draft 119078x1 t3 system assembly 26.xi.08 version 1
TRANSCRIPT
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
1/54
PAGE 1/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
systEm AssEmbly GuidE
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
2/54
PAGE 2/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
Draftversion
Forinternalr
eviewonly
TANDBERG WORLD HEADQUARTERS
Philip Pedersens vei 20
1366 Lysaker, Norway
Tel: +47 67 125 125
Fax: +47 67 125 234
Video: +47 67 126 126
E-mail: [email protected]
1212 Avenue o the Americas
24th Floor
New York, NY U.S.A. 10036
Tel: +1 212 692 6500
Fax: +1 212 692 6501
Video: +1 212 692 6535
E-mail: [email protected]
www.tandberg.com
This document is condential and remains proprietary to Tandberg Telecom AS (Tandberg).
Without Tandbergs prior written approval, this document, either in whole or in part, may
not be reproduced in any orm or by any means, disclosed to others outside the Clients
organisation or used or any purpose whatsoever other than or evaluatory purposes by the
Client.
All inormation, descriptions, examples and calculations contained in this document are or
guidance purposes only and should not be treated as denitive.
Whilst all reasonable care has been taken to ensure that the inormation contained in the
presentation is accurate and not misleading, Tandberg shall not be liable or any loss resulting
rom reliance placed on the inormation contained in this document.
imPortAnt informAtion rEGArdinG room dimEnsions
The inormation contained in this document applies to an optimally sized
immersive room. For rooms o other dimensions, the inormation in this
document should be regarded as guidelines only and dimension inormationshould be adapted accordingly, wherever applicable.
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
3/54
PAGE 3/54
TANDBERG
Telepresence T3
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
Draftversion
Forinternalr
eviewonly
systEm AssEmbly GuidE
Ceiling lights ...........................................................................................................4
Table foor structure ................................................................................................5
Bottom modules ...................................................................................................11
Table column assembly ........................................................................................16
Floor cabling structure ..........................................................................................17
Cable bundling structure in foor...........................................................................18
Mounting the column tray ....................................................................................19
Mounting the monitor assemblies........................................................................20
Mounting the camera ...........................................................................................23
Cable connection detailssystem connections ...................................................25
System cabling structure ......................................................................................26
Cabling bundling in the systems...........................................................................27
System cable connections let system .................................................................29
System cable connections center system ............................................................30
System cable connections right system ...............................................................31
Table top module ..................................................................................................32
Cable connection detailstable connections .......................................................36
Table cabling structure ..........................................................................................37
Cabling bundling in the table ................................................................................38
Table cable connections let system.....................................................................42
Table cable connections center system................................................................43
Table cable connections right system...................................................................44
Table connection notes .........................................................................................45
Mounting the TCU ................................................................................................46
This document shows the assembling o
the TANDBERG T3 system.
Reerences to let, center and right parts
are shown in illustration below.
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
4/54
PAGE 4/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
CEilinG liGhts
Unpack the box marked Main Lighting T3. The box contains the Telepresence
T3 Ceiling lighting modules.
The rear ceiling lighting consists o seven 640 mm spot light armatures
mechanically astened together and parallel wired together. Recommended
positioning or the rear ceiling lighting are rear edge 5 cm / 2 rom the inner rear
wall and 228 cm / 7 5 34 rom the foor. )
The ront ceiling lighting consists o our 450 mm spot light armatures plus three
fuorescent light armatures mechanically astened together and parallel wired
together. Recommended positioning or the ront ceiling lights is rear edge
200 cm / 6 6 710 rom inner rear wall and bottom edge 228 cm / 7 5 34 rom thefoor).
Ceiling attachment by means o hang wires provided with lighting. Anchor
method in ceiling will depend on ceiling structure and composition. You may
want to consult an architect or building engineer to dene the suitable mounting
method.
The lights are to be connected to a switch as described in the document
TANDBERG Telepresence T3Room Installation Guide.
