FOURTH INTERNATIONAL CONFERENCE
on
UNCONVENTIONAL ELECTROMECHANICAL
AND ELECTRICAL SYSTEMS
21-24 June 1999
St. Petersburg, Russia
Organized by:
St. Petersburg State Technical University, St. Petersburg, Russia
Institute of Electrical Engineering, Technical University of Szczecin, Szczecin, Poland
Co-organized by:
Petersburg State University of Means of Communication
Division of Electrical Power Engineering, Russian Academy of Sciences
Committee for Electrical Engineering, Polish Academy of Sciences
International Academy of Electrotechnical Sciences
Polish Society for Theoretical and Applied Electrical Engineering
Polish Section of IEEEIEEE Power Engineering Society (St. Petersburg Chapter)
VOLUME 3 of 3
Pages 761 -1428
S Z C Z E C I N 1999UB/TIB Hannover122 633 040
89
CONTENTS COflEPHCAHHE
VOLUME 3
Section 3 New materials and modern technologies used in electrical engineering
CeKUHH 3 H o s b i e Marepajibi H coBpeiueHHbie TexHOJiomiH npmvieHHeMbie B
3.leKTpOTe\HHHeCKOH npOMWUIJICHHOCTH
p./CTp.
Modelling of wave process in the electric motor stator winding taking into account itsdiscontinuiti. The solution of direct and inverse problem.Mo,gejiHpoBaHHe BOJIHOBMX npoueccoB B cTaTopHwx o6MOTKax ajieicrpHHecKHx MauiHH npHH3MeHeHHH noroHHwx napaMeTpoB CKamcaMH. PeuieHHe npsiMOH H o6paTHoft 3a^aHHV.P.Berzan 785
Electric properties of LPDE+PET recyclate3jieKrpHHecKne cBOHCTBa peuHKJWTa YY3BJX + n3T<X>J.Bursa 791
Model of medium voltage metal oxide arresterMoaejib OIlHa ana cpe/uutx HanpsuKeHHiiKChrzan, Z.Pohl, J.Furgal 795
Laminar model of electric machine magnet operationJlaMHHapHax Moaejib po6oTW nocTOHHHbix MarHHTOB B aneicrpHHecKHx MauiHHaxLDudzikowski 801
Method of including thermal effect in permanent-magnet commutator machine analysisMeroa onpcuejieHHH BJHWHHH TeMnepaTypw Ha napaMeTpw MarHHTO3JieicrpnHecKHXKOJlIieKTOpHblX MaUIHH
LDudzikowski, S.Kubzdela 807
Control of cooling process in vacuum furnaceYnpaBJieHHe npoueccoM oxJiaameHHa BaKyyMHoii nennM.Durnas, Z.Zarzycki 813
The products of chemical degradation of PET as new hardeners of epoxy compositionsIIpOflyKTbl XHMHHeCKOH flerpaflailHH I I 3 T KaK HOBbie OTBepflHTejTH 3nOKCHflHbIX KOMnO3HUHH
E.Fabrycy, K.Gorqcy, J.Michalski 819
Electrostatic safety of operations on transporting and storage of petroleum3jieKTpocTaTHMecKa» 6e3onacHocTb onepauHH no TpaHcnoprHpoBice H xpaHeHHK)He<j)TonpoflyKTOBV.L.Galka, K.B. Shchiglovskfy 825
The permanent magnet equipment for modern buildingsO6opyaoBaHHe Ha nocToaHHbix ManiHTax unit coBpeMeHHoro wiuiHUtaB.S. Glagolev, S.E.Kitanov, E.A.Mahova, A. V.Podolskiy 829
Sensors for trains automatic motion systemsflarMHKH ofl% aBTOMaTH3HpoBaHHbix CHCTeM flBHJKeHHii penbcoBoro TpaHcnopTa
