draft antenna swf integrated pole base …...replacement carlyle streetlight pole with pole base...

4
REVISION & DATE DRAWING NO. ARLINGTON COUNTY, VIRGINIA DEPARTMENT OF ENVIRONMENTAL SERVICES V I R G I N I A A R L I N G T O N SMALL WIRELESS FACILITY (SWF) SWF-01 REPLACEMENT COBRA STREETLIGHT POLE WITH POLE BASE EQUIPMENT CABINET (NON-COUNTY STANDARD) DRAFT

Upload: others

Post on 11-Jan-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DRAFT ANTENNA SWF INTEGRATED POLE BASE …...replacement carlyle streetlight pole with pole base equipment cabinet (non-county standard) draft. knockout plugs for 12', 14' & 16' pole

REVISION & DATE

DRAWING NO.

ARLINGTON COUNTY, VIRGINIADEPARTMENT OF ENVIRONMENTAL SERVICES

V I R G I N I AA R L I N G T O N

SMALL WIRELESS FACILITY (SWF)

SWF-01

REPLACEMENT COBRA STREETLIGHT POLE WITH POLE BASE EQUIPMENT CABINET(NON-COUNTY STANDARD)

DRAFT

AutoCAD SHX Text
NOTES: 1. THIS DETAIL IS NOT TO SCALE AND IS FOR THIS DETAIL IS NOT TO SCALE AND IS FOR REFERENCE PURPOSES ONLY AND SHALL NOT BE USED FOR CONSTRUCTION. 2. SWF VENDOR SHALL SUBMIT DETAIL DESIGN OF SWF VENDOR SHALL SUBMIT DETAIL DESIGN OF REPLACEMENT POLE(S) AND FOUNDATIONS(S) SEALED BY LICENSED PROFESSIONAL ENGINEER IN THE STATE OF VIRGINIA FOR COUNTY'S REVIEW. SWF VENDOR SHALL ALSO FIELD VERIFY AND INDICATE THE AVAILABILITY OF VERTICAL CLEARANCE OF FOUNDATION(S) ON THEIR DESIGN. 3. REPLACEMENT POLE(S) SHALL BE ROUND REPLACEMENT POLE(S) SHALL BE ROUND TAPERED & BLACK FINISHED (SIMILAR TO ARL. CO. STD. TRAFFIC SIGNAL POLE), MAXIMUM 30' IN HEIGHT (INCLUDING SWF ATTACHMENTS) FROM FINISHED GRADE AND NOT TO EXCEED 18" DIAMETER. 4. ALL SWF WIRING SHALL BE LOCATED INSIDE A ALL SWF WIRING SHALL BE LOCATED INSIDE A CONDUIT AND CONDUIT SHALL NOT BE MOUNTED OUTSIDE OF EXISTING STREETLIGHT POLE(S).
AutoCAD SHX Text
ANTENNA
AutoCAD SHX Text
SWF INTEGRATED POLE BASE EQUIPMENT CABINET
AutoCAD SHX Text
DE POWER METER
Page 2: DRAFT ANTENNA SWF INTEGRATED POLE BASE …...replacement carlyle streetlight pole with pole base equipment cabinet (non-county standard) draft. knockout plugs for 12', 14' & 16' pole

REVISION & DATE

DRAWING NO.

ARLINGTON COUNTY, VIRGINIADEPARTMENT OF ENVIRONMENTAL SERVICES

V I R G I N I AA R L I N G T O N

SMALL WIRELESS FACILITY (SWF)

SWF-02

REPLACEMENT COBRA STREETLIGHT POLE (NON-COUNTY STANDARD)

