WATER HEATERS & STORAGE TANKS
2019PRODUCT GUIDE
ver. 1.0ver. 1.12021
WATER HEATERS & STORAGE TANKS
08101214161820222426283032343638404244
WATER HEATERS & STORAGE TANKS11.11 KBS SINGLE COIL WATER HEATER
11.12 KBS-B BASIC SINGLE COIL WATER HEATER
11.13 KBD DOUBLE COIL WATER HEATER
11.14 KBD-B BASIC DOUBLE COIL WATER HEATER
11.15 KXS SINGLE ROW COIL HEAT PUMP WATER HEATER
11.16 KXD DOUBLE ROW COIL HEAT PUMP WATER HEATER
11.17 KSH HYBRID WATER HEATER
11.18 KCS SINGLE COPPER COIL WATER HEATER
11.19 KCD DOUBLE COPPER COIL WATER HEATER
11.23 KEB ELECTRIC WATER HEATER
51.11 KAT ENAMELLED ACCUMULATION TANK
101.12 KCB-S SINGLE COIL COMBI BUFFER TANK
51.12 KGA GALVANIZED ACCUMULATION TANK
101.13 KBT-B BUFFER TANK
101.14 KBT-S SINGLE COIL BUFFER TANK
101.15 KBT-D DOUBLE COIL BUFFER TANK
101.16 KBT-CB HYDRAULIC BALANCING BUFFER TANK
101.17 KBT-C BUFFER TANK WITH BAFFLE PLATE
911 KPG AUTOMATIC PUMP CONTROLLED EXPANSION SYSTEM
CONTENT
2
4 5
Our VisionIn the light of the principles of honesty and trust, to provide human and environment-oriented products and services, to enlarge the business opportunities it has developed, and to be one of the top 5 companies in the world in the industry.
Our MissionWith its expert and dynamic team, innovative spirit and strong business partners, spreading our quality to the World, to create added value and difference by enlarging the business models.
About UsKodsan entered the heating industry with solid fuel boiler production when Mehmet Namık Kodaman founded the company in 1984, Ankara. It has become a leading company with its innovations, success, and people-oriented business strategies. It has grown, developed, and renewed considerably with the strength of over 35 years of experience.
As Turkey’s first and largest enamel coated water heater manufacturer, Kodsan increases its recognition in early 2000, in Turkey and surrounding countries. Kodsan manufactures enamel/ non-enamel covered water heaters, heat interface units, automatic pump controlled expansion systems, separators and filters, installment protection equipments.
Additionally, with its extensive technical service network, Kodsan provides service for energy consumption management and heat meter inspection.
Our AchievementsKodsan shines out with its advanced technology, high efficiency products and flexible production capability which can quickly adapt to the customer demands. However among these specialities, Kodsan prioritizes human health as well as the environment. Following this principle, all production processes and products are appropriate to the Europe Environment and Human Health Regulations(Reach and Rosh). For example;
• WRAS certification for the used enamel as well as for all the materials and products that contacts the drinkable water.
• Kodsan manufactures specially designed products that avoid bacteria growth such as legionella which causes the legionnaire disease.
• Kodsan is one of the limited companies that has a waste water treatment facility.
• Raw material which does not include heavy metals and with low carbon footprint are being used during production.
• Maximum sensitivity shown for recycling through all production processes.
Milestones
Founded in Ankara as a solid fuel boiler manufacturer on 400m2.
First export sales is realized.
Company reached 12.000m² closed area and 16.500m² area in total.
The number of export sales exceeded 35 countries.
The number of Export sales exceed 50 countries.
The production lines and designs of the company have been purchased, and the Heat Interface Unit manufacturing has started.
started.
Company reached 20.000m² closed area and 24.500m² area in total.
Distribution for TR market with
Enameled water heater manufacturing started.
Started to the construction of 2000m2 area in Sincan Organized Industrial Zone.
Separator production line was established.
Boiler manufaturing ended.
Design Center is approved by government.
started.
Partnership with
KODSAN
Azerbaijan, Canada, Denmark, France, Germany, Greece, Holland, Iraq, Israel, Italy, Kenya, Norway, Portugal, Qatar, Republic of South Africa, Russia, Saudi Arabia, South Korea, Spain, Sweden, Thailand, United Arab Emirates, United Kingdom, Uruguay
Main Export Countries
1984 2002 20171998 2013 20191992 2004 20182000 20162015 2020
Kodsan supplies high quality spare parts and complementary items with
competitive offers.
It is possible for you to extend your product’s warranty by using Kodsan’s
modified safety kit alternatives.
SAVETIME & COST
UP TO10 YEARS WARRANTY
ONLINETECH SUPPORT
LIFELONGDURABILITY
Our top priority is customer satisfaction. Now Kodsan has an online technical
support service. You may benefit from maintenance tracking system option.
Magnesium or current anodes are the main protection elements for Kodsan water heaters. With the right periodic maintenance you may extend your
product’s life.
ABOUT SAFETY EQUIPMENTS
Max. 8 bar full-lift safety valve must be used at the cold water inlet of all enamel coated water heaters.The expansion tank should be selected by consideration of total volume of water heaters used at the system. Water heaters will be out of warranty conditions in case of not usage / failure or incorrect installation of the safety equipments.
DO NOT FORGET PERIODIC MAINTENANCE
Be sure to replace the magnesium anode rod for periodic maintenance at least once a year.The anode rod is located on the upper center of the tank. For detailed information, check the operating and installation manual.
6 7
11.11 KBS SINGLE COIL WATER HEATER
INSTALLATION DIAGRAM
8
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.
N9
ØD
N33 N8
N7
N6
N5N4
N2
H
N1
Volume 100L-3000L
Maximum Heating Power 272 kWh
Maximum Solar Collector Area 87 m2
Heat Exchanger Maximum Operating Temperature 110˚C
Heat Exchanger Maximum Operating Pressure 10 bar
Domestic Hot Water Maximum Operating Temperature 95˚C
Domestic Hot Water Maximum Operating Pressure 10 bar
Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
N31
Capacity
Insulation Type & Thickness
Diameter
Height
Cleaning & Control Flange Diameter
Electric Heater Connection
Thermometer / Steel Sensor Tube ConnectionsDomestic Cold Water Inlet ConnectionHeat Exchanger (Coil) Inlet/Outlet Connections
Circulation Return Connection
Domestic Hot Water Outlet Connection
Magnesium Anode Connection
Blind Connection
Gross Weight
Tilt Height
V
i
ØD
H
N1
N2
N3
N4
N5-N6
N7
N8
N9
N10
G
R
lt
mm
mm
mm
inch
inch
inch/mm
inch
inch
inch
inch
inch
inch
kg
mm
100
PU/50
480
1110
Ø100
1½”
½”/ 9
¾”
1”
¾”
¾”
1¼”
1¼”
52
1210
160
PU/50
580
1135
Ø100
1½”
½”/ 9
¾”
1¼”
¾”
¾”
1¼”
1¼”
75
1275
200
PU/50
580
1340
Ø100
1½”
½”/ 9
¾”
1¼”
¾”
¾”
1¼”
1¼”
88
1460
300
PU/50
580
1860
Ø100
1½”
½”/ 9
¾”
1¼”
¾”
¾”
1¼”
1¼”
98
1950
500
PU/50
740
1845
Ø100
1½”
½”/ 9
1”
1¼”
¾”
1”
1¼”
1¼”
150
1990
800
SPU/80
910
2110
Ø125
2”
½”/ 9
1¼”
1¼”
1¼”
1¼”
1¼”
1¼”
245
2300
1000
SPU/80
1010
2070
Ø125
2”
½”/ 9
1¼”
1¼”
1¼”
1¼”
1¼”
1¼”
260
2305
1500
SPU/80
1120
2375
Ø125
2”
½”/ 9
1¼”
1¼”
1¼”
1¼”
1¼”
2”
360
2625
2000
SPU/80
1310
2280
Ø125
2”
½”/ 9
1¼”
1¼”
1¼”
1¼”
1¼”
2”
455
2630
2500
SPU/80
1460
2160
Ø125
2”
½”/ 9
1½”
1½”
1½”
1½”
1¼”
2”
650
2610
3000
SPU/80
1460
2580
Ø125
2”
½”/ 9
1½”
1½”
1½”
1½”
1¼”
2”
735
2965
Code Unit 11.11.11 11.11.13 11.11.14 11.11.16 11.11.18 11.11.20 11.11.21 11.11.22 11.11.23 11.11.24 11.11.25
STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Steel Sensor Tube STD/Ø9 mm 2 pieces
STD/Ø9 mm 2 pieces
STD/Ø9 mm 2 pieces
STD/Ø9 mm 2 pieces
Cleaning & Control Flange STD/Ø100 mm STD/Ø125 mm OPS/Ø400 mm
STD/Ø125 mm OPS/Ø400 mm
STD/Ø125 mm OPS/Ø400 mm
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards STD/50 mm x x x
Blueshell- Recyclable polyethylene cover that provides heat-saving xSTD x x
Vinleks- Artificial Leather STDx STD STD
Magnesium Anode STDSTD STD STD
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application) OPSx OPS OPS
Electronic Anode OPSOPS OPS OPS
Steel leg system mounted on a palette from 3 different locations STD STD-xSTD x
Circle steel leg system that provides circular floor contact x x-STDx STD
Electric Heater OPS/2”OPS/1½” OPS/2” OPS/2”
Thermometer (0°C- 120°C) STD/Ø100STD/Ø63 STD/Ø100 STD/Ø100
Soft PU- 15 kg/m3 soft polyurethane x STD / 80mm STD / 80mm STD / 80mm
Soft PU- 26 kg/m3 flame retardant soft polyurethane x OPS / 80mm OPS / 80mm OPS / 80mm
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards x OPS / 80mm OPS / 80mm
OPS / 100mm OPS / 80mm
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
100L-500L 800L-1000L 1500L-2000L 2500L-3000L
The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection. KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
9
N10
N32
Domestic Cold Water
Domestic Hot Water
Heating Water Inlet
Heating Water Return
11.12 KBS-B BASIC SINGLE COIL WATER HEATER
INSTALLATION DIAGRAM
10
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.