B.S.Glagolev, S.E.Kitanov, E.A.Mahova, A. V.Podolskiy, S.A.Gulin 835
772
Characteristics of process as membership functions in polymer thick film sensorsXapaicrepHCTHKH npoueccoB B TOHKHX nariHMepHbix njieHKax <t>yHKU.HOHHpyK>iu.Hx ceHcopoBT.Habdank - Wojewodzki 841
Influence of temperature on sensor friction nodeBjiHsmne TeMnepaTypw Ha aaTHHK y3Jia TpeHHHT.Habdank - Wojewodzki, W.Rakowski, S.Zimowski, S.Habdank - Wojewodzki 847
Optimized quality using realtime simulation technology in logidyn D2OnTHMH3au.HJi KanecTBa c Hcnojib3OBaHHeM cHMMynauHH TexHOJiorHH B peanbHOM BpeMeHHA.Hambrecht 853
The influence of magnetohydrodynamic properties of the liquid metal rotor on the inductionelectrical machine parametersBjiHHHHe MarHHTOrHnpoflHHaMHnecKHX cBoftcTB >KHHKOMeTannHHecKoro poTopa HaXapaKTepHCTHKH HHAyKUHOHHOH 3JieKTpHHeCK0H MaUlHHUR.M.Hristinich, V.N.Timofyeyev, M.V.Piervuhin 857
Conception of adapting GIS for radar systemHaea HcnojnoBaHHH FHC B paflHOJioKauHHJ.Januszewicz, W.Kocanda, M.Koselski, F.Mroczko 863
Curved high-order finite elements for numerical solution of the Helmholtz equation incomplicated geometriesHcKpHBJieHHbie BbicoKoynopirflOHHbie KOHeiHbie 3JieMeHTw flna HHCjieHHoro peuieHHaypaBHeHHft Fejibivironbua npn CJIOJKHOH reoMeTpHH cpeflbiJ.S.Juntunen 867
The semiconductor corona generator for clearing gass pollutionnojiynpoBOflHHKOBbitt KopoHHbift reHepaTop ana OHHCTKH 3arpa3HeHHwx ra3OBS.Kalisiak, W.Paterkowski 873
Hydrophobicity of polymer recycling materialsFHflpo4)o6HOCTb nojiHMepHbix MaTepaanoB
E.l.Lipinski,J.Michalski 877
The influence of moisture on polarization currents in polyurethane recyclateBjiHHHHe B^ajKHOCTH Ha TOK nOJI«pH3aUHH B nOJIHypeTaHOBOM peUHWTSITe
M.Michalczuk 883
The influence of selected ageing factors on electrical and mechanical properties of recyclatestype PS/PEBjiHSHHe HeKOTopwx (JiaKTopoB CTapeHHa Ha 3JieicrpKHecKHe H MexaHHiecKHe CBoficTBa
peuHwisrroB THna nC/II3J.Michalski, Z.Tartakowski 889
Diagnostic method for power statics capacitorMeTOfl flHarHocTHKH ana MomHoro craTHwecKoro KOHfleHcaTopaBAMokin, V.V.Grabko, M.P.Botsula 893
The ceramic wire and solenoid from high-temperature YTTRIA superconductorKepaMHnecKHH npOBoa H COJICHOHH H3 BbicoKoreMnepaTypHoro CBepxnpoBOAHHKaHTrpHeBoro cocraBaY.A.Polonskiy, S.S.Ordanyan, T.S.Basalayeva 899
The Stirling engine models for educational purposesMoflenH flBHraT&nJi CmpjiMHra B npouecce o6yMeHH»J.Pomianowski 903
773
Intercontact space circuit parameters of a sliding contact brush-collectorIlapaMeTpbi MeaacoHTaicrHoro npocTpaHCTBa B CKOJib3aineM KOHTaicre meTKa-KOJuieicropW.Rafalski, LMoson 909
Electric characteristics of polyblend PA6-PBT3jieKTpHHecKHe CBOHCTBa nojiHMepHbrx cMeceii nojiHaMHfla I IA6
c nojiH6yTHJieHTepe(|>TajiaTOM
LSubocz '. 9 1 5
