dupont flashing systems installation · pdf filedupont™ flashing systems installation...

104
Installation Instructions for Windows and Doors BEFORE Water-Resistive Barrier (WRB) is Installed DuPont Flashing Systems Installation Guidelines INSTALLATION INSTRUCTIONS FOR WINDOWS AND DOORS BEFORE WATER-RESISTIVE BARRIER (WRB) IS INSTALLED FOR BUILDINGS LESS THAN 5 STORIES REVISION 10/11

Upload: hoangcong

Post on 04-Feb-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Installation Instructions for Window

s and D

oors BEFO

RE W

ater-Resistive Barrier

(WR

B) is Installed

DuPont™ Flashing Systems Installation GuidelinesINSTALLATION INSTRUCTIONS FOR WINDOWS AND DOORS BEFORE WATER-RESISTIVE BARRIER (WRB) IS INSTALLED

FOR BUILDINGS LESS THAN 5 STORIES REVISION 10/11

Page 2: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 2

DuPont™ Flashing Systems Installation Guidelines

Table of ContentsApplicable Products .......................................................................................................... 2Necessary Materials ......................................................................................................... 2Optional Materials ............................................................................................................ 2Recommended Primers .................................................................................................... 3DuPont Recommended Low Expansion Foams ............................................................... 3DuPont Recommended Fasteners ................................................................................... 3General Instructions ......................................................................................................... 3Integral Flanged Window .................................................................................................. 5Integral Flanged Door ..................................................................................................... 10Brick Mold Window ........................................................................................................ 17Brick Mold Door .............................................................................................................. 24Field Applied Flanged Window ....................................................................................... 34Field Applied Flanged Door ............................................................................................. 42Non-Flanged Window ..................................................................................................... 53Non-Flanged Door ........................................................................................................... 60 Alternate Head Detail for Air Barrier Installations ........................................................... 69Integral Flanged Windows in Recessed Openings ......................................................... 78Integral Flanged Windows in Recessed Openings with Open Stud Construction ......... 90Key Installation Requirements for Drainable Window / Door Installation Under the Product and Labor Warranty ........................................................................ 102

Applicable ProductsFlashing Products

PRODUCT DIMENSIONS AREA

DuPont™ FlexWrap™ NF* 6 in x 75 ft 37.50 sq ft 9 in x 75 ft 56.20 sq ft

DuPont™ FlexWrap™* 9 in x 75 ft 56.2 sq ft 9 in x 250 ft 187.5 sq ft

DuPont™ StraightFlash™ 4 in x 150 ft 50 sq ft 9 in x 125 ft 93.75 sq ft

DuPont™ StraightFlash™ VF 6 in x 125 ft 62.5 sq ft

DuPont™ Flashing Tape 4 in x 100 ft 33.33 sq ft 6 in x 100 ft 50.2 sq ft 9 in x 100 ft 75 sq ft

DuPont™ FlexWrap™ RW for Single Stud Application 9 in x 6 in 0.38 sq ftDuPont™ FlexWrap™ RW for Double Stud Application 9 in x 6 in 0.38 sq ft

* These installation instructions are applicable to both DuPont™ FlexWrap™ and FlexWrap™ NF

which can be used interchangeably throughout the installation guide.

Necessary Materials• DuPont™ Flashing• DuPont™ Tyvek® Tape• DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant

Optional Materials• DuPont™ Tyvek® Wrap Caps or other recommended fasteners• Brushes for Surface Preparation• Backer rod• J -roller• Recommended Primers• “L” shaped back dam is a 3/4” corner guard (used on interior gypsum)

Page 3: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 3

DuPont™ Flashing Systems Installation Guidelines

Recommended Primers*MANUFACTURER PRODUCT NAME

3M Hi-Strength 90

Denso Butyl Primer (spray or can)

*Apply per manufacturers’ guidelines. For non-DuPont products, DuPont assumes no liability in use of recommended products; installers need to evaluate suitability of recommended products in their end-use applications.

DuPont Recommended Low Expansion FoamsMANUFACTURER PRODUCT NAME

DuPont DuPont™ Window & Door Foam

DuPont Recommended Fasteners*MANUFACTURER PRODUCT NAME

DuPont DuPont™ Tyvek® Wrap Cap nails

DuPont DuPont™ Tyvek® Wrap Cap screws

DuPont DuPont™ Tyvek® Wrap Cap staples (for Stinger™ or Crossfi re® cap stapler)**

DuPont™ Tyvek® Wrap Cap with alternate screws

1.0 inch minimum crown staples**

* Apply per manufacturers’ guidelines. For non DuPont products, DuPont assumes no liability for use of recommended products; installers need to evaluate suitability of recommended products in their end-use applications.** Except when installing DuPont™ Tyvek® WRBs over foam sheathing and other non-nail-base sheathings.

WarrantyPlease see DuPont Weatherization Products Limited Warranty for buildings less than 5 stories at www.Weatherization.Tyvek.com.

General Instructions For buildings less than 5 stories

For performance requirements exceeding ASTM E1677, 65 mph equivalent structural load and 15 mph equivalent wind-driven rain water infi ltration for buildings less than 5 stories, or for installations that specify a window/door design rating of DP45 or greater, it is recommended to install a high pressure skirt to help prevent water intrusion at the sill or threshold and follow the DuPont™ Flashing Systems Commercial Installation Guidelines.

DuPont™ Flashing Systems products should be installed on clean, dry surfaces that are free of frost. Wipe surfaces to remove moisture, dirt, grease and other debris that could interfere with adhesion.

When cutting the Water-Resistive Barrier (WRB) to prepare the opening, remove an additional 1” strip of the WRB head fl ap to allow more room for the tape adhesive to seal the head fl ashing.

Apply pressure along entire surface of fl ashing for a good bond using a J-roller or fi rm hand pressure.

Remove all wrinkles and bubbles that may allow for water intrusion by smoothing surface and repositioning as necessary.

When fl ashing the sill area for windows and doors, DuPont recommends the use of 6” wide DuPont™ Flexwrap™ NF for 2”x 4” framing and 9” wide DuPont™ Flexwrap™ NF for 2” x 6” framing. As an option, if a rigid back dam is desired, cut the corner back dam the length of the sill and nail into place on the interior edge of the sill prior to installation of DuPont™ Flexwrap™ NF. Then install DuPont™ Flexwrap™ NF over sill and corner guard back dam. If using 6” DuPont™ FlexWrap™ NF with optional rigid back dam, seal ends of corner guard with DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant.

Page 4: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 4

DuPont™ Flashing Systems Installation Guidelines

Door and window rough sill framing must be level or slightly sloped to the exterior to ensure proper drainage to the exterior. This best practice ensures continuous support with positive slope to the exterior.

DuPont™ Residential Sealant and DuPont™ Commercial Sealant should be tooled fl at to allow the natural curing process to create a concave joint.

Please contact your local DuPont™ Tyvek® Specialist for additional information and installation support.

DO NOT STRETCH DuPont™ FlexWrap™ NF when installing along the length of sills or jambs. DuPont™ FlexWrap™ NF is only intended to be extended when covering corners or curved sections.

These installation instructions are applicable to both DuPont™ FlexWrap™ NF and FlexWrap™ which can be used interchangeably throughout the installation guide. However, DuPont™ FlexWrap™ must be secured with recommended fasteners as shown in the illustration at right. DuPont™ Flashing Systems products perform best when installed at temperatures above 25°F (–4°C).

DuPont™ Flashing Systems products should not be installed over cap fasteners.

Priming is generally not required for adhering DuPont™ Flashing Systems products to most common building materials. However, adverse weather conditions or cold temperatures may require use of a primer to promote adhesion. Additionally, concrete, masonry, and glass mat gypsum sheathing require the use of approved primers. For primer recommendations, see page 3.

For additional guidelines, please call 1-800-44-Tyvek (800-448-9835), visit our website at www.Weatherization.Tyvek.com, or consult your local DuPont™ Tyvek® Specialist.

Page 5: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

3

5

21

A

B

E

C

(S)

10“

Sill Width+ 12 inches

6“Minimum

FRONT VIEW CORNER DETAIL

No Gap in Corner

DO NOT STRETCH

WRONG CORRECT

4

Door Jamb

DuPont™FlexWrap™ NF

Sill

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 5

DuPont™ Flashing Systems Installation Guidelines

Integral Flanged Window BEFORE Water-Resistive Barrier (WRB) is InstalledMethod applies to the following products:• DuPont™ StraightFlash™, DuPont™ FlexWrap™ NF, and DuPont™ Flashing Tape

STEP 1 – FOR RECTANGULAR WINDOWS A. Attach apron made of DuPont™ Tyvek® WRB under sill. Apron should extend at least 10” beyond sides of rough opening jambs (or to fi rst stud in open stud construction), and far

enough below the rough opening to overlap the sill plate or the DuPont™ Tyvek® WRB below. The top of the apron should be securely attached to the wall and the bottom of the apron should be left unsecured so it can overlap the DuPont™ Tyvek® WRB which will be installed after the window.

B. Cut DuPont™ FlexWrap™ NF at least 12” LONGER than width of sill rough opening (S).

C. Remove fi rst piece of release paper, cover horizontal sill by aligning inside edge of sill, and adhere into rough opening across sill and up jambs (min. 6” on each side).

D. Remove second release paper.

E. Fan out DuPont™ FlexWrap™ NF at bottom corners onto the face of the wall. Coverage of DuPont™ FlexWrap™ NF should be 2” to 3” onto the face of the wall.

Page 6: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

A

A

B

B

C

1“ Minimum

INCORRECTDuPont™

FlexWrap™ NF reverse flashed

INCORRECTDuPont™ StraightFlash™

flush with DuPont™ FlexWrap™ NF

CORRECTDuPont™ StraightFlash™

overlaps DuPont™ FlexWrap™ NF

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 6

DuPont™ Flashing Systems Installation Guidelines

STEP 2A. Apply DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended

sealant on three sides (jambs and head) as shown below. If sealant is applied to the sill, ensure that there are at least two (2) 2” gaps in the sealant bead for every 4’ of window to allow for drainage.

STEP 3 - FOR RECTANGULAR WINDOWSA. Install window according to manufacturer’s instructions.

B. Cut two pieces of DuPont™ StraightFlash™, DuPont™ FlexWrap™ NF, or DuPont™ Flashing Tape for jamb fl ashing extending 1” above window head fl ange and below bottom edge of sill fl ashing. Remove release paper and press tightly along sides of window frame.

C. Cut a piece of DuPont™ StraightFlash™, DuPont™ FlexWrap™ NF, or DuPont™ Flashing Tape for head fl ashing, which extends beyond outer edges of jamb fl ashings. Remove release paper and install completely covering fl ange and adhering to exposed sheathing or framing members.

NOTE: Ensure proper shingling. DuPont™ StraightFlash™, DuPont™ Flashing Tape, or DuPont™ FlexWrap™ NF at jambs must overlap the DuPont™ FlexWrap™ NF at the sill and adhere to the DuPont™Tyvek® WRB below the sill.

Page 7: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

6“ Minimum

(H)

Interior

Interior

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 7

DuPont™ Flashing Systems Installation Guidelines

STEP 5Install DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use DuPont™ Window and Door Foam or recommended foam. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. DuPont™ Residential Sealant or DuPont™ Commercial Sealant should be tooled fl at to allow the natural curing process to create a concave shape. Be sure that the sealant penetrates the grooves of the DuPont™ FlexWrap NF™ around the sill.

NOTE: Installations that specify a window/door design rating of DP45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating.

STEP 4 – FOR ROUNDTOP WINDOWSNOTE: Follow rectangular window instructions (Steps 1 through 3B) for proper installation of sill and jamb fl ashing prior to head fl ashing installation.

A. Cut DuPont™ FlexWrap™ NF head fl ashing at least 12” LONGER than the arc length (H) of roundtop window.

B. Remove both release papers and install to conform around top of window, covering entire mounting fl ange and adhering to exposed sheathing or framing members. Head fl ashing should overlap jamb fl ashings by at least 6”.

Page 8: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

DO NOT CUTthrough

DuPont™ Flashing Systems Products

or apron.

Apron made of DuPont™ Tyvek® WRB

DuPont™ FlexWrap™ NF

Window

Place apron over lower layer of

DuPont™ Tyvek® WRB

6” Minimum Overlap

DuPont™ Tyvek® WRB

SIDE VIEW DETAIL

A

A

B

B

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 8

DuPont™ Flashing Systems Installation Guidelines

STEP 6After installing the DuPont™ Tyvek® WRB, cut as shown to expose window and apron. (Refer to the DuPont™ Tyvek® Water-Resistive and Air Barriers Installation Guidelines to install the DuPont™ Tyvek® WRB properly).

DO NOT CUT THROUGH THE DUPONT™ FLASHING SYSTEMS PRODUCTS

OR APRON.

STEP 7Final Step

A. Tape seams as shown. DO NOT TAPE at bottom of window. At the head, continuous tape seams as shown with DuPont™ Tyvek® Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired.

B. Lap bottom of apron and DuPont™ Tyvek® WRB over building materials below for proper shingling.

Page 9: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 9

DuPont™ Flashing Systems Installation Guidelines

ALTERNATE TAPE DETAIL

Place a continuous bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant around the jamb and head fl ashing under the DuPont™ Tyvek® WRB. Press the DuPont™ Tyvek® WRB securely into the sealant.

