications. These include Analog-to-Digital converters (A/D),
PWM outputs, timers, protection circuitry, serial communications, and other functions. High CPU
bandwidth and the integrated power electronic peripherals of these devices make it possible to implement
a complete digital control of inverters. Most instructions for the F240, including multiplication and
accumulation (MAC) as one instruction, are single cycle. Therefore, multiple control algorithms can be
+Vin
-Vin
D1
D2
Fuse
C1
+
220nF/100V
C2220nF/100V
+
C3
+
220nF/100V
8uH
8uH
-
8/7/2019 thiet ke inverter
29/56
24
executed at high speed, making it possible to achieve the required highsampling rate for good dynamic
response. This also makes it possible to implement multiple control loops of the inverter in a single chip
and increase integration and lower system cost. Digital control also brings the advantages of
programmability, immunity to noise, and eliminates redundant voltage and current sensors for each
controller. With fewer components, the system requires less engineering time, and it can be made smaller
and more reliable. The extra DSP bandwidth is available for implementing more sophisticated algorithms,
as well as communications to host systems and I/O devices such as LCD displays. DSP programmability
means that it is easy to update systems with enhanced algorithms for improved reliability.
Features of the TMS320F240 System:
The table shown below gives a list of the TI chip parameters and their corresponding values.
Parameter Name TMS320F240EVM
MIPS 20
Frequency ( MHz) 20RAM ( words ) 544
Flash (words ) 16K
Boot Loader available Flash
External Memory Interface Yes
PWM Channels 12
10 bit A-D ( # channels ) 16
Conversion Time (us) 6.1 us
Timers 3
Total Serial ports 2
Features
High-performance Static CMOS Technology
Includes the T320C2xLP Core CPU
Object Compatible with the TMS320C2xx
Source Code Compatible with TMS320C25
Upwardly Compatible with TMS320C5x
132-Pin Plastic Quad Flat Package (PQ Suffix)
50-ns Instruction Cycle Time
-
8/7/2019 thiet ke inverter
30/56
25
Industrial and Automotive Temperature Available
Memory
544 Words 16 Bits of On-Chip Data/Program Dual-Access RAM
16K Words 16 Bits of On-Chip Program ROM ('C240)/Flash EEPROM ('F240)
224K Words 16 Bits of Total Memory Address Reach (64K Data, 64K Program and 64K
I/O, and 32K Global Memory Space)
Event-Manager Module
12 Compare/Pulse-Width Modulation (PWM) Channels
Three 16-Bit General-Purpose Timers With Six Modes, Including Continuous Up and
Up/Down Counting
Three 16-Bit Full-Compare Units with Deadband
Three 16-Bit Simple-Compare Units
Four Capture Units (Two with Quadrature Encoder-Pulse Interface Capability)
Dual 10-Bit Analog-to-Digital Conversion Module
28 Individually Programmable, Multiplexed I/O Pins
Phase-Locked-Loop (PLL)-Based Clock Module
Watchdog Timer Module (With Real-Time Interrupt)
Serial Communications Interface (SCI) Module
Serial Peripheral Interface (SPI) Module
Six External Interrupts (Power Drive Protect, Reset, NMI, and Three Maskable Interrupts)
Four Power-Down Modes for Low-Power Operation
Scan-Based Emulation
Development Tools Available:
Texas Instruments (TITM) ANSI C Compiler, Assembler/Linker, and C-Source Debugger
Scan-Based Self-Emulation (XDS510TM)
-
8/7/2019 thiet ke inverter
31/56
26
Third-Party Digital Motor Control and Fuzzy-Logic Development Support
Sampling Cycle
Eight circuit parameters are sensed and processed by the DSP controller, based on which the control loopfunctions. The circuit parameters are listed as follows:
Input voltage to the converter Vin
Input current Iin
Upper DC capacitor voltage, V+
Upper DC capacitor voltage, V-
Inductor current for bridge leg 1, IL1
Capacitor voltage for bridge leg 1, VC1
Inductor current for bridge leg 2, IL2
Capacitor voltage for bridge leg 2, VC2
The detailed operation of the DSP sampling cycle is explained in the Appendix A.
