Nortel TN-1X Installation Procedures
SDH TRANSMISSION
Nortel TN-1X
Installation Procedures
Document Number: 323-1061-200Document Status: StandardProduct Release Number: Release 7Date: October 1997
Copyright
ã
1995, 1996, 1997 Northern Telecom
Printed in England
The copyright of this document is the property of Northern Telecom. Without the written consent of Northern Telecom, given by contract or otherwise, this document must not be copied, reprinted or reproduced in any material form, either wholly or in part, and the contents of this document, or any methods or techniques available therefrom, must not be disclosed to any other person whatsoever.
NORTHERN TELECOM CONFIDENTIAL:
The information contained in this document is the property of Northern Telecom. Except as specifically authorized in writing by Northern Telecom, the holder of this document shall keep the information contained herein confidential and shall protect same in whole or in part from disclosure and dissemination to third parties and use same for evaluation, operation and maintenance purposes only.
So far as Northern Telecom is aware the contents of this document are correct. However, such contents have been obtained from a variety of sources and Northern Telecom can give no warranty or undertaking and make no representation as to their accuracy. In particular, Northern Telecom hereby expressly excludes liability for any form of consequential, indirect or special loss, and for loss of data, loss of profits or loss of business opportunity, howsoever arising and whether sustained by the user of the information herein or any third party arising out of the contents of this document.
v
Publication history
Nortel TN-1X Installation Procedures
October 1997Release 7 Standard.
December 1996Release 6 Standard.
December 1995Release 5.1 Standard.
vii
Contents
Nortel TN-1X Installation Procedures
About this document xiTechnical support and information xiiiWarnings and cautions xvii
Receiving and unpacking 1-1Off-loading 1-1Package handling 1-1Storage 1-1Unpacking 1-2
Tools required 1-2Packaging removal 1-2Packaging disposal 1-2
Checking contents 1-2
Installation information 2-1Installation tools 2-1Equipment supplies 2-2Installation items 2-4Installation procedure 2-6
Overview 2-6Installation of trafÞc cables to rack 2-8Cable and Þbre labelling 2-11Installation of subrack into the rack 2-13Insertion and removal of plug-in units and interface modules 2-16Connections - Station Service Module 2-20Connections - 75 W Star Card Module 2-24Connections - Flexible Access Module 2-26Connections - 75 W TrafÞc Access Module 2-28Connections - 120 W TrafÞc Access Module 2-30Connections - High Speed TrafÞc Access Module 2-32Connections - High Speed Aggregate Module 2-34Connections - High Speed Tributary Module 2-36Connections - optical aggregate/tributary units 2-38
Single Þbre working mode 2-41Local Craft Access Panel 2-42EOW telephone 2-43Fitting inÞlls, covers and designation labels 2-44
Appendix A: Installation kits parts list 3-1
Index 4-1
viii
Figures
323-1061-200 Release 7 Standard
Figure 1-1 Unpacking the subrack 1-3Figure 1-2 Typical TN-1X subrack layout 1-4Figure 2-1 Overview flowchart (part 1) 2-6Figure 2-2 Overview flowchart (part 2) 2-7Figure 2-3 Cable support 2-10Figure 2-4 Tributary cable dressing 2-11Figure 2-5 Cable marker and positioning 2-12Figure 2-6 Captive nut and shoulder washer positions 2-14Figure 2-7 Subrack brackets and fibre turning devices (ETSI rack only) 2-15Figure 2-8 Plug-in unit insertion/removal 2-18Figure 2-9 Interface module insertion/removal 2-19Figure 2-10 Station Service Module layout 2-21Figure 2-11 Rack alarm bus connection termination 2-22Figure 2-12 Power connector termination 2-23Figure 2-13 75 W Star Card Module layout 2-25Figure 2-14 Flexible Access Module - front and side views 2-27Figure 2-15 75 W Traffic Access Module layout and port allocations 2-29Figure 2-16 120 W Traffic Access Module layout and port allocation 2-31Figure 2-17 High Speed Traffic Access Module layout 2-33Figure 2-18 High Speed Aggregate Module layout 2-35Figure 2-19 High Speed Tributary Module layout 2-37Figure 2-20 Typical layout of optical units 2-38Figure 2-21 Optical fibre routing 2-40Figure 2-22 Single fibre working couplers 2-41Figure 2-23 LCAP layout 2-42Figure 2-24 EOW handset stowage 2-43Figure 2-25 Station Interface Area cover assembly 2-45Figure 2-26 Fibre tray cover, subrack label and infill panels 2-46Figure 2-27 Fitting dummy covers 2-46
TablesTable 2-1 Special tools 2-1Table 2-2 Core items 2-2Table 2-3 Plug-in units 2-2Table 2-4 Service Interface Modules (SIM) 2-3Table 2-5 Traffic Interface Modules (TIM) 2-3Table 2-6 Items required for installing the subrack 2-4Table 2-7 75 W traffic cord options 2-5Table 2-8 Cable routing for 2 Mbit/s tributary units 2-8Table 2-9 Cable routing for 34 Mbit/s tributary units 2-9Table 2-10 Power connector pin-out details 2-24Table 2-11 Pin-out for 120 W traffic cords 2-30Table 3-1 Installation kit for NT ETSI rack (25S KM00 019 AAE) 3-1Table 3-2 Installation kit for 23" rack (for example, OPAC cabinet) 3-1Table 3-3 Installation kit for 19" rack (25S KM00 750 HNZ) 3-2Table 3-4 Installation kit for Rack 91 (25S KM00 750 HPB) 3-2Table 3-5 Installation kit for Rack 90 (25S KM00 750 HPC) 3-2Table 3-6 Subrack cover kit (25S KM00 750 HFL) 3-3Table 3-7 NT ETSI rack dummy cover kits 3-3Table 3-8 TN-1X installation kit (25S KM00 807 ABL) 3-4Table 3-9 EOW handset kit (25S KM00 750 HZM) 3-4
ix
Procedures
Nortel TN-1X Installation Procedures
Procedure 2-1 Installing traffic cables to rack 2-8Procedure 2-2 Cable and fibre labelling 2-11Procedure 2-3 Installing the subrack in the rack 2-13Procedure 2-4 Insertion and removal of plug-in units and interface modules 2-17Procedure 2-5 LAN connections 2-20Procedure 2-6 Rack alarm bus connections 2-22Procedure 2-7 Power connections 2-23Procedure 2-8 Connecting the SIM Type 20 2-24Procedure 2-9 External alarm connections 2-26Procedure 2-10 Connections to 75 W Traffic Access Module 2-28Procedure 2-11 Connections to 120 W Traffic Access Module 2-30Procedure 2-12 Connections to High Speed Traffic Access Module 2-32Procedure 2-13 Connections to High Speed Aggregate Module 2-34Procedure 2-14 Connections to High Speed Tributary Module 2-36Procedure 2-15 Connections to optical units 2-39Procedure 2-16 EOW telephone mounting 2-43Procedure 2-17 Fitting the infills, covers and designation label 2-44
xi
About this document
Nortel TN-1X Installation Procedures
This document, 323-1061-200, provides details of the mechanical installation procedures for the Nortel TN-1X Release 7 subrack into the following rack types:
¥ NT ETSI.
¥ 19" rack/cabinet.
¥ 23" rack/cabinet (OPAC).
¥ BT Rack Types 90/91.
General view of a typically equipped TN-1X subrack
xii
About this document
It is assumed that the rack is securely in place and that all cabling and services
323-1061-200 Release 7 Standard
to the rack have been completed in readiness for installation of the subrack.
Associated documentsNortel TN-1X Documentation Overview and Safety, NTP 323-1061-090.
Nortel TN-1X System Commissioning Procedures, NTP 323-1061-220.
xiii
Technical support and information
Nortel TN-1X Installation Procedures
Nortel provides a comprehensive technical support service for its customers. The Nortel Service Desk may be contacted Monday to Friday between the hours of 08:30 and 17:00 (UK local time), using the following FAX or telephone numbers:
United KingdomFreephone: 0800 626 881Telephone: 0181 361 4693FAX: 0181 945 3456
InternationalTelephone: +44 181 361 4693FAX: +44 181 945 3456
Access to assistance from the Customer Service Desk 24 hour help line can be provided and is subject to a suitable Support Agreement being in place.
To discuss Technical Support services, please contact the Technical Support Hotline on 0181 945 3525.
Declaration of product safety and EMC compliance
This product/product family complies with the provisions of the Low Voltage Directive 73/23/EEC, and with the essential protection requirements of the EMC Directive 89/336/EEC as amended by 92/31/EEC, when it is properly installed and maintained and when it is used for the purposes for which it is intended.
xvii
Warnings and cautions
Nortel TN-1X Installation Procedures
Safety considerationsEnsure that you are familiar with the general safety procedures relating to the TN-1X product detailed in ÔDocumentation Overview and Safety, NTP 323-1061-090Õ.
Follow all warning notices provided with this product, as well as the safety procedures established by your company.
Follow all caution notices provided with this product, as well as the general equipment safety procedures established by your company.