Round-top WindowRectangular Window

Page 10: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

10“ A

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 10

DuPont™ Flashing Systems Installation Guidelines

Integral Flanged Door BEFORE Water-Resistive Barrier (WRB) is InstalledThis method can be used for doors with fi eld applied fl anges. This installation guideline is intended for doors installed above grade and/or with wood fl oor construction.Method applies to the following products:• DuPont™ StraightFlash™, DuPont™ FlexWrap™ NF and DuPont™ Flashing Tape

STEP 1A. Attach apron made of DuPont™ Tyvek® WRB under sill. Apron should extend at least 10” beyond sides of rough opening

jambs (or to fi rst stud in open stud construction), and far enough below the rough opening to overlap the sill plate or the DuPont™ Tyvek® WRB below. The top of the apron should be securely attached to the wall and the bottom of the apron should be left unsecured so it can overlap the DuPont™ Tyvek® WRB which will be installed after the door.

Page 11: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

6“Minimum

FRONT VIEW CORNER DETAIL

No Gap in Corner

DO NOT STRETCH

WRONG CORRECT

3

4

5

2

1

Door Jamb

DuPont™FlexWrap™ NF

Sill

A

Sill Width+ 12 inches

(S)

A

6-inch for 2x4-inch studs9-inch for 2x6-inch studs

OverlapFront

Back

ScoredReleasePaper

Break ScoredRelease Paper

Peel Off2-piecesof ReleasePaper

B

C

DuPont™FlexWrap™ NF

DuPont™StraightFlash™

DuPont™Tyvek® WRB

Sheathing

High PressureSkirt (See Step6 Optional)

INTERIOR

Door

DoorThreshold

TransitionThreshold

Flooring

Sub Floor

CornerGuard(optional)

EXTERIOR

Optional

SIDE VIEW DETAIL

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 11

DuPont™ Flashing Systems Installation Guidelines

STEP 3A. Install the sill fl ashing as indicated leaving the 1” of DuPont™ FlexWrap™ NF with

release paper extending it past the door threshold on the inside. When the 1” of release paper is removed, there should be 3/4” of fl ashing to form the back dam.

OPTIONAL: Some fl ooring cannot accomodate a back dam. In that case fold the 1” back dam on top of DuPont™ FlexWrap™ NF in the sill. Door will be installed on top of 1” fold to create a back dam (see Side View Detail in Step 7).

STEP 2Preparation of sill fl ashing:

A. Cut 9” DuPont™ FlexWrap™ NF at least 12” LONGER than the width of the sill (S).

B. 9” DuPont™ FlexWrap™ NF has perforated release paper to help with the formation of the back dam. To ensure that the perforation tears cleanly, fold the perforation 180° and crease the fl ashing.

C. Remove the two widest pieces of release paper leaving the narrowest release paper on the fl ashing. When the fi nished fl oor is applied, the release paper can be removed and the back dam can be completed.

Page 12: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

A

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 12

DuPont™ Flashing Systems Installation Guidelines

STEP 4A. Fan out DuPont™ FlexWrap™ NF at bottom corners onto the face of the wall.

Coverage of DuPont™ FlexWrap™ NF should be 2” to 3” onto the face of the wall.

STEP 5Apply DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant on three sides (jambs and head) as shown below. If sealant is applied to the sill, ensure that there are at least two (2) 2” gaps in the sealant bead for every 4’ of window to allow for drainage.

Page 13: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Peel OffRelease Paperand attach tounderside of door

ButylAdhesive

10”

4” DuPont™StraightFlash™

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 13

DuPont™ Flashing Systems Installation Guidelines

STEP 6 (OPTIONAL - HIGH PRESSURE SKIRT)For extreme weather conditions, performance requirements exceeding ASTM E1677, or window/door design ratings of DP45 or greater, see General Instructions.

A. Create the high pressure skirt by cutting a piece of DuPont™ Tyvek® WRB 1” wider than the width of door opening and approximately 10” in depth.

B. Cut a piece of DuPont™ StraightFlash™ or DuPont™ Flashing Tape to the same width as the skirt. Remove release paper from one side of the DuPont™ StraightFlash™ and adhere to the DuPont™ Tyvek® WRB.

C. The skirt may be made with DuPont™ StraightFlash™, DuPont™ Flashing Tape, or DuPont™ StraightFlash™ VF.

Page 14: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

INCORRECTDuPont™

FlexWrap™ NF reverse flashed

INCORRECTDuPont™ StraightFlash™

flush with DuPont™ FlexWrap™ NF

CORRECTDuPont™ StraightFlash™

overlaps DuPont™ FlexWrap™ NF

C

C

A

B

D

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 14

DuPont™ Flashing Systems Installation Guidelines

STEP 7A. OPTIONAL: Adhere high pressure skirt to bottom of threshold of the door.

B. Install door according to manufacturer’s instructions.

C. Cut two pieces of DuPont™ StraightFlash™, DuPont™ FlexWrap™ NF, or DuPont™ Flashing Tape for jamb fl ashing extending 1” above door head fl ange and below bottom edge of high pressure skirt. Remove release paper and press tightly along sides of door frame.

D. Cut a piece of DuPont™ StraightFlash™, DuPont™ FlexWrap™ NF or DuPont™ Flashing Tape for head fl ashing, which extends beyond outer edges of jamb fl ashings. Remove release paper and install completely covering mounting fl ange and adhering to exposed sheathing or framing members.

NOTE: Ensure proper shingling. DuPont™ StraightFlash™, DuPont™ Flashing Tape, or DuPont™ FlexWrap™ NF at jambs must overlap the DuPont™ FlexWrap™ NF at the sill and adhere to the DuPont™ Tyvek® WRB below the sill.

Page 15: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

DO NOT CUTthrough

DuPont Flashing Systems Products

or apron.

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 15

DuPont™ Flashing Systems Installation Guidelines

STEP 8After installing the DuPont™ Tyvek® WRB, cut as shown to expose door and apron. (Refer to the DuPont™ Tyvek® Water-Resistive and Air Barriers Installation Guidelines to install the DuPont™ Tyvek® WRB properly).DO NOT CUT THROUGH THE DUPONT™ FLASHING SYSTEMS PRODUCTS

OR APRON.

STEP 9A. Tape seams as shown. DO NOT TAPE at bottom of window. At the head, continuous

tape seams as shown with DuPont™ Tyvek® Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired.

B. Lap bottom of apron and the DuPont™ Tyvek® WRB over building materials below for proper shingling.

Page 16: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

B

Fold Out and Up

Staples Tape

Fold In and Up

OR

Folding Option One Folding Option Two

Fastening Option One Fastening Option Two

OR

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 16

DuPont™ Flashing Systems Installation Guidelines

ALTERNATE TAPE DETAIL

Place a continuous bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant around the jamb and head fl ashing under the DuPont™ Tyvek®

WRB. Press the DuPont™ Tyvek® WRB securely into the sealant.

STEP 10Final Step

A. When the interior fl ooring is ready to install, remove release paper and use Folding Option One or Two (shown below) to form back dam.

B. Install DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant (and backer rod as necessary) around the door opening at the interior. It is also acceptable to use DuPont™ Window & Door Foam or recommended foam. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. DuPont™ Residential Sealant or DuPont™ Commercial Sealant should be tooled fl at to allow the natural curing process to create a concave shape. Be sure that the sealant penetrates the grooves of the DuPont™ FlexWrap™ NF around the sill.

NOTE: Installations that specify a window/door design rating of DP45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating.

Page 17: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

3

5

21

A

B

E

C

10“6“

Minimum DO NOT STRETCH

4

Sill Width+ 12 inches

(S)

FRONT VIEW CORNER DETAIL

No Gap in Corner

WRONG CORRECT

Door Jamb

DuPont™FlexWrap™ NF

Sill

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 17

DuPont™ Flashing Systems Installation Guidelines

Brick Mold Window BEFORE Water-Resistive Barrier (WRB) Is InstalledThis installation guide can also be used for windows with fi eld applied nailing fi ns and non-fl anged windows.

Method applies to the following products:• DuPont™ StraightFlash™, DuPont™ FlexWrap™ NF, and DuPont™ Flashing Tape

STEP 1 – FOR RECTANGULAR WINDOWS A. Attach apron made of DuPont™ Tyvek® WRB under sill. Apron should extend at least 10” beyond sides of rough opening jambs (or to fi rst stud in open stud

construction), and far enough below the rough opening to overlap the sill plate or the DuPont™ Tyvek® WRB below. The top of the apron should be securely attached to the wall and the bottom of the apron should be left unsecured so it can overlap the DuPont™ Tyvek® WRB which will be installed after the window.

B. Cut DuPont™ FlexWrap™ NF at least 12” longer than width of sill rough opening (S).

C. Remove fi rst piece of release paper, cover horizontal sill by aligning inside edge of sill, and adhere into rough opening across sill and up jambs (min. 6” on each side).

D. Remove second release paper.

E. Fan out DuPont™ FlexWrap™ NF at bottom corners onto the face of the wall. Coverage of DuPont™ FlexWrap™ NF should be 2” to 3” onto the face of the wall.

Page 18: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

WindowInterior

F

G

WindowInterior

WindowInterior

WindowInterior

C

E

E

AB

A

A

VIEW A-A

Brick Mold

Window

Butyl

ScoredReleasePaper

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 18

DuPont™ Flashing Systems Installation Guidelines

STEP 2A. Prepare head fl ashing by cutting a piece of DuPont™ StraightFlash™ VF at least twelve (12) inches LONGER than the head length.

B. Break the scored release paper on one side of the head fl ashing by folding it back and forth upon itself.

C. Center the DuPont™ StraightFlash™ VF along the length of the window head and position so that it contacts the window frame and interior side of the brick mold or fl ange. Remove the outer release paper and adhere the fl ashing to the window frame. Use the inner release paper to form a tight seal in the corner.

D. Remove the inner release paper and adhere the fl ashing to the back of the brick mold or fl ange.

E. Beginning at the junction of the jamb and the head, and away from the corner, cut DuPont™ StraightFlash™ VF at a 45° angle.

F. Fold the newly created fl aps down against the brick mold or fl ange.

G. Fold remaining head fl ashing fl aps down onto the jamb.

Page 19: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Make sure theadhesive on thesepieces willoverlap.

1-1/2”

WindowInterior

WindowInterior

WindowInterior

E

D

C

A

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 19

DuPont™ Flashing Systems Installation Guidelines

STEP 3A. Prepare jamb fl ashing by cutting a piece of DuPont™ StraightFlash™ VF at least six (6) inches LONGER than the jamb.

B. Break the scored release paper on one side of the jamb fl ashing by folding it back and forth upon itself.

C Position so that the DuPont™ StraightFlash™ VF contacts the window frame and interior side of the brick mold or fl ange. Ensure that the jamb fl ashing is positioned 1-1/2 inch below the top edge of the head fl ashing. Jamb fl ashing adhesive must come in contact with head fl ashing

adhesive and overlap one inch.

D. Remove the outer release paper and adhere the fl ashing to the window frame. Use the inner release paper to form a tight seal in the corner.

E. Remove the inner release paper and adhere the fl ashing to the back of the brick mold or fl ange.

F. Repeat on opposite jamb.

Page 20: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

WindowInterior

C

A

A

B

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 20

DuPont™ Flashing Systems Installation Guidelines

STEP 4A. Beginning at the junction of the jamb and the head, and away from the corner, cut

the DuPont™ StraightFlash™ VF at a 45° angle. Repeat the procedure at the junction of the sill and jambs.

B. Fold cut jamb fl ashing parallel to the window frame so that the jamb fl ashing lies fl at.

C. Fold the newly created jamb fl ashing fl aps down at the corners and adhere to the window frame.

Page 21: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

C

A

B

D

B

A

A

A

A

INCORRECTDuPont™

FlexWrap™ NF reverse flashed

INCORRECTDuPont™ StraightFlash™

flush with DuPont™ FlexWrap™ NF

CORRECTDuPont™ StraightFlash™

overlaps DuPont™ FlexWrap™ NF

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 21

DuPont™ Flashing Systems Installation Guidelines

STEP 5A. If sealant is applied to the sill, ensure that there are at least two (2) 2” gaps in the

sealant bead to allow for drainage for every 4’ of window using DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant.

B. Install window according to manufacturer’s installation instructions.

C. Remove the remaining release paper from the DuPont™ StraightFlash™ VF jamb fl ashing and press fi rmly to adhere it to the exterior sheathing or framing members.

D. Remove the release paper at the head and adhere it to the exterior sheathing or framing members.

STEP 6 (OPTIONAL)A. Cover exposed butyl with DuPont™ StraightFlash™, DuPont™ Flashing Tape or

DuPont™ Tyvek® Tape.

B. Cut a piece of metal or vinyl drip cap slightly longer than the width of the window and place a bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant on the rear side. Install the drip cap tight against brick mold and cover the top edge with DuPont™ StraightFlash™ or DuPont™ Flashing Tape.

NOTE: Do not reverse shingle. DuPont™ StraightFlash™ must overlap DuPont™ FlexWrap™ NF and adhere to the substrate.

Page 22: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Interior

DO NOT CUTthrough

DuPont™ Flashing Systems Products

or apron.

Window

6” Minimum Overlap

SIDE VIEW DETAIL

Apron made of DuPont™ Tyvek® WRB

DuPont™ FlexWrap™ NF

Place apron over lower layer of

DuPont™ Tyvek® WRB

DuPont™ Tyvek® WRB

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 22

DuPont™ Flashing Systems Installation Guidelines

STEP 7Install DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use DuPont™ Window & Door Foam or recommended foam. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. DuPont™ Residential Sealant or DuPont™ Commercial Sealant should be tooled fl at to allow the natural curing process to create a concave shape. Be sure that the sealant penetrates the grooves of the DuPont™ FlexWrap™ NF around the sill.

