draft risk assessment for uk manufactured factor xi and potential vcjd exposure steven anderson,...
TRANSCRIPT
![Page 1: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/1.jpg)
Draft Risk Assessment for UK manufactured Factor XI
and Potential vCJD Exposure
Steven Anderson, PhD, MPP
Office of Biostatistics & EpidemiologyCenter for Biologics Evaluation and Research
U.S. Food and Drug Administration
![Page 2: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/2.jpg)
Elements of Risk AssessmentNAS (1983)
I. Hazard identification• Establishes causality between hazard and adverse
effects
II. Dose response (Hazard characterization)• Probability of response – infection or illness
III. Exposure assessment• Frequency and Quantity of exposure
IV. Risk characterization• Probability of occurrence, severity of adverse effects • Uncertainty • Sensitivity analysis
![Page 3: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/3.jpg)
Quantitative Risk Assessment
l Commonly used when uncertainty about a risk is high !
l Uncertainty is pervasive in risk assessment
l FDA plasma derivative risk assessments include:n Model - FDA model is a computer modeln Document - organized according to NAS framework
![Page 4: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/4.jpg)
Quantitative Risk Assessment
– “Link” relevant data together in a meaningful way
– Estimate potential exposure / risk
– Framework to identify critical elements where research will improve model
– Understand key elements that “drive” risk
– Risk assessment is an iterative process – updated as new data / information emerge
![Page 5: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/5.jpg)
Draft Risk Assessment for U.K. Factor XI and
vCJD
![Page 6: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/6.jpg)
Risk Assessment Question
l Given the recent probable transmission of vCJD via transfusion of non-leukocyte reduced RBC concentrates, what is the risk to US recipients that received human plasma derived Factor XI product from 1989 to 1997 manufactured from UK plasma?
![Page 7: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/7.jpg)
Factor XI background
l Factor XI –clotting factor present in low concentrations in plasma
l FXI deficiency – rare
l Bleeding is less frequent that with Hemophilias A and B – does not involve joints or muscle
l Bleeding associated with surgery
![Page 8: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/8.jpg)
Elements of Risk AssessmentNAS (1983)
I. Hazard identification
II. Dose response (Hazard characterization)
III. Exposure assessment
IV. Risk characterization
![Page 9: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/9.jpg)
I. Hazard Identification
l In-depth review of available data and information
l Establishes causality between TSE agent in blood and infection and/or illness
![Page 10: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/10.jpg)
I. Hazard Identification (cont’d)
l Two recent cases of probable transfusion-transmitted vCJD in United Kingdom
l Raise possibility of transmission of vCJD via plasma derived products
l To date vCJD transmission via plasma derivatives has not been observed
![Page 11: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/11.jpg)
I. Hazard Identification (cont’d)
l Factor XI Risk Assessment
l vCJD transmission via Factor XI is a potential hazard
l UK manufactured Factor XI was used in United States under investigational new drug (IND) status from 1989 to 1997
![Page 12: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/12.jpg)
Elements of Risk AssessmentNAS (1983)
I. Hazard identification
II. Dose response (Hazard characterization)
III. Exposure assessment
IV. Risk characterization
![Page 13: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/13.jpg)
II. Dose response(or Hazard characterization)
l Relates amount of agent in dose to probability of infection or illness
Prob
abi l
ty o
f i n
fect
i on
50%
100%
1 2Quantity of agent
![Page 14: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/14.jpg)
II. Dose response(or Hazard characterization)
l Challenges for determining dose response for TSE diseasesn Human data absent
– Quantity agent in human blood? Plasma?– Variation?– Present throughout incubation period?– Genetics & susceptibility of humans
– Threshold? Or not?
– Accumulation of agent in humans?
n Animal data available– Does data approximate human situation well?
![Page 15: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/15.jpg)
II. Dose response(or Hazard characterization)
Commonly used dose terminology and metric in TSEs
One ID50 = dose necessary to initiate infection in 50% of the exposed population
– vCJD inferences based on animal TSE data !– Extrapolation of animal data to human outcomes = highly uncertain– Assumption in risk assessment: animal data approximates infection / illness in humans– We don’t know if assumption is accurate or not !
l Exposure may not lead to infection
l Infection may not lead to illness
![Page 16: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/16.jpg)
II. Dose response(or Hazard characterization)
l Dose-response (D-R) provides link to estimating risk based on exposure
l D-R is lacking – or highly uncertain for TSEs
l Therefore – predicting probability of vCJD is extremely uncertain !
