Download - Vitrex® product catalog online 2015
Different needs...
...Different Tubes In glass & plastic
Even if our standard range of capillary tubes is probably the most comprehensive available worldwide and should cover most requirements, we have - in close cooperation with our customers - developed a remarkable variety of tailor made liquid handling solutions, which far exceeds our standard dimensions. We know from experience that small changes and product modifica-tions are of great significance for biotechnological applications etc. and it´s part of our strategy to bring more focus on customized manufacturing.
Thomas Frismark van NekArea Export Manager
Direct phone +45 2252 9273 [email protected]
Anders Høgfeldt PedersenSales & Marketing Manager - CSO
Direct phone +45 4450 8031 [email protected]
We have become the largest manu-facturer of capillary tubes in the world today by developing equipment,
establishing technologies, and optimising production processes. This is a position we are very proud of having achieved - and we intend to keep it. Today, Vitrex Medical a/s also develops and markets lancets and lan- cing devices, as well as pipettes and related products for a variety of segments within the health care sector. Our products meet all relevant international standards and we carry ISO 9001 and ISO 13485, the CE mark and we are FDA registered. Vitrex products are exported to more than 80 countries all over the world. Our customers include international organisations, government institu-tions, large national importers/distributors and large OEM customers. Each market has its unique culture, needs and demands. From the beginning of Vitrex Medical, the “locomotive” in the develop-ment of the company has been the production facilities in Denmark. And in accordance with our philosophy these facilities, as well as R&D, will remain in Denmark, supplemented by a worldwide network of selected production partners and sub-suppliers. In addition to the comprehensive, standardised range of products, we have developed a large variety of specialised products, i.e. high preci-sion volumetric pipettes, pulling pipettes for a.o. genemanipulation, and a variety of other highly specialised glass tubes. The vast varieties of experience gathered from more than 45 years of developing products within our field makes us an attractive and versa-tile partner in development and business. With this in mind our focus is to meet our customers’ demands for: Quality – Reliability – Economy and Flexibility. In short: advanced simplicity
About us
4
Vitrex® Micro haematocrit tubes
Vol. 1
L +Vol. 2
d
D Standard MicrohaematocritColour Code Impregnation d (mm)
+/- 0.05 mmD (mm)
+/- 0.05 mmL (mm)
+/- 0.5 mm Vol. ( μl ) Article no.
10 x 100Article no.
1 x1000Plain 1.15 1.55 75 ~75 160213 163213
Sodium Hep. 1.15 1.55 75 ~75 161313 163613
Ammon. Hep. 1.15 1.55 75 ~75 160813 164013Lithium Hep. 1.15 1.55 75 ~75 161813 *
Non-standard MicrohaematocritColour Code Impregnation d (mm)
+/- 0.05 mmD (mm)
+/- 0.05 mmL (mm)
+/- 0.5 mm Vol. ( μl ) Article no.
10 x 100Article no.
1 x 1000Plain 0.95 1.35 75 ~50 160413 163413
Sodium Hep. 0.95 1.35 75 ~50 161513 163813Sodium Hep. 1.15 1.55 70 ~70 164413Ammon. Hep. 0.95 1.35 75 ~50 * *Lithium Hep. 0.95 1.35 75 ~50 * *
Precal MicrohaematocritColour Code
Impregnation d (mm) Tol. d. mm D (mm) +/- 0.05 mm
L (mm) +/- 0.5 mm
Vol. 1 ( μl ) Vol. 2 ( μl ) Article no. 10 x 100
Sodium Hep. 0.55 +/-0.05 1.55 75 ~14 ~18 162713Ammon. Hep. 0.55 +/-0.05 1.55 75 ~14 ~18 162813Lithium Hep. 1.023 +/-0.008 1.50 75 32 ~61 161113
For EDTA please contact us Accessories
Article no. Wax plate 2 x 5 140013
* available upon request
VITREX micro-haematocrit tubes are quality products that conform to international standard ISO 12772. The tubes are supplied fire polished at the colour-coded end which we recommend should be sealed with VITREX Sigillum Wax. Fire polishing reduces wear on the centrifuge seals. Supplied with colour-coding on the packaging and on the tubes in plain (blue colour), or with uniform sodium heparinisation (red colour), ammonium heparinisation (green colour) or lithium heparinisation (or-ange colour). Each heparinised tube contains at least 4 IU heparin as prescribed by the Standard.
PackagingThe tubes are available in two types of packaging: Dispenser vials of 100 tubes each for hy gienic and easy handling; and economy cardboard boxes which reduce transport and hand ling costs. Special requirements regarding marking, dimen sions or impregnation can be met. AccessoriesThe Sigillum Wax plate has 2x24 numbered positions per pair which makes it easy to seal and transport samples. Each pair can be forced apart and used separately. The even wax layer ensures uniform sealing. Wax Plates See page 5 Alcohol Swabs See page 36 Lancets See page 26-35
5Micro haematocrit tubes
Vitrex® Micro Pipettes (end-to-end)
L
Vol.
6
Technical Specs. Vol. ( μl ) Colour code pcs L (mm) +/- 1mm Plain Natrium Hep. Ammon. Hep.
0.5 10x100 15 177613 * *1 10x100 29 165013 167513 169013
2 10x100 29 165113 167613 169113
3 10x100 29 165213 167713 169213
4 10x100 29 165313 167813 169313
5 10x100 29 165413 167913 169413
10 10x100 29 174313 177113 179213
20 10x100 29 174513 177213 179313
25 10x100 29 174613 177313 179413
40 10x100 29 174813 177413 179513
44.7 10x50 29 175013 177713 178613
50 10x50 29 174913 177513 179613
* available upon requestFor lithium hep. & EDTA please contact us
AccessoriesArticle no.