NOTE: Installations that specify a window/door design rating of DP45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating.

STEP 8After installing the DuPont™ Tyvek® WRB, cut as shown to expose window and apron. (Refer to the DuPont™ Tyvek® Water-Resistive and Air Barriers Installation Guidelines to install the DuPont™ Tyvek® WRB properly). DO NOT CUT THROUGH THE DUPONT™ FLASHING SYSTEMS PRODUCTS OR

APRON.

Page 23: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

A

A

A

B

B

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 23

DuPont™ Flashing Systems Installation Guidelines

STEP 9Final Step

A. Tape seams as shown. DO NOT TAPE at bottom of window. At the head, continuous tape seams as shown with DuPont™ Tyvek® Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired.

B. Lap bottom of apron and DuPont™ Tyvek® WRB over building materials below for proper shingling.

ALTERNATE TAPE DETAIL

Place a continuous bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant around the jamb and head fl ashing under the DuPont™ Tyvek®

WRB. Press the DuPont™ Tyvek® WRB securely into the sealant.

Page 24: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

10“

(S)

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 24

DuPont™ Flashing Systems Installation Guidelines

Brick Mold Door BEFORE Water-Resistive Barrier (WRB) Is InstalledThis installation guide is intended for doors installed above grade and with wood fl oor construction.Method applies to the following products:• DuPont™ StraightFlash™, DuPont™ StraightFlash™ VF, DuPont™ FlexWrap™ NF, and DuPont™ Flashing Tape

STEP 1Attach apron made of DuPont™ Tyvek® WRB under sill (S). Apron should extend at least 10” beyond sides of rough opening jambs (or to fi rst stud in open stud construction), and far enough below the rough opening to overlap the sill plate or the DuPont™ Tyvek® WRB below. The top of the apron should be securely attached to the wall and the bottom of the apron should be left unsecured so it can overlap the DuPont™ Tyvek® WRB which will be installed after the door.

Page 25: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

6-inch for 2x4-inch studs9-inch for 2x6-inch studs

Overlap Perf

Break Perf

Peel Off2-piecesof Backing

B

A

C

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 25

DuPont™ Flashing Systems Installation Guidelines

STEP 2Preparation of sill fl ashing:

A. Cut piece of DuPont™ FlexWrap™ NF at least 12” LONGER than the width of the sill (S).

B. DuPont™ FlexWrap™ NF has perforated release paper to help with the formation of the back dam. To ensure that the perforation tears cleanly, fold the perforation 180° and crease the fl ashing.

C. Remove the two widest pieces of release paper leaving the narrowest release paper on the fl ashing. When the fi nished fl oor is applied, the release paper can be removed and the back dam can be completed.

Page 26: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

6“

FRONT VIEW CORNER DETAIL

No Gap in Corner

DO NOT STRETCH

WRONG CORRECT

3

4

5 2

1

Door Jamb

Sill

DuPont™FlexWrap™ NF

DuPont™FlexWrap™ NF

DuPont™StraightFlash™

DuPont™Tyvek® WRB

Sheathing

High PressureSkirt (See Step8 Optional)

INTERIOR

Door

DoorThreshold

TransitionThreshold

Flooring

Sub FloorCornerGuard(optional)

EXTERIOR

Optional

SIDE VIEW DETAIL

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 26

DuPont™ Flashing Systems Installation Guidelines

STEP 3 (OPTIONAL BACK DAM)Install the sill fl ashing as indicated leaving the 1” of DuPont™ FlexWrap™ NF with release paper extending it past the door threshold on the inside. When the 1” of release paper is removed, there should be 3/4” of fl ashing to form the back dam.

OPTION 2: Some fl ooring cannot accomodate a back dam. In that case fold the 1” back dam on top of DuPont™ FlexWrap™ NF in the sill. Door will be installed on top of the 1” fold to create a back dam.

Page 27: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

A

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 27

DuPont™ Flashing Systems Installation Guidelines

STEP 4A. Fan out DuPont™ FlexWrap™ NF at bottom corners onto the face of the wall.

Coverage of DuPont™ FlexWrap™ NF should be 2” to 3” onto the face of the wall.

Page 28: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

VIEW A-A

Brick Mold

Door

Butyl

ScoredReleasePaper

DoorInterior

F G

E

DoorInterior

DoorInterior

DoorInterior

A

C

DA

A

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 28

DuPont™ Flashing Systems Installation Guidelines

STEP 5 (FOR BRICK MOLD DOORS)A. Prepare head fl ashing by cutting a piece of DuPont™ StraightFlash™ VF at least twelve (12) inches LONGER than the head length.

B. Break the scored release paper on one edge of the head fl ashing by folding it back and forth upon itself.

C. Center the DuPont™ StraightFlash™ VF along the length of the door head and position so that it contacts the door frame and interior side of the brick mold or fl ange. Remove the outer release paper and adhere the fl ashing to the door frame. Use the inner release paper to form a tight seal in the corner.

D. Remove the inner release paper and adhere the fl ashing to the back of the brick mold or fl ange.

E. At the corner of the door frame, cut the DuPont™ StraightFlash™ VF at a 45° angle.

F. Fold the newly created fl ashing fl ap down fl at against the brick mold or fl ange.

G. Fold remaining head fl ashing fl aps down onto the jamb frame.

Page 29: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

DoorInterior

DoorInterior

DoorInterior

Make sure theadhesive on thesepieces willoverlap.

1-1/2”

E

D

C

A

1-1/2“

DoorInterior

DoorInterior

DoorInterior

A C

C

C

B

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 29

DuPont™ Flashing Systems Installation Guidelines

STEP 6A. Prepare jamb fl ashing by cutting a piece of DuPont™ StraightFlash™ VF at least six (6)

inches LONGER than the jamb.

B. Break the scored release paper on one side of the jamb fl ashing by folding it back and forth upon itself.

C Position so that DuPont™ StraightFlash™ VF contacts the door frame and interior side of the brick mold or fl ange. Ensure that the jamb fl ashing is positioned 1-1/2 inch below the top edge of the head fl ashing. Jamb fl ashing adhesive must come in

contact with head fl ashing adhesive by one inch.

D. Remove the outer release paper and adhere the fl ashing to the door frame. Use the inner release paper to form a tight seal in the corner.

E. Remove the inner release paper and adhere the fl ashing to the back of the brick mold or fl ange.

F. Repeat on opposite jamb.

STEP 7A. Beginning at the junction of the jamb and head and beginning at the junction of the

jamb and sill, and away from the corner, cut the DuPont™ StraightFlash™ VF along both corners at a 45° angle.

B. Fold newly created fl aps down fl at against the head fl ashing.

C. Fold newly created fl aps down onto the head and sill of door frame.

Page 30: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Peel OffRelease Paperand attachto undersideof door

ButylAdhesive

10”

DuPont™

StraightFlash™ VF

C

B

A

OptionalHigh PressureSkirtD

D

E

F

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 30

DuPont™ Flashing Systems Installation Guidelines

FOR BRICK MOLD

STEP 8 (OPTIONAL - HIGH PRESSURE SKIRT)For extreme weather conditions, performance requirements exceeding ASTM E1677, or window/door design ratings of DP45 or greater, see General Instructions.

A. Create the high pressure skirt by cutting a piece of DuPont™ Tyvek® WRB 1” wider than the width of the door opening and approximately 10” in height.

B. Cut a piece of DuPont™ StraightFlash™ VF to the same width of skirt. Remove release paper from one side of DuPont™ StraightFlash™ VF and adhere to DuPont™ Tyvek® WRB. The skirt may be made with DuPont™ StraightFlash™ VF, DuPont™ StraightFlash™or DuPont™ Flashing Tape.

C. Remove the release paper from the other side of DuPont™ StraightFlash™ VF and adhere the butyl adhesive at the sill skirt to the underside of the door threshold behind the jamb fl ashing.

D. Secure edges of the optional skirt with two 4” pieces of DuPont™ StraightFlash™ or DuPont™ Flashing Tape.

E. Tape the bottom of the optional skirt to allow for drainage and to minimize wind damage during construction.

F. If sealant is applied to the sill, insure (2) 2” gaps to allow for drainage for every 4’ of door using DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant.

Page 31: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

C

B

A

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 31

DuPont™ Flashing Systems Installation Guidelines

STEP 9A. Install door according to manufacturer’s installation instructions.

B. Remove the remaining release paper from the DuPont™ StraightFlash™ VF jamb fl ashing and press fi rmly to adhere it to the exterior sheathing or framing members.

C. Remove the release paper at the head and adhere it to the exterior sheathing or framing members.

OPTIONAL: Cover exposed butyl with DuPont™ StraightFlash™, DuPont™ Flashing Tape or DuPont™ Tyvek® Tape.

STEP 10 (OPTIONAL)A. Cut a piece of metal or vinyl drip cap slightly longer than the width of the door and

place a bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant on the rear side. Install the drip cap tight against the door head and cover the top edge with DuPont™ StraightFlash™ or DuPont™ Flashing Tape.

Page 32: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

DO NOT CUTthrough

DuPont™ Flashing Systems Products

or apron.

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 32

DuPont™ Flashing Systems Installation Guidelines

STEP 11After installing the DuPont™ Tyvek® WRB, cut as shown to expose door and apron. (Refer to the DuPont™ Tyvek® Water-Resistive and Barriers Installation Guidelines to install the DuPont™ Tyvek® WRB properly).

DO NOT CUT THROUGH THE DUPONT™ FLASHING SYSTEMS PRODUCTS OR

APRON.

STEP 12A. Tape seams as shown. DO NOT TAPE at bottom of window. At the head, continuous

tape seams as shown with DuPont™ Tyvek® Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired.

B. Lap bottom of apron and the DuPont™ Tyvek® WRB over building materials below for proper shingling.

Page 33: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Fold Out and Up

Staples Tape

Fold In and Up

OR

OR

Folding Option One Folding Option Two

Fastening Option One Fastening Option Two

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 33

DuPont™ Flashing Systems Installation Guidelines

ALTERNATE TAPE DETAIL

Place a continuous bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant around the jamb and head fl ashing under the DuPont™ Tyvek® WRB. Press the DuPont™ Tyvek® WRB securely into the sealant.

STEP 13Final Step

A. When the interior fl ooring is ready to install, remove release paper and use Folding Option One or Two to form back dam.

B. Install DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use DuPont™ Window & Door Foam or recommended foam. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. DuPont™ Residential Sealant or DuPont™ Commercial Sealant should be tooled fl at to allow the natural curing process to create a concave shape. Be sure that the sealant penetrates the grooves of the DuPont™ FlexWrap™ NF around the sill.

NOTE: Installations that specify a window/door design rating of DP45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating.

Page 34: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

3

5

21

A

B

E

C

10“6“

Minimum DO NOT STRETCH

4

Sill Width+ 12 inches

(S)

FRONT VIEW CORNER DETAIL

No Gap in Corner

WRONG CORRECT

Door Jamb

DuPont™FlexWrap™ NF

Sill

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 34

DuPont™ Flashing Systems Installation Guidelines

Field Applied Flanged Window BEFORE Water-Resistive Barrier (WRB) Is InstalledMethod applies to the following products:• DuPont™ StraightFlash™, DuPont™ StraightFlash™ VF, DuPont™ FlexWrap™ NF and DuPont™ Flashing Tape

STEP 1A. Attach apron made of DuPont™ Tyvek® WRB under sill (S). Apron should extend at least 10” beyond sides of rough opening jambs (or to fi rst stud in open stud

construction), and far enough below the rough opening to overlap the sill plate or the DuPont™ Tyvek® WRB below. The top of the apron should be securely attached to the wall and the bottom of the apron should be left unsecured so it can overlap the DuPont™ Tyvek® WRB which will be installed after the window.

B. Cut DuPont™ FlexWrap™ NF at least 12” longer than width of sill rough opening (S).

C. Remove fi rst piece of release paper, cover horizontal sill by aligning inside edge of sill, and adhere into rough opening across sill and up jambs (min. 6” on each side).

D. Remove second release paper.

E. Fan out DuPont™ FlexWrap™ NF at bottom corners onto the face of the wall. Coverage of DuPont™ FlexWrap™ NF should be 2” to 3” onto the face of the wall.

Page 35: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

1

2

3

4

Exterior

Interior

Note Proper Shingling

Field Applied Flanges

Exterior

Interior

3”x3” DuPont™ FlexWrap™ NF

C

D

B

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 35

DuPont™ Flashing Systems Installation Guidelines

STEP 2A. Apply fi eld applied fl anges in the correct shingling fashion per manufacturer’s installation instructions.

DO NOT REVERSE SHINGLE.

B. Cut four 3”x 3” pieces of DuPont™ FlexWrap™ NF.

C. Apply DuPont™ FlexWrap™ NF patches to back of fl ange corners before applying DuPont™ StraightFlash™ VF.

D. Staple patches in corners and secure to wooden head and jambs.

Page 36: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

WindowInterior

F

E

G

WindowInterior

WindowInterior

WindowInterior

C

A

DA

A VIEW A-A

Window

Butyl

ScoredReleasePaper

Field AppliedFlange

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 36

DuPont™ Flashing Systems Installation Guidelines

STEP 3A. Prepare head fl ashing by cutting a piece of DuPont™ StraightFlash™ VF at least twelve (12) inches LONGER than the head length.

