Download - Wastewater Parameter Determination
![Page 1: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/1.jpg)
Md. Shah Paran
BTX-110300161
![Page 2: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/2.jpg)
Presentation on Wastewater Characterization
Presented by
Supervisor Md. Tanjim Hossain Lecturer & Co-ordinator Dept. of Textile Engineering
ID Name Remark110300161 Md Shah Paran120100079 Abdul Waras
![Page 3: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/3.jpg)
Wastewater CharacterizationThe wastewater characterized by1) pH Scale2) Total Suspended Solid (TSS)3) Total Dissolved Solid (TDS)4) Dissolved Oxygen (DO)5) Chemical Oxygen Demand (COD)6) Biological Oxygen Demand (BOD)
![Page 4: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/4.jpg)
The acceptable range for environment of this parameter
Parameter RangepH 6-9TSS Less then 150 ppmTDS Less than 2100 ppmDO 4.5-8
COD Less than 200 ppmBOD Less than 50 ppm
![Page 5: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/5.jpg)
pH
pH is the abbreviation of pondus hydrogen pH = -log [H+]
[H+] is in molar concentration
![Page 6: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/6.jpg)
pH measurement is required--To produce products with defined properties-To protect equipment-For research and development
![Page 7: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/7.jpg)
pH of a material is determined by
Electrochemical method Depends on hydrogen activity in the solution It consists of two electrodes1. Measuring electrode 2. Reference electrode
![Page 8: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/8.jpg)
Measuring electrode (Glass electrode)
Dependent on hydrogen activity Glass membrane is sensitive to H+ ions
![Page 9: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/9.jpg)
Reference electrode
• insensitive to the H+ ions in the solution
• most widely used is thesilver/silver chloride electrode• another commonly usedreference electrode is thecalomel electrode
![Page 10: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/10.jpg)
Other methods
Optical Methods -Indicator papers ISFET electrode
![Page 11: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/11.jpg)
Total Suspended Solids (TSS)
The solids retained on a filter paper of pore size 2.0 µm or smaller, during the filtration of the sample water
Total Suspended Solids are the amount of filterable solids in a water sample. Samples are filtered through a glass fiber filter. The filters are dried and weighed to determine total suspended solids in mg/L.
![Page 12: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/12.jpg)
Determination of TSS Prepare a 0.45 micron filter using wash-dry-cool cycle Seat filter with DI water prior to filtration Pippet a measured volume into filtration apparatus
from stirred sample Wash filter with 3 x 10 mL washings DI water Apply suction for 3 minutes after washing Transfer to aluminum dish for support Dry in the oven at 103-105 °C overnight (should be 1
h) Place in a desiccator to cool to room temperature,
reweigh to the nearest 0.1 mg Calculate TSS in mg/L
![Page 13: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/13.jpg)
CalculationsTotal suspended solids (TSS) :The total suspended solids (TSS) is given by
thefollowing formula:mg/L Total suspended solids = ( A-B) × 1000 / ml
sampleWhere,A = weight of filter disk with dried residue B = weight of filter disk only
![Page 14: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/14.jpg)
Total Dissolved Solids (TDS)
The solids that pass through the filter paper during the filtration of sample water
Total Dissolved Solids are those solids (inorganic + organic) that pass through a filter of 2.0 μm or smaller. They are said to be non-filterable. After filtration the filtrate (liquid) is dried and the remaining residue is weighed and calculated as mg/L of Total Dissolved Solids
![Page 15: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/15.jpg)
Determination of TDS1. Dry a clean dry beaker at 103-105 °C for at least 1
hour2. Desiccate until cool and weigh to nearest 0.1 mg3. Filter 50.0 mL through a 0.45 μm filter paper into
clean dry beaker using technique described above4. Heat the sample to just below boiling and reduce
the volume to 10 mL5. Allow the beaker to cool and dry in the oven at 103-
105 °C overnight6. Remove the beaker and place in a desicator to cool
to room temperature, reweigh to the nearest 0.1 mg7. Calculate TDS in mg/L
![Page 16: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/16.jpg)
CalculationsTotal Dissolved solids (TDS): The total dissolved solids are given by the formula: mg/L Total dissolved solids = ( A-B) × 1000 / ml
sampleWhere; A = weight of dried residue + dish weight (mg)B = weight of dish (mg)
![Page 17: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/17.jpg)
Abdul Waras
BTX-120100079
![Page 18: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/18.jpg)
![Page 19: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/19.jpg)
Dissolved Oxygen (DO) Dissolved Oxygen is the amount of gaseous
oxygen (O2) dissolved in the water. Oxygen enters the water by direct absorption from the atmosphere, by rapid movement, or as a waste product of plant photosynthesis. Water temperature and the volume of moving water can affect dissolved oxygen levels. Oxygen dissolves easier in cooler water than warmer water.
![Page 20: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/20.jpg)
Adequate dissolved oxygen is important for good water quality and necessary to all forms of life. Dissolved oxygen levels that drop below 5.0 mg/L cause stress to aquatic life. Lower concentrations cause greater stress. Oxygen levels that go below 1-2 mg/L for a few hours may result in large fish kills.