Pipette holder 140413
7Micro Pipettes (end-to-end)
VITREX end-to-end pipettes are for users who re-quire easy and very accurate capillary tube volume measurement. The pipettes are manufactured to ISO 7550.
Packaging Packaging Glass vials containing 100 pcs. (50 μl - 50 pcs.) The vials have a dispenser top, making it easy to shake out one tube at a time, thereby ensuring hygienic hand ling. Capillary Tube Dispenser See page 14-15 Alcohol Swabs See page 36
The dispenser tops are colour-coded to indicate the tube volume in conformity with ISO 1769. Ten vials are packaged in a sturdy carton in order to protect the tubes from damage during handling or transport. VITREX tolerances
Acc CV0.5 - 10 μl ± 0.50% 0.75%20 - 100 μl ± 0.50% 0.60%
Colours and volume
Vol. 1,2,3,4,5 5 10 5-10 20 25 40 20-40 44.7 50 20-50 100 50-100 100-200
plain 128813 126013 126213 125513 126413 126613 129313 125913 126813 127013 125613 127213 125713 129413
Na-hep 128913 127413 127613 125213 127813 128013 128413 129913 128213 128513 129113 128613 127113 127713
Other coatings available upon request i.e. Lithium, Ammonium, EDTA.
Vitrex® Precalibrated Pipettes VITREX pre-calibrated pipettes are for users who require very accurate capillary tube volume. The pipettes are manufactured to ISO 7550.
Packaging ckaging Cardboard vials of 250 except 100-200 μl which is packed in vials of 125. The tubes are in a standard length of 125 mm and each tube is provided with a colour code for the volume from its base up to the ringmark.
VITREX tolerancesAcc CV
1-5 μl ± 0.30% 0.60%10-200 μl ± 0.25% 0.50%
Vol.
9Precalibrated Pipettes
8
Capillary Tube Dispenser See page 14-15
Technical Specs. Vials of Na Hep. Article No. Li Hep. Article No. d (mm) +/- 0.05 mm D (mm) +/- 0.05 mm L (mm) +/- 1 mm Vol. ( μl )
4 x 250 182513 182613 1.6 2.3 75 130 (min)
4 x 250 182413 183313 1.6 2.3 100 175 (min)
4 x 250 182313 182013 1.6 2.3 125 220 (min)
Accessories Article No. Description
10 x 500 140813 End caps
10 x 250 140913 Stirrers
Vitrex® Blood gas capillary Tubes
Packaging Choose your Vitrex blood-gas-capillary tubes according to diagram shown below. Just indicate article number and type.
The types have been manufactured under strict control and are in accordance with current standards available in 3 lengths: 75 mm,100 mm and 125 mm. Packed in vials of 250 pcs. Special types upon request.AccessoriesStirrers packed in vials of 250 pcs.End-caps packed in boxes of 500 pcs.
L
Vol.
d
D
Vitrex disposable capillary tubes for blood gas analyses are made from heavy walled glass, suitable for 2.3 mm Ø adaptors.
Uniform heparinisation, careful fire polishing, heavy walled tubes and robust end-caps secure proper function and reduce operating risk. The strict demands on function and quality for the VITREX products are your guarantee.
11Blood gas capillary tubes
10
Vitrex® Capillary & Melting point TubesVITREX capillary tubes and melting point tubes are quality products perfect for the handling and trans-port of small volumes of liquid, melting point deter-minations and many other purposes. The tubes are uniform and are cut at right angles.
Packaging Packaging Select your VITREX capillary or melting point tubes from the table below. The tubes are supplied in vials of 100 or in boxes of 500 or 1000. Customers’ re-quirements for other dimensions, tolerances, sealing and impregnation can usually be met.
L
d
D
Technical Specs. d (mm) +/- 0.05
D (mm) +/- 0.05
L (mm) +/- 1
Both ends open One end Closed Quantity
0.80 1.00 80 210013 218013 20000.80 1.00 100 210113 218113 20000.90 1.20 70 210213 218213 10000.90 1.20 100 210313 218313 10001.00 1.40 75 210413 218413 10001.00 1.40 80 210513 218513 10001.00 1.40 100 210613 218613 10001.00 1.40 125 210713 218713 10001.00 1.40 150 210813 218813 10001.00 1.40 200 210913 218913 50001.15 1.55 80 211013 219013 10001.15 1.55 100 211113 219113 10001.20 1.65 75 211213 219213 5001.20 1.65 100 211313 219313 5001.20 1.65 125 211413 219413 10001.20 1.65 150 211513 219513 10001.20 1.65 200 211613 219613 30001.40 1.90 125 211713 219713 5001.50 2.00 75 211813 219813 5001.50 2.00 100 211913 219913 500
For any other packaging please don´t hesitate to contact us
12
13Capillary & Melting point tubes
Vitrex® Capillary Tube DispenserFULLY AUTOCLAVABLE Autoclavable at 121oC & 15 psi. LOW COST This capillary tube dispenser is specially designed for use with Diagnostic Kits. UNIQUE TIP CONES designed to accept most VITREX® Capillary Tubes. PRACTICAL SIZE At a length of 130 mm this dispenser is the optimum practical size for blood collecting.
Ready 1. Stage 2. Stage
Two-step plunger operationFacilitates super blow-out from the tip.
15Capillary Tube Dispenser
Recommended use
Step 1: Loading the deviceInsert an unused capillary tube into the pipette tip. The end of the capillary must be visible in the tip.
Step 2: Filling the capillaryHold the pipette horizontally and let the capillary fill by capillary action. Be sure not to press the plunger of the pipette.
