![Page 1: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/1.jpg)
X-Band Technology OverviewAnd Applications
Chris AdolphsenSLAC
![Page 2: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/2.jpg)
The history of X-Band (11.4 GHz) rf technology development naturallydivides into two parts:
1) From the late 1980’s to 2004, development aimed at demonstratingviability for the proposed Next Linear Collider (NLC)
SLAC spearheads this effort with a major contribution from KEK, and later,FNAL on structure development
2) After the 2004 International Technology Review Panel (ITRP) selected L-Bandsuperconducting rf technology for the International Linear Collider (ILC):
Continue X-band structure and rf source work at a low levelIn 2007, CERN Compact Linear Collider (CLIC) chooses 12 GHz (from30 GHz) and the SLAC/CERN/KEK X-band structure collaboration rampsup along with the more forward looking US High Gradient ProgramLCLS success with low bunch charge operation makes a compact X-bandlinac driven XFELs a possibilityILC cost, LHC delay and the CLIC drive beam risk has prompted interestin using X-band klystrons for the initial stage of CLIC
Overview
![Page 3: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/3.jpg)
Chose X-Band technology as an evolutionary next step for the Next Linear
Collider (NLC) from the SLAC Linac S-Band (2.86 GHz) technology.
In general want higher rf frequency because:
- Less rf energy per pulse is required, so fewer/smaller rf components.
- Higher gradients achievable, so shorter linacs (with reasonable efficiencies)
Offsetting these advantages are the requirements of:
- High power (100’s MW) HV pulses with fast rise times (100’s ns).
- High surface gradients in the klystrons, waveguide transport system and
accelerator structures.
- Tight alignment tolerances due to stronger wakefields (much less an issue
for light sources where the bunch charge is low, and bunch length short).
X-Band (11.4 GHz) RF Technology
![Page 4: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/4.jpg)
SLAC Linac RF Unit(One of 240, 50 GeV Beam)
![Page 5: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/5.jpg)
NLC Linac RF Unit(One of ~ 2000 at 500 GeV cms, One of ~ 4000 at 1 TeV cm)
![Page 6: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/6.jpg)
Next Linear Collider Test Accelerator (NLCTA)
In 1993, construction beganusing first generation X-Bandcomponents.
In 1997, demonstrated 17%beam loading compensationin four, 1.8 m structures at~ 40 MV/m.
In 2000-10, used for highgradient studies and otherprograms (E163, Echo)
Future: Test X-band guns, rfsystems and light sourcebunching/emittance schemes
![Page 7: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/7.jpg)
2003Eight-Pack Project:Second GenerationRF Unit Test
![Page 8: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/8.jpg)
RF Component Performance
![Page 9: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/9.jpg)
Solid State Induction Modulator
![Page 10: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/10.jpg)
Waveforms When Driving Four 50 MWKlystrons at 400 kV, 300 A Each
Eight-Pack Modulator76 CoresThree-Turn Secondary> 1500 Hours of Operation
![Page 11: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/11.jpg)
Next Generation Induction Modulator:The ‘Two-Pack’
Features- 6.5 kV IGBTs with in-line
multi-turn 1:10 transformer.- Industrialized cast casings.- Improved oil cooling.- Improved HV feed through.
