90
900
9000
9000
øø14000
11750
17500
øø14000
888500
V
580044
00
ø1400
9290 4100
160010400
9000
ø1 4
BB
V
00
• LIGHTWEIGHT• NO CONDENSATION• ATTRACTIVE PRICE
• NOISELESS VENTILATION• FAST AND EASY INSTALLATION
• DRAFT-FREE AIR DISTRIBUTION• WASHABLE AND HYGIENIC
• WIDE COLOR SELECTION• LONG SERVICE LIFE
• CUSTOM-MADE
FabricAir® Dispersion SystemsSALES CATALOG
49ENG
2
No extra grilles or diffusers are
necessary. The fabric system
functions both as a duct
system and as an air
dispersion system.
No damper is necessary.
A fabric system does not
require balancing.
No extra
noise
reduction
is needed
(except
perhaps
reduction
of fan
noise).
Noiseless is
the standard.
No inconvenient
alterations or assembly
straight from the factory, is
assembled with zip fasteners and
is ready for installation as soon as
it arrives.
No extra insulation is
necessary. A fabric system
is condensation free.
Fabric Systems – Air Dispersion – All Inclusive
Painting is not
necessary. The
fabrics are
dyed.
INTRODUCTION
3
TRANSPORTATIONMetal ducts take up a lot of space. This is
Fabric systems are rolled up and
transported by courier or a freight
company. Savings are 20% to 70%.
DIFFERENCE IN COSTS
A fabric system
A conventional
metal system
MATERIALSThe price of metal is unstable and has
become very high over the years.
The price of fabric is stable and has not
changed substantially over the years.
Savings are 10% to 40%.
INSTALLATIONAssembling metal ducts is time-
consuming. Working with fabric
systems is easy and simple.
Savings are 20% to 90%.
INTRODUCTION
4
A Versatile System Design
The possibilities for creating a
versatile system design are at the
very least the same as conventional
ducts. In most cases the versatility
is greater.
INTRODUCTION
Elbows – made with the exact angle
desired. There are no restrictions as
to direction or dimensions.
Reductions and transitions – All transitions
and reductions are made in fabric. Based on
the suspension system chosen, the optimum
transitions and reductions are selected.
Outlet branch – transition from
a main duct to a side duct
through an outlet branch.
5
39
8
7
1211 1
5
2
4
10
6
39
8
7
1211 1
5
2
4
100
6
Download complete
component drawings at
www.fabricair.com
- dwf (AutoCad 3D)
- dwg (AutoCad 2D)
- pdf (Acrobat 3D)
- pdf (Acrobat 2D)
The fabric ducts are adapted to
variable.
INTRODUCTION
Flow models – The air
is distributed through
position. The position is given by using
a dial.
Flowstraightener (FLS) is used to
rectify or regulate the air in a duct. A
FabricAir® system is usually designed in
a way that makes cones unnecessary.
are round and half round ducts, which
are supplied as standard solutions.
Other solutions require custom design at
FabricAir®.
6
The air is evenly distributed throughout
the length of the fabric system. The
distribution of air can be controlled
with great precision and can be easily
optimized.
Increased Comfort for the Occupants
A conventional duct
with grills or diffusers
distributes the air
at certain points,
resulting in uneven air
distribution.
NO NOISEThe noise from the fabric system is
very limited. It is possible to achieve
low levels of noise with conventional
metal ducts but they usually require
special noise reduction. In the fabric
system the only thing needed is the
BROAD RANGE OF COLORSThe fabric systems are
supplied in a broad range
of standard colors – at
no added cost. Several
fabrics can also be
supplied in special colors.
NO DRAFTSAll of the fabric systems from
FabricAir® are dimensioned to
make it as comfortable as possible
for the individual employee. As a
consequence, it is only natural that the
fabric systems do not cause discomfort
due to drafts.
INTRODUCTION
7
FabricAirFabricAir FabricAirFabricAir FabricAirFabricAir FabricAirFabricAir FabricAirFabricAir FabricAirFabricAir FabricAirFabricAir FabricAirFabricAir
Efficient Distribution of Air
®
®
ADJUSTED THROWWhen a fabric system is dimensioned, the
products ranges from low impulse solutions to
solutions with a long throw.