![Page 21: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/21.jpg)
Determination of DOMaterials: 300.0 ml BOD bottles or SOLA (glass)
bottles with cap 250.0 ml graduated cylinder 500.0 ml Erlenmeyer flasks 1.0 ml Pipettes Rubber aspirator Titration set-up
![Page 22: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/22.jpg)
Procedure:
Collect samples in a 300 mL SOLA bottle Add 2ml of manganous sulfate solution Add 2 ml of alkaline-iodide-sodium azide
solution Shake the bottle by inverting several
times Allow solution to settle Add 2ml of conc. sulfuric acid Shake well until precipitate is dissolved
![Page 23: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/23.jpg)
Titration Procedure:
Pour 200ml of sample from the SOLA bottle into an Erlenmeyer flask
If the solution is reddish-brown in color, titrate with 0.0250 N sodium thiosulfate
If the solution has no reddish-brown color, or is only slightly colored,
add a small quantity (approx. 1 mL) of starch
indicator.
![Page 24: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/24.jpg)
Biochemical Oxygen Demand (BOD)
BOD is the amount of dissolved oxygen needed by aerobic biological organism in a body of water to breakdown organic material present in a given water sample at certain temperature over a specific time period (5 days).
![Page 25: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/25.jpg)
HYPOXIA: When dissolve oxygen content below 3.0 mg/L. Many Species move elsewhere and immobile species may die.
ANOXIA: When dissolve oxygen content below 0.5 mg/L. All aerobic species will die.
![Page 26: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/26.jpg)
Determination of BOD
A. DilutionDilution Factor: The dilution factor, DF, is the ratio of
the final volume to the volume of sample therein. (e.g., for the bottle method, the volume of the BOD bottle, usually 300 mL; for the graduated bottle, usually 300 mL; for the graduated cylinder method, the volume of the cylinder, usually 1000 mL).
DF for the bottle method = {Volume of Diluted Mixture÷Volume of Sample in Mixture
![Page 27: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/27.jpg)
B. DO fixation 1. Slowly siphon three portions of aerated dilution water into
three separate BOD bottles. Avoid adding atmospheric O2to dilution water.
2. To two of the three BOD bottles, add 1 2.To two of the three BOD bottles, add 1 ml MnS04solution, followed by 1 ml alkali-iodide-azide reagent. Submerge pipette tips in sample when adding reagents. Rinse tips well between uses.
3. Stopper carefully to exclude air bubbles; mix by inverting bottle several times.
4.When precipitate has settled to about half the bottle volume, carefully half the bottle volume, carefully remove the stopper and add 1.0 ml conc. sulfuric acid. Re-stopper and mix by gentle inversion until the iodine is uniformly distributed throughout the bottle.
![Page 28: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/28.jpg)
C. DO Measurement5. Transfer 203 ml of sample into conical flask and
titrate with 0.0250N sodium thiosulfate to a pale straw color.
6. Add 1-2 ml of starch solution and continue to titrate to first disappearance continue to titrate to first disappearance of the blue color. (200 ml of original dilution water is equal to 203 ml of dilution water plus reagents).
7. Determine the initial concentration of dissolved oxygen in one bottle of the mixture of sample and dilution water (DO), and in one of the water (DOinitial), and in one of the bottles containing only dilution water.
![Page 29: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/29.jpg)
8. Place the other bottles in the incubator9. Incubate the blank dilution water and the diluted
samples for 5 days in the dark at 20 °C. 10. After 5 days, remove the bottles, fix the DO
and measure the DO (DOfinal) DO and measure the DO (DOfinal)
11. Calculate BOD5 BOD5(mg/L) = {DOinitial(mg/L) of first bottle -
DOfinal(mg/L) of second bottle} x dilution factor
![Page 30: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/30.jpg)
Chemical Oxygen DemandCOD is the total amount of oxygen required to
chemically oxidize the bio degradable and non-biodegradable organic matter.
It is expressed in milligrams per liter (mg/L) also referred to as ppm (parts per million), which indicates the mass of oxygen consumed per liter of solution.
![Page 31: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/31.jpg)
Determination of COD Water sample is refluxed in strong acidic solution
with a known excess amount of potassium dichromate.
After digestion, the remaining unreduced K2Cr2O7 is titrated with Ferrous Ammonium Sulfate (FAS)to determine K2Cr2O7 consumed.
This gives us the oxidizable organic matter in terms of oxygen equivalent.
![Page 32: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/32.jpg)
Procedure1. Wash 300 ml round bottom refluxing flask.2. In refluxing flask put one spatula of HgSO4 + 10 ml
sample + 5ml K2Cr2O7 + 15 ml concentrated H2SO4.3. Add small amount of silver sulphate.4. Shake well and reflux for 2 hr.5. Cool and add little amount of distilled water to the
flask through the condenser6. Titrate the solution in the flask against FAS using
Ferrion indicator7. End point green color to reddish brown
![Page 33: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/33.jpg)
For blank, add 10 ml distilled water instead of sample. Rest of the procedure is the same.
CALCULATIONS The COD in mg/l is determined by the formula,
COD mg/l = (A-B)xNx8000ml sample taken
A = ml of FAS required for blank. B = ml of FAS requires for sample.
![Page 34: Wastewater Parameter Determination](https://reader035.vdocument.in/reader035/viewer/2022070519/58edde7d1a28abae668b46f7/html5/thumbnails/34.jpg)
Thank YouFor Your
Kind Attention