Power supply requirements can be ound in the document TANDBERG
Telepresence T3Room Requirements.
228 cm7 5 34
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
5/54
PAGE 5/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
tAblE floor struCturE
Unpack the box marked T3 Table Floor Structure and brackets. The box contains
the parts shown in the below Fig.
Gently unpack the cover plates and place them in the lid o the box, with the
packaging oam to ensure they are not damaged.
Ca! Make sure power is disconnected
beore any cables are connected or
disconnected.
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
6/54
PAGE 6/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
d a w:
1. Begin by placing the bottom rame center centered on the foor, appr.
4198 mm (13 9 310) rom the rear (white) wall. The distance between the
white and the blue wall is 140 mm (5)
tAblE floor struCturE
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
7/54
PAGE 7/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
2. Unpack the bag containing screws, nuts and plates. Contents should be as
ollows:
Rubb
er
mould
ing
2Shi
msplat
e
2Joining
plate
38 pcs M6 nut (a)
36 pcs M8 nut (b)
62 pcs M610 (c)
32 pcs M48 (d)
6 pcs M412 ()
12 pcs M1030 (e)
3. Then place the Bottom frame righton the right side o the Bottom frame
center. Fasten with 4 pcs. o nut (a). Repeat or let side.
tAblE floor struCturE
8 nut (a) M6
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
8/54
PAGE 8/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
4. Please make sure that the distance to the wall is constant. I necessary, mark
the position with a piece o tape or similar.
5. Remove the protective lm along the edges on the Coverplate center(high-
lighted in picture). Repeat or the other two coverplates.
6. Fasten the Coverplate centerto the coverplate front left, using the Joining
plateand the Shims plate.
tAblE floor struCturE
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
9/54
PAGE 9/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
7. Fasten with 2 pcs o the M412 screw ()
8. Repeat on the right side, with the right cover plate.
tAblE floor struCturE
6 screw () M412
2 nut (a) M6
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
10/54
PAGE 10/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
9. When the three plates have been mounted together, gently sink them onto
the foor structure.
tAblE floor struCturE
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
11/54
PAGE 11/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
1. Unpack the let system and take out the let Bottom module. Dismount the
top screw on the right side in addition to the cable hatch cover.
2. The ollowing cables must be disconnected and removed:
112083 Ethernet Cable
112980 Power Cable (main in)
115233 PC Connection Cable (Video/audio in)
117083 Main Speaker Cable (top o amplier)
117087 Monitor Control Cable (USB-DSUB)
118315 External Microphone Cable
117084 Audio RCA Cable (Codec to amplier).
3. Fasten by astening 4 nuts (b).
bottom modulEs
4 nut (b) M8
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
12/54
PAGE 12/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
bottom modulEs
4 nut (b) M8
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
13/54
PAGE 13/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
4. Unpack the center system. Dismount the top screw and the cable hatch
cover on both sides o the module.
5. In addition, disconnect and put away the ollowing cables:
112083 Ethernet Cable
112980 Power Cable (main in)
115233 PC Connection Cable (Video/audio in)
117083 Main Speaker Cable (top o amplier)
117087 Monitor Control Cable (USB-DSUB)
118315 External Microphone Cable
ne! The 117084 Audio RCA Cable (Codec to amplier).shall be retained or the
Center module. d eve cae!
6. Mount the Center bottom moduleto the foor structure.
bottom modulEs
4 nut (b) M8
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
14/54
PAGE 14/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
7. Unpack the right Bottom module. Dismount the top screw and the cable
hatch cover on the let side o the module, in addition to the same cables
which were disconnected in the Left module, i.e.:
112083 Ethernet Cable
112980 Power Cable (main in)
115233 PC Connection Cable (Video/audio in)
117083 Main Speaker Cable (top o amplier)
117087 Monitor Control Cable (USB-DSUB)
118315 External Microphone Cable
117084 Audio RCA Cable (Codec to amplier)
8. Mount the right Bottom module.
Observe that the bottom modules can be opened completely. When you do the
cabling we recommend that you open the center module completely and the let
and right modules partly.
bottom modulEs
4 nut (b) M8
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
15/54
PAGE 15/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
9. Unpack the T3 Brackets Kit, contents should be as ollows:
10. For the let Bottom module, get the splitter brackets shown above. Fasten
them using 3 pcs M6 fange nuts as shown below. Then place the HDMI
splitter between the brackets.