B. Break the scored release paper on one side of the head fl ashing by folding it back and forth upon itself.

C. Center the DuPont™ StraightFlash™ VF along the length of the window head and position so that it contacts the window frame and interior side of the brick mold or fl ange. Remove the outer release paper and adhere the fl ashing to the window frame. Use the inner release paper to form a tight seal in the corner.

D. Remove the inner release paper and adhere the fl ashing to the back of the brick mold or fl ange.

E. Beginning at the junction of the jamb and the head, and away from the corner, cut DuPont™ StraightFlash™ VF at a 45° angle.

F. Fold the newly created fl aps down against the brick mold or fl ange.

G. Fold remaining head fl ashing fl aps down onto the jamb.

Page 37: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Make sure theadhesive on thesepieces willoverlap.

1-1/2”

WindowInterior

WindowInterior

WindowInterior

E

D

C

A

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 37

DuPont™ Flashing Systems Installation Guidelines

STEP 4A. Prepare jamb fl ashing by cutting a piece of DuPont™ StraightFlash™ VF at least six (6) inches LONGER than the jamb.

B. Break the scored release paper on one side of the jamb fl ashing by folding it back and forth upon itself.

C Position so that the DuPont™ StraightFlash™ VF contacts the window frame and interior side of the brick mold or fl ange. Ensure that the jamb fl ashing is positioned 1-1/2 inch below the top edge of the head fl ashing. Jamb fl ashing adhesive must come in contact with head fl ashing

adhesive and overlap one inch.

D. Remove the outer release paper and adhere the fl ashing to the window frame. Use the inner release paper to form a tight seal in the corner.

E. Remove the inner release paper and adhere the fl ashing to the back of the brick mold or fl ange.

F. Repeat on opposite jamb.

Page 38: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

WindowInterior

C

A

A

B

C

A

B

D

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 38

DuPont™ Flashing Systems Installation Guidelines

STEP 5A. Beginning at the junction of the jamb and head, and away from the corner, cut the

DuPont™ Straightfl ash™ VF at a 45° angle. Repeat the procedure at the junction of the sill and jamb.

B. Fold cut jamb fl ashing parallel to the window frame so that the jamb fl ashing lies fl at.

C. Fold remaining jamb fl ashing fl aps down at all corners and adhere to the window frame.

STEP 6A. If sealant is applied to the sill, ensure that there are at least two (2) 2” gaps in the

sealant bead to allow for drainage for every 4’ of window using DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant.

B. Install window according to manufacturer’s installation instructions.

C. Remove the remaining release paper from the DuPont™ StraightFlash™ VF jamb fl ashing and press fi rmly to adhere it to the exterior sheathing or framing members.

D. Remove the release paper at the head and adhere it to the exterior sheathing or framing members.

Page 39: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

B

A

A

A

A

INCORRECTDuPont™

FlexWrap™ NF reverse flashed

INCORRECTDuPont™ StraightFlash™

flush with DuPont™ FlexWrap™ NF

CORRECTDuPont™ StraightFlash™

overlaps DuPont™ FlexWrap™ NF

Interior

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 39

DuPont™ Flashing Systems Installation Guidelines

STEP 6A (OPTIONAL)A. Cover exposed butyl with DuPont™ StraightFlash™, DuPont™ Flashing Tape or

DuPont™ Tyvek® Tape.

B. Cut a piece of metal or vinyl drip cap slightly longer than the width of the window and place a bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant on the rear side. Install the drip cap tight against brick mold and cover the top edge with DuPont™ StraightFlash™ or DuPont™ Flashing Tape.

NOTE: Do not reverse shingle. DuPont™ StraightFlash™ must overlap DuPont™ FlexWrap™ NF and adhere to the substrate.

STEP 7Install DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use DuPont™ Window & Door Foam or recommended foam. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. DuPont™ Residential Sealant or DuPont™ Commercial Sealant should be tooled fl at to allow the natural curing process to create a concave shape. Be sure that the sealant penetrates the grooves of the DuPont™ FlexWrap™ NF around the sill.

NOTE: Installations that specify a window/door design rating of DP45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating.

Page 40: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

DO NOT CUTthrough

DuPont™ Flashing Systems Products

or apron.

Window

6” Minimum Overlap

SIDE VIEW DETAIL

Apron made of DuPont™ Tyvek® WRB

DuPont™ FlexWrap™ NF

Place apron over lower layer of

DuPont™ Tyvek® WRB

DuPont™ Tyvek® WRB

A

A

A

B

B

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 40

DuPont™ Flashing Systems Installation Guidelines

STEP 8After installing the DuPont™ Tyvek® WRB, cut as shown to expose door and apron. (Refer to the DuPont™ Tyvek® Water-Resistive Barriers Installation Guidelines to install the DuPont™ Tyvek® WRB properly). DO NOT CUT THROUGH THE DUPONT™ FLASHING SYSTEMS PRODUCTS

OR APRON.

STEP 9Final Step

A. Tape seams as shown. DO NOT TAPE at bottom of window. At the head, continuous tape seams as shown with DuPont™ Tyvek® Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired.

B. Lap bottom of apron and DuPont™ Tyvek® WRB over building materials below for proper shingling.

Page 41: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 41

DuPont™ Flashing Systems Installation Guidelines

ALTERNATE TAPE DETAIL

Place a continuous bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant around the jamb and head fl ashing under the DuPont™ Tyvek® WRB. Press the DuPont™ Tyvek® WRB securely into the sealant.

Page 42: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

10“

(S)

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 42

DuPont™ Flashing Systems Installation Guidelines

Field Applied Flanged Door BEFORE Water-Resistive Barrier (WRB) Is InstalledThis installation guide is intended for doors installed above grade and with wood fl oor construction.Method applies to the following products:• DuPont™ StraightFlash™, DuPont™ StraightFlash™ VF, DuPont™ FlexWrap™ NF, and DuPont™ Flashing Tape

STEP 1Attach apron made of DuPont™ Tyvek® WRB under sill (S). Apron should extend at least 10” beyond sides of rough opening jambs (or to fi rst stud in open stud construction), and far enough below the rough opening to overlap the sill plate or the DuPont™ Tyvek® WRB below. The top of the apron should be securely attached to the wall and the bottom of the apron should be left unsecured so it can overlap the DuPont™ Tyvek® WRB which will be installed after the door.

Page 43: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

6-inch for 2x4-inch studs9-inch for 2x6-inch studs

OverlapFront

Back

ScoredReleasePaper

Break ScoredRelease Paper

Peel Off2-piecesof ReleasePaper

A

B

C

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 43

DuPont™ Flashing Systems Installation Guidelines

STEP 2Preparation of sill fl ashing:

A. Cut piece of DuPont™ FlexWrap™ NF at least 12” LONGER than the width of the sill (S).

B. DuPont™ FlexWrap™ NF has perforated release paper to help with the formation of the back dam. To ensure that the perforation tears cleanly, fold the perforation 180° and crease the fl ashing.

C. Remove the two widest pieces of release paper leaving the narrowest release paper on the fl ashing. When the fi nished fl oor is applied, the release paper can be removed and the back dam can be completed.

Page 44: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

6“

FRONT VIEW CORNER DETAIL

No Gap in Corner

DO NOT STRETCH

WRONG CORRECT

3

4

5 2

1

Door Jamb

Sill

DuPont™FlexWrap™ NF

DuPont™FlexWrap™ NF

DuPont™StraightFlash™

DuPont™Tyvek® WRB

Sheathing

High PressureSkirt (See Step9 Optional)

INTERIOR

Door

DoorThreshold

TransitionThreshold

Flooring

Sub FloorCornerGuard(optional)

EXTERIOR

Optional

SIDE VIEW DETAIL

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 44

DuPont™ Flashing Systems Installation Guidelines

STEP 3 (OPTIONAL BACKDAM)Install the sill fl ashing as indicated leaving the 1” of DuPont™ FlexWrap™ NF with release paper extending it past the door threshold on the inside. When the 1” of release paper is removed, there should be 3/4” of fl ashing to form the back dam.

OPTION 2: Some fl ooring cannot accomodate a back dam. In that case fold the 1” back dam on top of DuPont™ FlexWrap™ NF in the sill. Door will be installed on top of the 1” fold to create a back dam.

Page 45: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

A

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 45

DuPont™ Flashing Systems Installation Guidelines

STEP 4A. Fan out DuPont™ FlexWrap™ NF at bottom corners onto the face of the wall.

Coverage of DuPont™ FlexWrap™ NF should be 2” to 3” onto the face of the wall.

Page 46: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

1

2

3

4

Exterior

Interior

Note Proper Shingling

Field Applied Flanges

Exterior

Interior

3”x 3” DuPont™ FlexWrap™ NF

DuPont™ FlexWrap™

C

D

B

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 46

DuPont™ Flashing Systems Installation Guidelines

STEP 5 (FOR FIELD APPLIED FLANGED DOORS ONLY)NOTE: This step is not required for Brick Mold DoorsA. Apply fi eld applied fl anges in the correct shingling fashion per manufacturer’s installation instructions. DO NOT REVERSE SHINGLE.

B. Cut four 3” x 3” pieces of DuPont™ FlexWrap™ NF.

C. Apply DuPont™ FlexWrap™ NF patches to back of fl ange corners before applying DuPont™ StraightFlash™ VF.

D. Staple patches in corners and secure to wooden head and jambs.

Page 47: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

VIEW A-A

Window

Butyl

ScoredReleasePaper

Field AppliedFlange

DoorInterior

F G

E

DoorInterior

DoorInterior

DoorInterior

A

C

DA

A

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 47

DuPont™ Flashing Systems Installation Guidelines

STEP 6 (FOR FIELD APPLIED DOORS)A. Prepare head fl ashing by cutting a piece of DuPont™ StraightFlash™ VF at least twelve (12) inches LONGER than the head length.

B. Break the scored release paper on one edge of the head fl ashing by folding it back and forth upon itself.

C. Center the DuPont™ StraightFlash™ VF along the length of the door head and position so that it contacts the door frame and interior side of the brick mold or fl ange. Remove the outer release paper and adhere the fl ashing to the door frame. Use the inner release paper to form a tight seal in the corner.

D. Remove the inner release paper and adhere the fl ashing to the back of the brick mold or fl ange.

E. At the corner of the door frame, cut the DuPont™ StraightFlash™ VF at a 45° angle.

F. Fold the newly created fl ashing fl ap down fl at against the brick mold or fl ange.

G. Fold remaining head fl ashing fl aps down onto the jamb frame.

Page 48: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

DoorInterior

DoorInterior

DoorInterior

Make sure theadhesive on thesepieces willoverlap.

1-1/2”

E

D

C

A

1-1/2“

DoorInterior

DoorInterior

DoorInterior

A C

C

C

B

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 48

DuPont™ Flashing Systems Installation Guidelines

STEP 7A. Prepare jamb fl ashing by cutting a piece of DuPont™ StraightFlash™ VF at least six (6)

inches LONGER than the jamb.

B. Break the scored release paper on one side of the jamb fl ashing by folding it back and forth upon itself.

C Position so that DuPont™ StraightFlash™ VF contacts the door frame and interior side of the brick mold or fl ange. Ensure that the jamb fl ashing is positioned 1-1/2 inch below the top edge of the head fl ashing. Jamb fl ashing adhesive must come in

contact with head fl ashing adhesive by one inch.

D. Remove the outer release paper and adhere the fl ashing to the door frame. Use the inner release paper to form a tight seal in the corner.

E. Remove the inner release paper and adhere the fl ashing to the back of the brick mold or fl ange.

F. Repeat on opposite jamb.

STEP 8A. Beginning at the junction of the jamb and head and beginning at the junction of

the jamb and sill, and away from the corner, cut the DuPont™ StraightFlash™ VF along both corners at a 45° angle.

B. Fold newly created fl aps down fl at against the head fl ashing.

C. Fold newly created fl aps down onto the head and sill of door frame.

Page 49: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Peel OffRelease Paperand attachto undersideof door

ButylAdhesive

10”

DuPont™

StraightFlash™ VF

C

B

A

OptionalHigh PressureSkirtD

D

E

F

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 49

DuPont™ Flashing Systems Installation Guidelines

FOR BRICK MOLD, FIELD APPLIED AND NON-FLANGED DOORS

STEP 9 (OPTIONAL) - HIGH PRESSURE SKIRTFor extreme weather conditions, performance requirements exceeding ASTM E1677, or window/door design ratings of DP45 or greater, see General Instructions.

A. Create the high pressure skirt by cutting a piece ofDuPont™ Tyvek® WRB 1” wider than the width of door opening and approximately 10” in height.

B. Cut a piece of DuPont™ StraightFlash™ VF to the same width of skirt. Remove release paper from one side of DuPont™ StraightFlash™ VF and adhere to DuPont™ Tyvek® WRB. The skirt may be made with DuPont™ StraightFlash™ VF, DuPont™ StraightFlash™or DuPont™ Flashing Tape.

C. Remove the release paper from the other side of DuPont™ StraightFlash™ VF and adhere the butyl adhesive at the sill skirt to the underside of the door threshold behind the jamb fl ashing.

D. Secure edges of the optional skirt with two 4” pieces of DuPont™ StraightFlash™ or DuPont™ Flashing Tape.

E. Tape the bottom of the optional skirt to allow for drainage and to minimize wind damage during construction.

F. If sealant is applied to the sill, insure (2) 2” gaps to allow for drainage for every 4’ of door using DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant.