2.8 Design of heatsinks
The first step in the designing of heat sinks is to determine the total thermal resistance between junction to
ambient and the accordingly determine the thermal resistance of the heatsink. Thermal resistance of a heat
sink can be approximated to
50sa
RA
= (36)
Where Rsa is the thermal resistance of the heatsink and A is the total surface area of the heatsink in cm2.
Based on the selection of the power devices, the area of the heatsinks required can be calculated. For
example, for the MOSFET selected IRFP260N,
Rcs = 0.24oC/W (thermal resistance between case and sink)
-
8/7/2019 thiet ke inverter
32/56
27
Rjc = 0.4oC/W (thermal resistance between junction and case)
Tjmax = 175oC (maximum junction temperature)
Ta = 40oC (Operating ambient temperature)
The relationship between power dissipation and temperature is given by,
jmax a
ja
D
T TR
P
= (37)
where,
PD = 121 Watt (Power dissipation at ambient temperature based on 55A current and RDSON = 0.04)
Rja = 1.116oC/W (thermal resistance between junction and ambient)
The thermal resistance between heat sink and ambient is given by, Rsa ,
sa ja jc csR R R R= (38)
Rsa = 0.476oC/W (thermal resistance between heatsink and ambient )
Therefore, area of the heatsink required based on equation 21 is 10.5 cm 2.
A suitable heatsink is Digikey part no 294-1025-ND. The dimensions of this heatsink are 35.05mm x
6.35mm x 44.45mm. Similarly, the other heatsinks are chosen.
2.9 Design of the RC snubber
Power semiconductors are the heart of power electronics equipment. Snubbers are circuits, which are
placed across semiconductor devices for protection, improve performance and achieve one or more of the
following:
Reduce or eliminate voltage or current spikes
Limit dI/dt or dV/dt
Shape the load line to keep it within the safe operating area (SOA)
Transfer power dissipation from the switch to a resistor or a useful load
Reduce total losses due to switching
Reduce EMI by damping voltage and current ringing
The snubber circuit used is shown in Fig
-
8/7/2019 thiet ke inverter
33/56
28
To achieve significant damping CS > Cp, where Cp is the output capacitance of the switch. A good first
choice is to make CS equal to twice the sum of the output capacitance of the switch and the estimated
mounting capacitance. RS is selected so that RS=V / I . This means that the initial voltage step due to the
current flowing in RS is no greater than the clamped output voltage. The power dissipated in RS can be
estimated from peak energy stored in CS is
2
2
sp
C VE = (39)
This is the amount of energy dissipated in R s when C s is charged and discharged so that the average
power dissipation, Pdiss , at a given switching frequency (fS) is
2diss s SP C V f = (40)
Depending on the amount of ringing the actual power dissipation will be slightly higher than this.
For IRFP 260N, Coss = 603pF and an additional mounting capacitance of 40pF can be considered. Thus
the value of Cs should be 1286 pF. The resistance should be 4.7.
For the IGBT, IRG4BC30UD, output capacitance is 73pF. Hence, snubber capacitance of 200pF is
suitable. The snubber resistance should be 47.
2.10 Important component values designed for 10kw system
Based on the theory, mathematical calculations and simulation results of the 1.5kW inverter design, the
same topology has been extended to 10kW design. The following design values have been obtained.
Maximum voltage stress of the MOSFETs : 250V ; Maximum current stress of the MOSFETs : 329A
Maximum voltage stress of the IGBTs : 500V ; Maximum current stress of the IGBTs : 80A
DC capacitors : 2200uF/450V
Coupled inductor at the output of rectifier : 240uH at 45A
Output Filter Capacitor : 135uF/250V ; Output Filter Inductor : 180uH
For the transformer design, Magnetics Inc, ferrite U type core 49925 is suitable.
-
8/7/2019 thiet ke inverter
34/56
29
3.0 Manufacturing Issues
Presently a laboratory level prototype is being developed at the power electronic laboratory at UCF. For
the purpose of this competition, all the necessary manufacturibility has been addressed to meet the desired
specifications. The most important aspect was meeting the FCC Class A industrial requirements for
conducted and radiated EMI. The FCC ClassA standards considered for design is discussed in Table 1.