Step 3: Emptying the capillaryEmpty the capillary by pressing the plunger gently to the first stage. The liquid will be dispensed, but a small amount of liquid will be left in the capillary. After a pause continue to depress the plunger to the second stage. The small amount of liquid left in the capillary is also dispensed.
Step 4: After useRemove the capillary carefully and discard in a suitable safety container.
Step 1
Step 4
Step 2 Step 3
Warning: The plunger must only be used for emptying the capillary. If used for filling the capillary, liquid can accidentally be sucked into the device.
14
Technical Specs.
Colour code Volume µL Packing Article No.
Grey Most Vitrex Capillary Tubes
1 569013
16
State of the art Sutures with a simple ordering systemMade in Europe
Packaging fixates needle and is
easy to open
Pull-out force is controlled 100%
Top grade Japanese stainless steel
Flexible range
Our surgical sutures are manufactured in line with state of the art technology. Each individual produc-tion process is subject to strict scientific quality con-trol. Continous inspection of both mechanical and microbiological characteristics is given top priority. We have 75 years of experience in manufacturing surgical suture. Classical materials such as catgut and silk have been supplemented by a large number of synthetic fibres. The result is the current modern product range of absorbable and non−absorbable sutures which for the meantime amounts to more than 1500 individual products. Production takes place in accordance with GMP guidelines and a comprehensive quality manage-ment system in line with ISO 13485 has been imple-mented. All products have been CE marked since 1999.
17Surgical Sutures
Our ordering systemRead the guide, enabling you to choose from more than 1500 articles
SLA 030B 045C GD 031E 1F 01G
A Thread Type - Our comprehensive product range, of absorb-able and non absorbable threads. In the example above we have used SILK BRAIDED a.i. SL
B Thread size in USP - in the exsamble we have used USP 3/0
C Thread length - standard is 45 or 70 cm but other lengths are available
D Thread color - in the example we have used green
E Needle type - In our comprehensive needle range you will find a needle that meets your requirements
F Packaging in dozens
G Special combinations of thread and needle
18
State of the art Sutures Thread type
Thread type Absorbable
19Surgical Sutures
Absorbable Non absorbable Non absorbable
MC Monolac monofil(MC)
CR Chirlac rapid(CR)
CB Chirlac braided(CB)
PX Polydox(PX)
CF Chiraflon(CF)
CL Chiralen(CL)
SM Silon monofil(SM)
TR Tervalon(TR)
TP Tervalon plus(TP)
SB Silon braided (SB)
OB Orsilon braided(OB)
SL Silk braided(SL)
ST Silk twisted (ST)
Product name Description Application Properties
Monolac violet and natural
Monofilament fromGlycolide and ε−caprolactone
Designed for use in general soft tissue approximation,urology, gynecology, plastic and gastrointestinal surgery.
Monofilament with high tensile strength and excellent handling properties. Monolac violet retains 7 days after implantation ca. 60 % (natural ca. 50%) and after 14 days ca. 30% (natural ca. 20%) of it´s original tensile strength. Absorption is completed between 90-120 days.
Chirlacrapid braidedviolet and natural
Braided suture from coated Polyglycolicacid
Closure of skin, particularly in paediatric surgery, gynaecology(e.g. episiotomies), ophthalmic surgery (e.g. conjunctive suturing)
The thread is coated with an absorbable substance. This reduce the capillary effect. High tensile strength. 5 days after implantation approximately 60 % of it´s original tensile strength remain. All of the original ten-sile strength is lost by appr. 12 to 14 days post impl. Completely material absorption 30–40 days.
Chirlac braidedviolet and natural
Braided suture from coatedPolyglycolicacid
For use in general soft tissue ap-proximation and/or ligation, for the adaptation of muscles and fasciae, for suturing of parenchymalorgans, peripheral nerves, for ligatures of small vessels and for intradermal suturing.
The thread with high tensile strength is coated with an absorbable substance.This reduces the capillary effect. 14 days after im-plantation appr. 75 % of it´s original tensile strength remain. 21 days after implantation appr. 50 % of it´s original tensile strength remain. Absorption is com-pleted after 80-90 days.
Polydoxviolet
Monofilament from Poly(p−dioxanone)
For use in general soft tissue ap-proximation. These sutures are par-ticularly useful where the combina-tion of an absorbable and extended wound support is desirable.
Monofilament with excellent knotting properties and high tensile strength. 6 weeks post implanta-tion the thread remain ca. 50 % of it´s original tensile strength. After 180-210 days it is completely absorbed.
16Thread type Non-absorbable
USP system
Product name Description Application Properties
Chiraflon blue
Monofilament from PVDF (similar to Teflon)
For use in all surgical branches, cardiovascular surgery, orthopedics, traumatology (tendons), plastic and ophtal-mologic surgery(optimal temporary easily removable suture).
Physiological inert. Very smooth, best knotting properties. Easy to handle. No capillary effect.
Chiralen blue, black
Monofilament from Poly-propylene
For use in all surgical branches, especially cardiovascular surgery, orthopedics, traumatology (tendons), plastic and ophtalmologic surgery (optimal temporary easily remov-able suture).
Smooth, nonporous surface. No capillary effect. Suited for stitches in infected wounds.
Silon monofilblue, black
Monofilament fromPolyamide – 6
Silon monofil is suitable for plastic and general surgery and whenever the skin is sutured. Depending on the site of implantation and wound condition, the skin suture is normally removed within 30 days.
Very smooth, best knotting prop-erties. Easy to handle. Loss of tensile strength after long time implantation.
Tervalongreen
Braided suture from polyester−fiber, coated
Tervalon is applicable whenever non−absorbability and low friction passage through tissues are needed. It is use-ful in many applications including for cardiovascular use. Tervalon is suitable for permanent continuing suture and for long term intradermal suture.
