dvm catalog

62
Samsung Electronics Co., LTD. Head Office (Suwon Korea) 416, Maetan-3Dong, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea 443-742 www.dvmsystem.com / Tel : 82-31-200-6421 / Fax : 82-31-200-0938 Ver.4 imagine refreshing comforts 2008 Samsung DVM System Air Conditioner will provide you refreshing coolness. Feel the comfort you have never experienced with the cool, refreshing air that Samsung’s new DVM PLUS Air Conditioners provides. Experience the maximum comfort in real life. With Samsung, imagination comes to life. 2008 SAMSUNG SYSTEM AIR CONDITIONERS Ver.4

Upload: lee-viet-nguyen

Post on 24-Jul-2015

166 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: DVM Catalog

Samsung Electronics Co., LTD.Head Office (Suwon Korea) 416, Maetan-3Dong, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea 443-742www.dvmsystem.com / Tel : 82-31-200-6421 / Fax : 82-31-200-0938 Ver.4

imagine refreshing comforts2008 Samsung DVM System Air Conditioner will provide you

refreshing coolness. Feel the comfort you have never experienced

with the cool, refreshing air that Samsung’s new DVM PLUS Air

Conditioners provides. Experience the maximum comfort in real

life. With Samsung, imagination comes to life.

2008 SA

MS

UN

G

SY

STE

M A

IR C

ON

DITIO

NE

RS

Ver.4

Page 2: DVM Catalog

In the Digital era, products are being distinguished by their brand in addition to their functions or quality.

In 1999 Samsung Electronics has implemented its global brand communication strategy. Since then,

based on the research conducted by Interbrand INC., USA, Samsung Electronics has become one of the

fastest growing brands equities from 6.4 billion USD (2001) to over 16.85 billion USD (2007) and is now

ranked 21st on Interbrand's Top100 Global Brand List.

Samsung has increased its value by emphasizing technology as a life innovator. Samsung will remain

close to the customer through its technologies contributing to a higher quality of life.

SAMSUNG brand equity has reached 16.85 billion USD in 2007

Tremendous Investment in R & DSamsung's thrust on Product Innovation and R&D has given the company a competitive edge in the marketplace.

With an investment of over USD 4.59 billion, Samsung operates 16 R&D centers worldwide and employs

27,000 researchers of which 2,500 hold a Ph. D. As a result, Samsung has already applied for 1600 patents in

the USA. The focus of the R&D center is to customize electronics products to meet the Specific needs of

consumers in that region. Samsung R&D Centers are helping the company to continuously innovate and

introduce products customized for today’s global market.

LondonMoscow

Israel

Bangalore

Beijing

NanjingSuzhou

Giheung(3)

Yokohama

Suwon(3)San Jose

Dallas

The Best Global Brands 2007 Report Ranking by Interbrand

What is “Green Management?”SAMSUNG Electronics' corporate policy of making "Green Management, the

top priority of all corporate activities" has led to bold and continuous

measures. Such measures include developing green technologies and green

products, reducing waste and maintaining accident-free workplaces based

on the five pillars of Green Management: Management, Products, Processes,

Workplaces and Communities. SAMSUNG is not only making its products

more environmentally friendly, but is also building pollution-free workplaces by

minimizing the use of harmful substances in processes and developing

greener substitutes. With the pursuit of green management, Samsung will

continue to create new values as a digital leader in the 21st century.

SAMSUNG

Big ConfidenceGlobal LeadingCompany >>

Page 3: DVM Catalog

02_ Brand Value

06_ Line-up

10_ New Technology

18_ DVM PLUS / HR

42_ Mini DVM

46_ Free Joint Multi

108_ Integrated Management System

116_ Centralized Control System

118_ Individual Control System

120_ Building Management System

123_ Accessories

Introduction

Indoor Units

Outdoor Units

Control Systems62_ Wall mounted Type

70_ Cassette Type

84_ Duct Type

92_ Floor & Convertible Type

100_ ERV System

104_ Accessories

2008 Samsung DVM System Air Conditioners have all the desirable features you can possibly get. This year’s

outdoor units with new advanced technologies are more powerful and efficient. Stylish indoor units have also

become more compact for easier installation. Complete control system helps easier control and adds

convenience. Everything is just ahead of your expectation for absolute satisfaction.

imaginebeyond your limit

2 0 0 8 S a m s u n g D V M A i r C o n d i t i o n e r s

Page 4: DVM Catalog

Line-up - Outdoor Units Samsung DVM Air Conditioners runs with new refrigerant R410A, which will not pollute our global environment.

DVM PLUS III / DVM PLUS III HR

Free Joint Multi

4.0kW

2 Units

5.0kW

2 Units

6.0kW

3 Units

7.0kW

4 Units

8.0kW

4 Units

Mini DVM

4HP 5HP 6HPBasic Model

Combination Table

High Efficiency Combination

Compact Combination

Line up

High Efficiency Combination

RVXVHT080GERVXVRT080GE

8HP 10HP 12HP 14HP

8HP 10HP 12HP 14HP 16HP

DVM PLUS IIIDVM PLUS III HR

RVXVHT100GERVXVRT100GE

RVXVHT120GERVXVRT120GE

Line up

Compact Combination

Model 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56

RVXVHT080GERVXVRT080GE

RVXVHT100GERVXVRT100GE

RVXVHT120GERVXVRT120GE

RVXVHT140GERVXVRT140GE

Model 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58

RVXVHT080GERVXVRT080GE

RVXVHT100GERVXVRT100GE

RVXVHT120GERVXVRT120GE

60 62 64

RVXVHT140GERVXVRT140GE

RVXVHT160GERVXVRT160GE

06 07

RVXVHT140GERVXVRT140GE

RVXVHT080GERVXVRT080GE

RVXVHT100GERVXVRT100GE

RVXVHT120GERVXVRT120GE

RVXVHT140GERVXVRT140GE

RVXVHT160GERVXVRT160GE

DVM PLUS IIIDVM PLUS III HR

2 1

1 2 1

1

3 2

1

1

2 3 2

1

2

1

1

1

1

1

2

1

2 3

3

1

2

1

1

2

2

1

1

2

2

2

1

3 4

1

1 2 1

1

1

1

1

1 2 1

1 2

1

2 3 2

1

2

1

1

1

1

2

1

1

2 3

3

1

3

1

1

1

2

1

1

2

1

3

1

3

1

3 4

Page 5: DVM Catalog

Line-up - Indoor Units

Samsung DVM Air Conditioners runs with new refrigerant R410A, which will not pollute our global environment.

Type

Slim 1Way

7K Btu/h

2.2 kW

9K Btu/h

2.8 kW

12K Btu/h

3.6 kW

15K Btu/h

4.5 kW

18K Btu/h

5.6 kW

21K Btu/h

6.0 kW

24K Btu/h

7.1 kW

30K Btu/h

9.0 kW

36K Btu/h

11.2 kW

44K Btu/h

12.8 kW

4Way cassette

Mini 4Way cassette

2Way cassette

Slim Duct

M.S.P Duct

MB

Vivace

Neo Forte

Console

Ceiling

48K Btu/h

14.0 kW

KBtu/hkW

08 09

Page 6: DVM Catalog

See this year’s new technologies with your own eyes. Never ending development ofSamsung’s technologies will satisfy all your expectations. Each of this year’s new technologieswere considered to provide you the most efficient and convenient air conditioners. Experienceall the newest technologies. Feel the difference.

New Technology

imaginenever ending development

10 11

New Technology

New

Technology

Page 7: DVM Catalog

New Technology

2008 SAMSUNG DVM Air Conditioners New Technology

12 13

DVI CompressorEfficient and reliable DVI Compressor coupled with VaporInjection technology has been applied to improve coolingand heating performance and energy efficiency.

DHS (Digital Hybrid System) is a brand new concept system composed of DVI compressor, vapor injectiontechnology and turbo intercooler. These 3 factors together provide highly efficient performance.

Highly efficient O8 Grooved tube hasbeen applied to reduce pressureloss while increasing heat transferperformance to improve COP.

High efficiency new G-fin improved heattransfer performance and reinforce corrosion resistance.

Turbo intercooler(Shell and Tube Type)improves cooling and heating COP andsecure reliability on long piping installation.

DVI (Digital Vapor Injection) compressorinjects optimized mid-range pressurerefrigerant to improve cooling and heatingperformance and efficiency.

Fan Guard

Ø8 Heat Exchanger

O8 Heat Exchanger

Newly Designed G-Fin

New G-Fin

Turbo Intercooler

Vapor Injection Compressor

Turbo Intercooler

DVI Compressor

OverviewNew DVM Plus III System Air Conditioner has improved its performance with remarkabletechnologies. We now introduce these notable technologies and how they improved the performance of your air conditioner. Witness the wonderful technologies that makes better world.

Turbo IntercoolerTurbo intercooler (Shell & Tube Type) improved cooling andheating COP, to secure reliability on long piping installation.● Improve COP with the application of Turbo intercooler.

● Adequate sub-cooling to ensure reliable operation on installationswith long piping (200 m).

Subcooled liquid refrigerant

Low temperature gasrefrigerant

Vapor Injection Tube

Vapor Injection Port

Low temp. liquid refrigerant

Saturated liquid refrigerant

New Technology

Digital Hybrid System

DVICompressor

VaporInjection Turbo

Intercooler

Vapor Injection TechnologyImproved cooling and heating performance and COP by anew technology of two stage compression. This technologyachieved the high heating performance and COP underthe lowest temperature, which leads the industry.● Increase refrigerant flow rates with a new Vapor Injection

technology.

● Improved Sub-cooling necessary for long piping runs whileincreasing cooling and heating performance and COP.

Temperature

High

Low

❶ ❶

Optimized fan guard design enhancedair flow volume which achieved the highheat transfer performance withoutincreased noise.

Fan Guard

New

Technology

Page 8: DVM Catalog

New Technology

2008 SAMSUNG DVM Air Conditioners New Technology

14 15

Newly Designed Fan GuardFan Guard has been optimized to improve air volume and reduce noise and vibration.

● BLDC Motor, which is 2.7% more efficient than the competitors, has been applied.

● Applied high static pressure propeller fan and the optimum Bell Mouth form for high external static pressure. (External static pressure: 8mmAq)

New G- FinHighly efficiency new G-Fin increased heat transfer performance, reinforced corrosion resistance, and increasedoperating duration in frost condition.● Heat transfer performance improved by 13% compared to the conventional fin, even with the equivalent pressure loss.

● Epoxy Acrylic Coating reinforced corrosion resistance.

● Heating operation time is 1.4 times longer in frost condition due to new G-Fin.

Hydrophilic layer Acrylic resin + surfactantAnti corrosive layer

Epoxy acrylic

Raw aluminummaterial

0.3µm

2.0µm

92µm

Conventional (Louver Fin)DVM PLUS III (New G-Fin)

Wide Louver FinG - Fin

Cap

acity

, Pow

er o

utpu

t (W

) 5000

4000

3000

2000

1000

00 30

Time (min.)60 90 120

EVA

. CO

ND

tem

pera

ture

(°C) 60

50

40

30

20

10

0

-10

-20

-300 30

Time (min.)60

DVM PLUS III

Conventional Model

New Technology

High Efficiency O8 Heat ExchangerEfficient O8 Grooved tube reduced pressure loss while increasing heat exchange rates to improve COP.

● Groove shape is designed to be high and slim to increase heat transfer performance inside the tube.

DVM PLUS IIINew Groove Shape (High and Slim)

Competitor’s Product

Item Improved Heat ExchangerO7 ➝ O8

19% ↑14.1% ↓10.3% ↓30.8% ↑

same

DiameterHeat transfer surface areaPressure loss in heatexchangerInternal heat transfer performancePressure resistance

EvaporationCondensation

O8 Heat Exchanger and New G-fin

New

Technology

Page 9: DVM Catalog

New DVM Plus III system air conditioners have become more powerful, efficient and compact.DVM Plus III is equipped with more advanced technologies to provide effective cooling andheating, save energy, and help easier installation. DVM Plus III has capacity up to 64HP withmore compact size. Be ready for the new generation of the outdoor unit.

Outdoor Units

>> 18_ DVM PLUS III / HR >> 42_ Mini DVM >> 46_ Free Joint Multi

imaginethe absolute power

Outdoor Units

16 17

Outdoor U

nits

Page 10: DVM Catalog

Outdoor Units - DVM PLUS III / HR

2008 SAMSUNG DVM Air Conditioners Outdoor Units

18 19

Outdoor U

nits

DVM PLUS III / HR Multi Modular Technology

Comparison to Inverter IIIDVM PLUS IIIDVM PLUS III

Company ACompany A

Up to 56HP

Only 36HP

DVM PLUS IIIDVM PLUS III

Company ACompany A

Up to 64HP

Only 54HP

HighEfficiency

Combinations

Compact Combinations

Line up

DVM Plus III/HR offers the largest capacity in the industry with 64HP andboasts the highest COP levels. More compact size, with larger capacity,shows the efficiency of the product. DVM Plus III HR has all the featureswhich DVM Plus III has and offers even more features. DVM Plus III HR willgive you simultaneous cooling and heating where different air conditioning isneeded under same outdoor unit.

Basic Model

Line up

High Efficiency Combinations

RVXVHT080GERVXVRT080GE

8HP 10HP 12HP 14HP

8HP 10HP 12HP 14HP 16HP

DVM PLUS IIIDVM PLUS III HR

RVXVHT100GERVXVRT100GE

RVXVHT120GERVXVRT120GE

Line up

Compact Combinations

RVXVHT140GERVXVRT140GE

RVXVHT080GERVXVRT080GE

RVXVHT100GERVXVRT100GE

RVXVHT120GERVXVRT120GE

RVXVHT140GERVXVRT140GE

RVXVHT160GERVXVRT160GE

DVM PLUS IIIDVM PLUS III HR

Combination Table

High Efficiency Combinations

Compact Combinations

Model 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56

RVXVHT080GERVXVRT080GE

RVXVHT100GERVXVRT100GE

RVXVHT120GERVXVRT120GE

RVXVHT140GERVXVRT140GE

Model 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58

RVXVHT080GERVXVRT080GE

RVXVHT100GERVXVRT100GE

RVXVHT120GERVXVRT120GE

60 62 64

RVXVHT140GERVXVRT140GE

RVXVHT160GERVXVRT160GE

2 1

1 2 1

1

3 2

1

1

2 3 2

1

2

1

1

1

1

1

2

1

2 3

3

1

2

1

1

2

2

1

1

2

2

2

1

3 4

1

1 2 1

1

1

1

1

1 2 1

1 2

1

2 3 2

1

2

1

1

1

1

2

1

1

2 3

3

1

3

1

1

1

2

1

1

2

1

3

1

3

1

3 4

Page 11: DVM Catalog

Outdoor Units - DVM PLUS III / HR

2008 SAMSUNG DVM Air Conditioners Outdoor Units

20 21

Outdoor U

nits

High COPHigh efficiency DVM PLUS III has improved average cooling and heatingCOP compared to conventional products and achieved the world’s TopClass energy efficiency

● DHS(Digital Hybrid System) technology increased refrigerant flow rate andevaporation enthalpy difference.

● Wide O8 Grooved pipe and G-Fin increased heat exchange efficiency.

● The best BLDC Motor in the industry and Optimum Fan Guard designincreased efficiency.

ConventionalConventional

DVM PLUS IIIDVM PLUS III

Company ACompany A

Company ACompany A

3.81 11%

10%

4.23

4.15

ConventionalConventional

DVM PLUS IIIDVM PLUS III

3.73

4.10

4.02

8HP

18HP

Model 12HP 16HPConventional Model 0.92m2 1.35m2

DVM PLUS III 0.67m2 0.92m2

Comparison to Conventional Model 73% 68%

16HP

Approx. 32%reduction

1.35m2 0.92m2

Conventional Model DVM PLUS III

ConventionalModel

DVMPLUS III

8HP 10HP 12HP 14HP 16HP

27% reduction32% reduction

The Smallest Foot Print AreaThe world’s smallest foot print provides smallest installatoinspace which saves incredible amount of time.

Space Saving

8~48HP 8~64HP

Conventional Model DVM PLUS III

The World’s Largest CapacitySamsung has achieved world’s largest capacity of 64HP by combining maximum 4 outdoor units with 5 different capacities. (8, 10, 12, 14 and 16HP) Many combinations of Heat Pump or Heat Recovery types supporting up to 64 indoor units provide consumers variety of choices for any installation condition.

● Compact combinations (8~64 HP) : Combination with the model requiring the smallest installation space.

● High-Efficiency combinations (16~56 HP) : Combination with high-efficiency model.

Digital Unit ModuleDigital Unit Module combination enables the system to alternatecompressor operation to prolong each compressor’s life cycleand improves COP with part loads

● Control the compressor capacity precisely.

● Ensure long life cycle by alternating operation of the DVI compressors.

● Improve COP using multiple heat exchangers of outdoor units at partloads.

DVIScroll

FVIScroll

DVIScroll

FVIScroll

A unit B unit

The World’s Longest Piping Length

The longest pipinglength : 220m(Equivalent Length)

Height differencesbetween indoor &

outdoor units : 50m

The first branch joint to the farthest indoor unit : 45 m(1 Size Up : 90 m)Height difference between indoor units : 15m

DVM PLUS III has an actual piping length up to 200m, with the maximum piping length of 45m from the first branchjoint to farthest indoor unit, thereby providing more convenience and flexibility for installation in commercial buildings.

Summary● The longest piping length : 220m (Equivalent Length)

● Total piping length: 1000 m

● From the first branch joint to the farthest indoor unit : 90m (with one piping Size Up)

Page 12: DVM Catalog

Outdoor Units - DVM PLUS III / HR

2008 SAMSUNG DVM Air Conditioners Outdoor Units

22 23

Free InstallationDVM Plus III/HR provides the degree of freedom from priority of capacity when installing outdoor units in module.

DVM PLUS III

No limits.

8HP(Digital Unit)

14HP(Digital Unit)

10HP(Digital Unit)

Conventional model

A digital outdoor unit with the largestcapacity should come last.

8HP(Fixed Unit)

10HP(Fixed Unit)

14HP(Digital Unit)

Outdoor U

nits

External Static PressureTo respond to a range of various installation environments, DVM PLUS III isdesigned to be used even in external static pressure of 8 mm Aq.

Automatic Piping Length RecognitionAuto piping length recognition system saves time with no additional settings and performs the optimum operation inaccordance with piping length.

Lead-Free and RoHs

Refrigerant Leakage PreventionTo prevent refrigerant leakage, we provide how to diagnose any refrigerant leakage in operation. Also, changing service valves from flange type to brazedtype further prevents refrigerant leakage.

RoHs ComplianceAlthough RoHS restriction only applies to small and large household electronics, IT equipment, lightings, power train, toys, leisure and sportsequipment, and vending machines. Samsung expands the RoHS restrictioninto its entire range of products based on its own environmental policies.

Lead-FreeDVM Plus III is an eco-friendly product that prevents pollutionproblems caused by the use of lead, by applying lead-freeindoor and outdoor PCBs.

Heating

HeatingCooling

Cooling

Heating

Cooling

MCU(Mode Change Unit)

As DVM PLUS III HR allows a simultaneous cooling and heatingoperation with one system, there are variety range of application.

● Great for places where simultaneous cooling and heating operation isrequired. (Hotels, nursing homes, conference rooms, etc.)

● For seasonal air-conditioning which may need a simultaneous coolingand heating operation.

● In case of medium and large office, DVM PLUS III HR satisfies cooling and heating operation simultaneously for the requirements ofinterior and perimeter zone.

DVM PLUS III HR Versatile Application

Company A

An outdoor unit with the largest capacityshould come first.

14HP 10HP 8HP

Optimal operation by automatic piping length recognition

Off OffOn On

L

On

> >

Page 13: DVM Catalog

Outdoor Units - DVM PLUS III / HR

2008 SAMSUNG DVM Air Conditioners Outdoor Units

24 25

Outdoor U

nits

Specification | DVM PLUS III / HR

Basic Model

Model

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

DVM PLUS III DVM PLUS III HR

RVXVHT080GERVXVRT080GE

RVXVHT100GERVXVRT100GE

RVXVHT120GERVXVRT120GE

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

3/380~415/50

HP/HR

8

22.4

76,400

25.2

86,000

5.76

5.51

25

3.89

4.57

Propeller/BLDC

9.52

19.05

15.88

-

200

50 (40)

R410A

7.5

57

240

242

253

255

880x1,703x765

948x1,868x832

-5~43

-20~24

3/380~415/50

HP/HR

10

28.0

95,500

31.5

107,500

7.78

7.16

30

3.60

4.40

Propeller/BLDC

9.52

22.23

19.05

-

200

50 (40)

R410A

7.5

58

240

242

253

255

880x1,703x765

948x1,868x832

-5~43

-20~24

3/380~415/50

HP/HR

12

33.6

114,600

37.8

129,000

10.40

9.40

40

3.23

4.02

Propeller/BLDC

12.70

25.40

22.23

-

200

50 (40)

R410A

7.5

60

240

242

253

255

880x1,703x765

948x1,868x832

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.- Specifications are subject to change without prior notice for product improvement.

Model

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

DVM PLUS III DVM PLUS III HR

RVXVHT140GERVXVRT140GE

RVXVHT160GERVXVRT160GE

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

3/380~415/50

HP/HR

14

39.2

133,800

44.1

150,500

11.00

10.40

40

3.56

4.24

Propeller/BLDC

12.70

25.40

22.23

-

200

50 (40)

R410A

11.0

60

320

323

337

340

1,200x1,703x765

1,268x1,868x832

-5~43

-20~24

3/380~415/50

HP/HR

16

44.8

152,900

50.4

172,000

14.80

15.00

50

3.03

3.36

Propeller/BLDC

12.70

28.58

22.23

-

200

50 (40)

R410A

11.0

60

320

323

337

340

1,200x1,703x765

1,268x1,868x832

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.- Specifications are subject to change without prior notice for product improvement.

Page 14: DVM Catalog

Outdoor Units - DVM PLUS III / HR

2008 SAMSUNG DVM Air Conditioners Outdoor Units

26 27

Outdoor U

nits

Specification | DVM PLUS III / HR

Model

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

16HP

Basic

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

RVXVRT080GE

RVXVRT100GE

RVXVRT120GE

RVXVRT140GE

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

RVXVHT080GE /

RVXVHT100GE /

RVXVHT120GE /

RVXVHT140GE /

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

2

3/380~415/50

HP/HR

16

44.8

152,800

50.4

172,000

11.52

11.02

50

3.89

4.57

Propeller/BLDC

12.70

28.58

22.23

6.35

200

50 (40)

R410A

7.5x2

60

240x2

242x2

253x2

255x2

(880x1,703x765)x2

(948x1,868x832)x2

-5~43

-20~24

18HP

1

1

3/380~415/50

HP/HR

18

50.4

171,900

56.7

193,500

13.54

12.67

50

3.72

4.48

Propeller/BLDC

15.88

28.58

25.40

6.35

200

50 (40)

R410A

7.5x2

60

240x2

242x2

253x2

255x2

(880x1,703x765)x2

(948x1,868x832)x2

-5~43

-20~24

20HP

2

3/380~415/50

HP/HR

20

56.0

191,000

63.0

215,000

15.56

14.32

60

3.60

4.40

Propeller/BLDC

15.88

28.58

25.40

6.35

200

50 (40)

R410A

7.5x2

61

240x2

242x2

253x2

255x2

(880x1,703x765)x2

(948x1,868x832)x2

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.- Specifications are subject to change without prior notice for product improvement.