Page 50: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

C

B

A

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 50

DuPont™ Flashing Systems Installation Guidelines

STEP 10A. Install door according to manufacturer’s installation instructions.

B. Remove the remaining release paper from the DuPont™ StraightFlash™ VF jamb fl ashing and press fi rmly to adhere it to the exterior sheathing or framing members.

C. Remove the release paper at the head and adhere it to the exterior sheathing or framing members.

OPTIONAL: Cover exposed butyl with DuPont™ StraightFlash™, DuPont™ Flashing Tape or DuPont™ Tyvek® Tape.

STEP 11 (OPTIONAL)A. Cut a piece of metal or vinyl drip cap slightly longer than the width of the door and

place a bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant on the rear side. Install the drip cap tight against the door head and cover the top edge with DuPont™ StraightFlash™ or DuPont™ Flashing Tape.

Page 51: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

DO NOT CUTthrough

DuPont™ Flashing Systems Products

or apron.

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 51

DuPont™ Flashing Systems Installation Guidelines

STEP 12After installing the DuPont™ Tyvek® WRB, cut as shown to expose door and apron. (Refer to the DuPont™ Tyvek® Water-Resistive Barriers Installation Guidelines to install the DuPont™ Tyvek® WRB properly).

DO NOT CUT THROUGH THE DUPONT™ FLASHING SYSTEMS PRODUCTS OR

APRON.

STEP 13A. Tape seams as shown. DO NOT TAPE at bottom of window. At the head, continuous

tape seams as shown with DuPont™ Tyvek® Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired.

B. Lap bottom of apron and the DuPont™ Tyvek® WRB over building materials below for proper shingling.

Page 52: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Fold Out and Up

Staples Tape

Fold In and Up

OR

OR

Folding Option One Folding Option Two

Fastening Option One Fastening Option Two

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 52

DuPont™ Flashing Systems Installation Guidelines

ALTERNATE TAPE DETAIL

Place a continuous bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant around the jamb and head fl ashing under the DuPont™ Tyvek® WRB. Press the DuPont™ Tyvek® WRB securely into the sealant.

STEP 14Final Step

A. When the interior fl ooring is ready to install, remove release paper and use Folding Option One or Two to form back dam.

B. Install DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use DuPont™ Window & Door Foam or recommended foam. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. DuPont™ Residential Sealant or DuPont™ Commercial Sealant should be tooled fl at to allow the natural curing process to create a concave shape. Be sure that the sealant penetrates the grooves of the DuPont™ FlexWrap™ NF around the sill.

NOTE: Installations that specify a window/door design rating of DP45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating.

Page 53: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

3

5

21

A

B

E

C

10“6“

Minimum DO NOT STRETCH

4

Sill Width+ 12 inches

(S)

FRONT VIEW CORNER DETAIL

No Gap in Corner

WRONG CORRECT

Door Jamb

DuPont™FlexWrap™ NF

Sill

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 53

DuPont™ Flashing Systems Installation Guidelines

Non-Flanged Window BEFORE Water-Resistive Barrier (WRB) Is InstalledMethod applies to the following products:• DuPont™ StraightFlash™, DuPont™ StraightFlash™ VF, DuPont™ FlexWrap™ NF, and DuPont™ Flashing Tape

STEP 1A. Attach apron made of DuPont™ Tyvek® WRB under sill. Apron should extend at least 10” beyond sides of rough opening jambs (or to fi rst stud in open stud

construction), and far enough below the rough opening to overlap the sill plate or the DuPont™ Tyvek® WRB below. The top of the apron should be securely attached to the wall and the bottom of the apron should be left unsecured so it can overlap the DuPont™ Tyvek® WRB which will be installed after the window.

B. Cut DuPont™ FlexWrap™ NF at least 12” longer than width of sill rough opening (S).

C. Remove fi rst piece of release paper, cover horizontal sill by aligning inside edge of sill, and adhere into rough opening across sill and up jambs (min. 6” on each side).

D. Remove second release paper.

E. Fan out DuPont™ FlexWrap™ NF at bottom corners onto the face of the wall. Coverage of DuPont™ FlexWrap™ NF should be 2” to 3” onto the face of the wall.

Page 54: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

WindowInterior

WindowInterior

WindowInterior

C

D

D

E F

EA

A

A

VIEW A-A

Non-FlangedWindow

Butyl

ScoredReleasePaper

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 54

DuPont™ Flashing Systems Installation Guidelines

A. FOR NON-FLANGED WINDOWS ONLY

STEP 2A. Prepare head fl ashing by cutting a piece of DuPont™ StraightFlash™ VF at least twelve (12) inches LONGER than the head length.

B. Remove the release paper from one side of DuPont™ StraightFlash™ VF.

C. Center the DuPont™ StraightFlash™ VF along the length of the window and position so that it contacts the window frame.

D. At the exterior corners where the window/head frame meets the jamb frame, make 45° cuts into the fl ashing at each and away from the header.

E. Fold the newly created fl ash fl ap down in the vertical direction parallel to the window frame.

F. Fold the fl ashing fl aps down and adhere them to the window frame.

Page 55: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

C

A

B

Make sure theadhesive on thesepieces willoverlap.

1-1/2”

WindowInterior

WindowInterior

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 55

DuPont™ Flashing Systems Installation Guidelines

STEP 3A. Prepare jamb fl ashing by cutting a piece of DuPont™ StraightFlash™ VF at least six (6) inches LONGER than the jamb length.

B. Remove the release paper from one side of DuPont™ StraightFlash™ VF.

C. Position the DuPont™ StraightFlash™ VF so that it contacts the window frame up to the exterior face of the window. Ensure that the jamb fl ashing is positioned 1-1/2 inches below top of head fl ashing. Jamb fl ashing adhesive must come in contact

with head fl ashing adhesive and overlap by one inch.

D. Repeat on opposite jamb.

Page 56: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

1-1/2”

WindowInterior

WindowInterior

WindowInterior

A B D

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 56

DuPont™ Flashing Systems Installation Guidelines

STEP 4A. At the exterior corner of the window, where the window head frame meets the jamb frame, make 45° cuts in the fl ashing

at each end up and away from the head and down away at the sill.

B. Fold the jamb fl ashing pieces parallel to window. Fold newly created fl aps to the jamb frame.

C. Repeat on opposite jamb.

D. Cut four 3”x 3” pieces of DuPont™ FlexWrap™ NF and add patches to corners of the window. Staple to wooden frame for non-fl anged windows.

Page 57: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

C

A

B

D

B

A

A

A

A

INCORRECTDuPont™

FlexWrap™ NF reverse flashed

INCORRECTDuPont™ StraightFlash™

flush with DuPont™ FlexWrap™ NF

CORRECTDuPont™ StraightFlash™

overlaps DuPont™ FlexWrap™ NF

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 57

DuPont™ Flashing Systems Installation Guidelines

STEP 5A. If sealant is applied to the sill, ensure that there are at least two (2) 2” gaps in the

sealant bead to allow for drainage for every 4’ of window using DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant.

B. Install window according to manufacturer’s installation instructions.

C. Remove the remaining release paper from the DuPont™ StraightFlash™ VF jamb fl ashing and press fi rmly to adhere it to the exterior sheathing or framing members.

D. Remove the release paper at the head and adhere it to the exterior sheathing or framing members.

STEP 6 (OPTIONAL)A. Cover exposed butyl with DuPont™ StraightFlash™, DuPont™ Flashing Tape or

DuPont™ Tyvek® Tape.

B. Cut a piece of metal or vinyl drip cap slightly longer than the width of the window and place a bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant on the rear side. Install the drip cap tight against brick mold and cover the top edge with DuPont™ StraightFlash™ or DuPont™ Flashing Tape.

NOTE: Do not reverse shingle. DuPont™ StraightFlash™ must overlap DuPont™ FlexWrap™ NF and adhere to the substrate.

Page 58: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Interior

DO NOT CUTthrough

DuPont™ Flashing Systems Products

or apron.

Window

6” Minimum Overlap

SIDE VIEW DETAIL

Apron made of DuPont™ Tyvek® WRB

DuPont™ FlexWrap™ NF

Place apron over lower layer of

DuPont™ Tyvek® WRB

DuPont™ Tyvek® WRB

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 58

DuPont™ Flashing Systems Installation Guidelines

STEP 7Install DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use DuPont™ Window & Door Foam or recommended foam. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. DuPont™ Residential Sealant or DuPont™ Commercial Sealant should be tooled fl at to allow the natural curing process to create a concave shape. Be sure that the sealant penetrates the grooves of the DuPont™ FlexWrap™ NF around the sill.

NOTE: Installations that specify a window/door design rating of DP45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating.

STEP 8After installing the DuPont™ Tyvek® WRB, cut as shown to expose window and apron. (Refer to the DuPont™ Tyvek® Water-Resistive Barriers Installation Guidelines to install the DuPont™ Tyvek® WRB properly). DO NOT CUT THROUGH THE DUPONT™ FLASHING SYSTEMS PRODUCTS OR

APRON.

Page 59: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

A

A

A

B

B

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 59

DuPont™ Flashing Systems Installation Guidelines

STEP 9Final Step

A. Tape seams as shown. DO NOT TAPE at bottom of window. At the head, continuous tape seams as shown with DuPont™ Tyvek® Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired.

B. Lap bottom of apron and DuPont™ Tyvek® WRB over building materials below for proper shingling.

ALTERNATE TAPE DETAIL

Place a continuous bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant around the jamb and head fl ashing under the DuPont™ Tyvek® WRB. Press the DuPont™ Tyvek® WRB securely into the sealant.

Page 60: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

10“

(S)

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 60

DuPont™ Flashing Systems Installation Guidelines

Non-Flanged Door BEFORE Water-Resistive Barrier (WRB) Is InstalledThis installation guide is intended for doors installed above grade and with wood fl oor construction.Method applies to the following products:• DuPont™ StraightFlash™, DuPont™ StraightFlash™ VF, DuPont™ FlexWrap™ NF, and DuPont™ Flashing Tape

STEP 1Attach apron made of DuPont™ Tyvek® WRB under sill (S). Apron should extend at least 10” beyond sides of rough opening jambs (or to fi rst stud in open stud construction), and far enough below the rough opening to overlap the sill plate or the DuPont™ Tyvek® WRB below. The top of the apron should be securely attached to the wall and the bottom of the apron should be left unsecured so it can overlap the DuPont™ Tyvek® WRB which will be installed after the door.

Page 61: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

6-inch for 2x4-inch studs9-inch for 2x6-inch studs

Overlap Perf

Break Perf

Peel Off2-piecesof Backing

B

A

C

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 61

DuPont™ Flashing Systems Installation Guidelines

STEP 2Preparation of sill fl ashing:

A. Cut piece of DuPont™ FlexWrap™ NF at least 12” LONGER than the width of the sill (S).

B. DuPont™ FlexWrap™ NF has perforated release paper to help with the formation of the back dam. To ensure that the perforation tears cleanly, fold the perforation 180° and crease the fl ashing.

C. Remove the two widest pieces of release paper leaving the narrowest release paper on the fl ashing. When the fi nished fl oor is applied, the release paper can be removed and the back dam can be completed.

Page 62: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

6“

FRONT VIEW CORNER DETAIL

No Gap in Corner

DO NOT STRETCH

WRONG CORRECT

3

4

5 2

1

Door Jamb

Sill

DuPont™FlexWrap™ NF

DuPont™FlexWrap™ NF

DuPont™StraightFlash™

DuPont™Tyvek® WRB

Sheathing

High PressureSkirt (See Step8 Optional)

INTERIOR

Door

DoorThreshold

TransitionThreshold

Flooring

Sub FloorCornerGuard(optional)

EXTERIOR

Optional

SIDE VIEW DETAIL

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 62

DuPont™ Flashing Systems Installation Guidelines

STEP 3 (OPTIONAL BACK DAM)Install the sill fl ashing as indicated leaving the 1” of DuPont™ FlexWrap™ NF with release paper extending it past the door threshold on the inside. When the 1” of release paper is removed, there should be 3/4” of fl ashing to form the back dam.

OPTION 2: Some fl ooring cannot accomodate a back dam. In that case fold the 1” back dam on top of DuPont™ FlexWrap™ NF in the sill. Door will be installed on top of the 1” fold to create a back dam.

Page 63: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

A

DoorInterior

DoorInterior

DoorInterior

C

D

D

E F

EA

A

A

VIEW A-A

Non-FlangedDoor

Butyl

ScoredReleasePaper

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 63

DuPont™ Flashing Systems Installation Guidelines

STEP 4A. Fan out DuPont™ FlexWrap™ NF at bottom corners onto the face of the wall.

Coverage of DuPont™ FlexWrap™ NF should be 2” to 3” onto the face of the wall.

A. FOR NON-FLANGED DOORS ONLY

STEP 5A. Prepare head fl ashing by cutting a piece of DuPont™ StraightFlash™ VF at least

twelve (12) inches LONGER than the head length.

B. Remove the release paper from one side of DuPont™ StraightFlash™ VF.

C. Center the DuPont™ StraightFlash™ VF along the length of the door and position so that it contacts the door frame.

D. Beginning at the junction of the jamb and head and away from the corners cut the DuPont™ Straightfl ash™ VF along the corner at a 45° angle.

E. Fold the newly created fl ashing fl aps down parallel to the door frame.

F. Fold remaining head fl ashing onto to the jamb.

Page 64: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

C

A

B

DoorInterior

DoorInterior

1-1/2”

Make sure theadhesive on thesepieces willoverlap.