SplitterBracketbig
SplitterBracketsmall
11. Repeat or the right Bottom module.
6 fange nut
bottom modulEs
te T3 Brackets kitc :
g: 28 Screw M4 12 (Pan)
: 4 Screw M4 40
: 6 Nut M6 (fange type)
j: 2 Module Angle Plates
k: 8 Nut Plates
: 2 Splitter Brackets big
: 2 Splitter Brackets small
: 2 Cable Channels
: 3 Monitor brackets
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
16/54
PAGE 16/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
tAblE Column AssEmbly
Unpack the box marked Table column Assembly
ne! The Column coversand the Door coversshall not be mounted yet, so
please place them in a spot where they wont be damaged.
1. Mount the columns using 12 nut b or each column, but make sure that
only the two outer nuts are astened at this point. Screw only nger-tight.
4 nut (b) M8
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
17/54
PAGE
17/54
TANDBERG
TelepresenceT3
119078.X1TELEPRESENCET3SYSTEMASSEMBLY11.08
floor
CA
blinGs
truCtu
rE
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
18/54
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
19/54
PAGE 19/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
mountinG thE Column trAy
Slide the Column trayinto place as shown below. The column tray is ound in the
box marked T3 Table Floor Structure and brackets.
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
20/54
PAGE 20/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
1. Unpack the monitor assembly and lit onto the bottom module. It requires a
minimum o our persons to lit the assembly, using the attached straps and
gloves.
mountinG thE monitorAssEmbliEs
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
21/54
PAGE 21/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
2. Unscrew the top side screw o the monitor assembly on the right side o the
let module, both sides o the center module and the let side o the right
module.
3. Put the Center-and the Right monitor assembliesin place.
4. In order to level the systems, use 4 pcs o the e screw in the holes marked
in the picture below. Note that the picture illustrates the bottom module as
seen rom above, with the door open.
mountinG thE monitorAssEmbliEs
12 screw (e)
M1030
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
22/54
PAGE 22/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
5. Unpack the 2 angle plates and the 8 nut plates rom the box marked T3
Table Floor Structure and brackets. asten with screws through the holes on
top side on the monitors and the bottom modules. The short screw at the
monitor top and the long screw at the bottom module top. Use the nut plates
inside the angle plate. Note that the top cover and the door must be opened
in order to do so.
mountinG thE monitorAssEmbliEs
4 M4 40
4 M4 12
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
23/54
PAGE 23/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
d a w:
1. Open the top cover.
2. Locate the camera cable.
3. Hold the camera upside down.
4. Connect the HDMI and RJ45 connectors o the camera cable.
RJ45 HDMI
Mounting hole (Tripod)1/4" UNC
116606 rev.06RevS/N
www.tandberg.com/recycling
( )
MadeinNorway
( )
PrecisionHD1080p
TTC8-02
2 0 0 0 0 0 0 0 0 1 1 1
Videoformat
3 0 0 0 0 1 1 1 1 0 0 0
4 0 0 1 1 0 0 1 1 0 0 1
1 0 0 0 0 0 0 0 0 0 0 0
5
HD-SDI
0
Auto*
1
1080p25
0
1080p30
1
1080p50
0
1080p60
1
720p25
0
720p30
1
720p50
0
720p60
1
480p60
0
SWc
ontrol**
1080p25
1080p30
720p50
720p60
720p25
720p30
720p50
720p60
480p60
1 0HDMI
*CameranegotiatesformatoverHDMI,HD-SDItracks
HDMI,anddefaultsto1080p30inabsenceofHDMIsync.