Module Type - High EfficiencyModel

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

22 HP

Basic

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

RVXVRT080GE

RVXVRT100GE

RVXVRT120GE

RVXVRT140GE

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

RVXVHT080GE /

RVXVHT100GE /

RVXVHT120GE /

RVXVHT140GE /

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

1

1

3/380~415/50

HP/HR

22

61.6

210,100

69.3

236,500

18.18

16.56

60

3.39

4.18

Propeller/BLDC

15.88

28.58

25.40

6.35

200

50 (40)

R410A

7.5x2

62

240x2

242x2

253x2

255x2

(880x1,703x765)x2

(948x1,868x832)x2

-5~43

-20~24

24 HP

3

3/380~415/50

HP/HR

24

67.2

229,200

75.6

258,000

17.28

16.53

75

3.89

4.57

Propeller/BLDC

15.88

28.58

25.40

6.35

200

50 (40)

R410A

7.5x3

62

240x3

242x3

253x3

255x3

(880x1,703x765)x3

(948x1,868x832)x3

-5~43

-20~24

26 HP

2

1

3/380~415/50

HP/HR

26

72.8

248,300

81.9

279,500

19.30

18.18

75

3.77

4.50

Propeller/BLDC

19.05

31.75

28.58

6.35

200

50 (40)

R410A

7.5x3

63

240x3

242x3

253x3

255x3

(880x1,703x765)x3

(948x1,868x832)x3

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.- Specifications are subject to change without prior notice for product improvement.

Module Type - High Efficiency

Page 15: DVM Catalog

Outdoor Units - DVM PLUS III / HR

2008 SAMSUNG DVM Air Conditioners Outdoor Units

28 29

Outdoor U

nits

Specification | DVM PLUS III / HR

Model

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

28 HP

Basic

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

RVXVRT080GE

RVXVRT100GE

RVXVRT120GE

RVXVRT140GE

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

RVXVHT080GE /

RVXVHT100GE /

RVXVHT120GE /

RVXVHT140GE /

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

1

2

3/380~415/50

HP/HR

28

78.4

267,400

88.2

301,000

21.32

19.83

75

3.68

4.45

Propeller/BLDC

19.05

31.75

28.58

6.35

200

50 (40)

R410A

7.5x3

63

240x3

242x3

253x3

255x3

(880x1,703x765)x3

(948x1,868x832)x3

-5~43

-20~24

30 HP

3

3/380~415/50

HP/HR

30

84.0

286,500

94.5

322,500

23.34

21.48

100

3.60

4.40

Propeller/BLDC

19.05

31.75

28.58

6.35

200

50 (40)

R410A

7.5x3

63

240x3

242x3

253x3

255x3

(880x1,703x765)x3

(948x1,868x832)x3

-5~43

-20~24

32 HP

2

1

3/380~415/50

HP/HR

32

89.6

305,600

100.8

344,000

25.96

23.72

100

3.45

4.25

Propeller/BLDC

19.05

31.75

28.58

6.35

200

50 (40)

R410A

7.5x3

64

240x3

242x3

253x3

255x3

(880x1,703x765)x3

(948x1,868x832)x3

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.- Specifications are subject to change without prior notice for product improvement.

Module Type - High EfficiencyModel

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

34 HP

Basic

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

RVXVRT080GE

RVXVRT100GE

RVXVRT120GE

RVXVRT140GE

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

RVXVHT080GE /

RVXVHT100GE /

RVXVHT120GE /

RVXVHT140GE /

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

2

1

3/380~415/50

HP/HR

34

95.2

324,800

107.1

365,500

26.56

24.72

100

3.58

4.33

Propeller/BLDC

19.05

31.75

28.58

6.35

200

50 (40)

R410A

7.5x2+11x1

64

240x2+320x1

242x2+323x1

253x2+337x1

255x2+340x1

(880x1,703x765)x2+(1,200x1,703x765)x1

(948x1,868x832)x2+(1,268x1,868x832)x1

-5~43

-20~24

36 HP

1

1

1

3/380~415/50

HP/HR

36

100.8

343,900

113.4

387,000

29.18

26.96

100

3.45

4.21

Propeller/BLDC

19.05

38.10

31.75

6.35

200

50 (40)

R410A

7.5x2+11x1

64

240x2+320x1

242x2+323x1

253x2+337x1

255x2+340x1

(880x1,703x765)x2+(1,200x1,703x765)x1

(948x1,868x832)x2+(1,268x1,868x832)x1

-5~43

-20~24

38 HP

1

2

3/380~415/50

HP/HR

38

106.4

363,100

119.7

408,500

29.78

27.96

100

3.57

4.28

Propeller/BLDC

19.05

38.10

31.75

6.35

200

50 (40)

R410A

7.5x1+11x2

64

240x1+320x2

242x1+323x2

253x1+337x2

255x1+340x2

(880x1,703x765)x1+(1,200x1,703x765)x2

(948x1,868x832)x1+(1,268x1,868x832)x2

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.- Specifications are subject to change without prior notice for product improvement.

Module Type - High Efficiency

Page 16: DVM Catalog

Outdoor Units - DVM PLUS III / HR

2008 SAMSUNG DVM Air Conditioners Outdoor Units

30 31

Outdoor U

nits

Specification | DVM PLUS III / HR

Model

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

40 HP

Basic

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

RVXVRT080GE

RVXVRT100GE

RVXVRT120GE

RVXVRT140GE

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

RVXVHT080GE /

RVXVHT100GE /

RVXVHT120GE /

RVXVHT140GE /

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

1

2

3/380~415/50

HP/HR

40

112.0

382,200

126.0

430,000

32.40

30.20

125

3.46

4.17

Propeller/BLDC

19.05

38.10

31.75

6.35

200

50 (40)

R410A

7.5x1+11x2

65

240x1+320x2

242x1+323x2

253x1+337x2

255x1+340x2

(880x1,703x765)x1+(1,200x1,703x765)x2

(948x1,868x832)x1+(1,268x1,868x832)x2

-5~43

-20~24

42 HP

3

3/380~415/50

HP/HR

42

117.6

401,400

132.3

451,500

33.00

31.20

125

3.56

4.24

Propeller/BLDC

19.05

38.10

31.75

6.35

200

50 (40)

R410A

11x3

65

320x3

323x3

337x3

340x3

(1,200x1,703x765)x3

(1,268x1,868x832)x3

-5~43

-20~24

44 HP

3

1

3/380~415/50

HP/HR

44

123.2

420,300

138.6

473,000

34.34

31.88

125

3.59

4.35

Propeller/BLDC

19.05

38.10

31.75

6.35

200

50 (40)

R410A

7.5x3+11x1

65

240x3+320x1

242x3+323x1

253x3+337x1

255x3+340x1

(880x1,703x765)x3+(1,200x1,703x765)x1

(948x1,868x832)x3+(1,268x1,868x832)x1

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.- Specifications are subject to change without prior notice for product improvement.

Module Type - High EfficiencyModel

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

46 HP

Basic

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

RVXVRT080GE

RVXVRT100GE

RVXVRT120GE

RVXVRT140GE

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

RVXVHT080GE /

RVXVHT100GE /

RVXVHT120GE /

RVXVHT140GE /

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

2

1

1

3/380~415/50

HP/HR

46

128.8

439,400

144.9

494,500

36.96

34.12

125

3.48

4.25

Propeller/BLDC

19.05

38.10

31.75

6.35

200

50 (40)

R410A

7.5x3+11x1

65

240x3+320x1

242x3+323x1

253x3+337x1

255x3+340x1

(880x1,703x765)x3+(1,200x1,703x765)x1

(948x1,868x832)x3+(1,268x1,868x832)x1

-5~43

-20~24

48 HP

2

2

3/380~415/50

HP/HR

48

134.4

458,600

151.2

516,000

37.56

35.12

125

3.58

4.31

Propeller/BLDC

19.05

38.10

31.75

6.35

200

50 (40)

R410A

7.5x2+11x2

65

240x2+320x2

242x2+323x2

253x2+337x2

255x2+340x2

(880x1,703x765)x2+(1,200x1,703x765)x2

(948x1,868x832)x2+(1,268x1,868x832)x2

-5~43

-20~24

50 HP

1

1

2

3/380~415/50

HP/HR

50

140.0

477,700

157.5

537,500

40.18

37.36

150

3.48

4.22

Propeller/BLDC

22.23

44.50

38.10

6.35

200

50 (40)

R410A

7.5x2+11x2

66

240x2+320x2

242x2+323x2

253x2+337x2

255x2+340x2

(880x1,703x765)x2+(1,200x1,703x765)x2

(948x1,868x832)x2+(1,268x1,868x832)x2

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.- Specifications are subject to change without prior notice for product improvement.

Module Type - High Efficiency

Page 17: DVM Catalog

Outdoor Units - DVM PLUS III / HR

2008 SAMSUNG DVM Air Conditioners Outdoor Units

32 33

Outdoor U

nits

Specification | DVM PLUS III / HR

Model

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

52 HP

Basic

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

RVXVRT080GE

RVXVRT100GE

RVXVRT120GE

RVXVRT140GE

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

RVXVHT080GE /

RVXVHT100GE /

RVXVHT120GE /

RVXVHT140GE /

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

2

2

3/380~415/50

HP/HR

52

145.6

496,800

163.8

559,000

42.80

39.60

150

3.40

4.14

Propeller/BLDC

22.23

44.50

38.10

6.35

200

50 (40)

R410A

7.5x2+11x2

66

240x2+320x2

242x2+323x2

253x2+337x2

255x2+340x2

(880x1,703x765)x2+(1,200x1,703x765)x2

(948x1,868x832)x2+(1,268x1,868x832)x2

-5~43

-20~24

54 HP

1

3

3/380~415/50

HP/HR

54

151.2

516,000

170.1

580,500

43.40

40.60

150

3.48

4.19

Propeller/BLDC

22.23

44.50

38.10

6.35

200

50 (40)

R410A

7.5x1+11x3

66

240x1+320x3

242x1+323x3

253x1+337x3

255x1+340x3

(880x1,703x765)x1+(1,200x1,703x765)x3

(948x1,868x832)x1+(1,268x1,868x832)x3

-5~43

-20~24

56 HP

4

3/380~415/50

HP/HR

56

156.8

535,200

176.4

602,000

44.00

41.60

150

3.56

4.24

Propeller/BLDC

22.23

44.50

38.10

6.35

200

50 (40)

R410A

11x4

66

320x4

323x4

337x4

340x4

(1,200x1,703x765)x4

(1,268x1,868x832)x4

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.- Specifications are subject to change without prior notice for product improvement.

Module Type - High EfficiencyModel

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

18 HP

Basic

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

RVXVRT080GE

RVXVRT100GE

RVXVRT120GE

RVXVRT140GE

RVXVRT160GE

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

RVXVHT080GE /

RVXVHT100GE /

RVXVHT120GE /

RVXVHT140GE /

RVXVHT160GE /

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

1

1

3/380~415/50

HP/HR

18

50.4

171,900

56.7

193,500

13.54

12.67

50

3.72

4.48

Propeller/BLDC

15.88

28.58

25.40

6.35

200

50 (40)

R410A

7.5x2

60

240x2

242x2

253x2

255x2

(880x1,703x765)x2

(948x1,868x832)x2

-5~43

-20~24

20 HP

2

3/380~415/50

HP/HR

20

56.0

191,000

63.0

215,000

15.56

14.32

60

3.60

4.40

Propeller/BLDC

15.88

28.58

25.40

6.35

200

50 (40)

R410A

7.5x2

61

240x2

242x2

253x2

255x2

(880x1,703x765)x2

(948x1,868x832)x2

-5~43

-20~24

22 HP

1

1

3/380~415/50

HP/HR

22

61.6

210,100

69.3

236,500

18.18

16.56

60

3.39

4.18

Propeller/BLDC

15.88

28.58

25.40

6.35

200

50 (40)

R410A

7.5x2

62

240x2

242x2

253x2

255x2

(880x1,703x765)x2

(948x1,868x832)x2

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.- Specifications are subject to change without prior notice for product improvement.

Module Type - Compact

Page 18: DVM Catalog

Outdoor Units - DVM PLUS III / HR

2008 SAMSUNG DVM Air Conditioners Outdoor Units

34 35

Outdoor U

nits

Specification | DVM PLUS III / HR

Model

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

30 HP

Basic

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

RVXVRT080GE

RVXVRT100GE

RVXVRT120GE

RVXVRT140GE

RVXVRT160GE

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

RVXVHT080GE /

RVXVHT100GE /

RVXVHT120GE /

RVXVHT140GE /

RVXVHT160GE /

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

1

1

3/380~415/50

HP/HR

30

84.0

286,700

94.5

322,500

25.80

25.40

100

3.26

3.72

Propeller/BLDC

19.05

31.75

28.58

6.35

200

50 (40)

R410A

11x2

63

320x2

323x2

337x2

340x2

(1,200x1,703x765)x2

(1,268x1,868x832)x2

-5~43

-20~24

32 HP

2

3/380~415/50

HP/HR

32

89.6

305,800

100.8

344,000

29.60

30.00

100

3.03

3.36

Propeller/BLDC

19.05

31.75

28.58

6.35

200

50 (40)

R410A

11x2

63

320x2

323x2

337x2

340x2

(1,200x1,703x765)x2

(1,268x1,868x832)x2

-5~43

-20~24

34 HP

1

2

3/380~415/50

HP/HR

34

95.2

324,700

107.1

365,500

28.58

25.96

100

3.33

4.13

Propeller/BLDC

19.05

31.75

28.58

6.35

200

50 (40)

R410A

7.5x3

64

240x3

242x3

253x3

255x3

(880x1,703x765)x3

(948x1,868x832)x3

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.- Specifications are subject to change without prior notice for product improvement.

Module Type - CompactModel

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

24 HP

Basic

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

RVXVRT080GE

RVXVRT100GE

RVXVRT120GE

RVXVRT140GE

RVXVRT160GE

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

RVXVHT080GE /

RVXVHT100GE /

RVXVHT120GE /

RVXVHT140GE /

RVXVHT160GE /

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

1

1

3/380~415/50

HP/HR

24

67.2

229,300

75.6

258,000

18.78

17.56

75

3.58

4.31

Propeller/BLDC

15.88

28.58

25.40

6.35

200

50 (40)

R410A

7.5x1+11x1

62

240x1+320x1

242x1+323x1

253x1+337x1

255x1+340x1

(880x1,703x765)x1+(1,200x1,703x765)x1

(948x1,868x832)x1+(1,268x1,868x832)x1

-5~43

-20~24

26 HP

1

1

3/380~415/50

HP/HR

26

72.8

248,400

81.9

279,500

21.40

19.80

75

3.40

4.14

Propeller/BLDC

19.05

31.75

28.58

6.35

200

50 (40)

R410A

7.5x1+11x1

62

240x1+320x1

242x1+323x1

253x1+337x1

255x1+340x1

(880x1,703x765)x1+(1,200x1,703x765)x1

(948x1,868x832)x1+(1,268x1,868x832)x1

-5~43

-20~24

28 HP

2

3/380~415/50

HP/HR

28

78.4

267,600

88.2

301,000

22.00

20.80

75

3.56

4.24

Propeller/BLDC

19.05

31.75

28.58

6.35

200

50 (40)

R410A

11x2

63

320x2

323x2

337x2

340x2

(1,200x1,703x765)x2

(1,268x1,868x832)x2

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.- Specifications are subject to change without prior notice for product improvement.

Module Type - Compact

Page 19: DVM Catalog

Outdoor Units - DVM PLUS III / HR

2008 SAMSUNG DVM Air Conditioners Outdoor Units

36 37

Outdoor U

nits

Specification | DVM PLUS III / HR

Model

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

42 HP

Basic

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

RVXVRT080GE

RVXVRT100GE

RVXVRT120GE

RVXVRT140GE

RVXVRT160GE

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

RVXVHT080GE /

RVXVHT100GE /

RVXVHT120GE /

RVXVHT140GE /

RVXVHT160GE /

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

1

1

1

3/380~415/50

HP/HR

42

117.6

401,300

132.3

451,500

36.20

34.80

125

3.25

3.80

Propeller/BLDC

19.05

38.10

31.75

6.35

200

50 (40)

R410A

7.5x1+11x2

64

240x1+320x2

242x1+323x2

253x1+337x2

255x1+340x2

(880x1,703x765)x1+(1,200x1703x765)x2

(948x1,868x832)x1+(1,268x1748x832)x2

-5~43

-20~24

44 HP

2

1

3/380~415/50

HP/HR

44

123.2

420,500

138.6

473,000

36.80

35.80

125

3.35

3.87

Propeller/BLDC

19.05

38.10

31.75

6.35

200

50 (40)

R410A

11x3

65

320x3

323x3

337x3

340x3

(1,200x1,703x765)x3

(1,268x1,868x832)x3

-5~43

-20~24

46 HP

1

2

3/380~415/50

HP/HR

46

128.8

439,600

144.9

494,500

40.60

40.40

125

3.17

3.59

Propeller/BLDC

19.05

38.10

31.75

6.35

200

50 (40)

R410A

11x3

65

320x3

323x3

337x3

340x3

(1,200x1,703x765)x3

(1,268x1,868x832)x3

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.- Specifications are subject to change without prior notice for product improvement.

Module Type - CompactModel

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

36 HP

Basic

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

RVXVRT080GE

RVXVRT100GE

RVXVRT120GE

RVXVRT140GE

RVXVRT160GE

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

RVXVHT080GE /

RVXVHT100GE /

RVXVHT120GE /

RVXVHT140GE /

RVXVHT160GE /

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

3

3/380~415/50

HP/HR

36

100.8

343,800

113.4

387,000

31.20

28.20

100

3.23

4.02

Propeller/BLDC

19.05

38.10

31.75

6.35

200

50 (40)

R410A

7.5x3

64

240x3

242x3

253x3

255x3

(880x1,703x765)x3

(948x1,868x832)x3

-5~43

-20~24

38 HP

2

1

3/380~415/50

HP/HR

38

106.4

363,000

119.7

408,500

31.80

29.20

125

3.35

4.10

Propeller/BLDC

19.05

38.10

31.75

6.35

200

50 (40)

R410A

7.5x2+11x1

64

240x2+320x1

242x2+323x1

253x2+337x1

255x2+340x1

(880x1,703x765)x2+(1,200x1,703x765)x1

(948x1,868x832)x2+(1,268x1,868x832)x1

-5~43

-20~24

40 HP

2

1

3/380~415/50

HP/HR

40

112.0

382,100

126.0

430,000

35.60

33.80

125

3.15

3.73

Propeller/BLDC

19.05

38.10

31.75

6.35

200

50 (40)

R410A

7.5x2+11x1

64

240x2+320x1

242x2+323x1

253x2+337x1

255x3+340x1

(880x1,703x765)x2+(1,200x1,703x765)x1

(948x1,868x832)x2+(1,268x1,868x832)x1

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.- Specifications are subject to change without prior notice for product improvement.

Module Type - Compact

Page 20: DVM Catalog

Outdoor Units - DVM PLUS III / HR 38 39

Outdoor U

nits

2008 SAMSUNG DVM Air Conditioners Outdoor Units

Specification | DVM PLUS III / HR

Model

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

54 HP

Basic

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

RVXVRT080GE

RVXVRT100GE

RVXVRT120GE

RVXVRT140GE

RVXVRT160GE

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

RVXVHT080GE /

RVXVHT100GE /

RVXVHT120GE /

RVXVHT140GE /

RVXVHT160GE /

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

1

1

2

3/380~415/50

HP/HR

54

151.2

515,900

170.1

580,500

47.78

46.56

150

3.16

3.65

Propeller/BLDC

22.23

44.50

38.10

6.35

200

50 (40)

R410A

7.5x2+11x2

66

240x2+320x2

242x2+323x2

253x2+337x2

255x2+340x2

(880x1,703x765)x2+(1,200x1,703x765)x2

(948x1,868x832)x2+(1,268x1,868x832)x2

-5~43

-20~24

56 HP

1

1

2

3/380~415/50

HP/HR

56

156.8

535,100

176.4

602,000

48.38

47.56

150

3.24

3.71

Propeller/BLDC

22.23

44.50

38.10

6.35

200

50 (40)

R410A

7.5x1+11x3

66

240x1+320x3

242x1+323x3

253x1+337x3

255x1+340x3

(880x1,703x765)x1+(1,200x1,703x765)x3

(948x1,868x832)x1+(1,268x1,868x832)x3

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.- Specifications are subject to change without prior notice for product improvement.

Module Type - CompactModel

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

48 HP

Basic

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

RVXVRT080GE

RVXVRT100GE

RVXVRT120GE

RVXVRT140GE

RVXVRT160GE

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

RVXVHT080GE /

RVXVHT100GE /

RVXVHT120GE /

RVXVHT140GE /

RVXVHT160GE /

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

3

3/380~415/50

HP/HR

48

134.4

458,700

151.2

516,000

44.40

45.00

125

3.03

3.36

Propeller/BLDC

19.05

38.10

31.75

6.35

200

50 (40)

R410A

11x3

65

320x3

323x3

337x3

340x3

(1,200x1,703x765)x3

(1,268x1,868x832)x3

-5~43

-20~24

50 HP

3

1

3/380~415/50

HP/HR

50

140.0

477,600

157.5

537,500

42.20

38.60

150

3.32

4.08

Propeller/BLDC

22.23

44.50

38.10

6.35

200

50 (40)

R410A

7.5x3+11x1

66

240x3+320x1

242x3+323x1

253x3+337x1

255x3+340x1

(880x1,703x765)x3+(1,200x1,703x765)x1

(948x1,868x832)x3+(1,268x1,868x832)x1

-5~43

-20~24

52 HP

3

1

3/380~415/50

HP/HR

52

145.6

496,700

163.8

559,000

46.00

43.20

150

3.17

3.79

Propeller/BLDC

22.23

44.50

38.10

6.35

200

50 (40)

R410A

7.5x3+11x1

66

240x3+320x1

242x3+323x1

253x3+337x1

255x3+340x1

(880x1,703x765)x3+(1,200x1,703x765)x1

(948x1,868x832)x3+(1,268x1,868x832)x1

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.- Specifications are subject to change without prior notice for product improvement.

Module Type - Compact

Page 21: DVM Catalog

Outdoor Units - DVM PLUS III / HR

2008 SAMSUNG DVM Air Conditioners Outdoor Units

40 41

Outdoor U

nits

Specification | DVM PLUS III / HR

Model

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

62 HP

Basic

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

RVXVRT080GE

RVXVRT100GE

RVXVRT120GE

RVXVRT140GE

RVXVRT160GE

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

RVXVHT080GE /

RVXVHT100GE /

RVXVHT120GE /

RVXVHT140GE /

RVXVHT160GE /

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

1

3

3/380~415/50

HP/HR

62

173.6

592,500

195.3

666,500

55.40

55.40

175

3.13

3.53

Propeller/BLDC

22.23

44.50

38.10

6.35

200

50 (40)

R410A

11x4

67

320x4

323x4

337x4

340x4

(1,200x1,703x765)x4

(1,268x1,868x832)x4

-5~43

-20~24

64 HP

4

3/380~415/50

HP/HR

64

179.2

611,600

201.6

688,000

59.20

60.00

175

3.03

3.36

Propeller/BLDC

22.23

44.50

38.10

6.35

200

50 (40)

R410A

11x4

67

320x4

323x4

337x4

340x4

(1,200x1,703x765)x4

(1,268x1,868x832)x4

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

Module Type - CompactModel

Power supply

Mode *1)

Performance

Power

COP

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating

Temp. Range

58 HP

Basic

Horse Power

Capacity

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type/Control

Liquid

Gas

Discharge Gas (DVM PLUS III HR)

Oil (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

RVXVRT080GE

RVXVRT100GE

RVXVRT120GE

RVXVRT140GE

RVXVRT160GE

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

kW

kW

A

-

-

-

Ø,mm

Ø,mm

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

kg

kg

mm

mm

ºC

ºC

RVXVHT080GE /

RVXVHT100GE /

RVXVHT120GE /

RVXVHT140GE /

RVXVHT160GE /

Cooling *2)

Heating *3)

Cooling

Heating

Max.Length

Max.Height

DVM PLUS III

DVM PLUS III HR

DVM PLUS III

DVM PLUS III HR

1

3

3/380~415/50

HP/HR

58

162.4

554,200

182.7

623,500

52.18

52.16

150

3.11

3.50

Propeller/BLDC

22.23

44.50

38.10

6.35

200

50 (40)

R410A

7.5x1+11x3

66

240x1+320x3

242x1+323x3

253x1+337x3

255x1+340x3

(880x1,703x765)x1+(1,200x1,703x765)x3

(948x1,868x832)x1+(1,268x1,868x832)x3

-5~43

-20~24

60 HP

1

3

3/380~415/50

HP/HR

60

168.0

573,300

189.0

645,000

54.80

54.40

175

3.07

3.47

Propeller/BLDC

22.23

44.50

38.10

6.35

200

50 (40)

R410A

7.5x1+11x3

67

240x1+320x3

242x1+323x3

253x1+337x3

255x1+340x3

(880x1,703x765)x1+(1,200x1,703x765)x3

(948x1,868x832)x1+(1,268x1,868x832)x3

-5~43

-20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

Module Type - Compact

Page 22: DVM Catalog

Outdoor Units - Mini DVM

2008 SAMSUNG DVM Air Conditioners Outdoor Units

42 43

Outdoor U

nits

Mini DVMMini DVM is a highly compact and reliable unit for luxurious residentialbuildings or light commercial applications with a Digital Scroll Compressorwhich ensures high energy efficiency.