High tensile strength, well toler-ated from the tissue. No capil-lary effect. Low friction.
Tervalon Plus green, white
Braided poly-ester suture, coated with PTFE
Special designed for cardiovascular surgery. The PTFE coating reduces dead space.
High tensile strength, no capil-lary effect and very low friction.
Silon braided
Orsilon braidedwhite
Braided sutures from poly-amide
Silon/ Orsilon braided is suitable for suturing skin, subcutaneous tissue, transversely cut muscles, fascia, peritoneum, the organs of the gastrointestinal tract and blood vessels ligation.
High tensile strength, safe knotting properties. Loss of tensile strength after long time implantation
Silk braidedblue, black
Braided silk suture Silk braided is suitable for suturing skin, subcutaneous tissue, fascia, peritoneum and the organs of the gastroin-testinal tract.
Hydrophobe coated, no capillary effect. Loss of tensile strength after long time implantation.
Silk twistedblue, black, white
Natural twisted Silk braided is suitable for suturing skin, subcutaneous tissue, fascia, peritoneum and the organs of the gastroin-testinal tract.
Hydrophobe coated, no capillary effect. Loss of tensile strength after long time implantation.
The publication of the European Pharma-copoeia (Ph. Eur.) resulted in a standardi-zation of the classification of threads and gauges of surgical suture material. The Ph. Eur. specifies a decimal classifi-cation and metric coding for the gauges. It quotes a thread diameter of 1/10 mm, so that the thread gauge of 3.5 has a diameter of 0,35 mm. The following table of the gauges gives a comparison of the metric and the USP gauge coding.
EP/Metric
0.2 0.3 0.4 0.5 0.7 1 1.5 2 3 3.5 4 5 6 7 8
USP 10–0 9–0 8–0 7–0 6–0 5–0 4–0 3–0 2–0 0 1 2 3+4 5 6
Ø (mm) 0.020–0.029
0.030–0.039
0.040–0.049
0.050–0.069
0.070–0.099
0.100–0.149
0.150–0.199
0.200–0.249
0.300–0.349
0.350–0.399
0.400–0.499
0.500–0.599
0.600–0.699
0.700–0.799
0.800–0.899
Ø (mm) Absorbable monofila-ments
0.050–0.094
0.095–0.149
0.150–0.199
0.200–0.249
0.250–0.339
0.340–0.399
0.400–0.499
0.500–0.570
0.571–0.610
Thread length & color
C Thread length - usually 45 or 70 cm But other lengths are available
D Thread color - in the example we have used greenG - Green V - Violet
W - White K - Black
N - Naturel B - Blue
Needle type
Clinicians including surgeons, dentists, vets and critical care specialists can choose from a huge variety of top of the line surgical suture needles to ensure perfection of every wound closure with minimal trauma and complications. Our suture needles give you all the options you need to pick the suitable needle for excellent sutured wound care. More than 200 different needle types are available for your selection - from all commonly used surgical suture needles like round-body and cutting needles to more specialized spatula-type needles for microsur-gery. We never compromise on quality. Our suture needles are crafted from premium quality Japanese stainless steel. Our unique needle-thread combinations guarantee minimal resistance to penetration and effortless passage through the tissue.
Most commonly used needles
Roundbody needle, trocar point
Roundbody needle
Roundbody needle, blunt point
Triangular body needle, reverse cutting
Order Art no. Description
J-RT060 J-RT 30 Hook shaped, round body needle,
trocar pointHR070 HR 8 1/2 circle - round body needle071 HR 10 1/2 circle - round body needle072 HR 13 1/2 circle - round body needle073 HR 13 A 1/2 circle - round body needle,
take off074 HR 15 1/2 circle - round body needle075 HR 17 A 1/2 circle - round body needle,
take off076 HR 18 1/2 circle - round body needle077 HR 18 A 1/2 circle - round body needle,
take off078 HR 22 1/2 circle - round body needle079 HR 22 A 1/2 circle - round body needle,
take off080 HR 27 1/2 circle - round body needle081 HR 27 A 1/2 circle - round body needle,
take off082 HR 30 1/2 circle - round body needle083 HR 30 A 1/2 circle - round body needle,
take off084 HR 35 1/2 circle - round body needle085 HR 40 1/2 circle - round body needle086 HR 50 1/2 circle - round body needle087 HR 60 1/2 circle - round body needle088 HR 43 1/2 circle - round body needle089 HR 36 1/2 circle - round body needle090 HR 65 1/2 circle - round body needle091 HR 37 1/2 circle - round body needle092 HR 25 1/2 circle - round body needleKR100 KR 27 Ski needle - round body
Order Art no. Description
000 without needleDR010 DR 3,75 3/8 circle - round body needle011 DR 5,1 3/8 circle - round body needle012 DR 6,5 3/8 circle - round body needle013 DR 8 3/8 circle - round body needle014 DR 10 3/8 circle - round body needle015 DR 12 3/8 circle - round body needle016 DR 15 3/8 circle - round body needle017 DR 18 3/8 circle - round body needle018 DR 21 3/8 circle - round body needle019 DR 31 3/8 circle - round body needleDRT030 DRT 8 3/8 circle - round body needle,
trocar point031 DRT 8 Black 3/8 circle - round body needle,
trocar point032 DRT 10 3/8 circle - round body needle,
trocar point033 DRT 13 3/8 circle - round body needle,
trocar point034 DRT 10 Black 3/8 circle - round body needle,
trocar pointART040 ART 30 black asymmetric, round body needle,
trocar point
J-RX050 J-RX 22 Hook shaped, round body
needle
21Surgical Sutures
20
Two-step plunger operation facilitates super blow-out from the tip.