**Pleaseconsultmanual.
HDMIRJ45
5. Careully slide the camera into place.
mountinG thE CAmErA
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
24/54
PAGE 24/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
6. Locate the other end o the camera cable mounted to the monitor. Use the
cable clamps to asten the cable inside the bottom module and connect to
the codec.
l
l
l l l
l
lCamera cable goes
inside the channel
7. Connect to the codec as shown.
Li i
---
---------
l
ll ll
l l -
l l +
---
---------
l
ll ll
l l -
l l +
Li i
---
---------
l
ll ll
l l -
l l +
---
---------
l
ll ll
l l -
l l +
8. Shut the top cover and mount the cover and the loudspeaker grille as shown.
mountinG thE CAmErA
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
25/54
PAGE 25/54
TANDBERG
Telepresence T3
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
Draftversion
Forinternalr
eviewonly
The above is a complete drawing o the total cabling. This document is available separately as a ull size drawing. For
your convenience the connection details or each component in the systems (upper part o this Fig.) are presented on the
ollowing pagesimmediately ater the system cable bundling kits listings..
CAblE ConnECtion dEtAilssystEm ConnECtions
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
26/54
PAGE
26/54
TANDBERG
TelepresenceT3
119078.X1TELEPRESENCET3SYSTEMASSEMBLY11.08
systEmC
AblinGs
truCt
urE
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
27/54
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
28/54
PAGE
28/54
TANDBERG
TelepresenceT3
119078.X1TELEPRESENCET3SYSTEMASSEMBLY11.08
f
Kn.
dawg
eeece
A.
bgecp
[old
ecp]
f/evce
f/
evce
(makgeve)
119070
10
117831
117833
117836
117838
117842
117923
118592
CableDVI-DHDMI
CableHDMIHDMI
CableRCARCA
CableRCARCA
CableHDMIHDMI
CableRCARCA
CableRJ45RJ45
Codec
LCodecC
Codec
LCodecC
Codec
LCodecC
Codec
LCodecC
Codec
LCodecC
DNAM
Lcable117854
Codec
LCodecC
(CodecLetcodecmain)
(CodecLetcodecmain)
(CodecLetcodecmain)
(CodecLetcodecmain)
(CodecLetcodecmain)
(DNAMLetcable117
854)
(CodecLetcodecmain)
11
117834
117835
117837
117839
117841
117843
117924
118591
CableHDMIHDMI
CableHDMIHDMI
CableRCARCA
CableRCARCA
CableDVI-DHDMI
CableHDMIHDMI
CableRCARCA
CableRJ45RJ45
Codec
CCodecR
Codec
CCodecR
Codec
CCodecR
Codec
CCodecR
Codec
CPresentationSplitterR
Codec
CCodecR
Cable117854DNAML
Codec
CCodecR
(Codecmaincodecright)
(Codecmaincodecright)
(Codecmaincodecright)
(Codecmaincodecright)
(Codecmainmodulerightsplitter)
(Codecmaincodecright)
(Cable117854DNAM
Right)
(Codecmaincodecright)
12
117850
117853
Cable15pDSUB15pDSUB
CableHDMIHDMI
DNAM
LMainVideoDisplayL
Codec
LPresentationSplitterL
(DNAMLetDisplayVideoLet)
(CodecletModuleletsplitter)
13
117852
117854
Cable15pDSUB15pDSUB
CableRCASplit
DNAM
CMainVideoDisplayC
Codec
CCable117923/117924
(DNAMmainDisplayv
ideomain)
(CodecmainCable117923/117924)
14
117856
117858
Cable15pDSUB15pDSUB
CableHDMIHDMI
DNAM
RMainVideoDisplayR
Codec
RPresentationSplitterR
(DNAMRightDisplayvideoRight)
(Codecrightmodulerightsplitter)
15
117860
CableHDMIHDMI
Presen
tationSplitterLPresentationSplitterR
(Moduleletsplittermodulerightsplitter)
CAblinGb
un
dlinGi
nt
hEsy
stEms
Placecablekits1015inthesystemsaccordingtocorrespond
inggureSystemcablingstructure.Thenumbers1015matchthecablekits1015:
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
29/54
PAGE
29/54
TANDBERG
TelepresenceT3
119078.X1TELEPRESENCET3SYSTEMASSEMBLY11.08
sy
stEmC
AblE
Co
nnECtions
lEftsystEm
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