TSC in polyimide films with different polarization timeTCT nojiHHMHflHbix iweHOK npn paanHHHbix BpeMeHax narcapiraauHHJ.Subocz, A. Volozhin 919
Electroinsulating composites materials by recycling polymers3jieiapoH3OJiHUH0HHbie KOMno3HTHbie MaTepnajibi H3 nonHMepoB peuHKUHHra
Z.Tartakowski, J.Michalski 925
The localisation of insulation defects in stator winding of electric machineJl0K3JiH3auna ,ae<j)eKTOB H3OJWUHH B CTaTopHott O6MOTKC aneicrpHHecKOH MauiHHbi
M.Tirfu 931
Magneto straining materials - a new actuator materials for electromechanical devicesMarHHTHO ae(j)opMHpyeMbie MaxepHanw - HOBwe MaTepnanbi AJIH 3JieicrpoMexaHHHecKoronpeo6pa3OBaTejwK.VUakko, T.Jokinen 937
Improvement of the impregnation process for insulation systems of high-voltage electricalmachinesCoBepUieHCTBOBaHHe TeXHOJIOrHH nponHTKH H 3 O J I H U H O H H W X CHCTeM BblCOKOBO^bTHblX
N.M. Vakser, V. V.Starovoytenkov, V.K.Stupina 943
Some electrical properities of PET with ferrocene units3neicrpHHecKHe CBottcTBa nneHOK H3 4>eppoueHCOflep>Kamero nojiH3THjieHTepe<j)TajiaTaA.VoIozhin, J.Subocz 949
Influence of buffer layer on the dynamic characteristics of superconducting switchesBjinaHHe 6y«J>epHoro cjioa Ha /jHHaMHwecKHe xapaicrepHCTHKH CBepxnpoBOflHHKOBbix lauoMeflJ.Waskiewicz ~ 953
Polivynylidene fluoride cable as an acoustic emission transducer at low temperaturesnojiHBHHHJKJrropHZiHbiH Kafeib KaK aKycTHMecKHfi npeo6pa3OBaTejib npH HH3KOHTeMnepaTypeL.Woiny, M.Borowicz, A.Kisiel 959
Acoustic emission signals induced by temperature superconducting transition in ChevrelphasesAKycTHHecKaa SMHCcna CHrnanoB npn TeMnepaTypHbix 4>a3OBbix nepexoaaxCBepxnpoBOAHiucaLWozny, P.Lubicki 965
The perspectives of application of transformers with high-temperature superconducting (hts)windingsFlepcneKTHBU npHMeHeHHa TpaHC<j>opMaTopoB c oGinoTKaMH H3 BwcoKOTeMnepaTypHbixCBepxnpoBO^HHKOB (BTC)K.Zakrzewski 969
Designing ellipsoidal reflector for coupling a cylindrical light source with an optical fibreFlpoeKTHpoBaHHe sjumncoHOanbHoro pectwieKTOpa ana CBX3H uwiHHApHMecKoro HcroiHHKaCBera c onnnecKHM BOJIOKHOMKZaremba 975
774
Increasing luminaire efficiency by using a fluorescent lamps with an internal reflectorYBejiHieHHe CBCTOBOH 3<jx{>eKTHBHocTH npn Hcnojib3OBaHHH (JmyopecueHTHNxC BHyTpeHHHM pe(})JieKTOpOMK.Zaremba 981
Properties of plasma deposited PTFE thin filmsCBoftcTBa riiia3MeHHo HanbuieHHofi ITTO3 TOHKOH ruiemcHJ.Ziaja, Z.Zubel 985
Influence of chemical modification on dielectric properties of thermoplastic elastomersBjIHflHHe XHMHHeCKHX MOflH(j)HKaU,HH Ha iUBJieiOpHHeCHe CBOHCTBa TepMOrUiaCTHHHWXsjiaeroMepoBZ.Zubel, D.Zuchowska 989
Section 4 Special electrical power engineering systems
4 CneunajibHbie sjieicrposHepreTimecKHe
p./cTp.