N9
ØD
N32 N8
N7
N6
N5N4
N2
H
N1
Volume 100L-500L
Maximum Heating Power 66 kWh
Maximum Solar Collector Area 19 m2
Heat Exchanger Maximum Operating Temperature 110˚C
Heat Exchanger Maximum Operating Pressure 10 bar
Domestic Hot Water Maximum Operating Temperature 95˚C
Domestic Hot Water Maximum Operating Pressure 6bar / 10 bar
Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
N31
Capacity
Insulation Type & Thickness
Diameter
Height
Cleaning & Control Flange Diameter
Electric Heater Connection
Thermometer / Steel Sensor Tube ConnectionsDomestic Cold Water Inlet ConnectionHeat Exchanger (Coil) Inlet/Outlet Connections
Circulation Return Connection
Domestic Hot Water Outlet Connection
Magnesium Anode Connection
Blind Connection
Gross Weight
Tilt Height
V
i
ØD
H
N1
N2
N3
N4
N5-N6
N7
N8
N9
N10
G
R
lt
mm
mm
mm
inch
inch
inch/mm
inch
inch
inch
inch
inch
inch
kg
mm
100
PU/50
480
1110
Ø100
1½”
½”/ 9
¾”
1”
¾”
¾”
1¼”
1¼”
52
1210
160
PU/50
580
1135
Ø100
1½”
½”/ 9
¾”
1¼”
¾”
¾”
1¼”
1¼”
68
1275
200
PU/50
580
1340
Ø100
1½”
½”/ 9
¾”
1¼”
¾”
¾”
1¼”
1¼”
76
1460
300
PU/50
580
1860
Ø100
1½”
½”/ 9
1”
1¼”
¾”
1”
1¼”
1¼”
98
1950
500
PU/50
740
1845
Ø100
1½”
½”/ 9
1”
1¼”
¾”
1”
1¼”
1¼”
135
1990
Code Unit 11.12.11 11.12.13 11.12.14 11.12.16 11.12.18
STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Steel Sensor Tube
Cleaning & Control Flange
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Magnesium Anode
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)
Electronic Anode
Steel leg system mounted on a palette from 3 different locations
Circle steel leg system that provides circular floor contact
Electric Heater
Thermometer (0°C- 120°C)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
STD/Ø9 mm 1 pieces
STD/Ø100 mm
STD/50 mm
STD
x
STD
x
OPS
STD
x
OPS/1½”
STD/Ø63
x
x
x
100L-500L
The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection. KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
11
N10
Domestic Cold Water
Domestic Hot Water
Heating Water Inlet
Heating Water Return
11.13 KBD DOUBLE COIL WATER HEATER
12
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
N11
ØD
N33
N32
N8
N9
N10
N7
N6
N5N4
N12
N2
H
N1
N31
Capacity
Insulation Type & Thickness
Diameter
Height
Cleaning & Control Flange Diameter
Electric Heater Connection
Thermometer / Steel Sensor Tube ConnectionsDomestic Cold Water Inlet ConnectionLower Heat Exchanger (Coil) Inlet/Outlet Connections Upper Heat Exchanger (Coil) Inlet/Outlet Connections
Circulation Return Connection
Domestic Hot Water Outlet Connection
Magnesium Anode Connection
Blind Connection
Gross Weight
Tilt Height
V
i
ØD
H
N1
N2
N3
N4
N5-N6
N7-N9
N8
N10
N11
N12
G
R
lt
mm
mm
mm
inch
inch
inch/mm
inch
inch
inch
inch
inch
inch
inch
kg
mm
160
PU/50
580
1135
Ø100
1½”
½”/ 9
¾”
1¼”
1¼”
¾”
¾”
1¼”
1¼”
82
1275
200
PU/50
580
1340
Ø100
1½”
½”/ 9
¾”
1¼”
1¼”
¾”
¾”
1¼”
1¼”
91
1460
300
PU/50
580
1860
Ø100
1½”
½”/ 9
¾”
1¼”
1¼”
¾”
¾”
1¼”
1¼”
104
1950
500
PU/50
740
1845
Ø100
1½”
½”/ 9
1”
1¼”
1¼”
¾”
1”
1¼”
1¼”
178
1990
800
SPU/80
910
2110
Ø125
2”
½”/ 9
1¼”
1¼”
1¼”
1¼”
1¼”
1¼”
1¼”
275
2300
1000
SPU/80
1010
2070
Ø125
2”
½”/ 9
1¼”
1¼”
1¼”
1¼”
1¼”
1¼”
1¼”
290
2305
1500
SPU/80
1120
2375
Ø125
2”
½”/ 9
1¼”
1¼”
1¼”
1¼”
1¼”
1¼”
2”
390
2625
2000
SPU/80
1310
2280
Ø125
2”
½”/ 9
1¼”
1¼”
1¼”
1¼”
1¼”
1¼”
2”
500
2630
2500
SPU/80
1460
2160
Ø125
2”
½”/ 9
1½”
1½”
1½”
1½”
1½”
1¼”
2”
720
2610
3000
SPU/80
1460
2580
Ø125
2”
½”/ 9
1½”
1½”
1½”
1½”
1½”
1¼”
2”
805
2965
Code Unit 11.13.13 11.13.14 11.13.16 11.13.18 11.13.20 11.13.21 11.13.22 11.13.23 11.13.24 11.13.25
STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Steel Sensor Tube STD/Ø9 mm 2 pieces
STD/Ø9 mm 2 pieces
STD/Ø9 mm 2 pieces
STD/Ø9 mm 2 pieces
Cleaning & Control Flange STD/Ø100 mm STD/Ø125 mm OPS/Ø400 mm
STD/Ø125 mm OPS/Ø400 mm
STD/Ø125 mm OPS/Ø400 mm
STD/50 mm x x x
xSTD x x
STDx STD STD
Magnesium Anode STDSTD STD STD
OPSx OPS OPS
Electronic Anode OPSOPS OPS OPS
Steel leg system mounted on a palette from 3 different locations STD STD-xSTD x
Circle steel leg system that provides circular floor contact x x-STDx STD
Electric Heater OPS/2”OPS/1½” OPS/2” OPS/2”
Thermometer (0°C- 120°C) STD/Ø100STD/Ø63 STD/Ø100 STD/Ø100
x STD / 80mm STD / 80mm STD / 80mm
x OPS / 80mm OPS / 80mm OPS / 80mm
x OPS / 80mm OPS / 80mm OPS / 100mm OPS / 80mm
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
160L-500L 800L-1000L 1500L-2000L 2500L-3000L
The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties. 13
Volume 160L-3000L
Upper Heat Exchanger Maximum Heating Power 141 kWh
Lower Heat Exchanger Maximum Heating Power 272 kWh
Maximum Solar Collector Area 87 m2
Heat Exchanger Maximum Operating Temperature 110˚C
Heat Exchanger Maximum Operating Pressure 10 bar
Domestic Hot Water Maximum Operating Temperature 95˚C
Domestic Hot Water Maximum Operating Pressure 10 bar
Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.
Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
INSTALLATION DIAGRAM
Domestic Cold Water
Domestic Hot Water
Heating Water Inlet
Heating Water Return
11.14 KBD-B BASIC DOUBLE COIL WATER HEATER
14
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
N11
ØD
N33
N32
N8
N9
N10
N7
N6
N5N4
N12
N2
H
N1
N31
Capacity
Insulation Type & Thickness
Diameter
Height
Cleaning & Control Flange Diameter
Electric Heater Connection
Thermometer / Steel Sensor Tube ConnectionsDomestic Cold Water Inlet ConnectionLower Heat Exchanger (Coil) Inlet/Outlet Connections Upper Heat Exchanger (Coil) Inlet/Outlet Connections
Circulation Return Connection
Domestic Hot Water Outlet Connection
Magnesium Anode Connection
Blind Connection
Gross Weight
Tilt Height
V
i
ØD
H
N1
N2
N3
N4
N5-N6
N7-N9
N8
N10
N11
N12
G
R
Code
lt
mm
mm
mm
inch
inch
inch/mm
inch
inch
inch
inch
inch
inch
inch
kg
mm
Unit
160
PU/50
580
1135
Ø100
1½”
½”/ 9
¾”
1¼”
1¼”
¾”
¾”
1¼”
1¼”
80
1275
11.14.13
200
PU/50
580
1340
Ø100
1½”
½”/ 9
¾”
1¼”
1¼”
¾”
¾”
1¼”
1¼”
87
1460
11.14.14
300
PU/50
580
1860
Ø100
1½”
½”/ 9
1”
1¼”
1¼”
¾”
1”
1¼”
1¼”
104
1950
11.14.16
500
PU/50
740
1845
Ø100
1½”
½”/ 9
1”
1¼”
1¼”
¾”
1”
1¼”
1¼”
155
1990
11.14.18
STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Steel Sensor Tube
Cleaning & Control Flange
Magnesium Anode
Electronic Anode
Steel leg system mounted on a palette from 3 different locations
Circle steel leg system that provides circular floor contact
Electric Heater
Thermometer (0°C- 120°C)
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
STD/Ø9 mm 2 pieces
STD/Ø100 mm
STD/50 mm
STD
x
STD
x
OPS
STD
x
OPS/1½”
STD/Ø63
x
x
x
160L-500L
The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties. 15
Volume 160L-500L
Upper Heat Exchanger Maximum Heating Power 41 kWh
Lower Heat Exchanger Maximum Heating Power 55 kWh
Maximum Solar Collector Area 29 m2
Heat Exchanger Maximum Operating Temperature 110˚C
Heat Exchanger Maximum Operating Pressure 10 bar
Domestic Hot Water Maximum Operating Temperature 95˚C
Domestic Hot Water Maximum Operating Pressure 6 bar / 10 bar
Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.
Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
INSTALLATION DIAGRAM
Domestic Cold Water
Domestic Hot Water
Heating Water Inlet
Heating Water Return
11.15 KXS SINGLE ROW COIL HEAT PUMP WATER HEATER
16
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
N9
ØD
N3 N8
N7
N6
N5N4
N10
H
(N2)N1
STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Steel Sensor Tube
Cleaning & Control Flange
Magnesium Anode
Electronic Anode
Steel leg system mounted on a palette from 3 different locations
Circle steel leg system that provides circular floor contact
Electric Heater
Thermometer (0°C- 120°C)
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
STD/Ø9 mm 2 pieces
STD/Ø100 mm
STD/50 mm
STD
x
STD
x
OPS
STD
x
OPS/1½”
STD/Ø63
x
x
x
160L-500L
17
Capacity
Insulation Type & Thickness
Diameter
Height
Cleaning & Control Flange Diameter
Electric Heater Connection
Thermometer / Steel Sensor Tube ConnectionsDomestic Cold Water Inlet ConnectionHeat Exchanger (Coil) Inlet/Outlet Connections
Circulation Return Connection
Domestic Hot Water Outlet Connection
Magnesium Anode Connection
Blind Connection
Gross Weight
Tilt Height
V
i
ØD
H
N1
N2
N3
N4
N5-N7
N6
N8
N9
N10
G
R
lt
mm
mm
mm
inch
inch
inch/mm
inch
inch
inch
inch
inch
inch
kg
mm
160
PU/50
580
1135
Ø100
1½”
½”/ 9
¾”
1”
¾”
¾”
1¼”
1¼”
80
1275
200
PU/50
580
1340
Ø100
1½”
½”/ 9
¾”
1”
¾”
¾”
1¼”
1¼”
92
1460
300
PU/50
700
1220
Ø100
1½”
½”/ 9
1”
1”
1”
1”
1¼”
1¼”
120
1410
500
PU/50
740
1845
Ø100
1½”
½”/ 9
1”
1”
1”
1”
1¼”
1¼”
165
1990
Code Unit 11.15.13 11.15.14 11.15.16 11.15.18
The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
Volume 160L-500L
Maximum Heating Power 251 kWh
Maximum Solar Collector Area 54 m2
Heat Exchanger Maximum Operating Temperature 110˚C
Heat Exchanger Maximum Operating Pressure 10 bar
Domestic Hot Water Maximum Operating Temperature 95˚C
Domestic Hot Water Maximum Operating Pressure 10 bar
Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.
Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
INSTALLATION DIAGRAM
Domestic Cold Water
Domestic Hot Water
11.16 KXD DOUBLE ROW COIL HEAT PUMP WATER HEATER
18
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
N9
ØD
N3 N8
N7
N6
N5N4
N10
H
(N2)N1
STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Steel Sensor Tube
Cleaning & Control Flange
Magnesium Anode
Electronic Anode
Steel leg system mounted on a palette from 3 different locations
Circle steel leg system that provides circular floor contact
Electric Heater
Thermometer (0°C- 120°C)
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
STD/Ø9 mm 2 pieces
STD/Ø100 mm
STD/50 mm
STD
x
STD
x
OPS
STD
x
OPS/1½”
STD/Ø63
x
x
x
160L-500L
19
Capacity
Insulation Type & Thickness
Diameter
Height
Cleaning & Control Flange Diameter
Electric Heater Connection
Thermometer / Steel Sensor Tube ConnectionsDomestic Cold Water Inlet ConnectionHeat Exchanger (Coil) Inlet/Outlet Connections
Circulation Return Connection
Domestic Hot Water Outlet Connection
Magnesium Anode Connection
Blind Connection
Gross Weight
Tilt Height
V
i
ØD
H
N1
N2
N3
N4
N5-N7
N6
N8
N9
N10
G
R
lt
mm
mm
mm
inch
inch
inch/mm
inch
inch
inch
inch
inch
inch
kg
mm
160
PU/50
580
1135
Ø100
1½”
½”/ 9
¾”
1¼”
¾”
¾”
1¼”
1¼”
95
1275
200
PU/50
580
1340
Ø100
1½”
½”/ 9
¾”
1¼”
¾”
¾”
1¼”
1¼”
113
1460
300
PU/50
700
1220
Ø100
1½”
½”/ 9
1”
1¼”
1”
1”
1¼”
1¼”
150
1410
500
PU/50
740
1845
Ø100
1½”
½”/ 9
1”
1¼”
1”
1”
1¼”
1¼”
210
1990
Code Unit 11.16.13 11.16.14 11.16.16 11.16.18
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
Volume 160L-500L
Maximum Heating Power 218 kWh
Maximum Solar Collector Area 17 m2
Heat Exchanger Maximum Operating Temperature 110˚C
Heat Exchanger Maximum Operating Pressure 10 bar
Domestic Hot Water Maximum Operating Temperature 95˚C
Domestic Hot Water Maximum Operating Pressure 10 bar
Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.
Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
N10
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
INSTALLATION DIAGRAM
Domestic Cold Water
Domestic Hot Water
11.17 KSH HYBRID WATER HEATER
20
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
N11
ØD
N3
N8
N9N10
N7
N6
N5N4
N12
H
N1
N2
STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Steel Sensor Tube
Cleaning & Control Flange
Magnesium Anode
Electronic Anode
Steel leg system mounted on a palette from 3 different locations
Circle steel leg system that provides circular floor contact
Electric Heater
Thermometer (0°C- 120°C)
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
STD/Ø9 mm 3 pieces
STD/Ø100 mm
STD/50 mm
STD
x
STD
x
OPS
STD
x
OPS/1½”
STD/Ø63
x
x
x
200L-500L
STD/Ø9 mm 3 pieces
STD/Ø125 mm
x
x
STD
STD
OPS
OPS
STD
x
OPS/2”
STD/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm
800L-1000L
21
Capacity
Insulation Type & Thickness
Diameter
Height
Cleaning & Control Flange Diameter
Electric Heater Connection
Thermometer / Steel Sensor Tube Connections
Domestic Cold Water Inlet Connection
Lower Heat Exchanger (Coil) Inlet/Outlet Connections
Upper Heat Exchanger (Coil) Inlet/Outlet Connections
Circulation Return Connection
Domestic Hot Water Outlet Connection
Magnesium Anode Connection
Blind Connection
Gross Weight
Tilt Height
V
i
ØD
H
N1
N2
N3
N4
N5-N6
N7-N9
N8
N10
N11
N12
G
R
lt
mm
mm
mm
inch
inch
inch/mm
inch
inch
inch
inch
inch
inch
inch
kg
mm
200
PU/50
580
1340
Ø100
1½”
½”/ 9
1”
1”
1¼”
1”
1”
1¼”
1¼”
113
1460
300
PU/50
580
1860
Ø100
1½”
½”/ 9
1”
1”
1¼”
1”
1”
1¼”
1¼”
156
1950
500
PU/50
740
1845
Ø100
1½”
½”/ 9
1”
1”
1¼”
1”
1”
1¼”
1¼”
165
1990
800
SPU/80
910
2110
Ø125
2”
½”/ 9
1¼”
1”
1¼”
1¼”
1¼”
1¼”
1¼”
310
2300
1000
SPU/80
1010
2200
Ø125
2”
½”/ 9
1¼”
1”
1¼”
1¼”
1¼”
1¼”
1¼”
340
2420
Code Unit 11.17.14 11.17.16 11.17.18 11.17.20 11.17.21
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
Volume 200L-1000L
Upper Heat Exchanger Maximum Heating Power 161 kWh
Lower Heat Exchanger Maximum Solar Collector Area 10 m2
Heat Exchanger Maximum Operating Temperature 110˚C
Heat Exchanger Maximum Operating Pressure 10 bar
Domestic Hot Water Maximum Operating Temperature 95˚C
Domestic Hot Water Maximum Operating Pressure 10 bar
Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.
Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
INSTALLATION DIAGRAM
Domestic Cold Water
Domestic Hot Water
11.18 KCS SINGLE COPPER COIL WATER HEATER
22
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
N8
ØD
N3
N2
N1
N6
N5
N4
N9
H
N7
N7STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Steel Sensor Tube
Cleaning & Control Flange
Magnesium Anode
Electronic Anode
Steel leg system mounted on a palette from 3 different locations
Circle steel leg system that provides circular floor contact
Electric Heater
Thermometer (0°C- 120°C)
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
STD/Ø9 mm 2 pieces
STD/Ø400 mm
x
x
STD
x
OPS
STD
STD
x
OPS/2”
STD/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm
STD/Ø9 mm 2 pieces
STD/Ø400 mm
x
x
STD
x
OPS
STD
STD-x
x-STD
OPS/2”
STD/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm OPS/100 mm
STD/Ø9 mm 2 pieces
STD/Ø400 mm-STD/Ø500 mm
x
x
STD
x
OPS
STD
x
STD
OPS/2”
STD/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm
STD/Ø9 mm 2 pieces
STD/Ø500 mm
x
x
STD
x
OPS
STD
x
STD
OPS/2”
STD/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm
800L-1000L 1500L-2000L 2500L-3000L 4000L-5000L
23
Capacity
Insulation Type & Thickness
Diameter
Height
Heat Exchanger (Serpantine) Flange Diameter
Electric Heater Connection
Thermometer / Steel Sensor Tube Connections
Domestic Cold Water Inlet Connection
Circulation Return Connection
Domestic Hot Water Outlet Connection
Heat Exchanger (Coil) Inlet/Outlet Connections
Electronic Anode Connection
Blind Connection
Gross Weight
Tilt Height
V
i
ØD
H
ØN1
N2
N3
N4
N5
N6
N7
N8
N9
G
R
lt
mm
mm
mm
mm
inch
inch/mm
inch
inch
inch
inch
inch
inch
kg
mm
800
SPU/80
910
2110
Ø400
2”
½”/ 9
1¼”
1¼”
1¼”
1½”
1¼”
1¼”
263
2300
1000
SPU/80
1010
2070
Ø400
2”
½”/ 9
1¼”
1¼”
1¼”
2”
1¼”
1¼”
279
2305
1500
SPU/80
1120
2375
Ø400
2”
½”/ 9
1¼”
1¼”
1¼”
2”
1¼”
2”
376
2625
2000
SPU/80
1310
2280
Ø400
2”
½”/ 9
1¼”
1¼”
1¼”
2½”
1¼”
2”
462
2630
2500
SPU/80
1460
2160
Ø400
2”
½”/ 9
1½”
1½”
1½”
2½”
1¼”
2”
623
2610
3000
SPU/80
1460
2580
Ø500
2”
½”/ 9
1½”
1½”
1½”
2½”
1¼”
2”
700
2965
4000
SPU/80
1660
2575
Ø500
2”
½”/ 9
2”
2”
2”
3”
1¼”
2”
897
3065
5000
SPU/80
1660
3230
Ø500
2”
½”/ 9
2”
2”
2”
3”
1¼”
2”
1048
3635
Code Unit 11.18.20 11.18.21 11.18.22 11.18.23 11.18.24 11.18.25 11.18.26 11.18.27
The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
Volume 800L-5000L
Maximum Heating Power 466 kWh
Maximum Solar Collector Area 110 m2
Heat Exchanger Maximum Operating Temperature 110˚C
Heat Exchanger Maximum Operating Pressure 10 bar / 16 bar
Domestic Hot Water Maximum Operating Temperature 95˚C
Domestic Hot Water Maximum Operating Pressure 10 bar
Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.
Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
INSTALLATION DIAGRAM
Domestic Cold Water
Domestic Hot Water
Heating Water Inlet
Heating Water Return
11.19 KCD DOUBLE COPPER COIL WATER HEATER
24 25
Capacity
Insulation Type & Thickness
Diameter
Height
Lower Heat Exchanger (Serpantine) Flange Connection
Upper Heat Exchanger (Serpantine) Flange Connection
Electric Heater Connection
Thermometer / Steel Sensor Tube Connections
Domestic Cold Water Inlet Connection
Circulation Return Connection
Domestic Hot Water Outlet Connection
Lower Heat Exchanger (Coil) Inlet/Outlet Connections
Upper Heat Exchanger (Coil) Inlet/Outlet Connections
Electronic Anode Connection
Blind Connection
Gross Weight
Tilt Height
V
i
ØD
H
ØN1-1
ØN1-2
N2
N3
N4
N5
N6
N7
N8
N9
N10
G
R
lt
mm
mm
mm
mm
mm
inch
inch/mm
inch
inch
inch
inch
inch
inch
inch
kg
mm
800
SPU/80
910
2110
Ø400
Ø274
2”
½”/ 9
1¼”
1¼”
1¼”
2½”
1¼”
1¼”
1¼”
309
2300
1000
SPU/80
1010
2070
Ø400
Ø274
2”
½”/ 9
1¼”
1¼”
1¼”
2½”
1¼”
1¼”
1¼”
327
2305
1500
SPU/80
1120
2375
Ø400
Ø274
2”
½”/ 9
1¼”
1¼”
1¼”
2½”
1¼”
1¼”
2”
427
2625
2000
SPU/80
1310
2280
Ø400
Ø324
2”
½”/ 9
1¼”
1¼”
1¼”
2½”
1½”
1¼”
2”
526
2630
2500
SPU/80
1460
2160
Ø400
Ø400
2”
½”/ 9
1½”
1½”
1½”
2½”
1½”
1¼”
2”
697
2610
3000
SPU/80
1460
2580
Ø500
Ø400
2”
½”/ 9
1½”
1½”
1½”
2½”
2”
1¼”
2”
775
2965
4000
SPU/80
1660
2575
Ø500
Ø400
2”
½”/ 9
2”
2”
2”
3”
2”
1¼”
2”
981
3065
5000
SPU/80
1660
3230
Ø500
Ø400
2”
½”/ 9
2”
2”
2”
3”
2”
1¼”
2”
1136
3635
Code Unit 11.19.20 11.19.21 11.19.22 11.19.23 11.19.24 11.19.25 11.19.26 11.19.27
The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
N9
ØD
N3
N2
N6
N5
N4
N10
H
N7
N8
N8N12
N11
N7 STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Steel Sensor Tube
Cleaning & Control Flange
Magnesium Anode
Electronic Anode
Steel leg system mounted on a palette from 3 different locations
Circle steel leg system that provides circular floor contact
Electric Heater
Thermometer (0°C- 120°C)
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
STD/Ø9 mm 2 pieces
x
x
STD
x
OPS
STD
STD
x
OPS/2”
STD/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm
STD/Ø9 mm 2 pieces
x
x
STD
x
OPS
STD
STD-x
x-STD
OPS/2”
STD/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm OPS/100 mm
STD/Ø9 mm 2 pieces
STD/Ø274 mm STD/Ø400 mm
Upper Serpantine Lower Serpantine
STD/Ø274-Ø324 mm STD/Ø400 mm
STD/Ø400 mm STD/Ø400-Ø500 mm
STD/Ø400 mm STD/Ø500 mm
x
x
STD
x
OPS
STD
x
STD
OPS/2”
STD/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm
STD/Ø9 mm 2 pieces
x
x
STD
x
OPS
STD
x
STD
OPS/2”
STD/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm
800L-1000L 1500L-2000L 2500L-3000L 4000L-5000L
Volume 800L-5000L
Upper Heat Exchanger Maximum Heating Power 208 kWh
Lower Heat Exchanger Maximum Heating Power 466 kWh
Maximum Solar Collector Area 110 m2
Heat Exchanger Maximum Operating Temperature 110˚C
Heat Exchanger Maximum Operating Pressure 10 bar / 16 bar
Domestic Hot Water Maximum Operating Temperature 95˚C
Domestic Hot Water Maximum Operating Pressure 10 bar
Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.
Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
INSTALLATION DIAGRAM
Domestic Cold Water
Domestic Hot Water
Heating Water Inlet
Heating Water Return
11.23 KEB ELECTRIC WATER HEATER
26
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
N6
ØD
N2 N5
N4
N3
N8
N7
H
N1
Volume 100L – 5000L
Maximum Electrical Heating Power 105 kWe
Domestic Hot Water Maximum Operating Temperature 95°C
Domestic Hot Water Maximum Operating Pressure 10 Bar
Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.
STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Electric Heater
Residual Current Device
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Sheet Metal- Electrostatic Powder Painted Sheet
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Magnesium Anode
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)
Electronic Anode
Steel leg system mounted on a palette from 3 different locations
Circle steel leg system that provides circular floor contact
T&P Valve Connection
Steel Sensor Tube
Thermometer (0°C- 120°C)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
x
STD/ 1½” 2kW-30kW
STD/50 mm
STD
x
x
STD
STD/ ¾”
x
OPS
STD
x
OPS
STD/Ø63
x
x
x
x
STD/ 2” 2kW-105kW
x
x
x
STD
STD
STD/ ¾”
OPS
OPS
STD
x
OPS
STD/Ø100
x
STD/80 mm
OPS/80 mm
x
STD/ 2” 2kW-105kW
x
x
x
STD
STD
STD/ ¾”
OPS
OPS
STD-x
x-STD
OPS
STD/Ø100
x
STD/80 mm
OPS/80 mm OPS/100 mm
x x
STD/ 2” 2kW-105kW
STD/ 2” 2kW-105kW
x x
x x
x x
STD STD
STD STD
STD/ ¾” STD/ ¾”
OPS OPS
OPS OPS
x x
STD STD
OPS OPS
STD/Ø100 STD/Ø100
x x
STD/80 mm STD/80 mm
OPS/80 mm OPS/80 mm
100L-500L 800L-1000L 1500L-2000L 2500L-3000L 4000L-5000L
27
Capacity
Insulation Type & Thickness
Diameter
Height
Electric Heater Connection
Thermometer / Steel Sensor Tube Connections
Domestic Cold Water Inlet Connection
Circulation Return Connection
Domestic Hot Water Outlet Connection
Magnesium Anode Connection
P&T Valve Connection
Blind Connection
Gross Weight
Tilt Height
V
i
ØD
H
N1
N2
N3
N4
N5
N6
N7
N8
G
R
lt
mm
mm
mm
inch
inch/mm
inch
inch
inch
inch
inch
inch
kg
mm
100
PU/50
480
1110
½”/ 9
¾”
¾”
¾”
1¼”
¾”
1¼”
1210
160
PU/50
580
1135
½”/ 9
¾”
¾”
¾”
1¼”
¾”
1¼”
1275
200
PU/50
580
1340
½”/ 9
¾”
¾”
¾”
1¼”
¾”
1¼”
1460
300
PU/50
580
1860
½”/ 9
¾”
¾”
¾”
1¼”
¾”
1¼”
1950
500
PU/50
740
1845
½”/ 9
1”
¾”
1”
1¼”
¾”
1¼”
1990
800
SPU/80
910
2110
½”/ 9
1¼”
1”
1¼”
1¼”
¾”
1¼”
2300
1000
SPU/80
1010
2070
½”/ 9
1¼”
1”
1¼”
1¼”
¾”
1¼”
2305
1500
SPU/80
1120
2375
½”/ 9
1¼”
1”
1¼”
1¼”
¾”
2”
2625
3000
SPU/80
1460
2580
½”/ 9
1½”
1¼”
1½”
1¼”
¾”
2”
2965
2000
SPU/80
1310
2280
½”/ 9
1¼”
1”
1¼”
1¼”
¾”
2”
2630
4000
SPU/80
1660
2575
½”/ 9
1½”
1¼”
1½”
1¼”
¾”
2”
3065
2500
SPU/80
1460
2160
½”/ 9
1½”
1”
1½”
1¼”
¾”
2”
2610
5000
SPU/80
1660
3230
½”/ 9
1½”
1¼”
1½”
1¼”
¾”
2”
3635
Code Unit 11.23.11 11.23.13 11.23.14 11.23.16 11.23.18 11.23.20 11.23.21 11.23.22 11.23.2511.23.23 11.23.2611.23.24 11.23.27
The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
THE HEATER MAY BE CHOSEN OPTIONALLY
THE WEIGHT OF THE PRODUCTS MAY VARY ACCORDING TO CHOSEN HEATER/S. THE WEIGHT OF THE PRODUCTS WITHOUT HEATER/S ARE EQUAL TO ENAMELED ACCUMULATION TANK.
Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
INSTALLATION DIAGRAM
Domestic Cold Water
Domestic Hot Water
51.11 KAT ENAMELLED ACCUMULATION TANK
28
STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Steel Sensor Tube
Cleaning & Control Flange
Magnesium Anode
Electronic Anode
Steel leg system mounted on a palette from 3 different locations
Circle steel leg system that provides circular floor contact
Electric Heater
Thermometer (0°C- 120°C)
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
STD/Ø9 mm 2 pieces
STD/Ø125 mm OPS/Ø400 mm
x
x
STD
STD
OPS
OPS
STD
x
OPS/2”
STD/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm
800L-1000L
STD/Ø9 mm 2 pieces
STD/Ø100 mm
STD/50 mm
STD
x
STD
x
OPS
STD
x
OPS/1½”
STD/Ø63
x
x
x
100L-500L
STD/Ø9 mm 2 pieces
STD/Ø125 mm OPS/Ø400 mm
x
x
STD
STD
OPS
OPS
STD-x
x-STD
OPS/2”
STD/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm OPS/100 mm
1500L-2000L
STD/Ø9 mm 2 pieces
STD/Ø125 mm OPS/Ø400 mm
x
x
STD
STD
OPS
OPS
x
STD
OPS/2”
STD/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm
2500L-3000L
STD/Ø9 mm 2 pieces
STD/Ø125 mm OPS/Ø400 mm
x
x
STD
STD
OPS
OPS
x
STD
OPS/2”
STD/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm
4000L-5000L
29
Capacity
Insulation Type & Thickness
Diameter
Height
Primary/Secondary Energy Inlet/Outlet Connections
Cleaning & Control Flange Diameter
Thermometer / Steel Sensor Tube Connections
Circulation Return Connection
Electric Heater Connection
Magnesium Anode Connection
Blind Connection
Gross Weight
Tilt Height
lt
mm
mm
mm
inch
inch
inch/mm
inch
inch
inch
inch
kg
mm
100
PU/50
480
1110
1”
Ø100
½”/ 9
¾”
1½”
1¼”
1¼”
40
1210
160
PU/50
580
1135
1¼”
Ø100
½”/ 9
¾”
1½”
1¼”
1¼”
58
1275
200
PU/50
580
1340
1¼”
Ø100
½”/ 9
¾”
1½”
1¼”
1¼”
65
1460
300
PU/50
580
1860
1¼”
Ø100
½”/ 9
¾”
1½”
1¼”
1¼”
75
1950
500
PU/50
740
1845
1¼”
Ø100
½”/ 9
¾”
1½”
1¼”
1¼”
113
1990
800
SPU/80
910
2110
1½”
Ø125
½”/ 9
1¼”
2”
1¼”
1¼”
190
2300
1000
SPU/80
1010
2070
1½”
Ø125
½”/ 9
1¼”
2”
1¼”
1¼”
205
2305
1500
SPU/80
1120
2375
1½”
Ø125
½”/ 9
1¼”
2”
1¼”
2”
295
2625
2500
SPU/80
1460
2160
2”
Ø125
½”/ 9
1½”
2”
1¼”
2”
520
2610
4000
SPU/80
1660
2575
3”
Ø125
½”/ 9
2”
2”
1¼”
2”
760
3065
2000
SPU/80
1310
2280
1½”
Ø125
½”/ 9
1¼”
2”
1¼”
2”
370
2630
3000
SPU/80
1460
2580
2”
Ø125
½”/ 9
1½”
2”
1¼”
2”
575
2965
5000
SPU/80
1660
3230
3”
Ø125
½”/ 9
2”
2”
1¼”
2”
890
3635
V
i
ØD
H
N1
N2
N3
N4
N5
N6
N7
G
R
Code Unit 51.11.11 51.11.13 51.11.14 51.11.16 51.11.18 51.11.20 51.11.21 51.11.22 51.11.24 51.11.2651.11.23 51.11.25 51.11.27
The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
N6
ØD
N12 N14
N13
N7
H
N11
N33
N32
N31
N2
N5
N4
Volume 100L – 5000L
Domestic Hot Water Maximum Operating Temperature 95°C
Domestic Hot Water Maximum Operating Pressure 10 Bar
Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.
Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
INSTALLATION DIAGRAM
Domestic Cold Water
Domestic Hot Water
Heating Water Inlet
Heating Water Return
101.12 KCB-S SINGLE COIL COMBI BUFFER TANK
30
STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Steel Sensor Tube
Cleaning & Control Flange
Magnesium Anode
Electronic Anode
Steel leg system mounted on a palette from 3 different locations
Circle steel leg system that provides circular floor contact
Electric Heater
Thermometer (0°C- 120°C)
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
STD/Ø9 mm 4 pieces
STD/Ø125 mm STD/Ø125 mm STD/Ø125 mm
x
x
STD
STD
OPS
OPS
STD
x
OPS/2”
OPS/Ø100
STD/80 mm
OPS/80 mm
x
STD/Ø9 mm 4 pieces
STD/Ø100 mm
STD/50 mm
STD
x
STD
x
OPS
STD
x
OPS/1½”
OPS/Ø63
x
x
x
500L/ 100L-160L
800L-1000L/ 160L-200L
1500L/ 200L-350L
2000L/ 200L-350L
STD/Ø9 mm 4 pieces
x
x
STD
STD
OPS
OPS
STD
x
OPS/2”
OPS/Ø100
STD/80 mm
OPS/80 mm
x
STD/Ø9 mm 4 pieces
x
x
STD
STD
OPS
OPS
x
STD
OPS/2”
OPS/Ø100
STD/80 mm
OPS/80 mm
x
31
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
ØD
N14
N13 N17
N12 N16
N18
N15
N12
H
N11
N5
N6
N34
N33
N32
N31N2
N4
N3
N7N9
N8N10
N11
Capacity
Insulation Type & Thickness
Diameter
Height
Primary/Secondary Energy Inlet/Outlet Connections
Electric Heater Connection
Thermometer & Sensor Tube Connections
Drain Connection
Heat Exchanger (Serpantine) Inlet/Outlet Connections
Domestic Cold Water Inlet Connection
Domestic Hot Water Outlet Connection
Inner Tank Air Ventilating Connections
Outer Tank Air Ventilating Connections
Magnesium Anode Connection
Blind Connection
Gross Weight
Tilt Height
V
i
ØD
H
N1
N2
N3
N4
N5-N6
N7
N8
N9
N10
N11
N12
G
R
lt
mm
mm
mm
inch
inch
inch
inch
inch
inch
inch
inch
inch
inch
inch
kg
mm
500/100
PU/50
740
1845
1¼”
1½”
½”
1¼”
1¼”
¾”
¾”
½”
½”
1¼”
1¼”
176
1990
500/160
PU/50
740
1845
1¼”
1½”
½”
1¼”
1¼”
¾”
¾”
½”
½”
1¼”
1¼”
190
1990
800/160
SPU/80
910
2110
1¼”
2”
½”
1¼”
1¼”
¾”
¾”
½”
½”
1¼”
1¼”
290
2300
1000/160
SPU/80
1010
2070
1¼”
2”
½”
1¼”
1¼”
¾”
¾”
½”
½”
1¼”
1¼”
305
2305
1000/200
SPU/80
1010
2070
1¼”
2”
½”
1¼”
1¼”
¾”
¾”
½”
½”
1¼”
1¼”
317
2305
1500/200
SPU/80
1120
2375
1½”
2”
½”
1½”
1¼”
¾”
¾”
½”
½”
1¼”
2”
415
2625
1500/350
SPU/80
1120
375
1½”
2”
½”
1½”
1¼”
1”
1”
½”
½”
1¼”
2”
427
2625
2000/200
SPU/80
1310
2280
1½”
2”
½”
1½”
1¼”
1”
1”
½”
½”
1¼”
2”
510
2630
2000/350
SPU/80
1260
2280
1½”
2”
½”
1½”
1¼”
1”
1”
½”
½”
1¼”
2”
522
2605
Code Unit 101.12.18.1 101.12.18.2 101.12.20.2 101.12.21.2 101.12.21.3 101.12.22.3 101.12.22.4 101.12.23.3 101.12.23.4
The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
Volume 500L/100L-2000L/350L
Domestic Hot Water Maximum Operating Temperature 95°C
Domestic Hot Water Maximum Operating Pressure İç Tank: 6 bar / Dış Tank: 3 bar
Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.
Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
INSTALLATION DIAGRAM
Heating Water Inlet
Heating Water Return
Domestic Cold Water
Domestic Hot Water
51.12 KGA GALVANIZED ACCUMULATION TANK
32
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
N6
ØD
N12
N4
N11
N2
N14
N5
N13N31
N32
N33
N34
N7
H
STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Sensor Tube
Cleaning & Control Flange
Magnesium Anode
Electronic Anode
Steel leg system mounted on a palette from 3 different locations
Circle steel leg system that provides circular floor contact
Electric Heater
Thermometer (0°C- 120°C)
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
OPS/¾” 4 pieces
STD/DN100
x
x
STD
x
x
x
STD
x
OPS/1”-1¼”
x
STD/60 mm
OPS/60 mm
x
OPS/¾” 4 pieces
STD/DN125
x
x
STD
x
x
x
STD
x
OPS/1½”
x
STD/60 mm
OPS/60 mm
x
OPS/¾” 4 pieces
STD/DN150
x
x
STD
x
x
x
STD
x
OPS/2”
x
STD/60 mm
OPS/60 mm
x
OPS/¾” 4 pieces
STD/DN150
x
x
STD
x
x
x
STD
x
OPS/2”
x
STD/60 mm
OPS/60 mm
x
800L-1000L 1500L-2000L 2500L-3000L 4000L-5000L
33
Capacity
Insulation Type & Thickness
Diameter
Height
Primary/Secondary Energy Inlet/Outlet Connections
Cleaning & Control Flange Diameter
Thermometer & Sensor Connections
Electric Heater Connection
Circulation Return Connection
Air Ventilating Connection
Blind Connection
Gross Weight
Tilt Height
V
i
ØD
H
N1
N2
N3
N4
N5
N6
N7
G
R
lt
mm
mm
mm
inch
DN
inch
inch
inch
inch
inch
kg
mm
800
SPU/60
870
2100
1½”
DN100
¾”
1”
1”
1½”
1”
220
2275
1000
SPU/60
970
2090
2”
DN100
¾”
1¼”
1¼”
2”
1¼”
250
2305
1500
SPU/60
1080
2150
2½”
DN125
¾”
1½”
1½”
2½”
1½”
360
2475
2000
SPU/60
1270
2650
2½”
DN125
¾”
1½”
1½”
2½”
1½”
420
2920
2500
SPU/60
1420
2480
3”
DN150
¾”
2”
2”
3”
2”
490
2860
3000
SPU/60
1420
2880
3”
DN150
¾”
2”
2”
3”
2”
540
3215
4000
SPU/60
1620
2820
3”
DN150
¾”
2”
2”
3”
2”
820
3255
5000
SPU/60
1620
3420
3”
DN150
¾”
2”
2”
3”
2”
930
3790
Code Unit 51.12.20 51.12.21 51.12.22 51.12.23 51.12.24 51.12.25 51.12.26 51.12.27
The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
Volume 800L – 5000L
Domestic Hot Water Maximum Operating Temperature 95°C
Domestic Hot Water Maximum Operating Pressure 10 Bar / 16 bar
Inner Surface Coating Tank is made of S355J2 quality steel and galvanized in accordance with TS EN ISO 1461 standard.
Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
INSTALLATION DIAGRAM
Heating Water Inlet
Heating Water Return
Domestic Cold Water
Domestic Hot Water
101.13 KBT-B BUFFER TANK
34 35
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
Volume 100L – 5000L
Domestic Hot Water Maximum Operating Temperature 95°C
Domestic Hot Water Maximum Operating Pressure 6 Bar
N5
ØD
N14
N13 N17
N12 N16
N18
N15
N6
H
N11
N33
N32
N31
N2
N4
STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Cleaning & Control Flange
Electric Heater
Magnesium Anode
Electronic Anode
Steel leg system mounted on a palette from 3 different locations
Circle steel leg system that provides circular floor contact
Air Ventilating Connection
Steel Sensor Tube
Thermometer (0°C- 120°C)
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
x x x x x x
OPS/Ø9 mm 3 pieces
OPS/Ø9 mm 3 pieces
OPS/Ø9 mm 3 pieces
OPS/Ø9 mm 3 pieces
OPS/Ø9 mm 3 pieces
OPS/Ø9 mm 3 pieces
STD/50 mm STD/50 mm
STD STD
x x
x x
STD/1¼” STD/1¼”
x x
x x
STD STD
x x
x OPS/1½”
OPS/Ø63 OPS/Ø63
x x
x x
x x
x
x
STD
x
STD/1¼”
OPS
x
STD
x
OPS/2”
OPS/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm
x
x
STD
x
STD/1¼”
OPS
x
STD-x
x-STD
OPS/2”
OPS/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm OPS/100 mm
x x
x x
STD STD
x x
STD/1¼” STD/1¼”
OPS OPS
x x
x x
STD STD
OPS/2” OPS/2”
OPS/Ø100 OPS/Ø100
STD/80 mm STD/80 mm
OPS/80 mm OPS/80 mm
OPS/80 mm OPS/80 mm
100L-300L 500L 800L-1000L 1500L-2000L 2500L-3000L 4000L-5000L
Capacity
Insulation Type & Thickness
Diameter
Height
Primary/Secondary Energy Inlet/Outlet Connections*
Electric Heater Connection
Thermometer & Sensor Tube Connections
Drain Connection
Air Ventilating Connection
Blind Connection
Gross Weight
Tilt Height
lt
mm
mm
mm
inch
inch
inch
inch
inch
inch
kg
mm
100
PU/50
480
1110
1”
-
½”
1”
1¼”
1¼”
36
1210
160
PU/50
580
1135
1¼”
-
½”
1¼”
1¼”
1¼”
54
1275
200
PU/50
580
1340
1¼”
-
½”
1¼”
1¼”
1¼”
60
1460
300
PU/50
700
1220
1¼”
-
½”
1¼”
1¼”
1¼”
70
1410
500
PU/50
740
1845
1¼”
1½”
½”
1¼”
1¼”
1¼”
106
1990
800
SPU/80
910
2110
1½”
2”
½”
1½”
1¼”
1¼”
183
2300
1000
SPU/80
1010
2070
1½”
2”
½”
1½”
1¼”
1¼”
197
2305
1500
SPU/80
1120
2375
1½”
2”
½”
1½”
1¼”
2”
286
2625
2500
SPU/80
1460
2160
2”
2”
½”
2”
1¼”
2”
510
2610
4000
SPU/80
1660
2575
3”
2”
½”
3”
1¼”
2”
745
3065
2000
SPU/80
1310
2280
1½”
2”
½”
1½”
1¼”
2”
360
2630
3000
SPU/80
1460
2580
2”
2”
½”
2”
1¼”
2”
563
2965
5000
SPU/80
1660
3230
3”
2”
½”
3”
1¼”
2”
870
3635
V
i
ØD
H
N1
N2
N3
N4
N5
N6
G
R
Code Unit 101.13.11 101.13.13 101.13.14 101.13.16 101.13.18 101.13.20 101.13.21 101.13.22 101.13.24 101.13.26101.13.23 101.13.25 101.13.27
The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
* : The number of energy inlet/outlet connections is 4 for 100L-300L products, 2 for the primary circuit, 2 for the secondary circuit; and 8 for 500L-5000L products, 4 for the primary circuit, and 4 for the secondary circuit.