1-1/2“

DoorInterior

DoorInterior

DoorInterior

A C

C

C

B

Exterior

Interior

3”x 3” DuPont™ FlexWrap™ NF

E

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 64

DuPont™ Flashing Systems Installation Guidelines

STEP 6A. Prepare jamb fl ashing by cutting a piece of DuPont™ StraightFlash™ VF at least six (6)

inches LONGER than the jamb length.

B. Remove the release paper from one side of DuPont™ StraightFlash™ VF.

C. Position so that the DuPont™ StraightFlash™ VF contacts the door frame up to the exterior face of the door. Ensure that the jamb fl ashing is positioned 1-1/2 inches below top of head fl ashing. Jamb fl ashing adhesive must come in contact with

head fl ashing adhesive and overlap by one inch.

D. Repeat on opposite jamb.

STEP 7A. Beginning at the junction of the jamb and head

and at the sill and jamb and away from the corners, cut the DuPont™ Straightfl ash™ VF along the corners at a 45° angle and fold it over fl at to adhere it against the head fl ashing.

B. Fold newly created fl ap down parallel to the door frame.

C. Fold fl ashing fl aps to the door frame and adhere.

D. Repeat on opposite jamb.

E. Cut two 3” x 3 DuPont™ FlexWrap™ NF squares and add patches to corner of the door. Staple patches in corners to secure the wooden head and jambs.

Page 65: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Peel OffRelease Paperand attachto undersideof door

ButylAdhesive

10”

DuPont™

StraightFlash™ VF

C

B

A

OptionalHigh PressureSkirtD

D

E

F

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 65

DuPont™ Flashing Systems Installation Guidelines

FOR NON-FLANGED DOORS

STEP 8 (OPTIONAL - HIGH PRESSURE SKIRT)For extreme weather conditions, performance requirements exceeding ASTM E1677, or window/door design ratings of DP45 or greater, see General Instructions.

A. Create the high pressure skirt by cutting a piece of DuPont™ Tyvek® WRB 1” wider than the width of the door opening and approximately 10” in height.

B. Cut a piece of DuPont™ StraightFlash™ VF to the same width of skirt. Remove release paper from one side of DuPont™ StraightFlash™ VF and adhere to the DuPont™ Tyvek® WRB. The skirt may be made with DuPont™ StraightFlash™ VF, DuPont™ StraightFlash™or DuPont™ Flashing Tape.

C. Remove the release paper from the other side of DuPont™ StraightFlash™ VF and adhere the butyl adhesive at the sill skirt to the underside of the door threshold behind the jamb fl ashing.

D. Secure edges of the optional skirt with two 4” pieces of DuPont™ StraightFlash™ or DuPont™ Flashing Tape.

E. Tape the bottom of the optional skirt to allow for drainage and to minimize wind damage during construction.

F. If sealant is applied to the sill, insure (2) 2” gaps to allow for drainage for every 4’ of door using DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant.

Page 66: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

C

B

A

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 66

DuPont™ Flashing Systems Installation Guidelines

STEP 9A. Install door according to manufacturer’s installation instructions.

B. Remove the remaining release paper from the DuPont™ StraightFlash™ VF jamb fl ashing and press fi rmly to adhere it to the DuPont™ Tyvek® WRB.

C. Remove the release paper at the head and adhere it to the exterior sheathing or framing members.

OPTIONAL: Cover exposed butyl with DuPont™ StraightFlash™, DuPont™ Flashing Tape or DuPont™ Tyvek® Tape.

STEP 10 (OPTIONAL - RECOMMENDED BEST PRACTICE)A. Cut a piece of metal or vinyl drip cap slightly longer than the width of the door and

place a bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant on the rear side. Install the drip cap tight against the door head and cover the top edge with DuPont™ StraightFlash™ or DuPont™ Flashing Tape.

Page 67: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

DO NOT CUTthrough

DuPont™ Flashing Systems Products

or apron.

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 67

DuPont™ Flashing Systems Installation Guidelines

STEP 11After installing the DuPont™ Tyvek® WRB, cut as shown to expose door and apron. (Refer to the DuPont™ Tyvek® Water-Resistive Barriers Installation Guidelines to install the DuPont™ Tyvek® WRB properly).

DO NOT CUT THROUGH THE DUPONT™ FLASHING SYSTEMS PRODUCTS OR

APRON.

STEP 12A. Tape seams as shown. DO NOT TAPE at bottom of window. At the head, continuous

tape seams as shown with DuPont™ Tyvek® Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired.

B. Lap bottom of apron and the DuPont™ Tyvek® WRB over building materials below for proper shingling.

Page 68: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Fold Out and Up

Staples Tape

Fold In and Up

OR

OR

Folding Option One Folding Option Two

Fastening Option One Fastening Option Two

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 68

DuPont™ Flashing Systems Installation Guidelines

ALTERNATE TAPE DETAIL

Place a continuous bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant around the jamb and head fl ashing under the DuPont™ Tyvek® WRB. Press the DuPont™ Tyvek® WRB securely into the sealant.

STEP 13Final Step

A. When the interior fl ooring is ready to install, remove release paper and use Folding Option One or Two to form back dam.

B. Install DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use DuPont™ Window & Door Foam or recommended foam. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. DuPont™ Residential Sealant or DuPont™ Commercial Sealant should be tooled fl at to allow the natural curing process to create a concave shape. Be sure that the sealant penetrates the grooves of the DuPont™ FlexWrap™ NF around the sill.

NOTE: Installations that specify a window/door design rating of DP45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating.

Page 69: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

4“

A

18“

18“

18“

18“

B

A

C

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 69

DuPont™ Flashing Systems Installation Guidelines

METHOD MODIFIED FULL AIR BARRIER HEAD DETAIL FOR DRAINAGE

STEP 1

A. Apply a continuous bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant around jambs and head, angle the sealant to create a 4” peak.

Alternate head detail For Air Barrier Installations (integral, fl anged, brick mold, fi eld applied and non-fl anged windows and doors)

STEP 2

A. Cut a piece of DuPont™ Tyvek® WRB that overlaps the window opening by 18”.

B. Press the cut piece of DuPont™ Tyvek® WRB into the sealant, maintaining an 18” overlap on all sides of the opening, and attach with fasteners.

C. Cut opening as shown ensuring an 18” overlap of DuPont™ Tyvek® WRB.

Page 70: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

A

B

A

B

B

6“ min.

6“ min.

6“

View A-A

6“

View A-A

6“ min.

6“ min.

2“ min.overlap

past edgeof cut 2“ min.

overlappast edgeof cut

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 70

DuPont™ Flashing Systems Installation Guidelines

STEP 3

A. Fold head and jamb fl aps into rough opening.

B. Secure fl aps to inside wall framing using staples. Cut off excess fl aps if desired.

STEP 4

A. Install DuPont™ FlexWrap™ NF at the sill.

B. Install a minimum of 12” DuPont™ FlexWrap™ NF corners at the head.

A longer piece of DuPont™ FlexWrap™ may be required to properly cover the exposed areas of the opening to establish a 2” minimum overlap past edge of cut. See detail View A-A.

Page 71: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

BA

C

C

D

INCORRECTDuPont™

FlexWrap™ NF reverse flashed

INCORRECTDuPont™ StraightFlash™

flush with DuPont™ FlexWrap™ NF

CORRECTDuPont™ StraightFlash™

overlaps DuPont™ FlexWrap™ NF

Interior

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 71

DuPont™ Flashing Systems Installation Guidelines

STEP 5A. Apply DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended

sealant on three sides (jambs and head) as shown below. If sealant is applied to the sill, ensure that there are at least two (2) 2” gaps in the sealant bead for every 4’ of window to allow for drainage.

B. Install window according to manufacturer’s instructions.

C. Cut two pieces of DuPont™ StraightFlash™, DuPont™ FlexWrap™ NF or DuPont™ Flashing Tape for jamb fl ashing extending 1” above window head fl ange and below bottom edge of sill fl ashing. Remove release paper and press tightly along sides of window frame.

D. Cut a piece of DuPont™ StraightFlash™, DuPont™ FlexWrap™ NF or DuPont™ Flashing Tape for head fl ashing, which should extend beyond the outer edges of the jamb fl ashings. Remove release paper and install to completely cover fl ange while also adhering to the face of the wall.

NOTE: Ensure proper shingling. DuPont™ StraightFlash™ or DuPont™ Flashing Tape must overlap DuPont™ FlexWrap™ NF and adhere to the DuPont™ Tyvek® WRB.

STEP 6Install DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use DuPont™ Window & Door Foam or recommended foam. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. DuPont™ Residential Sealant or DuPont™ Commercial Sealant should be tooled fl at to allow the natural curing process to create a concave shape. Be sure that the sealant penetrates the grooves of the DuPont™ FlexWrap NF™ around the sill.

NOTE: Installations that specify a window/door design rating of DP45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating.

Page 72: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

DO NOT CUTthrough

DuPont™ Flashing Systems Products

or apron.

Apron made of DuPont™ Tyvek® WRB

DuPont™ FlexWrap™ NF

Window

Place apron over lower layer of

DuPont™ Tyvek® WRB

6” Minimum Overlap

DuPont™ Tyvek® WRB

SIDE VIEW DETAIL

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 72

DuPont™ Flashing Systems Installation Guidelines

STEP 7After installing the DuPont™ Tyvek® WRB, cut as shown to expose 1” of fl ashing around the window frame as shown. (Refer to the DuPont™ Tyvek® Water-Resistive and Air Barriers Installation Guidelines to install the DuPont™ Tyvek® WRB properly).

DO NOT CUT THROUGH THE DUPONT™ FLASHING SYSTEMS PRODUCTS

OR APRON.

STEP 8Final Step

A. Tape seams as shown. DO NOT TAPE at bottom of window. At the head, continuous tape seams as shown with DuPont™ Tyvek® Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired.

B. Lap bottom of apron and DuPont™ Tyvek® WRB over building materials below for proper shingling.

Page 73: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 73

DuPont™ Flashing Systems Installation Guidelines

ALTERNATE TAPE DETAIL

Place a continuous bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant around the jamb and head fl ashing under the DuPont™ Tyvek® WRB. Press the DuPont™ Tyvek® WRB securely into the sealant.

Page 74: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

B

A

12“ min.

Sill width +24“

12“ min.

12“ min.

4“

A

18“

18“

18“

18“

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 74

DuPont™ Flashing Systems Installation Guidelines

STEP 1

A. Prepare DuPont™ Tyvek® WRB apron and fasten as shown.

B. Install continuous bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant around jambs and head, angle the sealant to create a 4” peak.

STEP 2

A. Install DuPont™ Tyvek® WRB pieces, wrapping the DuPont™ Tyvek® WRB in and around the studs in at the jamb and head, pressing the pieces of DuPont™ Tyvek® WRB into the sealant. Staple DuPont™ Tyvek® WRB to inside framing to secure.

OPTIONAL HEAD DETAIL TO MEET SPECIFIC AIR BARRIER STANDARDS

Page 75: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

A

B

B

6“ min.

6“ min.

6“ min.

B

C

C

D

A

1“ Minimum

INCORRECTDuPont™

FlexWrap™ NF reverse flashed

INCORRECTDuPont™ StraightFlash™

flush with DuPont™ FlexWrap™ NF

CORRECTDuPont™ StraightFlash™

overlaps DuPont™ FlexWrap™ NFCopyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 75

DuPont™ Flashing Systems Installation Guidelines

STEP 3

A. Cut DuPont™ FlexWrap™ NF at least 12” LONGER than width of the sill rough opening. Remove the fi rst piece of release paper, cover the sill by aligning the DuPont™ FlexWrap™ NF to the inside edge of sill, and adhere into rough opening along sill and up jambs (min. 6” on each side). Remove second release paper. Fan out DuPont™ FlexWrap™ NF at bottom corners onto the face of wall. Coverage of DuPont™ FlexWrap™ NF should be 2” to 3” onto the face of the wall.

B. Apply a minimum of 12” length of DuPont™ FlexWrap™ NF at each corner of the head, going 6” down the jamb and at least 6” on the head as shown.

STEP 4A. Apply DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended

sealant on three sides (jambs and head) as shown below. If sealant is applied to the sill, ensure that there are at least two (2) 2” gaps in the sealant bead for every 4’ of window to allow for drainage.

B. Install window according to manufacturer’s instructions.

C. Cut two pieces of DuPont™ StraightFlash™, DuPont™ FlexWrap™ NF or DuPont™ Flashing Tape for jamb fl ashing extending 1” above window head fl ange and below bottom edge of sill fl ashing. Remove release paper and press tightly along sides of window frame.

D. Cut a piece of DuPont™ StraightFlash™, DuPont™ FlexWrap™ NF or DuPont™ Flashing Tape for head fl ashing, which extends beyond outer edges of jamb fl ashings. Remove release paper and install completely covering mounting fl ange and adhering to the DuPont™ Tyvek® WRB pieces.

NOTE: Ensure proper shingling. DuPont™ StraightFlash™ or DuPont™ Flashing Tape must overlap DuPont™ FlexWrap™ NF and adhere to the DuPont™ Tyvek® WRB.

Page 76: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Interior

DO NOT CUTthrough

DuPont™ Flashing Systems Products

or apron.