Stage 1: Depress the plunger to the first stage to aspirate the fluid. Place the tip of the micropi-pette in the desired fluid. Slowly release the pressure and allow the plunger to rise allowing the fluid to aspirate.
Stage 2: Transfer the fluid to the desired location by again depressing the plunger to the first stage. Press the plunger in full (second stage) in order to fully dispense the fluid.
This operation also allows the VITREX® PIPETTE Fixed to be used for both reverse and repetitive pipetting.
Ready 1. Stage 2. Stage
The tip cone of the VITREX® PIPETTE Fixed (5µl and 10µl) is designed to accept both regular 200µl tips or ultra micro tips up to 10µl. Use of ultra micro tips for volumes up to 10µl significantly enhances the accuracy and precision.
Recommended pipetting procedure: Pre-wet the tip two times. Dip 2-4mm into fluid.Touch the wall for smooth aspiration and dispensing.
Technical Specs. Colour Vol. μl Accuracy ±% Precision CV% Packing Article No.White 5 1.5 1.0 1 560013Orange 10 1.0 1.0 1 561013Black 20 0.5 0.5 1 562013Grey 25 0.5 0.5 1 563013Green 50 0.4 0.3 1 564013Blue 100 0.3 0.3 1 565013Red 200 0.5 0.5 1 566013
22
Needle type
Order Art no. Description
HRX110 HRX 13 1/2 circle - round body
needle, extra strong111 HRX 22 1/2 circle - round body
needle, extra strong112 HRX 27 1/2 circle - round body
needle, extra strong113 HRX 35 1/2 circle - round body
needle, extra strong114 HRX 40 1/2 circle - round body
needle, extra strong115 HRX 45 1/2 circle - round body
needle, extra strong116 HRX 50 1/2 circle - round body
needle, extra strong117 HRX 50 A 1/2 circle - round body
needle, take off118 HRX 70 1/2 circle - round body
needle, extra strong119 HRX 37 1/2 circle - round body
needle, extra strong120 HRX 43 1/2 circle - round body
needle, extra strong121 HRX 30 1/2 circle - round body
needle, extra strong122 HRX 40 A 1/2 circle - round body
needle, extra strong, take off
HRTX130 HRTX 50 1/2 circle - round body
needle, extra strong, trocar point
131 HRTX 37 1/2 circle - round body needle, extra strong, trocar point
132 HRTX 44 1/2 circle - round body needle, extra strong, trocar point
Order Art no. Description
HRs140 HRs 18 1/2 circle, rectangular
body needle, slim141 HRs 18
Black1/2 circle, rectangular body needle, slim
142 HRs 22 1/2 circle, rectangular body needle, slim
143 HRs 22 Black
1/2 circle, rectangular body needle, slim
144 HRs 25 1/2 circle, rectangular body needle, slim
145 HRs 27 1/2 circle, rectangular body needle, slim
146 HRs 27 Black
1/2 circle, rectangular body needle, slim
HRT160 HRT 13 1/2 circle - round body
needle, trocar point161 HRT 17 1/2 circle - round body
needle, trocar point162 HRT 17 A Peel needle163 HRT 25 1/2 circle - round body
needle, trocar point164 HRT 30 1/2 circle - round body
needle, trocar point165 HRT 37 1/2 circle - round body
needle, trocar point166 HRT 22 1/2 circle - round body
needle, trocar point167 HRT 45 1/2 circle - round body
needle, trocar point168 HRT 48 1/2 circle - round body
needle, trocar point169 HRT 10 1/2 circle - round body
needle, trocar point170 HRT 20 1/2 circle - round body
needle, trocar point
Order Art no. Description
FR175 FR 27 5/8 circle, round body
needle176 FR 38 5/8 circle, round body
needleGR180 GR 20 Straight round body
needle181 GR 45 Straight round body
needle182 GR 60 Straight round body
needleGS190 GS 13 Straight needle,
reverse cutting191 GS 60 Straight needle,
reverse cutting192 GS 50 Straight needle,
reverse cuttingDSM200 DSM 8 3/8 circle, reverse cut-
ting needle, micropoint201 DSM 12 3/8 circle, reverse cut-
ting needle, micropoint202 DSM 15 3/8 circle, reverse cut-
ting needle, micropoint203 DSM 19 3/8 circle, reverse cut-
ting needle, micropoint204 DSM 25 3/8 circle, reverse cut-
ting needle, micropoint205 DSM 6,5 3/8 circle, reverse cut-
ting needle, micropointDRN210 DRN 60 3/8 circle, round body
needle, blunt pointHRN220 HRN 50 1/2 circle, round body
needle, blunt point
Order Art no. Description
DS230 DS 10 3/8 circle,
reverse cutting needle231 DS 12 3/8 circle,
reverse cutting needle232 DS 15 3/8 circle,
reverse cutting needle233 DS 19 3/8 circle,
reverse cutting needle234 DS 25 3/8 circle,
reverse cutting needle235 DS 30 3/8 circle,
reverse cutting needle236 DS 38 3/8 circle,
reverse cutting needle237 DS 40 3/8 circle,
reverse cutting needle238 DS 90 3/8 circle,
reverse cutting needleHS250 HS 12 1/2 circle, reverse
cutting needle251 HS 15 1/2 circle, reverse
cutting needle252 HS 18 1/2 circle, reverse
cutting needle253 HS 21 1/2 circle, reverse
cutting needle254 HS 25 1/2 circle, reverse
cutting needle255 HS 30 1/2 circle, reverse
cutting needle256 HS 37 1/2 circle, reverse
cutting needle257 HS 40 1/2 circle, reverse
cutting needle258 HS 48 1/2 circle, reverse
cutting needle259 HS 50 1/2 circle, reverse
cutting needle260 HS 55 1/2 circle, reverse
cutting needleHSX265 HSX 23 1/2 circle, reverse
cutting needle extra strong
DLZ270 DLZ 6,2 3/8 circle, spatulated271 DLZ 6,4 3/8 circle, spatulatedVLZ280 VLZ 8 1/4 circle, spatulatedGLZ290 GLZ 16 Straight, spartulatedHLZ300 HLZ 8 1/2 circle, spatulated
Packaging & Variants
Packaging 1 12 pcs 1 dozen
2 24pcs 2 dozen
3 36 pcs 3 dozen
4 20 pcs Chirapack
5 1pcs bottles
FVariant LO loop12 1 pcs thread, 2x needle on one thread50 5pc of thread, 0 pc of needle66 6x needle 6x thread (6 times the same products)ME meshLA L- loop, A -applicator - for minimal invasive surgeryFC fix clip
G
A Thread Type - Our comprehensive product range, of absorbable and non absorbable threads. In the example above we have used SILK BRAIDED a.i. SL
B Thread size in USP - in the exsamble we have used USP 3/0
C Thread length - standard is 45 or 70 cm but other lengths are available
D Thread color - in the example we have used green
E Needle type - In our comprehensive needle range you will find a needle that meets your requirements
F Packaging in dozens
G Special combinations of thread and needle
Pick your appropriate suture - it´s easy
LOW COST - This miniature fixed volume pipette is specially designed for use with Diagnostic Kits.
