1
Color according to implant 11 13 6 8 9 3 2.5/3.1 Position number Diameter 11 13 6 8 9 15 17 3 2.5/3.1 Guide Drill EV Precision Drill EV B A -Cortical Drill EV Ø2.5/2.7 B -Cortical Drill EV Ø2.5/3.0 A 1 2 1 -Twist Drill EV Ø1.9 2 -Step Drill EV Ø1.9/2.5 V -Twist Drill EV Ø2.5 X -Step Drill EV Ø2.5/2.85 A -Cortical Drill EV Ø3.1/3.3 B -Cortical Drill EV Ø3.1/3.6 A B 1 3 1 -Twist Drill EV Ø1.9 3 -Step Drill EV Ø2.5/3.1 V -Twist Drill EV Ø3.1 X -Step Drill EV Ø3.1/3.45 A -Cortical Drill EV Ø3.7/3.9 B -Cortical Drill EV Ø3.7/4.2 A B 1 3 4 1 -Twist Drill EV Ø1.9 3 -Step Drill EV Ø2.5/3.1 4 -Step Drill EV Ø3.1/3.7 V -Twist Drill EV Ø3.7 X -Step Drill EV Ø3.7/4.05 A -Cortical Drill EV Ø4.3/4.5 B -Cortical Drill EV Ø4.3/4.8 A B 1 3 5 1 -Twist Drill EV Ø1.9 3 -Step Drill EV Ø2.5/3.1 5 -Step Drill EV Ø3.7/4.3 V -Twist Drill EV Ø4.3 X -Step Drill EV Ø4.3/4.65 A B A -Cortical Drill EV Ø4.9/5.1 B -Cortical Drill EV Ø4.9/5.4 1 3 5 6 1 -Twist Drill EV Ø1.9 3 -Step Drill EV Ø2.5/3.1 5 -Step Drill EV Ø3.7/4.3 6 -Step Drill EV Ø4.3/4.9 V -Twist Drill EV Ø4.9 X -Step Drill EV Ø4.9/5.25 Astra Tech Implant System® Dentsply Sirona does not waive any right to its trademarks by not using the symbols ® or ™. 32671 345-USX-1 706 © 20 1 7 Dentsply Sirona. All rights reserved. OsseoSpeed® EV drilling protocol overview A unique drilling protocol has been developed to allow for preferred primary implant stability. The strategy with the drilling protocol is to provide apical bone support to the implant when indicated, but relieve the apex from bone contact when this support is not indicated. Drilling protocol for straight implants Drilling protocol for conical implants Alternative spongious bone preparation V-Twist Drill – extra apical preparation Following opening of the marginal cortical layer with cortical drill A , B or conical drill A / B , the V drill is used to relieve the apical bone support when this support is not indicated. Color: corresponds to implant Note: for conical implants, this color refers to the implant body diameter. X-Step Drill – extra body preparation Following opening of the marginal cortical layer with cortical drill B or conical drill A / B , the X drill, in addition to relieving the apical bone support, is used to widen the body portion of the osteotomy in situations with more dense bone e.g. the lower jaw. Note: for conical implants, this color refers to the implant body diameter. Thin cortical bone (less than 2 mm) Spongious bone Thick cortical bone B A Spongious bone preparation Twist Drill: Used for initial preparation and evaluation of the bone 1 . Step Drill: Used for site preparation, resulting in a stepped osteotomy with apical bone support for the implant. The drills 2 6 provide guidance during the drilling process. 1 2 3 4 5 6 Cortical bone preparation – straight implants Mandatory preparation of the cortical layer to reduce pressure in the bone around the implant neck. Note: There are separate cortical drills specific for the 6 mm implant. A B Cortical bone preparation – conical implants Mandatory preparation of the cortical layer to reduce pressure in the bone around the implant neck. A B Guide Drill EV Precision Drill EV 1 -Twist Drill EV Ø1.9 3 -Step Drill EV Ø2.5/3.1 V -Twist Drill EV Ø3.1 X -Step Drill EV Ø3.1/3.45 V -Twist Drill EV Ø3.7 X -Step Drill EV Ø3.7/4.05 1 -Twist Drill EV Ø1.9 3 -Step Drill EV Ø2.5/3.1 4 -Step Drill EV Ø3.1/3.7 A /B -Conical Drill EV Ø3.7/4.8 A /B -Conical Drill EV Ø3.1/4.2 1 1 3 3 4 Note: for conical implants, color refers to the implant body diameter Drilling protocol overview – Astra Tech Implant System® EV

Upload: lykhuong

Post on 30-Jul-2018

225 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Drilling protocol overview – Astra Tech Implant System … · Color according to implant 11 13 6 8 9 3 2.5/3.1 Position number Diameter 11 13 6 8 9 15 17 3 2.5/3.1 Guide Drill EV