Slim and Flexible

High Energy EfficiencyDigital Scroll compressor offers very high cooling and heating COP.

Compact DesignMini DVM offers easy installation with its slim and compactdesign saving installation space.

• High energy-efficient system

• Compact outdoor unit

• Wide Compatibility

• Ø1, 220~240V, 50Hz (4/5HP)• Ø3, 380~415V, 50Hz (5/6HP)

4

CO

P

3

2

1

04HP 5HP 6HP

3.33

4.05

3.04

3.87

3.053.73

Dimension

Capacity

Volume (m3)

Foot print (m2)

Height (mm)

Weight (kg)

4Hp

0.39

0.35

1,128

124

5Hp

0.39

0.35

1,128

125

6Hp

0.39

0.35

1,128

125

Various Indoor UnitsMini DVM can be combined up to 9 stylish indoor unitsblending with any interior design.

Easy MaintenanceMini DVM makes it possible to control compressor, PCB, EEVon front panel allowing simple and effortless maintenance. It is possible to react promptly to errors because they are displayed on LED of the outdoor units by error codes.

Cooling

Heating

Wide CompatibilityMini DVM can be controlled by a control solution which is

the same with that of DVM PLUS III and FJM

High ReliabilityMini DVM is highly reliable with adopted Digital ScrollCompressor which can be controlled easily.Because Digital Scroll Compressor needs just one controlPCB, it achieves simple structure and high reliability.

Page 23: DVM Catalog

Outdoor Units - Mini DVM

2008 SAMSUNG DVM Air Conditioners Outdoor Units

44 45

Outdoor U

nits

Specification | Mini DVM

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

Power Supply

Mode *1)

Performance

Power

COP

Compressor

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating Temp.

Range

RVXMHF040EA

Horse Power

Capacity

Nominal Running

Current

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type

Piston Displacement

Output

Lubricant

Type

Output

Airflow Rate

Liquid (Flare)

Gas (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure(Cooling/Heating) *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

A

A

kW

kW

A

-

-

-

cc/Rev

kW

-

cc

-

W

m3/min

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

mm

mm

ºC

ºC

Cooling *2)

Heating *3)

Cooling

Heating

Cooling

Heating

Type

Charging

Max. Length

Max. Height

1/220~240/50

HP

4

12.5

42,600

14.5

49,400

19.0

18.0

3.75

3.58

30

3.33

4.05

Digital Scroll

58.10

-

3MAF POE

1,893

Propeller

200x2

105

9.52

15.88

100

30

R410A

5.5

55/56

124

132

932x1,128x375

1,091x1,286x472

-5~43

-20~24

RVXMHF050EA

1/220~240/50

HP

5

14.0

47,700

16.0

54,500

22.4

20.1

4.60

4.13

30

3.04

3.87

Digital Scroll

62.98

-

3MAF POE

1,893

Propeller

200x2

105

9.52

15.88

100

30

R410A

5.5

55/57

125

133

932x1,128x375

1,091x1,286x472

-5~43

-20~24

RVXMHF050GA

3/380~415/50

HP

5

14.0

47,700

16.0

45,500

8.5

7.8

4.61

4.13

20

3.04

3.87

Digital Scroll

67.13

-

3MAF POE

1,893

Propeller

200x2

105

9.52

15.88

100

30

R410A

5.5

55/57

125

133

932x1,128x375

1,091x1,286x472

-5~43

-20~24

RVXMHF060GA

3/380~415/50

HP

6

16.0

54,500

18.0

61,400

11.0

9.9

5.24

4.82

20

3.05

3.73

Digital Scroll

77.20

-

3MAF POE

1,774

Propeller

220x2

105

9.52

15.88

100

30

R410A

5.5

57/60

125

133

932x1,128x375

1,091x1,286x472

-5~43

-15~24

Model

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

Power Supply

Mode *1)

Performance

Power

COP

Compressor

Fan

Piping

Connections

Refrigerant

Sound

Set Size

Operating Temp.

Range

Horse Power

Capacity

Nominal Running

Current

Nominal Input

Circuit Breaker (MCCB/ELB)

Cooling

Heating

Type

Piston Displacement

Output

Lubricant

Type

Output

Airflow Rate

Liquid (Flare)

Gas (Flare)

Installation

Limitation

Type

Factory Charging

Sound Pressure(Cooling/Heating) *4)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Cooling

Heating

Ø/V/Hz

-

HP

kW

Btu/h

kW

Btu/h

A

A

kW

kW

A

-

-

-

cc/Rev

kW

-

cc

-

W

m3/min

Ø,mm

Ø,mm

m

m

-

kg

dB(A)

kg

kg

mm

mm

ºC

ºC

Cooling *2)

Heating *3)

Cooling

Heating

Cooling

Heating

Type

Charging

Max. Length

Max. Height

Model RVMMH120EZ

1/220~240/50

HP

4

12.0

40,900

14.0

47,700

18.0

18.0

3.56

3.58

-

3.37

3.91

Digital Scroll

-

-

SONTEX 200LT

-

Propeller

-

95

9.52

19.05

70

30

R22

6.5

55/56

124

132

932x1,128x375

1,091x1,286x472

-5~43

-15~24

RVMMH120GZ

3/380~415/50

HP

4

12.0

40,900

14.0

47,700

6.5

6.4

3.80

3.58

-

3.16

3.91

Digital Scroll

82.59

-

SONTEX 200LT

1,890

Propeller

-

95

9.52

19.05

70

30

R22

6.5

55/59

124

132

932x1,128x375

1,091x1,286x472

-5~43

-15~24

RVMMH140EZ

1/220~240/50

HP

5

14.0

47,700

16.0

54,500

22.5

21.5

4.65

4.50

-

3.01

3.56

Digital Scroll

93.03

-

SONTEX 200LT

1,890

Propeller

-

95

9.52

19.05

70

30

R22

6.5

55/57

125

133

932x1,128x375

1,091x1,286x472

-5~43

-15~24

RVMMH140GZ

3/380~415/50

HP

5

14.0

47,700

16.0

54,550

8.5

8.0

4.90

4.30

-

2.86

3.72

Digital Scroll

98.06

4.2

SONTEX 200LT

1,890

Propeller

-

95

9.52

19.05

70

30

R22

6.5

55/57

125

133

932x1,128x375

1,091x1,286x472

-5~43

-15~24

RVMMH160GZ

3/380~415/50

HP

6

16.0

54,500

18.0

61,400

10.2

9.9

5.55

5.20

-

2.89

3.46

Digital Scroll

107.80

-

SONTEX 200LT

1,890

Propeller

-

95

9.52

19.05

70

30

R22

6.5

57/60

125

133

932x1,128x375

1,091x1,286x472

-5~43

-15~24

Page 24: DVM Catalog

Outdoor Units - Free Joint Multi

2008 SAMSUNG DVM Air Conditioners Outdoor Units

46 47

Outdoor U

nits

Free Joint MultiFree Joint Multi supports various combinations of indoor and outdoorunits, providing variety of choices and flexible installation. Therefore,Free Joint Multi is the best solution for residential buildings seekingflexible, efficient and reliable air conditioning system.

High Energy Efficiency

BLDC(Twin Rotary) Compressor

Highly Efficient BLDC Motor

- Creative motor core design- High density neodymium magnet- Concentrated type stator

Extremely Low Vibration

- Twin eccentric cams- 2 balance weights

Highly Stable Moving Parts

- Optimal material matching rollers andvanes

- Highly robust bearings- Coated vane- Coated shaft

Wide Operation Range ofOutdoor Temperature

High Performance

TBR Sine-Wave CompressorNew FJM models have applied the twin BLDC compressor with highlystable moving parts which reduced torque variation by 70% comparedto the conventional single BLDC compressor.

Conventional New

Felt StructureNew felt has been selected to reduce the noise coming out of the compressor. Double layered felt structure absorbs noise by two times andfelt is also covering top of the compressor to reduce the noise even more.

Sine Wave ControllerAll the FJM models have adopted this newly developed Sine Wave Controller. No nipple in the current wavemakes soft acoustic quality and reduces noise.

BLDC Compressor is applied on all FJM outdoor models. Current Wave

Torque Ripple

Current Wave

Torque Ripple

Current Wave

Torque Ripple

Current Wave

Torque Ripple

Conventional Square Wave Controller New Sine Wave Controller

Page 25: DVM Catalog

Outdoor Units - Free Joint Multi 48 49

2008 SAMSUNG DVM Air Conditioners Outdoor Units

Outdoor U

nits

Indoor Unit

Model

MH026FBEA

MH035FBEA

MH052FBEA

MH020FVEA

MH026FVEA

MH035FVEA

MH052FVEA

MH020FNEA

MH026FNEA

MH035FNEA

MH052FNEA

MH026FJEA

MH035FJEA

MH026FKEA

MH035FKEA

MH030FMEA

MH035FMEA

MH052FMEA

MH026FEEA

MH035FEEA

MH052FUEA

Line upAvailable Outdoor Units

Combination Table

MH040FXEA2B4.0kW

2 Unit

MH050FXEA2B5.0kW

2 Unit

MH060FXEA3B6.0kW

3 Unit

MH070FXEA4B7.0kW

4 Unit

MH080FXE4B8.0kW

4 Unit

Outdoor Unit

MH040FXEA2B MH050FXEA2B MH060FXEA3B MH070FXEA4B MH080FXEA4B

Power Supply

Mode *1)

Max number of connectable indoor units

Performance

Sound

Power

Compressor

Refrigerant

Fan

Set Size

Piping

Connections

Operating

Temp. Range

MH040FXEA2B

Horse Power

Capacity

Sound Pressure (Cooling/Heating) *4)

Running

Current

Nominal Input

Circuit Breaker(MCCB/ELB)

Type

Piston Displacement

Output

Lubricant

Type

Factory Charging

Type

Output

Airflow Rate

Net Weight

Shipping Weight

Net Dimensions(WxHxD)

Shipping Dimensions(WxDxH)

Liquid(Flare)

Gas(Flare)

Installation

Limitation

Cooling

Heating

Ø/V/Hz

-

-

HP

kW

Btu/h

kW

Btu/h

dB(A)

A

A

W

W

A

-

cc/Rev

kW

-

cc

-

kg

-

W

m3/min

kg

kg

mm

mm

Ø,mm

Ø,mm

m

m

ºC

ºC

Cooling *2)

Heating *3)

Cooling

Heating

Cooling

Heating

Type

Charging

Max. Length

Max. Height

1/220~240/50

HP

2

1.5

3.9

13,307

4.4

15,013

47/48

5.2

5.1

1,140

1,120

9

TWIN BLDC INV.

19.52

5.86

POE

700

R410A

1.3

Propeller

25

25.4

41

44

790X548X285

926X630X382

6.35X2

9.52X2

30

15

-5~43

-15~24

MH050FXEA2B

1/220~240/50

HP

2

1.8

5.0

17,060

5.7

19,448

48/50

6.1

6.4

1,330

1,400

13.5

TWIN BLDC INV.

19.52

5.86

POE

700

R410A

2

Propeller

40

32.9

53

57

880X638X310

1,023X695X413

6.35X2

9.52X1+12.70X1

30

15

-5~43

-15~24

MH060FXEA3B

1/220~240/50

HP

3

2.0

5.9

20,131

6.3

21,496

49/50

7.3

6.4

1,600

1,400

14.5

TWIN BLDC INV.

19.52

5.86

POE

700

R410A

2.2

Propeller

130

41

59

63

880X798X310

1,023X889X413

6.35X3

9.52X2+12.70X1

45

15

-5~43

-15~24

MH070FXEA4B*5)

1/220~240/50

HP

4

2.5

7.0

23,884

8.6

29,343

50/51

8.7

9.2

1,900

2,000

16.6

TWIN BLDC INV.

25.18

7.77

POE

700

R410A

2.8

Propeller

130

44.8

65

70

880X798X310

1,023X889X413

6.35X4

9.52X2+12.70X2

70

15

-5~43

-15~24

MH080FXEA4B*5)

1/220~240/50

HP

4

3.0

8.0

27,296

9.3

31,732

51/51

10.5

10.1

2,300

2,200

16.6

TWIN BLDC INV.

25.18

7.77

POE

700

R410A

2.8

Propeller

130

45.4

65

70

880X798X310

1,023X889X413

6.35X4

9.52X2+12.70X2

70

15

-5~43

-15~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.

Model

Specification | Outdoor Units

Page 26: DVM Catalog

Specification | Indoor Units

Notes*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.

Power SupplyMode *1)

Performance

SoundPower

Piping

Set Size

Accessories

Cooling *2)

Heating *3)

Sound Pressure (High/Low) *4)

Fan

Running CurrentPower InputConnecting Pipe

Net WeightShipping WeightNet Dimensions (WxHxD)Shipping Dimensions (WxHxD)PanelFilterDrain Pump

Model

Ø/V/Hz

kWBtu/hkWBtu/hdB(A)-m3/min

mmAq

AWØ,mmØ,mmØ,mmkgkgmmmm---

MH020FNEA MH026FNEA MH035FNEA MH052FNEA

1/220~240/50HP2.6

8,8712.9

9,89532/23 *5)

Cross Flow Fan8.31/8.56

-

0.18/0.1830/306.359.52 ID 187.89.4

825X285X189900X349X252

---

1/220~240/50HP3.5

11,9423.8

12,96636/23 *5)

Cross Flow Fan9.54/9.93

-

0.19/0.1935/356.359.52 ID 187.8 9.4

825X285X189900X349X252

---

1/220~240/50HP5.2

17,7425.6

19,10740/30 *5)

Cross Flow Fan13.21/14.22

-

0.3/0.350/506.3512.70 ID 1813.0 16.0

1,099X315X2171,137X377X299

---

1/220~240/50HP2

6,8242.2

7,50632/23 *5)

Cross Flow Fan7.73/8

-

0.18/0.1830/306.359.52 ID 187.89.4

825X285X189900X349X252

---

TypeAirflow Rate(Cool/Heat)External StaticPressure(Standard/High)Cooling/HeatingCooling/HeatingLiquid(Flare)Gas(Flare)Drain

Neo Forte

Power SupplyMode *1)

Performance

SoundPower

Piping

Set Size

Accessories

Cooling *2)

Heating *3)

Sound Pressure (High/Low) *4)

Fan

Running CurrentPower InputConnecting Pipe

Net WeightShipping WeightNet Dimensions (WxHxD)Shipping Dimensions (WxHxD)PanelFilterDrain Pump

Model

Ø/V/Hz-kWBtu/hkWBtu/hdB(A)-m3/min

mmAq

AWØ,mmØ,mmØ,mmkgkgmmmm---

MH020FVEA MH026FVEA MH035FVEA MH052FVEA

1/220~240/50HP2.6

8,8712.9

9,89531/21 *5)

Cross Flow Fan8.5/8.3

-

0.18/0.1830/306.359.52 ID 188.5 11.5

825X285X189900X349X252

---

1/220~240/50HP3.5

11,9423.8

12,96635/21 *5)

Cross Flow Fan10/10.4

-

0.19/0.1935/356.359.52 ID 188.5 11.5

825X285X189900X349X252

---

1/220~240/50HP5.2

17,7425.6

19,10740/30 *5)

Cross Flow Fan14.8/14.8

-

0.3/0.350/506.3512.70 ID 1812.0 15.0

1,065X298X2141,137X377X299

---

1/220~240/50HP2

6,8242.2

7,50631/21 *5)

Cross Flow Fan7.5/8.1

-

0.18/0.1830/306.359.52 ID 188.5 11.5

825X285X189900X349X252

---

TypeAirflow Rate(Cool/Heat)External StaticPressure(Standard/High)Cooling/HeatingCooling/HeatingLiquid(Flare)Gas(Flare)Drain

Vivace

Notes*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.

Outdoor Units - Free Joint Multi 50 51

Outdoor U

nits

2008 SAMSUNG DVM Air Conditioners Outdoor Units

1Way Cassette

MB

Power SupplyMode *1)

Performance

SoundPower

Piping

Set Size

Accessories

Cooling *2)

Heating *3)

Sound Pressure (High/Low) *4)

Fan

Running CurrentPower InputConnecting Pipe

Net WeightShipping WeightNet Dimensions (WxHxD)Shipping Dimensions (WxHxD)PanelFilterDrain Pump

Model

Ø/V/Hz-kWBtu/hkWBtu/hdB(A)-m3/min

mmAq

AWØ,mmØ,mmØ,mmkgkgmmmm---

MH026FBEA MH035FBEA MH052FBEA

1/220~240/50HP3.5

11,9423.8

12,96635/21 *5)

Cross Flow Fan9.16/9.46

-

0.19/0.1935/356.359.52 ID 1810.2 11.5

900X304X185963X349X247

---

1/220~240/50HP5.2

17,7425.6

19,10740/30 *5)

Cross Flow Fan14.98/14.49

-

0.3/0.350/506.3512.70 ID 1813.016.0

1,100X307X2251,157X381X292

---

1/220~240/50HP2.6

8,8712.9

9,89531/20 *5)

Cross Flow Fan8.14/8.23

-

0.18/0.1830/306.359.52 ID 1810.2 11.5

900X304X185963X349X247

---

TypeAirflow Rate(Cool/Heat)External StaticPressure(Standard/High)Cooling/HeatingCooling/HeatingLiquid(Flare)Gas(Flare)Drain

Console

Power SupplyMode *1)

Performance

SoundPower

Piping

Set Size

Accessories

Cooling *2)

Heating *3)

Sound Pressure (High/Low) *4)

Fan

Running CurrentPower InputConnecting Pipe

Net WeightShipping WeightNet Dimensions (WxHxD)Shipping Dimensions (WxHxD)PanelFilterDrain Pump

Model

Ø/V/Hz

kWBtu/hkWBtu/hdB(A)-m3/min

mmAq

AWØ,mmØ,mmØ,mmkgkgmmmm---

MH026FJEA MH035FJEA

1/220~240/50HP3.5

11,9423.8

12,966-

Turbo Fan-

-

--

6.359.52

-14.5 18.5

720x620x199810x710x295

---

1/220~240/50HP2.6

8,8712.9

9,895-

Turbo Fan-

-

--

6.359.52

-14.5 18.5

720x620x199810x710x295

---

TypeAirflow Rate(Cool/Heat)External StaticPressure(Standard/High)Cooling/HeatingCooling/HeatingLiquid(Flare)Gas(Flare)Drain

MH026FKEA MH035FKEA

1/220~240/50HP3.5

11,9003.8

12,90038/35

Cross Flow Fan7.5/8.0

-

0.23/0.2345/456.359.52

VP:20 (OD:26, ID:20)15.0 18.0

970x180x3901,168x302x467Option (P1SMA)

Built-inBuilt-in

1/220~240/50HP2.6

8,8002.9

9,80036/33

Cross Flow Fan7.0/7.5

-

0.20/0.2040/406.359.52

VP:20 (OD:26, ID:20)15.0 18.0

970x180x3901,168x302x467Option (P1SMA)

Built-inBuilt-in

Page 27: DVM Catalog

Specification | Indoor Units

Notes*1) Mode - HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.

Outdoor Units - Free Joint Multi 52 53

Outdoor U

nits

2008 SAMSUNG DVM Air Conditioners Outdoor Units

Mini 4Way Cassette

Power SupplyMode *1)

Performance

Soundpower

Piping

Set Size

Accessories

Cooling *2)

Heating *3)

Sound Pressure (High/Low) *4)

Fan

Running CurrentPower InputConnecting Pipe

Net WeightShipping WeightNet Dimensions (WxHxD)Shipping Dimensions (WxHxD)PanelFilterDrain Pump

Model

Ø/V/Hz

kWBtu/hkWBtu/hdB(A)-m3/min

mmAq

AWØ,mmØ,mmØ,mmkgkgmmmm---

MH030FMEA MH035FMEA MH052FMEA

1/220~240/50HP3.5

11,9003.8

12,90040/37

Turbo Fan10.8/11.7

-

0.37/0.3785/856.359.52

VP:25 (OD:32, ID:25)17.0 20.0

575x242x575660x310x635

PMSMABuilt-inBuilt-in

1/220~240/50HP5.2

17,7005.6

19,10044/40

Turbo Fan12.1/13.6

-

0.52/0.52120/120

6.3512.70

VP:25 (OD:32, ID:25)17.0 20.0

575x242x575660x310x635

PMSMABuilt-inBuilt-in

1/220~240/50HP3.0

10,2003.4

11,60040/37

Turbo Fan10.8/11.7

-

0.37/0.3785/856.359.52

VP:25 (OD:32, ID:25)17.0 20.0

575x242x575660x310x635

PMSMABuilt-inBuilt-in

TypeAirflow Rate(Cool/Heat)External StaticPressure(Standard/High)Cooling/HeatingCooling/HeatingLiquid(Flare)Gas(Flare)Drain

Specification | Pack Multi Split (Forte Type)

Capacity(Cooling/Heating)

Energy Efficiency

Moisture removalAirflow Rate(Max.)

Sound Pressure(Max.)