HIGH ACCURACY AND PRECISION - Each pipette is individually calibrated as per the ISO 8655 standard.
COLOUR CODED Each pipette is colour coded for different vol-umes ersuring easy identification in the laboratory environment.
TWO STEP PLUNGER OPERATION - This unique fea-ture makes the pipette a genuine miniature micropipette.
PRACTICAL SIZE - At a length of 130 mm this pipette is the optimum practical size for the pipetting function.
FULLY AUTOCLAVABLE - Autoclavable at 121oC & 15 psi.
Vitrex® Pipette Fixed
23Surgical Sutures
VITREX® syringes Luer/Luer-Lock, 3-part for single use
The syringes are sterile, pyrogen-free, non-toxic, made of plastic. They consist of a barrel with printed scale, piston and a rubber stopper made of natural LATEX FREE rubber. The division of the scale is in milliliters. The cone of the sizes of 1, 2, 5, and 10 ml is located centrically and the sizes of 20, 30, 50 ml eccentrically.
The cone of the size of 50ml is Luer Lock and Catheter type. The cone of the size of 100ml is Catheter type with luer adapter.
Size Luer Luerlock Packaging
1 ml 570113 200
2 ml 570213 571213 100
5 ml 570313 571313 100
10 ml 570413 571413 100
20 ml 570513 571513 50
30 ml 570613 571613 40
50/60 ml 570713 50
50/60 ml 571713 16
Size Catheter Packaging
50/60 ml 572013 16
100 ml 572113 25
Luer/Luer-Lock, 2-part syringes for single use
Size Luer Luerlock Packaging
2 ml 573013 574013 100
5 ml 573113 574113 100
10 ml 573213 574213 100
20 ml 573313 574313 50
VITREX® Insulin and tuberculin syringesVitrex 0.5 ml and 1 ml syringeswith integrated needle for single use.
Insulin syringes are available with 27G and 29G needle - U100 or U40 scale, and are fitted with an orange needle cap. Tuberculin syringes are sup-plied with a 29G needle and a blue needle cap. 0.5 ml and 1 ml syringes with integrated needle for vaccination etc. with 27G and 29G needle, are also supplied with blue end cap.
The syringes are individually peel packed, in boxes of 100 pcs. They are pyrogen-free and non-toxic. The rubber stopper is made of LATEX-FREE natural rubber.
Type Vol. Units Needle Colour
U 100 Insulin 29G 1.0 ml U 100 29G x 1/2” Orange
U 100 Insulin 27G 1.0 ml U 100 27G x 1/2” Orange
U 100 Insulin 29G 0.5 ml U 100 29G x 1/2” Orange
29G Tuberculin 1.0 ml - 29G x 1/2” Blue
U 100 insulin 1.0 ml U 100 - Clear
Tuberculin 1.0 ml U 100 Clear
VITREX® Hypodermic Single-use needles The outstanding feature of the needles is their high-quality point which reduces the patient’s dis-comfort at penetration.
Gauge 12 mm 16 mm 20 mm 40 mm Colour
30 G 575013 Light yellow
27 G 575113 575413 576213 577413 Grey
Gauge 12 mm 16 mm 20 mm 25 mm Colour
26 G 575213 575513 576313 577513 Brown
25 G 576413 577613 Orange
Gauge 25 mm 40 mm Colour
24 G 576513 577713 Purple
Gauge 25 mm 30 mm 40 mm Colour
23 G 575613 576613 577813 Blue
Gauge 30 mm 35 mm 40 mm 50 mm Colour
22 G 575313 575713 576713 577913 Black
Gauge 25 mm 40 mm 50 mm Colour
21 G 575813 576813 578013 Green
20 G 575913 576913 578113 yellow
19 G 576013 577013 578213 Ivory
18 G 576113 577113 578313 Pink
18 G Short bevel 577213 Pink
15 G 577313 Blue Grey
24
25Syringes
Vitrex® Steriheel BabySterile Cutting Safety lancetFor high volume blood flow with minimum depth of penetration
USER SAFETY: Blade is fully shielded before and after use.
ACTIVATION BUTTON secured by safety rod.
USER CONVENIENCE: Pre-loaded, button activated design.
PATIENT SAFETY: Single-use only. Cannot be re-used. Sterilised by gamma irridiation.