Color according to implant

11 136

89

3 2.5/3.1

Position number

Diameter

11 136

89

1517

3 2.5/3.1

Guide Drill EV Precision Drill EV

B

A -Cortical Drill EV Ø2.5/2.7

B -Cortical Drill EV Ø2.5/3.0

A

1 21 -Twist Drill EV Ø1.9

2 -Step Drill EV Ø1.9/2.5

V -Twist Drill EV Ø2.5

X -Step Drill EV Ø2.5/2.85

A -Cortical Drill EV Ø3.1/3.3

B -Cortical Drill EV Ø3.1/3.6

A

B

1 31 -Twist Drill EV Ø1.9

3 -Step Drill EV Ø2.5/3.1

V -Twist Drill EV Ø3.1

X -Step Drill EV Ø3.1/3.45

A -Cortical Drill EV Ø3.7/3.9

B -Cortical Drill EV Ø3.7/4.2

A

B

1 3 41 -Twist Drill EV Ø1.9

3 -Step Drill EV Ø2.5/3.1

4 -Step Drill EV Ø3.1/3.7

V -Twist Drill EV Ø3.7

X -Step Drill EV Ø3.7/4.05

A -Cortical Drill EV Ø4.3/4.5

B -Cortical Drill EV Ø4.3/4.8

A

B

1 3 51 -Twist Drill EV Ø1.9

3 -Step Drill EV Ø2.5/3.1

5 -Step Drill EV Ø3.7/4.3

V -Twist Drill EV Ø4.3

X -Step Drill EV Ø4.3/4.65

A

BA -Cortical Drill EV Ø4.9/5.1

B -Cortical Drill EV Ø4.9/5.4

1 3 5 61 -Twist Drill EV Ø1.9

3 -Step Drill EV Ø2.5/3.1

5 -Step Drill EV Ø3.7/4.3

6 -Step Drill EV Ø4.3/4.9

V -Twist Drill EV Ø4.9

X -Step Drill EV Ø4.9/5.25

Astra Tech Implant System®

Den

tsp

ly S

iro

na d

oes

no

t w

aive

any

rig

ht t

o it

s tr

adem

arks

by

not

usin

g t

he s

ymb

ols

® o

r ™

. 32

671

 34

5-U

SX-1

 70

6 ©

20

 1 7 D

ents

ply

Sir

ona

. All

rig

hts

rese

rved

.

OsseoSpeed® EV drilling protocol overviewA unique drilling protocol has been developed to allow for preferred primary implant stability. The strategy with the drilling protocol is to provide apical bone support to the implant when indicated, but relieve the apex from bone contact when this support is not indicated.

Drilling protocol for straight implants

Drilling protocol for conical implants

Alternative spongious bone preparation

V-Twist Drill – extra apical preparation Following opening of the marginal cortical layer with cortical drill A , B or conical drill A/B , the V drill is used to relieve the apical bone support when this support is not indicated.

Color: corresponds to implant Note: for conical implants, this color refers to the implant body diameter.

X-Step Drill – extra body preparation Following opening of the marginal cortical layer with cortical drill B or conical drill A/B , the X drill, in addition to relieving the apical bone support, is used to widen the body portion of the osteotomy in situations with more dense bone e.g. the lower jaw.

Note: for conical implants, this color refers to the implant body diameter.

Thin cortical bone (less than 2 mm)

Spongious bone

Thick cortical bone

B

A

Spongious bone preparationTwist Drill: Used for initial preparation and evaluation of the bone 1 .

Step Drill: Used for site preparation, resulting in a stepped osteotomy with apical bone support for the implant. The drills 2 – 6 provide guidance during the drilling process.

1 2 3 4 5 6

Cortical bone preparation – straight implantsMandatory preparation of the cortical layer to reduce pressure in the bone around the implant neck.

Note: There are separate cortical drills specific for the 6 mm implant.

A B

Cortical bone preparation – conical implantsMandatory preparation of the cortical layer to reduce pressure in the bone around the implant neck.

A

B

Guide Drill EV Precision Drill EV

1 -Twist Drill EV Ø1.9

3 -Step Drill EV Ø2.5/3.1

V -Twist Drill EV Ø3.1

X -Step Drill EV Ø3.1/3.45

V -Twist Drill EV Ø3.7

X -Step Drill EV Ø3.7/4.051 -Twist Drill EV Ø1.9

3 -Step Drill EV Ø2.5/3.1

4 -Step Drill EV Ø3.1/3.7

A/B -Conical Drill EV Ø3.7/4.8

A/B -Conical Drill EV Ø3.1/4.2

1

1

3

3 4Note: for conical implants, color refers to the implant body diameter

Drilling protocol overview – Astra Tech Implant System® EV