DRILLERS INTERCOM SYSTEM

DATASHEET

 

 

 

 

 

JUNHO 2013

Features■ Hands-free Operation

■ 16 Subscriber selectors fitted as standard

■ Star wired system architecture

■ Single pair field cables no multi-coreor special cable

■ Safe, simple communication

■ Simple, easy maintenance

■ Elimination of common mode failure

DX3+1 Drillers Talkback Intercom System

Drillers TalkbackIntercom System

The entire system is designed to facilitate controlfrom the driller’s position, to this end all stationsare hands-free including the Driller’s station.

The Driller position comprises of the followingATEX certified DX3+ apparatus:

■ 200 mm/600 mm long reach gooseneckmounted intrinsically safe EExi microphonefitted to DX3MC16 control membrane panel

■ Thigh/Knee/Foot EEx Switch to facilitatecommunication control type KNS01.

■ Driller “receive speech“ EEx Loudspeaker

DescriptionThe BARTEC VODEC DX3+1 Driller’s Intercomsystem has been speci f ical ly designed inconjunction with drilling operations to providereliable, simple two way voice communicationson board a drilling rig.

The system is primarily designed to enhancehealth and safety on board the rig.

It is developed to the same high standards ofsecurity as the BARTEC VODEC Public Addressand General Alarm (PAGA) System which is aprime life safety package.

The DX3+1 system comprises of a central panel,(which carries switching and amplification)Dri l ler ’s cabin master control , subscriberstation(s) and paging loudspeaker(s).

Diagram of Hands-free Drillers Talkback Intercom System

Hazardous Area subscribers Safe Area (e.g. Switch Room) or Ex Area

1 Pair Cable

Secure ACSupply Input 110 up to 254 V 50/60 Hz

I.S. Earth

Hazardous Area

Low impedanceEEx Drillers TalkbackLoudspeaker Horn

Drillers Thigh/KneeSwitch TalkbackControl KNS01

EEx DrillerSelection SwitchDX3MC16Master Control Unit

Driller’s Cabin

Drill Floor PagingLoudspeaker Horn(s)

DX3+1 Central Switch

EEx Intercom/Paging Horn

SubscriberStation #2

EEx Intercom/Paging Horn

SubscriberStation #N

1 Pair Cable

EEx Intercom/Paging Horn

SubscriberStation #1

~

1 Pair Cable

1 Pair Cable

1 Pair Cable

1 Pair Cable

1 Pair Cable

1 Pair Cable

1 Pair Cable

Subscriber Stations

Subscriber positions comprise of glass reinforcedmicrophone and loudspeaker unit with up tosixteen stations possible to connect to a singleDX3+1 switch.

■ VAP01-GO can be fitted where an extendedreach microphone is required.

■ Simple subscriber unit with microphone andsingle button.

■ For certain locations, e.g. shale shaker,an acoustic shelter aids intelligiblecommunications.

The DX3+1 Switch can support a Driller’s cabinfitted with dual chairs. In this instance two KNS01knee/thigh control switches and two mastercontrol access panels type DX3MC16 are installedto allow dedicated control to each chair.

DescriptionThe BARTEC VODEC DX3+1 is a driller’s talkbackintercom system designed to enable reliable safetycritical two way communication between a masterDriller’s position and strategic rig locations.

The DX3+1 system is managed and controlledfrom a DX3MC16 control panel which allows thedriller to conveniently establish communicationplans for hands-free operation.

The unit comprises of a robust low profileenclosure which carries a tactile membranekeyboard (which is fitted with large illuminatingsubscriber channel selector keys) and an extended“long reach“ gooseneck mounted noise cancellingmicrophone.

The DX3MC16 is ATEX certified for safe use in aZone 1 IIC potentially explosive atmospheres and

Features■ 16 Subscriber selectors fitted as standard

■ Single pair connectivity

■ Membrane keyboard

■ Simple system expansion

■ Easy installation, rapid commissioning

DX3MC16 Master Control Panel

Drawing

MasterControl Panel

is rated intrinsically safe when used in con-junction with BARTEC VODEC central equipment.

The DX3MC16 is fitted with a BARTEC VODECVAP100a transceiver which provides modularplug in/out interface facilitating rapid service.

Connection between the control unit and the hostDX3+1 central rack is by a single cable pair whichcarries phantom DC power supply, data and statusindication control.

Diagrammshows connection of DX3MC16 mastercontrol unit linked to host equipment

VAP100a

DX3MC16Control Position

Central Rack

MTL7758Barrier

3Data Tx

Data Tx

Screen

Explosion protectionEx protection

II 2G Ex ib IIC T4-40 °C < Ta < +60 °C

Technical DataATEX Certified

Zone IIC T4Hazardous Area 1 Certification

Dimensions250 mm wide350 mm high55 mm deep

Weight1kg

FinishBack enclosure electroplate steel

Power supply5V DC phantom powered

TransceiverVAP100a

5

4

3

1

42