dr.fixit flexi pu 270(i)
TRANSCRIPT
Dr.Fixit Flexi PU 270(I)
Solvent Based Polyurethane Waterproof Membrane
S-PI-001 Rev.EN05 02 October 2020 Page 1/5
Te
ch
nic
al
Da
ta S
he
et
: D
r.Fix
it
Fle
xi P
U 2
70
(I)
Description Dr. Fixit Flexi PU 270(I) is Polyurethane Waterproof membrane based on pure elastomeric hydrophobic polyurethane resins It’s liquid-applied, highly permanent elastic, cold applied, cold
curing, and low VOCs properties.
The Dr. Fixit Flexi PU 270(I) is good result in excellent mechanical, chemical, thermal and
natural element resistance properties. It’s reacts with ground and air moisture to cure. Areas of Application
Concrete roof, asbestos roof and metal sheet roof Retaining wall, foundations, Underground tunnel
Rate of uses * Theoretical consumption without allowance for loss.
Rate of uses
Kg/m2 M2/pails (25 kg)
Standard At Least At Most
1 Coat 0.68 0.60 0.75 36
2 Coats 0.68 0.60 0.75 36
Total 2 Coats 1.35 1.20 1.50 18
Thickness
Thickness (micron)
Standard At Least At Most
1 Coat 300 250 350
2 Coats 300 250 350
Total 2 Coats 600 500 700
Method of Application
1. Surface Preparation 1.1 Old & Fresh Concrete Surface
Allow fresh concrete to cure 28 days. Always concrete surface must clean, strong, free of all loose dirty materials, and dust
free, oil stain, wax, liquid coating/paint, concrete curing agent, grease or other stains that would affect waterproof coating adhesion.
Always concrete surface where there laitance, algae, mound, remove them with grinding machine and clean surface afterwards.
Usually Prepare cement surface or mineral mix cement surface by cleaning by using
grinding machine or chipping machine to remove all defect surfaces such as peel off surface, weak concrete, cavities, etc. Do not use water to clean surface to prevent
accumulation of moisture. Use grinding machine or chipping machine to smoothen surface and remove all loose dirty materials, sweep off or use blower to blow off dirt or vacuum cleaner to suck in dirt.
Dr.Fixit Flexi PU 270(I)
Solvent Based Polyurethane Waterproof Membrane
S-PI-001 Rev.EN05 02 October 2020 Page 2/5
Te
ch
nic
al
Da
ta S
he
et
: D
r.Fix
it
Fle
xi P
U 2
70
(I)
Tech
nic
al D
ata
Sheet
Dr.
Fix
it
Fle
xi
PU
27
0(I
) Tech
nic
al D
ata
Sheet
Surface Levelling Always surface must be smooth, for laitance remove laitance surface by saw
concrete or scrubbing down with wire brush.
Adjust slope 1:100 on roof terrace application to allow water to drain.
All surface area must be smooth and any defects concrete surface can be apply by
use structure repair cementitious mortar Dr.Fixit UniRepair FC to fill in damage
area, afterwards allow repair area to cure for 7 days prior to other work.
Repair Cracks & Plug Holes
For concrete surface with, weak concrete, peel off surface, hollow sound check
from knock at concrete condition remove by grinding machine or chipping machine
till reaching strong concrete.
For concrete surface with pinhole or honeycomb can be apply by using structural
repair cementitious mortar Dr.Fixit UniRepair FC to fill in defects area,
afterwards allow repair area to cure for 7 days prior to other work.
For concrete surface with >3mm crack, groove U shape on crack area to big enough
for apply Dr. Fixit MS 25 Sealant to seal crack and allow to cure a day prior to
working on area.
For concrete surface with 0.5 – 1 mm. (hairline crack) apply Dr.Fixit Flexi PU 270
(I) over hairline crack
Fillet on joints wall and floor
For concrete wall and floor should be made fillet/chamfer with Dr. Fixit MS 25
Sealant. Allow sealant to cure for a day prior to other work.
Any corners or angles should be cut.
Floor drain area or drainage cell should be seal joints in between drain and surface with Dr. Fixit MS 25 Sealant.
2. Priming
Concrete surface moisture level must not exceed 5% if exceeded recommend use
Dr.Fixit Denzi Block (Depending on surface conditions) Porous surface must be
apply Dr.Fixit Denzi Block 2 coats, leave coat to dry completely 1-2 hours before
apply second coat and allow the coating to cure for 24 hours.
3. Mixing
Dr.Fixit Fixit Flexi PU 270(I) is premix product; stir content till a homogenous paste is
form prior to applying. Do not add more water when mixing.
Leave Dr.Fixit Flexi PU 270(I) to reducing air bubbles about 1 minute.
4. Application
Pour the Dr.Fixit Flexi PU 270(I) onto the primed surface and lay it out by roller, towel
or brush, until all surfaces is covered. (Recommend at 500-700 micron dry film thickness).
Dr.Fixit Flexi PU 270(I)
Solvent Based Polyurethane Waterproof Membrane
S-PI-001 Rev.EN05 02 October 2020 Page 3/5
Te
ch
nic
al
Da
ta S
he
et
: D
r.Fix
it
Fle
xi P
U 2
70
(I)
Leave 1st coat to dry with 12-18 hours (depends on temperature and humidity surface) but should not later than 48 hours before apply another layer of the Dr.Fixit Flexi PU
270(I).