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
INSTALLATION DIAGRAM
Heating Water Inlet
Heating Water Return
101.14 KBT-S SINGLE COIL BUFFER TANK
36 37
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
N7
ØD
N14
N13 N17
N12 N16
N18
N15
N8
H
N11
N33
N32N6
N5
N31
N2
N4STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Cleaning & Control Flange
Electric Heater
Magnesium Anode
Electronic Anode
Steel leg system mounted on a palette from 3 different locations
Circle steel leg system that provides circular floor contact
Air Ventilating Connection
Steel Sensor Tube
Thermometer (0°C- 120°C)
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
x
OPS/Ø9 mm 3 pieces
STD/50 mm
STD
x
x
STD/1¼”
x
x
STD
x
x
OPS/Ø63
x
x
x
160L-300L
x
OPS/Ø9 mm 3 pieces
STD/50 mm
STD
x
x
STD/1¼”
x
x
STD
x
OPS/1½”
OPS/Ø63
x
x
x
500L
x
OPS/Ø9 mm 3 pieces
x
x
STD
x
STD/1¼”
OPS
x
STD
x
OPS/2”
OPS/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm
800L-1000L
x
OPS/Ø9 mm 3 pieces
x
x
STD
x
STD/1¼”
OPS
x
STD-x
x-STD
OPS/2”
OPS/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm OPS/100 mm
1500L-2000L
x
OPS/Ø9 mm 3 pieces
x
x
STD
x
STD/1¼”
OPS
x
x
STD
OPS/2”
OPS/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm
2500L-3000L
Capacity
Insulation Type & Thickness
Diameter
Height
Primary/Secondary Energy Inlet/Outlet Connections*
Electric Heater Connection
Thermometer & Sensor Tube Connections
Heat Exchanger (Coil) Inlet/Outlet Connections
Drain Connection
Air Ventilating Connection
Blind Connection
Gross Weight
Tilt Height
lt
mm
mm
mm
inch
inch
inch
inch
inch
inch
inch
kg
mm
160
PU/50
580
1135
1¼”
-
½”
1¼”
1¼”
1¼”
1¼”
70
1275
200
PU/50
580
1340
1¼”
-
½”
1¼”
1¼”
1¼”
1¼”
71
1460
300
PU/50
700
1220
1¼”
-
½”
1¼”
1¼”
1¼”
1¼”
93
1410
500
PU/50
740
1845
1¼”
1½”
½”
1¼”
1¼”
1¼”
1¼”
143
1990
800
SPU/80
910
2110
1½”
2”
½”
1½”
1¼”
1¼”
1¼”
238
2300
1000
SPU/80
1010
2070
1½”
2”
½”
1½”
1¼”
1¼”
1¼”
252
2305
1500
SPU/80
1120
2375
1½”
2”
½”
1½”
1¼”
1¼”
2”
351
2625
2000
SPU/80
1310
2280
1½”
2”
½”
1½”
1¼”
1¼”
2”
445
2630
3000
SPU/80
1460
2580
2”
2”
½”
2”
1½”
1¼”
2”
722
2965
2500
SPU/80
1460
2160
2”
2”
½”
2”
1½”
1¼”
2”
640
2610
V
i
ØD
H
N1
N2
N3
N4
N5-N6
N7
N8
G
R
Code Unit 101.14.13 101.14.14 101.14.16 101.14.18 101.14.20 101.14.21 101.14.22 101.14.23 101.14.25101.14.24
The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
* : The number of energy inlet/outlet connections is 4 for 100L-300L products, 2 for the primary circuit, 2 for the secondary circuit; and 8 for 500L-3000L products, 4 for the primary circuit, and 4 for the secondary circuit.
Volume 160L – 3000L
Domestic Hot Water Maximum Operating Temperature 95°C
Domestic Hot Water Maximum Operating Pressure 6 Bar
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
INSTALLATION DIAGRAM
Heating Water Inlet
Heating Water Return
101.15 KBT-D DOUBLE COIL BUFFER TANK
38 39
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
N9
ØD
N14
N13 N17
N12 N16
N18
N15
N10
H
N11
N33
N32N6
N7
N8
N5
N31
N2
N4STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Cleaning & Control Flange
Electric Heater
Magnesium Anode
Electronic Anode
Steel leg system mounted on a palette from 3 different locations
Circle steel leg system that provides circular floor contact
Air Ventilating Connection
Steel Sensor Tube
Thermometer (0°C- 120°C)
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
x
OPS/Ø9 mm 3 pieces
STD/50 mm
STD
x
x
STD/1¼”
x
x
STD
x
x
OPS/Ø63
x
x
x
160L-300L
x
OPS/Ø9 mm 3 pieces
STD/50 mm
STD
x
x
STD/1¼”
x
x
STD
x
OPS/1½”
OPS/Ø63
x
x
x
500L
x
OPS/Ø9 mm 3 pieces
x
x
STD
x
STD/1¼”
OPS
x
STD
x
OPS/2”
OPS/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm
800L-1000L
x
OPS/Ø9 mm 3 pieces
x
x
STD
x
STD/1¼”
OPS
x
STD-x
x-STD
OPS/2”
OPS/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm OPS/100 mm
1500L-2000L
x
OPS/Ø9 mm 3 pieces
x
x
STD
x
STD/1¼”
OPS
x
x
STD
OPS/2”
OPS/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm
2500L-3000L
Capacity
Insulation Type & Thickness
Diameter
Height
Primary/Secondary Energy Inlet/Outlet Connections
Electric Heater Connection
Thermometer & Sensor Tube Connections
Lower Heat Exchanger (Coil) Inlet/Outlet Connections
Upper Heat Exchanger (Coil) Inlet/Outlet Connections
Drain Connection
Air Ventilating Connection
Blind Connection
Gross Weight
Tilt Height
lt
mm
mm
mm
inch
inch
inch
inch
inch
inch
inch
inch
kg
mm
160
PU/50
580
1135
1¼”
-
½”
1¼”
1¼”
1¼”
1¼”
1¼”
78
1275
200
PU/50
580
1340
1¼”
-
½”
1¼”
1¼”
1¼”
1¼”
1¼”
86
1460
300
PU/50
700
1220
1¼”
-
½”
1¼”
1¼”
1¼”
1¼”
1¼”
102
1410
500
PU/50
740
1845
1¼”
1½”
½”
1¼”
1¼”
1¼”
1¼”
1¼”
170
1990
800
SPU/80
910
2110
1½”
2”
½”
1½”
1¼”
1¼”
1¼”
1¼”
268
2300
1000
SPU/80
1010
2070
1½”
2”
½”
1½”
1¼”
1¼”
1¼”
1¼”
282
2305
1500
SPU/80
1120
2375
1½”
2”
½”
1½”
1¼”
1¼”
1¼”
2”
381
2625
2000
SPU/80
1310
2280
1½”
2”
½”
1½”
1¼”
1¼”
1¼”
2”
490
2630
3000
SPU/80
1460
2580
2”
2”
½”
2”
1½”
1½”
1¼”
2”
793
2965
2500
SPU/80
1460
2160
2”
2”
½”
2”
1½”
1½”
1¼”
2”
710
2610
V
i
ØD
H
N1
N2
N3
N4
N5-N6
N7-N8
N9
N10
G
R
Code Unit 101.15.13 101.15.14 101.15.16 101.15.18 101.15.20 101.15.21 101.15.22 101.15.23 101.15.25101.15.24
The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
* : The number of energy inlet/outlet connections is 4 for 100L-300L products, 2 for the primary circuit, 2 for the secondary circuit; and 8 for 500L-3000L products, 4 for the primary circuit, and 4 for the secondary circuit.
Volume 160L – 3000L
Domestic Hot Water Maximum Operating Temperature 95°C
Domestic Hot Water Maximum Operating Pressure 6 Bar
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
INSTALLATION DIAGRAMHeating Water Inlet
Heating Water Inlet
Heating Water Return
Heating Water Return
101.16 KBT-CB HYDRAULIC BALANCING BUFFER TANK
40
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
N2
ØD
N12
N11
N14
N13
N3
H
STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.* Polyurethane insulation can be applied with threaded connection on request for bulk order.
Cleaning & Control Flange
Electric Heater
Magnesium Anode
Electronic Anode
Steel leg system mounted on a palette from 3 different locations
Circle steel leg system that provides circular floor contact
Air Ventilating Connection
Thermometer (0°C- 120°C)
Steel Sensor Tube
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
x
x
x
x
STD
x
OPS
x
STD
x
STD/1¼”
x
x
STD/80 mm
x
OPS/80 mm
800L-1000L
x
x
OPS/50 mm
x
STD
x
x
x
STD
x
STD/1¼”
x
x
STD/80 mm
x
x
100L-500L
x
x
x
x
STD
x
OPS
x
STD-x
x-STD
STD/1¼”
x
x
STD/80 mm
x
OPS/80 mm OPS/100 mm*
1500L-2000L
x
x
x
x
STD
x
OPS
x
x
STD
STD/1¼”
x
x
STD/80 mm
x
OPS/80 mm
2500L-3000L
x
x
x
x
STD
x
OPS
x
x
STD
STD/1¼”
x
x
STD/80 mm
x
OPS/80 mm
4000L-5000L
41
Capacity
Insulation Type & Thickness
Diameter
Height
Primary/Secondary Energy Inlet/Outlet Connections
Air Ventilating Connection
Blind Connection
Gross Weight
Tilt Height
V
i
ØD
H
N1
N2
N3
G
R
lt
mm
mm
mm
inch/DN
inch
inch
kg
mm
100
SPU/80
540
1115
Threaded 1½”
1¼”
1¼”
46
1240
300
SPU/80
760
1225
Threaded 2”
1¼”
1¼”
80
1440
500
SPU/80
800
1850
Threaded 2½”
1¼”
1¼”
118
2015
800
SPU/80
910
2110
Flanged DN80
1¼”
1¼”
199
2300
1000
SPU/80
1010
2070
Flanged DN100
1¼”
1¼”
215
2305
1500
SPU/80
1120
2375
Flanged DN125
1¼”
2”
311
2625
3000
SPU/80
1460
2580
Flanged DN150
1¼”
2”
593
2965
2000
SPU/80
1310
2280
Flanged DN145
1¼”
2”
385
2630
4000
SPU/80
1660
2575
Flanged DN200
1¼”
2”
806
3065
2500
SPU/80
1460
2160
Flanged DN150
1¼”
2”
540
2610
5000
SPU/80
1660
3230
Flanged DN200
1¼”
2”
931
3635
Code Unit 101.16.11 101.16.16 101.16.18 101.16.20 101.16.21 101.16.22 101.16.25101.16.23 101.16.26101.16.24 101.16.27
The table shown above is prepared based on spare parts and equipments which belong to the standard products; products 100L-300L have internal thread connection, products 800L-5000L have flaged connection.