Frequency
(MHz)
Radiated Emissions (10m)
V/m
dBV/m
30-88 90 39
88-216 150 43.5
216-960 210 46
>960 300 49.5
Frequency
(MHz)
Conducted Emissions
V
dBV
0.45-1.705 1000 60
1.705-30 3000 69.5
Table 1: FCC Emission Limits for Class A Digital Devices
3.1 Electrical Mounting and Termination
As with any precision electronic device, proper mounting and electrical termination is necessary for the
trouble free and reliable operation of the circuit. Improper electrical termination can cause damage to the
electrical connectors, resulting in the inverter's failure. Improper mounting of the devices can create
stresses (both thermal and mechanical) within the inverter, possibly shortening the operation life of the
device.
3.2 PCB Trace selection
When a component is electrically mounted to a printed circuit board, there are essentially two methods of
actual mounting: soldering the component directly to the printed circuit board, and using a single socket
(or dual socket). Either method has its advantages and disadvantages; however, a socket method of
mounting may be preferred in a field repairable system. Direct soldering has the immediate advantage of
ease of manual mounting; however, it may suffer from service related, and automated assembly
drawbacks.
-
8/7/2019 thiet ke inverter
35/56
30
Not surprisingly, choosing a printed circuit board track size is slightly more complex than choosing a
specific wire gauge, given a particular current. In printed circuit board applications, the maximum
allowable temperature rise of the track becomes an important design consideration. Table 2 is a general
guideline for the current carrying capacity of different external, plated, printed circuit board track sizes
for different temperatures and copper sizes.
Temperature Rise 10oC 20
oC 30
oC
Copper 2 oz 2oz 2 oz
Trace Width (mil) Max Current (A) Max Current (A) Max Current (A)
.010 1.4 1.6 2.2
.015 1.6 2.4 3.0
.020 2.1 3.0 3.6
.025 2.5 3.3 4.0
.030 3.0 4.0 5.0
.050 4.0 6.0 7.3
.075 5.7 7.8 10.0
.100 6.9 9.9 12.5
.200 11.5 11.0 20.5
.250 12.3 20.0 24.5
Table 2: PCB trace selection guideline
As observed from the previous table, printed circuit boards cannot handle large currents unless proper
track width and copper weight is used. (for example, PC Board mounting for the input section carrying
about 40A is only recommended when specific care is taken such as a 3 oz. copper PCB with two 75 Mil
tracks handle the current ). A 10C temperature rise is quite acceptable, however, a 45C temperature rise
is not recommended for continuous use. Track width should be increased to carry the current and reduce
self-heating.
Another important point that requires mentioning concerns the presence of multiple pins for apparently
the same function. In order to eliminate possible damage to the power pins, each pin of the same function
should be externally wired in parallel to spread the current over the required number of pins.
3.3 Heat Sink Issues
The next issue concerning manufacturability is designing of proper heatsinks for the power devices and
ICs. The reliability and longevity of any semiconductor device is (roughly) inversely proportional to the
-
8/7/2019 thiet ke inverter
36/56
31
square of the junction temperature change. Thus halving the junction temperature will result in
approximately 4 times the expected life of the component. The converse is also true! A worthwhile
increase in reliability and component life can be achieved by a relatively small reduction in operating
temperature, since these parameters increase exponentially as temperature is reduced. The whole process
of removing heat from a semiconductor's active area (the die or 'junction') involves many separate thermal
transfers. In order to see a meaningful result, we need a heat-input value and an ambient air temperature.
From these two basic elements, the entire heat flow can be established.
Fig. 10 shows the equivalent circuit for a heat sink illustrating the thermal resistances and junction
capacitors.