Bechtel-LLNL-SLAC 20 kV Test Stack
A Hybrid 2-Pack Modulator (15 core stackdriving a conventional 1:10 transformer) was
built and is still being used – also built aversion to drive a single ‘5045’ S-Band Tube
2-Pack Layout(never built)
![Page 12: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/12.jpg)
Recent Industrialization of SolidState Induction Modulators
Specification :
High Voltage : 450 kV
Current : 335 A
Flat pulse length: 1.5 µs
Pulse length at 50%: 2.3 µs
Repetition rate: 50 Hz
HV ripple: ± 0.25 %
Pulse to pulse stability: ± 0.1 %
(1.8 x 3 x 2 m3)
SCANDINOVA
SLAC XL5Klystron Solid State Switch
modules
Magnet and Ionpump powersupplies
Water coolingcircuit
Oil tank withpulse transfomer Tuning circuit
Oil pump andfilter
![Page 13: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/13.jpg)
NLC legacy: employ solid state switching technology ina 120 kV Marx (capacitive adder) Modulator for ILC
SLAC Marx Modulator driving a 10 MW L-Band(1.3 GHz) Multi-Beam Klystron at ESB
![Page 14: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/14.jpg)
RF Component Performance
![Page 15: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/15.jpg)
X-Band Klystrons
‘XL4’ – Have built at least 15, now producing 12 GHz ‘XL5’ versions
![Page 16: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/16.jpg)
Four 50 MW XL4 Klystrons Installed in the Eight-PackModulator in 2004
![Page 17: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/17.jpg)
PPM Klystron Performance(75 MW, 1.6 s, 120/150 Hz, 55% Efficiency Required)
SLACTwo tubes tested at
75 MW with1.6 s pulses at
120 Hz.Efficiency = 53-54%.
KEK/ToshibaFour tubes tested at75 MW with1.6 s pulses at50 Hz (modulator limited).Efficiency = 53-56%.
![Page 18: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/18.jpg)
• At 75 MW, iris surface field ~ 70 MV/m,lower than in structures (~ 200 MV/m),but higher than sustainable (~ 50 MV/m)in waveguide with comparable groupvelocity (~ 20%).
• May require multi-beam klystronapproach for stable > 50 MW, 1.6 soperation.
KEK PPM2Output
Structure
Time (100 ns / div)
Reflected
TransmittedPow
er –
Nor
mal
Pul
sePo
wer
–Te
ar E
vent
Klystron Tear Events
14 mm
![Page 19: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/19.jpg)
SEM Photos of a 75 MW PPM Klystron Output Section
![Page 20: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/20.jpg)
KEK PPM Legacy
Toshiba currently advertizes this de-rated
75 MW PPM tube that at 470 kV, is spec’ed
to deliver 50 MW (max) in 400 ns pulses at
50 Hz with a 43% (min) efficiency
![Page 21: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/21.jpg)
Currently using rf-driven klystron output sectionsto study stability and evaluate future designs
![Page 22: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/22.jpg)
RF Component Performance
![Page 23: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/23.jpg)
First Generation RF Pulse Compression(SLED II) at NLCTA
![Page 24: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/24.jpg)
TE01
TE02
TE02
TE01
For NLC, Use Dual ModedDelay Line to Reduce DelayLine Length in Half
![Page 25: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/25.jpg)
Also Use Over-Height Planar Waveguideto Lower Surface Fields
Design for < 50 MV/m for 400 ns pulses
Example: Power Splitter
![Page 26: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/26.jpg)
Dual-Moded SLED-II Performance(475 MW, 400 ns Pulses Required for NLC)
Combined Klystron Power
Output Power
(Gain = 3.1, Goal = 3.25)
Since 2004, have done low power tests using silicon andplasma switches to improve efficiency
![Page 27: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/27.jpg)
DownstreamUpstream
Surface rf power cluster building 2 groups of ~35 10 MW klystrons & modulatorsclustered in a surface building
~350 MW combined into each of 2 overmoded,low-loss waveguides
Feeds ~2.5 km of linac total (up & downstream)
• Service tunnel eliminated
• Underground heat load greatly reduced
NLC legacy: use waveguide mode conversion/transporttechniques to power ILC from klystron clusters
Accelerator Tunnel TE01 waveguide
![Page 28: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/28.jpg)
RF Component Performance
![Page 29: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/29.jpg)
NLC Accelerator Structure Requirements
Convert rf energy to beam energy efficiently.
Short-range transverse wakefields small to limit linac emittance
growth: iris radius limited to 17% of rf wavelength (i.e. a/ = 17%).
Long-range wakefields suppressed so bunch train effectively acts as
a single bunch.
Dipole mode power coupled out for use as guide for centering the
beam in the structure.
Operate reliably at the design gradient and pulse length.