Pro
babi
lity
of
infe
ctio
n
50%
100%
1 2Quantity of agent
![Page 17: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/17.jpg)
Elements of Risk AssessmentNAS (1983)
I. Hazard identification
II. Dose response (Hazard characterization)
III. Exposure assessment
IV. Risk characterization
![Page 18: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/18.jpg)
III. Exposure Assessment
l Frequency or probability of exposure to vCJD agent
l Quantity of vCJD agent to which an individual is exposed
![Page 19: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/19.jpg)
III. Exposure Assessment Factor XI Risk Assessment
Key aspects of exposure assessment:
l (A) vCJD ID50 in plasma pooln Probability of agent in pool and n Quantity (dose) TSE agent in starting pool
l (B) Reduction during manufacture
l (C) Dose per surgery or treatment(s)n Quantity of vCJD agent in final productn Amount of product used by patients
![Page 20: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/20.jpg)
Percentage pool used in production Log10 reduction ID50 during processing
ivID50 per unit FXIivID50 per vialScenarios: include a pre- and post-surgery dose 20 – 50 u/kg
Module AvCJD ID50
plasma pool
Module BReduction in manufacture
Module CDose per surgery
Input Module Output
ID50 in FXI post-processingYield FXI plasma poolTotal ID50 per vial
Exposure estimate vCJD iv ID50
Exposure estimates 3 scenarios
•Total i.c. ID50 per vCJD donationTotal i.v. ID50 per plasma pool of 20,000 donations
Probability vCJD in UK Number vCJD donations per pool ID50 per ml plasma
Factor XI Risk AssessmentExposure Assessment Overview
![Page 21: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/21.jpg)
III. Exposure Assessment : (A) vCJD ID50 in plasma pool
l Probability vCJD ID50 in pool or product – directly related to prevalence of vCJD in population
l Disparity in scientific literature between mathematical models and surveillance data
l Mathematical models:l (1) Ghani et al 2000
l vCJD estimate 70 to 236,000 clinical casesl Or 1 in 840,000 to 1 in 500
(2) Ghani et al 2003 l vCJD estimate median 100 cases (10 – 2,600 - 95% CI)l Median 1 in 500,000
l (3) Llewyn et al 2004l vCJD infection 1 in 15,000 to 1 in 30,000
![Page 22: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/22.jpg)
III. Exposure Assessment : (A) vCJD ID50 in plasma pool
l Surveillance data:l Hilton et al 2004
Surveillance study tonsil/appendices (Hilton, et al. 2004) – 3 prion positive samples in 12,674 samples tested
237 positives per million individuals Model assumes mean vCJD prevalence
of 1 in 4,224
l FDA rationale for use of surveillance datan Represent “real” data of possible incubating casesn Conservative – but uncertain estimate of prevalencen Model data – mostly estimate clinical vCJD casesn Non-clinical or asymptomatic infections have potential for
transfusion transmission
![Page 23: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/23.jpg)
III. Exposure Assessment : (A) vCJD ID50 in plasma pool
l Estimate prevalence vCJD in donor population to estimate probability of vCJD ID50 in plasma pool
l United Kingdom: (1) Mathematical modeling results (2) Surveillance study – tonsil & appendices
l United States:l Possible sources vCJD dietary exposure to BSE agent:l (1) History extended travel/residence in UK or Europe
(2) Domestic dietary exposure of US residents (3) Others – dietary supplements, etc.
![Page 24: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/24.jpg)
III. Exposure Assessment: (A) vCJD ID50 in plasma pool
Factor XI Risk Assessment
Probability of exposure - Prevalence vCJD determines number vCJD donations per pool!