Optimization questions of transformations for impulsed technologiesBonpocw onTHMH3auHn npeo6pa3OBaTe.neH RJIS HMnyjibcHbix TexHonorHHHR.A.Ahmerov, T.P.Kostyukova, L.E.Roginskaya 995
Specification of operation conditions in electrical power supply network to the large groupsof non-linear single-phase low-power loads
pa6orbi sjieioposHepreTHMecKHX cHereM npn HanHMHH 6ojibuioro KojiHnecTBaefiHbix oflHO(J)a3Hbix Ma^oMomHbix Harpyjoic
J.Adamska, A.Handke 1001
A system for scientific research of microwave heatingCHCTeiua HayHHHx HccjieaoBaHHH MHKpoBOJiHOBoro HarpeBaW.Adamski, M.Kitlinski 1007
Probability-theoretic fundamentals of designing for testing large power systemsTeopeTOKO-BeposTHOCTHoe npoeKTHpoBaHHe HcnbrraHHii 6ojibuiHx sjieicrpHMecKHx CHCTCM
LArefiev, LMartyshchenko 1013
Construction of wind power plant-engineering strategy and technical aspects on the groundsof Nowogard's experienceCrpaTerHiecKHe H TexHHiecicMe acneicrbi KOHCTpyHpoBaHHH BeTposHepreTHMecKHx ycrraHOBOKHa onbrre HoBorapflCKoro perHOHaG.Barzyk 1019
The structure of modern wind plants - a view of VESTAS A/S productsCTpyicrypa coBpeMeHHbix BeTposjieiopocTaHUHH - B3rnaA VESTAS A/SG.Barzyk, S.Kalisiak 1025
Conditions of concordance of longs lines with discrete loads with concentrated parametersYcjlOBHa COnpjDKeHHJi flnHHHblX J1HHHH H AHCKpeTHWX Harpy3OK C COCpeflOTOHeHHHMHnapaMexpaMHKP.Berzan 1031
775
Influencing factors on the transient induced currents and ground potentials rise along anenergized H.V. transmission lineOaicropw, BJiHflK>iiu4e Ha nepexoflHbie TOKH H noTeHUHajibi 3evuiH BAOJU BmuotaeMOH JIHHHH
pT.Bouthiba 1037Current commutation in paths of the ultra fast A.C. hybrid circuit breakerKoMMVTauHa TOKa B cBepx6bicTpofleHCTByioujHX rH6pnnHbix BbiionoHaTejiax nepeMeHHoro
TOKaJ.Czucha, J.Wotoszyn, M.Wotoszyn 1043
Simulation of changes in reliability of power transformers in power supply systems ofindustrial objects of seasonal operating characterCHMyjiaiUM Hafl&KHOCTH CHJ1OBWX TpaHC<j)OpMaTOpOB B CHCTCMaX nHTaHHa npOMHUIJieHHblX
o6-beKTOB c ce3OHHbiM peacHMOM pa6cm>i
A.Dzwonkowski 1049
Research in correct operation times and renewal times of transformers in industrial powerstationsHccjieflOBaHHa BpeMeH HcnpaBHoro COCTO8HH» H BoccTaHOBJieHwa TpaHC<j)opMaTopoB B
npoMbiuuieHHbix noflCTaHUHJix
A.Dzwonkowski 1055
Synchronization generator of an unconventional lighting systemFeHepa-rop CHHxpoHioyiomHx HMnyjibcoB HeTpaflHUHOHHOH cHcreMbi ynpaBJieHHa
Z.Frqckiewicz 1059
The adaptive nets, based on voltage invertersAnanrHBHbie ce™ Ha 6a3e HHBep-ropoB Hanpa>KeHHaY.M.Golembiovskfy 1063
Experimental research of computer-based method for synchronizing power generatorsHc&ne/iOBaHHH KOMnbiOTepHoro Me-ro^a cHHxpoHH3au.HH reHepaTopoB
AJ.Grono, J.P.Wlodarski 1069
Complex screens for managing systems of frequency convertersCjio)KHbie sKpaHbi fliw ynpaBnaiouiHx CHCTCM npeo6pa3OBaTejieH Macro™LH.Hairullin, F.Isntagilov, M.AMuhin 1075
Model of electrical network for GIS systemMoaanb ce™ FeorpacJiHHecKOH HH(J>opMau.HOHHOH CHCTCMWP.Helt 1079
Stochastic electromagnetic processes of the complex "Power system - compensated rectifier -random load"CTOxacTHHecKHe sjieicrpoMarHHTHbie npoueccw B KOMnjieKce nHTaiomaa ceTb -