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
Volume 100L – 5000L
Domestic Hot Water Maximum Operating Temperature 95°C
Domestic Hot Water Maximum Operating Pressure 6 Bar
Flange Connection Pressure Class PN16
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Izoqua- Dışarıda kullanıma uygun su geçirmez PVC kullanım ünitesi (Izomax izolasyonu kullanıldığı takdirde, opsiyonel olarak sunulur.)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
INSTALLATION DIAGRAM
Coolingor
HeatingSystem
101.17 KBT-C BUFFER TANK WITH BAFFLE PLATE
42
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
N2
ØD
N11 N12
N3
H
STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Cleaning & Control Flange
Electric Heater
Magnesium Anode
Electronic Anode
Steel leg system mounted on a palette from 3 different locations
Circle steel leg system that provides circular floor contact
Air Ventilating Connection
Thermometer (0°C- 120°C)
Steel Sensor Tube
INSU
LATI
ON
CO
ATIN
GEQ
UIP
MEN
TCA
THO
DIC
PR
OTE
C-TI
ON
CARR
IER
ELEM
ENT
x
x
x
x
STD
x
OPS
x
STD
x
STD/1¼”
x
x
STD/80 mm
x
OPS/80 mm
800L-1000L
x
x
x
x
STD
x
x
x
STD
x
STD/1¼”
x
x
STD/80 mm
x
x
100L-500L
x
x
x
x
STD
x
OPS
x
STD-x
x-STD
STD/1¼”
x
x
STD/80 mm
x
OPS/80 mm OPS/100 mm*
1500L-2000L
x
x
x
x
STD
x
OPS
x
x
STD
STD/1¼”
x
x
STD/80 mm
x
OPS/80 mm
2500L-3000L
x
x
x
x
STD
x
OPS
x
x
STD
STD/1¼”
x
x
STD/80 mm
x
OPS/80 mm
4000L-5000L
43
Capacity
Insulation Type & Thickness
Diameter
Height
Number of Baffle
Primary/Secondary Energy Inlet/Outlet Connections
Air Ventilating Connection
Blind Connection
Gross Weight
Tilt Height
V
i
ØD
H
-
N1
N2
N3
G
R
lt
mm
mm
mm
pieces
DN
inch
inch
kg
mm
100
SPU/80
540
1115
Flanged DN50
1¼”
1¼”
40
1240
300
SPU/80
760
1225
Flanged DN50
1¼”
1¼”
78
1440
1
500
SPU/80
800
1850
Flanged DN65
1¼”
1¼”
117
2015
800
SPU/80
910
2110
Flanged DN80
1¼”
1¼”
198
2300
1000
SPU/80
1010
2070
Flanged DN100
1¼”
1¼”
232
2305
1500
SPU/80
1120
2375
Flanged DN125
1¼”
2”
325
2625
3000
SPU/80
1460
2580
Flanged DN150
1¼”
2”
701
2965
2000
SPU/80
1310
2280
Flanged DN125
1¼”
2”
405
2630
4000
SPU/80
1660
2575
Flanged DN200
1¼”
2”
894
3065
2500
SPU/80
1460
2160
Flanged DN150
1¼”
2”
577
2610
5000
SPU/80
1660
3230
Flanged DN200
1¼”
2”
931
3635
Code Unit 101.17.11 101.17.16 101.17.18 101.17.20 101.17.21 101.17.22 101.17.25101.17.23 101.17.26101.17.24 101.17.27
The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have flanged connection.
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
2 3
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
Volume 100L – 5000L
Domestic Hot Water Maximum Operating Temperature 95°C
Domestic Hot Water Maximum Operating Pressure 6 Bar
Flange Connection Pressure Class PN16
INSTALLATION DIAGRAM
Coolingor
HeatingSystem
911 KPG AUTOMATIC PUMP CONTROLLED EXPANSION SYSTEM
44
The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.
45
Capacity
Maximum Allowable Working Pressure
Width
Depth
Height
Domestic Cold Water Inlet Connection
Expansion Line Inlet Connection
Pressurization Line Outlet Connection
Storage Tank Connection
Maximum Flolw Rate
Power
Gross Weight
Tilt Height
V
P
D1
D2
H
N1
N2
N3
N4
Q
Ppower
G
R
Code
lt
bar
mm
mm
mm
inch
icnh
inch
inch
m3/h
kW
kg
mm
Unit
min 500L
6
650
650
960
1”
1”
1”
1¼”
6
1,8
135
1100
101.17.11
min 500L
10
650
650
960
1”
1”
1”
1¼”
1
2,7
142
1100
101.17.16
min 500L
16
650
650
960
1”
1”
1”
1¼”
3,2
4,9
160
1100
101.17.18
The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have flanged connection.
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
Capasity Min. 500LTank 51.11 Enameled Accumulation TankPump Grundfos CM SerieControl System 7” Touch PanelMaximum Operating Temperature 95˚CMaximum Operating Pressure 6 bar / 10 bar / 16 barControl Circuit Voltage 230 V ACAutomatic Filling System Avaliable
INSTALLATION DIAGRAM
Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.
Automatic Pump Controlled Expansion System is a technological devices developed to absorb the volume changes that may occur at the heating and cooling systems and stabilize the installment pressure.
Considering the expansion and contraction of water due to the temperature variation, the amount of water changes in the system. The device keeps the pressure in the installment in balance with 0,1 bar precision by transmitting the water among the tank and installment through the proportioning valves and pumps.
STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.
Cleaning & Control Flange
Pump
PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards
Sheet Metal- Electrostatic Powder Painted Sheet
Blueshell- Recyclable polyethylene cover that provides heat-saving
Vinleks- Artificial Leather
Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)
Steel leg system mounted on a palette from 3 different locations
Circle steel leg system that provides circular floor contact
Rubber leg system mounted on a cell from 4 locations
Automatic Filling System
Steel Sensor Tube
Thermometer (0°C- 120°C)
Soft PU- 15 kg/m3 soft polyurethane
Soft PU- 26 kg/m3 flame retardant soft polyurethane
Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards
INSU
LATI
ON
TAN
KTA
NK
TAN
KTA
NK
UN
ITU
NIT
UN
IT
CO
ATIN
GEQ
UIP
MEN
TCA
RRIE
R EL
EMEN
T
OPS/Ø9 mm 2 pieces
OPS/Ø9 mm 2 pieces
OPS/Ø9 mm 2 pieces
OPS/Ø9 mm 2 pieces
OPS/Ø9 mm 2 pieces
STD/4”
STD/50 mm
x
STD
x
STD
STD
STD
x
STD
STD
STD/Ø63
x
x
x
STD/5” OPS/16”
x
STD
x
OPS
STD
STD
STD
x
STD
STD
STD/Ø100
STD/80 mm
OPS/80 mm
OPS/80 mm
STD/5” OPS/16”
x
STD
x
OPS
STD
STD
STD-x
x-STD
STD
STD
STD/Ø100
STD/80 mm
STD/80 mm
OPS/80 mm OPS/100 mm*
500L 800L-1000L 1500L-2000L
STD/5” OPS/16”
x
STD
x
OPS
STD
STD
x
STD
STD
STD
STD/Ø100
STD/80 mm
STD/80 mm
OPS/80 mm
2500L-3000L
STD/5” OPS/16”
x
STD
x
OPS
STD
STD
x
STD
STD
STD
STD/Ø100
STD/80 mm
STD/80 mm
OPS/80 mm
4000L-5000L
|IMPORTANT NOTES
• We highly recommend to follow instructions specified at the user and installation guide attached to your product in order to secure of using it in safe and efficient.
• Safety Valve, expansion tank and, if required, pressure reducer valve should be used with our products (water heaters and storage tanks).
• KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.
• You may contact Kodsan for more details about your product.
Two-Way Motorized Valve
Ball ValveDrain Valve
Shut Off Valve
Pressure Relief Valve
Air Relief Cock
Radiator or Underfloor Heating System
Pressure Gauge
Air Separator
SolarPanel
HeatPump
Heat Exchanger
Combi
Usage Area
Dirt Separator
Membrane Expansion Tank
Underfloor Heating
Radiator
Thermometer
Safety Thermostat
Twin-Head Pump
Pump
Three-Way Motorized Valve
Three-Way Thermostatic Valve
Pressure Release Valve
Thermostatic Check Valve
Bypass Valve
Three-Way Modulating Motorized Valve
Check Valve
Strainer
|SYMBOLS
46 47
www.kodsan.com.tr