Power SupplyPower Input(Cooling/Heating)

Running Current(Cooling/Heating)

Net Dimensions(WxHxD)

Net Weight

Shipping Weight

Loading Q’ty(40ft)

SVC Valve

Piping Length

Piping HeightQuantity of RefrigerantAdditional Refrigerant

Good Sleep IISilver Coated Health System

Pure and Clean Air

Operating Mode

Convenience

Etc.Operating Temp. Range

1Unit(A)1Unit(B or C)2Unit[A+(B or C)]1Unit(A)

1Unit(B or C)

2Unit[A+(B or C)]

1Unit(A)1Unit(B or C)Indoor (A-Unit)Indoor (B-Unit or C-Unit)Outdoor Unit

1Unit(A)1Unit(B or C)2Unit[A+(B or C)]1Unit(A)1Unit(B or C)2Unit[A+(B or C)]

Indoor (A-Unit)Indoor (B-Unit or C-Unit)Outdoor UnitIndoor (A-Unit)Indoor (B-Unit or C-Unit)Outdoor UnitIndoor (A-Unit)Indoor (B-Unit or C-Unit)Outdoor Unit

Liquid(A)Gas(A)Liquid(B or C)Gas(B or C)StandardMaxMax

Silver Coated FilterSilver Coated EvaporatorDNA FilterPure Filter(HAF Filter)Catechin FilterDeodorizing FilterDigital i PlusDehumidificationTurbo ModeTimerEnergy Saving ModeAuto RestartAuto ChangeoverAuto WindAirflow Control Steps(Cool/Fan)Air Direction Control(Up/Down)Air Direction Control(Left/Right)Auto GrilleRemote ControllerAuto Clean(Self cleaning)Compressor TypeCoolingHeating

Outdoor unit

Indoor unit

MH18VF1XMH18VF1-09MH18VF1-09

Model

Electrical Data

Dimensions and Loading Q’ty

Technical Information

Features

kWkWkWEERCOPEERCOPEERCOPl/hm3/minm3/mindB(A)dB(A)dB(A)

Ø/V/HzWWWAAA

mmmmmmkgkgkgkgkgkgW/O PipeW/Pipe

Ø,mmØ,mmØ,mmØ,mmmmmkgg/m

°C°C

2.6/2.92.6/2.93.9/4.4

3.47 3.44 3.47 3.443.363.791.68.38.34343

51/52

1/220-240/50750/900750/900

1,160/1,1603.4/4.13.4/4.15.3/5.3

825x285x189825x285x189548x790x285

8.48.441

10.610.644153

-

6.359.526.359.527.5307.51.310

4/3AUTO

MANUAL

Rotary(BLDC)-5~43-15~24

MH19VF1XMH19VF1-07MH19VF1-12

2.1/2.43.5/3.83.9/4.4

3.893.003.023.283.363.791.67.739.54343

51/52

1/220-240/50540/800

1,160/1,1601,160/1,160

2.5/3.75.3/5.35.3/5.3

825x285x189825x285x189548x790x285

8.48.441

10.610.644153

-

6.359.526.359.527.5307.51.310

4/3AUTO

MANUAL

Rotary(BLDC)-5~43

-15~24

Power SupplyMode *1)

Performance

Soundpower

Piping

Set Size

Accessories

Cooling *2)

Heating *3)

Sound Pressure (High/Low) *4)

Fan

Running CurrentPower InputConnecting Pipe

Net WeightShipping WeightNet Dimensions (WxHxD)Shipping Dimensions (WxHxD)PanelFilterDrain Pump

Model

Ø/V/Hz

kWBtu/hkWBtu/hdB(A)-m3/min

mmAq

AWØ,mmØ,mmØ,mmkgkgmmmm---

TypeAirflow Rate(Cool/Heat)External StaticPressure(Standard/High)Cooling/HeatingCooling/HeatingLiquid(Flare)Gas(Flare)Drain

MH026FEEA MH035FEEA

1/220~240/50HP3.5

11,9003.8

12,90032/27

Sirocco Fan9.8/10.3

2/4

0.4/0.480/806.350.92

VP:25 (OD:32, ID:25)26.0 31.0

900x199x6001,133x333x722

-Built-in

MDP-E075SEE

1/220~240/50HP2.6

8,8002.9

9,80031/26

Sirocco Fan8.6/9.0

2/4

0.4/0.480/806.359.52

VP:25 (OD:32, ID:25)26.0 31.0

900x199x6001,133x333x722

-Built-in

MDP-E075SEE

MH052FUEA

1/220~240/50HP5.2

17,7425.6

19,107-

Sirocco Fan-

6/10

--

6.3512.70

-29.5 34.5

900x242x4801,146x363x584

--

MSP-M075SGU3

Slim Duct MSP Duct

Page 28: DVM Catalog

Outdoor Units - Free Joint Multi 54 55

Outdoor U

nits

2008 SAMSUNG DVM Air Conditioners Outdoor Units

MH040FXEA2BIndoor Unit Combination

Numberof Unit

1 Unit

2 Unit

2 Unit

Cooling Capacity(W) Capacity CurrentPower Consumption

ACOP EG

20002600350020002000200026002600

20002600

B

---

20002600350026003500

35002600

C

--------

--

D

--------

--

%

51%67%90%103%118%141%133%156%

141%133%

Total Total

20002600350040004600550052006100

55005200

A

21002600350019501696141819501662

14181950

B

---

19502204248219502238

24821950

C

--------

--

Min.W

12801280130013501500150015001500

15001500

Nom.W

21002600350039003900390039003900

39003900

Max.Ml

25203120420042004200420042004200

42004200

Min.W

400400400420420440440440

440440

Nom.W

540750116011601140116011601140

11601160

Max.W

630880124012501250125012501250

12501250

D

--------

--

21002600350039003900390039003900

39003900

Min.A

2.22.22.22.32.32.42.42.4

2.42.4

Nom.A

2.53.45.35.35.25.35.35.2

5.35.3

Max.A

2.94

5.75.75.75.75.75.7

5.75.7

3.893.473.023.363.423.363.363.42

3.363.36

AABAAAAA

AA

Capacity Combination

Multi Split (Wall Mounted Type)

Indoor Unit CombinationNumberof Unit

1 Unit

2 Unit

2 Unit

Heating Capacity(W) Capacity CurrentPower Consumption

ACOP EG

22002900380022002200220029002900

22002900

B

---

22002900380029003800

38002900

C

--------

--

D

--------

--

%

50%66%86%100%116%136%132%152%

136%132%

Total Total

22002900380044005100600058006700

60005800

A

24003100380022001898161322001904

16132200

B

---

22002502278722002496

27872200

C

--------

--

Min.W

13001300130015001500150015001500

15001500

Nom.W

24003100380044004400440044004400

44004400

Max.Ml

29903450437047004700470047004700

47004700

Min.W

280280280300300300300300

300300

Nom.W

800900116011601160116011601120

11601160

Max.W

9101080142013901420149014901490

14901490

D

--------

--

24003100380044004400440044004400

44004400

Min.A

1.51.51.51.61.61.61.61.6

1.61.6

Nom.A

3.74.15.35.35.35.35.35.1

5.35.3

Max.A

4.24.96.56.46.56.86.86.8

6.86.8

3.003.443.283.793.793.793.793.93

3.793.79

DBCAAAAA

AA

Multi Split (Wall Mounted Type)

MH050FXEA2BIndoor Unit Combination

Numberof Unit

1 Unit

2 Unit

Cooling Capacity(W) Capacity CurrentPower Consumption

ACOP EG

200026003500520020002000200020002600260026003500

B

----

20002600350052002600350052003500

C

------------

D

------------

%

40%52%70%104%80%92%110%144%104%122%156%140%

Total Total

200026003500520040004600550072005200610078007000

A

240026003500500020002000181813892500213116672500

B

----

20002600318236112500286933332500

C

------------

Min.W

128012801280130013501350135015001500150015001500

Nom.W

240026003500500040004600500050005000500050005000

Max.Ml

288031204200520048005200540054005400540054005400

Min.W

400400400400420420420440440440440440

Nom.W

7308001090166012451430149013801500150013301500

Max.W

8809601310174014901720178018001780178018001780

D

------------

240026003500500040004600500050005000500050005000

Min.A

1.91.91.91.9222

2.12.12.12.12.1

Nom.A

3.33.75

7.65.76.56.86.36.96.96.16.9

Max.A

44.468

6.87.98.18.28.18.18.28.1

3.293.253.213.013.213.223.363.623.333.333.763.33

AAABAAAAAAAA

CoolingCooling

Cooling

Heating

Heating

Heating

MH060FXEA3BIndoor Unit Combination

Numberof Unit

1 Unit

2 Unit

3 Unit

Cooling Capacity(W) Capacity CurrentPower Consumption

ACOP EG

2000

2600

3500

5200

2000

2000

2000

2000

2600

2600

2600

3500

3500

2000

2000

2000

2000

2000

2000

2600

2600

B

-

-

-

-

2000

2600

3500

5200

2600

3500

5200

3500

5200

2000

2000

2000

2600

2600

3500

2600

2600

C

-

-

-

-

-

-

-

-

-

-

-

-

-

2000

2600

3500

2600

3500

3500

2600

3500

D

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

%

34%

44%

59%

88%

68%

78%

93%

122%

88%

103%

132%

119%

147%

102%

112%

127%

122%

137%

153%

132%

147%

Total Total

2000

2600

3500

5200

4000

4600

5500

7200

5200

6100

7800

7000

8700

6000

6600

7500

7200

8100

9000

7800

8700

A

2400

2600

3500

5200

2000

2000

1909

1528

2600

2259

1967

2725

2374

1760

1636

1573

1528

1457

1311

1967

1763

B

-

-

-

-

2000

2600

3341

3972

2600

3041

3933

2725

3526

1760

1636

1573

1986

1894

2294

1967

1763

C

-

-

-

-

-

-

-

-

-

-

-

-

-

1760

2127

2753

1986

2549

2294

1967

2374

Min.W

1280

1280

1280

1300

1300

1300

1300

1380

1300

1300

1380

1300

1380

1500

1500

1500

1500

1500

1500

1500

1500

Nom.W

2400

2600

3500

5200

4000

4600

5250

5500

5200

5300

5900

5450

5900

5280

5400

5900

5500

5900

5900

5900

5900

Max.Ml

2880

3120

4200

5800

4800

5520

6290

6600

5800

6400

6800

6560

6800

6380

6490

6800

6600

6800

6800

6800

6800

Min.W

400

400

400

400

420

420

430

430

420

430

430

430

440

430

430

440

430

440

440

440

440

Nom.W

730

790

1070

1620

1240

1410

1550

1580

1620

1550

1610

1570

1620

1550

1560

1610

1580

1610

1610

1600

1600

Max.W

930

1010

1370

1900

1480

1680

1820

1850

1800

1840

1880

1850

1880

1840

1850

1880

1850

1880

1880

1880

1880

D

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2400

2600

3500

5200

4000

4600

5250

5500

5200

5300

5900

5450

5900

5280

5400

5900

5500

5900

5900

5900

5900

Min.A

2.2

2.2

2.2

2.2

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.4

2.3

2.3

2.4

2.3

2.4

2.4

2.4

2.4

Nom.A

3.3

3.6

4.9

7.4

5.7

6.5

7.1

7.2

7.4

7.1

7.4

7.2

7.4

7.1

7.1

7.4

7.2

7.4

7.4

7.3

7.3

Max.A

4.3

4.6

6.3

8.7

6.8

7.7

8.3

8.5

8.2

8.4

8.6

8.5

8.6

8.4

8.5

8.6

8.5

8.6

8.6

8.6

8.6

3.29

3.29

3.27

3.21

3.23

3.26

3.39

3.48

3.21

3.42

3.66

3.47

3.64

3.41

3.46

3.66

3.48

3.66

3.66

3.69

3.69

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

Indoor Unit CombinationNumberof Unit

1 Unit

2 Unit

3 Unit

Heating Capacity(W) Capacity CurrentPower Consumption

ACOP EG

2200

2900

3800

5600

2200

2200

2200

2200

2900

2900

2900

3800

3800

2200

2200

2200

2200

2200

2200

2900

2900

B

-

-

-

-

2200

2900

3800

5600

2900

3800

5600

3800

5600

2200

2200

2200

2900

2900

3800

2900

2900

C

-

-

-

-

-

-

-

-

-

-

-

-

-

2200

2900

3800

2900

3800

3800

2900

3800

D

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

%

35%

46%

60%

89%

70%

81%

95%

124%

92%

106%

135%

121%

149%

105%

116%

130%

127%

141%

156%

138%

152%

Total Total

2200

2900

3800

5600

4400

5100

6000

7800

5800

6700

8500

7600

9400

6600

7300

8200

8000

8900

9800

8700

9600

A

2500

2900

3800

5600

2200

2200

2053

1692

2900

2510

2149

2950

2547

1933

1778

1690

1650

1557

1414

2100

1903

B

-

-

-

-

2200

2900

3547

4308

2900

3290

4151

2950

3753

1933

1778

1690

2175

2053

2443

2100

1903

C

-

-

-

-

-

-

-

-

-

-

-

-

-

1933

2344

2920

2175

2690

2443

2100

2494

Min.W

1300

1300

1300

1350

1400

1400

1500

1500

1400

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

Nom.W

2500

2900

3800

5600

4400

5100

5600

6000

5800

5800

6300

5900

6300

5800

5900

6300

6000

6300

6300

6300

6300

Max.Ml

2990

3340

4370

6300

5060

5870

6440

6900

6300

6770

7300

6880

7300

6760

6840

7300

6920

7300

7300

7300

7300

Min.W

350

350

350

350

350

350

350

350

350

350

350

350

350

350

350

350

350

350

350

350

350

Nom.W

880

1030

1350

1820

1220

1490

1640

1660

1700

1700

1740

1730

1740

1590

1610

1660

1590

1630

1560

1650

1400

Max.W

1110

1270

1660

1920

1510

1830

1860

1860

1910

1900

1830

1860

1830

1840

1840

1830

1840

1830

1830

1830

1830

D

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2500

2900

3800

5600

4400

5100

5600

6000

5800

5800

6300

5900

6300

5800

5900

6300

6000

6300

6300

6300

6300

Min.A

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

1.9

Nom.A

4

4.7

6.2

8.3

5.6

6.8

7.5

7.6

7.8

7.8

8

7.9

8

7.3

7.4

7.6

7.3

7.5

7.1

7.6

6.4

Max.A

5.1

5.8

7.6

8.8

6.9

8.4

8.5

8.5

8.7

8.7

8.4

8.5

8.4

8.4

8.4

8.4

8.4

8.4

8.4

8.4

8.4

2.84

2.82

2.81

3.08

3.61

3.42

3.41

3.61

3.41

3.41

3.62

3.41

3.62

3.65

3.66

3.80

3.77

3.87

4.04

3.82

4.50

D

D

D

D

A

B

B

A

B

B

A

B

A

A

A

A

A

A

A

A

A

Indoor Unit CombinationNumberof Unit

1 Unit

2 Unit

Heating Capacity(W) Capacity CurrentPower Consumption

ACOP EG

220029003800560022002200220022002900290029003800

B

----

22002900380056002900380056003800

C

------------

D

------------

%

39%51%67%98%77%89%105%137%102%118%149%133%

Total Total

220029003800560044005100600078005800670085007600

A

250029003800540022002200209016082850246719452850

B

----

22002900361040922850323337552850

C

------------

Min.W

130013001300145014501450150015001500150015001500

Nom.W

250029003800540044005100570057005700570057005700

Max.Ml

299033404370560047505460630064006300630064006300

Min.W

320320320340350350350350350350350350

Nom.W

88010301300181012201410152014401550148014001470

Max.W

101012901620206013901610195018302060194018301890

D

------------

250029003800540044005100570057005700570057005700

Min.A

1.71.71.71.81.91.91.91.91.91.91.91.9

Nom.A

44.75.98.35.66.57

6.67.16.86.46.7

Max.A

4.65.97.49.46.47.48.98.49.48.98.48.6

2.842.822.922.983.613.623.753.963.683.854.073.88

DDDDAAAAAAAA

NoteSpecifications are subject to change without prior notice for product improvement.

NoteSpecifications are subject to change without prior notice for product improvement.

Page 29: DVM Catalog

Outdoor Units - Free Joint Multi 56 57

Outdoor U

nits

2008 SAMSUNG DVM Air Conditioners Outdoor Units

Capacity CombinationCoolingMH070FXEA4B

Indoor Unit CombinationNumberof Unit

1 Unit

2 Unit

3 Unit

4 Unit

Cooling Capacity(W) Capacity CurrentPower Consumption

ACOP EG

2000

2600

3500

5200

2000

2000

2000

2000

2600

2600

2600

3500

3500

5200

2000

2000

2000

2000

2000

2000

2000

2000

2000

2600

2600

2600

2600

3500

2000

2000

2000

2000

2000

2000

2000

2600

B

-

-

-

-

2000

2600

3500

5200

2600

3500

5200

3500

5200

5200

2000

2000

2000

2000

2600

2600

2600

3500

3500

2600

2600

2600

3500

3500

2000

2000

2000

2000

2000

2600

2600

2600

C

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2000

2600

3500

5200

2600

3500

5200

3500

5200

2600

3500

5200

3500

3500

2000

2000

2000

2600

2600

2600

2600

2600

D

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2000

2600

3500

2600

3500

2600

3500

2600

%

29%

37%

50%

74%

57%

66%

79%

103%

74%

87%

111%

100%

124%

149%

86%

94%

107%

131%

103%

116%

140%

129%

153%

111%

124%

149%

137%

150%

114%

123%

136%

131%

144%

140%

153%

149%

Total Total

2000

2600

3500

5200

4000

4600

5500

7200

5200

6100

7800

7000

8700

10400

6000

6600

7500

9200

7200

8100

9800

9000

10700

7800

8700

10400

9600

10500

8000

8600

9500

9200

10100

9800

10700

10400

A

2400

2600

3500

5200

2000

2000

2000

1944

2600

2600

2333

3500

2816

3500

2000

2000

1781

1522

1847

1664

1429

1516

1308

2240

2029

1750

1896

2330

1680

1577

1474

1522

1386

1429

1308

1750

B

-

-

-

-

2000

2600

3500

5056

2600

3500

4667

3500

4184

3500

2000

2000

1781

1522

2401

2163

1857

2652

2290

2240

2029

1750

2552

2330

1680

1577

1474

1522

1386

1857

1701

1750

C

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2000

2600

3118

3957

2401

3119

3714

2652

3120

2240

2732

3121

2552

2330

1680

1577

1474

1978

1802

1857

1701

1750

Min.W

1350

1350

1350

1400

1500

1690

1770

1900

1750

1820

1900

1900

1900

1900

1810

1870

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

Nom.W

2400

2600

3500

5200

4000

4600

5500

7000

5200

6100

7000

7000

7000

7000

6000

6600

6680

7000

6650

6740

7000

6820

7000

6720

6790

7000

7000

6990

6720

6780

7000

7000

7000

7000

7000

7000

3000

3480

4200

6240

4800

5520

6600

8400

6240

7320

8400

8400

8900

8900

7200

7920

8020

8900

7980

8080

8900

8180

8900

8050

8150

8900

8900

8900

8070

8140

8900

8900

8900

8900

8900

8900

Max.Ml

Min.W

380

390

400

420

410

420

430

580

420

440

580

580

580

580

440

440

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

Nom.W

780

840

1130

1520

1240

1430

1710

2180

1660

1880

2130

2120

2110

2000

1800

1830

1835

1850

1830

1840

1880

1850

1930

1840

1850

1880

1880

1900

1850

1880

1900

1880

1900

1900

1930

1900

Max.W

950

1100

1580

2160

1490

1720

2050

2520

2000

2260

2540

2530

2540

2540

2280

2460

2410

2460

2410

2460

2460

2510

2510

2420

2460

2510

2460

2510

2460

2460

2460

2460

2510

2460

2550

2550

D

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

1680

2050

2579

1978

2426

1857

2290

1750

2400

2600

3500

5200

4000

4600

5500

7000

5200

6100

7000

7000

7000

7000

6000

6600

6680

7000

6650

6740

7000

6820

7000

6720

6790

7000

7000

6990

6720

6780

7000

7000

7000

7000

7000

7000

Min.A

1.7

1.8

1.8

1.9

1.9

1.9

2

2.7

1.9

2

2.7

2.7

2.7

2.7

2

2

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

Nom.A

3.6

3.8

5.2

7

5.7

6.5

7.8

10

7.6

8.6

9.7

9.7

9.7

9.2

8.2

8.4

8.4

8.5

8.4

8.4

8.6

8.5

8.8

8.4

8.5

8.6

8.6

8.7

8.5

8.6

8.7

8.6

8.7

8.7

8.8

8.7

Max.A

4.3

5

7.2

9.9

6.8

7.9

9.4

11.5

9.2

10.3

11.6

11.6

11.6

11.6

10.4

11.3

11

11.3

11

11.3

11.3

11.5

11.5

11.1

11.3

11.5

11.3

11.5

11.3

11.3

11.3

11.3

11.5

11.3

11.7

11.7

3.08

3.10

3.10

3.42

3.23

3.22

3.22

3.21

3.13

3.24

3.29

3.30

3.32

3.50

3.33

3.61

3.64

3.78

3.63

3.66

3.72

3.69

3.63

3.65

3.67

3.72

3.72

3.68

3.63

3.61

3.68

3.72

3.68

3.68

3.63

3.68

B

B

B

A

A

A

A

A

B

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

HeatingMH070FXEA4BIndoor Unit Combination

Numberof Unit

1 Unit

2 Unit

3 Unit

4 Unit

Heating Capacity(W) Capacity CurrentPower Consumption

ACOP EG

2200

2600

3800

5600

2200

2200

2200

2200

2900

2900

2900

3800

3800

5600

2200

2200

2200

2200

2200

2200

2200

2200

2200

2900

2900

2900

2900

3800

2200

2200

2200

2200

2200

2200

2200

2900

B

-

-

-

-

2200

2900

3800

5600

2900

3800

5600

3800

5600

5600

2200

2200

2200

2200

2900

2900

2900

3800

3800

2900

2900

2900

3800

3800

2200

2200

2200

2200

2200

2900

2900

2900

C

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2200

2900

3800

5600

2900

3800

5600

3800

5600

2900

3800

5600

3800

3800

2200

2200

2200

2900

2900

2900

2900

2900

D

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2200

2900

3800

2900

3800

2900

3800

2900

%

26%

30%

44%

65%

51%

59%

70%

91%

67%

78%

99%

88%

109%

130%

77%

85%

95%

116%

93%

103%

124%

114%

135%

101%

112%

133%

122%

133%

102%

110%

121%

119%

129%

127%

137%

135%

Total Total

2200

2600

3800

5600

4400

5100

6000

7800

5800

6700

8500

7600

9400

11200

6600

7300

8200

10000

8000

8900

10700

9800

11600

8700

9600

11400

10500

11400

8800

9500

10400

10200

11100

10900

11800

11600

A

2500

2900

3800

5600

2200

2200

2200

2200

2900

2900

2729

3800

3283

4250

2200

2200

2200

1892

2200

2042

1768

1872

1631

2750

2516

2188

2375

2867

2063

1927

1819

1855

1705

1736

1603

2150

B

-

-

-

-

2200

2900

3800

5600

2900

3800

5271

3800

4837

4250

2200

2200

2200

1892

2900

2691

2331

3234

2817

2750

2516

2188

3112

2867

2063

1927

1819

1855

1705

2288

2114

2150

C

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2200

2900

3800

4816

2900

3119

4501

3234

3120

2750

3297

3121

3112

2867

2063

1927

1819

2445

2247

2288

2114

2150

Min.W

1790

1820

1930

2080

1980

2040

2110

2200

2100

2170

2200

2200

2200

2200

2170

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

Nom.W

2500

2900

3800

5600

4400

5100

6000

7800

5800

6700

8000

7600

8120

8500

6600

7300

8200

8600

8000

8260

8600

8340

8600

8250

8330

8600

8600

8600

8250

8320

8600

8600

8600

8600

8600

8600

3220

3680

4600

6440

5060

5870

6900

9130

6670

8040

9600

9120

9740

10200

7590

8400

9590

10300

9360

9670

10300

9760

10300

9650

9740

10300

10300

10300

9660

9730

10300

10300

10300

10300

10300

10300

Max.Ml

Min.W

580

590

600

610

600

610

610

620

610

610

620

620

620

620

610

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

Nom.W

950

1100

1250

1670

1220

1410

1760

2150

1600

1940

2210

2100

2250

2250

1830

1880

1930

1960

1900

1930

1970

1950

2000

1930

1950

1980

1980

2000

1930

1950

2000

1970

2000

2000

2000

2000

Max.W

1330

1500

1810

2370

1530

1700

2110

2700

1930

2330

2650

2510

2700

2740

2530

2590

2660

2700

2620

2660

2720

2690

2760

2660

2690

2730

2730

2760

2660

2690

2760

2720

2760

2760

2760

2760

D

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2063

2540

3142

2445

2944

2288

2769

2150

2500

2900

3800

5600

4400

5100

6000

7800

5800

6700

8000

7600

8120

8500

6600

7300

8200

8600

8000

8260

8600

8340

8600

8250

8330

8600

8600

8600

8250

8320

8600

8600

8600

8600

8600

8600

Min.A

2.7

2.7

2.7

2.8

2.7

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

Nom.A

4.3

5

5.7

7.6

5.6

6.5

8.1

9.8

7.3

8.9

10.1

9.6

10.3

10.3

8.4

8.6

8.8

9

8.7

8.8

9

8.9

9.2

8.8

8.9

9.1

9.1

9.2

8.8

8.9

9.2

9

9.2

9.2

9.2

9.2

Max.A

6.1

6.9

8.3

10.8

7

7.8

9.7

12.4

8.8

10.7

12.1

11.5

12.4

12.5

11.6

11.9

12.2

12.4

12

12.2

12.4

12.3

12.6

12.2

12.3

12.5

12.5

12.6

12.2

12.3

12.6

12.4

12.6

12.6

12.6

12.6

2.63

2.64

3.04

3.35

3.61

3.62

3.41

3.63

3.63

3.45

3.62

3.62

3.61

3.78

3.61

3.88

4.25

4.39

4.21

4.28

4.37

4.28

4.30

4.27

4.27

4.34

4.34

4.30

4.27

4.27

4.30

4.37

4.30

4.30

4.30

4.30

E

E

D

C

A

A

B

A

A

B

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

NoteSpecifications are subject to change without prior notice for product improvement.