The thermal resistance between a transistor junction and the ambient air determines whether a heat sink is
adequate. This thermal resistance is defined as follows:
j A
ja
(T T )R
P
=
where:
jaR = junction to ambient thermal resistance
jT = junction temperature
AT = ambient temperature
P = power dissipation
The thermal resistance of the package is a critical component of the overall thermal resistance, as shown
by the following formula:
ja jc caR R R= +
where:
-
8/7/2019 thiet ke inverter
37/56
32
jcR = junction to case thermal resistance =j CT T
P
caR = case to ambient thermal resistance =c AT T
P
When a heat sink is added to the package, the equation becomes more complex:
ja(HS) jc cs saR R R R= + +
where:
csR = case to sink thermal resistance (this is the resistance of the epoxy, thermal grease, adhesive pad, etc.
that is used to create a thermal bond between the package and the heat sink) = c HSBT T
P
saR = heat sink thermal resistance =HSB AT T
P
HSBT = temperature at the heat sink base
Fig 10: Thermal resistance
An ambient temperature of 25 oC is a good starting point, and provides a safety margin for most domestic
systems, although as we shall see later on, it is important to design for worst case if reliability is to be
maintained. The primary aim of the heatsink design is to ensure that the total thermal resistance is kept to
the minimum possible value, and the entire design process looks at thermal resistance as the primary item
to be calculated. Only after this has been determined can the actual temperature of the transistor junction
be predicted. Aluminum oxide (anodized aluminum) is an excellent electrical insulator, and provides very
good heat transfer, but is fragile and easily damaged. Even a small scratch will generally allow an
Heat
Source
Rth ( j- case) Rth ( case-hs ) Rth (hs-amb)
Cj
Ccase
Chs
-
8/7/2019 thiet ke inverter
38/56
33
electrical short circuit, and obtaining a consistently thick (relatively speaking) layer of oxide is difficult in
the extreme in mass produced heatsink extrusions.
One of the most common mistakes made, is to assume that if a little thermal compound is good, a lot
must be better. Absolutely not so! The amount of thermal compound should be exactly that amount which
ensures that an air-free join is made between the mating surfaces. If too much is applied it will cause an
increase in thermal resistance, since it is not that good at conducting heat. Generally speaking, any
electrical insulator is also a thermal insulator, so the thinner the final composite insulation - including
thermal "grease" - the better. The procedure applied by the students is - Apply a small quantity of the
thermal compound to one finger, then gently rub with the thumb to create an approximately even coating
on finger and thumb. Then rub the thermal compound onto a washer, held between thumb and finger,
ensuring that the coating is just thick enough to be opaque, but thin (and even) enough to ensure that the
contact will be absolute on both surfaces (transistor and heatsink). There is only one thing on a heatsink
that actually gets rid of heat to the surrounding air - surface area. The higher the surface area, the more
heat will be disposed of. Heat is lost to the air by two mechanisms, and both should be maximised for best
performance:
Conduction / Convection
Radiation
Conduction (and / or convection) requires that there is a continuous stream of air flowing past the fins of
the heatsink, which means that the fins should be vertical if at all possible. Horizontally oriented fins will
lose a vast amount of thermal transfer, since the air cannot flow through to the body of the heatsink.
Radiation requires that the surface has the maximum emissivity of heat, and this means that its colour is
important. Matte black heatsinks are the best for radiation, and will have a significantly better thermal
resistance than any other. This is one of the reasons that aluminum is so popular as a heatsink material - it
can be anodized, and black dye is then introduced into the porous layer of aluminum oxide.
-
8/7/2019 thiet ke inverter
39/56
34
3.4 Wiring Considerations:
One of the most important wiring considerations is that control wire and power wires should never run
parallel to each other. They should be at least 20cm apart and if possible wires should run perpendicular
to each other. For the control connection, shielded wire should be used and the shield should be connected
to earth at both ends of termination. Also since the control signal is 0-5V analog signal, the length of the
wire between the control terminals should not be more than 2m. This places a restriction on the distance
of between the inverter and the Fuel Cell. Furthermore, mounting of the boards inside the inverter cubicle
is of prime importance. It should be mounted firmly to reduce the risk of damage due to vibrations while
operation. The magnetic components and the driver circuit of the inverter should be designed such that it
produces minimum noise.
All the nuts, bolts and screws used should be of brass, which is light in weight and provides conduction
path for ESD to be grounded.
-
8/7/2019 thiet ke inverter
40/56
35
4.0 Educational Impact
4.1 About the university and college
The unparalleled growth and development of University of Central Florida's College of Engineering and
Computer Science is one of those community success stories that can make us all justifiably proud.
