Download - VWR symphony Ultra-Low Temperature Freezers
VWR® symphony™ Ultra-Low Temperature Freezers
Large Capacity, Small Footprint
Multiple Alarm Options
Advanced LED Display
Unique Lock Design
5-Year Compressor Warranty
3-Year Parts and Labor Warranty
2
Vacuum thermal insulation technology increases storage space by up to 30%
Easy to clean, zinc-coated steel interior
Cabinet Frame Shelf support
Door lock supporter
Cover for temperature sensor
Inner sealing/gasket
Outer sealing/gasket
Inner door
Standard 7-day temperature chart recorder
Other Design Advantages• Insulation material designed for aircraft heat insulation• Cabinet exterior made of cold rolled steel sheets• Unique manufacturing process for better evaporator
temperature and overall performance• Optimized cascade refrigeration produces more cooling
ability with less power consumed
• Robust compact casters for ease of moving• Unique door seal design for minimal frost formation• Vacuum thermal insulation technology increases storage
space up to 30%
Insulated, dual-pane door
Adjustable inner shelves
Lock is padlock compatible
Easy open handle
Four gasketed inner doors are standard, creating four compartments that can be subdivided with interior shelves
VWR® symphony™ Ultra-Low Temperature Freezers
3
Feature Advantage Benefit
Refrigeration system Balanced, optimized refrigeration system for faster pull-down speed and tighter temperature uniformity. Approximately 15% lower discharge temperature.
Safeguard stored samples. Increased reliability. Reduced heat output to environment, less demand on AC system.
Microprocessor control Keyboard style data entry. Digital display. Automatic lockout feature on control to prevent unintended operation.
Ease of operation, safer, and more accurate.
Self-diagnostics Control system can automatically determine areas that might suggest a system malfunction. Provides a quick and convenient method for maintenance.
Speedy resolution of issues related to freezer system for a better protection of samples.
Real-time display of ambient temperature and line voltage
Instant environmental information and power information for users.
Direct information for users to perform and schedule preventive maintenance (PM) activities.
Programmable delay in restart of units after power outage
Avoid power surge or line sagging when units are attempting to restart after a power outage or generator switchover.
System can bypass harmful transient period to decrease the probability of component damage due to unstable power supply.
On-demand operation of cooling fans
Automatic adjust run time of fans based on ambient demand. Extends fan motor life. Stabilize operating pressures.
Consumes less power and emits lower noise.
Extremely low sound system Specialized design with sound reduction features and system.
Approximately 10 dB quieter than typical competitor units. Better suited for applications in laboratory.
Automatic voltage compensation system
Automatically detects changes in line voltage and adjusts to provide an optimal range of operation for system.
Additional reliability of compressor with intelligent voltage handling system while typical competitor systems only buck or boost voltages.
Protection shield for power switch
Ease of access with proper protection. Improved aesthetics.
Alarm connections easily accessible.
Overcurrent protection Provide alarm signals when there is a severe voltage condition or electrical malfunctions.
Provide safety to operators and samples.
Enforced shelves Double re-enforcement channels to support a heavier load.
Stores large mass and oddly shaped products.
Double silicone-sealed inner doors
Individual inner doors with foamed insulation and double-sealed gaskets.
Lessens temperature impact to other compartments. Provides additional safety for samples. Reduces energy consumption by about 30% compared to similar freezers.
Extended display with backup battery
High capacity battery can sustain display and alarm function for about 72 hours when there is a power outage.
Continuously monitor the freezer temperature even when there is a loss of AC power. Provides temperature information of stored samples.
Network NC/NO contact points for remote alarm system, RS232 and RS485 systems.
Can be connected with PC for remote monitoring.
Can be supported with backup cooling systems
Independent backup cooling system. Auto activation of backup system when there is a loss of main cooling system. Provides a better and timely protection of samples.
Temperature recorder Equipped with temperature recorder as a standard feature.
Reliably tracks temperature.
Lock for external door Padlock compatible. Product safety.
Features and Benefits
4
Alarm Features
Eye-level controls for quick and easy programming and viewing
Equipped with microcomputer and a digital temperature display in a range of -10 to -86°C (14 to -123°F). Normal operating temperature
range is -50 to -86°C (-58 to -123°F).
Advanced LED display on the freezer can display the cabinet temperature, set point, ambient temperature, and line voltage. It also allows the user to set the high temperature alarm, low temperature alarm, and notifies the user through display should the unit develop a failure.