NoteSpecifications are subject to change without prior notice for product improvement.

Page 30: DVM Catalog

Outdoor Units - Free Joint Multi 58 59

Outdoor U

nits

2008 SAMSUNG DVM Air Conditioners Outdoor Units

Capacity CombinationCoolingMH080FXEA4B

Indoor Unit CombinationNumberof Unit

1 Unit

2 Unit

3 Unit

4 Unit

Cooling Capacity(W) Capacity CurrentPower Consumption

ACOP EG

2000

2600

3500

5200

2000

2000

2000

2000

2600

2600

2600

3500

3500

5200

2000

2000

2000

2000

2000

2000

2000

2000

2000

2600

2600

2600

2600

2600

3500

3500

2000

2000

2000

2000

2000

2000

2000

2000

2000

2000

2000

2600

2600

2600

B

-

-

-

-

2000

2600

3500

5200

2600

3500

5200

3500

5200

5200

2000

2000

2000

2000

2600

2600

2600

3500

3500

2600

2600

2600

3500

3500

3500

3500

2000

2000

2000

2000

2000

2000

2000

2000

2600

2600

2600

2600

2600

2600

C

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2000

2600

3500

5200

2600

3500

5200

3500

5200

2600

3500

5200

3500

5200

3500

5200

2000

2000

2000

2000

2600

2600

2600

3500

2600

2600

3500

2600

2600

3500

D

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2000

2600

3500

5200

2600

3500

5200

3500

2600

3500

3500

2600

3500

3500

%

25%

33%

44%

65%

50%

58%

69%

90%

65%

76%

98%

88%

109%

130%

75%

83%

94%

115%

90%

101%

123%

113%

134%

98%

109%

130%

120%

141%

131%

153%

100%

108%

119%

140%

115%

126%

148%

138%

123%

134%

145%

130%

141%

153%

Total Total

2000

2600

3500

5200

4000

4600

5500

7200

5200

6100

7800

7000

8700

10400

6000

6600

7500

9200

7200

8100

9800

9000

10700

7800

8700

10400

9600

11300

10500

12200

8000

8600

9500

11200

9200

10100

11800

11000

9800

10700

11600

10400

11300

12200

A

2400

2600

3500

5200

2000

2000

2000

2000

2600

2600

2400

3500

2957

3825

2000

2000

2000

1663

2000

1864

1573

1698

1495

2510

2274

1940

2083

1841

2667

2295

1888

1767

1617

1429

1663

1531

1356

1455

1573

1495

1379

1940

1841

1705

B

-

-

-

-

2000

2600

3500

5200

2600

3500

4800

3500

4393

3825

2000

2000

2000

1663

2600

2423

2046

2971

2617

2510

2274

1940

2804

2478

2667

2295

1888

1767

1617

1429

1663

1531

1356

1455

2046

1944

1793

1940

1841

1705

C

-

-

-

-

-

-

-

-

-

-

-

-

-

2000

2600

3500

4324

2600

3262

4091

2971

3888

2510

3061

3880

2804

3681

2667

3410

1888

1767

1617

1429

2162

1990

1763

2545

2046

1944

2414

1940

1841

2295

Min.W

1470

1520

1600

1750

1640

1690

1770

1900

1750

1820

1900

1900

1900

1900

1810

1870

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

1900

Nom.W

2400

2600

3500

5200

4000

4600

5500

7200

5200

6100

7200

7000

7350

7650

6000

6600

7500

7650

7200

7550

7710

7640

8000

7530

7610

7760

7690

8000

8000

8000

7550

7600

7680

8000

7650

7730

8000

8000

7710

8000

8000

7760

8000

8000

3000

3480

4200

6240

4800

5520

6600

8640

6240

7320

8640

8400

8820

9180

7200

7920

9000

9180

8640

9060

9250

9160

9300

9030

9130

9300

9230

9300

9300

9300

9050

9120

9220

9300

9180

9280

9300

9300

9250

9300

9300

9300

9300

9300

Max.Ml

Min.W

380

390

400

420

410

420

430

580

420

440

580

580

580

580

440

440

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

580

Nom.W

780

840

1130

1520

1240

1430

1710

2240

1660

1900

2240

2180

2290

2380

1850

2000

2220

2190

2150

2150

2190

2190

2260

2110

2140

2210

2180

2260

2260

2300

2140

2140

2180

2300

2190

2200

2300

2280

2190

2260

2300

2220

2300

2300

Max.W

950

1100

1580

2160

1490

1720

2050

2690

2000

2260

2690

2620

2750

2860

2310

2500

2780

2730

2680

2690

2730

2730

2820

2640

2690

2780

2730

2870

2820

2910

2690

2690

2730

2870

2730

2780

2870

2870

2730

2820

2870

2780

2870

2910

D

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

1888

2298

2829

3714

2162

2679

3525

2545

2046

2617

2414

1940

2478

2295

2400

2600

3500

5200

4000

4600

5500

7200

5200

6100

7200

7000

7350

7650

6000

6600

7500

7650

7200

7550

7710

7640

8000

7530

7610

7760

7690

8000

8000

8000

7550

7600

7680

8000

7650

7730

8000

8000

7710

8000

8000

7760

8000

8000

Min.A

1.7

1.8

1.8

1.9

1.9

1.9

2

2.7

1.9

2

2.7

2.7

2.7

2.7

2

2

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

Nom.A

3.6

3.8

5.2

7

5.7

6.5

7.8

10.3

7.6

8.7

10.3

10

10.5

10.9

8.5

9.2

10.2

10

9.8

9.8

10

10

10.3

9.7

9.8

10.1

10

10.3

10.3

10.5

9.8

9.8

10

10.5

10

10.1

10.5

10.4

10

10.3

10.5

10.2

10.5

10.5

Max.A

4.3

5

7.2

9.9

6.8

7.9

9.4

12.3

9.2

10.3

12.3

12

12.6

13.1

10.6

11.4

12.7

12.5

12.3

12.3

12.5

12.5

12.9

12.1

12.3

12.7

12.5

13.1

12.9

13.3

12.3

12.3

12.5

13.1

12.5

12.7

13.1

13.1

12.5

12.9

13.1

12.7

13.1

13.3

3.08

3.10

3.10

3.42

3.23

3.22

3.22

3.21

3.13

3.21

3.21

3.21

3.21

3.21

3.24

3.30

3.38

3.49

3.35

3.51

3.52

3.49

3.54

3.57

3.56

3.51

3.53

3.54

3.54

3.48

3.53

3.55

3.52

3.48

3.49

3.51

3.48

3.51

3.52

3.54

3.48

3.50

3.48

3.48

B

B

B

A

A

A

A

A

B

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

Indoor Unit CombinationNumberof Unit

1 Unit

2 Unit

3 Unit

4 Unit

Heating Capacity(W) Capacity CurrentPower Consumption

ACOP EG

2200

2900

3800

5600

2200

2200

2200

2200

2900

2900

2900

3800

3800

5600

2200

2200

2200

2200

2200

2200

2200

2200

2200

2900

2900

2900

2900

2900

3800

3800

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2900

2900

2900

B

-

-

-

-

2200

2900

3800

5600

2900

3800

5600

3800

5600

5600

2200

2200

2200

2200

2900

2900

2900

3800

3800

2900

2900

2900

3800

3800

3800

3800

2200

2200

2200

2200

2200

2200

2200

2200

2900

2900

2900

2900

2900

2900

C

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2200

2900

3800

5600

2900

3800

5600

3800

5600

2900

3800

5600

3800

5600

3800

5600

2200

2200

2200

2200

2900

2900

2900

3800

2900

2900

3800

2900

2900

3800

D

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2200

2900

3800

5600

2900

3800

5600

3800

2900

3800

3800

2900

3800

3800

%

24%

31%

41%

60%

47%

55%

65%

84%

62%

72%

91%

82%

101%

120%

71%

78%

88%

108%

86%

96%

115%

105%

125%

94%

103%

123%

113%

132%

123%

142%

95%

102%

112%

131%

110%

119%

139%

129%

117%

127%

137%

125%

134%

144%

Total Total

2200

2900

3800

5600

4400

5100

6000

7800

5800

6700

8500

7600

9400

11200

6600

7300

8200

10000

8000

8900

10700

9800

11600

8700

9600

11400

10500

12300

11400

13200

8800

9500

10400

12200

10200

11100

12900

12000

10900

11800

12700

11600

12500

13400

A

2500

2900

3800

5600

2200

2200

2200

2200

2900

2900

2729

3800

3283

4250

2200

2200

2200

1896

2200

2109

1785

1931

1764

2840

2595

2226

2392

2193

2910

2677

2130

1987

1830

1677

1864

1726

1586

1610

1754

1633

1611

2188

2158

2013

B

-

-

-

-

2200

2900

3800

5600

2900

3800

5271

3800

4837

4250

2200

2200

2200

1896

2900

2779

2353

3335

3047

2840

2595

2226

3134

2873

2910

2677

2130

1987

1830

1677

1864

1726

1586

1610

2312

2153

2124

2188

2158

2013

C

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2200

2900

3800

4827

2900

3642

4543

3335

4490

2840

3400

4298

3134

4234

2910

3945

2130

1987

1830

1677

2456

2276

2091

2780

2312

2153

2783

2188

2158

2637

Min.W

1790

1820

1930

2080

1980

2040

2110

2200

2100

2170

2200

2200

2200

2200

2170

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

Nom.W

2500

2900

3800

5600

4400

5100

6000

7800

5800

6700

8000

7600

8120

8500

6600

7300

8200

8620

8000

8530

8680

8600

9300

8520

8590

8750

8660

9300

8730

9300

8520

8580

8650

9300

8640

8710

9300

8780

8690

8760

9300

8750

9300

9300

3220

3680

4600

6440

5060

5870

6900

9130

6670

7710

9360

8740

9500

9950

7590

8400

9590

10090

9360

9980

10150

10070

10900

9960

10050

10900

10130

10900

10220

10900

9970

10040

10120

10900

10100

10190

10900

10270

10170

10250

10900

10240

10900

10900

Max.Ml

Min.W

580

590

600

610

600

610

610

620

610

610

620

620

620

620

610

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

620

Nom.W

950

1110

1250

1670

1220

1410

1760

2150

1600

1940

2210

2090

2250

2340

1830

1950

2150

2140

2080

2100

2140

2140

2150

2090

2100

2140

2140

2150

2150

2180

2100

2100

2140

2200

2140

2140

2200

2180

2140

2180

2200

2140

2180

2200

Max.W

1330

1500

1810

2370

1530

1700

2110

2580

1930

2330

2600

2510

2650

2750

2220

2340

2570

2610

2500

2690

2740

2740

2750

2680

2690

2740

2740

2750

2750

2790

2690

2690

2740

2820

2740

2740

2820

2790

2740

2790

2820

2740

2790

2820

D

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2130

2619

3161

4269

2456

2982

4037

2780

2312

2821

2783

2188

2827

2637

2500

2900

3800

5600

4400

5100

6000

7800

5800

6700

8000

7600

8120

8500

6600

7300

8200

8620

8000

8530

8680

8600

9300

8520

8590

8750

8660

9300

8730

9300

8520

8580

8650

9300

8640

8710

9300

8780

8690

8760

9300

8750

9300

9300

Min.A

2.7

2.7

2.7

2.8

2.7

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

Nom.A

4.3

5.1

5.7

7.6

5.6

6.5

8.1

9.8

7.3

8.9

10.1

9.6

10.3

10.7

8.4

8.9

9.8

9.8

9.5

9.6

9.8

9.8

9.8

9.6

9.6

9.8

9.8

9.8

9.8

10

9.6

9.6

9.8

10.1

9.8

9.8

10.1

10

9.8

10

10.1

9.8

10

10.1

Max.A

6.1

6.9

8.3

10.8

7

7.8

9.7

11.8

8.8

10.7

11.9

11.5

12.1

12.6

10.2

10.7

11.8

11.9

11.4

12.3

12.5

12.5

12.6

12.3

12.3

12.5

12.5

12.6

12.6

12.8

12.3

12.3

12.5

12.9

12.5

12.5

12.9

12.8

12.5

12.8

12.9

12.5

12.8

12.9

2.63

2.61

3.04

3.35

3.61

3.62

3.41

3.63

3.63

3.45

3.62

3.64

3.61

3.63

3.61

3.74

3.81

4.03

3.85

4.06

4.06

4.02

4.33

4.08

4.09

4.09

4.05

4.33

4.06

4.27

4.06

4.09

4.04

4.23

4.04

4.07

4.23

4.03

4.06

4.02

4.23

4.09

4.27

4.23

E

E

D

C

A

A

B

A

A

B

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

HeatingMH080FXEA4B

NoteSpecifications are subject to change without prior notice for product improvement.

NoteSpecifications are subject to change without prior notice for product improvement.

Page 31: DVM Catalog

Different types of air conditioners are required depending on different types of buildings andresidential space. Searching for the right air conditioner for your commercial and residentialspace is over. You’ll be able to find the one you need from Samsung’s variety of indoor units instyle. Perfect fit, just the way you need it.

Indoor Units

>> 62_ Wall-mounted Type >64_ MB >66_ Vivace >68_ Neo Forte >> 70_ Cassette Type >72_ Slim 1Way Cassette

>76_ 2Way Cassette >78_ Mini 4Way Cassette >80_ 4Way Cassette >> 84_ Duct Type >86_ Slim Duct >90_ MSP Duct

>> 92_ Floor & Convertible >94_ Console >98_ Ceiling >> 100_ ERV System >> 104_ Accessories

imaginethe perfect fit

60 61

Indoor Units

Indoor Units

Page 32: DVM Catalog

Indoor Units - Wall-mounted type

2008 SAMSUNG DVM Air Conditioners Indoor Units

62 63

Indoor Units

Wall-mounted typeAir conditionersSamsung’s brand new wall-mounted type air conditioners have more than just afeature of comfortable cooling. New wall-mounted air conditioners will be part ofyour interior design and protect your health with built-in health care system.Breathe cooler and healthier air every second of your life.

MPI Zone (Optional)

● Creation of an Intensely Purified Zone

● Protection against disease

● Safe from allergy-causing agents

● Controls active oxygen which can cause disease,cancer, and accelerated aging

Do you know that harmful substances andviruses breed in the space you live in?

How Micro Plasma Ion Systemtechnology Works

Health Care System 5-Step Air Purifying System

Micro Plasma Ion improves yourIndoor Air Quality and eliminatesall your worries.

Active hydrogen /Oxygen ions

Active hydrogen and oxygen ionsare generated

Harmful substancesCombines with

Harmful substancesOH radical, Harmfulviruses and bacteria.

Harmlesswater

Turns into harmless water

Health Care System (Optional)

Good’sleep II (MB/Forte)

Best Temperature for deep sleepAccording to the stage of sleep, temperatures are adjusted so you fall into deep sleep faster and get up morerefreshed in the morning for a great start to your day.

1. Falling asleep stage: Eases you into sleep by dropping the temperature.2. Sound sleep stage: Relaxes your body and raises your temperature slightly.3. Wake up stage: Allows you to wake up from comfortable intermittent air and it makes you feel refresh.

MPI Zone (Optional)

Stage 1

Stage 1 Auto Roof Shutter(MB)

Stage 3

Stage 2

Step 5

Deodorizing filterStep 4

DNA or Catechin FilterStep 3

Silver Coated Evaporator(Optional)

Step 2

Silver Coated FilterStep 1

The Samsung air conditioner is all what you needto keep your air consistently clean and fresh.

The Auto Roof Shutter keeps dirt from gettinginside.

Stage 2 MPI (Micro Plasma Ion )Biological contaminants and various pathogenssuch as bacteria, viruses, and molds are removed.

Stage 3 DNA filter & 5 step filterExogenous endocrine-disrupting chemicals, hazardous materials, and other harmful chemicals are removed.

Page 33: DVM Catalog

Indoor Units - Wall-mounted type

2008 SAMSUNG DVM Air Conditioners Indoor Units

64 65

Indoor Units

••• Unique and Innovative•••

MB

Blue Light Pearl Color Auto Roof Shutter

Auto Roof Shutter (2.8/3.6kW)This unique air conditioner automatically seals off to preventdirt infiltration when not in operation.

DNA FilterIt is a new technology that screens selectively for only toxicagents. This enables a smarter and effective air managementcompared to other filters.

MPI (Micro Plasma Ion)The world's first technology that generates active hydrogenatoms together with oxygen ions to improve your Indoor AirQuality. It protects you from harmful particles and virusesexisting in the air.

Good’sleep IIInnovative technology developed to control the air temperatureduring your sleep and maintain optimum skin temperature toenjoy a comfortable sleep and also a refreshed wake up.

Deodorizing filterIncorporated with activated carbon, the Deodorizing Filterefficiently adsorbscigarette smoke, pet odors and other unpleasant odors.

Design

Silver Coated EvaporatorThe fins of the evaporator are triple coated with environmen-tally friendly materials (2 years of chrome-free silica, 1 layer ofSilver coating) to ensure efficient removal of condensation andto guarantee the production of clean and fresh air.

OptionalAccessories

Individual Controllers

MR-BH01MWR-WS00

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.*6) Optional Accessory

Power Source

Mode *1)

Performance

power

Sound

Fan

Airflow Rate

Refrigerant

Piping

Connections

Weight

Set Size

Standard

Accessories

Capacity

Input

Running Current

Sound Pressure (High/Low) *4)

Type

Cooling (High)

Heating (High)

Type

Control Method

Liquid (Flare)

Gas (Flare)

Drain (Quick Lock)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Filter / Safety Grille

Wireless Remote Controller

Model

Ø/V/Hz

kW

Btu/h

kW

Btu/h

W

A

dB(A)

-

m3/min

m3/min

-

-

Ø,mm

Ø,mm

Ø,mm

kg

kg

mm

mm

-

-

AVXWBH028EE AVXWBH036EE AVXWBH056EE AVXWBH071EE

1/220~240/50

HP/HR

3.6

12,200

4.0

13,600

30

0.19

35 / 21 *5)

Cross Flow Fan

9.16 *5)

9.46 *5)

R410A

EEV *6)

6.35

12.70

ID 18 hose

10.2 *5)

11.5 *5)

900x304x185

963x349x247

Filter (Washable)

ARH-1364

1/220~240/50

HP/HR

5.6

19,100

6.3

21,400

50

0.3

40 / 30 *5)

Cross Flow Fan

14.98 *5)

14.49 *5)

R410A

EEV *6)

6.35

12.70

ID 18 hose

13.0 *5)

16.0 *5)

1,100x307x225

1,157x381x292

Filter (Washable)

ARH-1364

1/220~240/50

HP/HR

6.8

23,200

7.0

23,800

50

0.3

41 / 30 *5)

Cross Flow Fan

-

-

R410A

EEV *6)

9.52

15.88

ID 18 hose

13.0 *5)

16.0 *5)

1,100x307x225

1,157x381x292

Filter (Washable)

ARH-1364

1/220~240/50

HP/HR

2.8

9,500

3.2

10,900

30

0.18

31 / 20 *5)

Cross Flow Fan

8.14 *5)

8.23 *5)

R410A

EEV *6)

6.35

12.70

ID 18 hose

10.2 *5)

11.5 *5)

900x304x185

963x349x247

Filter (Washable)

ARH-1364

Cooling *2)

Heating *3)

Specification | MB

MWR-TH01 MWR-SH00

Page 34: DVM Catalog

Indoor Units - Wall-mounted type

2008 SAMSUNG DVM Air Conditioners Indoor Units

66 67

Indoor Units

••• Chic and Graceful•••

Vivace (Shadow Mirror)

Shadow Mirror Hidden Display Trim-less Design

MPI (Micro Plasma Ion)The world's first technology that generates active hydrogenatoms together with oxygen ions to improve your Indoor AirQuality. It protects you from harmful particles and virusesexisting in the air.

Good’sleep IIInnovative technology developed to control the air temperatureduring your sleep and maintain optimum skin temperature toenjoy a comfortable sleep and also a refreshed wake up.

Catechin filterCatechin, extracted from green tea, is contained in the filterand deactivates captured bacteria and unpleasant odors.

Deodorizing filterIncorporated with activated carbon, the Deodorizing Filterefficiently adsorbscigarette smoke, pet odors and other unpleasant odors.

Design

Silver Coated EvaporatorThe fins of the evaporator are triple coated with environmen-tally friendly materials (2 years of chrome-free silica, 1 layer ofSilver coating) to ensure efficient removal of condensation andto guarantee the production of clean and fresh air.

OptionalAccessories

Individual Controllers

Specification | Vivace

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.*6) Optional Accessory

Power Source

Mode *1)

Performance

power

Sound

Fan

Airflow Rate

Refrigerant

Piping

Connections

Weight

Set Size

Standard

Accessories

Capacity

Input

Running Current

Sound Pressure (High/Low) *4)

Type

Cooling (High)

Heating (High)

Type

Control Method

Liquid (Flare)

Gas (Flare)

Drain (Quick Lock)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Filter / Safety Grille

Wireless Remote Controller

Model

Ø/V/Hz

kW

Btu/h

kW

Btu/h

W

A

dB(A)

-

m3/min

m3/min

-

-

Ø,mm

Ø,mm

Ø,mm

kg

kg

mm

mm

-

-

AVXWVH022EE

1/220~240/50

HP/HR

2.2

7,500

2.5

8,500

30

0.13

31 / 21 *5)

Cross Flow Fan

8.82

6.11

R410A

EEV *6)

6.35

12.70

ID 18 hose

8.5

11.5

825x285x189

900x349x252

Filter (Washable)

ARH-1364

AVXWVH028EE

1/220~240/50

HP/HR

2.8

9,500

3.2

10,900

30

0.18

31 / 21

Cross Flow Fan

7.0

7.3

R410A

EEV *6)

6.35

12.70

ID 18 hose

8.5

11.5

825x285x189

900x349x252

Filter (Washable)

ARH-1364

AVXWVH036EE

1/220~240/50

HP/HR

3.6

12,200

4.0

13,600

35

0.19

35 / 21

Cross Flow Fan

8.2

8.8

R410A

EEV *6)

6.35

12.70

ID 18 hose

8.5

11.5

825x285x189

900x349x252

Filter (Washable)

ARH-1364

AVXWVH056EE

1/220~240/50

HP/HR

5.6

19,100

6.3

21,400

50

0.30

40 / 30

Cross Flow Fan

13.3

14.0

R410A

EEV *6)

6.35

12.70

ID 18 hose

12.0

15.0

1,065x298x218

1,137x377x299

Filter (Washable)

ARH-1364

AVXWVH071EE

1/220~240/50

HP/HR

6.8

23,200

7.0

23,800

50

0.30

41 / 30

Cross Flow Fan

13.3

14.0

R410A

EEV *6)

9.52

15.88

ID 18 hose

12.0

15.0

1,065x298x218

1,137x377x299

Filter (Washable)

ARH-1364

Cooling *2)

Heating *3)

MR-BH01MWR-WS00MWR-TH01 MWR-SH00

Page 35: DVM Catalog

Indoor Units - Wall-mounted type

2008 SAMSUNG DVM Air Conditioners Indoor Units

68 69

Indoor Units

Indoor Units

••• Clean and Fashionable•••

Neo Forte

Clean-Cut Front Panel Silver Accent Line Bottom Opening Front Panel

Good’sleep IIInnovative technology developed to control the air temperatureduring your sleep and maintain optimum skin temperature toenjoy a comfortable sleep and also a refreshed wake up.

