Download - Toshiba 250MW Generator and Steam Turbine
![Page 1: Toshiba 250MW Generator and Steam Turbine](https://reader030.vdocument.in/reader030/viewer/2022012711/61aad4680043f64f505840d1/html5/thumbnails/1.jpg)
Toshiba 250MW Generator and Steam Turbine
Generator 250MW
18kV @ 50Hz
8,019A
3000rpm
Air-Water Cooled
Turbine Condense and extract
104 bar inlet pressure
215MW output
10 bar @ MP1
22 bar @ MP2
4.5 bar @ LP
0.4 bar @ feed water
45 kg/s steam flow rate at minimum load with no extractions and bleeds only
270 kg/s steam flow rate at maximum load
Condenser Average temperature 17 Degrees Celsius
Minimum temperature 15 Degrees Celsius
Maximum temperature 25 Degrees Celsius
![Page 2: Toshiba 250MW Generator and Steam Turbine](https://reader030.vdocument.in/reader030/viewer/2022012711/61aad4680043f64f505840d1/html5/thumbnails/2.jpg)
Maintenance Procedure Regularly maintained with silica gel
Will be prepared for shipping.
Freight Approximate total shipping weight 2,800 tonnes
Total number of items: 74
Condensor Covers (Top): 2
Weight of each Condensor cover: 15 tonnes
Total weight of Condensor covers: 30 tonnes
Number of Condensers: 2
Weight of each Condensor: 85 tonnes
Total weight of Condensors: 170 tonnes
Weight of Turbine: 268 tonnes
Weight of Generator: 277 tonnes
Total weight: 795 tonnes
![Page 3: Toshiba 250MW Generator and Steam Turbine](https://reader030.vdocument.in/reader030/viewer/2022012711/61aad4680043f64f505840d1/html5/thumbnails/3.jpg)
![Page 4: Toshiba 250MW Generator and Steam Turbine](https://reader030.vdocument.in/reader030/viewer/2022012711/61aad4680043f64f505840d1/html5/thumbnails/4.jpg)
![Page 5: Toshiba 250MW Generator and Steam Turbine](https://reader030.vdocument.in/reader030/viewer/2022012711/61aad4680043f64f505840d1/html5/thumbnails/5.jpg)
![Page 6: Toshiba 250MW Generator and Steam Turbine](https://reader030.vdocument.in/reader030/viewer/2022012711/61aad4680043f64f505840d1/html5/thumbnails/6.jpg)
![Page 7: Toshiba 250MW Generator and Steam Turbine](https://reader030.vdocument.in/reader030/viewer/2022012711/61aad4680043f64f505840d1/html5/thumbnails/7.jpg)
![Page 8: Toshiba 250MW Generator and Steam Turbine](https://reader030.vdocument.in/reader030/viewer/2022012711/61aad4680043f64f505840d1/html5/thumbnails/8.jpg)
![Page 9: Toshiba 250MW Generator and Steam Turbine](https://reader030.vdocument.in/reader030/viewer/2022012711/61aad4680043f64f505840d1/html5/thumbnails/9.jpg)
![Page 10: Toshiba 250MW Generator and Steam Turbine](https://reader030.vdocument.in/reader030/viewer/2022012711/61aad4680043f64f505840d1/html5/thumbnails/10.jpg)