30/54
PAGE
30/54
TANDBERG
TelepresenceT3
119078.X1TELEPRESENCET3SYSTEMASSEMBLY11.08
sy
stEmC
AblE
Co
nnECtions
CEntEr
systEm
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
31/54
PAGE
31/54
TANDBERG
TelepresenceT3
119078.X1TELEPRESENCET3SYSTEMASSEMBLY11.08
sy
stEmC
AblE
Co
nnECtions
riG
htsystEm
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
32/54
PAGE 32/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
Careully unpack the box labeled T3 Table Top Module, where the ollowing
items are ound:
Table top tightener and wooden plugs
Table top assembly let, center and right
Table top
tightener and
wooden plugs
Table top
assembly let
Table top
assembly center
Table top
assembly right
d a w:
1. Mount the Left table topto the column by astening nuts and screws on the
underside o the table top. Please keep the protective oam and sheet on the
table top to prevent it rom being damaged.
tAblE toP modulE
8 screw (c) M610
12 nut (a) M6
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
33/54
PAGE 33/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
tAblE toP modulE
2. Fasten the wooden plugs in the sides o the let table top.
3. Lit Table top centerand slide the steel proles into the Table top left.
4. Lit the Table top assembly centerso that the Right assemblycan slide on
the Center assembly, above the Right column. Whilst doing so, the Left
column tilts, which is why the screws shall not be astened.
5. Drop the right table top assembly to the column and asten.
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
34/54
PAGE 34/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
tAblE toP modulE
6. Fasten three screws (c) in each joint o the table tops.
7. Tighten all screw and nuts, including the remaining ones between the col-
umns and the rame.
8 screw (c) M610
12 nut (a) M6
6 screw (c) M610
20 nut (b)
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
35/54
PAGE 35/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
8. Fit the two Table tightenersand tighten to remove the gap between the table
top plates.
9. Find the Cable channelsand insert them in the hole o the center table top,
slide them out to let and right, respectively. The cable channels must be
astened with a screw c each.
10. Mount all the cables in the table as shown on the ollowing pages.
tAblE toP modulE
2 screw (c)
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
36/54
PAGE 36/54
TANDBERG
Telepresence T3
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
Draftversion
Forinternalr
eviewonly
The above is a complete drawing o the total cabling. This document is available separately as a ull size drawing. For your
convenience the connection details or each component in the table (lower part o this Fig.) are presented on the ollowing
pagesimmediately ater the table cable bundling kits listings.
CAblE ConnECtion dEtAilstAblE ConnECtions
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
37/54
PAGE
37/54
TANDBERG
TelepresenceT3
119078.X1TELEPRESENCET3SYSTEMASSEMBLY11.08
tAblECA
blinGs
truCtu
rE
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
38/54
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
39/54
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
40/54
PAGE
40/54
TANDBERG
TelepresenceT3
119078.X1TELEPRESENCET3SYSTEMASSEMBLY11.08
CAblinGb
u
ndlinGi
nt
hE
tAblE
Placecablekits1
015inthesystemsaccordingtocorrespondinggureTablecablingstructure.Th
enumbers1624matchthecablekits16
24
f
K
n.
dawg
eeece
A.