NO CONDENSATIONMetal ducts need insulation to avoid
condensation problems. This is not the
case with fabric ducts. The air permeable
material prevents condensation.
INTRODUCTION
8
Niels Falk
Issued on:Validity date:
Registration Number:
2012.11.202015.12.06010833
IQNet Partners*:AENOR Spain France Belgium ANCE Mexico APCER Portugal CCC Cyprus
CISQ Italy CQC China CQM China CQS Czech Republic Croatia Germany DS Denmark ELOT Greece FCAV Brazil FONDONORMA Venezuela ICONTEC Colombia Tunisia
Finland IRAM Argentina JQA Japan KFQ Korea MSZT Hungary Norway NSAI Ireland PCBC Poland Austria RR Russia SII Israel SIQ Slovenia Malaysia SQS Switzerland
SRAC Romania Russia TSE Turkey YUQS Serbia
Michael DrechselPresident of IQNet
Managing director
Side 1 af 2
CERTIFICATEIQNet and
Partnering with FabricAir®
FabricAir® as Partner®
Consultancy and Documentation®
The entire FabricAir® group has an ISO 9001
INTRODUCTION
FabricAir® Customer Service
Our sales companies all have
a competent customer service
function, which is ready at the
phones to answer questions,
prepare quotes and handle orders.
9
FabricAir® Installation Service
®
All fabrics used in our production undergo
a strict quality and environmental
control. Most of our fabrics comply with
the Oeko-Tex 100 standard.
For more than 10 years FabricAir® has
been able to offer the servicing of
the fabric systems at our own laundry
facility.
The fabric systems are dimensioned
and constructed based on online 3D
FabricAir® Supervisor Service®
®
FabricAir® Service Concept®
®
INTRODUCTION
15
Hygienic Advantages through Washing and Bacteria Control
No Condensation
Anti-microbial Properties
®
®
Cleaning
If a production must run round the clock while the ducts
are washed a spare set of ducts is a good solution to
avoid unnecessary shutdowns.
Service
®
®
EASY CLEANING
form of bacteria control.
GALLERY
Equalizing rooms, slicing rooms, warehouses,
food terminals, cold working areas
16
FEW TOOLSDetailed instructions for installing the
systems are given in the instructions
manual supplied. Only a few tools are
needed.
The duct sections are zipped together.
The zipper is hidden behind a sewn
FAST INSTALLATIONThe suspension system is installed
from a ladder or lift. No matter if a
rail or cable solution is chosen, the
installation is quick and simple.
The info label found on each duct
section shows where the section
must be placed in the duct system.
Installation
Practical Advantages Make the Installation Fast
LOW WEIGHTA FabricAir® fabric system does not put
a strain on ceilings or roof constructions
because we always use low-weight
fabrics. In spite of the weight, the
fabrics are very strong and durable.
17
All-in-One is supplied in the most
cost-effective version installed on
cables, as seen in the illustration.
Classic
Regular systems with single suspension are
turned off. This is not the case with All-in-
One systems.
All-in-One
Only a slight change of the circular shape
occurs with All-in-One when the air is
turned off.
®
All-in-One on an H-rail. Ducts on
H-rails are quickly installed or taken
down for washing.
All-in-One for Better Looking Ducts
All-in-One ensures that the ducts are
always stretched out, even when there is
no air in the system. Suspension type 8,
All-in-One, is shown here.
With All-in-One, support hoops
The hoops are removable and are
removed prior to washing.
With air With airWithout air
Without air
INSTALLATION
18
TYPE 2, DOUBLE CABLE TYPE 13, DOUBLE H-RAIL
TYPE 1, SINGLE CABLE
TYPE 6, DOUBLE H-RAIL
TYPE 11, D-SHAPED T-RAIL
TYPE 8, SINGLE H-RAIL
TYPE 3, SINGLE T-RAIL TYPE 12, D-SHAPED T-RAIL
TYPE 5, SINGLE H-RAIL
Suspension Types
INSTALLATION
All-in-One All-in-One
Classic Classic
All-in-One
Classic
19
Permeable Fabric Non-permeable Fabric
Fabrics
SYMBOLS USED FOR FABRIC PROPERTIESWarranty. A high-quality product with a 10 year warranty. Some fabrics have 10, 5 or 1 year warranty programs. The warranty does not change during this period.