KOMneHCHpoBaHHbifi BbinpaMHTeJib - cjiyHaHHaa Harpy3Ka
Y.I.Hohlov, D.N.Nikulin, E. V.Sherruble 1085
The prospects of electro-chemical generators employment in autonomous electric tractiontransmissionsFlepcneKTHBa Hcnonb30BaHna 3JieicrpoxHMHHecKHX reHepaTopoB B aBTOHOMHbix
A.I.Hozhaynov, G.E.Sereda, B.Rudakov, V. V.Nikitin 1089
Power electronics in north-west of Russia: the present state and trends of developmentCocrosHHe H nepcneKTHBbi pa3BHTH» CHJIOBOH sjieicrpoHHKH B ceBepo-3ana/iHOM perHOHePOCCHH
V.I.Hrisanov, I.M.Semenov, V.F.Hudyakov, V.CTomasov, V.L.Guzov, A.V.Demagin,NJLVologin 1095
776
The problems of application electromagnetic and electromechanical units for safety work limitsat IT type ship electric networkIIpo6j ieMbI npHMeHCHHSI 3JleKTpOMaTHHTHbIX H SJieKTpOMexaHHMeCKHX VCTpOHCTB flJIS
yBejuneHHa 3JieKTpo6e3onacHocTH B cyaoBwx CHJIOBWX cerax ™na ITJ.Hrynkiewicz 1101
Electromagnetic elements used in ship electric shock protecting systemFtpHMeHeHHe sjieicrpoMarHHTHbix ycrpoficTB B cyflOBofl CHCTeMe 3aiunTbi OT nopaxceHiu
pJ.Hrynkiewicz, R.Zeludziewicz 1107
Decentralised Kalman filter for integrated navigation system
P.Kaniewski, S.Konatowski 1113
The dynamic properties of certain non-stationary low-pass filters^HHaMHMeCKHe CBOHCTBa napaMeTpHMeCKHX HH3KOHaCTOTHbIX (J>WlbTpOB
R.Kaszyriski 1119
Design optimization and network integration considerations of gear-less permanent magnetwind turbinesFlpoeKTHaa onTHMH3auHH H o6m,He cxeMHbie pemeHHH ana 6e3pe,oyKTopHbix BeTpaHbixSHeproycTaHOBOK c nocToaHHbiMH MarHHTaMH
A.G.Kladas, M.P.Papadopoulos, J.A.Tegopoulos 1125
Demagnetization devicesPa3MarHHHHBaiomne ycTpoficTBaJ.Kolowrotkiewicz 1131
Performance of direct methanol fuell cellMeraHOJioBbiH ToruiHBbifl 3JieMenT ana npaMoro nojiyneHHa sJieicrposHeprHHE.Koziej, Z.Pottarzewski 1137
The peak power and electric energy consumption short-term forecasting using an artificialneural network in selected groups of electric power consumersYcKOpeHHoe npe.acKa3aHHe MaiccHMyMa MOUJHOCTH H noTpe6jieHHa sjieicrpHHecKOH sneprHHc Hcnojib3OBaHHeM HeftpoHHbix ceTeft B ceneicrHBHbix rpynnax 3JieKTponoTpe6nrejieHS.Kujszczyk, P.Piotrowski 1141
Optimisation of a directly driven, low-speed permanent-magnet wind generatorOirrHManiraauHa 6e3pe,ayKTopHoro HH3KOCKopocTHoro BeTporeHepaTopa c nocToaHHWMHMarHHTaMH
P.Lampola 1147
Analysis of temperature field distribution of electronic system in free and forced convectionAHanH3 pacnpe^ejieHHa TeMnepaTypHOro nona B sfleiapoHHOH CHereMe B ycjioBHaxecTecTBeHHoro H npHHyaHTcribHoro Tenjioo6M>KeHaA.Lukjaniuk, A.Jordan 1153
Methods of dividing investment capital in common plantsMero/i pa3flejieHH« KanHTanoBJiojKeHHH Ha nacTHbix npeflnpHaraax
W.Malewicz 1159
Cogenerate combined system with steam and gas turbogeneratorsKoM6HHHpoBaHbie reHepHpymHe cHcreMbi c napoBUMH H ra3OBUMH Typ6oreHepaTopaMHW.Malewicz, P.Szwed 1165
Conception of analysis of active power flow in power system under condition of deformedvoltage and currentKoHuenuHX aHanma noTOKa atrrHBHOH MOUIHOCTH B SHeprocHCTeMe npH HcicajKeHHbix (twpMaxHanpmceHiui H TOKaLMicek, R.Nowakowski 1171
777