(1) Prevalence of vCJD in UK population Surveillance study tonsil/appendices (Hilton, et al. 2004) – 3 prion positive
samples in 12,674 samples tested
Mean of 1 positive in 4,225 individuals or 237 positives per million individuals
(2) Number vCJD donations per pool Average of 4.7 donations per pool of 20,000 donations
![Page 25: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/25.jpg)
U.K. vCJD prevalence & Number vCJD donations per plasma pool
Factor XI Risk Assessment
Prevalence UK PopulationvCJD cases per million
Mean 95% confidence interval
237 49 to 692
Triangular distributionParameters
Mean Range
UK Plasma poolNumber vCJD donations
per 20,000 donations
~ 5
(Most likely = 2)
0 to 14
Prevalence x 1 million20,000
1
50
![Page 26: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/26.jpg)
III. Exposure Assessment: (A) vCJD ID50 in plasma pool
l What is the Quantity TSE agent in starting plasma pool?
l Amount infectivity per donation and pooln Estimates of infectivity in human blood derived from
animal data
l Number TSE donations per pool(s)n Higher prevalence/incidence of TSE disease – greater
chance of multiple donations containing TSE agent in pool
![Page 27: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/27.jpg)
III. Exposure Assessment: (A) vCJD ID50 in plasma pool
Factor XI Risk Assessment
Quantity of vCJD ID50 present - per ml plasma
Intercerebral (i.c.) ID50 per ml blood Minimum 0.1 Most likely 10 Maximum 1,000
Model assumes 58% associated with plasma (Gregori, et al. 2004)
Assume adjustment 5 to 10 fold reduced efficiency of intravenous vs. intracerebral route of exposure
![Page 28: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/28.jpg)
III. Exposure assessment: Module B Reduction during manufacture
Parameter Minimum Most Likely Maximum
Log10 reductions vCJD agent 0 2.0 4.0
Factor XI Risk AssessmentLog10 reduction ID50 during processing
Reduction based on processing stepsVariability in processing and level(s) of reduction achieved
Assumption used in model:
![Page 29: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/29.jpg)
III. Exposure Assessment: Module C: Dose per surgery or treatment(s)
l Package size (vial, vial size, # units, etc.)
l TSE ID50 per package
l One-time or chronic /multiple use of product
l Utilization may vary by severity of disease
l Estimate of utilization - precise as possible
![Page 30: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/30.jpg)
III. Exposure assessment: Module C: Dose per surgery or treatment(s)
Factor XI Risk Assessment
Utilization of UK-manufactured FXI in USA by patients
Scientific literature indicates common dosing with Factor XI Surgery-related dose(s) of 20 – 50 u/kg
Three possible dose scenarios range in the following:
Scenario 1: 3,000 u ( 1 treatment 60kg x 50 u ) Scenario 2: 9,000 u ( 3 treatments 60kg x 50 u ) Scenario 3: 15,000 u ( >3 treatments )
![Page 31: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/31.jpg)
Elements of Risk AssessmentNAS (1983)
I. Hazard identification
II. Dose response (Hazard characterization)
III. Exposure assessment
IV. Risk characterization
![Page 32: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/32.jpg)
IV. Risk Characterization
l Integration of exposure and dose response information to estimate risk
l TSE dose response information lacking – Not possible to precisely estimate risk
l TSE risk assessments – characterize exposurel Really are TSE exposure assessments
l Can draw limited qualitative conclusions about risk – Low level of exposure – low level of risk, etc.
![Page 33: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/33.jpg)
Key Parameters in TSE Plasma Model
Parameter Minimum Most Likely Maximum
# vCJD donations per pool 20,000 donations
0 2(mean ~5)
14
Pool Size 20,000 donors
Recovered plasma 200 ml
vCJD Blood ic ID50 / ml 0.1 10 1,000
% infectivity in plasma 58 %
Adjustment efficiency ic route vs intravenous route administration
5 10
Log10 reduction vCJD agent
0 2.0 4.0
Total yield FXI from pool (units / L plasma)
150 units 180 units
FXI units per vial 1,000 units
![Page 34: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/34.jpg)
Results Factor XI Risk Assessment Model: Exposure to vCJD iv ID50 via Factor XI
Scenario Quantity Factor
XI Utilized
Mean vCJD
iv ID50 5th
percentile
95th
percentile
A single unit FXI 1 u 2 x 10-5 6.8 x 10-7 7.0 x 10-5
One vial FXI 1,000 u 2 x 10-2 6.8 x 10-4 7.0 x 10-2 Scenario 1:
1 Treatment 60 Kg person
3,000 u 6 x 10-2 2.1 x 10-3 0.21
Scenario 2: 3 Treatments 60 Kg person 9,000 u 0.17 6.2 x 10-3 0.6
Scenario 3: >3 Treatments
per person 15,000 u 0.28 1.0 x 10-2 1.0
![Page 35: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/35.jpg)
IV. Risk Characterization (cont’d)
l Model:l Reflects mathematical approximation of realityl Predicted risk is product of UNCERTAINTY in data and
assumptions
l Probabilistic model– uses statistical distributions
l Monte Carlo method – randomly chooses values from distributions used in model and estimates risk
l Repeats process thousands of iterations– Software - @Risk, Crystal Ball, Analytica, etc.