Chartered in 1963, the first students arrived in 1968, with initial enrollment numbering 188 in the College
of Engineering. In the Fall of 2000, engineering enrollment was about 4,300, placing UCF in the top 16
percent of all similar colleges in the United States. The charter-engineering faculty numbered eight,
today 150, plus about 30 from other colleges and institutes holding joint appointments in the College. The
College of Engineering and Computer Science has a vision for the future that is made possible through
the dedication of the administrators, faculty, and staff associates within the college who are committed to
the students whom they serve. Three minority and three women students were enrolled in the charter
class, today there are over 600 minority and 700 women. The college is the administrative arm of three
engineering Departments, (Civil and Environmental Engineering, Industrial Engineering and
Management Systems and Mechanical Materials and Aerospace Engineering), a School of Electrical
Engineering and Computer Science, an Engineering Technology Department, and two ROTC units.
There are nine baccalaureate degree programs, 16 masters programs, and eight Ph.D. programs within the
college.
4.2 Power Electronics Progress at UCF
UCF offers graduate and undergraduate level courses in Power Electronics as part of the Electrical
Engineering (EE) degree program.Power Electronics has been as a sub-track in the School of Electrical
Engineering and Computer Science at the University of Central Florida since 1991, when Dr. Batarseh
joined the institution. Two years ago, in order to highlight the importance of educational and research
activities in power electronics at UCF, Florida Power Electronics Center (FloridaPEC) was established.
Website is http://floridapec.engr.ucf.edu FloridaPECs objective is to carry out research and development
activities in the area of power electronics to improve efficiency, power density, performance and most
importantly make the systems practical and cost effective. The main objective for participating in the
-
8/7/2019 thiet ke inverter
41/56
36
Future Energy Challenge 2001 has been to bring an awareness among the budding undergraduate
engineering students about the present day energy situations and possible solutions that the field of power
electronics offers. We believe student participation in this project will allow them to experience first hand
the theoretical and experimental side of the field of power electronics, which provides a very attractive
career opportunity.
4.3 Student Participation in the project
Students having background in power electronics topics were chosen for this project. The team consists of
four undergraduate students and one Masters student. Three of the undergraduates are participating as
members of the capstone senior design project. The project provided the students a wonderful opportunity
to acquire necessary skills and design tools with a practical real life design problem.
The starting point of any project is a good and extensive literature review. The students did an extensive
literature review and that provided the students a good idea about the latest developments in the field of
inverters. Since the inverter was meant for domestic use, the prime goal was that the topology used should
be simple and easy to implement. Also it should be absolutely maintenance free.
The most challenging aspect in the topology chosen was the DC-DC push-pull converter. The presented
push-pull configuration is good for medium to high power applications is around 15kW maybe, beyond
which handling the high input current and keeping the ripples low becomes a tough task. Also making the
inverter compact was another major consideration for choosing the push-pull configuration. At the
proposal writing stage, we did propose to use two parallel half-bridge inverter stages to realize the three-
wire output configuration. That meant that we would have to use extra secondary winding and extra diode
bridge rectifier. However later we did modify the topology without having to put the additional circuitry.
Since this is an unfunded project for FloridaPEC, design optimization was of prime importance for cost
control. All the available resources were put to best possible use. The aim was to build a laboratory level
1.5kW prototype, which meets most of the designed specifications technically and commercially. Based
on the rules of the competition, if the prototype is selected for final testing, then the issues of packaging,
transportation will be taken care of.
-
8/7/2019 thiet ke inverter
42/56
37
Another very important thing from the educational point of view was not a single item has been out
sourced for manufacturing. Every item has been built in the laboratory including the main transformer,
inductors and the PC board.
4.4 Project Design Steps
After the components were designed and results verified mathematically, the following systematic
approach was followed:
Identification of vendors: Each student was given the task of identifying vendors for each of the
components, analyze their products, compare specs with other vendors, contact them for samples and
finally to try and match with the components already existing in our lab. This did provide the students the
opportunity to have conversations with technical experts from industry.
Procurement of components: All the components for this project are procured from Digikey. An online
account was established with Digikey for purchasing components and the students managed the same. At
end of each week, the list of expenditures was submitted to the administrative department for accounting
purposes. Therefore, cost over run was always kept in check.