Mechanical handling considerations
WARNINGRisk of personal injuryDue to the weight of the subrack, the mounting of the subrack in the rack requires two installers for safe working.
Take care when working near the top of the Station Interface Area that your hands do not scrape on the honeycomb screen.
CAUTIONRisk of damage to EMC meshThe EMC mesh on the subrack must not be placed onto an uneven surface or be placed on any protruding objects.
CAUTIONRisk of damage to equipmentWhen inserting a plug-in unit, ensure that the plug-in unit is inserted in the black card-guides and not the grey front panel locator guide to the right of the required position.
xviii
Warnings and cautions
Electrical handling considerations
323-1061-200 Release 7 Standard
Electrical safety considerations
Optical safety
Note: The subrack should not be powered until after the installation is completed.
CAUTIONStatic sensitive devicesThe plug-in units contain static sensitive devices. These devices are sensitive to static electricity and must be protected by special handling and packaging. Refer to the static sensitive handling procedures in ÔDocumentation Overview and Safety, NTP 323-1061-090Õ.
Before removing the TN-1X subrack from the inner carton of the packaging, personnel must wear conductive bonded wrist straps conforming to BS CECC 00015 Part 1. The straps must be connected to an available earth point in the absence of an ESD bonding point on the equipment.
WARNINGPower to the subrackThe subrack should not be powered-up until the installation procedures are completed and the subrack is ready for commissioning. If the parent rack is already powered, the relevant rack fuses must be removed before the power connector is connected to the subrack.
CAUTIONOptical safetyObserve the warnings and cautions detailed in ÔDocumentation Overview and Safety, NTP 323-1061-090Õ.
Warnings and cautions
xix
Optical connector/Þbre handling
Nortel TN-1X Installation Procedures
The following precautions must be taken when working with single-Þbre optical cables:
¥ Safety glasses must be worn when installing optical Þbres.
¥ Small bits of glass Þbre are almost invisible. After handling single Þbre cables, hands should always be wiped clean or washed before making any contact with the eyes.
Handle optical Þbres carefully and always position them in a safe and secure location during installation.
¥ Do not handle pieces of cut Þbre with bare Þngers. Use tweezers, or the sticky side of a piece of vinyl tape, to pick up and discard any loose Þbre ends.
¥ All Þbre cuttings should be placed in a plastic bottle provided for that purpose.
end of chapter
CAUTIONOptical connectorsClean all optical connectors by an approved method before making any optical connection.
When making an optical connection, do not rotate the optical connector unnecessarily.
When not connected, Þt all optical plugs and couplings with captive caps.
CAUTIONDamage to optical ÞbresWhen dressing Þbres, take care not to exceed the minimum bend radius (typically 35 mm) and do not overtighten tyraps used for dressing as damage may result.
When connecting connectors, ensure that the optical Þbres are not trapped by the protective cover on the unit before sliding the unit in position.
WARNINGDanger from glass chipsIf there is any suspicion of a glass chip in the eye, seek medical attention at once.
1-1
1
Receiving and unpacking 1-
Nortel TN-1X Installation Procedures
This chapter describes the procedures to be used when a Nortel TN-1X subrack is delivered to the customer as part of a supply-only contract.
Off-loadingThe consignment is the responsibility of the delivery vehicle driver until it has been off-loaded to the installation or storage area. Off-loading must therefore be supervised by the driver.
Only authorised lifting equipment and slings must be used unless a reciprocal agreement for use of the customerÕs equipment is in force and is valid.
Package handlingIdentify the top face of the container, identiÞable by packing labels, and keep the top face uppermost at all times.
The package contents are to be considered fragile at all times.
If packages are to be handled in wet weather conditions, adequate waterproof covering must be used to protect the package.
StorageIf the TN-1X equipment is to be stored before installation, the following storage conditions must be applied:
¥ Do not remove the equipment from its protective packaging.
¥ Store the equipment in an environment which is dry and controlled to prevent the formation of condensation.
¥ Whenever possible, store packages at a height which eases handling, i.e. between waist and shoulder height.
¥ Do not store the packages near sources of heat.
¥ Do not place heavy objects, e.g. wooden transit cases, on top of the package.
1-2
Receiving and unpacking
Unpacking
323-1061-200 Release 7 Standard
Tools requiredThe following tools are required to remove a TN-1X subrack from its primary and secondary packaging:
¥ Sharp pointed blade knife
¥ Conductive bonded wrist strap conforming to BS CECC 00015 Part 1
Packaging removalThe removal procedure is detailed in Figure 1-1.
Packaging disposalThe packaging may be disposed of as waste material. The customer may, however, Þnd it advantageous to retain the packaging which may then be used to return the equipment to Nortel should the need arise.
Checking contentsCheck the package contents against the Customer's Advice Note and ensure that the range of plug-in units Þtted to the supplied matches the TN-1X variant speciÞed on the order.
Figure 1-2 shows the layout of the plug-in units and interface modules of a typical equipped subrack.
Receiving and unpacking
1-3
1
Figure 1-1
Nortel TN-1X Installation Procedures
Unpacking the subrack
STEP 1Cut through gummed paper.DO NOT insert knife more than 5mmOpen the outer carton to exposethe inner carton
STEP 2Remove the fourtop corner blocks
STEP 3Cut through gummed paperof inner carton in a similarmanner to Step 1
STEP 4Open inner carton and liftout the 5 panel wrappercontaining the subrack
TopCornerBlocks(4 off)
Inner Carton
5 Panelwrapper
Subrack
1-4 Receiving and unpacking
323-10
Fig
ure 1-2
Typical T
N-1X
sub
rack layou
t
end of chapter
utary Unit
load Manager
ical or Electrical Aggregate Unit
ical or Electrical Aggregate Unit
er Unit
rack Controller
2634
6271
Unit
tection Trib Unit/Dummy Panel
16
1116
2142
4752
5780
Associated card
guide position
Plug-in unit slot
position
Assoc
guide
Syste
modu
S1
S2
S3
S4
S5
S6
S7
S8
S9
S10
S11
S12
S13
S14
utary Unit
load Manager
utary Unit
my Panel
utary Unit
er Unit
Plug-in U
nit (PIU
) A
rea
Serv
Area
61-200 Release 7 S
tandard
Trib
Pay
Opt
Opt
Pow
Sub
75 W Star Card
Station Service Module
Flexible Access Module
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
T13
T14
T15
T16
110
1520
2530
3540
4550
5560
6570
7580
EOW
Pro
iated card position
m interface
le slot position
High Speed Aggregate ModuleDummy Panel
1"1"
1"
Trib
1"1"
1.6"1.6"
Pay
1"1" Trib
1" Dum
Trib
1"1.8"
Pow
1.8"1"
1.8"
Traffic Access Module
Traffic Access Module or High Speed Trib Module
Dummy Panel
1"1"
1"1"
1"1"
1"1"
1"1"
1"1"
1"1"
Dummy Panel
Dummy Panel
High Speed Aggregate ModuleDummy Panel
1"
Traffic Access Module
Traffic Access Module
Traffic Access Module or High Speed Trib Module
Traffic Access Module
ice Interface (S
IA)
Traffic Access Module or High Speed Trib Module
Traffic Access Module or High Speed Trib Module
2-12
Installation information 2-
Nortel TN-1X Installation Procedures
Table 2-1 lists the special tools required to carry out the installation of the TN-1X subrack.
Table 2-2 to Table 2-5 list the range of the plug-in units and interface units available for Release 6 of the TN-1X. The units supplied will depend upon the customer speciÞc order.
Table 2-6 lists the installation kits and materials required. Table 2-7 lists the different 75 W trafÞc cord options.
Installation toolsTable 2-1Special tools
Item Code Description Qty
1 25T XT00 800 POO 43T connector insertion/extraction tool (long) 1
2 25S KM00 800 EFO Microscope kit 1
3 25S KM00 800 FMO Optical fibre cleaning kit 1
4 25T PL00 800 BOO ERMA crimp tool 1
5 25T PL00 800 COO Die set (for 3002 cable) As required
6 25T PL00 800 DOO Die set (for 2002 cable) As required
7 25T PL00 800 EOO Die set(for 2003 cable and d.c. power pins type 2A)
1
8 25T XT00 800 AOO Pin extractor tool (for d.c. power pins type 2A) 1
9 25T CS00 800 XOO Coax cable stripping tool 8A (2002/2003) As required
10 25T CS00 800 ADO Coax cable stripping tool 9A (3002) As required
11 25T PL00 800 HOO Parallel jaw pliers 1
12 25T XT00 001 AAF TN-1X special extractor tool 1 (see Note)
Note:This tool is only required if dust covers on the backplane connectors need to be removed when adding new units to an existing subrack (i.e. access to the dust covers is restricted by existing units).