Alarm Alarm Triggering Condition Indicator Buzzer Sound
High Temperature Temperature reaches the warm alarm limit
Alarm indicator flashes Delays 15 minutes to sound intermittently
Low Temperature Temperature reaches the low alarm limit
Alarm indicator flashes Delays 15 minutes to sound intermittently
Power Failure Equipment loses power Alarm indicator flashes; display shows temperature and blank interchangeably
Delays 1 minute to sound intermittently
Improper Voltage Supply voltage exceeds the high or low limits Alarm indicator lights ----
Hot Condenser 1. Condensers filter element is clogged 2. Ambient temperature is too high
Alarm indicator flashes Intermittent
High Ambient Temperature
Ambient temperature exceeds 32°C Alarm indicator flashes Ambient temperature exceeds 38°C, intermittent
Probe Failure Main cabinet temperature control sensor fails Alarm indicator flashes, temperature display alternates to show E2 and cabinet temperature
Intermittent
Condenser sensor fails Alarm indicator flashes, temperature display alternates to show E1 and cabinet temperature
Intermittent
Ambient sensor fails Alarm indicator flashes, temperature display alternates to show E0 and cabinet temperature
Intermittent
Heat exchanger sensor fails Alarm indicator flashes, temperature display alternates to show E3 and cabinet temperature
Intermittent
Low Battery Battery capacity runs low or battery switch is not turned on
During the test, the alarm indicator flashes
----
Operating status display Display for working temperature, setting temperature, high-alarming temperature, low-alarming temperature, password setting, and codes error
Audio/visible alarm
Silencing sound alarm
Malfunction detection
Ambient temperature display
Voltage display
Adjusting key Selecting function
5
Specifications
22 cubic foot freezer
25 cubic foot freezer
28 cubic foot freezer
17 cubic foot freezer
6
Ordering Information
VWR® symphony™ Ultra-Low Temperature Freezers
Designed to provide excellent sample protection while maximizing floor space, these compact, upright units are equipped with an intuitive microprocessor-based controller that includes comprehensive set point, alarm, monitoring, and diagnostic functions. Audible and visible alarm options are available. Remote alarm contacts can be connected to an independent monitoring system. Eye-level controls and LED allow for quick and easy programming and viewing. Freezers feature zinc-coated steel interiors and one insulated, dual-pane door. Four gasketed inner doors
VWR symphony ULT Freezers and AccessoriesDescription Volume, L (cu. ft.) Cat. No. EachULT Freezer, 120V/50Hz 481 (17) 414005-089 11,805.00ULT Freezer, 220V/50Hz 481 (17) 414005-090 11,805.00ULT Freezer, 115V/60Hz 627 (22) 414005-088 15,232.67ULT Freezer, 208/230V 60Hz 627 (22) 414005-087 15,232.67ULT Freezer, 208/230V 60Hz 718 (25.4) 414004-216 16,827.50ULT Freezer, 208/230V 60Hz 809 (28.6) 414004-658 18,725.00AccessoriesReplacement Temperature Chart Recorder — 414004-207 1456.33CO2 Backup System — 414004-206 2179.63LN2 Backup System — 414004-208 2288.46Replacement Shelf, 22 Cu. Ft. — 414004-214 136.36Replacement Shelf, 25 Cu. Ft. — 414004-858 103.48Replacement Shelf, 28 Cu. Ft. — 97059-194 148.76Storage Rack for 2” (5 cm) Boxes, 22 & 25 Cu. Ft. — 414004-220 292.04Storage Rack for 3” (7.6 cm) Boxes, 22 & 25 Cu. Ft. — 414004-212 239.98Storage Rack for 2” (5 cm) Boxes, 28 Cu. Ft. — 97059-186 270.14Storage Rack for 3” (7.6 cm) Boxes, 28 Cu. Ft. — 97059-190 211.08Sliding Drawer Rack for 2” (5 cm) Boxes, 22 & 25 Cu. Ft. — 414004-222 359.63Sliding Drawer Rack for 3” (7.6 cm) Boxes, 22 & 25 Cu. Ft. — 414004-224 359.63Sliding Drawer Rack for 2” (5 cm) Boxes, 28 Cu. Ft. — 97059-188 297.92Sliding Drawer Rack for 3” (7.6 cm) Boxes, 28 Cu. Ft. — 97059-192 250.32Cardboard Freezer Box, 2” (5 cm) with 81-cell divider — 82007-162 5.95Cardboard Freezer Box, 3” (7.6 cm) without divider — 82007-144 6.03Fiberboard Freezer Box, 81-cell divider — 82021-126 12.08
7
Wall Material,
Exterior: Coated Cold Rolled Steel
Interior: Coated Zinc Cold Rolled Steel
Inner Doors 4, Aluminum Framed PS Board
Shelves Adjustable Stainless Shelves
Testing Porthole One Located on Back Wall -1" (25.8 mm) dia.