Catechin filterCatechin, extracted from green tea, is contained in the filterand deactivates captured bacteria and unpleasant odors.

Deodorizing filterIncorporated with activated carbon, the Deodorizing Filterefficiently adsorbscigarette smoke, pet odors and other unpleasant odors.

Design

Silver Coated EvaporatorThe fins of the evaporator are triple coated with environmen-tally friendly materials (2 years of chrome-free silica, 1 layer ofSilver coating) to ensure efficient removal of condensation andto guarantee the production of clean and fresh air.

OptionalAccessories

Individual Controllers

Specification | Neo Forte

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.*6) Optional Accessory

Power Source

Mode *1)

Performance

power

Sound

Fan

Airflow Rate

Refrigerant

Piping

Connections

Weight

Set Size

Standard

Accessories

Capacity

Input

Running Current

Sound Pressure (High/Low) *4)

Type

Cooling (High)

Heating (High)

Type

Control Method

Liquid (Flare)

Gas (Flare)

Drain (Quick Lock)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Filter / Safety Grille

Wireless Remote Controller

Model

Ø/V/Hz

kW

Btu/h

kW

Btu/h

W

A

dB(A)

-

m3/min

m3/min

-

-

Ø/mm

Ø,mm

Ø,mm

kg

kg

mm

mm

-

-

AVXWNH022EE AVXWNH028EE AVXWNH036EE AVXWNH056EE AVXWNH071EE

1/220~240/50

HP/HR

2.8

9,500

3.2

10,900

25

0.16

32/23

Cross Flow Fan

8.31 *5)

8.56 *5)

R410A

EEV *6)

6.35

12.70

ID 18 hose

8.5 *5)

11.5 *5)

825x285x189

900x349x252

Filter (Washable)

ARH-1364

1/220~240/50

HP/HR

3.6

12,200

4.0

13,600

30

0.18

36/23 *5)

Cross Flow Fan

9.54 *5)

9.93 *5)

R410A

EEV *6)

6.35

12.70

ID 18 hose

8.5 *5)

11.5 *5)

825x285x189

900x349x252

Filter (Washable)

ARH-1364

1/220~240/50

HP/HR

5.6

19,100

6.3

21,400

45

0.27

40/30 *5)

Cross Flow Fan

13.21 *5)

14.22 *5)

R410A

EEV *6)

6.35

12.70

ID 18 hose

12.0 *5)

15.0 *5)

1,065x298x218

1,137x377x299

Filter (Washable)

ARH-1364

1/220~240/50

HP/HR

6.8

23,200

7.0

23,800

50

0.30

41/30 *5)

Cross Flow Fan

14.45 *5)

14.94 *5)

R410A

EEV *6)

9.52

15.88

ID 18 hose

12.0 *5)

15.0 *5)

1,065x298x218

1,137x377x299

Filter (Washable)

ARH-1364

1/220~240/50

HP/HR

2.2

7,500

2.5

8,500

25

0.16

32/23 *5)

Cross Flow Fan

7.73 *5)

8.00 *5)

R410A

EEV *6)

6.35

12.70

ID 18 hose

8.5 *5)

11.5 *5)

825x285x189

900x349x252

Filter (Washable)

ARH-1364

Cooling *2)

Heating *3)

MR-BH01MWR-WS00MWR-TH01 MWR-SH00

Page 36: DVM Catalog

Indoor Units - Cassette type

2008 SAMSUNG DVM Air Conditioners Indoor Units

70 71

Cassette typeAir conditionersThis year's new cassette type air conditioner still boasts its slim and compact size,but is now equipped with more advanced features. The cassette type air conditionernot only has stronger airflow to cool and heat every inch of space efficiently, but isalso designed to be quiet and to purify. Expect more with Samsung.

Cassette type Icon

WIDE BLADE

FRESH AIR INTAKE

SUB DUCTQUICK CONNECTION OF DRAIN PIPE

CEILING SOILINGPREVENTION

HIGH LIFT-UP DRAIN PUMPWIDEWIDEWIDEWIDE HIGHHIGHHIGHHIGH

FRESHFRESHFRESHFRESH SUB DUCTSUB DUCTSUB DUCTSUB DUCT QUICKQUICKQUICKQUICK

Wide BladeThe new cassette type air conditioner is equipped with uniquely designed blades that are wider to provide even cooling andheating power throughout the room.

WIDEWIDEWIDEWIDE

64mm

46mm

WIDER

Airflow is directed towards theceiling which cause ceilingsoiling.

Airflow is directed downwardswithout having contact with theceiling.

Ceiling Soiling PreventionNewly designed panel will control the air direction to avoid having contactwith the ceiling. This new design will prevent the ceiling soiling and keep yourinterior cleaner than ever even, after long period of operation.

Conventional Blade

Ceiling Ceiling

New Blade

600(mm) 650

Lift-up Range

700 750

750mm

700mm

High Lift-up Drain PumpThe lift-up drain pump lifts condensed water up to 750mm,compared to the competitor’s 700mm, allowing for flexibleand convenient installation.

Fresh Air IntakeWith optional installation of an air intake motor, fresh air canenter through the cassette unit so you have fresher air in theroom.

Sub DuctThe Sub Duct lets you use the same air conditioner unit tocool another smaller space nearby. (The cassette unit is fitted with a knock-out component to accommodate this.)

Quick Connection of Drain PipeSamsung's unique drain pipe prevents leaks and is easier toinstall with no need to use tape or adhesives.

FRESHFRESHFRESHFRESH

SUB DUCTSUB DUCTSUB DUCTSUB DUCT QUICKQUICKQUICKQUICK

HIGHHIGHHIGHHIGH

Company A

Fresh air

Office Fitting room

Motor

Samsung

Indoor Units

Page 37: DVM Catalog

2008 SAMSUNG DVM Air Conditioners Indoor Units

Indoor Units - Cassette type 72 73

Individual Controllers

Panel

PSSMA

OptionalAccessories

WIDE BLADEQUICK CONNECTION OF DRAIN PIPE

CEILING SOILINGPREVENTION

HIGH LIFT-UP DRAIN PUMPWIDEWIDEWIDEWIDE HIGHHIGHHIGHHIGH QUICKQUICKQUICKQUICK

Slim and Compact Design

Slim 1Way CassetteWant a cassette type air conditioner, but have limited space? Samsung's new Slim 1Way cassette type air conditioner is the answer.

10.5kg

17kg

38% Down

4kW R410A model Weight

Only 135mm thickSamsung introduces the world's slimmest indoorair conditioner unit. Only 135mm thick, the slim 1Way Cassette air conditioner can be installedpractically anywhere.

Lighter indoor unitThe first to apply ABS cabinets into its indoorunits, Samsung has achieved the lightest unitson the market. Its slim lightweight design makesinstallation and maintenance a breeze.

135mm

Ensure that there is sufficient installation space. Allow at least170mm for the installation.

NOTE

Min. 170mm

Quiet OperationSamsung's new blade design drastically reduces noise levels, so you can relax in peace and quiet.

25dB

35dB

30dB

43dB

Low

High

Fan speed Noise level

Check Valve Inside Drain PumpFaulty drainage installation or power failures can cause condensed water to flow back into the unit, causingleakage and odors. Samsung's air conditioners are equipped with a check valve built directly into the drainpump to prevent water from flowing backward.

Check Valve

••• Stylish and Slim •••

Slim 1Way Cassette

Indoor Units

MR-AH01MR-BH01MWR-WS00MWR-TH01 MWR-SH00

Page 38: DVM Catalog

2008 SAMSUNG DVM Air Conditioners Indoor Units

Indoor Units - Cassette type 74 75

Specification | Slim 1Way Cassette

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.

Indoor Units

Power Source

Mode *1)

Performance

power

Sound

Fan

Airflow Rate

Refrigerant

Piping

Connections

Weight

Set Size

Panel Size

Standard

Accessories

Capacity

Input

Running Current

Sound Pressure (High/Low) *4)

Type

Cooling (High)

Heating (High)

Type

Control Method

Liquid (Flare)

Gas (Flare)

Drain (Quick Lock)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Model

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Filter / Safety Grille

Drain Pump (Pumping speed / lift)

AVXCSH022EEModel

Ø/V/Hz

kW

Btu/h

kW

Btu/h

W

A

dB(A)

-

m3/min

m3/min

-

-

Ø,mm

Ø,mm

Ø,mm

kg

kg

mm

mm

-

kg

kg

mm

mm

-

l/h /mm

1/220~240/50

HP/HR

2.2

7,500

2.5

8,500

40

0.20

30/25 *5)

Cross Flow Fan

5.4 *5)

7.6 *5)

R410A

EEV

6.35

12.70

VP20(OD 25,ID 20)

10.5

13.5

970x135x410

1,164x212x478

PSSMA

3.0

5.0

1,180x25x460

1,259x144x539

Filter (Washable)

24/750

Cooling *2)

Heating *3)

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.

Power Source

Mode *1)

Performance

power

Sound

Fan

Airflow Rate

Refrigerant

Piping

Connections

Weight

Set Size

Panel Size

Standard

Accessories

Capacity

Input

Running Current

Sound Pressure (High/Low) *4)

Type

Cooling (High)

Heating (High)

Type

Control Method

Liquid (Flare)

Gas (Flare)

Drain (Quick Lock)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Model

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Filter / Safety Grille

Drain Pump (Pumping speed / lift)

AVXCSH028EEModel

Ø/V/Hz

kW

Btu/h

kW

Btu/h

W

A

dB(A)

-

m3/min

m3/min

-

-

Ø,mm

Ø,mm

Ø,mm

kg

kg

mm

mm

-

kg

kg

mm

mm

-

l/h /mm

1/220~240/50

HP/HR

2.8

9,500

3.2

10,900

45

0.23

30 / 25 *5)

Cross Flow fan

6.0 *5)

8.6 *5)

R410A

EEV

6.35

12.70

VP20(OD 25,ID 20)

10.5

13.5

970x135x410

1,164x212x478

PSSMA

3.0

5.0

1,180x25x460

1,259x144x539

Filter (Washable)

24/750

AVXCSH036EE

1/220~240/50

HP/HR

3.6

12,200

4.0

13,600

50.5

0.25

32 / 27 *5)

Cross Flow fan

7.5 *5)

9.7 *5)

R410A

EEV

6.35

12.70

VP20(OD 25,ID 20)

10.5

13.5

970x135x410

1,164x212x478

PSSMA

3.0

5.0

1180x25x460

1259x144x539

Filter (Washable)

24/750

Cooling *2)

Heating *3)

Page 39: DVM Catalog

2008 SAMSUNG DVM Air Conditioners Indoor Units

Indoor Units - Cassette type 76 77

Individual Controllers

PanelOptionalAccessories

••• Slim and Compact •••

2Way CassetteSpecification | 2Way Cassette

QUICK CONNECTION OF DRAIN PIPE

HIGH LIFT-UP DRAIN PUMPHIGHHIGHHIGHHIGH QUICKQUICKQUICKQUICK

Small Size Big PerformanceThe 2Way cassette air conditioner is now 45% smaller thancompetitor’s models, so it's even easier to incorporate intobuilding design.

Twin Cross Flow FanThe 2Way cassette type unit is perfect fit for long and narrowrectangular type of space. Twin Cross Flow Fan inside of the2Way cassette will spread cool or warm air even further andwider with less noise.

Standard Formula for Easy InstallationThe dimensions of the 2Way cassette air conditioner allows for easyinstallation into standard ceiling grids (600Wx600H), so everythingjust falls into place.

230mm

890mm575mm

45%Decreased

305mm

1,180mm600mm

P2SMA

Indoor Units

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.

Power Source

Mode *1)

Performance

power

Sound

Fan

Airflow Rate

Refrigerant

Piping

Connections

Weight

Set Size

Panel Size

Standard

Accessories

Capacity

Input

Running Current

Sound Pressure (High/Low) *4)

Type

Cooling (High)

Heating (High)

Type

Control Method

Liquid (Flare)

Gas (Flare)

Drain (Quick Lock)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Model

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Filter / Safety Grille

Drain Pump (Pumping speed / lift)

AVXC2H056EEModel

Ø/V/Hz

kW

Btu/h

kW

Btu/h

W

A

dB(A)

-

m3/min

m3/min

-

-

Ø,mm

Ø,mm

Ø,mm

kg

kg

mm

mm

-

kg

kg

mm

mm

-

l/h /mm

1/220~240/50

HP/HR

5.6

19,100

6.3

21,400

70

0.38

36 / 28

Cross Flow Fan

14.0

16.0

R410A

EEV

6.35

12.70

VP25 (OD 32,ID 25)

21.0

25.0

890x230x575

1,077x299x642

P2SMA

4.0

8.0

1,030x25x650

1,103x151x727

Filter (Washable)

24/750

AVXC2H071EE

1/220~240/50

HP/HR

7.1

24,200

8.0

27,200

75

0.40

38 / 28

Cross Flow Fan

14.0

16.0

R410A

EEV

9.52

15.88

VP25 (OD 32,ID 25)

21.0

25.0

890x230x575

1,077x299x642

P2SMA

4.0

8.0

1,030x25x650

1,103x151x727

Filter (Washable)

24/750

Cooling *2)

Heating *3)

MR-AH01MR-BH01MWR-WS00MWR-TH01 MWR-SH00

600mm

600mm

Cross flow fans

Page 40: DVM Catalog

2008 SAMSUNG DVM Air Conditioners Indoor Units

Indoor Units - Cassette type 78 79

Individual Controllers

OptionalAccessories

••• Compact and Efficient •••

Mini 4Way Cassette

FRESH AIR INTAKE

QUICK CONNECTION OF DRAIN PIPE

HIGH LIFT-UP DRAIN PUMPHIGHHIGHHIGHHIGH FRESHFRESHFRESHFRESH QUICKQUICKQUICKQUICK

Fan Speed AdjustmentFan speed can be adjusted according to ceiling height byadjusting dip switch of indoor unit’s PCB.

Ideal Compact SizeThe Mini 4Way cassette air conditioner can be installed in one standardceiling tile (600Wx600H), which can save installation time.

3~3.5m 2.7m

High Ceiling

On : Increased fan speed Off : Standard fan speed

Unit : mm

Standard Ceiling

Specification | Mini 4Way Cassette

PMSMA

Indoor Units

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.

Power Source

Mode *1)

Performance

power

Sound

Fan

Airflow Rate

Refrigerant

Piping

Connections

Weight

Set Size

Panel Size

Standard

Accessories

Capacity

Input

Running Current

Sound Pressure (High/Low) *4)

Type

Cooling (High)

Heating (High)

Type

Control Method

Liquid (Flare)

Gas (Flare)

Drain (Quick Lock)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Model

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Filter / Safety Grille

Drain Pump (Pumping speed / lift)

AVXCMH028EEModel

Ø/V/Hz

kW

Btu/h

kW

Btu/h

W

A

dB(A)

-

m3/min

m3/min

-

-

Ø,mm

Ø,mm

Ø,mm

kg

kg

mm

mm

-

kg

kg

mm

mm

-

l/h /mm

1/220~240/50

HP/HR

2.8

9,500

3.2

10,900

90

0.50

30 / 25

Turbo Fan

10.1

11.9

R410A

EEV

6.35

12.70

VP25 (OD 32,ID 25)

17.0

20.0

575x260x575

660x310x635

PMSMA

3.5

6.2

670x35x670

717x93x717

Filter / Safety Grille

24/750

AVXCMH036EE

1/220~240/50

HP/HR

3.6

12,200

4.0

13,600

90

0.50

34 / 27

Turbo Fan

10.1

11.9

R410A

EEV

6.35

12.70

VP25 (OD 32,ID 25)

17.0

20.0

575x260x575

660x310x635

PMSMA

3.5

6.2

670x35x670

717x93x717

Filter / Safety Grille

24/750

AVXCMH056EE

1/220~240/50

HP/HR

5.6

19,100

6.3

21,400

95

0.52

41 / 33

Turbo Fan

10.6

12.6

R410A

EEV

6.35

12.70

VP25 (OD 32,ID 25)

17.0

20.0

575x260x575

660x310x635

PMSMA

3.5

6.2

670x35x670

717x93x717

Filter / Safety Grille

24/750

AVXCMH060EE

1/220~240/50

HP/HR

6.0

20,400

6.8

23,200

100

0.55

41 / 33

Turbo Fan

12.2

14.5

R410A

EEV

6.35

12.70

VP25 (OD 32,ID 25)

17.0

20.0

575x260x575

660x310x635

PMSMA

3.5

6.2

670x35x670

717x93x717

Filter / Safety Grille

24/750

Cooling *2)

Heating *3)

MR-AH01MR-BH01MWR-WS00MWR-TH01 MWR-SH00

Panel

Page 41: DVM Catalog

2008 SAMSUNG DVM Air Conditioners Indoor Units

Indoor Units - Cassette type 80 81

New Turbo Fan

Stylish Panel DesignThe stylish panel is well harmonized with any interior design.

WIDE BLADE

FRESH AIR INTAKE

SUB DUCTQUICK CONNECTION OF DRAIN PIPE

CEILING SOILINGPREVENTION

HIGH LIFT-UP DRAIN PUMPWIDEWIDEWIDEWIDE HIGHHIGHHIGHHIGH

FRESHFRESHFRESHFRESH SUB DUCTSUB DUCTSUB DUCTSUB DUCT QUICKQUICKQUICKQUICK

Individual Controllers

PanelOptionalAccessories

Quiet OperationImagine a room of cool calmness. The aerodynamicallydesigned ‘Turbo Fan' minimizes noise from the turbulence of blade movement. Therefore noise isless than conventional models.

Uniform DistributionThe new 'Turbo Fan' with wide blades providesextreme cooling and heating power from 4 separate outlets so the entire room gets cool orwarm faster. Now, every nook and cranny is comfortable.

Easy LevelingEach corner portion of the panel is detachable, which gives easieraccess to adjust the height, therefore leveling and installation ismuch easier and quicker than before.

Compact SizeThe 4Way cassette type unit has gotten even slimmer. Nowonly 218mm thick (5.2/7.0/9.0kW), 24% slimmer compare tocompetitor’s 288mm (9.0kW). It's still the industry leader in compactness and is even easier to install in tight spaces.

Efficient Cooling3-dimensional blade, which has the world wide patent, is able to spread cool or warm air further and evenly toall corners of the space.

Conventional 4Way

Conventional 4Way

New 4Way

New 4Way

‘A’ View

‘B’ View

‘C’ View

Detachable corners make installationand height adjustments much easier.

Air distribution

Detaching the whole panel tookmore time.

218mm

••• Powerful and Silent •••

4Way Cassette

P4SMA

Indoor Units

Air distribution

MR-AH01MR-BH01MWR-WS00MWR-TH01 MWR-SH00

Outlet1

Outlet2

Outlet3

Outlet4

Page 42: DVM Catalog

2008 SAMSUNG DVM Air Conditioners Indoor Units

Indoor Units - Cassette type 82 83

Specification | 4Way Cassette

Indoor Units

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.

Power Source

Mode *1)

Performance

power

Sound

Fan

Airflow Rate

Refrigerant

Piping

Connections

Weight

Set Size

Panel Size

Standard

Accessories

Capacity

Input

Running Current

Sound Pressure (High/Low) *4)

Type

Cooling (High)

Heating (High)

Type

Control Method

Liquid (Flare)

Gas (Flare)

Drain (Quick Lock)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Model

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Filter / Safety Grille

Drain Pump (Pumping speed / lift)

AVXC4H045EEModel

Ø/V/Hz

kW

Btu/h

kW

Btu/h

W

A

dB(A)

-

m3/min

m3/min

-

-

Ø,mm

Ø,mm

Ø,mm

kg

kg

mm

mm

-

kg

kg

mm

mm

-

l/h /mm

1/220~240/50

HP/HR

4.5

15,300

5.0

17,000

40

0.19

34/29

Turbo Fan

14.5

16.5

R410A

EEV

6.35

12.70

VP25 (OD 32,ID 25)

25.0

31.0

840x218x840

926x280x926

P4SMA

7.0

10.3

950x35x950

1,042x103x1,042

Filter / Safety Grille

24/750

AVXC4H056EE

1/220~240/50

HP/HR

5.6

19,100

6.3

21,400

40

0.19

34/29

Turbo Fan

14.5

16.5

R410A

EEV

6.35

12.70

VP25 (OD 32,ID 25)

25.0

31.0

840x218x840

926x280x926

P4SMA

7.0

10.3

950x35x950

1,042x103x1,042

Filter / Safety Grille

24/750

AVXC4H071EE

1/220~240/50

HP/HR

7.1

24,200

8.0

27,200

45

0.21

36/30

Turbo Fan

17.0

18.5

R410A

EEV

9.52

15.88

VP25 (OD 32,ID 25)

25.0

31.0

840x218x840

926x280x926

P4SMA

7.0

10.3

950x35x950

1,042x103x1,042

Filter / Safety Grille

24/750

AVXC4H090EE

1/220~240/50

HP/HR

9.0

30,700

10.0

34,100

50

0.23

39/32

Turbo Fan

19.5

21.5

R410A

EEV

9.52

15.88

VP25 (OD 32,ID 25)

25.0

31.0

840x218x840

926x280x926

P4SMA

7.0

10.3

950x35x950

1,042x103x1,042

Filter / Safety Grille

24/750

Cooling *2)

Heating *3)

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.