2-2 Installation information
Equipment supplies
323-1061-200 Release 7 Standard
Table 2-2Core items
Item Code Description
1 25G MU00 750 GWV Unequipped subrack TN-1X
2 25U EP00 750 GXB Local Craft Access Panel 75 W
Table 2-3Plug-in units
Item Code Description
1 25U PW00 750 HAY/HSY Power Supply Unit (PSU)
2 25U MN00 750 GXD Subrack Controller
3 25U PJ00 750 GXF Payload Manager
4 25U PJ00 750 HZQ Payload Manager TSI-2
5 NTKD10AA Payload Manager, Mixed Payload
6 25U TM00 750 HWF STM-1 Optical Aggregate Unit LH/SH
7 25U TM00 750 GWA STM-1 Optical Aggregate Unit
8 25U TM00 750 GWB STM-1 Electrical Aggregate Unit
9 25U TM00 750 HVB STM-4 Optical Aggregate Unit 1550 nm
10 25U TM00 750 GSA STM-4 Optical Aggregate Unit (Long Haul), 1310 nm
11 25U TM00 750 GSC STM-4 Optical Aggregate Unit (Intra-Station), 1310 nm
12 25U JU00 750 GXG 2 Mbit/s Tributary Unit 75 W
13 25U JU00 750 GXR 2 Mbit/s Tributary Unit 120 W
14 25U JU00 750 HVT 2 Mbit/s Tributary Unit 75 W
15 25U JU00 750 HVQ 2 Mbit/s Tributary Unit 120 W
16 25U JU00 750 GVA STM-1 Optical Tributary Unit 2"
17 25U TM00 750 HWE STM-1 Optical Tributary Unit 1"
18 25U TM00 750 HWG STM-1 Optical Tributary Unit 1" TSI-2
19 NTKD11AA STM-1 Optical Tributary Unit 1" Mixed Payload
20 25U JU00 750 GVB STM-1 Electrical Tributary Unit 2"
21 25U JU00 750 JBK STM-1 Electrical Tributary Unit 2" TSI-2
22 NTKD12AA STM-1 Electrical Tributary Unit 1" Mixed Payload
23 25U JU00 750 HJZ 34 Mbit/s Tributary Unit
ÑcontinuedÑ
Installation information 2-3
2
Table 2-3
Nortel TN-1X Installation Procedures
24 25U SV00 750 GVX EOW Unit (ICC1)
25 NTKD13AA EOW Unit (ICC2)
26 25S KM00 750 HZM EOW Installation Kit (see Appendix A, Table 3-9 for details)
27 25U MU00 750 HVJ Asynchronous Telemetry UnitNote: Installation of the ATU is described in NTP 323-1063-200.
ÑendÑ
Table 2-4Service Interface Modules (SIM)
Item Code Description
1 25U JJ00 750 GXC Station Service Module
2 25U JJ00 750 GWZ 75 W Star Card (Clock Sync)
3 25U JJ00 750 GWX Flexible Access Module
4 25U JJ00 750 HPD Flexible Access Module
Table 2-5Traffic Interface Modules (TIM)
Item Code Description
1 25U JJ00 750 GVZ 75 W Traffic Access Module
2 25U JJ00 750 HLV 120 W Traffic Access Module
3 NTKD14AA 75 W Traffic Access Module (N+1 Protection)
4 NTKD15AA 120 W Traffic Access Module (N+1 Protection)
5 25U JJ00 750 GYZ High Speed Aggregate Module
6 25U JJ00 750 GWY High Speed Tributary Module
7 25U JJ00 750 HTD High Speed Traffic Access Module
Plug-in units (continued)
Item Code Description
2-4 Installation information
Installation items
323-1061-200 Release 7 Standard
Table 2-6Items required for installing the subrack
Item Code Description Qty Notes
1
1b
1c
1d
1e
25S KM00 019 AAE
### #### ### ###
25S KM00 750 HNZ
25S KM00 750 HPB
25S KM00 750 HPC
TN-1X Installation Kit(NT ETSI rack)
TN-1X Installation kit(23Ó rack/cabinet)
TN-1X mounting kit(19" rack/cabinet)
TN-1X mounting kit(Rack 91)
TN-1X mounting kit(Rack 90)
1
See Appendix A Table 3-1 for contents
See Appendix A Table 3-2 for contents (see Note)
See Appendix A Table 3-3 for contents
See Appendix A Table 3-4 for contents
See Appendix A Table 3-5 for contents
2 25S KM00 807 ABL TN-1X Installation Kit 1 See Appendix A Table 3-8 for contents
3 25S KM00 750 HFL Subrack cover kit 1 See Appendix A Table 3-6 for contents
4 32Y CN00 100 AWY TX/RX cable assembly labelled
1 Connection to LAN transceiver for network management system
5 25Y CN00 801 *** Optical fibre tail 2 per module
Connection to FC/PC connectors on optical aggregate and tributary units
6 32Y CN00 754 ***
orP0874818 (5 m)P0874819 (10 m)P0874820 (15 m)P0874821 (20 m)P0874822 (25 m)P0874823 (30 m)
25-way D-type male/4 quad screened cable assembly
25 Way Male D type cord assembly (50û shell) - solid conductor (for wire wrap installations)
1 per module
Connection to ÔOUTPUTÕ connector of 120 W Traffic Access Module
7 32Y CN00 755 ***
orP0874812 (5 m)P0874813 (10 m)P0874814 (15 m)P0874815 (20 m)P0874816 (25 m)P0874817 (30 m)
25-way D-type female/4 quad screened cable assembly
25 Way Female D type cord assembly (50û shell) - solid conductor (for wire wrap installations)
1 per module
Connection to ÔINPUTÕ connector of 120 W Traffic Access Module
ÑcontinuedÑ
Installation information 2-5
2
Table 2-6
Nortel TN-1X Installation Procedures
Note: The last three characters of the cable/cord assemblies signify the length and, in the case of optical cords, the connector types used. All cords are connectorised at one end only.
Ensure that all the necessary items are available and that the parent rack is securely mounted in position. Ancillary items (i.e. Rack Alarm Unit, DC distribution, LAN tray) must be in place prior to the installation of the subrack.
Installation may now proceed in accordance with the following section.
8 32C CN16 100 AJH Connector female 25-way D-type
1 For External Alarms connector
9 NTKD0100 2-1 Optical Converter Box (coupler)
A/R Only required for single fibre working (see page 2-41)
Note: Contact Nortel for advice on space required above and below rack and if fans are required due to ambient temperature.
Table 2-775 W trafÞc cord options
Item Code/Description
1 Preferred option, using 8-core 3002 cable type R011688532Y CN00 725 *** BT43/5F, 8 x 3002 cable
2 Alternative option, using single 3002 coax32Y CN00 750 *** BT43/5F, 3002 cable
3 Alternative option, using single 2003 coax32Y CN00 752 *** BT43/3F, 2003 cable
4 Alternative option, using single 2002 cable32Y CN00 756 *** BT43/5F, 2002 cable
Items required for installing the subrack (continued)
Item Code Description Qty Notes
2-6 Installation information
Installation procedure
323-1061-200 Release 7 Standard
A general view of a typically equipped TN-1X subrack is given on page viii.
OverviewThe ßowchart in Figure 2-1 and Figure 2-2 describes the actions to be carried out and the sequence to be followed in completing the installation of the TN-1X subrack. The ßowchart directs the installer to the relevant procedure for each action.
Figure 2-1Overview ßowchart (part 1)
WARNINGRisk of personal injuryDue to the weight of the subrack, the mounting of the subrack in the rack requires two installers for safe working.
Power to the subrackThe subrack should not be powered-up until the installation procedures are completed and the subrack is ready for commissioning. If the parent rack is already powered, the relevant rack fuses must be removed before the power connector is connected to the subrack.
Install trafÞc cables
Procedure 2-1
Insertion/removal of PIUs and interfaces
modules
Procedure 2-4
Start
Are plug-in units & interface modules Þtted
to the subrack ?
Install subrack into rack
Procedure 2-3
Continued onFigure 2-2
NO
YES
Cable and Þbre labelling
Procedure 2-2
Installation information 2-7
2
Figure 2-2
Nortel TN-1X Installation Procedures
Overview ßowchart (part 2)
YESOptical connections
Procedure 2-15
LCAP connections(no installation required, see ÒLocal Craft Access PanelÓ on page 2-42Õ)
Are optical units
Þtted?
This completesthe subrack installation
procedures
EOW Telephone
Procedure 2-16
Fitting inÞlls, covers and designation labels
Procedure 2-17
NO
Continued from Figure 2-1
Interface Module Connections
Module type Procedure
Station Service Module Procedure 2-5Procedure 2-6
Procedure 2-775 W Star Card Module Procedure 2-8Flexible Access Module Procedure 2-975 W TrafÞc Access Module Procedure 2-10120 W TrafÞc Access Module Procedure 2-11High Speed TrafÞc Access Module Procedure 2-12High Speed Aggregate Module Procedure 2-13High Speed Tributary Module Procedure 2-14
2-8 Installation information
Installation of trafÞc cables to rack
323-1061-200 Release 7 Standard
Procedure 2-1 details the procedure for installing trafÞc cables into an NT ETSI rack, a 19" rack, or a BT Type 90 or 91 rack. The choice of cables will depend on customer requirements.