CONTROLLED PENETRATION DEPTH
PATIENT COMFORT: Ultra sharp blade with high speed action securing minimal trauma and fast healing.
HIGH BLOOD FLOW: The controlled movement of the blade is designed to optimise blood flow.
APPLICATION: Primarily newborns and preemies. Can also be recommended for other applications where short penetration depth and/or minimal compression of tissue is important.
1. Pull off the safety rod (prevents premature firing).
2. Reference position for infant heel blood sampling.
3. Press the device firmly against the infants heel and release the lancet.
4. Collect the blood sample with a capillary tube.
5. Dispose of the safety lancet in a suitable safety container.
WARNING: Do not use if protective rod has previously been removed or if the shield blister packing has been damaged.
Packaging: Blister PackedPrimary packaging: 50 pcs Transit packaging: 200 pcsPallet: 24000 pcs
Transit packaging Pallet
Recommended use
27Baby Cutting Safety Lancet
26
Technical Specs. Colour Code
Specification Article No. Application
Pink 1.14 mm Depth / 2.80 mm Incision Length 332113 Newborn
Yellow 1.00 mm Depth / 2.50 mm Incision Length 333113 Newborn
Orange 0.85 mm Depth / 1.75 mm Incision Length 334113 Preemie
Green 0.65 mm Depth / 1.40 mm Incision Length 335113 Preemie
Shelf life 5 years
12
3
4 5
Vitrex® Sterilance Press II Sterile Safety lancetHealth workers worldwide face accidental needle-stick injury while caring for patients, putting themselves at risk to blood-borne illnesses including the AIDS virus and Hepatitis.
USER SAFETY needle is fully shielded before and after use.
USER CONVENIENCE pre-loaded, pressure activated design.
PRESSURE ACTIVATION ensures a good blood sample every time.
PATIENT COMFORT high quality, ultra sharp tri-bevel needle or bi-bevel blade, high speed penetration.
EFFICACY variety of point configurations and penetration depths to suit most capillary blood requirements.
APPLICATION blood glucose and other in vitro diagnostic tests.
PATIENT SAFETY sterile, single-use, unable to be re-used.
WARNING: Do not use if protective safety cap has previously been removed.
Technical Specs. Colour Code Configuration Penetration Depth Article No. Application
Green 18G blade 1.8 mm 393213 Special baby care and maternity units for heel puncture
Yellow 26G needle 1.8 mm 394213 Diabetes clinics/hospital wards for blood glucose monitoring
Orange 21G needle 2.2 mm 395213 Haemoglobin (blood banks), cholesterol, blood typing, coagulation, blood gas and other diagnostic tests
Pink 21G needle 2.8 mm 396213 As Orange but for thicker adult skin
Blue 21G needle 1.8 mm 397213 As Yellow but for increased blood flow
Purple 28G needle 1.8 mm 398213 New item, less pain
Shelf life 5 yearsPackagingPrimary packaging: 100 pcs Transit packaging: 1000 pcsPallet: 98000 pcs
Transit packaging
Pallet
Recommended use
29Press II Safety Lancet
28
1. Carefully twist off the protective cap.
2. Select site and press the device firmly against the site to release the lancet.
3. Dispose of safety lancet in a suitable safety container.
1
2 3
Vitrex® Sterilance Lite II Sterile Safety lancetFor your safety and patient comfort
USER SAFETY needle is fully shielded before and after use.
USER CONVENIENCE pre-loaded, pressure activated design.
PRESSURE ACTIVATION ensures a good blood sample every time.
PATIENT COMFORT high quality, ultra sharp tri-bevel needle or bi-bevel blade, high speed penetration.
EFFICACY variety of point configurations and penetration depths to suit most capillary blood requirements.
APPLICATION blood glucose and other in vitro diagnostic tests.
PATIENT SAFETY sterile, single-use, unable to be re-used.
Recommended use 1. Twist off the protective cap. 2. Select fingertip insertion site slightly off centre to minimise any discomfort and maximise blood flow.
Hold the lancet firmly against site and press the release button to activate the device.
3. Gently massage the finger in the direction of the puncture site
to obtain the required volume of blood. 4. Dispose of safety lancet in a suitable safety container.
WARNING: Do not use if protective cap has previously been removed.
Shelf life 5 years
Technical Specs. Colour Code
Configuration Penetration Depth
Article No. Application
Green 18G blade 1.8 mm 373113 Special baby care and maternity units for heel puncture
Purple 28G needle 1.8 mm 374113 Diabetes clinics/hospital wards for blood glucose monitoring
Yellow 26G needle 1.8 mm 375113 Diabetes clinics/hospital wards for blood glucose monitoring
Blue 26G needle 2.4 mm 376113 As above but for thicker adult skin
Orange 21G needle 1.8 mm 377113 Haemoglobin (blood banks), choles-terol, blood typing, coagulation, blood gas and other diagnostic tests. For paediatrics and most normal adult skin
Pink 21G needle 2.4 mm 378113 As above but for thicker adult skin
Packaging: Primary packaging: 100 pcs Transit packaging: 1000 pcsPallet: 90000 pcs
Transit packaging
Pallet
31Lite II Safety Lancet
301
2 3 4
Vitrex® Sterilance FlexSterile Safety lancetUSER SAFETY is assured because the needle is fully shielded before and after use.
COMFORT is provided by high quality tri-bevel needle with high-speed penetration.
USER CONVENIENCE adjustable design provides three different penetration depths from a single unit - easy to use pre-loaded and pressure activated device.
PATIENT SAFETY sterile, single-use, unable to be re-used.
PRESSURE ACTIVATION ensures a consistent blood flow with every use.