Apron made of DuPont™ Tyvek® WRB

DuPont™ FlexWrap™ NF

Window

Place apron over lower layer of

DuPont™ Tyvek® WRB

6” Minimum Overlap

DuPont™ Tyvek® WRB

SIDE VIEW DETAIL

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 76

DuPont™ Flashing Systems Installation Guidelines

STEP 5Install DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use DuPont™ Window & Door Foam or recommended foam. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. DuPont™ Residential Sealant or DuPont™ Commercial Sealant should be tooled fl at to allow the natural curing process to create a concave shape. Be sure that the sealant penetrates the grooves of the DuPont™ FlexWrap™ NF around the sill.

NOTE: Installations that specify a window/door design rating of DP45 or greater require

extra precautions. See General Instructions for performance requirements exceeding

this design rating.

STEP 6A. After installing the DuPont™ Tyvek® WRB, cut as shown to expose 1” of fl ashing

around the window frame and apron. (Refer to the DuPont™ Tyvek® Water-Resistive and Air Barriers Installation Guidelines to install the DuPont™ Tyvek® WRB properly).

DO NOT CUT THROUGH THE DUPONT™ FLASHING SYSTEMS PRODUCTS

OR APRON.

Page 77: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 77

DuPont™ Flashing Systems Installation Guidelines

STEP 7Final Step

A. Tape seams as shown. DO NOT TAPE at bottom of window. At the head, continuous tape seams as shown with DuPont™ Tyvek® Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired.

B. Lap bottom of apron and DuPont™ Tyvek® WRB over building materials below for proper shingling.

Page 78: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

10”10”

A

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 78

DuPont™ Flashing Systems Installation Guidelines

Integral Flanged Window in Recessed Windows BEFORE Water-Resistive Barrier (WRB) is Installed

Method applies to the following products:DuPont™ FlexWrap™ RW, DuPont™ FlexWrap™ NF and DuPont™ StraightFlash™

NOTE: This installation guide shows a double stud application. If using single stud application use DuPont™ FlexWrap™ RW for single stud construction and follow the same techniques.

STEP 1Prepare WRB for window installation:

A. Attach apron made of DuPont™ Tyvek® WRB under sill. Apron should extend at least 10” beyond sides of rough opening jambs (or to fi rst stud in open stud construction), and far enough below the rough opening to overlap the sill plate or the DuPont™ Tyvek® WRB below. The top of the apron should be securely attached to wall and the bottom of apron should be left free to overlap later with the DuPont™ Tyvek® WRB installation.

Page 79: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

AB

C

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 79

DuPont™ Flashing Systems Installation Guidelines

STEP 2Make four corners for the recessed window:

A. Remove DuPont™ FlexWrap™ RW and hold the corner with the attached adhesive with the fi rst and third fi nger.

B. Place index fi nger on tip of upper edge of adhered butyl and pinch butyl triangle at the base with thumb and middle fi nger.

C. Using the other hand, invert fl ashing to form a three-dimensional corner.

D. Repeat three more times for three remaining corner pieces.

Page 80: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

1

2

3

4

2

1

3

4

1

1

23

4

4

5

56

Note Proper Overlap

1

2

3

4

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 80

DuPont™ Flashing Systems Installation Guidelines

STEP 3A. Once inverted, fold 1 and 2 towards the crease line and complete the folding process by folding section 3 onto 4.

CORRECT SHINGLINGCORRECT ORDER OF PRODUCT INSTALLATION

NOTE: Please refer to this diagram as you proceed for proper installation. An accepted variation to theschematic would be to install the DuPont™ StraightFlash™ at the sill and head before therespective corners (i.e., placing Step 2 before Step 1 and Step 6 before Step 5). Any other sequence deviation

from the above described process is incorrect.

Page 81: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

A

3

4

2

1

FRONT VIEW CORNER DETAIL

No Gap in Corner

WRONG CORRECT

Window Jamb

Sill

DuPont™FlexWrap™ RW

B

C

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 81

DuPont™ Flashing Systems Installation Guidelines

STEP 4A. Remove release paper fi rst from either side 3 or side 4 – but not both.

NOTE: Keeping the remaining release papers intact will keep the DuPont™ FlexWrap™ RW more rigid and help to maneuver the fl ashing into the corners.

B. Place prepared DuPont™ FlexWrap™ RW tightly into corner of outer sill. Once in place, lift exposed butyl and adhere to window jamb.

C. Lift the remaining side and remove second piece of release paper exposing butyl. Fold down and attach butyl to sill.

Page 82: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

1

2

A

B

C

D

E

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 82

DuPont™ Flashing Systems Installation Guidelines

STEP 5A. Fold fl aps 1 and 2 and remove both pieces of release paper. Adhere butyl to inner recessed sill plate.

B. Fan out outer corners of the DuPont™ FlexWrap™ RW and tack corners on to the face of the wall in three places using recommended fasteners.

C. Place a bead of DuPont™ Residential Sealant , DuPont™ Commercial Sealant, or recommended sealant inside the corner fl ap behind the loose triangular fl ap of the corner piece.

D. Press down the loose triangular fl ap onto sealant in the corner piece.

E. Staple down fl ap.

Page 83: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

CB

A

D

S

FRONT VIEW CORNER DETAIL

No Gap in Corner

WRONG CORRECT

Window Jamb

DuPont™FlexWrap™ NF

Sill

X

6” Minimum

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 83

DuPont™ Flashing Systems Installation Guidelines

STEP 6A. Using 9” width DuPont™ StraightFlash™, cut the length of the fl ashing slightly

SHORTER than the length of the outer sill (S).

B. Break all the perforations on the release paper by folding the fl ashing. If some perforations do not break, apply pressure with fi ngers to the area on the opposite side to break the remaining perforations.

NOTE: Failure to break all perforations will result in tearing of the release paper during its removal thereby making the installation diffi cult.

C. Fold in, remove center release paper and adhere to sill.

D. Unfold remaining DuPont™ StraightFlash™, remove remaining pieces of release paper and adhere butyl adhesive side to face of recessed sill and to face of the DuPont™ Tyvek® WRB.

STEP 7A. Cut DuPont™ FlexWrap™ NF at least 12” LONGER than width of inner/recessed

sill (X).

B. Remove fi rst piece of release paper. Cover horizontal sill by aligning inside edge of sill, and adhere into rough opening along sill and up jambs (min. 6” on each side).

C. Remove second release paper.

D. Fan out DuPont™ FlexWrap™ NF at bottom corners onto the face of the wall. Coverage of DuPont™ FlexWrap™ NF should be 2” to 3” onto the face of the framing.

Page 84: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

A

B

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 84

DuPont™ Flashing Systems Installation Guidelines

STEP 8A. Apply DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant on three sides (jambs and head) as

shown below. If sealant is applied to the sill, ensure that there are at least two (2) 2” gaps in the sealant bead for every 4’ of window to allow for drainage.

B. Install window per manufacturer’s instructions.

Page 85: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

X

B

C

A

B

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 85

DuPont™ Flashing Systems Installation Guidelines

STEP 9A. Fold 9” DuPont™ StraightFlash™ to break all of the perforations on the release paper.

If some perforations do not break, apply pressure with fi ngers to the area on the opposite side to break the remaining perforations.

NOTE: Failure to break all perforations will result in tearing of the release paper during its removal making the installation diffi cult.

B. Fold DuPont™ StraightFlash™ into three sections and remove only the center release paper. Place exposed butyl adhesive side onto the jamb.

C. Once the butyl is adhered to the rough opening of the jamb, the two remaining release papers can be removed and the fl ashing can be attached to the window fl ange and onto the face of the exterior sheathing.

D. Repeat on opposite jamb.

STEP 10A. Install DuPont™ FlexWrap™ RW on the upper corner of the window rough opening onto

the window fl anges in a similar manner used on lower corner pieces. (see Step 4)

B. Fan out outer corners of the DuPont™ FlexWrap™ RW and tack corners on to the face of the wall in three places using recommended fasteners.

Page 86: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

A

B

C

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 86

DuPont™ Flashing Systems Installation Guidelines

STEP 11A. Place a bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant on underside

behind corner fl ap of loose triangular fl ap in corner.

B. Press down loose triangle fl aps onto the sealant in the corner piece.

C. Staple down fl ap after applying the sealant behind fl ap.

Page 87: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Y

Interior

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 87

DuPont™ Flashing Systems Installation Guidelines

STEP 12A. Cut a piece of 9” width DuPont™ StraightFlash™ one inch (1”) SHORTER than

distance of “Y“.

B. Break perforation lines as described in jamb and sill instructions. (see Step 9)

C. Remove the outer pieces of release paper.

D. Place on window fl ange.

E. Remove inner piece of release paper and adhere to the head.

F. Remove last and outer piece of release paper and adhere to exterior sheathing.

STEP 13Install DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use DuPont™ Window & Door Foam or recommended foam. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. DuPont™ Residential Sealant or DuPont™ Commercial Sealant should be tooled fl at to allow the natural curing process to create a concave shape. Be sure that the sealant penetrates the grooves of the DuPont™ FlexWrap™ NF around the sill.

NOTE: Installations that specify a window/door design rating of DP45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating.

Page 88: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

DO NOT CUTthrough

DuPont™ Flashing Systems Products

or apron.

Apron made of DuPont™ Tyvek® WRB

9” DuPont™ FlexWrap™ NF

DuPont™ StraightFlash™

DuPont™ FlexWrap™ RW

Window

Place apron over lower layer of DuPont™ Tyvek® WRB

6” Minimum Overlap

DuPont™ Tyvek® WRB

SIDE VIEW DETAIL

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 88

DuPont™ Flashing Systems Installation Guidelines

STEP 14After installing the DuPont™ Tyvek® WRB, cut as shown to expose window and apron. (Refer to the DuPont™ Tyvek® Water-Resistive Barriers Installation Guidelines to install the DuPont™ Tyvek® WRB properly).

DO NOT CUT THROUGH THE

DUPONT™ FLASHING SYSTEMS

PRODUCTS OR APRON.

STEP 15Final Step

A. Tape seams as shown. DO NOT TAPE at bottom of window. At the head, continuous tape seams as shown with DuPont™ Tyvek® Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired.

B. Lap bottom of apron and the DuPont™ Tyvek® WRB over building materials below for proper shingling.

Page 89: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 89

DuPont™ Flashing Systems Installation Guidelines

ALTERNATE TAPE DETAIL

Place a continuous bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant around the jamb and head fl ashing under the DuPont™ Tyvek®

WRB. Press the DuPont™ Tyvek®WRB securely into the sealant.

Page 90: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

10”

10”

A

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 90

DuPont™ Flashing Systems Installation Guidelines

Integral Flanged Window in Recessed Openings with Open Stud Construction BEFORE Water-Resistive Barrier (WRB) is Installed

Method applies to the following products:DuPont™ FlexWrap™ RW, DuPont™ FlexWrap™ NF and DuPont™ StraightFlash™

NOTE: This installation guide shows a double stud application. If using single stud application, use DuPont™ FlexWrap™ RW for single stud construction and follow the same techniques.

STEP 1 – FOR RECTANGULAR WINDOWS A. Attach apron made of DuPont™ Tyvek® WRB under sill. Apron should extend at least

10” beyond sides of rough opening jambs (or to fi rst stud in open stud construction), and far enough below the rough opening to overlap the sill plate or the DuPont™ Tyvek® WRB below. The top of the apron should be securely attached to wall and the bottom of apron should be left free to overlap later with DuPont™ Tyvek® WRB installation.

Page 91: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

AB

C

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 91

DuPont™ Flashing Systems Installation Guidelines

STEP 2Make four corners for the recessed window:

A. Remove DuPont™ FlexWrap™ RW and hold the corner with the attached adhesive with the fi rst and third fi nger.

B. Place index fi nger on tip of upper edge of adhered butyl and pinch butyl triangle at the base with thumb and middle fi nger.

C. Using the other hand, invert fl ashing to form a three-dimensional corner.

D. Repeat three more times for three remaining corner pieces.

Page 92: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

1

1

23

4

4

5

56

Note Proper Overlap

1

2

3

4

2

1

3

4

1

2

3

4

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 92

DuPont™ Flashing Systems Installation Guidelines

STEP 3A. Once inverted, fold 1 and 2 towards the crease line and complete the folding process by folding section 3 onto 4.

CORRECT SHINGLINGCORRECT ORDER OF PRODUCT INSTALLATION

NOTE: Please refer to this diagram as you proceed for proper installation. An accepted variation to the schematic would be to install the DuPont™ StraightFlash™ at the sill and head before the respective corners (i.e., placing Step 2 before Step 1 and Step 6 before Step 5). Any other sequence deviation from

the above described process is incorrect.

Page 93: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

A

3

4

2

1

FRONT VIEW CORNER DETAIL

No Gap in Corner

WRONG CORRECT

Window Jamb

Sill

DuPont™FlexWrap™ RW

B

C

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 93

DuPont™ Flashing Systems Installation Guidelines

STEP 4A. Remove release paper fi rst from either side 3 or side 4 – but not both.

NOTE: Keeping the remaining release papers intact will keep the DuPont™ FlexWrap™ RW more rigid and help to maneuver the fl ashing into the corners.

B. Place prepared DuPont™ FlexWrap™ RW tightly into corner of outer sill. Once in place, lift exposed butyl and adhere to window jamb.

C. Lift the remaining side and remove second piece of release paper exposing butyl. Fold down and attach butyl to sill.

Page 94: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

1

2

A

B

C

D

E

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 94

DuPont™ Flashing Systems Installation Guidelines

STEP 5A. Fold fl aps 1 and 2 and remove both pieces of release paper. Adhere butyl to inner recessed sill plate.

B. Fan out outer corners of the DuPont™ FlexWrap™ RW and tack corners on to the face of the wall in three places using recommended fasteners.