bgecp
[old
ecp]
f/
evce
f/
evce
(makgeve
)
119
070
20
117832
117872
CableD
VI-DHDMI
Cable9
pDSUB9pDSUB
TouchCollaborationDisplaySplitterCable117857
PresentationInputSwitchTelepresenceControlUnit
(SplitterTeccable117857)
(SwitchPCinPresTecPC)
21
117805
117814
117815
117820
117821
CableH
DMIHDMI
CableV
GAVGA
CableV
GAVGA
Cable3
,5[mm]plugSinglewires
Cable3,5[mm]plugSinglewires
TouchCollaborationDisplayLTouchCollaborationDisplaySplitter
PCConnectivityL1PresentationInputSwitch
PCConnectivityL2PresentationInputSwitch
PCConnectivityL1PresentationInputSwitch
PCConnectivityL2PresentationInputSwitch
(DisplayPresLetSplitterTec)
(PresLet3switchPCin
pres)
(PresLet2switchPCin
pres)
(PresLet3switchPCin
pres)
(Preslet2switchPCinpres)
22
117813
117864
117885
117886
CableU
SBAUSBB
Cable9
pDSUB9pDSUB
CableR
J45RJ45
CableR
J45RJ45
Telepresenc
eControlUnitTouchCollaborationDispla
yR
Telepresenc
eControlUnitTouchCollaborationDispla
yR
Telepresenc
eControlUnitPCConnectivityR1
Telepresenc
eControlUnitPCConnectivityR2
(TecPCdisplaypresright)
(TecPCdisplaypresright)
(TecPCpresright2)
(TecPCpresright3)
23
117873
117892
CableR
J45RJ45
CableP
owerMaleFemale
Telepresenc
eControlUnitTelepresenceControlUnit
PowerDistributionBlock1TelepresenceControlUnit
(TecPCTecPC)
(Splitter1TecPC)
24
117893
117894
CableP
owerMaleFemale
CableP
owerMaleFemale
PowerDistributionBlock3PresentationInputSwitch
PowerDistributionBlock3TouchCollaborationDisplaySplitter
(Splitter3switchpcinpres)
(Splitter3splittertec)
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
41/54
PAGE
41/54
TANDBERG
TelepresenceT3
119078.X1TELEPRESENCET3SYSTEMASSEMBLY11.08
f
Kn
.
dawg
eeece
A.
bgecp[oldecp
]
f/
evce
f/
evce(makgeve)
118914
A
117920
Cable9pDSUB9pDSUB
TableQuickButtonsLTableQuick
ButtonsC
(SSTBLetSSTBMain)
B
117921
Cable9pDSUB9pDSUB
TableQuickButtonsCTableQuick
ButtonsR
(SSTBMainSSTB
Right)
C
117874
Cable9pDSUB9pDSUB
TelepresenceControlUnitTableQuickButtonsL
(TecPCSSTBLet)
D
118555
118544
118545
118546
118547
118548
CableMicrodotMicrodot
CableMicrodotMicrodot
CableMicrodotMicrodot
CableMicrodotMicrodot
CableMicrodotMicrodot
CableMicrodotMicrodot
MicL1MicroDottoXLRadapterM
icL1
MicL2MicroDottoXLRadapterM
icL2
MicC1MicroDottoXLRadapterM
icC1
MicC2MicroDottoXLRadapterM
icC2
MicR1MicroDottoXLRadapterM
icR1
MicR2MicroDottoXLRadapterM
icR2
118048
E
117857
CableDMS-59DVIsplit
TelepresenceControlUnitCable111732
(TecPCCable111
732)
CAblinGb
u
ndlinGi
nt
hEtAblE
Place
ollowingcables(useArt.No.ForID)accordingtonumbersAEonthegu
reTableCablingStructure
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
42/54
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
43/54
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
44/54
PAGE
44/54
TANDBERG
TelepresenceT3
119078.X1TELEPRESENCET3SYSTEMASSEMBLY11.08
tA
blECAblE
Co
nnECtions
riG
htsystEm
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
45/54
PAGE 45/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
ne that when connecting the serial cable
117872, a KRAMER Null-modem adaptermust
be inserted between the cable and the panel
socket.