Procedure 2-1Installing trafÞc cables to rack
Step Action Reference
ÑendÑ
1 Determine the routing of the traffic cables depending on the number of 2 Mbit/s and 34 Mbit/s tributary cables required and the cable entry (top or bottom) to the rack.
Table 2-8Table 2-9
2 For top cable entry, run the cables into the rack and leave at least 850 mm below the designated top fixing position of the subrack. This allows sufficient cable for dressing and termination.
3 For bottom cable entry, run the cable up the rack and leave at least 250 mm above the designated top fixing position of the subrack.
4 To assist in laying the cable in, Figure 2-4 illustrates the dressing layout after the cords have been terminated.
Figure 2-4
5 Secure all cables using tyraps.
Table 2-8Cable routing for 2 Mbit/s tributary units
Number/position of 2 Mbit/s Tributary Units
Routing for 75 W cables Routing for 120 W cables(25-way D-type cords)
One, position 06 32 cords to be run in the left hand duct.
4 cords to be run in the left hand duct.
Two, positions 06 and 57 32 cords to be run in the left hand duct, 30 cords to be run in the right hand duct.
4 cords to be run in the left hand duct, 4 cords to be run in the right hand duct.
Three, positions 06, 16, and 57
64 cords to be run in the left hand duct, 30 cords to be run in the right hand duct.
8 cords to be run in the left hand duct, 4 cords to be run in the right hand duct.
Four, positions 06, 16, 47, and 57
64 cords to be run in the left hand duct, 62 cords to be run in the right hand duct.
8 cords to be run in the left hand duct, cords to be run in the right hand duct.
Installation information 2-9
2
Table 2-9
Nortel TN-1X Installation Procedures
Cable routing for 34 Mbit/s tributary units
Number/position of 34 Mbit/s Tributary Units
Routing for cables
One, position 06 2 cords to be run in the left hand duct.
Two, positions 06 and 57 2 cords to be run in the left hand duct, 2 cords to be run in the right hand duct.
Three, positions 06, 16, and 57 4 cords to be run in the left hand duct, 2 cords to be run in the right hand duct.
Four, positions 06, 16, 47, and 57 4 cords to be run in the left hand duct, 4 cords to be run in the right hand duct.
2-10 Installation information
Figure 2-3
323-1061-200 Release 7 Standard
Cable support
Cables entry/exit
Installation information 2-11
2
Figure 2-4
Nortel TN-1X Installation Procedures
Tributary cable dressing
Cable and Þbre labellingAll cables and Þbres are to be labelled at the rack with designations agreed with the customer. The labelling kit is supplied as part of the TN-1X installation kit (Appendix A, Table 3-8 Item 1).
Procedure 2-2Cable and Þbre labelling
Step Action Reference
ÑendÑ
1 Prepare all markers by neatly writing the designation on the white area using a ball-point pen or permanent marker.
Figure 2-5
2 Peel off the marker from the backing card.
3 Fix each marker in turn to the relevant cable by placing the white area (with the designation side showing) on the cable and wrapping the transparent part round it.
Figure 2-5
4 Ensure that each marker is positioned so that the legend can be read without the need to move or twist any cables.
5 Ensure that, where possible, markers are neatly and uniformly positioned on the cables.
6 Make a final check to ensure that all designations are consistent with project documentation (cable schedules, site drawings).
SHELFPOSITION
21
25U
JU
00750**
* 25U
JU
00750**
* 25U
JU
00750**
* 25U
JU
00750**
*25U
PJ00750**
* 25U
PJ00750**
* 25U
MN
00750**
*25U
PW
00750**
*25U
TM
00750**
* 25U
TM
00750**
* 25U
PW
00750**
*
RECEIVE ATTALARM ALM ACK
ESD
Vertical airflow requirement
SHELFPOSITION
21
RECEIVE ATT
ALARM
ALM ACKESD
25U
JU
00750**
* 25U
JU
00750**
* 25U
JU
00750**
* 25U
JU
00750**
*25U
PJ00750**
* 25U
PJ00750**
* 25U
MN
00750**
*25U
PW
00750**
*25U
TM
00750**
* 25U
TM
00750**
* 25U
PW
00750**
*
Vertical airflow requirement
75 W Tributary coax cords 120 W Tributary cords, 25-way D-type
2-12 Installation information
Figure 2-5
323-1061-200 Release 7 Standard
Cable marker and positioning
Transparent ÔMylarÕ area
White vinyl designation area X
XX
-XX
X
CustomerÕsdesignation(as required)
XX-X
Clear Area
Wrap
Installation information 2-13
2
Installation of subrack into the rack
Nortel TN-1X Installation Procedures
Procedure 2-3 details the mounting of the TN-1X subrack into an NT ETSI rack, a 19" rack, or a BT 90/91 rack. The installation involves Þtting the subrack mounting brackets to the subrack and Þtting captive nuts to the parent rack. In the case of the ETSI rack, Þbre turning devices are also Þtted to the subrack and slide mounts may be used as a subrack mounting aid. For the BT racks, Þbre turning devices are Þtted, but slide mounts are not used.
The item numbers in Procedure 2-3 refer to Table 3-1 to Table 3-5 in Appendix A.
Procedure 2-3Installing the subrack in the rack
Step Action Reference
ÑendÑ
WARNINGRisk of personal injuryDue to the weight of the subrack, the mounting of the subrack in the rack requires two installers for safe working.
1 Locate the top and bottom fixing holes on each side of the rack and fit captive nuts (Table 3-1 Item 1, Table 3-3 Item 3).
Figure 2-6
2 For ETSI and BT racks, fit the fibre turning devices (Table 3-1 Item 6) to each side of the fibre tray using one M4 screw (Table 3-1 Item 2) in the centre of each device.
Figure 2-7
3 Adopting a two-man lift, locate the subrack in its required position and secure it using four M6 mounting screws (in the case of the 19" rack, these screws are not part of the mounting brackets, Table 3-3 Item 8).
4 Fibre guides may now be fitted to the upper edge of the fibre tray and slid into the correct position, one below each optical unit (use of these is covered in Procedure 2-15).
2-14 Installation information
Figure 2-6
323-1061-200 Release 7 Standard
Captive nut and shoulder washer positions
8SU
3U
6VU
Subrack Subrack Subrack
ETSI 19" BT90/91
Mounting screw - Fit captive nut
Installation information 2-15
2
Figure 2-7
Nortel TN-1X Installation Procedures
Subrack brackets and Þbre turning devices (ETSI rack only)
ETSI Mounting Bracket
Fibre Turning Device
Subrack
Left hand side of subrack shown
2-16 Installation information
Insertion and removal of plug-in units and interface modules
323-1061-200 Release 7 Standard
Under normal circumstances the subracks will be delivered with all units Þtted. The only units requiring removal and insertion by the installer are the optical plug-in units which need to be partially withdrawn to connect the optical cords (see Procedure 2-15).
WARNINGRisk of personal injuryWhen working near the top of the Station Interface Area (SIA), care should be taken to avoid scraping your hands on the honeycomb screen above.
CAUTIONRisk of damaging equipmentIf any plug-in units or interface modules require insertion/removal, it is imperative that the following procedure is adopted to avoid damaging the connectors or spring Þngers.
When inserting a plug-in unit, ensure it locates into the BLACK card guide and not the short grey front plate locator to the right of the required position.
Static sensitive devicesThe plug-in units contain static sensitive devices. These devices are sensitive to static electricity and must be protected by special handling and packaging. Refer to the static sensitive handling procedures in ÔDocumentation Overview and Safety, NTP 323-1061-090Õ.
Installation information 2-17
2
Procedure 2-4
Nortel TN-1X Installation Procedures
Insertion and removal of plug-in units and interface modules
Step Action Reference
ÑendÑ
Plug-in UnitsRemoval
1 Release the locking levers on the front of the unit by squeezing the ends of the levers. If required, a free-issue lever tool (code P0875600) can be used to release the levers individually.
Figure 2-8
2 Once the locking levers are released, simultaneously fully retract the top and bottom levers. This will safely disengage the unit from the backplane connector.
3 Slide the unit from the subrack.
Insertion
4 Identify the correct slot position.
5 Ensure that both levers are in the fully open position and slide the unit into the card guide until the levers locate in the extrusion groove.
Figure 2-8
6 Engage the unit in the backplane connector by simultaneously pressing on both levers. DO NOT push on the front cover of the unit.
Figure 2-8
Interface Modules Removal
7 Fully unscrew the central fixing. Figure 2-9
8 Simultaneously operate the top and bottom levers to disengage the module from the backplane.
Figure 2-9
9 Slide the module from the subrack
Insertion
10 Identify the correct position in the subrack.
11 Slide the module into the subrack until initial contact is made with the backplane connector.
12 Without using the leavers, turn the thumbscrew clockwise, by Figure 2-9 hand, until it bottoms out. This occurs when the module is fully inserted.