NLC/GLC Structures were developed by a FNAL/KEK/SLAC collaboration –
CERN/KEK/SLAC now developing 11%-13% a/ structures that run at ~ 100 MV/m
![Page 30: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/30.jpg)
NLC High Gradient Structure Development
50 cm ‘T53’ StructureSince 1999:
- Tested about 40 structures with over 30,000hours of high power operation at NLCTA.
- Improved structure preparation procedures -includes various heat treatments andavoidance of high rf surface currents.
- Found lower input power structures to bemore robust against rf breakdown induceddamage (CLIC has ‘pushed’ this further andalso shortened the rf pulse length)
- Developed NLC-Ready ‘H60’ design withrequired wakefield suppression features.
![Page 31: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/31.jpg)
Ready for Coupler Braze After Braze
Structure Fabrication at SLAC
![Page 32: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/32.jpg)
H60 Structure Cells and Coupler Assembly
Cells with Slotsfor Dipole ModeDamping
Port for ExtractingDipole Mode Power
Output Coupler
CLIC Cells HaveLarge WaveguideOpenings forFaster Damping
![Page 33: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/33.jpg)
Wakefield Damping andDetuning
Time ofNext Bunch
Time After Bunch (ns)
Wak
efie
ld A
mpl
itude
(V/p
C/m
/mm
)
Measurements
Ohmic Loss Only
Damping and Detuning
Detuning Only
Dipole Mode Density
Frequency (GHz)
![Page 34: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/34.jpg)
RF Unit Test in2003-2004
FromEight-Pack
3 dB3 dB
3 dB
3 dB3 dB
Beam
FromStation 2
FromStation 1
Powered Eight H60accelerator structures in
NLCTA for 1500 hours at 65MV/m with 400 ns long
pulses at 60 Hz andaccelerated beam
![Page 35: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/35.jpg)
0 200 40 0 6 00 800 100010
- 2
10- 1
0 5 00 100010
- 2
10- 1
0 20 0 400 6 00 80010
- 2
10- 1
0 20 0 400 6 00 80010
- 2
10- 1
Hours of Operation
Breakdown Rate History (Goal < 0.1/hr)Four H60 Structures at 65 MV/m
= 400 hr = 600 hr
= 400 hr = 400 hr
Brea
kdow
n R
ate
at 6
0 H
z (#
/hr)
with
400
ns
Puls
es
Hours of Operation
![Page 36: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/36.jpg)
CLIC 3-TeV Layout
CERN/KEK/SLAC Collaboration hasbeen evaluating ~ 20 cm X-Banddisk structures since 2008
![Page 37: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/37.jpg)
CLIC T18-Disk Structure(First attempt at an optimal CLIC structure)
Field Profile Along the Structure
Cells 18+input+output
Filling Time: ns 36
Active Length: cm 17.5
a/ (%) 15.5 ~ 10.1
vg/c (%) 2.6 - 1.0
Phase Advance Per Cell 2 /3
Power Needed <Ea> = 100 MV/m 55.5 MW
Es/Ea 2
Require breakdown rate < 4e-7 /pulse/mwith 230 ns pulses
Undamped (no waveguides) T18 achievedthis at ~ 102 MV/m
Damped T18 (with waveguides) achievedthis at ~ 85 MV/m
As with NLC, the gradient including beamloading will be 10-20 MV/m smaller
![Page 38: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/38.jpg)
Scaling to CLIC conditions: Scaled from lowest measured BDR to BDR = 4*10-7 and =180 ns(CLIC flat-top is 170 ns), using E 29 5/ BDR = constant assumption
T18 by KEK/SLACat SLAC #1
T18 by KEK/SLACat KEK
T18 by CERNat SLAC
TD18 by KEK/SLACat SLAC
TD18 by KEK/SLACat KEK
Unloaded Gradient [MV/m]
T24 by KEK/SLACat SLAC
1400
3900
550
Total testing time [hr]
1100
3200
200
