Page 1: Vacuum Pressures at IR

Vacuum Pressures at IR

Contents

Y.SuetsuguKEKB Vac. Group

1. Outline of Vacuum System at IR2. Behavior of Pressures 3. Remedies for Heating of Vacuum Components

Page 2: Vacuum Pressures at IR

Vacuum System at IR• Here IR (Interaction region) means the straight section in

±~100 m from IP (Interaction Point), especially upstream side of each ring.

• Material of beam duct: OFC (Oxygen Free Copper) for most part (both rings). Aluminum alloy for complicated chamber just near to IP.

[OFC] [Aluminum Alloy]

Page 3: Vacuum Pressures at IR

Vacuum System at IR• Vacuum pump: Main pump = NEG (st707) : almost every

1 m (0.2 m3/s), Auxiliary pump = Ion pumps : almost every 10 m (0.2 m3/s). In average, about 0.7 m3/s/m just after an activation of NEG.

NEG module (just near to IP)

NEG cartridge

(arc section)

Page 4: Vacuum Pressures at IR

Vacuum System at IR• Vacuum gauge = CCG (Cold Cathode Gauge) just above ion pumps

(every ~10 m). A small dipole magnet (permanent magnet) is attached at the neck of gauge port to eliminate photoelectron effect.

CCG

~100 G

Without Manget

Page 5: Vacuum Pressures at IR

Vacuum System at IR• Location of Gauges and Pumps near to IP

IP

LER HER

(D02_H24) D02_H23AD01_H01AD01_H02A

D02_H23D01_H02

[Inside of BELLE Solenoid]

Integrated NEG

Integrated NEG

0 5 m 10 m

Page 6: Vacuum Pressures at IR

Vacuum System at IR• HER Upstream Side (straight section, ~100 m)• Straight : No bending magnet• Gauges: every ~10 m

IP

D01_H01AD01_H02AD01_H03

D01_H8

D01_H04

D01_H09

D01_H05

D01_H10

D01_H06D01_H7

D01_H11

HER

GV

GV

GVBS

Page 7: Vacuum Pressures at IR

Vacuum System at IR• LER Upstream Side (straight section, ~100 m)• Local correction region: 13 bending magnets• Gauges: every ~10 m

LER

D02_H23A D02_L24 D02_L23 D02_L22 D02_L21

D02_L20 D02_L19 D02_L18

D02_L17 D02_L16

IP

GV

BS

GV

GV

Page 8: Vacuum Pressures at IR

Behavior of Pressure• HER_1

IP

D01_H8 D01_H06D01_H7

2x10-7 Pa

00 1.4 A

Heat Source = Gate Valve

Three daysincluding several beam Injections.

P

Ib

Big BG Source

D01_H01AD01_H02AD01_H03D01_H04

Page 9: Vacuum Pressures at IR

Behavior of Pressure• HER_2

Three daysincluding several beam injections.

D01_H8

D01_H09D01_H10

D01_H06

D01_H7

D01_H11Heat Source = HOM Absorber, Taper

Heat Source = Stopper (~ Gate Valve)

Gate Valve

Gate Valve

Page 10: Vacuum Pressures at IR

Behavior of Pressure• LER_1

Three daysincluding several beam aborts.

D02_H23A D02_L24 D02_L23 D02_L22D02_L21

D02_L20 D02_L19 D02_L18

IP

Heat Source = Gate Valve

? (NEG?)

Heating +NEG? Multipactoring?

3x10-7 Pa

00 2.0 A

P

Ib

Page 11: Vacuum Pressures at IR

Behavior of Pressure• LER_2

Three daysincluding several beam aborts.

D02_L20 D02_L19 D02_L18

D02_L17 D02_L16 D02_L15Heat Source = Stopper

Heat Source = Taper

? (NEG?)

Gate Valve

Gate Valve

Page 12: Vacuum Pressures at IR

Present Status

• The pressures near to IP is <1x10-7 Pa for HER and ~2x10-7 Pa for LER at the maximum operation current.

• The pressures at upstream side of IP (IR) is almost less than 1x10-7 Pa, but affected by the heating of components, such as gate valves, stoppers, HOM absorbers and NEG(?).

• The same harmful effect by heating can be seen widely in arc sections too. A major problem for further improvement of pressure.

Page 13: Vacuum Pressures at IR

Remedies to heating• Main reason of the heating is HOM.

• Tentative measure = Cooling from outside[Bellows] [Gate Valve]

• Heating of Gate Valves, Stoppers and Bellows– Finger-type RF shield is not enough for

high current– TE mode can easily coupled to modes

outside

symptomatic therapy

Page 14: Vacuum Pressures at IR

Remedies to heating• Future (more essential) measure

– Proposal of a New RF-shield structure– Comb-type RF-shield

– 6 circular-type and 1 race-track-type has been installed in LER, and showed good results.

– Application to gate valves are now planed and a test model will be installed in the ring this winter.

Page 15: Vacuum Pressures at IR

Remedies to heating

• Heating of NEG– Gas desorption from heated NEG had been observed near

collimators.

– HOM (TE-mode) intruded through a grid into pump port.

• Tentative measure = use a special gasket

• HOM absorber were installed finally.

= 6 mmt = 2 mmCu

Lead to heating of other components

Page 16: Vacuum Pressures at IR

Remedies to heating• Heating by other HOM sources, such as

collimators or tapers.

Slot

Beam Chamber

SiC

WingSiC

• Install HOM absorber chamber– Example installed near collimators– HOM absorber = SiC

Require Space ! How about IR?

Page 17: Vacuum Pressures at IR

Summary• The pressures at upstream side of IP is almost less than

1x10-7 Pa, but also affected by the heating of components, such as gate valves, stoppers, tapers, NEG and HOM absorbers.

• The problem had been solved accordingly so far. But, essential (drastic) remedies, such as employing new RF-shield or installing HOM absorbers, will be required for future high current operation.

• Improvement of pumping speeds and cooling capacity are of course important.

Page 18: Vacuum Pressures at IR

References

Page 19: Vacuum Pressures at IR

Present Status• Typical Run(11/09/2004)

Ave. Pressure 10-7 Pa

Beam Current 1.2A x 1.6 A

Lifetime 230, 180

min

Luminosity~1.1x1034cm-2/s

Beam currents are usually limited by any problems in vacuum components

Page 20: Vacuum Pressures at IR

Present Status• Vacuum Aging (arc section, -2004/10/31)

– P/I : 1x10-7 Pa/A– Photo-desorption coefficient, : 3x10-7 mole./photon– Effect of photoelectrons were eliminated by magnets.– HER seems to be effected by heating of components.

(If S = 0.3 m3/s/m)

[PM]:Set permanent magnets to every gauge port

P/IMax. I Max. IP/I

PM

PM

[Pa

/mA

]

[Pa

/mA

]

[mA

]

[mA

]

[LER] [HER]

(Corrected)

Page 21: Vacuum Pressures at IR

Present Status• Vacuum pressures in HER (~300 gauges)

Just near to GV!

(ARES)(ARES)

(SCC) (SCC)


Top Related