2-18 Installation information
Figure 2-8
323-1061-200 Release 7 Standard
Plug-in unit insertion/removal
Plug-in unit
Groove location in extrusion
Lever
Close
Open
Lever tool
Use of lever tool (P0875600)
Installation information 2-19
2
Figure 2-9
Nortel TN-1X Installation Procedures
Interface module insertion/removal
Lever
Lever
Central Þxingthumbscrew
Open
Open
2-20 Installation information
Connections - Station Service Module
323-1061-200 Release 7 Standard
The Station Service Module provides connection to:
¥ LAN (Q3 port) (Procedure 2-5)
¥ Rack Alarm Bus (Procedure 2-6)
¥ d.c. power (Procedure 2-7)
The module is located in position T16 (card guide position 80) of the SIA.
Procedure 2-5LAN connections
Step Action Reference
ÑendÑ
1 Identify the Tx/Rx cable assembly (Table 2-6 Item 4).
2 Connect the 15-way male connector to the LAN socket on the Station Service Module. Ensure the retention slide operates to hold the connector in place.
Figure 2-10
3 The female connector at the other end of the assembly connects to the AUI port of the LAN transceiver. This is usually located in a LAN transceiver tray mounted in the same rack as the TN-1X subrack.
Installation information 2-21
2
Figure 2-10
Nortel TN-1X Installation Procedures
Station Service Module layout
RACKALARM
ST
N S
ER
VIC
E M
OD
ULE
25U
JJ00
750G
XC
POWERINPUT
LAN
1
4
3
2
PIN
123456789101112131415
FUNCTION
-12 VPrompt alarmDeferred alarmIn Station alarmNot used0 V0 V0 VNot usedReceive attentionNot usedFault clearNot used0 V0 V
RACK ALARM CONNECTOR PIN-OUT
PIN
123456789101112131415
FUNCTION
Control In Circuit Shield (0V)Control In Circuit A (CI-A)Data Out Circuit A (DO-A)Data In Circuit Shield (0V)Data In Circuit A (DI-A)Voltage Common (VC)Control Out Circuit A (CO-A)Control Out Circuit Shield (0V)Control In Circuit B (CI-A)Data Out Circuit B (DO-B)Data Out Circuit Shield (0V)Data In Circuit B (DI-B)Voltage Plus (VP)Voltage Shield (VS)Control Out Circuit B (CO-B)
POWER CONNECTOR PIN-OUT
FUNCTION
-48 V (fuse 1)0 V (fuse 1)0 V (fuse 2)-48 V (fuse 2)
PIN
1234
LAN CONNECTOR PIN-OUT
109
87
64
53
21
2-22 Installation information
Procedure 2-6
323-1061-200 Release 7 Standard
Rack alarm bus connections
Step Action Reference
ÑendÑ
Figure 2-11Rack alarm bus connection termination
1 Select a loop from the rack alarm bus cable which runs down the right hand side of the rack.
Figure 2-11
2 Loosely assemble the 15-way D-type IDC connector (Appendix A, Table 3-8 Item 7 and Item 8).
Figure 2-11
3 Carefully position the ribbon cable over the IDC pins of the connector such that the red conductor will engage with pin 1. Clamp the ribbon down onto the connector using parallel-jaw pliers.
Figure 2-11
4 Fit the strain relief clamp and shell, and secure the connector assembly to the Station Service Module using the integral screws provided on the shell.
Figure 2-11
Rack alarm bus ribbon loop(existing in rack)
D type shell with integral jack screws
Strain relief clamp
15-way D type IDC connector
IDC connection clamp
Connector(rear view)
Ribbon cable
Red marker to line up with pin 1
3
1
2
4
5
6
7
9
8
10
11
12
13
14
15
Installation information 2-23
2
Nortel TN-1X Installation Procedures
Procedure 2-7Power connections
Step Action Reference
ÑendÑ
Figure 2-12Power connector termination
WARNINGRack fusesIf the parent rack is already powered, the relevant fuses must be removed before Procedure 2-7 is started. The fuses should not be replaced until installation procedures have been completed and the subrack is ready for commissioning.
1 Identify the two blue/black twisted pair power leads for the subrack position. These provide d.c. power for two separate Power Units. The leads are previously installed in the right hand side of the rack.KEEP THE TWO SUPPLIES SEPARATE AT ALL TIMES.
2 Locate the 4-way connector housing and the four Type 2A crimp pins (Appendix A, Table 3-8 Item 5 and Item 6).
Figure 2-12
3 Strip back 7 mm of insulation from each conductor and crimp a pin to each one using a crimp tool and die set (Table 2-1 Item 4 and Item 7).
Figure 2-12
4 Push each pin home into its correct position in the housing. Table 2-10
5 Do NOT plug this connector into the SIM, this will be done at the commissioning stage.
Blue or Black core of power cable
Strip7mm
Connector housing
Note: Pin 1 atbevelled end1
23
4
x4 Crimp pin No 2A
2-24 Installation information
The pin-out details for the power connector are listed in Table 2-10.
323-1061-200 Release 7 Standard
Connections - 75 W Star Card ModuleThe 75 W Star Card Module provides two Type 43 coaxial connectors for the input and output of a 2048 kHz timing signal.
The moduleis located in SIM position T8 (card guide position 40) of the SIA.
Procedure 2-8Connecting the SIM Type 20
Step Action Reference
ÑendÑ
Table 2-10Power connector pin-out details
Pin No. Function Colour
1
2
3
4
-48 V d.c. (fuse 1)0 V (fuse 1)0 V (fuse 2)-48 V d.c. (fuse 2)
blueblackblackblue
1 Identify the two coaxial cords assemblies (Table 2-7 Item 2 or Item 4) for timing signals. The type used will depend on the customer requirements.
2 Connect the Rx Clock cord to the upper connector on the front panel and the Tx Clock cord to the lower connector.
Figure 2-13
3 Dress the cables correctly to maximise vertical airflow and secure using tyraps.
Installation information 2-25
2
Figure 2-13
Nortel TN-1X Installation Procedures
75 W Star Card Module layout
75 W
STA
R C
AR
D25
UJJ
0075
0GW
Z
TXCLK
RXCLK
109
87
64
53
21
2-26 Installation information
Connections - Flexible Access Module
323-1061-200 Release 7 Standard
The Flexible Access Module provides the connections for the Local Craft Access Panel (LCAP). No installation actions are required for the variant 25U JJ00 750 GWX as this is installed in the subrack with no external connections required. Variant 25U JJ00 750 HPD additionally provides interfaces for Þve earth free external alarm inputs which require connection as detailed in Procedure 2-9.
The Flexible Access Module is located in SIM position T1.
Procedure 2-9External alarm connections
Step Action Reference
ÑendÑ
CAUTIONElectrical protectionAll external equipment connected to the External Alarms input must provide protection from mains voltages in accordance with the requirements of EN 41003 for the connection to Telecommunication Network Voltage (TNV) circuits.
1 Install the external alarms cable into the left hand side of the rack. The cable route used should follow the traffic cords installed in Procedure 2-1. The type of cable used is dependent on customer requirements.
2 The mating connector for the ÔEXTERNAL ALARMÕ front panel connector is a female 25-way D-type (Table 2-6 Item 8). Terminate the alarms cable with this connector in accordance with the pin out details given in Figure 2-14.
Figure 2-14
3 Connect the terminated cable to the lower connector on the front panel of the SIM and use tyraps to groom the cable into position.
Figure 2-14
Installation information 2-27
2
Figure 2-14
Nortel TN-1X Installation Procedures
Flexible Access Module - front and side views
LCAP
FLE
XIB
LE A
CC
ES
S M
OD
ULE
25U
JJ00
750H
PD
EXTERNAL ALARM
PIN
1234567891011 & 121314 to 25
FUNCTION
EXTERNAL ALARM CONNECTOR PIN-OUT
External Alarm Input 1
External Alarm Input 2
External Alarm Input 3
External Alarm Input 4
External Alarm Input 5
Not UsedMechanical EarthNot Used
109
87
64
53
21
2-28 Installation information
Connections - 75 W TrafÞc Access Module
323-1061-200 Release 7 Standard
The 75 W TrafÞc Access Module provides sixteen receive and transmit ports for eight 2048 kbit/s tributary circuits. Connection is by sixteen Type 43 coaxial connectors on the module front panel.
The 75 W TrafÞc Access Module can be located in the SIA positions T2, T3, T5, T6, T10, T11, T13, and T14. Two of these modules (Þtted in adjacent slots) provide the necessary connections for a single 2 Mbit/s Tributary Unit in positions S2, S4, S9, and S11 respectively.
Procedure 2-10Connections to 75 W TrafÞc Access Module
Step Action Reference
ÑendÑ
1 Identify the 75 W traffic cords installed in Procedure 2-1.
2 Connect each cord in turn to its respective connector on the Traffic Access Module.
Figure 2-15
3 Ensure that the cords are dressed as described in Procedure 2-1 to achieve the optimum vertical airflow through the subrack.