Designing of magnetic components: A complete systematic design procedure was used for the
magnetics design. Companies like Magnetics and Micrometals did help the university by sourcing sample
cores and bobbins. The students using appropriate wire gauge wound the transformer and inductors. After
the winding, the proper air gap was adjusted and the cores were packed. An Impedance Analyzer was
used to test the values of the magnetic components and the measured values did match the expected
values. For example, the output filter inductor was designed for 2mH. The result from the impedance
analyzer showed Inductance = 1.9mH and the measured resistance was 0.2 ohms.
PCB Layout: The PCB layout was done using Layout Plus software from ORCAD. After finishing the
layout the PC board was etched in the lab by using the T-Tech PCB maker, model Quick circuit 5000.
Special attention was paid to the PCB trace thickness, separation of analog and digital and power signals
for minimizing EMC problems.
-
8/7/2019 thiet ke inverter
43/56
38
DSP software development: For this project the TMS320F240 evaluation module was used. This
evaluation module was already available in our lab and hence the same was used. The development of
software for this DSP requires lot of software development skills and is totally developed by the students.
The total software is still not complete, some parts needs to be modified further to meet all the
specifications and most importantly, the protection mechanism has to be fool proof.
4.5 Educational Benefits
Overall, the project provided a good learning experience for the five students in terms of providing:
Technical multi-disciplinary design opportunity
Opportunity for project planning and management
Knowledge in manufacturing techniques
Use of professional software packages like ORCAD, PowerSIM, PCB maker, etc.
How to manage expenses and reduce cost
Learning means of effective resource utilization
Team work and the importance of project cooperation
Good technical and commercial Communication skills
Realizing the acute power crisis we may face in the future and think of alternatives
Model for senior design projects
-
8/7/2019 thiet ke inverter
44/56
39
5.0 Inverter Operating Instructions
Figure 11 below shows the complete panel schematics
Fig 11: Power panel schematic
Checklist before Powering Up
Observe all of the ESD measures when handling components.
Tightenup all bolts and screws
Correctly, insert all connectors and lock/screw into place
Check the interconnection between the power and the control sections
Observe the poweron sequence as described below
Fuse
vac
BATTERY
48V
_ +
BATTERY
12V
+ -
FUELCELL48V
_ +
Relay R1
MCB1
MCB2
MCB1 AUX
R2 NC
+
_
Push-Pull
Transformer
dc-dc
Inverter Stage
dc-ac
Low-Pass
Filter
Idc Iac
R1 NO
DC Cap
DSP
IL
Vc
Fuel-cell
Ready
Inverter
FaultRelay R2
Vdc
Vin
Iin
PWM
Protection
PWM
OR GATEAnalog
Output
Load
-
8/7/2019 thiet ke inverter
45/56
40
If the unit is frequently powereddown and up, the DC link capacitors retains high voltage even when the
main supply to the inverter is OFF. Only discharge the unit at the DC link buses through a minimum of
10W.
All switches should be in OFF position
Ground all components and connect all of the shields.
Board Designations
A1 : Power Board : Houses the power devices and the power circuitry
A2 : Interface Board : Houses the feedback and the driver circuitry
A3 : DSP Evaluation Board
Power Up and Operation Guidelines
Make the power connections
Turn ON the power supply to the DSP evaluation board
Turn the power supply for the interface board ( from the Battery bank )
Put the Main Power supply MCB ON ( the battery supplies the Inverter )
The auxiliary contact of the MCB turns the battery contactor ON.
The main contactor coil is connected through the NC contact of a control relay, which is
controlled by the analog output of the DSP.
Inverter starts up and the DSP generates a signal Inverter ON . This signal is given to the Fuel
Cell Controller
Inverter keeps running on battery till the fuel cell controller generates the signal Fuel Cell
Ready
Once the Inverter controller receives the ready signal from the Fuel Cell controller, the power
from the battery is cut off through a contactor, after a finite delay. This delay is programmable.
This feature ensures that the inverter actually runs from the fuel cell supply and not supported by
the battery. Battery is used only for back up supply.
-
8/7/2019 thiet ke inverter
46/56
41
During operation, the available power level signal from the fuel cell controller is compared
with the required power level signal of the inverter. Whenever required power level is
greater than available power level, the battery contactor turns ON.