Washable. The fabric can be washed in a washing machine, thereby maintaining a good and high level of hygiene.
Low permeability tolerance. Low tolerance ensures the technical performance.
Dimensionally stable. Shrinkage less than 0.5%, ensuring that the fabric keeps its shape when washing
All-in-One. Optimal type of mounting, which keeps the duct round – even without air. The solution furthermore reduces unwanted wear during system start-up.
Antistatic. The material does not conduct static electricity.
fabric according to the Oeko-Tex 100 standard as being free of substances, which are harmful for people and the environment.
Permeable fabric
Non-permeable fabric
Antimicrobial treatment. Repels and kills bacteria and effectively prevents microorganisms from growing.
Fire retardant. Approved according to
fabric.
FabricAir® produced more than
1,000,000 meter (3,000,000 ft) of
fabric-based ducts in 2013.
20
FABRICAIR® TREVIRA BASIC
FABRICAIR® TREVIRA CS 100
FABRICAIR® TREVIRA CS 150
FABRICA
FABRICA
FABRICA
FabricAir® Trevira
About FabricAir® Trevira®
®
®
®
Certificates Tre
vir
a B
asi
c
Tre
vir
a C
S 1
00
Tre
vir
a C
S 1
50
EN 13501-1 B-s1,d0 B-s1,d0
PerformanceCertificates
FABRICS
2121
Standard Colors
for Accessories
®10011000
®
®
Standard Colors for the Fabric
®
SAFE MOUNTING Fabric ducts
connected to
sheet metal systems
are secured using
a pinch-down
duct belt.
OriFlow™The air is distri buted through large
SonicFlow™The air is distributed through lengthwise rows of small
NozzFlow™The air is distributed through venturi shaped plastic nozzles with exellent discharge
PerfoFlow™ The air is distributed through small
MicroFlow™ The air is distributed through micro-perforations.
JetFlow™ FabricAir®’s Jet Flow™ with built-in Jets provide exceptionally long throws for large areas.
ALL-IN-ONEOptionally,
FabricAir® Trevira
can be supplied
with All-in-One
support hoops
which keep
the duct open
permanently.
ZIP FASTENERThe sections are
assembled with
heavy-duty
industrial zip
fasteners,
discreetly
hidden under an
extra seam.
TAG NUMBEREach duct section is
labelled with a tag number,
which indicates the
order of assembly.
Furthermore, it contains
an ID number, which
makes the tracking easier.
FabFlow™The air is distributed through the entire surface of the fabric.
FABRICS
22
FabricAir® Combi
FABRICAIR® COMBI 65
FABRICAIR® COMBI 60
FABRICAIR® COMBI 70
FABRICAIR® COMBI 80
FABRICAIR® COMBI 85
FABRICAIR® COMBI 90
FA AABRBRBBRBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBRBBRBBBBBBRRBBBRRRRRRRBBRRRRBBBBRRRICA
FAABRICAABRBBBBBBBBBBBBBBBBBBBBBBBBB ICA
FA AABRBRBRBBRBBBBBBBBBBBBBBBBBBBBBBBBBBRBBBBBBRBBBBBBRBBRBBBBBRRBBBRRRRRBBBBBRRRICAIR COMB
IR COMBB
CO
CO
FABRICAIR® COMBI 20
FABRICAIR® COMBI 30
IR COMB
FA AABRBRBRBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBRBBRBBBBBRRBBBRRRRICA
About FabricAir® Combi®
®
®
®
®Certificates C
om
bi
20
Com
bi
30
Com
bi
60
Com
bi
65
Com
bi
70
Com
bi
80
Com
bi
85
Com
bi
90
EN 13501-1 B-s1,d0 B-s1,d0 B-s1,d0 B-s1,d0 B-s1,d0 B-s1,d0
GOST
PerformanceCertificates
FABRICS
2323
®
Tan
3008
Green
3007
Light Gray
3006
Red
3005
Black
3004
Dark Gray
3003
Orange
3002
Blue
3001
White
3000
Standard Colors
for Accessories
®
®
Standard Fabric Colors
®
SAFE MOUNTING Fabric ducts
connected to
sheet metal systems
are secured using
a pinch-down
duct belt.