Figure 2-4
Installation information 2-29
2
Figure 2-15
Nortel TN-1X Installation Procedures
75 W TrafÞc Access Module layout and port allocations
RX
75 W
TR
AF
FIC
AC
CE
SS
MO
DU
LE10
98
76
45
32
125
UJJ
0075
0GV
Z
TX
8
7
6
5
4
3
2
1
16
15
14
13
12
11
10
9
T2 T3 T6T5 T10 T11 T13 T14
S2 S4 S9 S11
Allocated Port Numbers
CorrespondingPlug-in unit position75 W TrafÞc Access Module position
INPUTS
OUTPUTS
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
16
15
14
13
12
11
10
9
16
15
14
13
12
11
10
9
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
16
15
14
13
12
11
10
9
Ports are identiÞed by the slot number and the instance, e.g. S4-7 indicates port 7 for unit in slot S4.
2-30 Installation information
Connections - 120 W TrafÞc Access Module
323-1061-200 Release 7 Standard
The 120 W TrafÞc Access Module provides receive and transmit ports for eight 2048 kbit/s tributary circuits. Connection is by two 25-way D-type connectors on the module front panel, one for transmit ports and one for receive ports.
The 120 W TrafÞc Access Module can be located in the SIA positions T2, T3, T5, T6, T10, T11, T13, and T14. Two of these modules (Þtted in adjacent slots) provide the necessary connections for a single 2 Mbit/s Tributary Unit in positions S2, S4, S9, and S11 respectively.
Procedure 2-11Connections to 120 W TrafÞc Access Module
Step Action Reference
ÑendÑ
Note: * Denotes the quad identiÞcation colour.
1 Locate the 120 W traffic cords installed in Procedure 2-1.
2 Connect each cord in turn to its respective connector on the Traffic Access Module.
Table 2-11Figure 2-16
3 Ensure that the cords are dressed as described in Procedure 2-1 to achieve the optimum vertical airflow through the subrack.
Figure 2-4
Table 2-11Pin-out for 120 W trafÞc cords
Port Pin Colour Quad No.1 9 white
122 blue *
2 12 turquoise
25 violet
3 11 white
223 orange *
4 8 turquoise
20 violet
5 6 white
319 green *
6 5 turquoise
17 violet
7 2 white
414 brown *
8 3 turquoise
16 violet
Installation information 2-31
2
Figure 2-16
Nortel TN-1X Installation Procedures
120 W TrafÞc Access Module layout and port allocation
INPUT
120
W T
RA
FF
IC A
CC
ES
S M
OD
ULE
25U
JJ00
750H
LV
OUTPUT
7
8
6
5
4
1
3
2
15
16
14
13
12
9
11
10
T2 T3 T6T5 T10 T11 T13 T14
S2 S4 S9 S11
2
3
1
4
5
6
8
7
10
11
9
12
13
14
16
15
25
114
13
13
114
25
+ _
CorrespondingPlug-in unit position
TIM 22 position
INPUTS
OUTPUTS
Male
Female
Allocated Port Numbers
7
8
6
5
4
1
3
2
7
8
6
5
4
1
3
2
7
8
6
5
4
1
3
2
15
16
14
13
12
9
11
10
15
16
14
13
12
9
11
10
15
16
14
13
12
9
11
10
2
3
1
4
5
6
8
7
10
11
9
12
13
14
16
15
2
3
1
4
5
6
8
7
10
11
9
12
13
14
16
15
2
3
1
4
5
6
8
7
10
11
9
12
13
14
16
15
Ports are identiÞed by the slot number and the instance, e.g. S4-7 indicates port 7 for unit in slot S4.
109
87
64
53
21
2-32 Installation information
Connections - High Speed TrafÞc Access Module
323-1061-200 Release 7 Standard
The High Speed TrafÞc Access Module provides receive and transmit ports for a 34 Mbit/s Tributary Unit. Connection is by two Type 43 coaxial connectors on the module front panel (RX and TX).
The High Speed TrafÞc Access Module Þts into SIA positions T3, T6, T11, and T14 (backplane slot positions 15, 30, 55, and 70). The allocation of modules to 34 Mbit/s Tributary Units is as follows:
Position T3 34 Mbit/s Tributary Unit Þtted to plug-in unit positionS2 (backplane slot position 15)
Position T6 34 Mbit/s Tributary Unit Þtted to plug-in unit positionS4 (backplane slot position 30)
Position T11 34 Mbit/s Tributary Unit Þtted to plug-in unit positionS9 (backplane slot position 55)
Position T14 34 Mbit/s Tributary Unit Þtted to plug-in unit positionS11 (backplane slot position 70)
Procedure 2-12Connections to High Speed TrafÞc Access Module
Step Action Reference
ÑendÑ
1 Identify the 34 Mbit/s 75 W traffic cords installed in Procedure 2-1.
2 Connect each cord in turn to its respective connector on the High Speed Traffic Access Module.
Figure 2-17
3 Ensure that the cords are dressed as described in Procedure 2-1 to achieve the optimum vertical airflow through the subrack.
Figure 2-4
Installation information 2-33
2
Figure 2-17
Nortel TN-1X Installation Procedures
High Speed TrafÞc Access Module layout
HIG
H S
PE
ED
TR
AF
FIC
AC
CE
SS
MO
DU
LE25
UJJ
0075
0HT
D
MON
TX
RX
109
87
64
53
21
2-34 Installation information
Connections - High Speed Aggregate Module
323-1061-200 Release 7 Standard
The High Speed Aggregate Module provides two Type 43 coaxial connectors for a single 155 Mbit/s (STM-1) electrical aggregate port. The upper connector provides the transmit (output) connection and the lower provides the receive (input) connection.
The High Speed Aggregate Modules may be located in SIA positions T7 and T9. They provide connections for the associated STM-1 Electrical Aggregate Units in positions S6 and S7 respectively.
Procedure 2-13Connections to High Speed Aggregate Module
Step Action Reference
ÑendÑ
1 Identify the High Speed Aggregate Module(s) and the 75 W coaxial cords (Table 2-7 Item 3).
Figure 2-18
2 Connect the transmit cord to the upper connector and receive cord to the lower connector.
3 Secure the cords using tyraps as required, ensuring that the cords are dressed to achieve the optimum vertical airflow through the subrack (see Procedure 2-1).
Installation information 2-35
2
Figure 2-18
Nortel TN-1X Installation Procedures
High Speed Aggregate Module layout
HIG
H S
PE
ED
AG
G M
OD
ULE
25U
JJ00
750G
YZ
TX
RX109
87
64
53
21
2-36 Installation information
Connections - High Speed Tributary Module
323-1061-200 Release 7 Standard
The High Speed Tributary Module provides two Type 43 coaxial connectors for a single 155 Mbit/s (STM-1) electrical tributary port. The upper connector provides the transmit (output) connection and the lower connector provides the receive (input) connection.
The High Speed Tributary Modules may be located in SIA positions T3, T6, T11, and T14. They provide connections for the associated STM-1 Electrical Tributary Units in positions S2, S4, S9 and S11 respectively.
Procedure 2-14Connections to High Speed Tributary Module
Step Action Reference
ÑendÑ
1 Identify the High Speed Tributary Module(s) and the 75 W coaxial cords (Table 2-7 Item 3).
Figure 2-19
2 Connect the transmit cord to the upper connector and receive cord to the lower connector.
3 Secure the cords using tyraps as required, ensuring that the cords are dressed to achieve the optimum vertical airflow through the subrack (see Procedure 2-1).
Figure 2-4
Installation information 2-37
2
Figure 2-19
Nortel TN-1X Installation Procedures
High Speed Tributary Module layout
HIG
H S
PE
ED
TR
IB M
OD
ULE
25U
JJ00
750G
WY
TX
RX109
87
64
53
21
2-38 Installation information
Connections - optical aggregate/tributary units
323-1061-200 Release 7 Standard
Procedure 2-15 is applicable to all optical aggregate and optical tributary units. Connections to the units are achieved PC-FC connectors Þtted to ruggedised Þbre cords. Attenuators are not required.
Figure 2-20Typical layout of optical units
CAUTIONOptical Þbres and connectorsWhen dressing Þbres, take care not to exceed the minimum bend radius (typically 35 mm) and not to overtighten tyraps used for dressing as damage may result
Refer to the warnings and cautions detailed in the ÔAbout this documentÕ section of this NTP for optical connector/Þbre handling and optical safety before starting this procedure.
Unit Lock/Ejector
ProtectiveCoverClosed Open
STM-1OPT
AGG
FAIL
SK
SK
SK
OpticalConnectors
LASERON TEST
Installation information 2-39
2
Procedure 2-15
Nortel TN-1X Installation Procedures
Connections to optical units
Step Action Reference
ÑcontinuedÑ
1 Run the optical cords into the subrack as follows:
ETSI RACKa. Undo the subrack mounting screws and slide the
subrack out until it reaches the slide-mount stops.
b. Run the cords down the designated fibre voids past thesubrack.
c. Open the fibre tray cover and feed the cords into thetray via the fibre turning device. Allow sufficient lengthfor terminating on the optical units.
d. Fit one fibre guide per cord to the tray and slide into thecorrect position.
e. Fit the cords into their fibre guide and go to Step 2.
