Subject: Oil Sample - Information Lab No:A14H270112, Unit:DT-101, Serial No:0DLS00983 : Hydraulic System
Message: Oil Sample - Information Lab No:A14H270112 Attn: Trakindo Jakarta / Stevanus Parulian (A) More Information ------------------------------------------------------------------ SAMPLE DETAILS 28-Aug-2014 ------------------------------------------------------------------
CURRENT SAMPLE
Customer INDOCEMENT TUNGGAL PRAKARSA PT. Jobsite 109233 - CITEUREUP
Serial No 0DLS00983 Unit No DT-101
Model 775F Make Caterpillar
Oil Type UNKNOWN Oil Grade
Compartment Hydraulic System Compart Serial
Job No Meter 8744
Lab No A14H270112 Sample Date 25-Aug-2014
Eval A Sample Site QUARRY D PT ITP
DETAILS
Lab No Eval Date Sampled Date Received Label Actioned Meter Read Comp. Hours Fluid Hours Fluid Added Fluid Changed Filter Changed
A14H270112 A 25-Aug-2014 26-Aug-2014 10 N 8744 8744 0 0.00 N
A14G240831 B 22-Jul-2014 24-Jul-2014 10 N 8493 8493 1013 0.00 N
A14F250418 B 23-Jun-2014 25-Jun-2014 10 N 8063 8063 630 0.00 N
A13I280106 B 26-Sep-2013 27-Sep-2013 10 N 5996 5996 999 0.00 N
ELEMENT TESTS
Lab No Eval Si Al Cr Fe Pb Cu Sn Ni Na K Mo Zn Mg Ca P B
A14H270112 A 25 3 1 22 0 3 0 1 6 4 0 889 95 3190 818 0
A14G240831 B 25 2 0 17 0 3 0 1 3 0 0 786 91 3033 795 0
A14F250418 B 26 2 0 13 0 3 0 1 3 0 0 750 63 3147 768 0
A13I280106 B 8 1 0 7 0 7 0 1 0 0 0 843 56 2917 829 0
2
LUBRICANT TESTS
Lab No Eval W V100 PQ PC06 PC14 ISO.6 ISO.14
A14H270112 A N 10.32 5 425 48 16 13
A14G240831 B N 10.23 1 3425 53 19 13
A14F250418 B N 10.92 2 3479 49 19 13
A13I280106 B N 8.36 0 6943 202 20 15
COMMENTS
Lab No Eval Comment
A14H270112 A WEAR METALS ARE ACCEPTABLE. ADVISE CHANGING OIL AND FILTER, RESAMPLE AFTER 250 HOURS. BRAND NAME/TYPE OF OIL AND HOURS ON OIL OF SAMPLE ARE NOT STATED ON THE LABEL. SUPPLY COMPLETE DATA TO GET ACCURATE RESULT.
A14G240831 B THE ISO CODE SLIGHTLY ABOVE ACCEPTABLE CLEAN LINES RANGE (NEW CLEAN LINES TARGET = 18/15). ELEVATED SI INDICATED DIRT HAS ENTERED THE SAMPLE. OTHER READINGS ARE ACCEPTABLE. ADVISE TO CHANGE FILTER, CONTINUE TO SAMPLE AT THE NORMAL INTERVAL. GRADE OF OIL NOT STATED ON THE LABEL. SUPPLY COMPLETE DATA TO GET ACCURATE RESULT.
A14F250418 B THE ISO CODE SLIGHTLY ABOVE ACCEPTABLE CLEAN LINES RANGE. OTHER READINGS ARE ACCEPTABLE. TAKE OIL SAMPLES AT 250 HOUR INTERVALS TO MONITOR CONDITION.
A13I280106 B THE ISO CODE SLIGHTLY ABOVE ACCEPTABLE CLEAN LINES RANGE (NEW CLEAN LINES TARGET = 18/15). WEAR METALS ARE ACCEPTABLE. CHANGE FILTER, RESAMPLE AT 1250 HOURS ON OIL. CUT OPEN FILTER AND INSPECT FOR LARGE PARTICLES.