Digital measurements in electrical power protections under current transformer saturationconditionLjH(t>poBbie H3Mepemw B cxeMax 3aiUHTbi SHeprocHCTeMbi n p n ycJiOBHH HacbimeHHa
TpaHC<J>opMaTopa TOKa
EMitkowski, KMusierowicz 1 ! 77
Transformer and transductor current transducersTpaHC(J)opMaTop H Hacbiinaroiinracji peaicrop npeo6pa3OBaTejieH TOKa
S.Moskowicz 1 1 8 3
Modeling a current density distribution inside nonmagnetic and ferromagnetic cylindrical loadsheated by electromagnetic inductionPacnpenejieHHe TeMnepaTypu H njioTHoc™ TOKa BHyTpn UHJiHHflpHHecKoro Tejia npHHHflyKUHOHHOM HarpeBeM. Namoune, A. H. Belbachir, M. Kamli 1187
Estimation of year peak loads of MV/LV transformer stations using evolutionary algorithms.OueHKa roflOBbix MaKCHMVMOB Harpy3OK MV/LV npeo6pa3OBaTejrbHbix CTaHimfi
C HCnOJIb3OBaHHeM 3B0JUOUHOHHMX ajirOpHTMOB
M.Parol, D.Baczyiiski 1193
Possibilities for applying the information system on electric energy distribution at powerengineeringFIpocTpaHCTBeHHaa HH<J>opMauHOHHaa cHCTeina ana noflnep)KKH 3Kcn.nyaTau.HH ceTeft HanpHMepe sjieiapoaHeprerHHecKHx cerefiM.Piwowarski 1199
Measurement of power system loop impedance in low voltage networkH3MepeHHe HinneaaHca nexriH KopoTKoro 3aMHKaHHa B ceTax HH3Koro Hanpa>KeHHaR.Roskosz 1203
The second generation of FACTS controllers to improving of power system dynamics stabilityBTopaa reHepauHa sjieMewroB <DAKTC ana HcnpaBJieHHa flHHaMHMecKott CTa6HJibHOCTH3JieKTpO3HepreTHHeCK0H CHCTeMbI
K-Szubert, G.Plenzler 1209
The influence of generator circuit-breaker on power plant availabilityBjinaHHe reHepaTopHoro BbuoiHDHaTejia Ha pa6orocnoco6HOCTb SHeproycTaHOBKHPSzwed 1215
Modeling of EM Field penetration in transient mode through a conductive layer or parallelconducting wiresMofle^HpoBaHHe npoHHKHOBeHHa sjieicrpoMarHHTHoro no.ua B nepexoflHbix pexcHMax nepe3
npoBOflauiHH c^ofi HJIH napannejibHO BKJiioHeHHbie npoBOflHHKHJ.Bel Hadj Tahar 1221
Control strategies of block-modular converter systemsCTpaTerHH yrtpaBJieHHa 6jioHHO-MO,nyjibHbiMH npeo6pa3OBaTenbHbiMH CHCTeMaMH
Y.B.Tomashevskiy 1227
The co-generation of heat and electric energy in rural farmsCoeflHHeHHoe npoH3BOflCTBO Tenjia H sneinpHHecKofl 3HeprHH B cenbCKHx xo3ancTBaxS. Turowski, R.Nowowiejski 1231
Autonomous supply sources with compounding harmonic control systemsABTOHOMHbie HCTOHHHKH nHTaHHH c cHCTeMOH rapMOHHHecKoro KOMnaynanpoBaHMa
GMUtlyakov 1237
Electrical machines with discrete-portioned windings3jiCKTpHHecKHe Maimnibi c AHCKpeTHO-pacnpeAeJieHHUMH o6MOTKaMH
OM Veselovskiy, D.L.Kaluzhskiy 1243
778
The influence of the type of current supply on the shapes of hysteresis loopsBjiHamie THna TOKa nHTaHHa Ha BH« neTJiH rncTepe3Hca/ . Wtodarska, Z. Wlodarski 1249
Combined controlled reactors-transformers for electric power engineeringCoBMeujeHHwe ynpaBjiaeMbie peaKTopbi-TpaHC<j>opMaTopbi ana sneinposHepreTHKHE.I.Zabudskiy 1253
Biological criteria for determination of magnetic field induction equivalent to electric fieldintensity near power transmission linesBHOJiorHMecKHfl KprnepHH ana onpeaeneHHa SKBHBafleHTHbix 3na4eHHH mmyKUHHMarHHTHoro nojia H HanpaaceHocTH sjieicrpHHecKoro nojia B6JIH3H JIHHHH sjieicrponepeaaHHM.Zericzak 1259
Section 5 Electromechatronics
CeKHHH 5 3jieKTpoMexaTpoiiHKa
p./CTp.