The control relay operates only when the Fuel Cell Ready signal (H = 5V) is received by the
inverter controller.
Under any fault condition, the driving signal from the Inverter controller is inhibited and
Inverter Trip signal is generated. This signal also drops out the battery contactor.
Inverter Status is available through the 9-pin RS232 port and the same port can be used for
troubleshooting the inverter. Necessary software will be supplied.
-
8/7/2019 thiet ke inverter
47/56
42
6.0 Simulation and experimental results
The 1.5kw and 10kw circuit has been simulated using Pspice schematics. The simulation circuits are
shown in Appendix C.
Fig 12: Differential Voltage and current waveform under normal resistive load
Fig 13: Phase 1 and Phase 2 voltage waveform
Differential current for a resistive load of 35
480V pk-pk
-
8/7/2019 thiet ke inverter
48/56
-
8/7/2019 thiet ke inverter
49/56
44
Fig 16: Load current waveform under unbalanced load conditions
Fig 17: Output Filter Capacitor voltage waveform under unbalanced load conditions
Fig18: Output Filter Inductor current waveform under unbalanced load conditions
-
8/7/2019 thiet ke inverter
50/56
45
Fig 19: Voltage feedback waveform for DSP
Fig 20: Current feedback waveform for DSP
Fig 21: Voltage and current waveforms for 10kW system
-
8/7/2019 thiet ke inverter
51/56
46
Experimental Result of 1.5Kw prototype output waveform
-
8/7/2019 thiet ke inverter
52/56
47
7.0 Cost Evaluation Spreadsheet
The modified cost evaluation spreadsheet prepared by the Organizing Committee is attached for both the
1.5kw prototype and 10kw system. A major factor in selection of the components is the rate of
obsolescence. Care has been taken to ensure that all the selected components especially the power devices
and the driver ICs will be supplied by the respective companies for the next 10 years. Hence the
servicing of the product will not be affected even if the components are no longer produced.
In the cost evaluation spreadsheet, exact cost headers considered under the items Losses, Control and
Packaging is not very clearly explained. Hence we have considered $ 50 for the 1.5kw and $100 for the
10kw system under the item Other. This includes costs towards
Protection Fuses, PCB Board
Cables ( Control and Power )
Battery Charger
Surge suppressors
EMI filter
Sensors
Terminal connectors ( ELMAX )
Electricity, Telecommunication and stationary
The design of feedback circuitry and the DSP control scheme including software does not change with the
increase of power rating and hence the increase in cost towards these items is not proportional to power
rating. The costing principle followed should be Activity based costing as that is most logical for mass
production in a factory. The complete process of from the design table to the completed product is broken
up into activities and each activity is assigned a cost. The prototype is developed totally inside the school
lab and hence the spreadsheet calculation may not reflect the exact costing especially the magnetic
components.
-
8/7/2019 thiet ke inverter
53/56
2001 FUTURE ENERGY CHALLENGE : 1.5kW COSTING
UNIVERSITY: University of Central Florida
NAME OF MAIN CONTACT: Dr Issa Batarseh
PROJECT NAME: EnergyChallenge 2001
DATE: 15th June, 2001
VOLT VOLT CUR CUR UNIT XTENDED
DEVICE QTY DESIG UNIT EASURE (Vpk) (Vrms) (Avg) (Arms) COST COST
DIODE 4 D1-D4 500 10 2.51 10.05