Power Source

Mode *1)

Performance

power

Sound

Fan

Airflow Rate

Refrigerant

Piping

Connections

Weight

Set Size

Panel Size

Standard

Accessories

Capacity

Input

Running Current

Sound Pressure (High/Low) *4)

Type

Cooling (High)

Heating (High)

Type

Control Method

Liquid (Flare)

Gas (Flare)

Drain (Quick Lock)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Model

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Filter / Safety Grille

Drain Pump (Pumping speed / lift)

Model

Ø/V/Hz

kW

Btu/h

kW

Btu/h

W

A

dB(A)

-

m3/min

m3/min

-

-

Ø,mm

Ø,mm

Ø,mm

kg

kg

mm

mm

-

kg

kg

mm

mm

-

l/h /mm

AVXC4H112EE AVXC4H128EE AVXC4H140EE

1/220~240/50

HP/HR

11.2

38,200

12.5

42,600

50

0.23

40 / 33

Turbo Fan

23.0

26.5

R410A

EEV

9.52

15.88

VP25 (OD 32,ID 25)

29.0

35.0

840x298x840

926x360x926

P4SMA

7.0

10.3

950x35x950

1,042x103x1,042

Filter / Safety Grille

24/750

1/220~240/50

HP/HR

12.8

43,600

13.8

47,000

65

0.30

41 / 35

Turbo Fan

25.0

29.5

R410A

EEV

9.52

15.88

VP25 (OD 32,ID 25)

29.0

35.0

840x298x840

926x360x926

P4SMA

7.0

10.3

950x35x950

1,042x103x1,042

Filter / Safety Grille

24/750

1/220~240/50

HP/HR

14.0

47,700

16.0

54,500

80

0.36

45 / 38

Turbo Fan

26.5

32.0

R410A

EEV

9.52

15.88

VP25 (OD 32,ID 25)

29.0

35.0

840x298x840

926x360x926

P4SMA

7.0

10.3

950x35x950

1,042x103x1,042

Filter / Safety Grille

24/750

Cooling *2)

Heating *3)

Page 43: DVM Catalog

Indoor Units - Duct type

2008 SAMSUNG DVM Air Conditioners Indoor Units

84 85

Duct typeAir conditionersSamsung's new duct type air conditioners offer flexible installation benefits with its slim,compact size and the option to set up the air inlet either on the bottom or rear of theunit. Its Smart Pressure Control System also provides consistent cool and warm airregardless of the surrounding environment, and the filtering options give you cleaner,healthier air. Enjoy more with Samsung.

Duct type Icon

ANTI-BACTERIA FILTERBACTERIABACTERIABACTERIABACTERIA

EASY FILTER CLEANING

HIGH LIFT-UP DRAIN PUMPHIGHHIGHHIGHHIGH

SMART PRESSURECONTROL

Clean Filter SystemThe anti-bacteria filter and the filter cleaning indicator provide you with cleaner, healthier air. You deserve to breathe fresh air everyday.

Anti-bacteria FilterThe anti-bacteria filter not only traps dust particles, butsuppresses proliferation of molds and bacteria.

BACTERIABACTERIABACTERIABACTERIA Easy Filter CleaningAfter 1,000 hours of operation the filter clean indicatorwill inform you that the filter should be cleaned. The filter can be easily removed from the bottom, left, or rightof the unit. (1,000 hours is the default set time, whichcan be adjusted to 2,000 hours on the internal PCB.)

High Lift-up Drain Pump (optional)The lift-up drain pump lifts condensed water up to 750mm, compared to the competitor’s 700mm, allowing for flexible and convenient installation.

HIGHHIGHHIGHHIGH

Smart Pressure ControlThe Smart Pressure Control System adjusts fan speed according toE.S.P(External Static Pressure), so the air conditioner always givesyou consistent cooling and heating power regardless of the surrounding environment.

E.S.P Control

Air v

olum

e

Static pressure (mmAq)Minimum Maximum

H

H

M

M

L

L

Air volume 1mmAq Air volume 3mmAq

Indoor Units

Page 44: DVM Catalog

Slim DesignOnly 199mm thick, this slim design makes installation, maintenance,and repair easy.

Easy to MaintainParts are easily accessible by simply opening the bottompanel, which reduces time and maintenance costs.

199mm

••• Slim and Flexible •••

Slim Duct

Indoor Units - Duct type

2008 SAMSUNG DVM Air Conditioners Indoor Units

86 87

Indoor Units

ANTI-BACTERIA FILTERBACTERIABACTERIABACTERIABACTERIA

EASY FILTER CLEANING

HIGH LIFT-UP DRAIN PUMPHIGHHIGHHIGHHIGH

SMART PRESSURECONTROL

Flexible InstallationThe air inlet can be set up on either the bottom or rearof the unit, so there is more flexibility in installation.

Individual Controllers

OptionalAccessories

Specification | Slim Duct type

Drain Pump

MDP-E075SEE / MDP-E075SEE1

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.

Power Source

Mode *1)

Performance

power

Sound

Fan

Airflow Rate

Refrigerant

Piping

Connections

Weight

Set Size

Standard

Accessories

Optional

Accessories

Capacity

Input

Running Current

Sound Pressure (High/Low) *4)

Type

Cooling (High)

Heating (High)

External Static Pressure

Type

Control Method

Liquid (Flare)

Gas (Flare)

Drain

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Filter / Safety Grille

Duct Receiver Kits

Drain Pump

Model

Ø/V/Hz

kW

Btu/h

kW

Btu/h

W

A

dB(A)

-

m3/min

m3/min

mmAq

-

-

Ø,mm

Ø,mm

Ø,mm

kg

kg

mm

mm

-

-

-

-

Cooling *2)

Heating *3)

Standard(Min.~Max.)

Receiver

Receiver Wire

AVXDSH022EE

1/220~240/50

HP/HR

2.2

7,500

2.5

8,500

80

0.40

31 / 26

Sirocco Fan

8.0

9.0

2 (0~4)

R410A

EEV

6.35

12.70

VP25 (OD 32,ID 25)

26.0

31.0

900x199x600

1,133x333x722

Filter (Washable)

MRK-A00

MRW-10A

MDP-E075SEE

AVXDSH028EE

1/220~240/50

HP/HR

2.8

9,500

3.2

10,900

80

0.40

32 / 27

Sirocco Fan

9.0

10.0

2 (0~4)

R410A

EEV

6.35

12.70

VP25 (OD 32,ID 25)

26.0

31.0

900x199x600

1,133x333x722

Filter (Washable)

MRK-A00

MRW-10A

MDP-E075SEE

AVXDSH036EE

1/220~240/50

HP/HR

3.6

12,200

4.0

13,600

80

0.40

32 / 27

Sirocco Fan

10.0

12.0

2 (0~4)

R410A

EEV

6.35

12.70

VP25 (OD 32,ID 25)

26.0

31.0

900x199x600

1,133x333x722

Filter (Washable)

MRK-A00

MRW-10A

MDP-E075SEE

MR-AH01MR-BH01MWR-WS00MWR-TH01 MWR-SH00

Rear side air inlet Bottom side air inlet

Suction DuctSuction Duct

TexTexDiffuser

Diffuser

199mm

220mm

225mm

160 180 200 220210 230

Page 45: DVM Catalog

Indoor Units - Duct type

2008 SAMSUNG DVM Air Conditioners Indoor Units

88 89

Indoor Units

Specification | Slim Duct type

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.

Power Source

Mode *1)

Performance

power

Sound

Fan

Airflow Rate

Refrigerant

Piping

Connections

Weight

Set Size

Standard

Accessories

Optional

Accessories

Capacity

Input

Running Current

Sound Pressure (High/Low) *4)

Type

Cooling (High)

Heating (High)

External Static Pressure

Type

Control Method

Liquid (Flare)

Gas (Flare)

Drain

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Filter / Safety Grille

Duct Receiver Kits

Drain Pump

Model

Ø/V/Hz

kW

Btu/h

kW

Btu/h

W

A

dB(A)

-

m3/min

m3/min

mmAq

-

-

Ø,mm

Ø,mm

Ø,mm

kg

kg

mm

mm

-

-

-

-

Cooling *2)

Heating *3)

Standard(Min.~Max.)

Receiver

Receiver Wire

AVXDSH045EE

1/220~240/50

HP/HR

4.5

15,300

5.0

17,000

90

0.60

33 / 30

Sirocco Fan

14.5

16.5

2 (0~4)

R410A

EEV

6.35

12.70

VP25 (OD 32,ID 25)

31.0

39.0

1,100x199x600

1,330x330x730

Filter (Washable)

MRK-A00

MRW-10A

MDP-E075SEE

AVXDSH056EE

1/220~240/50

HP/HR

5.6

19,100

6.3

21,400

100

0.60

33 / 30

Sirocco Fan

15.5

18.0

2 (0~4)

R410A

EEV

6.35

12.70

VP25 (OD 32,ID 25)

31.0

39.0

1,100x199x600

1,330x330x730

Filter (Washable)

MRK-A00

MRW-10A

MDP-E075SEE

AVXDSH071EE

1/220~240/50

HP/HR

7.1

24,200

8.0

27,200

120

0.60

36 / 32

Sirocco Fan

16.5

20.0

2 (0~4)

R410A

EEV

9.52

15.88

VP25 (OD 32,ID 25)

31.0

39.0

1,100x199x600

1,330x330x730

Filter (Washable)

MRK-A00

MRW-10A

MDP-E075SEE

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.

Power Source

Mode *1)

Performance

power

Sound

Fan

Airflow Rate

Refrigerant

Piping

Connections

Weight

Set Size

Standard

Accessories

Optional

Accessories

Capacity

Input

Running Current

Sound Pressure (High/Low) *4)

Type

Cooling (High)

Heating (High)

External Static Pressure

Type

Control Method

Liquid (Flare)

Gas (Flare)

Drain

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Filter / Safety Grille

Duct Receiver Kits

Drain Pump

Model

Ø/V/Hz

kW

Btu/h

kW

Btu/h

W

A

dB(A)

-

m3/min

m3/min

mmAq

-

-

Ø,mm

Ø,mm

Ø,mm

kg

kg

mm

mm

-

-

-

-

Cooling *2)

Heating *3)

Standard(Min.~Max.)

Receiver

Receiver Wire

AVXDSH090EE

1/220~240/50

HP/HR

9.0

30,700

10.0

34,100

170

0.96

40 / 36

Sirocco Fan

29.0

34.0

3 (0-6)

R410A

EEV

9.52

15.88

VP25 (OD 32,ID 25)

43.0

51.5

1,300x295x690

1,600x444x831

Filter (Washable)

MRK-A00

MRW-10A

MDP-E075SEE1

AVXDSH112EE

1/220~240/50

HP/HR

11.2

38,200

12.5

42,600

170

0.96

40 / 36

Sirocco Fan

31.2

34.0

3 (0~6)

R410A

EEV

9.52

15.88

VP25 (OD 32,ID 25)

43.0

51.5

1,300x295x690

1,600x444x831

Filter (Washable)

MRK-A00

MRW-10A

MDP-E075SEE1

AVXDSH128EE

1/220~240/50

HP/HR

12.8

43,600

13.8

47,000

200

1.13

41 / 38

Sirocco Fan

34.0

36.0

3 (0~6)

R410A

EEV

9.52

15.88

VP25 (OD 32,ID 25)

46.0

54.5

1,300x295x690

1,600x444x831

Filter (Washable)

MRK-A00

MRW-10A

MDP-E075SEE1

AVXDSH140EE

1/220~240/50

HP/HR

14.0

47,700

16.0

54,500

220

1.24

41 / 38

Sirocco Fan

36.0

38.0

3 (0~6)

R410A

EEV

9.52

15.88

VP25 (OD 32,ID 25)

46.0

54.5

1,300x295x690

1,600x444x831

Filter (Washable)

MRK-A00

MRW-10A

MDP-E075SEE1

Page 46: DVM Catalog

••• Flexible and Silent•••

MSP Duct

Indoor Units - Duct type

2008 SAMSUNG DVM Air Conditioners Indoor Units

90 91

Indoor Units

Individual Controllers

OptionalAccessories

Specification | MSP Duct type

Drain Pump

Easy to MaintainReduce time and maintenance costs by keeping parts easilyaccessible.

Flexible InstallationSamsung's MSP Duct air conditioners offer different solutionsfor any shape room allowing for specific airflow requirements.

L-shaped area Y-shaped areaAreas far apart

Silent Operation with the static pressure controlThe external static pressure control makes it easy to design duct work to ensure efficiency and silent operation.

Narrow Width (5.6kW) Middle Static Pressure

900mmSlim Duct

mmAq

2

4

6

8

10

MSP Duct

0~10mmAq

0~6mmAq

ANTI-BACTERIA FILTERBACTERIABACTERIABACTERIABACTERIA

EASY FILTER CLEANING

HIGH LIFT-UP DRAIN PUMPHIGHHIGHHIGHHIGH

SMART PRESSURECONTROL

WIRED REMOTE CONTROLLERWiredWiredWiredWired

MDP-M075SGU1 / MDP-M075SGU2 /MDP-M075SGU3

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.

Power Source

Mode *1)

Performance

power

Sound

Fan

Airflow Rate

Refrigerant

Piping

Connections

Weight

Set Size

Standard

Accessories

Optional

Accessories

Capacity

Input

Running Current

Sound Pressure (High/Low) *4)

Type

Cooling (High)

Heating (High)

External Static Pressure

Type

Control Method

Liquid (Flare)

Gas (Flare)

Drain

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Filter / Safety Grille

Duct Receiver Kits

Drain Pump

Model

Ø/V/Hz

kW

Btu/h

kW

Btu/h

W

A

dB(A)

-

m3/min

m3/min

mmAq

-

-

Ø,mm

Ø,mm

Ø,mm

kg

kg

mm

mm

-

-

-

-

Cooling *2)

Heating *3)

Standard(Min.~Max.)

Receiver

Receiver Wire

AVXDUH056EE

1/220~240/50

HP/HR

5.6

19,100

6.3

21,400

240*5)

1.2*5)

39 / 35

Sirocco Fan

14.5

15.5

4 (0~6)

R410A

EEV

6.35

12.70

VP25 (OD 32,ID 25)

31.0

36.0

900x260x480

1,146x345x584

Filter

(Washable)

MRK-A00

MRW-10A

MDP-M075SGU3

AVXDUH071EE

1/220~240/50

HP/HR

7.1

24,200

8.0

27,200

240*5)

1.2*5)

39 / 35

Sirocco Fan

18.5

20.0

4 (0~6)

R410A

EEV

9.52

15.88

VP25 (OD 32,ID 25)

31.0

36.0

900x260x480

1,146x345x584

Filter

(Washable)

MRK-A00

MRW-10A

MDP-M075SGU3

AVXDUH112EE

1/220~240/50

HP/HR

11.2

38,200

12.5

42,600

260

1.17

39 / 35

Sirocco Fan

27.0

27.0

8 (6~10)

R410A

EEV

9.52

15.88

VP25 (OD 32,ID 25)

39.0

46.0

1,150x320x480

1,390x420x584

Filter

(Washable)

MRK-A00

MRW-10A

MDP-M075SGU1

AVXDUH090EE

1/220~240/50

HP/HR

9.0

30,700

10.0

34,100

240*5)

1.2*5)

39 / 35

Sirocco Fan

19.5

21.5

6 (4~8)

R410A

EEV

9.52

15.88

VP25 (OD 32,ID 25)

35.0

41.0

1,150x260x480

1,390x345x584

Filter

(Washable)

MRK-A00

MRW-10A

MDP-M075SGU1

AVXDUH128EE

1/220~240/50

HP/HR

12.8

43,600

13.8

47,000

370

1.67

39 / 35

Sirocco Fan

32.0

31.0

8 (6~10)

R410A

EEV

9.52

15.88

VP25 (OD 32,ID 25)

52.0

60.0

1,200x360x650

1,447x425x769

Filter

(Washable)

MRK-A00

MRW-10A

MDP-M075SGU2

AVXDUH140EE

1/220~240/50

HP/HR

14.0

47,700

16.0

54,500

410

1.86

43 / 38

Sirocco Fan

37.0

36.0

8 (6~10)

R410A

EEV

9.52

15.88

VP25 (OD 32,ID 25)

52.0

60.0

1,200x360x650

1,447x425x769

Filter

(Washable)

MRK-A00

MRW-10A

MDP-M075SGU2

❊ Width measured without control box.

MR-AH01MR-BH01MWR-WS00MWR-TH01 MWR-SH00

Page 47: DVM Catalog

Indoor Units - Floor & Convertible type

2008 SAMSUNG DVM Air Conditioners Indoor Units

92 93

Indoor Units

Floor & Convertible typeAir conditionersSamsung introduces a new elegance in air conditioners. This year's new console andceiling type air conditioners have the style to complement any decor. The flexibility ofdrain pipe placement also gives you more options in where you want to place the airconditioner. Staying cool has never been more stylish.

Floor & Convertible type Icon

INTERIORDESIGNINTERIORINTERIOR

DESIGNDESIGNINTERIORINTERIORDESIGNDESIGN

ANTI-BACTERIA FILTERBACTERIABACTERIABACTERIABACTERIA

LIGHT WEIGHT UNIT

LIGHTLIGHTLIGHTLIGHT

SILENTMODE

FLEXIBLE PIPE INSTALLATIONFlexible PipeFlexible Pipe

InstallationInstallationFlexible PipeFlexible PipeInstallationInstallation

WIRELESS REMOTECONTROLWirelessWirelessWirelessWireless

I Interior DesignNow with more flexibility in placement, the air conditionercan add a stylish element to your room.

INTERIORINTERIORDESIGNDESIGN

INTERIORINTERIORDESIGNDESIGN

Silent ModeIndoor units operate quietly with the least possible noise.

Anti-bacteria FilterThe anti-bacteria filter not only traps dust particles, butsuppresses proliferation of molds and bacteria.

BACTERIABACTERIABACTERIABACTERIA

Light Weight UnitThis extremely lightweight design makes maintenanceand installation easy.

LIGHTLIGHTLIGHTLIGHT

Flexible Pipe InstallationThe drain pipe can be installed in 6 different places, so youhave more options in where to place your air conditioner.

Flexible PipeFlexible PipeInstallationInstallationFlexible PipeFlexible PipeInstallationInstallation

Page 48: DVM Catalog

Indoor Units - Floor & Convertible type

2008 SAMSUNG DVM Air Conditioners Indoor Units

94 95

Indoor Units

OptionalAccessories

Elegant Design

••• Slim and Elegant •••

Console

INTERIORDESIGNINTERIORINTERIOR

DESIGNDESIGNINTERIORINTERIORDESIGNDESIGN

ANTI-BACTERIA FILTERBACTERIABACTERIABACTERIABACTERIA

LIGHT WEIGHT UNIT

LIGHTLIGHTLIGHTLIGHT

SILENT MODEFLEXIBLE PIPEINSTALLATIONFlexible PipeFlexible Pipe

InstallationInstallationFlexible PipeFlexible PipeInstallationInstallation

Individual Controllers

MWR-WS00

Clean PanelStay clean with the smartly designed Clean Panel. This uniquepanel keeps dust from being accumulated so the unit and theroom stays cleaner.

Slim DesignIt can't get any slimmer. This newly introduced console type airconditioner is only 199mm thick, the slimmest on the market.Its slim design easily integrates the unit into your decor.

Silent Operation (23dB)The silent, yet powerful and efficient cooling and heating system keeps things morecomfortable. Silent mode is available in 4 different operating modes: High / Medium /Low / Silence.

2Way air outletsThere are two separate air outlets for cooling and heating. Having warmer air comingout from the bottom part of the air outlet will spread the warm air evenly throughout theroom. Stay cooler and warmer in every corner of your room.

Slim & Smart DesignThis extremely slim design with Clean Panel adds aesthetic value to any interior.

199mm

Black DisplayFunctional art, the touch screen display is elegant while itmaximizes the convenience of control.

MWR-TH01

WIRELESS REMOTECONTROLWirelessWirelessWirelessWireless

MWR-SH00 ARH-1379

Page 49: DVM Catalog

2008 SAMSUNG DVM Air Conditioners Indoor Units

Indoor Units - Floor & Convertible type 96 97

Specification | Console

Indoor Units

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.

Power Source

Mode *1)

Performance

power

Sound

Fan

Airflow Rate

Refrigerant

Piping

Connections

Weight

Set Size

Standard

Accessories

Capacity

Input

Running Current

Sound Pressure (High/Low) *4)

Type

Cooling (High)

Heating (High)

Type

Control Method

Liquid (Flare)

Gas (Flare)

Drain (Quick Lock)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Filter / Safety Grille

Wireless Remote Controller

Model

Ø/V/Hz

kW

Btu/h

kW

Btu/h

W

A

dB(A)

-

m3/min

m3/min

-

-

Ø,mm

Ø,mm

Ø,mm

kg

kg

mm

mm

-

-

AVXTJH028EE

1/220~240/50

HP/HR

2.8

9,500

3.2

10,900

30

0.25

38 / 23 *5)

Turbo Fan

7.8*5)

7.2*5)

R410a

EEV

6.35

12.70

ID 18 hose

15.0

19.0

720x620x199

810x710x295

Filter (Washable)

AHR-1379

Cooling *2)

Heating *3)

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.

Power Source

Mode *1)

Performance

power

Sound

Fan

Airflow Rate

Refrigerant

Piping

Connections

Weight

Set Size

Standard

Accessories

Capacity

Input

Running Current

Sound Pressure (High/Low) *4)

Type

Cooling (High)

Heating (High)

Type

Control Method

Liquid (Flare)

Gas (Flare)

Drain (Quick Lock)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Filter / Safety Grille

Wireless Remote Controller

Model

Ø/V/Hz

kW

Btu/h

kW

Btu/h

W

A

dB(A)

-

m3/min

m3/min

-

-

Ø,mm

Ø,mm

Ø,mm

kg

kg

mm

mm

-

-

AVXTJH036EE

1/220~240/50

HP/HR

3.6

12,200

4.0

13,600

35

0.29

39 / 24 *5)

Turbo Fan

8.7*5)

8.9*5)

R410a

EEV

6.35

12.70

ID 18 hose

15.0

19.0

720x620x199

810x710x295

Filter (Washable)

ARH-1379

Cooling *2)

Heating *3)

Page 50: DVM Catalog

Compact but PowerfulSamsung’s ceiling type air conditioner boasts a slim, compactdesign, half the size of its competitors, with cooling powercomparable to competitor’s larger products.

2way InstallationDepending on the space availability and the purposeof the air conditioner, the indoor unit can be installedunder the ceiling or on the floor.

••• Slim and Compact•••

Ceiling

Indoor Units - Floor & Convertible type

2008 SAMSUNG DVM Air Conditioners Indoor Units

98 99

Indoor Units

OptionalAccessories

INTERIORDESIGNINTERIORINTERIOR

DESIGNDESIGNINTERIORINTERIORDESIGNDESIGN

ANTI-BACTERIA FILTERBACTERIABACTERIABACTERIABACTERIA

LIGHT WEIGHT UNIT

LIGHTLIGHTLIGHTLIGHT FLEXIBLE PIPEINSTALLATIONFlexible PipeFlexible Pipe

InstallationInstallationFlexible PipeFlexible PipeInstallationInstallation

MR-AH01

Individual Controllers

MR-BH01MWR-WS00

Specification | Ceiling

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,

Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.*5) Specifications are subject to change without prior notice for product improvement.*6) Optional Accessory.

Power Source

Mode *1)

Performance

power

Sound

Fan

Airflow Rate

Refrigerant

Piping

Connections

Weight

Set Size

Standard

Accessories

Capacity

Input

Running Current

Sound Pressure (High/Low) *4)

Type

Cooling (High)

Heating (High)

Type

Control Method

Liquid (Flare)

Gas (Flare)

Drain (Quick Lock)

Net Weight

Shipping Weight

Net Dimensions (WxHxD)

Shipping Dimensions (WxHxD)

Filter / Safety Grille

Wireless Remote Controller

Model

Ø/V/Hz

kW

Btu/h

kW

Btu/h

W

A

dB(A)

-

m3/min

m3/min

-

-

Ø,mm

Ø,mm

Ø,mm

kg

kg

mm

mm

-

-

AVXTFH056EE AVXTFH071EE

1/220~240/50

HP/HR

5.6

19,100

6.3

21,400

72

0.33

38 / 32

Sirocco Fan

14.0

14.5

R410a

EEV *6)

6.35

12.70

ID 18 hose

22.0

26.0

1,000x650x200

1,074x726x294

Filter (Washable)

-

1/220~240/50

HP/HR

7.1

24,200

8.0

27,200

80

0.35

41 / 36

Sirocco Fan

18.0

18.5

R410a

EEV *6)

9.52

15.88

ID 18 hose

22.0

26.0

1,000x650x200

1,074x726x294

Filter (Washable)

-

Cooling *2)

Heating *3)

Under Ceiling Floor Standing

MWR-TH01

200%

100%

136%

118% 123%

100%

Size

7.1kW Model

Weight

Smaller Lighter

MWR-SH00

Page 51: DVM Catalog

2008 SAMSUNG DVM Air Conditioners Indoor Units

100 101

Indoor Units

Indoor Units

Indoor Units - ERV System

How it Works

Key Technology

New Diamond Type● Optimized Airflow Design

● High Efficiency Element

● Compact size

Automatic Refresh System (CO2 Sensor) : Optional● ERV is automatically operated to give fresh air into room by sensing CO2 Level.