T18 by KEK/SLACat SLAC #2
280
60 70 80 90 100 110
HOM Damped
HOM Damped
Gradients Achieved at a CLIC-AcceptableBreakdown Rate
![Page 39: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/39.jpg)
High Power (Multi-MW) X-BandApplications
• Short bunch FELs
– Energy Linearizer: in use at LCLS, planned for BNL, PSI,Fermi/Trieste and SPARX/Fascati
– Deflecting Cavity for Bunch Length Measurements
• 100’s of MeV to Many GeV Linacs
– LLNL 250 MeV linac for gamma-ray production
– ELI 600 MeV linac for gamma-ray production
– SLAC 600 MeV energy ‘dither’ linacs for LCLS II
– LANL 6-20 GeV linac for an XFEL source to probe dense matter
– SLAC 250 MeV concept for a proton linac
– SLAC study of a 6 GeV Linac for a Compact XFEL (CXFEL) source
![Page 40: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/40.jpg)
Afte
r BC
1A
fter B
C1
zz ==227227 mm
NonNon--linearity limits compression…linearity limits compression… …and spike drives…and spike drives CSRCSR
z =200 m
X-Band Energy ‘Linearizer’ at LCLS
z = 840 m
energy-timecorrelation
X-Band Structure: 0.6 m long, 20 MV
![Page 41: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/41.jpg)
LLNL 250 MeV X-band Linac forCompton Gamma Ray Production
![Page 42: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/42.jpg)
LANL MaRIE Project: 50 keV XFEL
20 GeV, 70 MV/m X-band Linac(space limited)
![Page 43: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/43.jpg)
Compact Proton Linac for TherapyExamining the use of SW X-band cavities to accelerate protons to 250 MeV
Transit time effects, bunching and aperture size effects are challenging
0 20 40 60 80 100 120 140 160 180 2000
10
20
30
40
50
60
70
80
90
100
25 MeV40 MeV55 MeV70 MeV
Power/m [MW/m]
Ave
rage
Gra
dien
t [M
V/m
]
InjectionEnergy
![Page 44: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/44.jpg)
Four 2 m long C-band structures, 26 MV/m
Total energy gain per modulator = 208 MeV10 m
C-band- Klystron5.7 GHz, 50 MW, 2.5 s, 100 Hz
120 MW0.5 s
40 MW2.5 s
30 MW30 MW
3 dB
3 dB3 dB
30 MW30 MW
SwissFEL Main Linac Building Block
SLEDRF pulse compressor
Hans Braun: “X-band was not considered because no commercial klystrons available”
Recently issued bid to have two vendors each build a 50 MW XL4 klystron
![Page 45: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/45.jpg)
Parameter symbol LCLS CXFEL unitBunch Charge Q 250 250 pCElectron Energy E 14 6 GeVEmittance x,y 0.4-0.6 0.4-0.5 µmPeak Current Ipk 3.0 3.0 kAEnergy Spread E/E 0.01 0.02 %Undulator Period u 3 1.5 cmUnd. Parameter K 3.5 1.9Mean Und. Beta 30 8 mSat. Length Lsat 60 30 mSat. Power Psat 30 10 GWFWHM Pulse Length 80 80 fsPhotons/Pulse N 2 0.7 1012
Compact X-Ray (1.5 Å) FEL
![Page 46: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/46.jpg)
Linac-1250 MeV
Linac-22.5 GeV
Linac-36 GeV
BC1 BC2
UndulatorL = 40 mS
RFGun
X
undulator
LCLS-like injectorL ~ 50 m
250 pC, x,y 0.4 m
X-band Linac Driven Compact X-ray FEL
X X
X-band main linac+BC2G ~ 70 MV/m, L ~ 150 m
Use LCLS injector beam distribution and H60structure (a/ =0.18) after BC1
LiTrack simulates longitudinal dynamics with wakeand obtains 3 kA “uniform” distribution
Similar results for T53 structure (a/ =0.13) with 200pC charge
![Page 47: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/47.jpg)