DRAFT

AutoCAD SHX Text
NEW JUNCTION BOX TO BE INSTALLED BY VENDOR
AutoCAD SHX Text
NOTES: 1. THIS DETAIL IS NOT TO SCALE AND IS FOR THIS DETAIL IS NOT TO SCALE AND IS FOR REFERENCE PURPOSES ONLY AND SHALL NOT BE USED FOR CONSTRUCTION. 2. SWF VENDOR SHALL SUBMIT DETAIL DESIGN OF SWF VENDOR SHALL SUBMIT DETAIL DESIGN OF REPLACEMENT POLE(S) AND FOUNDATIONS(S) SEALED BY LICENSED PROFESSIONAL ENGINEER IN THE STATE OF VIRGINIA FOR COUNTY'S REVIEW. SWF VENDOR SHALL ALSO FIELD VERIFY AND INDICATE THE AVAILABILITY OF VERTICAL CLEARANCE OF FOUNDATION(S) ON THEIR DESIGN. 3. REPLACEMENT POLE(S) SHALL BE ROUND REPLACEMENT POLE(S) SHALL BE ROUND TAPERED & BLACK FINISHED (SIMILAR TO ARL. CO. STD. TRAFFIC SIGNAL POLE) AND NOT TO EXCEED 18" DIAMETER. 4. ALL SWF WIRING SHALL BE LOCATED INSIDE A ALL SWF WIRING SHALL BE LOCATED INSIDE A CONDUIT AND CONDUIT SHALL NOT BE MOUNTED OUTSIDE OF EXISTING STREETLIGHT POLE(S).
AutoCAD SHX Text
SWF EQUIPMENT CABINET (LOCATION OPTIONAL)
AutoCAD SHX Text
ANTENNA
AutoCAD SHX Text
30' MAX. HT. ROUND TAPERED & BLACK FINISHED REPLACEMENT POLE
AutoCAD SHX Text
EXISTING COUNTY STREETLIGHT CABLES
AutoCAD SHX Text
SWF CABLES
AutoCAD SHX Text
REPLACEMENT STREETLIGHT FOUNDATION DETAIL VARIES PER MANUFACTURERS' RECOMMENDATIONS
AutoCAD SHX Text
COUNTY STREELIGHT CABLES
AutoCAD SHX Text
SWF EQUIPMENT (LOCATION OPTIONAL)
AutoCAD SHX Text
DE POWER METER
AutoCAD SHX Text
DISCONNECT BOX
Page 3: DRAFT ANTENNA SWF INTEGRATED POLE BASE …...replacement carlyle streetlight pole with pole base equipment cabinet (non-county standard) draft. knockout plugs for 12', 14' & 16' pole

REVISION & DATE

DRAWING NO.

ARLINGTON COUNTY, VIRGINIADEPARTMENT OF ENVIRONMENTAL SERVICES

V I R G I N I AA R L I N G T O N

SMALL WIRELESS FACILITY (SWF)

SWF-03

REPLACEMENT CARLYLE STREETLIGHT POLE WITH POLE BASE EQUIPMENT CABINET(NON-COUNTY STANDARD)