High Efficiency Motor (BLDC)● Constant air volume by BLDC motor.

Intelligent Operating System (-15˚C) Without Heater

ERV SystemEnergy Recovery Ventilator

WinterIt reduces the costs of heating ventilated air by transferring heatfrom the warm inside air being exhausted to the fresh (but cold)supply air.

SummerThe inside air cools the warmer supply air to reduce ventilationcooling costs.

Samsung’s ERV System has applied the cross flow ventilating method whichassure you efficient ventilation and energy saving. Furthermore, ERV System hasadopted total heat exchange (sensible heat + latent heat) as a heat recoveryprocess that helps maintaining indoor temperature and humidity and minimizingindoor heat loss caused by ventilation

Heat

Heat

HeatHeat

Heat

Heat

Cool

Cool Cool

Cool Cool

CoolCool

IndoorOutdoor

Element

Rectangular Type

Diamond Type

Hexagonal Type

Page 52: DVM Catalog

Indoor Units - ERV System

2008 SAMSUNG DVM Air Conditioners Indoor Units

102 103

Indoor Units

Indoor Units

Energy Saving Operation (Auto Mode)

Extreme Climates (Winter & Summer)When temperature and humidity level difference between indoor andoutdoor is big, it operates as ERV.

Mild Climates (Spring & Fall)When temperature and humidity level difference between indoor andoutdoor is small, it operates as conventional ventilation fan.

It automatically changes operation mode depending on temperature difference between indoorand outdoor to save energy.

Element

EA

OA

EA

OA

RA

SA

RA

SA

Element

Damper

Damper

Specification | ERV System

Line-upRHF025EE

250

RHF035EE350

RHF050EE500

RHF080EE800

RHF100EE1,000

Voltage

Frequency

Withstand Voltage

Insulation Resistance

Air Volume

External Static Pressure

Leakage Rate

Power Input

Current

Temperature Exchange

Efficiency

Effective Enthalpy

Exchange Efficiency

Sound Level

Dust Collection Method

Dimensions (Net)

Dimensions (Gross)

Weight (Net/Gross)

Duct Diameter

Cooling

Heating

Cooling

Heating

WxHxD

WxHxD

Model

V

Hz

-

-

m3/hr

Pa

%

W

A

%

%

%

%

dB(A)

-

mm

mm

kg

Ø,mm

RHF025EE

220~240

50/60

AC1500V, 1min

30MG

250

110

10

115

0.7

70

70

50

70

38

High efficiency filter(PP)

600X350X660

760X400X807

25.5/30

150

RHF035EE

220~240

50/60

AC1500V, 1min

30MG

350

155

10

115

0.7

70

70

50

70

40

High efficiency filter(PP)

1,012X270X1,000

1,299X337X1,183

42.5/53.5

200

RHF050EE

220~240

50/60

AC1500V, 1min

30MG

500

165

10

175

1.1

70

70

50

70

42

High efficiency filter(PP)

1,012X270X1,000

1,299X337X1,183

42.5/53.5

200

RHF080EE

220~240

50/60

AC1500V, 1min

30MG

800

155

10

330

2.1

70

70

50

70

46

High efficiency filter(PP)

1,220X340X1,135

1,475X 440 X1,330

67/75.5

250

RHF100EE

220~240

50/60

AC1500V, 1min

30MG

1,000

155

10

450

2.9

70

70

50

70

48

High efficiency filter(PP)

1,220X340X1,135

1,475X440X1,330

67/75.5

250

Compact Size & Flexible Installation● Compact and Slim in Size by High Efficiency Diamond Element.

Ex.) Model No. RHF-035~050

Page 53: DVM Catalog

Indoor Units - Accessories

2008 SAMSUNG DVM Air Conditioners Indoor Units

104 105

Indoor Units

MXJ-YA1509K

MXJ-YA2512K

MXJ-YA2812K

MXJ-YA2815K

MXJ-YA3119K

MXJ-YA3819K

MXJ-YA4422K

MXJ-HA2512K

MXJ-HA3115K

MXJ-HA3819K

MXJ-YA1500K

MXJ-YA2500K

MXJ-YA3100K

MXJ-YA3800K

MXJ-T3819K

MXJ-T4422K

MXJ-T3100K

MXJ-T3800K

MCU-4EAE1

MCU-4EAEV1

MCU-6EAE1

15.0kW and below

Over 15.0 ~ 40.6kW and below

Over 40.6 ~ 46.4kW and below

Over 46.4 ~ 69.6kW and below

Over 69.6 ~ 98.6kW and below

Over 98.6 ~ 139.2kW and below

Over 139.2kW

Below 46.4kW

46.5 ~ 69.6kW

Over 69.7kW

23.2kW and below

Over 23.2 ~ 63.9kW and below

Over 69.6 ~ 139.2kW and below

Over 139.3kW

Below 48HP

Over 50HP

Below 48HP

Over 50HP

Below 4 indoor units

Below 4 indoor units *1)

Below 6 indoor units

Requisite

Option

Requisite

Requisite

Requisite

Requisite(HR only)

DVM PLUS II,

DVM PLUS II HR

DVM PLUS III,

DVM PLUS III HR

DVM PLUS II,

DVM PLUS II HR

DVM PLUS III,

DVM PLUS III HR

DVM PLUS II, DVM PLUS

II HR, DVM PLUS III, DVM

PLUS III HR (Module)

DVM PLUS III HR

DVM PLUS III HR

(Module)

DVM PLUS II HR,

DVM PLUS III HR

Y-Joint

Header Joint

Y-Joint(Only for DVM PLUS IIIHR in high pressure gasconnection)

Outdoor Joint for DVM PLUS III / HR (Outdoor Connection)

Outdoor Joint only for DVM PLUS III HR Module(High Pressure GasConnection)

MCU Kits

ModelFeatureClassification Description Relevant Unit Remark

MXD-A13K116A

MXD-A13K200A

MXD-A16K200A

MXD-A22K200A

MXD-A13K216A

MXD-A13K300A

MXD-A16K213A

MXD-A16K300A

MEV-A13SA

MEV-A16SA

MDP-E075SEE

MDP-E075SEE1

MDP-M075SGU1

MDP-M075SGU2

MDP-M075SGU3

PSSMA

P2SMA

P4SMA

PMSMA

Below 3.6kW (1 Room) +

5.6 kW~9.0kW (1Room)

Below 3.6kW (2 Rooms)

5.6 kW~9.0kW (2Rooms)

5.6 kW~7.1kW (2Rooms)

Below 3.6kW (2 Rooms) +

5.6 kW~9.0kW (1Room)

Below 3.6kW (3 Rooms)

Below 3.6kW (1 Room) +

5.6 kW~9.0kW (2Rooms)

5.6 kW~9.0kW (3Rooms)

Below 3.6kW (1 Room)

5.6 kW~9.0kW (1Room)

Slim Duct (2.2~7.1) kW

Slim Duct (9.0~14.0) kW

M.S.P Duct (9.0, 11.2) kW

M.S.P Duct (12.8, 14.0) kW

M.S.P Duct (5.6, 7.1) kW

Slim 1 Way Cassette

2 Way Cassette

4 Way Cassette

Mini 4 Way Cassette

Option

Option

Option

Option

Requisite

EEV Kits

Drain PumpDrain Pump

Front Panel

ModelFeatureClassification Description Relevant Unit Remark

Accessories

Wall-mounted &

Ceiling indoor unit

(For 2 indoor units)

Wall-mounted &

Ceiling indoor unit

(For 3 indoor units)

Wall-mounted &

Ceiling indoor unit

(For single unit)

-

-

Notes

*1) MCU-4EAEV1 is the product that includes built in EEV to connect the indoor unit (wall-mounted type and ceiling type) that does notinclude EEV.

Page 54: DVM Catalog

Effective and complete control systems are here. Samsung’s control systems are easy tocontrol, simple and user-friendly. These effective and convenient control systems will not onlycontrol but also monitors, manages and maintain all the information of your air conditioner.Complete control, in your hands.

Control Systems

>> 108_ Integrated Management System >> 116_ Centralized Control System >> 118_ Individual Control System

>> 120_ Building Management System >> 123_ Accessories

imaginethe complete control

106 107

ControlSystems

Control S

ystems

Page 55: DVM Catalog

Control Systems - Integrated Management System

2008 SAMSUNG DVM Air Conditioners Control Systems

108 109

Control S

ystems

IntegratedManagement SystemSamsung’s Integrated Management System provides the

easiest and most convenient way to manage a large number

of air conditioning units at once. This Integrated Management

System will help you control, monitor, manage and maintain

every little detail of your air conditioning needs.

Samsung's Data Management Server (DMS) lets you monitor and control your on-site air conditioningneeds remotely. It's the easiest and most convenient way to manage a large number of air conditioningunits at once.

Data Management Server

DMS

Easy Control & Monitoring

Web Server Function

Schedule Control Function

Power Distribution System

Building Management System

MIM-D00• Built-in web server for PC-independent management and remote access control

• Multiple upper-layer control access (S-NET 3, S-NET Mini, Web-client)

• Individual/Group control of up to 256 indoor units and heat exchange units

• Error history management

• Weekly/Daily schedule control

• Power distribution function

• 2 digital inputs, 2 digital outputs

• Current time management even during power failure (for 24 hours)

• Data storage in non-volatile memory

• Emergency stop function with simple contact interface

Page 56: DVM Catalog

CentralizedController

DMS

Interface Module

Interface Module

Interface Module

CentralizedController

SIM Watt HourMeter

Control Systems - Integrated Management System 110 111

Main Features

Easy Control & Monitoring• Individual/Group control and monitoring up to 256 indoor units.

• Operation mode, temperature setting, airflow direction and

fan speed.

• Wireless/wired remote control restriction.

• Easy multiple/full indoor unit selection.

• Full room temperature display.

• Error history query based on date.

Web Server Function• Built-in web server.

• Multiple upper-layer control access with prioritized management.

• Remote access control with the static IP address.Internet

Anytime, Anywhere Control

2008 SAMSUNG DVM Air Conditioners Control Systems

360kWh

460kWh

140kWh

610kWh

180kWh

Cooling Schedule Setup

Power Distribution System• Power distribution to up to 256 indoor units.

• Data query for watt-hour, use time and use ratio.

• File save in Microsoft Excel format.

• 93 days worth of power distribution data storage.

08:00 AM On 10:00 PM Off

External Contact Interface• Full indoor unit control with simple contact input. (Emergency/Lock)

• State output (Operation/Error) for synchronous control.

Schedule Control Function

DMS System

• Up to 256 schedule settings.

• Weekly, Daily or 1-Day schedule control.

• Exception date setting.

History Management• Easy service and management with error history.

• Occurrence date, error details, current state.

Building Control System

Rapid Service Response

Error History Monitoring

Fire Control System Error Status Indicator

Operation Restriction

Service

Control S

ystems

Page 57: DVM Catalog

Control Systems - Integrated Management System 112 113

Control S

ystems

Control and Monitoring• Control & monitoring of up to 4,096 indoor units

• Heat exchange unit management

• Wireless/wired remote control restriction

• Temperature limit setting

• Multiple/full indoor unit selection

• Icon-based indoor unit display mode

Schedule Control• Graphical schedule settings

• Weekly, Daily schedule control

• Exception date setting

Main Features

• Fully integrated PC management software.

• Up to 16 DMSs connection through the Ethernet.

• Centralized management up to 4,096 indoor/heatexchange units.

• Schedule/Zone control.

• Error/Operation history management.

• Power distribution management and analysis.

• Automatic update through the Internet.

S-NET 3

S-NET 3

Supports 16 DMSs ▼

Max. 16 units

Smart Net Control SystemS-NET is a complex management program that controls and monitors a complete air conditioner networksystem. The S-NET series provides flexible and complete control for a variety of applications.

Zone Management• Management structure customization regardless of installation structure• Control zone creation/edition/deletion• Tree structure zone management control

Power Distribution Management• Data query for power distribution and operation time

• Power distribution report generation and print

• Time section setting for different electricity rates

• Group setting for power distribution summation

History Management• Error/Event history management

• Indoor unit operation history management

• Report generation and print

Cycle monitoring• Monitoring outdoor / indoor unit cycle data

(Supported for specific outdoor unit models)

2008 SAMSUNG DVM Air Conditioners Control Systems

Page 58: DVM Catalog

2008 SAMSUNG DVM Air Conditioners Control Systems

Control Systems - Integrated Management System 114 115

Control S

ystems

• Dynamic compatibility options (DMS, centralized controller, interface module)• Control and monitoring of up to 256 indoor units• Detailed cycling information monitoring• Schedule function (Weekly, Daily)• USB keyboard supported • Error display • 7-inch wide LCD restriction • Temperature limit setting • Touch screen• Zone control• Child-lock setting

S-NET mini

Supports 16

InterfaceModules

Supports 4 DMSs ▼

Supports 16

CentralizedControllers

Control and monitoring

Dynamic Compatibility Option

• Control & Monitor up to 256 indoor units• Operation control and monitoring• Detailed operation cycling information monitoring• Wireless/wired remote control restriction setting

Schedule Control• Maximum 256 Weekly, Daily schedule control

• Schedule repetition, exception date setting

• Schedule edit (add, edit, delete)

• Detailed operation schedule setting

• Remote control restriction option setting

Main Features

Zone Management• Management structure customization regardless of installation structure • Control zone creation/edition/deletion

Temperature Limit Setting• Upper/Lower temperature limit setting

Cycle Monitoring• Outdoor/Indoor unit cycling information monitoring

(supported for specific outdoor unit models)

Error Management• Error history management• Error management information query• Detailed error information query

Page 59: DVM Catalog

2008 SAMSUNG DVM Air Conditioners Control Systems

Control Systems - Centralized Control System 116 117

Control S

ystems

CentralizedControl SystemSamsung's advanced technology has come up with the centralized

control that is convenient and efficient. Samsung's centralized control

system can control and monitor 4,096 individual indoor units and 256

groups of indoor units simultaneously.

Function Icon

ON/OFF, OPERATION MODE, FAN SPEED,AIRFLOW, TEMPERATURE SETTING

OperationOperationOperationOperation INDIVIDUAL AND GROUP CONTROL (MAXIMUM 16 INDOOR UNITS)

GroupGroupGroupGroup

ERROR DISPLAYErrorErrorErrorError

FILTER REPLACEMENT ALARM RESETFilterFilterFilterFilter

MCM-A202A

• Maximum 16 group controls (Maximum 256 Indoor units)• Unified/Individual indoor unit control (On/Off)• Wireless/wired remote control restriction• Cooling/Heating mode control• Indoor unit error display

Centralized ControllerMCM-A100

• Control and monitoring of up to 16 indoor unit groups

Function Controller

• Communicator between indoor/outdoor units andthe centralized controller

Interface ModuleMIM-B13A

• Operation mode selection (Cooling, Heating or Auto) • Mixed operation mode protection

Operation Mode Selection SwitchMCM-C200

MIM-B04A

To use Function Controller, it requires to be connected to MCM-A202A

OperationOperationOperationOperation ErrorErrorErrorError FilterFilterFilterFilter

S-NET II Plus• Indoor unit control of up to 256 groups• Extensive individual control of up to 4096 indoor units• Weekly and Daily schedule function• Zone setting and control• Dynamic exchange to Permitted and Prohibited wireless/wired remote control• Full/Group/Individual indoor unit display

256 group 4096 indoor units controls Zone controlSchedule controlIndividual control

Max. 16 units

RS232-RS485Converter

S-NET II Plus

Page 60: DVM Catalog

2008 SAMSUNG DVM Air Conditioners Control Systems

Control Systems - Building Management System 120 121

Control S

ystems

BuildingManagement SystemBMS (Building Management System) makes it possible to control and

monitor the air conditioning network using the remote control and

monitoring function.

Optimum control keeps the air conditioning system efficient, saves energy,

reduces maintenance costs, and extends the life cycle of the units.

MIM-B07• Interface for Lon-Connection to Lonworks management system

• Quick and easy installation

• Up to 12 indoor units can be controlled

• Communication : 485 to Lonworks

• Upper physical layer : FTT-10A

BMS Control Function

• On/Off control• Temperature setting• Operation mode• Fan speed

Monitoring Function

• On/Off• Operation mode• Room temperature• Error information

Guest Room Management System

External Contact Interface Module

The Guest Room Management System is asmart way to save energy and money.When the Key Tag is in place, the air conditioneris activated. When the Key Tag is removed,the air conditioner turns off. Now you canavoid cooling an unoccupied room and saveenergy.

ON OFF

MIM-B14• Direct indoor unit control by external contact signal

• Window-synchronized indoor unit control

• Emergency control with simple contact input

• Indoor unit operation/error state output through relay contacts

MIM-B02• Indoor unit control by external contact signals

• Individual/Group control of up to 16 indoor units

• Combinational use with sensor/timer/emergency inputs

Room 501

Key-Holder

Room 502

Key-Holder

Room 503

Key-Holder

Room 504

Key-Holder

Page 61: DVM Catalog

2008 SAMSUNG DVM Air Conditioners Control Systems

Control Systems - Individual Control System 118 119

Control S

ystems

IndividualControl SystemThere are many ways to control your air conditioner, but one

smart controller is all you need. Samsung provides several

different control options that can control one indoor unit to a

group of indoor units with one system.

Function Icon

ON/OFF, OPERATION MODE, FAN SPEED,AIRFLOW, TEMPERATURE SETTING

OperationOperationOperationOperation INDIVIDUAL AND GROUP CONTROL (MAXIMUM 16 INDOOR UNITS)

GroupGroupGroupGroup

ERROR DISPLAYErrorErrorErrorError

FILTER REPLACEMENT ALARM RESETFilterFilterFilterFilter

MWR-WS00 (Premium)

• Weekly schedule setting (Maximum 70 schedules)• Exception date setting• Built-in room temperature sensor• Clear and bright screen with LCD backlight• Temperature limit setting• Wireless remote control restriction• Automatic Stop mode • Sleep and Silent mode• Child lock

• Mode selection protection

MWR-TH01

Wired Remote Controller

MWR-SH00

Simplified wired remote controller

• Individual and group control (Maximum 16ERVs)

• On/Off control• Operation mode (By-Pass, Heat Exchange),

fan speed• Simple schedule control• Error display• Synchronous operation with indoor units

MWR-VH01

ERV Wired remote controller

• Simple schedule control• Wireless remote control restriction

OperationOperationOperationOperation GroupGroupGroupGroup ErrorErrorErrorError FilterFilterFilterFilter

OperationOperationOperationOperation GroupGroupGroupGroup ErrorErrorErrorError FilterFilterFilterFilter

• ON/OFF control• Operation indication• Error Indication• Filter replacement sign• Use with receiver wire, MRW-10A

MRK-A00

Wireless Signal Receiver (for Duct-type indoor unit)

• Up to 100 weekly and daily schedulesettings

• Schedule setting based on 1-minutetime units

• Digital clock display• Permanent schedule setting storage• Current time protection from blackout

(maximum 3 days)• Use with wired remote controller, or

centralized controller.(MWR-TH01, MCM-A202A)

MWR-BS00

7-day Scheduler

OperationOperationOperationOperation GroupGroupGroupGroup ErrorErrorErrorError FilterFilterFilterFilter

• Compact size• Simple schedule control• Soft touch button

MR-BH01 MR-AH01

• Simple schedule control• Wide display• Soft touch button

Wireless Remote Controller

OperationOperationOperationOperation FilterFilterFilterFilter OperationOperationOperationOperation FilterFilterFilterFilter

Page 62: DVM Catalog

Room01(60kWh)

Room04(210kWh) 600kWh

Room03(210kWh)

Room02(120kWh)

RS 485

RS 485

Power Supply

2008 SAMSUNG DVM Air Conditioners Control Systems

Control Systems - Building Management System

Control S

ystems

Power Distribution Unit

MCM-B102• Real-time power distribution for one indoor/outdoor system.

• Power distribution to maximum 48 indoor units.

• Communication error display.

• Total system power consumption display.

• Power consumption display of individual indoor units.

• Data storage even during a power failure.

• Consult with Samsung Electronics for watt-hour meter interface

= x

Room01

Room02

Room03

Room04

40%

30%

20%

10%

0%Room01 Room02 Room03 Room04

20% 19.4%

35.0%35.3% 35.0%35.1%

Actual Usage Rate

Displayed Rate

10.2% 10.2%

Room 01 electric powerconsumption

Total powerconsumption

Demand capacityof Room 01

Total demand capacityof indoor units

• Exclusive use for DMS power distribution.• Connection with up to 8 watt-hour meters.• RS485 interface with watt-hour meters.• Power consumption display for each watt-hour meter.• Automatic detection of specified watt-hour meters.

MIM-B12

Watt-hour meter Interface Module

Classification Product Model Image Application Model

IntegratedManagementSystem

Controller

InterfaceModule

DMS MIM-D00 DVM Series, FJM, CAC, ERV

DVM Series, FJM, CAC, ERV

DVM Series, FJM, CAC

S-NET 3 MST-P3P

S-NET mini MST-S3W

DVM Series, FJMSiM MIM-B12

CentralizedControlSystem

InterfaceModule

S-NET II Plus MSP-S1P DVM, DVM HR, DVM PLUS II, DVM PLUS II HR, FJM, CAC

DVM Series, FJM, CAC, ERV

DVM Series, FJM, CAC

Mini DVM(R410A), DVM PLUS II, DVM PLUSII HR, DVM PLUS III, DVM PLUS III HR, FJM,ERV

MCM-A202A

Controller

Centralized Controller

MCM-A100Function Controller

MIM-B13ACentralized Control Interface Module

DVM, DVM PLUS, DVM HR, CACMIM-B04A

Accessories

DVM SeriesMCM-C200Operation Mode Selection Switch

DVM Series, FJMPower Distribution Unit

DVM Series : Mini DVM, DVM, DVM PLUS, DVM HR, DVM PLUS II, DVM PLUS IIHR, DVM PLUS III, DVM PLUS IIIHR

MCM-B102

Mini DVM(R410A), DVM PLUS II, DVM PLUS II HR, DVM PLUS III, DVM PLUS III HR (Non RAC/Console)

External Contact Interface Module MIM-B14

Building ManagementSystem

Lonworks Interface Module MIM-B07 DVM Series, FJM

Power Distribution

DVM Series, FJM Key-tag Interface Module MIM-B02Guest RoomManagementSystem

IndividualControlSystem

Controller Wireless Remote Controller MR-AH01MR-BH01

Cassette, Ceiling, Duct (Receiverneeded), Console (Included)

Cassette, Wall Mounted, Ceiling, Duct, Console

Cassette, Wall Mounted, Ceiling, Duct, Console

Duct (For Wireless Remote Controller)

Duct (For Wireless Remote Controller)

Cassette, Wall Mounted, Ceiling, Duct

Wired Remote Controller (Premium) MWR-WS00

Wired Remote Controller MWR-TH01

Cassette, Wall Mounted, Ceiling, Duct, Console

Simplified Wired Remote Controller MWR-SH00

ERVERV Wired Remote Controller MWR-VH01

Wireless SignalReceiver Kit

MRK-A00Wireless Signal Receiver

Receiver Wire MRW-10A

7-day Scheduler MWR-BS00