tAblE ConnECtion notEs
Audio CAblE ConnECtions
Input connections:
Cables Nos.117820117825:
Red wire to Let (+) on the switch
Black (GND) to Let () on the switch
White wire to Right (+) on the switch
Use a short cable to connect the two ()
together
Output connections:
Cable Nos. 117828 (Let) and 117829 (Right):
Pin 1 to GND black
Pin 2 to + RED
Pin 3 to YELLOW
null-modEm rEquirEmEnt
R
L G
G
+
+
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
46/54
PAGE 46/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
mountinG thE tCu
1. Unpack the box marked with T3 Telepresence kit w/ TCU & screens where
the ollowing items are ound:
3 Table Quick Buttons with
power supply and cable kit
3 Touch Collaboration Display
(22) with power supply
6 Cable Well Assemblies
2. Fasten the monitors to the monitor brackets using 8 c screws or each moni-
tor. Switch on the monitors.
24 screw (c)
ne! The table must have all cables
mounted beore the presentation
screens are installed.
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
47/54
PAGE 47/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
3. Fasten screws (c) in the opening o the table as shown below.
4. Connect all the cables to the monitorsee the cable schematics.
se e pwe wc on. ne a ca e e ae e
cee ave ee ae.
5. Sink the monitors onto the screws and tighten.
mountinG thE tCu
36 screw (c)
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
48/54
PAGE 48/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
6. While holding the Cable well, thread the power, audio, VGA and ethernet
cables into the opening o the well. Fasten the cables with the cable clamp
so that appr. 80cm o the cables are let outside.
7. Sink the cable wells onto the premounted screws. Fasten the screws and
close the lid. I the lid is not fush with the table top, loosen the screws and
adjust the cable wells. Then asten the screws again.
mountinG thE tCu
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
49/54
PAGE 49/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
8. Mount the covers A and B or the cable well.
9. Find the Table quick buttonsmodules and make sure to congure the small
switches ound in the back. Congure according to the diagram shown on
the label. (The let module shall have its let and right switches on, the center
module shall have its let switch on and its right o, the right module shallhave its let switch o and its right on).
Plug the power into the Table quick buttonsmodule.
mountinG thE tCu
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
50/54
PAGE 50/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
10. Connect the D-SUB cables to the SSTB, the microphone cables to the micro-
phone and place it in on top o the bracket. The SSTB is astened and height
adjusted (to make it fush with the table) by means o two screwsone rom
each cable well.
mountinG thE tCu
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
51/54
PAGE 51/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
11. Unscrew the screws holding the brackets (marked in orange in picture be-
low) in the let column.
12. Find the TCU in the box marked T3 Telepresence kit w/ TCU & screens and
asten the TCU to the let column, using the bracket and the same screws as
were just loosened. (The TCU is marked in green in the picture below). Con-
nect the cables to the TCU.
13. Unscrew the screws holding the bracket in the right Column. Switch on the
Presentation input switch beore mounting. Make sure the DIP switch is set
correctly: 1: o, 2: o, 3: o, 4: o, 5: o, 6: o, 7: o, 8: o
Fasten it in the same manner as the TCU was astened.
mountinG thE tCu
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
52/54
PAGE 52/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
14. Place the cover plates let and right on top o the foor structure.
mountinG thE tCu
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
53/54
PAGE 53/54
119078.X1 TELEPRESENCE T3 SYSTEM ASSEMBLY 11.08
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
4 screw ()
M412
15. Fasten the End cover platesto the Leftand Right cover plates, using 2
screws or each plate.
16. Fold the column cover around the column and asten with 4 c screws on
each column
mountinG thE tCu
-
8/3/2019 Draft 119078X1 T3 System Assembly 26.XI.08 Version 1
54/54
TANDBERG
Telepresence T3
Draftversion
Forinternalr
eviewonly
17. Snap the Door coversinto place.
mountinG thE tCu