ALL-IN-ONEOptionally,
FabricAir® Trevira
can be supplied
with All-in-One
support hoops
which keep
the duct open
permanently.
ZIP FASTENERThe sections are
assembled with
heavy-duty
industrial zip
fasteners,
discreetly
hidden under an
extra seam.
TAG NUMBEREach duct section is
labelled with a tag number,
which indicates the
order of assembly.
Furthermore, it contains
an ID number, which
makes the tracking easier.
OriFlow™The air is distri buted through large
SonicFlow™The air is distributed through lengthwise rows of small
NozzFlow™The air is distributed through venturi shaped plastic nozzles with exellent discharge
PerfoFlow™ The air is distributed through small
MicroFlow™ The air is distributed through micro-perforations.
FabFlow™The air is distributed through the entire surface of the fabric.
JetFlow™ FabricAir®’s Jet Flow™ with built-in Jets provide exceptionally long throws forlarge areas.
FABRICS
24
FabricAir® Lite
FABRICAIR® LITE 10
FABRICAIR® LITE 5
FABRICAIR® LITE 15
FABRICAIR® LITE 20
FA AABRBBRBBRBBBBBRBBBBBBBBBBBBBRBBBBBBBBBBBBRBBBBBRBRBBBBBBBBBRBBBBBBRRRRRBBRBBRRICA
FA AABRBBRBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBRBRRBBBBBRRRRRRBBRRRRICA
FA AABRBBRBBRBBBBBBBBBBBRBRBBBBBBBBBBBBBBBBBBBBBBBBBBBBBRBBBBBBRBBRBBRBRRRBBBBBRRRBBRRRRRICA
FA AABRBBRBBRBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBRBRRBBBBBRRRRRRBBRRRRRRRICA
AIR LITE 1AA
AIR LITE 2AA
151
0
About FabricAir® Lite®
®
Certificates Fab
ricA
ir® L
ite 5
Fab
ricA
ir® L
ite 1
0
Fab
ricA
ir® L
ite 1
5
Fab
ricA
ir® L
ite 2
0
EN 13501-1 B-s1,d0 B-s1,d0 B-s1,d0
FABRICS
252525
Standard Colours
for Accessories
ZIP FASTENERThe sections are assembled
using heavy-duty industrial
zips discreetly hidden under
an extra seam.
TAG NUMBEREach duct section is labelled with a tag
number which indicates the order of
assembly. It also contains an ID number,
which makes the tracking easier.
SAFE MOUNTING Fabric ducts connected to sheet
metal systems are secured using a
pinch-down duct belt.
Standard Fabric Colours
®
®
Black
7504
Grey
7503
Blue
7501
White
7500
®
®
OriFlow™The air is distri buted through large
MicroFlow™ The air is distributed through micro-perforations.
SonicFlow™The air is distributed through lengthwise rows
PerfoFlow™ The air is distributed through small
FABRICS
26
FabricAir® Poly
FabricAir® Glass 220
Certificates Poly
®
®
®
FABRICS
Certificates Gla
ss 2
20
EN 13501-1 A2-s1, d0
NFP 92-507:2004 MO
GOST
27
Standard Colours
for Accessories
Standard Fabric Colors
®
®
®
ZIP FASTENERThe sections are assembled
using heavy-duty industrial
zips discreetly hidden under
an extra seam.
TAG NUMBEREach duct section is labelled with
a tag number which indicates the
order of assembly. It also contains
an ID number, which makes the
tracking easier.
OriFlow™The air is distri buted through large
MicroFlow™ The air is distributed through micro-perforations.
OriFlow™The air is distri buted through large
SonicFlow™The air is distributed through lengthwise rows of small
NozzFlow™The air is distributed through venturi shaped plastic nozzles with exellent discharge
PerfoFlow™ The air is distributed through small
®
FabricAir® Glass 220
FabricAir® Poly
FABRICS
28
FabFlow™
MicroFlow™™
™
In FabFlow™, the air exits the duct
through the permeable fabric surface.
The air is driven by thermodynamic
forces preventing drafts in the occupied
zone, resulting in a high level of comfort.