Applying 2nd coat of Dr.Fixit Flexi PU 270 (I) Strengthen Dr.Fixit Flexi PU 270 (I) with Dr.Fixit Roofkote Fibrenet or Dr.Fixit
Roofkote Polymat system while applying 2nd coat and apply 3rd coat of the Dr.Fixit Flexi
PU 270(I) before topcoat with polyurethane waterproof.
For demanding applications, after applying 2nd coat finished can apply Silica Quartz onto
surface for anti-skid flooring, leave coat to dry about 12 – 18 hours (depends on
temperature and humidity surface) before topcoat with polyurethane waterproof.
5. Finishing If a color stable and chalking-free surface is desired, apply top coat of the Dr. Fixit
Hydrolastic PU/ Dr.Fixit Hydrolastic PU Cool/Dr.Fixit Newcoat PU Cool/Dr.Fixit PU Roofkote over the Dr.Fixit Flexi PU 270(I) for two coats at 300 to 350 micron approximately dry film thickness.
Allow 1st coat to dry 1 to 2 hours prior to applying 2nd coat perpendicularly, do not add more water in mixture when applying
When applying floor to wall joint apply top coat at least 30 cm height above floor level Allow top coat to cure 7 days after applying application steps above prior to opening to
traffic
6. Cleaning Clean all tool and equipment with water immediately after use.
Limitations & Precautions
Dr.Fixit Flexi PU 270(I) working temperature 10 to 35◦C. The temperature and
humidity affects the completely dryness. Dr. Fixit Flexi PU 270 (I) should be have topcoat coating over it. Do not leave it bare to
the sun at all times. Dr.Fixit Flexi PU 270(I) should be leave to completely dryness and recommend at 500-
700 micron dry film thickness.
Do not apply area regularly immerse in water such as water tank, swimming pool Do not mix water into Dr.Fixit Flexi PU 270(I)
Dr.Fixit Flexi PU 270(I)
Solvent Based Polyurethane Waterproof Membrane
S-PI-001 Rev.EN05 02 October 2020 Page 4/5
Te
ch
nic
al
Da
ta S
he
et
: D
r.Fix
it
Fle
xi P
U 2
70
(I)
Tech
nic
al D
ata
Sheet
Technical Datasheet
Properties Standard/Test Method Results
1.Specific gravity DIN 53217 1.320 ~ 1.420
2.Solid Content (%) - 90%
3.Elongation at Break ASTM D-412/ DIN 52455 400%
4.Tensile Strength (with accelerator) ASTM D 412 / DIN 52455 4 ~ 6 MPa
5.Tensile Strength (without accelerator)
ASTM D 412 / DIN 52455 2 ~ 4 MPa
6.Water Vapour Permeability ISO 9932:91 > 14 gr/m2/day
7.Resistance to Water Pressure (1m water column, 24h)
DIN EN 1928 No Leak μ = 2.500
8.Adhesion to concrete (concrete surface failure)
ASTM D 903 >2,0 N/mm2
9.Hardness (Shore A Scale) ASTM D 2240 (15”) 75
10.Thermal Resistance (80ºC for 100
days)
EOTA TR-011 Passed
11.Service Temperature - –40ºC to +80ºC
12.Tack Free Time - 5 to 6 hrs.
13.Light Pedestrian Traffic Time - 24 hours
14.Final Curing time Conditions: 20ºC, 50% RH
- 7 days
15.Fire resistance - Euroclass F
16.Resistant to plant roots - Resistant
17.Crack Bridging - Up to 2 mm if coating thickness is > 2 mm
Dr.Fixit Flexi PU 270(I)
Solvent Based Polyurethane Waterproof Membrane
S-PI-001 Rev.EN05 02 October 2020 Page 5/5
Te
ch
nic
al
Da
ta S
he
et
: D
r.Fix
it
Fle
xi P
U 2
70
(I)
Dr.
Fix
it
Fle
xi
PU
27
0(I
) Tech
nic
al D
ata
Sheet
Dr.
Fix
it
Fle
xi
PU
27
0(I
) Tech
nic
al D
ata
Sheet
Dr.
Fix
it
Fle
xi
PU
27
0(I
) Tech
nic
al D
ata
Sheet
Packaging: Dr.Fixit Flexi PU 270(I) is supplied in 25 kg, Barrels. The Dr.Fixit Flexi PU 270(I) is supplied in white.
Storage: Pails should be stored in dry and cool rooms for up to 9 months. Protect the material
against moisture and direct sunlight. Storage temperature: 5º-30ºC. Products should remain in their original, unopened containers, bearing the manufacturers
name, product designation, batch number and application precaution labels.
Health & Safety Precautions During application wear protective clothing, gloves and eye goggles during application.
Avoid product to contact eyes and skin.
Skin Contact: Wash immediately with plenty of clean water.
Eye contact: In the event of eye contact splash plenty of clean water immediately and
seek medical advice.
Dr.Fixit Flexi PU 270(I) contains isocyanates.
Disclaimer The product information and the recommendations relating to the application and end-use of Dr.Fixit products, are based on Dr.Fixit’s current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Dr.Fixit’s recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product’s suitability for the intended application and purpose. Dr.Fixit reserves the right to change the properties of its products without notice, so the company does not assume liability of any legal from this product information.
Bamco Supply & Services Limited(A group company of Pidilite Industries Ltd.) 699 ModernformTower 15,17 FL.,Srinakarin Rd., Pattanakarn, Suan Luang, Bangkok 10250, THAILAND. T. +662 722-8535 F. +662 722-8381 Website: www.dr-fixit.co.th
E-mail: [email protected]
Helpline Call +662 722 8535 #101