Insulation Vacuum Insulated with Polyurethane Foam (Non-CFC)
Compressors,
High/Low Stage: Hermetically-Sealed, 1 HP
Condenser,
High Stage: Finned Coil
Low Stage: Tube-in-Tube Heat Exchanger
Evaporator Copper Tube
Refrigerant Mixed
Temperature,
Range: -10 to -86oC
Ambient: 10 to 32oC
Average Uniformity 6o
Vent Port/Plunger Yes
Temperature,
Controller: Microprocessor
Display: Digital, LED
Sensor: RTD Pt 100 ohms
Communication Package RS232 (RS485 Optional)
Chart Recorder 7-Day Record on 6" Paper
Alarms, Audible/Visible High, Low, and Ambient Temperature
Power Outage
Dirty Condenser
Battery
Voltage
Remote Alarm Terminals Max. Load: 30V (DC) at 2A
CO2 and LN2 Backup System Field Installed (call 888.793.2300)
Battery Backup 12V (DC), Automatically Rechargeable
Refrigeration System CFC/HCFC-Free
Sound Abatement Standard
Voltage Boost Internal
Regulatory Approvals UL/cUL 61010
Electrical Data
Model CapacitySingle Phase AC Power
Fuse/ Breaker
Rated Current
Rated Frequency
Efficiency (Kw/H/Day)
NEMA Plug
Heat Rejection (W) @32°C
Pull Down (hours)
414005-089 17 Cu. Ft. (481L) 120V/60Hz 20A/1 18 60 18.6 5-20P 1150 6414005-090 17 Cu. Ft. (481L) 220V/60Hz 15A/1 9 60 18 6-15P 1000 6414005-088 22 Cu. Ft. (627L) 115V, 60Hz 20A/1 18 60 18.2 5-20P 1200 6.3414005-087 22 Cu. Ft. (627L) 208/230V, 60Hz 15A/1 9 60 19.7 6-15P 1200 6.3414004-216 25.4 Cu. Ft. (718L) 208/230V, 60Hz 15A/1 9 60 19.7 6-15P 1200 6.5414004-658 28.6 Cu. Ft. (809L) 208/230V, 60Hz 15A/1 9 60 23 6-15P 1200 8
Specifications
ModelInterior Dimensions, WxDxH cm(in.)
Exterior Dimensions, WxDxH cm (in.)
2" Boxes/ Unit
3" Boxes/ Unit
2" Racks/ Unit
Vial Capacity
Inner Doors
Net Weight kg (lbs)
414005-08959 x 63D x 131 (23
7/32 x 24 13/16 x 51
19/32")94.5 x 90 x 198 (37
7/32 x 35 7/16 x 77
31/32")320 192 16 25,920 4 290 (640)
414005-09059 x 63 x 131 (23
7/32 x 24 13/16 x 51
19/32")94.5 x 90 x 198 (37
7/32 x 35 7/16 x 77
31/32")320 192 16 25,920 4 290 (640)
414005-08876 x 63 x 131 (29
7/8 x 24 3/4 x 51
1/4)103.5 x 90 x 198 (40
11/16 x 35 3/8 x 77
7/8)400 240 20 32,400 4 301 (664)
414005-08776 x 63 x 131 (29
7/8 x 24 3/4 x 51
1/4)103.5 x 90 x 198 (40
11/16 x 35 3/8 x 77
7/8)400 240 20 32,400 4 301 (664)
414004-21687 x 63 x 131 (34
5/16 x 28 x 51 1/4)
114.5 x 90 x 198 (45
1/8 x 35 3/8 x 77
7/8)480 288 24 38,880 4 350 (771)
414004-65887 x 71 x 131 (34
5/16 x 28 x 51 1/4)
114.5 x 98 x 198 (45
1/8 x 38 1/4 x 77
7/8)600 360 24 48,600 4 380 (837)
G
6-15P6-15R5-20R 5-20P
125V 250V
are standard, creating four compartments that can be subdivided with adjustable interior shelves. A patented lock design permits one-handed operation. Freezers are equipped with an internal voltage regulator and voltage compensation system to ensure a longer compressor life. Refrigeration system features well-balanced cascade technology powered with low-temperature rated specialty compressors. A built-in chart recorder is standard. Validation services, both installation and operational qualification, available upon request. Please call 1.888.793.2300 to schedule.
Technical Product Support:Our team is available to answer questions Monday through Friday, 8:30am to 4:30pm (EST) Email: [email protected] Phone: 1.888.VWR.LINE (1.888.897.5463) web: vwr.com/tps
Warranty Services: Email: [email protected] Phone: 888.793.2300 Validation - Calibration - Asset ManagementVWRCATALYST Equipment and Instrument Services offers full validation services (IQ, OQ, PQ) on all makes and models of equipment including the VWR Collection equipment in this brochure. VWRCATALYST’s validation services offer GxP compliant deliverables and custom built protocols executed with world class technicians. Ask your VWR Sales Representative for information on bundling our validation service with your equipment purchase today. In addition, the VWRCATALYST team offers the same expertise in calibration, preventive maintenance, and asset management services. Find us on the web at vwr.com (select “services”) or call us today at 1.888.793.2300 to learn more.
Power ing Produc t iv i t y. Del iver ing Results .
1012 Lit. No. POD 93138REV