NC levelDesign pressure:
NC levelDesign pressure:
Flow Models
Fabrics suitability
suitable for these fabrics:
Fabrics suitability
suitable for these fabrics:
FLOW MODELS
Micro-perforations 0,2–0,6 mm[0.008”–0.024”] diameter
Maximum 300 mm [11.81”]
0.24 0.32 0.40 0.48 0.56 0.64 0.72 0.80
Fabric: 60 80 100 120 140 160 180 200
FabricAir® Trevira Basic 15 15 15 20 20 25 25 25
FabricAir® Trevira CS 100 15 15 15 20 20 25 25 25
FabricAir® Trevira CS 150 15 15 15 20 20 25 25 25
FabricAir® Combi 20 15 15 15 20 20 25 25 25
FabricAir® Combi 30* - - - - - - - - -FabricAir® Combi 60 15 15 15 20 20 25 25 25
FabricAir® Combi 65* - - - - - - - - -
FabricAir® Combi 70 15 15 15 20 20 25 25 25
FabricAir® Combi 80 15 15 15 20 20 25 25 25
FabricAir® Combi 85* - - - - - - - - -
FabricAir® Combi 90* - - - - - - - - -
FabricAir® Lite 5* - - - - - - - - -
FabricAir® Lite 10* - - - - - - - - -
FabricAir® Lite 15* - - - - - - - - -
FabricAir® Lite 20* - - - - - - - - -
FabricAir® Glass 220* - - - - - - - - -
FabricAir® Poly* - - - - - - - - -
* = Non permeable
Permeable
0 (surface velocity below 0,5 m/s or [98 fpm])
Characteristics
model are:
Characteristics
model are:
0.24 0.32 0.40 0.48 0.56 0.64 0.72 0.80
Fabric: 60 80 100 120 140 160 180 200
FabricAir® Trevira Basic 20 25 25 30 30 35 35 40
FabricAir® Trevira CS 100 20 25 25 30 30 35 35 40
FabricAir® Trevira CS 150 20 25 25 30 30 35 35 40
FabricAir® Combi 20 20 25 25 30 30 35 35 40
FabricAir® Combi 30* 20 25 25 30 30 35 35 40
FabricAir® Combi 60 20 25 25 30 30 35 35 40
FabricAir® Combi 65* 20 25 25 30 30 35 35 40
FabricAir® Combi 70 20 25 25 30 30 35 35 40
FabricAir® Combi 80 20 25 25 30 30 35 35 40
FabricAir® Combi 85* 20 25 25 30 30 35 35 40
FabricAir® Combi 90* 20 25 25 30 30 35 35 40
FabricAir® Lite 5* 20 25 25 30 30 35 35 40
FabricAir® Lite 10* 20 25 25 30 30 35 35 40
FabricAir® Lite 15* 20 25 25 30 30 35 35 40
FabricAir® Lite 20* 20 25 25 30 30 35 35 40
FabricAir® Glass 220* 20 25 25 30 30 35 35 40
FabricAir® Poly* - - - - - - - - -
* = Non permeable
29
PerfoFlow™
0.24 0.32 0.40 0.48 0.56 0.64 0.72 0.80
Fabric: 60 80 100 120 140 160 180 200
FabricAir® Trevira Basic 25 30 30 30 35 35 40 40
FabricAir® Trevira CS 100 25 30 30 30 35 35 40 40
FabricAir® Trevira CS 150 25 30 30 30 35 35 40 40
FabricAir® Combi 20 25 30 30 30 35 35 40 40
FabricAir® Combi 30* 25 30 30 30 35 35 40 40
FabricAir® Combi 60 25 30 30 30 35 35 40 40
FabricAir® Combi 65* 25 30 30 30 35 35 40 40
FabricAir® Combi 70 25 30 30 30 35 35 40 40
FabricAir® Combi 80 25 30 30 30 35 35 40 40
FabricAir® Combi 85* 25 30 30 30 35 35 40 40
FabricAir® Combi 90* 25 30 30 30 35 35 40 40
FabricAir® Lite 5* 25 30 30 30 35 35 40 40
FabricAir® Lite 10* 25 30 30 30 35 35 40 40
FabricAir® Lite 15* 25 30 30 30 35 35 40 40
FabricAir® Lite 20* 25 30 30 30 35 35 40 40
FabricAir® Glass 220* 25 30 30 30 35 35 40 40
FabricAir® Poly* - - - - - - - - -
* = Non permeable
NC levelDesign pressure:
Flow Model Principles
Fabrics suitability
suitable for these fabrics:
FLOW MODELS
Elements affecting air flow
by many factors. Occasionally these
patterns.
