Dryvit’s HDCITM ProgramHigh Durability Continuous Insulation
![Page 2: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy](https://reader035.vdocument.in/reader035/viewer/2022071511/612fd9d21ecc51586943b774/html5/thumbnails/2.jpg)
Overview
1. Over 30 years in Canada2. Dryvit is sustainable3. Dryvit’s HDCITM Program
High Durability Continuous Insulation
4. Durability proven with CCMC/ULC-S7165. Also fire resistance – testing & listing at ITS6. Most thermally efficient to meet energy code 7. Summary
� In your next specification, here’s what to include…� Good performance hinges on…
Chateau Lake Louise
![Page 3: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy](https://reader035.vdocument.in/reader035/viewer/2022071511/612fd9d21ecc51586943b774/html5/thumbnails/3.jpg)
Dryvit is Sustainable…Embodied Energy
National Institute of Standards & Technology – BEES v4.0
Gre
enes
t
![Page 4: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy](https://reader035.vdocument.in/reader035/viewer/2022071511/612fd9d21ecc51586943b774/html5/thumbnails/4.jpg)
Dryvit is Sustainable…CO2 Emissions
National Institute of Standards & Technology – BEES v4.0
Gre
enes
t
![Page 5: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy](https://reader035.vdocument.in/reader035/viewer/2022071511/612fd9d21ecc51586943b774/html5/thumbnails/5.jpg)
Dryvit’s HDCITM Program…High Durability Continuous Insulation
� 20 Year warranty including substrate moisture protection
� Panzer® 20 & Corner� Industry 1st: impact
resistance warranty� Can be specified for
all Outsulation®
� Outsulation Plus� Outsulation MD� Outsulation PD
![Page 6: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy](https://reader035.vdocument.in/reader035/viewer/2022071511/612fd9d21ecc51586943b774/html5/thumbnails/6.jpg)
Dryvit is…Impact Resistant
4.3 6.0 12.0 15.0+4.3 20.5+4.3(ounces/yd 2)
Inch-pounds
Panzer®
![Page 7: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy](https://reader035.vdocument.in/reader035/viewer/2022071511/612fd9d21ecc51586943b774/html5/thumbnails/7.jpg)
Impact Resistance Guide
MESH TYPE MESH WEIGHT RECOMMENDED LOCATIONS
Standard Mesh 4.3 oz/yd 2 Walls in general service (not readily accessible to pedestrians & maintenance)
Standard Plus 6.0 oz/yd 2 Walls in general service and areas with infrequent access to maintenance
Intermediate 12.0 oz/yd 2 Balcony wall areas, or walls with medium maintenance access
Panzer 15 + Standard
Mesh
15.0 oz/yd 2
+ 4.3 oz/yd2Grade level (within 4 - 8 ft.) with light to medium to heavy pedestrian traffic
Panzer 20 + Standard
Mesh
20.5 oz/yd 2
+ 4.3 oz/yd2Heavy duty reinforcing for walls with medium to heavy pedestrian traffic
Panzer 20 + Standard
MeshHDCITM Panzer Corner & Panzer 20 for
100% of walls.
![Page 8: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy](https://reader035.vdocument.in/reader035/viewer/2022071511/612fd9d21ecc51586943b774/html5/thumbnails/8.jpg)
New Construction
![Page 9: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy](https://reader035.vdocument.in/reader035/viewer/2022071511/612fd9d21ecc51586943b774/html5/thumbnails/9.jpg)
Panelization
![Page 10: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy](https://reader035.vdocument.in/reader035/viewer/2022071511/612fd9d21ecc51586943b774/html5/thumbnails/10.jpg)
Panelization
![Page 11: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy](https://reader035.vdocument.in/reader035/viewer/2022071511/612fd9d21ecc51586943b774/html5/thumbnails/11.jpg)
OVERCladding
![Page 12: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy](https://reader035.vdocument.in/reader035/viewer/2022071511/612fd9d21ecc51586943b774/html5/thumbnails/12.jpg)
RECladding
![Page 13: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy](https://reader035.vdocument.in/reader035/viewer/2022071511/612fd9d21ecc51586943b774/html5/thumbnails/13.jpg)
Dryvit has…CCMC Approval
� Registered since 1998…
� Basis for ULC-S716 Standards
� Adopted by NBC and OBC in 2015
![Page 14: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy](https://reader035.vdocument.in/reader035/viewer/2022071511/612fd9d21ecc51586943b774/html5/thumbnails/14.jpg)
Dryvit has…Fire Testing
![Page 15: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy](https://reader035.vdocument.in/reader035/viewer/2022071511/612fd9d21ecc51586943b774/html5/thumbnails/15.jpg)
Outsulation System(Plus/MD/PD)
Nominal EIFS R-Value Estimated Assembly Value
2” EPS 7.6 9.93” EPS 11.4 13.64” EPS 15.2 17.25” EPS 19.0 20.96” EPS 22.8 24.6
Nominal 3-5/8” Steel Stud Wall – ½” Glass Mat Faced S heathing, Interior ½” Drywall, No Stud Cavity Insulation
Dryvit is…The Most Thermally Efficient
![Page 16: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy](https://reader035.vdocument.in/reader035/viewer/2022071511/612fd9d21ecc51586943b774/html5/thumbnails/16.jpg)
SummaryDryvit Outsulation ®
�Smallest carbon footprint…�+30 years history in Canada �CCMC registered since 1998�Fire testing for noncombustible
construction�Aesthetic versatility unlike no other�HDCITM = 20 Year Warranty +
Impact Resistance
![Page 17: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy](https://reader035.vdocument.in/reader035/viewer/2022071511/612fd9d21ecc51586943b774/html5/thumbnails/17.jpg)
HDCITM in your next specification…
� After specifying Outsulation® Plus, MD, or PD, specify Dryvit’s HDCITM , as follows:� “Dryvit HDCI with Panzer 20 and Panzer Corner
are required for 100% of the wall areas.”� “System manufacturer shall provide a 20 year
warranty, including provisions to repair impact damage through the EIFS lamina, and moisture protection of the substrate.”
EASY!
![Page 18: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy](https://reader035.vdocument.in/reader035/viewer/2022071511/612fd9d21ecc51586943b774/html5/thumbnails/18.jpg)
Good Service Life Hinges on…
� Critical details (design):� Panelization = engineered cladding� High impact resistance = HDCITM
� Stain resistance – detail for rain deflection
� Quality control (construction):� Dryvit requires “Contractor Agreements ”
signatory to Dryvit’s specs & details� Dryvit tech -support during construction
� Maintenance (what & when)� DryvitCARE & maintenance guide