Strategy of the electromechatronic systems developmentCraTerua pa3BHTHa sjieicrpoMexaHOTpoHHbix cncTeMA.Afonin 1267
Optimisiation of regulation static and dynamic characteristics of electric drive with ventilmotor and sensibilith of controlOnTHMH3auHJi perynHpoBOMHbtx xapaKTepHCTHK sjieicrponpHBOfla c BeHTHJibHbiM aBHraTejieM
no nyBCTBHTejibHocTH KaHajiOB ynpaBJieHHa
A.Arakelyan, A. Afanasyev, G.Dmitriev 1273
Method of definition of limiting parametres of regulation for the drive of a n-mass systemMeroa onpeaeneHHa npeaejibHwx napaMeTpoB perynnpoBaHHa npHBoaoM n-MaccoBofiCHCTeMbI
I.Areflev O.Afanasyeva, A.Potapenko 1279
Dynamic performance evaluation of AC-DC converters supplying DC motors for unbalancedvoltagesOueHKa anHaMHHecKHx CBOHCTB AC-DC npeo6pa3OBaTejieH npH nHTaHHH aBHraTefinocToaHHoro TOKa HeycTOHMHBWM HanpaxceHHeMM.H.Belmimoun, A.Draou, M.A.Denai 1285
Model of a high-speed two-phase switched reluctance motorMoae^b BbicoKOCKopocTHoro asyx(})a3Horo BeHmnbHoro peaKTHBHoro aBHraTejiaB.Benedicic, D.MUjavec 1291
Influence of configuration of a thermoresistive converter upon the wave thermoanamometersystemBjiHHHHe KOH<j)HrypauHH TepMope3HCTHBHoro npeo6pa3OBaTe^a Ha pa3B«3Ky CHCTCMUBOJiHOBoro TepMoaHeMOMeTpaZ.Biernacki, M.Kurkowski, P.Rakus, T.Droidz 1297
Metrological aspects of the process of measuring the temperature of rotating parts by meansof a device with an optoelectronic sensorMerponorHHecKHe acneicru B npouecce H3Mepemui TeMnepaTypw BpauiaiouiHxca sjieMeHTOBnpH noMomw ycTpoiicTBa c onTosjieKTpoHHbiM ceHcopoMZ.Biernacki, T.Zloto 1303
779
Design of the multiple cage induction motor at given shape of the torque-speed characteristicripoein-HpoBaHHe MHoroKJieroHHoro acHHxpoHHoro aBHraTCJia npn 3aaaHHOH 4"°PMe
MOMeHTO-CKOpOCTHOfi XapaKTepHCTHKHM.Cistelecan, A.Campeanu, E.Demeter 1309
Properties of series resonant converter with sandwich-type piezoelectric ceramic transducerand FL controlCBoftcTBa nocneaoBaTeJibHoro pe30HaHCHoro npeo6pa3OBaTejia c nbe3O3JieKTpi«ecKHM
KepaMHHecKHM aaTHHKOM H FZ,-ynpaBJieHHeM
P.Fabijanski, R.lagoda 1315The comparative analysis of induction motor properties for scalar frequency control with themagnetic flux linkage stabilisation and stator current constraintsCpaBHHTenbHWH aHaJiH3 CBOHCTB acHHxpoHHoro aBHraTejia npH cicanapHOM nacTOTHOMynpaBJieHHH c o cTa6miH3auHeH noTOKOcueruieHHa H orpaHHneHHeM TOKa cTaTopa
BJ.Firago, L.Pawlaczyk 1321
Manner of controlling of three-winding brushless motorC n o c o 6 ynpaBJiefflM Tpexo6MOTOMHHM BeHTHUbHbiM aBHraTejieM
Z.Goryca, P.Bojarczak 1327
Modelling of transients of wind - driven - power - plant with permanent magnet synchronousgeneratorMoaeJinpoBaHHe nepexoaHbix npoueccoB B BeTposjieKTpHHecKoft ycTaHOBKec MarHHTosjieicrpHHecKHM CHHxpoHHbiM reHeparopoM
E.V.Kuleshov 1333
Using of the microprocessor for registration of distribution magnetic field curve in non-uniform air gap of two-speed shaded-pole induction motorHcnojib3OBaHHe MHicponpoueccopHoro ycTpoftcTBa an* perncTpauHH KPHBOH pacnpeaeJieHHaMarHHTHoro nojia B HepaBHOMepHOM BO3ayuiHOM 3a3ope aByxcKopocTHoro acHHxpoHHoroflBHraTena c SKpaHHpoBaHHWMH noraocaMHV.A.Lavrineneko 1339