C. Place a bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant inside the corner fl ap behind the loose triangular fl ap of the corner piece.

D. Press down the loose triangular fl ap onto sealant in the corner piece.

E. Staple down fl ap.

Page 95: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

CB

A

D

S

FRONT VIEW CORNER DETAIL

No Gap in Corner

WRONG CORRECT

Window Jamb

DuPont™

FlexWrap™ NF

Sill

X

6” Minimum

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 95

DuPont™ Flashing Systems Installation Guidelines

STEP 6A. Using 9” width DuPont™ StraightFlash™, cut the length of the fl ashing slightly

SHORTER than the length of the outer sill (S).

B. Break all the perforations on the release paper by folding the fl ashing. If some perforations do not break, apply pressure with fi ngers to the area on the opposite side to break the remaining perforations.

NOTE: Failure to break all perforations will result in tearing of the release paper during its removal thereby making the installation diffi cult.

C. Fold in, remove center release paper and adhere to sill.

D. Unfold remaining DuPont™ StraightFlash™, remove remaining pieces of release paper and adhere butyl adhesive side to face of recessed sill and to face of the DuPont™ Tyvek® WRB.

STEP 7A. Cut DuPont™ FlexWrap™ NF at least 12” LONGER than width of inner/recessed sill

(X).

B. Remove fi rst piece of release paper. Cover horizontal sill by aligning inside edge of sill, and adhere into rough opening along sill and up jambs (min. 6” on each side).

C. Remove second release paper.

D. Fan out DuPont™ FlexWrap™ NF at bottom corners onto the face of the wall. Coverage of DuPont™ FlexWrap™ NF should be 2” to 3” onto the face of the framing.

Page 96: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

A

B

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 96

DuPont™ Flashing Systems Installation Guidelines

STEP 8A. Apply DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant on three sides (jambs and head) as

shown below. If sealant is applied to the sill, ensure that there are at least two (2) 2” gaps in the sealant bead for every 4’ of window to allow for drainage.

B. Install window per manufacturer’s instruction.

Page 97: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

X

B

C

A

B

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 97

DuPont™ Flashing Systems Installation Guidelines

STEP 9A. Fold 9” DuPont™ StraightFlash™ to break all of the perforations on the release paper.

If some perforations do not break, apply pressure with fi ngers to the area on the opposite side to break the remaining perforations.

NOTE: Failure to break all perforations will result in tearing of the release paper during its removal making the installation diffi cult.

B. Fold DuPont™ StraightFlash™ into three sections and remove only the center release paper. Place exposed butyl adhesive side onto the jamb.

NOTE: Keeping the remaining release papers intact will keep the DuPont™ FlexWrap™ RW more rigid and help to maneuver the fl ashing into the corners.

C. Once the butyl is adhered to the rough opening of the jamb, the two remaining release papers can be removed and the fl ashing can be attached to the window fl ange and onto the face of the exterior sheathing.

D. Repeat on opposite jamb.

STEP 10A. Install DuPont™ FlexWrap™ RW on the upper corner of the window rough opening onto

the window fl anges in a similar manner used on lower corner pieces. (see Step 4)

B. Fan out outer corners of the DuPont™ FlexWrap™ RW and tack corners onto the face of the wall in three places using recommended fasteners.

Page 98: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

B

A

C

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 98

DuPont™ Flashing Systems Installation Guidelines

STEP 11A. Place a bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant on underside

behind corner fl ap of loose triangular fl ap in corner.

B. Press down loose triangle fl aps onto the sealant in the corner piece.

C. Staple down fl ap after applying the sealant behind fl ap.

Page 99: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Y

Interior

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 99

DuPont™ Flashing Systems Installation Guidelines

STEP 12A. Cut a piece of 9” width DuPont™ StraightFlash™ one inch (1”) SHORTER than

distance of “Y“.

B. Break perforation lines as described in jamb and sill instructions. (see Step 9)

C. Remove the outer pieces of release paper.

D. Place on window fl ange.

E. Remove inner piece of release paper and adhere to the head.

F. Remove last and outer piece of release paper and adhere to exterior sheathing.

STEP 13Install DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use DuPont™ Window & Door Foam or recommended foam. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. DuPont™ Residential Sealant or DuPont™ Commercial Sealant should be tooled fl at to allow the natural curing process to create a concave shape. Be sure that the sealant penetrates the grooves of the DuPont™ FlexWrap™ NF around the sill.

NOTE: Installations that specify a window/door design rating of DP45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating.

Page 100: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 100

DuPont™ Flashing Systems Installation Guidelines

STEP 14After installing the DuPont™ Tyvek® WRB, cut as shown to expose window and apron. (Refer to the DuPont™ Tyvek® Water-Resistive Barriers Installation Guidelines to install the DuPont™ Tyvek® WRB properly).

DO NOT CUT THROUGH DUPONT™ FLASHING SYSTEMS PRODUCTS OR APRON

STEP 15Final Step

A. Tape seams as shown. DO NOT TAPE at bottom of window. At the head, continuous tape seams as shown with DuPont™ Tyvek® Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired.

B. Lap bottom of apron and the DuPont™ Tyvek® WRB over building materials below for proper shingling.

Page 101: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 101

DuPont™ Flashing Systems Installation Guidelines

ALTERNATE TAPE DETAIL

Place a continuous bead of DuPont™ Residential Sealant, DuPont™ Commercial Sealant, or recommended sealant around the jamb and head fl ashing under the DuPont™ Tyvek® WRB. Press the DuPont™ Tyvek® WRB securely into the sealant.

Page 102: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 102

DuPont™ Flashing Systems Installation Guidelines

Key Installation Requirements for Drainable Window/Door Installation Under the Product and Labor WarrantyWhen fl ashing windows or doors, the following principles must be followed:

• DuPont™ StraightFlash™, DuPont™ StraightFlash™ VF, DuPont™ Flashing Tape and DuPont™ FlexWrap™ NF self-adhered fl ashing meet the requirements of AAMA 711. Use proper installation to ensure nail sealability around the entire perimeter of the window/door and to protect critical window/door-wall interfaces. Metal sill pan fl ashing may be used, but must not replace fl exible sill fl ashing.

• Ensure that sill fl ashing does not slope to the interior. An exterior slope is recommended, but not required.

• Direct water onto an acceptable weather barrier drainage plane with an unobstructed path (or to the exterior of the wall using through wall fl ashing). Provide a drainage path for any water intrusion through the window/door attachment system that collects at the sill.

• Properly integrate fl ashing with acceptable DuPont™ Tyvek® water-resistive barrier in accordance with the instructional drawing. Self-adhered fl ashing must be applied with a minimum 2” lap onto the weather barrier.

• Review the sealant manufacturer’s literature or sealant label that the sealants used have the chemical and adhesive properties necessary for use with DuPont™ Flashing Systems products.

• Ensure that DuPont™ Flashing Systems products are installed in temperatures above 25°F (-4°C). Ensure the sealant materials meet the installation temperature requirements of the sealant manufacturer.

• Properly prepare all surfaces (remove dirt, dust, or moisture, etc.) per manufacturer’s recommendations.

• Use primer for loosely bonded surfaces (i.e., fi berboard) or cold installations per manufacturer’s recommendations.

• Barrier installations (full perimeter seal on exterior) are acceptable only in the following instances:

– Slab on grade doors, store front windows, or other systems with built in drainage mechanisms that have potential for exposure to standing water

– Surface barrier wall systems with non-water sensitive framing material (i.e., CMU walls)

– Very low wind/rain exposure regions (southwest/desert) that follow AAMA 2400 installation standard

• Ensure that window/door and fl ashing system design takes into account common factors that will impact performance:

– Climate considerations: Rainfall, Wind, Temperature (hot/cold cycles), Humidity

– Building design: Window/Wall Design (overhangs, recessed openings, bump-outs), Wall Assembly (wood frame or masonry), Window System (wood or vinyl), New Construction or Replacement Window drainage path

– Other considerations: UV exposure prior to the construction of the exterior facade, Flammability

• Field testing the window/door and wall installation as a complete system is a recommended best practice.

• Use of trained installers is highly recommended.

Page 103: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

INCORRECTDuPont™

FlexWrap™ NF reverse flashed

INCORRECTDuPont™ StraightFlash™

flush with DuPont™ FlexWrap™ NF

CORRECTDuPont™ StraightFlash™

overlaps DuPont™ FlexWrap™ NF

Copyright ©2011 E. I. du Pont de Nemours and Company. All Rights Reserved. Rev. 10/11 103

DuPont™ Flashing Systems Installation Guidelines

Proper overlap for water management NOTE: A condition of the DuPont 10 year Limited Warranty is compliance with the Installation Guidelines for DuPont Weatherization Products. In the event that a specifi c detail or installation technique is not part of the Installation Guidelines at the time that you are building, then the Key Installation Principles outlined in this document should be followed. Please contact DuPont with any questions regarding these Installation Guidelines.

Page 104: DuPont Flashing Systems Installation · PDF fileDuPont™ Flashing Systems Installation Guidelines ... DuPont™ Flashing Systems Installation Guidelines ... or for installations that

Copyright © 2011 E. I. du Pont de Nemours and Company. All rights reserved. The DuPont Oval Logo, DuPont™, Tyvek®, FlexWrap™, and StraightFlash™ are registered trademarks or trademarks of DuPont or its affiliates. All rights reserved. K-17933 10/11

Technical Specifi cationsDuPont™ Tyvek® WRBs used in construction products are made from 100% fl ash spunbonded high density polyethylene fi bers which have been bonded together by heat and pressure, without binders or fi llers, into a tough, durable sheet structure. Additives have been incorporated into the polyethylene to provide ultraviolet light resistance. DuPont requires that DuPont™ Tyvek® CommercialWrap® and CommercialWrap® D be covered within 9 months (270 days) of installation and that all other DuPont™ Tyvek® WRB’s be covered within 4 months (120 days) of installation.

DuPont™ Flashing Systems products are made from a synthetic rubber adhesive and a laminate of polyethylene fi lm, polypropelene fi lm, elastic fi ber, synthetic rubber adhesive, polyurethane adhesive, and a top sheet of fl ash spunbonded high density polyethylene fi bers or polypropelene fi lm. Additives have been incorporated into these materials to provide ultraviolet light resistance. DuPont requires that DuPont™ Flashing Systems products be covered within four months (120 days) of installation.

WarningDuPont™ Tyvek® Water-Resistive Barriers are slippery and should not be used in any

application where it will be walked on. In addition, because they are slippery, DuPont

recommends using kickjacks or scaffolding for exterior work above the fi rst fl oor. If ladders

must be used, extra caution must be taken to use them safely by following the requirements

set forth in ANSI Standards 14.1, 14.2 and 14.5 for ladders made of wood, aluminum, and

fi berglass, respectively. DuPont™ Tyvek® products are combustible and should be protected

from a fl ame and other high heat sources. DuPont™ Tyvek® products will melt at 275°F (135°C);

if the temperature of DuPont™ Tyvek® products reaches 750°F (400°C), it will burn and the fi re

may spread and fall away from the point of ignition. For more information, call

1-800-44-Tyvek.

DuPont™ Flashing Systems products and their release paper are slippery and should not be

walked on. Remove release paper from work area immediately. DuPont™ Flashing Systems

products will melt at temperatures greater than 250°F (121°C). DuPont™ Flashing Systems

products are combustible and should be protected from fl ames and other high heat sources.

DuPont™ Flashing Systems products will not support combustion if the heat source is

removed. However, if burning occurs, ignited droplets may fall away from the point of

ignition. For more information, call 1-800-44-Tyvek.

DuPont™ Residential Sealant and DuPont™ Commercial Sealant are irritating to skin, eyes, and

respiratory tract. For proper usage, follow directions stated on the product label. For health

information, refer to the Material Safety Data Sheet or call Chemtrec at 1-800-424-9300.

NoteWhen installed in conjunction with other building materials, DuPont™ Flashing Systems products must be properly shingled with these materials such that water is diverted to the exterior of the wall system. DuPont™ Tyvek® products are air and water barriers and not the primary water barrier. The outer facade is the primary barrier. You must follow facade manufacturer’s installation and maintenance requirements for all facade systems in order to maintain water holdout properties and ensure performance of DuPont™ Tyvek® products. Use of additives, coatings or cleansers on or in the facade system may impact the performance of DuPont™ Tyvek® water-resistive barriers. DuPont™ Tyvek® Weatherization Systems products are to be used as outlined in this installation guideline. DuPont™ Flashing Systems products should only be used to seal penetrations and fl ash openings in houses or buildings. DuPont™ Flashing Systems products are not to be used in roofi ng applications. For superior protection against bulk water penetration, DuPont suggests a system combining a quality exterior facade, a good secondary weather barrier and exterior sheathing, high quality windows and doors, and appropriate fl ashing materials paying attention to proper installation of each component. In a system where no exterior sheathing is used and DuPont™ Tyvek® WRB is installed directly over the wall studs, exterior facade materials should be selected to ensure maximum protection against water intrusion. Careful workmanship and proper installation of each component is very important.

DuPont believes this information to be reliable and accurate. This information may be subject to revision as additional experience and knowledge is gained. It is the user’s responsibility to determine the proper construction materials needed on each project.

For complete warranty information, please visit www.Weatherization.Tyvek.com or call 1-800-44-Tyvek.

This information is not intended to be used by others for advertising, promotion or other publication for commercial purposes.

For more information about DuPont Weatherization Systems, please call 1-800-44-Tyvek or visit us at www.weatherization.tyvek.com