In this context, it is important to
consider:
• the geometry of the room
• the placement of duct accessories:
• exhaust placement
• heat-source placement
• permeability of the fabric
With PerfoFlow™ the air exits the
duct via laser cut perforations, along
the circumference of the duct. The
perforations can cover between 90°
and 360° of the duct’s circumference.
The size of the near zone depends on
the static pressure inside the duct, the
percent of the circumference that is
perforated, the size and spacing of the
perforations.
Perforations 3,0-14,0 mm [0.12”-0.55”] diameter
up to 6,400 mm [21’]
Characteristics
model are:
30
SonicFlow™
OriFlow™
NC levelDesign pressure:
where the air exits the duct via rows of
laser cut perforations. Multiple rows of
with each row covering a maximum of
30° of the circumference. The throw
depends on the static pressure inside
the duct, the size, and spacing of the
perforations.
Fabrics suitability
suitable for these fabrics:
NC levelDesign pressure:
where the air exits the duct via rows
The throw depends on the static
pressure inside the duct, the size,
Fabrics suitability
suitable for these fabrics:
FLOW MODELS
0.24 0.32 0.40 0.48 0.56 0.64 0.72 0.80
Fabric: 60 80 100 120 140 160 180 200
FabricAir® Trevira Basic 25 30 30 30 35 35 40 40FabricAir® Trevira CS 100 25 30 30 30 35 35 40 40FabricAir® Trevira CS 150 25 30 30 30 35 35 40 40FabricAir® Combi 20 25 30 30 30 35 35 40 40FabricAir® Combi 30* 25 30 30 30 35 35 40 40FabricAir® Combi 60 25 30 30 30 35 35 40 40FabricAir® Combi 65* 25 30 30 30 35 35 40 40FabricAir® Combi 70 25 30 30 30 35 35 40 40FabricAir® Combi 80 25 30 30 30 35 35 40 40FabricAir® Combi 85* 25 30 30 30 35 35 40 40FabricAir® Combi 90* 25 30 30 30 35 35 40 40FabricAir® Lite 5* 25 30 30 30 35 35 40 40FabricAir® Lite 10* 25 30 30 30 35 35 40 40FabricAir® Lite 15* 25 30 30 30 35 35 40 40FabricAir® Lite 20* 25 30 30 30 35 35 40 40FabricAir® Glass 220* 25 30 30 30 35 35 40 40FabricAir® Poly* - - - - - - - -
* = Non permeable
0.24 0.32 0.40 0.48 0.56 0.64 0.72 0.80
Fabric: 60 80 100 120 140 160 180 200
FabricAir® Trevira Basic 20 25 25 25 30 30 35 35FabricAir® Trevira CS 100 20 25 25 25 30 30 35 35FabricAir® Trevira CS 150 20 25 25 25 30 30 35 35FabricAir® Combi 20 20 25 25 25 30 30 35 35FabricAir® Combi 30* 20 25 25 25 30 30 35 35FabricAir® Combi 60 20 25 25 25 30 30 35 35FabricAir® Combi 65* 20 25 25 25 30 30 35 35FabricAir® Combi 70 20 25 25 25 30 30 35 35FabricAir® Combi 80 20 25 25 25 30 30 35 35FabricAir® Combi 85* 20 25 25 25 30 30 35 35FabricAir® Combi 90* 20 25 25 25 30 30 35 35FabricAir® Lite 5* 20 25 25 25 30 30 35 35FabricAir® Lite 10* 20 25 25 25 30 30 35 35FabricAir® Lite 15* 20 25 25 25 30 30 35 35FabricAir® Lite 20* 20 25 25 25 30 30 35 35FabricAir® Glass 220* 20 25 25 25 30 30 35 35FabricAir® Poly* 20 25 25 25 30 30 35 35
* = Non permeable
Perforations 3,0–14,0 mm[0.12”–0.55”] diameter
7,0 to 13,0 m/s [1,378 to 2,559 fpm]
Medium–directional
Characteristics
model are:
[0.56”–4.92”] diameter
7,0 to 18,0 m/s [1,378 to 3,543 fpm]
High–directional
Characteristics
model are:
31
NozzFlow™
JetFlow™
NC levelDesign pressure:
NC levelDesign pressure:
The nozzles can be placed anywhere
needed on the duct surface so that
conditioned air easily can be directed
to where it is needed.