DRAFT

AutoCAD SHX Text
KNOCKOUT PLUGS FOR 12', 14' & 16' POLE MOUNTED DOUBLE CARLYLE
AutoCAD SHX Text
REPLACEMENT STREETLIGHT POLE
AutoCAD SHX Text
DOUBLE CARLYLE LUMINAIRE
AutoCAD SHX Text
SWF INTEGRATED POLE BASE EQUIPMENT CABINET
AutoCAD SHX Text
NOTES: 1. THIS DETAIL IS NOT TO SCALE AND IS FOR THIS DETAIL IS NOT TO SCALE AND IS FOR REFERENCE PURPOSES ONLY AND SHALL NOT BE USED FOR CONSTRUCTION. 2. SWF VENDOR SHALL SUBMIT DETAIL DESIGN OF SWF VENDOR SHALL SUBMIT DETAIL DESIGN OF REPLACEMENT POLE(S) AND FOUNDATIONS(S) SEALED BY LICENSED PROFESSIONAL ENGINEER IN THE STATE OF VIRGINIA FOR COUNTY'S REVIEW. SWF VENDOR SHALL ALSO FIELD VERIFY AND INDICATE THE AVAILABILITY OF VERTICAL CLEARANCE OF FOUNDATION(S) ON THEIR DESIGN. 3. REPLACEMENT POLE(S) SHALL BE ROUND REPLACEMENT POLE(S) SHALL BE ROUND TAPERED & BLACK FINISHED, MAXIMUM 24' IN HEIGHT (INCLUDING SWF ATTACHMENTS) FROM FINISHED GRADE AND NOT TO EXCEED 18" DIAMETER. 4. ALL SWF WIRING SHALL BE LOCATED INSIDE A ALL SWF WIRING SHALL BE LOCATED INSIDE A CONDUIT AND CONDUIT SHALL NOT BE MOUNTED OUTSIDE OF EXISTING STREETLIGHT POLE(S).
AutoCAD SHX Text
ANTENNA
AutoCAD SHX Text
SPACE FOR SWF EQUIPMENT
AutoCAD SHX Text
DE POWER METER
Page 4: DRAFT ANTENNA SWF INTEGRATED POLE BASE …...replacement carlyle streetlight pole with pole base equipment cabinet (non-county standard) draft. knockout plugs for 12', 14' & 16' pole

REVISION & DATE

DRAWING NO.

ARLINGTON COUNTY, VIRGINIADEPARTMENT OF ENVIRONMENTAL SERVICES

V I R G I N I AA R L I N G T O N

SMALL WIRELESS FACILITY (SWF)

SWF-04

REPLACEMENT CARLYLE STREETLIGHT POLE WITH POLE BASE EQUIPMENT CABINET(NON-COUNTY STANDARD)

DRAFT

AutoCAD SHX Text
KNOCKOUT PLUGS FOR 12', 14' & 16' POLE MOUNTED DOUBLE CARLYLE
AutoCAD SHX Text
REPLACEMENT STREETLIGHT POLE
AutoCAD SHX Text
DOUBLE CARLYLE LUMINAIRE
AutoCAD SHX Text
SWF INTEGRATED POLE BASE EQUIPMENT CABINET
AutoCAD SHX Text
NOTES: 1. THIS DETAIL IS NOT TO SCALE AND IS FOR THIS DETAIL IS NOT TO SCALE AND IS FOR REFERENCE PURPOSES ONLY AND SHALL NOT BE USED FOR CONSTRUCTION. 2. SWF VENDOR SHALL SUBMIT DETAIL DESIGN OF SWF VENDOR SHALL SUBMIT DETAIL DESIGN OF REPLACEMENT POLE(S) AND FOUNDATIONS(S) SEALED BY LICENSED PROFESSIONAL ENGINEER IN THE STATE OF VIRGINIA FOR COUNTY'S REVIEW. SWF VENDOR SHALL ALSO FIELD VERIFY AND INDICATE THE AVAILABILITY OF VERTICAL CLEARANCE OF FOUNDATION(S) ON THEIR DESIGN. 3. REPLACEMENT POLE(S) SHALL BE ROUND REPLACEMENT POLE(S) SHALL BE ROUND TAPERED & BLACK FINISHED, MAXIMUM 24' IN HEIGHT (INCLUDING SWF ATTACHMENTS) FROM FINISHED GRADE AND NOT TO EXCEED 18" DIAMETER. 4. ALL SWF WIRING SHALL BE LOCATED INSIDE A ALL SWF WIRING SHALL BE LOCATED INSIDE A CONDUIT AND CONDUIT SHALL NOT BE MOUNTED OUTSIDE OF EXISTING STREETLIGHT POLE(S).
AutoCAD SHX Text
ANTENNA
AutoCAD SHX Text
SPACE FOR SWF EQUIPMENT
AutoCAD SHX Text
NEW JUNCTION BOX TO BE INSTALLED BY VENDOR
AutoCAD SHX Text
COUNTY STREELIGHT CABLES
AutoCAD SHX Text
DE POWER METER
AutoCAD SHX Text
DISCONNECT BOX