Units CXFEL NLCBeam Energy GeV 0.25-6 2-250Bunch Charge nC 0.25 1.2RF Pulse Width* ns 150 400Linac Pulse Rate Hz 120 120Beam Bunch Length m 56, 7 110
Operation Parameters
* Allows ~ 50-70 ns multibunch operation
CXFEL wakefield effects are comparable at the upstreamend of the linac as the lower bunch charge and shorter bunchlength offset the lower energy, however the bunch emittance
is 25 times larger
![Page 48: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/48.jpg)
Layout of CXFEL Linac RF Unit50 MW XL4
100 MW1.5 us
400 kV
480 MW150 ns
12 m
Nine T53 Structures (a/ = 13%) or Six H60 Structures (a/ = 18%)
![Page 49: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/49.jpg)
Units T53 H60
Structure Type ConstantE_surface
Detuned
Length cm 0.53 0.6
Filling time ns 74.3 105
Phase Advance/ Cell 2/3 5/6
<a>/ % 13.4 17.9Power Needed for<Ea> = 70 MV/m
MW 48 73
Two Accelerator Structure Types
![Page 50: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/50.jpg)
50 60 70 80 90 1001
1.05
1.1
1.15
1.2
1.25
1.3
1.35
1.4
Gradient (MV/m)
Rel
ativ
e 6G
eV M
L C
ost H60VG3R
T53VG3R
Assuming 1) Tunnel cost 25 k$/m, AC power + cooling power 2.5 $/Watt2) Modulator efficiency 70%, Klystron efficiency 55%.
Gradient Optimization
![Page 51: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/51.jpg)
60 65 70 75 8010
-5
10-4
10-3
10-2
10-1
100
Gradient (MV/m)
Bre
akdo
wn
Rat
e at
150
ns
120
Hz
(#/h
r) H60VG3RT53VG3R
Structure Breakdown Rates with 150 ns Pulses
1) H60VG3R scaled at 0.2/hr for 65 MV/m,400 ns, 60Hz2) T53VG3R scaled at 1/hr for 70 MV/m, 480 ns, 60 Hz3) Assuming BDR ~ G26, ~ PW6
At 70 MV/m,Rate Less
Than1/100hr at
120 Hz
![Page 52: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/52.jpg)
Units T53 H60
Average RF Phase Offset+ Deg 2.6 2.6Power Gain 4.83 4.83
Klystrons per Unit 2 2Acc. Structures per Unit 9 6RF Unit Length (Scaled toNLC)
m 6.75 4.5
Total RF units 18 24Main Linac Length m 122 108Total Linac Length# m 192 178
RF Unit for Two Structure TypesOperating at 70 MV/m*
*Assume 13% RF overhead for waveguide losses+ scaled to NLC for single bunch loading compensation# including ML, 50m injector and 20 m BC2 at 2.5 GeV
![Page 53: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/53.jpg)
Transverse Wake Averaged over aGaussian Bunch
Linac-3
Linac-2
![Page 54: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/54.jpg)
Emittance GrowthStrength parameter:
Emittance growth due toinjection jitter xo if is small:
Chao, Richter, Yao
• For CXFEL, eN= 250 pC, N= .4 m, = 0, and
Linac-2: E0= .25 GeV, Ef= 2.5 GeV, z= 56 m, l= 32 m, 0= 10 m ( x0= 90 m) => = .14
Linac-3: E0= 2.5 GeV, Ef= 6 GeV, z= 7 m, l= 50 m, 0= 10 m ( x0= 29 m) => = .01
• For random misalignment, let x02-> xrms
2/Mp
• lcu= a2/2 z= 1.6 m (Linac-3)—catch-up distance, estimate of distance to steady-state
(for ~ E )
![Page 55: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/55.jpg)
Single Bunch Tolerance Summary
• In both Linac-2 and Linac-3, << 1, => short-range, transversewakefields in H60VG3 are not a major issue in that:
An injection jitter of x0 yields 1% emittance growth in Linac-2 and .003% in Linac-3Random misalignment of 1 mm rms, assuming 50 structuresin each linac, yields an emittance growth of 1% in Linac-2,0.1% in Linac-3
• With the T53VG3R structure, the jitter and misalignmenttolerances are about three times smaller for the sameemittance growth.