Getting controlled monodisperced drops of liquids by using piezoelectric transformersFIojiyneHHe ynpaBJiaeMwx MOHoaHcnepcHbix icanejib acHaKocTefi c Hcnojib3OBaHHeMnbe303JieiopHMecKHx npeo6pa3OBaTejieHY.A.Levchenko, V.S.Nagorny 1343
Modeling of electromechanical transducers based on tuning forkMoaeJiHpoBaHHe sjiempoMexaHBHecKoro npeo6pa3OBaTena Ha ocHOBe KaMepTOHaG.A.Maryin, G.K.Smolin 1347
The generalized form of the Ampere law employment for electromechanotronic convertersdescription and researchFlpHMeHeHHe o6o6meHHofi 4>°PMbI 3aKOHa Avinepa ana H3VMeHHa H HccjieaoBarow3JieicrpoMexaHOTpoHHbix npeo6pa3OBaTenefiAG.Mikerov 1351
Determination of magnetic flux density in the air gap of reluctance motor using neuralnetworksOnpeaeJieHHe HHayKUHH MarHHTHoro nojra B BO3ayuiHOM 383ope peaKTHBHoro aBHraTejiac ncnoJTb3OBaHneM HcfipoHHbix cereHD.Miljavec, B.Benedicic 1357
On criterions of stable operation of frequency variable linear induction motorsO KpHTepHaX yCTOHMHBOH pa6OTbI HaCTOTHO-ynpaBJWeMblX JIHHefiHUX aCHHXpOHHblXABHraTejieftP.Osipov, N.Benalal 1363
780
The measuring system for analysis of imagesHaMepHTejibHaa CHcreMa aHajiroa o6i>eKTOB H3o6pa*eHHfiW.Owieczko 1367
Vibration damping in rotating two-mass-systems using piezoelectric actuatorsHcnojib3OBaHHe nbe3oaicryaTopoB ana aeMn(jmpoBaHHa BHSpaunfi BpaiuaiomeHcaaByXMaCCOBOH CHCTCMbl
F.Palis, U.Ladra 1371
The tank gun elevation stabiliser as a second-order multi-loop servomechanismMHoroKOHTypHbifl cepBOMexaHH3M BToporo nopaaKa ana CTa6wiH3auHH opyana TaHKaKM.Papliiiski, Z.Sobczyk 1377
Mathematical model in the phase axis of the induction motor electric drives with DTCMaTeMaTHHecKaa Moaejib B $a3Hbix KOopaHHaTax acHHxpoHHoro sneinponpHBoaacDTCE.G.Plachtyna, R.Borowski, K.Jagiela, A.O.loziriski 1383
Circuit and field simulation of permanent magnet brushless DC motorMoaennpoBaHHe BeHmnbHoro aBHraTejia c nocToaHHWMH MarHHTaMH MeroaoM uenefiH no^eflM.Ronkowski, M.Michna, R.Szczesny, A. WUk 1389
Application of electrohydraulic analogy for modelling and simulation of hydraulic systemsHcnojib3OBaHHe sjieKTporHapaBJiHHecKofi aHajiorHH ana MoaeJiHpoBaHHa H CHMynauuH
Z.Zarzycki „ 1395
781
Last minute papers
nojiyneHHbie B nocjieamoK) MHHyTy
p./CTp.
Transmission of hybrid electric vehiclesTpaHCMHCCHH rH6pHaHoro 3JieicrpoMo6HJiaD.I.Guranov, A.K.Makarov, S.A.Korczak, Nguyen Kuang They, Liu Siao Kan 1401
New class of linear induction motor drive for transportation and technological equipmentsHoBbifl iciiacc jiHHeHHoro saeicrponpHBoaa ana TpaHcnopTHo-TexHOjiorHHecKoroo6opyaoBaHHaBJ.Petlenko 1405
Maximum power point tracker for solar carsOm-HMafoep KOM6HHHpoBaHHOH 3HeproycTaHOBKH cojiHueMo6HjiaBJ.Petlenko, D.I.Guranov, Nguyen Kuang They 1411
Energy conversion processes in solar carFlpoueccbi 3Hepronpeo6pa30BaHna B ropoacKOM cojiHueMoGnjieNguien Kuang They, Do VanZung 1417
Structures peculiarity of armature windings with fractional number of slots per pole and phaseand MMF analysis for A.C. machinesOco6eHHocTH CTpyicrypbi MHoro(j>a3HOH O6MOTKH C apo6HbiM q MauiHH nepeMeHHoro Toxa HaHajiH3 ee MflCl.Z.Boguslavskiy, H.Kuss 1421
782