OTHER RACK TYPESa. Run the cords down the designated fibre voids past the
subrack.
b. Open the fibre tray cover and feed the cords into thetray. As there are no fibre turning devices, extremecare should be taken not to exceed the minimumbending radius when routing the cords into the subrack.
c. The desired position should be maintained by lightlycleating with tyraps as required.
d. Fit one fibre guide per cord to the tray and slide into thecorrect position.
e. Fit the cords into their fibre guide and go to Step 2.
Figure 2-21
Figure 2-21
2 Remove the dust caps and clean the optical connectors using the cleaning kit (Table 2-1 Item 3).
3 Inspect the optical connectors using the microscope (Table 2-1 Item 2) and repeat Step 2 if necessary.
4 Using the top and bottom ejector levers, disengage each optical unit from the backplane and pull it forward sufficiently to enable the connector cover to be opened.
Figure 2-20
2-40 Installation information
Procedure 2-15
323-1061-200 Release 7 Standard
Connections to optical units (continued)
Step Action Reference
ÑendÑ
Figure 2-21Optical Þbre routing
5 Connect the optical cords to their corresponding connectors on the optical units, ensuring that the key-way has engaged before tightening (upper connector Rx, lower connector Tx).
Figure 2-20
6 Close the optical connectors covers. Figure 2-20
7 Reinsert the optical units by fully opening the ejector levers, pushing the unit until the levers locate in the extrusion groove and close both levers simultaneously. Do not push on the front panel.
Figure 2-20
8 Taking care not to trap any optical cords, slide the subrack back into the rack and secure it.
9 Close the fibre tray cover.
Fibre Guidesclip to top railof fibre trayand slide tocorrect positionbelow optical PIU
View from Below
Subrack Sideplate
Installation information 2-41
2
Single Þbre working mode
Nortel TN-1X Installation Procedures
When operating in the single Þbre optical mode, 2-1 optical converter boxes (couplers) are used to perform the conversion between two Þbre and single Þbre working. The 2-1 optical converter box (NTKD0100, Table 2-6 Item 9) can be Þtted in the Þbre tray as shown in Figure 2-22. Up to 4 converter boxes can be Þtted in a TN-1X subrack.
Figure 2-22Single Þbre working couplers
Single Fibre to Connecting Mux
2-1 OpticalConverter
Box
Fibre Tray
Tx
RxOn OpticalUnit
2-42 Installation information
Local Craft Access Panel
323-1061-200 Release 7 Standard
The Local Craft Access Panel (LCAP) provides a 25-way D-type connector for the CAT local terminal and a BT style telephone socket for the EOW handset. These connectors are located behind a hinged cover on the left of the panel.
Neither of the above connectors are required to be connected during installation of the subrack.
A second 25-way D-type connector, on the rear of the LCAP, provides connection to the Flexible Access Module.
No installation actions are required.
Figure 2-23LCAP layout
PIUArea
FibreTray
LCAP
SIA
Hinged Front Panel
CATTConnector
Traffic MonitorSockets
EOWHandsetSocket
REC ATTled
ALARMled
ALM ACKled
ESD(Wrist Strap
Socket)
Detail BehindHinged Panel
Installation information 2-43
2
EOW telephone
Nortel TN-1X Installation Procedures
The Engineering Order Wire (EOW) handset provides engineers access to the EOW speech system. The handset and its mounting bracket are supplied as a separate kit (see Appendix A, Table 3-9).
Procedure 2-16EOW telephone mounting
Step Action Reference
ÑendÑ
Figure 2-24EOW handset stowage
1 Use a suitable solvent to clean the underside of the LCAP.
2 Remove the paper from the adhesive pad on the bracket.
3 Position the bracket in the centre of the LCAP and align the tongue of the bracket on the rear of the LCAP.
Figure 2-24
4 Apply firm pressure for at least 5 seconds to ensure good adhesion.
5 Place the handset face down in the bracket and store the telephone plug in the retainer.
Figure 2-24
LCAP
FibreTray
EOWHandset
ServiceInterfaceArea
2-44 Installation information
Fitting inÞlls, covers and designation labels
323-1061-200 Release 7 Standard
A subrack cover kit (25S KM00 750 HFL) is supplied with each subrack variant (see Appendix A Table 3-6). If the equipment is mounted in an NT ETSI rack, subrack inÞll panels are required (part of 25S KM00 750 HFL kit).
If the equipment is mounted in an NT ETSI rack, ÔdummyÕ covers can be Þtted, if required, to improve aesthetics (see Appendix A Table 3-7).
Procedure 2-17Fitting the inÞlls, covers and designation label
Step Action Reference
ÑendÑ
1 Identify the Station Interface Area cover assembly (this item is not used with 19" racks).
Figure 2-25
2 Ensure the locking screws are in the open position. Figure 2-25
3 Pull back the left and right latches simultaneously and locate the cover over the Station Interface Area of the subrack.
4 Release the latches and check that the cover is correctly located.
5 Turn the left and right locking screws counter-clockwise and clockwise respectively.
Figure 2-25
6 Identify the infill panels. These are used on ETSI racks only to conceal mounting flanges.
Figure 2-26
7 Locate each infill onto the mounting studs on the mounting flanges and firmly push it home until flush with the surrounding surfaces.
Figure 2-26
8 Identify the sheet of designation labels, listed in the installation kit parts lists (Appendix A Table 3-1 to Table 3-5).
9 Select the appropriate label corresponding to the position in which the subrack is mounted and fit it to the right hand side of the fibre tray cover as shown.
Figure 2-26
10 For ETSI racks only, when all the equipment is installed, any empty spaces can be fitted with dummy panels if required for aesthetic purposes (Appendix A Table 3-7).
11 Fit M6 cage nuts to the rack and secure brackets to these positions using M6 screws.
Figure 2-27
12 Push-fit the dummy covers onto the bracket studs (covers of 10 SU and above are also equipped with spring handles).
Figure 2-27
Installation information 2-45
2
Figure 2-25
Nortel TN-1X Installation Procedures
Station Interface Area cover assembly
northerntelecomS/DMSTransportNode
To open
Lock position
To open
Lock position
Locking screw
Latch (closed position)
2-46 Installation information
Figure 2-26
323-1061-200 Release 7 Standard
Fibre tray cover, subrack label and inÞll panels
Figure 2-27Fitting dummy covers
end of chapter
2M TRIB(75 W)
P/LOADMNGR
POWERUNIT
SBRKCONT
STM1OPTAGG
Note: Shown with SIA cover removed
STM1OPTAGG
P/LOADMNGR
POWERUNIT
BLANKMODULE
BLANKMODULE
FAIL FAIL FAIL FAIL FAIL FAIL FAIL FAIL FAIL FAIL FAIL
SHELFPOSITION
21
RECEIVE ATT
25U
JU00
750G
XG
BLANKMODULE
ALARM ALM ACKESD
2M TRIB(75 W)
2M TRIB(75 W)
2M TRIB(75 W)
1 2 3 4 5 6 7 8 9 10
11 12
13
14
25U
JU00
750G
XG
25U
JU00
750G
XG
25U
JU00
750G
XG
25R
BN
0002
1AA
B
25R
BN
0002
1AA
B
25R
BN
0002
1AA
B
25U
TM
0075
0GW
A
25U
TM
0075
0GW
A
25U
PJ0
0750
GX
F
25U
PJ0
0750
GX
F
25U
PW
0075
0HA
Y
25U
PW
0075
0HA
Y
25U
MN
0075
0G
XD
Fibre Tray
SubrackDesignationLabel
SHELFPOSITION
21
Infill Panel
Bracket (2 Posns)with cover mountingstuds)
Dummy Cover
3-1
3Appendix A: Installation kits parts list 3-
Nortel TN-1X Installation Procedures
Table 3-1Installation kit for NT ETSI rack (25S KM00 019 AAE)
Item Code Description Qty
1 25P NT90 021 AAA M6 captive nut (ETSI) 4
2 99P SW90 056 HAJ Screw, M4 x 8 mm, recessed pan head S/ST 10
3 99P WX90 019 HAA Washer, lock, crinkle, M4 S/ST 8
4 25P LB00 021 AEJ Subrack designation label, Þbre tray 1
5 25P GD00 021 AAA Fibre guide 4
6 25P SE00 021 AAA Fibre tray corner 2
7 25R BT00 021 ABQ ETSI Mounting Bracket Assembly 2
Table 3-2Installation kit for 23" rack (for example, OPAC cabinet)
Item Code Description Qty
1 25R BT00 021 ABR 23" mounting bracket assembly (left or right side) 2
2 25P GD00 021 AAA Fibre guide 4
3 25P SE00 021 AAA Fibre tray corner 2