![Page 36: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/36.jpg)
IV. Risk Characterization (cont’d)
l Uncertainty:l Arises from lack of information
l Express uncertain outcomes from model using l measures central tendency – mean, median, etc.
l Express uncertainty with confidence intervals– 95% CI , 5th and 95th percentiles, etc.
![Page 37: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/37.jpg)
IV. Risk Characterization (cont’d)
l Sensitivity Analysis :l Determines what factors in model have greatest
influence on risk estimate
l Done by varying parameters in model by percentages (25%, 50%, etc.) and observing impact on risk estimates
l Can be done for multiple outcomes
l Identifies factors in model where additional information may improve risk estimate
![Page 38: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/38.jpg)
IV. Risk Characterization (cont’d) Sensitivity Analysis
l Factor XI risk assessment
l Two major factors influence risk:
l (1) Number of vCJD donations per plasma pool– Risk reduction measures – donor deferrals
l (2) Log10 reduction of vCJD agent during manufacture of product
– Risk reduction measures – manufacturing processes that reduce vCJD agent in product
– Additional validated processing steps may further reduce risk
![Page 39: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/39.jpg)
IV. Risk Characterization (cont’d)
l Model Validation : l Emerging situations – epidemiological data on outcomes may not be
available– Uncertainty about risk high – risk assessment used to estimate risk
l Lack of Epidemiological data - formal model validation may not be possible
l “Anchor” components of model with data– Known levels of TSE clearance– Utilization, etc.
l Empirical data / Epidemiological data preferred over model or risk assessment estimates !
![Page 40: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/40.jpg)
Objectives of Risk Assessment
• Address a specific policy question for decision making• Is there a risk? • Magnitude of risk?• Risk Reduction measures?
• Identify data gaps and research priorities
![Page 41: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/41.jpg)
Data Gaps
More data are needed on:• Prevalence of vCJD in UK, USA, etc.
• Amount vCJD agent present in human blood & plasma
• Progression of vCJD and variability of levels of infectivity in blood & plasma
• Variability in reduction of vCJD agent during various processing steps
• Many other parameters
![Page 42: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/42.jpg)
Conclusions: Factor XI Risk Assessment
l Potential exposure to vCJD agent in Factor XI manufactured in the U.K. and used under IND in the U.S. from 1989 to 1997 was estimated in this probabilistic risk assessment.
l It is possible that FXI product manufactured from U.K. plasma may have been manufactured from plasma pools that contained a plasma donation(s) from an individual that was incubating vCJD.
l To date, no recipients of plasma derivatives in the U.K. or elsewhere have been diagnosed with vCJD.
l Given the potentially prolonged incubation times for human TSEs, it is still theoretically possible that such transmissions occurred are yet to be identified.
![Page 43: Draft Risk Assessment for UK manufactured Factor XI and Potential vCJD Exposure Steven Anderson, PhD, MPP Office of Biostatistics & Epidemiology Center](https://reader035.vdocument.in/reader035/viewer/2022070413/5697bfe31a28abf838cb53cd/html5/thumbnails/43.jpg)
Acknowledgements
• Hong Yang, OBE• Dorothy Scott, OBRR• Mark Weinstein, OBRR• David M. Asher, OBRR• Rolf Taffs, OBRR• Pedro Piccardo, OBRR• Other OBRR Staff