The jets can be placed anywhere
needed on the duct surface so that
conditioned air easily can be directed
to where it is needed.
NozzFlow™ is used in applications
almost at unity, due to the shape of the
nozzle. This results in higher discharge
velocities, than an equivalently sized
throws.
JetFlow™ is capable of generating
exceptionally long throws through
the use of conical jets, in varying
diameters. The jets have a very high
conical shape of the jet. This results
in higher discharge velocities, than an
Fabrics suitability
suitable for these fabrics:
Fabrics suitability
suitable for these fabrics:
FLOW MODELS
Nozzles 18,0 mm [0.70”] diameter
7,0 to 20,0 m/s [1,378 to 3,937 fpm]
High–directional
Characteristics
model are:
Jets 50 to 250 mm [1.97” to 9.84”] diameter
10,0 to 20,0 m/s [1,969 to 3,937 fpm]
High–directional
Characteristics
model are:
0.24 0.32 0.40 0.48 0.56 0.64 0.72 0.80
Fabric: 60 80 100 120 140 160 180 200
FabricAir® Trevira Basic 20 20 25 25 30 30 35 35FabricAir® Trevira CS 100 20 20 25 25 30 30 35 35FabricAir® Trevira CS 150 20 20 25 25 30 30 35 35FabricAir® Combi 20 20 20 25 25 30 30 35 35FabricAir® Combi 30* 20 25 25 30 30 30 35 35FabricAir® Combi 60 20 20 25 25 30 30 35 35FabricAir® Combi 65* 20 25 25 30 30 30 35 35FabricAir® Combi 70 20 20 25 25 30 30 35 35FabricAir® Combi 80 20 20 25 25 30 30 35 35FabricAir® Combi 85* 20 25 25 30 30 30 35 35FabricAir® Combi 90* 20 25 25 30 30 30 35 35FabricAir® Lite 5* - - - - - - - - -
FabricAir® Lite 10* - - - - - - - - -
FabricAir® Lite 15* - - - - - - - - -
FabricAir® Lite 20* - - - - - - - - -
FabricAir® Glass 220* 20 20 25 25 30 30 35 35FabricAir® Poly* - - - - - - - - -* = Non permeable
0.24 0.32 0.40 0.48 0.56 0.64 0.72 0.80
Fabric: 60 80 100 120 140 160 180 200
FabricAir® Trevira Basic 20 20 25 25 30 30 35 35FabricAir® Trevira CS 100 20 20 25 25 30 30 35 35FabricAir® Trevira CS 150 20 20 25 25 30 30 35 35FabricAir® Combi 20 20 20 25 25 30 30 35 35FabricAir® Combi 30* 20 25 25 30 30 30 35 35FabricAir® Combi 60 20 20 25 25 30 30 35 35FabricAir® Combi 65* 20 25 25 30 30 30 35 35FabricAir® Combi 70 20 20 25 25 30 30 35 35FabricAir® Combi 80 20 20 25 25 30 30 35 35FabricAir® Combi 85* 20 25 25 30 30 30 35 35FabricAir® Combi 90* 20 25 25 30 30 30 35 35FabricAir® Lite 5* - - - - - - - - -FabricAir® Lite 10* - - - - - - - - -FabricAir® Lite 15* - - - - - - - - -FabricAir® Lite 20* - - - - - - - - -FabricAir® Glass 220* - - - - - - - - -FabricAir® Poly* - - - - - - - - -* = Non permeable
90 90 900
øø14000
000
900
øø14000
Køleanlæg
PORT
98 cm.98 cm.
000000000
000000000
0000000000
[email protected] www.fabricair.com
5800
4400
ø1400
900
92904100
160010400
9000
ø1300
4900
BB
®
VISIT WWW.FABRICAIR.COM TO:• DOWNLOAD DRAWINGS • SEE ANIMATED INSTALLATION • DOWNLOAD PICTURES • FIND REPRESENTATIVES• DOWNLOAD SPECS AND DETAILS
®
FabricAir® Dispersion Systems