APPLICATION can be used for blood glucose and other diagnostic tests.
1. Carefully twist and pull off the protective cap WARNING: Do not use if protective cap has previously been removed.
2. Adjust the (adjustable) tip to choose the suitable depth.
3. Push the adjustable safety lancet firmly onto the chosen site to fire.
4. Dispose of the adjustable safety lancet in a suitable safety container.
Technical Specs. Colour Code
Configuration Penetration Depth
Article No. Application
Blue 26G 26G 26G
1.2 mm1.8 mm 2.4 mm
399913 Versatile adjustable lancet for most com-
mon use
Red 28 G 28 G 28 G
1.2 mm1.8 mm 2.4 mm
399813 Versatile adjustable lancet for most com-
mon use
Shelf life 5 years
Packaging: Primary packaging: 100 pcs Transit packaging: 1000 pcsPallet: 84000 pcs
Transit packaging
Pallet
Recommended use
33Flex Sterile Safety Lancet
321
2 3 4
Vitrex® Compact Eject
Suitable for use with VITREX® Soft
Suitable for use with VITREX®Compact Eject
34
Lancing device with push button ejectionSuitable for use with VITREX® Soft and most other popular lancet brands. Variable penetration. Simple, quick activation and reactivation. Simple, non-touch lancet removal. Clear adjustable and clear fixed end caps designed for Alternate Site Testing (AST).
Recommended use 1. Variable penetrationSix depth settings. Dial sets appropriate depth between 1 (minimum) and 6 (maximum).
2. Simple, quick activa-tion and reactivation Pulling back grey slider activates the mechanism.
3. Instant operationDepressing the grey button operates the device.
4. Lancet removalSimple, reliable lancet ejection.
35VITREX® Compact Eject & VITREX® Soft
1
2
3
4
Vitrex® Soft Blood Glucose Lancets 23, 28, 30 & 32 GRANGE OF BLOOD VOLUMES 23, 28, 30 and 32G lancets. GOOD BLOOD FLOW Triple ground needle point.
VERSATILE Fit most commonly used lancing devices including the Vitrex® Compact Eject lancing device.
STERILE Sterilised by gamma irradiation at minimum 25kGy.
CONVENIENT Boxes have dispensing feature.
Technical Specs. Colour Code
Gauge Size Pieces/box Article No.
Light blue
23G (0.65 mm)
200 351213
Red 28G (0.38 mm)
200 352213
Green 30G (0.31 mm)
200 354213
Dark blue
32G (0.26 mm)
200 357213
Shelf life 5 yearsPackaging: Primary packaging: 200 pcs Secondary packaging: 2000 pcs Transit packaging: 20000 pcsPallet: 480000 pcs
Technical Specs. Device & End Caps Description Packaging Article No.
VITREX® Compact Eject 6-step adjustable depth Clear plastic sleeve only 369300
Fixed AST End Cap Clear non-adjustable Clear plastic bag 369091
Adjustable AST End Cap Clear 5-step adjustable Clear plastic sleeve 369092
Vitrex® Steel General Purpose Capillary Blood Lancet
Transit packaging
Pallet
LOW COST Simple, flat, steel lancet. SAMPLE VOLUME Excellent blood flow. HIGH QUALITY Hardened surgical steel. MINIMUM DISCOMFORT Modern asymetric design. STERILE Sterilised by gamma radiation to EN 556 and EN ISO 11137.
Technical Specs. Product Description Article No.
Vitrex Steel - standard Flat blade sterile lancet 350213
Vitrex Steel - allergy Flat blade sterile lancet 365213
Packaging: Primary packaging: 200 pcs Secondary packaging: 10000 pcs Transit packaging: 40000 pcsPallet: 720000 pcs
37Vitrex® Alcohol swabs & Vitrex® Steel
36
VITREX® Alcohol swabs are an easy and con-venient way to cleanse the skin and help fight bacteria at the site of application.
Use as an antiseptic skin cleanser before injections and blood sampling.
Each Alcohol Swab is individually sealed and disposable for convenience and safety.
Technical Specs. Description Size Packing Content Article No.
Alcohol Swab
30 x 60 mm.
100 pcs 70% Isopropyl Alcohol
520213
Shelf life 5 years
Packaging: Primary packaging: 100 pcs Transit packaging: 10000 pcs Pallet: 400000 pcs
Vitrex® Alcohol Swabs
Transit packaging
Pallet
PassionIt seems natural to us to be passionate about every detail, aspect, and element, which characterizes our products. Not only do we take pride in our manu- facturing, we also want to see our customers succeed and stay ahead of the competition.
Constant Attention We continuously adapt our products and services to maximize their effectiveness. We listen carefully, act
change-oriented and never lose focus. As you work with us, you will discover our unique commitment to
customer service.
FlexibilityOur customers benefit from a reputed hi-tech production facility, enabling us to improve a flexible manufacturing of both standard and customized products. We carry ISO 9001 and ISO 13485, the CE mark and are FDA registered.
Pragmatic CompetenceOur approach is pragmatic in the sense that our recommended solutions have been proven reliable and effective for years. Never complicate what is simple. A key part of our technology is designed and engineered by our own technicians.
Global MindsetToday you will find our products in more
than 80 countries worldwide. Being a global player, we know and respect that different
markets have different needs. Our multilingual staff is ready to assist you in finding the right
and innovative solution for your liquid handling needs.
Vitrex® DNA
A d v a n c e d s i m p l i c i t y
Vitrex Medical a/s 201501 JR
rev001 ph:51502823S
ubject to technical changes . Colour deviations possible due to printing m
ethods
Vitrex Medical a/sVasekær 6-8DK 2730 Herlev
Phone +45 4494 7011 Fax +45 4453 1711