• The wake effect is weak mainly because the bunches are veryshort.
![Page 56: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/56.jpg)
5.59 Cell X-band Gun
![Page 57: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/57.jpg)
X-Band Gun Development (with LLNL)
Emittance ~ 0.5 micronfor a 250 pC Bunch,Longitudinal EmittanceLess Than ½ of that atLCLS
Comparison of 4D emittance alongthe gun computed withImpactT (‘instant’ space charge)andPIC 3D (‘delayed’ space chargeplus wakes with true geometry)at two bunch charges and threelaser offsets
![Page 58: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/58.jpg)
Optimization Using Stacked LasersAt NLCTA, will be able to
run short laser pulsesand stack two pulses.
For 250 pC bunches,emittance = 0.3 m(95% particles) withsingle Gaussian (500 fsFWHM) vs 0.25 m(95% particles) withstack of two Gaussians(300 fs FWHM each).
= 0.76 ps
![Page 59: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/59.jpg)
LinacLinac--11250 MeV250 MeV
LinacLinac--222 GeV2 GeVBCBC
XX--BandBandRF GunRF Gun
Xundulatorundulator
X
Linearization Without Higher Harmonic RF
![Page 60: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/60.jpg)
ParameterParameter Sym.Sym. LCLSLCLS XFEL1XFEL1 XFEL2XFEL2 XFEL3XFEL3 unitunitbunch chargebunch charge QQ 250250 2020 120120 250250 pCpCEnergyEnergy EE 1414 0.250.25 0.250.25 0.250.25 GeVGeVN. emittanceN. emittance x,yx,y 0.40.4--0.60.6 TBDTBD TBDTBD TBDTBD µµmmpeak currentpeak current IIpkpk 3.03.0 1.81.8 3.03.0 3.03.0 kAkASlice espreadSlice espread EE/E/E 0.010.01 ~0.1~0.1 ~0.1~0.1 0.10.1 %%FWHMFWHM 8080 1212 3030 5050 fsfs
XFEL1
XFEL2
XFEL3
Adjust R56 and T566 toachieve ~ flat 3 kAbunches
After BC
![Page 61: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/61.jpg)
ParameterParameter Sym.Sym. LCLSLCLS XFEL1XFEL1 XFEL2XFEL2 XFEL3XFEL3 unitunitbunch chargebunch charge QQ 250250 2020 120120 250250 pCpCEnergyEnergy EE 1414 66 66 66 GeVGeVN. emittanceN. emittance x,yx,y 0.40.4--0.60.6 TBDTBD TBDTBD TBDTBD µµmmpeak currentpeak current IIpkpk 3.03.0 1.81.8 3.03.0 3.03.0 kAkASlice espreadSlice espread EE/E/E 0.010.01 0.010.01--0.020.02 0.010.01--0.020.02 0.010.01--0.020.02 %%FWHMFWHM 8080 1212 3030 5050 fsfs
XFEL1
XFEL2
XFEL3
End of Linac
With above Longitudinalwake, adjust rf phase tominimize energy spread
![Page 62: X-Band Technology Overview And Applications · Short-range transverse wakefields small to limit linac emittance growth: iris radius limited to 17% of rf wavelength (i.e. a/ O= 17%)](https://reader031.vdocument.in/reader031/viewer/2022011914/5fc37fb8b5d4652c1b4d7695/html5/thumbnails/62.jpg)
X-Band Revival• The 15 year, ~ 100 M$ development of X-band technology for a
linear collider produced a suite of robust, high power components.
• With the low bunch charge being considered for future XFELs, X-
band technology affords a low cost, compact means of generating
multi-GeV, low emittance bunches.
• Would operate at gradient/power levels already demonstrated.
• Modulators industrialized, klystrons will soon be and waveguide
and structures can be readily built in industry.
• To further simply such a linac, a low emittance X-band gun and