3-2 Appendix A: Installation kits parts listA
Table 3-3
323-1061-200 Release 7 Standard
Installation kit for 19" rack (25S KM00 750 HNZ)
Item Code Description Qty
1 25R BT00 021 AAW 19" mounting bracket assy, right-hand side 1
2 25R BT00 021 AAX 19" mounting bracket assy, left-hand side 1
3 25P NT90 021 AAA M6 captive nut, ETSI 4
4 99P WX90 019 HAA Washer, lock, crinkle, M4 S/ST 8
5 99P SW90 056 HAJ Screw, M4 x 8 mm, recessed pan head S/ST 8
6 25P GD00 021 AAA Fibre guide 4
7 25P LB00 021 AEJ Subrack designation label, Þbre tray 1
8 99P SW90 053 LAN Screw M6x12, slotted pan head, S/ST 4
Table 3-4Installation kit for Rack 91 (25S KM00 750 HPB)
Item Code Description Qty
1 25R BT00 021 AAJ Mounting bracket assy, Rack 91 2
2 99P WX90 019 HAA Washer, lock, crinkle M4 S/ST 8
3 99P SW90 056 HAJ Screw, M4 x 8 mm, recessed pan head S/ST 10
4 25P GD00 021 AAA Fibre guide 4
5 25P SE00 021 AAA Fibre tray corner 2
6 25P LB00 021 AEJ Subrack designation label, Þbre tray 1
Table 3-5Installation kit for Rack 90 (25S KM00 750 HPC)
Item Code Description Qty
1 25R BT00 021 AAM Mounting bracket assy (Rack 90) 2
2 99P WX90 019 HAA Washer lock crinkle M4 S/ST 8
3 99P SW90 056 HAJ Screw M4 x 8 recessed pan head S/ST 10
4 25P GD00 021 AAA Fibre guide 4
5 25P SE00 021 AAA Fibre tray corner 2
6 25 P LB00 021 AEJ Subrack designation label Þbre tray 1
Appendix A: Installation kits parts listA 3-3
3
Nortel TN-1X Installation Procedures
Table 3-6Subrack cover kit (25S KM00 750 HFL)
Item Code Description Qty
1 25P LB00 021 ACT Label Ð PEC Strip Upper 1
2 25P LB00 021 ACV Label Ð PEC Strip Lower 1
3 25P GD00 021 AAC SIM Card Guide 2
4 25P GD00 021 AAB SIA Card Guide 2
5 25P GD00 021 AAH SIA Slide (LH) 1
6 25P GD00 021 AAG SIA Slide (RH) 1
7 A0609505 Rivscrew ADVEL 1712-3010 8
8 25R CV00 021 AAA Station interface cover assembly 1
9 25R CV00 021 ABA Fibre tray front cover assembly 1
10 25P CV00 021 AAE L & R Subrack infills 2
Table 3-7NT ETSI rack dummy cover kits
Code Description
25S KM00 750 HPD ETSI rack dummy cover kit, 3 SU
25S KM00 750 HPE ETSI rack dummy cover kit, 4 SU
25S KM00 750 HPF ETSI rack dummy cover kit, 7 SU
25S KM00 750 HPG ETSI rack dummy cover kit, 10 SU
25S KM00 750 HPH ETSI rack dummy cover kit, 11 SU
25S KM00 750 HPJ ETSI rack dummy cover kit, 13 SU
25S KM00 750 HPK ETSI rack dummy cover kit, 21 SU
3-4 Appendix A: Installation kits parts listA
Table 3-8
323-1061-200 Release 7 Standard
end of chapter
TN-1X installation kit (25S KM00 807 ABL)
Item Code Description Qty
1 25S KM00 802 AAV Plain label kit (152 off) 1
2 25P CL00 801 QOO Tyrap large 20
3 25P CL00 008 ABC Tyrap small 15
4 25C PR13 001 GBG Fuse, size 0, 7 A 4
5 25P SK00 001 AAF Skt moulding, BT 237, 4-way (d.c. power) 1
6 25P CN00 002 AAG(see Note)
Pin, crimp, No 2A (d.c. power) 6
7 A0602517 Connector, female, 15-way D-type, IDC 1
8 25P SV00 005 ABL Shell, 15-way D-type 1
Note: Pins for 1.5 mm2 cables are supplied with the rack.
Table 3-9EOW handset kit (25S KM00 750 HZM)
Item Code Description Qty
1 25R BT00 021 ABH Bracket assembly EOW handset mounting 1
2 25Y TN00 750 AAA EOW DTMF telephone handset assembly 1
3 25P JC00 750 AAD EOW installation instruction sheet 1
4-1
Index 4-
120 W TrafÞc Access Moduleconnections 2-30D
4
Nortel TN-1X Installation Procedures
layout 2-31port allocations 2-31
19" rackinstallation kit 3-2installing subrack 2-13trafÞc cables 2-8
23" rackinstallation kit 3-1
75 W Star Card Moduleconnections 2-24layout 2-25
75 W TrafÞc Access Moduleconnections 2-28layout 2-29port allocations 2-29
Ccable
dressing 2-11labelling 2-11routing 2-8, 2-9
cautions xviiconnections
120 W TrafÞc Access Module 2-3075 W Star Card Module 2-2475 W TrafÞc Access Module 2-28Flexible Access Module 2-26High Speed Aggregate Module 2-34High Speed TrafÞc Access Module 2-32High Speed Tributary Module 2-36LAN 2-20optical aggregate units 2-38optical tributary units 2-38power 2-23rack alarm bus 2-22Station Service Module 2-20
contents of package 1-2
delivery of package 1-1designation labels 2-44disposal of packaging 1-2dressing cables 2-11dummy covers 2-44
EEOW telephone 2-43equipment
core items 2-2plug-in units 2-2Service Interface Modules 2-3TrafÞc Interface Modules 2-3
FÞbre
labelling 2-11routing 2-40see also cable
Þbre turning devices 2-13, 2-15Flexible Access Module
connections 2-26layout 2-27
Hhandling of package 1-1High Speed Aggregate Module
connections 2-34layout 2-35
High Speed TrafÞc Access Moduleconnections 2-32layout 2-33
High Speed Tributary Moduleconnections 2-36layout 2-37
4-2 Index
I unpacking 1-2
323-1061-200 Release 7 Standard
inÞll panels 2-44installation items 2-4installation kit
19" rack 3-223" rack 3-1NT ETSI rack 3-1, 3-2, 3-3, 3-4Rack 91 3-2, 3-3, 3-4
installation procedure 2-6installation tools 2-1installing
interface modules 2-16plug-in units 2-16subrack 2-13trafÞc cables 2-8
interface modulesinsertion/removal 2-16
Llabelling
cables 2-11Þbres 2-11
LAN connections 2-20LCAP, see Local Craft Access PanelLocal Craft Access Panel 2-42
NNortel service desk xiiiNT ETSI rack
dummy cover kits 3-3installation kit 3-1, 3-2, 3-3, 3-4installing subrack 2-13trafÞc cables 2-8
Ooff-loading of package 1-1OPAC cabinet 3-1optical aggregate units
connections 2-38optical tributary units
connections 2-38
Ppackage
contents 1-2delivery 1-1disposal 1-2handling 1-1storage 1-1
plug-in units 2-2insertion/removal 2-16
port allocations120 W TrafÞc Access Module 2-3175 W TrafÞc Access Module 2-29
power connections 2-23
RRack 90
installing subrack 2-13trafÞc cables 2-8
Rack 91installation kit 3-2, 3-3, 3-4installing subrack 2-13trafÞc cables 2-8
rack alarm busconnections 2-22
routingcables 2-8, 2-9Þbre 2-40
SService Interface Modules 2-3SIA, see Station Interface AreaSIM, see Service Interface Modulessingle Þbre working 2-41Station Interface Area 2-16, 2-44Station Service Module
connections 2-20layout 2-21
storage of package 1-1subrack
brackets 2-15cover kit 3-3, 3-4Þbre turning devices 2-13, 2-15installation items 2-4installation procedure 2-13layout 1-4
support hotline xiii
Ttechnical support xiiiTIM, see TrafÞc Interface Modulestools
installation 2-1trafÞc cables
installation 2-8TrafÞc Interface Modules 2-3
Index 4-3
4
U
Nortel TN-1X Installation Procedures
unpacking of package 1-2
Wwarnings xvii
International Broadband Networks (Dept18600)Nortel plcOakleigh Road SouthLondon, N11 1HB
So far as Northern Telecom is aware the contents of this document are correct. However, such contents have been obtained from a variety of sources and Northern Telecom can give no warranty or undertaking and make no representation as to their accuracy. In particular, Northern Telecom hereby expressly excludes liability for any form of consequential, indirect or special loss, and loss of data, loss of proÞts or loss of business opportunity, howsoever arising and whether sustained by the user of the information herein or any third party arising out of the contents of this document.
SDH TRANSMISSION
Nortel TN-1X Installation Procedures
Copyright ã 1995, 1996, 1997 Northern Telecom
The copyright of this document is the property of Northern Telecom. Without the written consent of Northern Telecom, given by contract or otherwise, this document must not be copied, reprinted or reproduced in any material form, either wholly or in part, and the contents of this document, or any methods or techniques available therefrom, must not be disclosed to any other person whatsoever.
NORTHERN TELECOM CONFIDENTIAL: The information contained in this document is the property of Northern Telecom. Except as speciÞcally authorized in writing by Northern Telecom, the holder of this document shall protect same in whole or in part from disclosure and dissemination to third parties and use same for evaluation, operation, and maintenance purposes only.