IGBT 4 Q3-Q6 600 20 4.86 19.44
MOSFET 4 Q1-Q2(2 Parallel) 200 45 8.65 34.58
CAP (ALUM) 2 C1,C2 560 uF 450 15.80 31.61
CAP (ALUM) 3 CIN 0.22 uF 100 0.10 0.31
CAP (FILM) 2 C3,C4 10 uF 400 7.98 15.96
POWER RESISTOR 4 R1-R4 50 W 2.64 10.56
CHOKE 3 L1,L2.L3 2000 UH 8 47.76 143.29
TRANSFORMER 1 T1 48 55 9.17 9.17
CONTACTORS 2 M1,M2 48 55 4.74 9.48
CONTACTORS 1 Relay 1 5 1 2.83 2.83
LOSSES 200 W 16.67 16.67CONTROL 60.79
PACKAGING 45.59
OTHER (EXPLAIN) 50.00
TOTAL 460.33
-
8/7/2019 thiet ke inverter
54/56
2001 FUTURE ENERGY CHALLENGE : 10kW COSTING
UNIVERSITY: University of Central Florida
NAME OF MAIN CONTACT: Dr Issa Batarseh
PROJECT NAME: EnergyChallenge 2001
DATE: 15th June, 2001
VOLT VOLT CUR CUR UNIT XTENDED
DEVICE QTY DESIG UNIT EASURE (Vpk) (Vrms) (Avg) (Arms) COST COST
DIODE 4 D1-D4 500 45 4.10 16.39
IGBT 4 Q3-Q6 600 50 11.98 47.91
MOSFET 6 Q1-Q2(2 Parallel) 200 100 14.57 87.42
CAP (ALUM) 2 C1,C2 2200 uF 400 48.84 97.68
CAP (ALUM) 3 CIN 0.22 uF 100 0.10 0.31
CAP (FILM) 2 C3,C4 120 uF 250 35.07 70.15
POWER RESISTOR 4 R1-R4 100 W 4.24 16.96
CHOKE 3 L1,L2.L3 180 UH 45 61.19 183.56
TRANSFORMER 1 T1 48 225 18.16 18.16
CONTACTORS 2 M1,M2 48 225 10.65 21.29
CONTACTORS 1 Relay 1 5 1 2.83 2.83
LOSSES 1000 W 83.33 83.33
CONTROL 129.20
PACKAGING 96.90
OTHER (EXPLAIN) 100.00
TOTAL 972.09
-
8/7/2019 thiet ke inverter
55/56
References Cited
[1] Energy Challenge website http://www.energychallenge.org
[2] Ying-Yu Tzou; Shih-Liang Jung, Full control of a PWM DC-AC converter for AC voltage regulation,
Aerospace and Electronic Systems, IEEE Transactions on, Volume: 34 Issue: 4, Oct. 1998 Page(s): 1218 1226
[3] Shireen, W.; Arefeen, M.S., An utility interactive power electronics interface for alternate/renewable energy
systems, Energy Conversion, IEEE Transactions on, Volume: 11 Issue: 3, Sept. 1996 Page(s): 643 649
[4] Chiang, S.J.; Liaw, C.M., Single-phase three-wire transformerless inverter, Electric Power Applications,
IEEE Proceedings-, Volume: 141 Issue: 4, July 1994 Page(s): 197-205
[5] Venkataramanan, G.; Divan, D.M., Pulse width modulation with resonant DC link converters, Industry
Applications, IEEE Transactions on, Volume: 29 Issue: 1 Part: 1, Jan.-Feb. 1993 Page(s): 113 -120
[6] Gui-Jia Su; Ohno, T., A new topology for single phase UPS systems, Power Conversion Conference
Nagaoka 1997, Proceedings of the, Volume: 2, 1997 Page(s): 913 -918 vol.2
[7] Mohan, N., Undeland, T., Robbin, W., (1995). Power Electronics: Converters, Applications, and Design. New
York. John Wiley & Sons, Inc.
[8] Rashid M. H., Power Electronics: Circuit Devices, and Applications. New Jersey.Prentice Hall 1993.
[9] Enrique A. Tenicela, A Study of Pulse Width Modulation Techniques in Power Static Inverters , a thesis
submitted in partial fulfillment of the requirements for the Honors Program at UCF, Orlando, Florida.
[10] Texas Instrument website http://www.ti.com
[11] Pekik Dahono, A Purwadi and Qamaruzzaman, A LC Filter design for single phase PWM inverters
[12] US Department of energy website http://www.energy.gov
[13] Powerdesigners Inc website http://www.powerdesigners.com
[14] Dr Issa Batarseh, Introduction to Power Electronics, chapter 4,5 and 9.
[ 15] Colonel Wm T Mclyman , "Magnetic Core Selection for Transformers and Inductors"
-
8/7/2019 thiet ke inverter
56/56
You have reached the end
of this final report.
Use the button below toreturn to the Main Document
Return to Main Document