INDEX SHEET
DETAIL #:
DATE:
XX-XX-XX-DW4V
DW-4000 - VERTICAL INSTALLATION
AR-PJ-01-DW4V 2" VERTICAL PANEL JOINT
AR-PJ-02-DW4V 2 1/2" VERTICAL PANEL JOINT
AR-PJ-03-DW4V 3" VERTICAL PANEL JOINT
AR-PJ-04-DW4V 4" VERTICAL PANEL JOINT
AR-PJ-05-DW4V 2" VERTICAL PANEL W/
1
2
" REVEAL
AR-PJ-06-DW4V 2 1/2" VERTICAL PANEL W/
1
2
" REVEAL
AR-PJ-07-DW4V 3" VERTICAL PANEL W/
1
2
" REVEAL
AR-PJ-08-DW4V 4" VERTICAL PANEL W/
1
2
" REVEAL
AR-PJ-09-DW4V PANEL W/ CUSTOM REVEAL
AR-PJ-10-DW4V DW4000S PANEL PROFILE
AR-PJ-11-DW4V PANELS OVER STRUCTURAL STEEL
AR-PJ-12-DW4V PANELS OVER METAL STUDS
AR-PJ-13-DW4V PANELS OVER CONCRETE
AR-PJ-14-DW4V DESIGNWALL 2000 TO 4000
AR-PJ-15-DW4V DESIGNWALL 2000 TO 4000
AR-BS-01-DW4V BASE DETAIL - OVERHANG
AR-BS-02-DW4V BASE DETAIL - FLUSH
AR-BS-03-DW4V FLUSH BASE WITH EXTRUSION
AR-BS-04-DW4V OVERHANG BASE WITH EXTRUSION
AR-OC-01-DW4V 2" PANEL OUTSIDE CORNER W/ 2-PC EXTRUSION
AR-OC-02-DW4V 3" PANEL OUTSIDE CORNER W/ 2 PC EXTRUSION
AR-OC-03-DW4V 4" PANEL OUTSIDE CORNER W/ 2 PC EXTRUSION
AR-OC-05-DW4V OUTSIDE CORNER WITH FLASHING
AR-IC-01-DW4V INSIDE CORNER WITH 2-PC EXTRUSION
AR-IC-02-DW4V INSIDE CORNER WITH FLASHING
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
INDEX SHEET
DETAIL #:
DATE:
XX-XX-XX-DW4V
DW-4000 - VERTICAL INSTALLATION
AR-FO-01-DW4V DOOR HEAD W/ DRIP EDGE
AR-FO-02-DW4V DOOR HEAD WITH EXTRUSION
AR-FO-03-DW4V DOOR JAMB WITH FLASHING
AR-FO-04-DW4V DOOR JAMB WITH EXTRUSION
AR-FO-05-DW4V WINDOW. HEAD WITH EXTRUSION
AR-FO-06-DW4V WINDOW HEAD WITH FLASHING
AR-FO-07-DW4V WINDOW JAMB WITH EXTRUSION
AR-FO-08-DW4V WINDOW JAMB WITH FLASHING
AR-FO-09-DW4V WINDOW SILL WITH EXTRUSION
AR-FO-10-DW4V WINDOW SILL WITH FLASHING
AR-FO-11-DW4V LOUVER W/ FIELD CUT HEAD
AR-FO-12-DW4V LOUVER WITH FIELD CUT JAMB
AR-FO-13-DW4V LOUVER SILL WITH FIELD CUT END
AR-SF-01-DW4V SOFFIT W/ EXTRUSION
AR-SF-02-DW4V SOFFIT W/ FLASHING
AR-SF-03-DW4V TRANSVERSE BENT SOFFIT
AR-SF-04-DW4V END WALL W/ EXTRUSION
AR-SF-05-DW4V END WALL W/ FLASHING
AR-SJ-01-DW4V STACK JOINT
AR-SJ-02-DW4V STACK JOINT W/ EXTRUSION
AR-PR-01-DW4V PARAPET COPING
AR-PR-02-DW4V PARAPET W/ FLUSH TRIM
AR-PR-03-DW4V PARAPET W/ PROFILED TRIM
AR-TL-01-DW4V WALL PENETRATION
AR-TL-02-DW4V PIPE PENETRATION
AR-TL-03-DW4V PENETRATION DETAIL
AR-TL-04-DW4V TRIM END LAP
AR-TL-05-DW4V TRIM END LAP WITH HEM
AR-TL-06-DW4V MENDING PLATE WITH SHINGLE LAP
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
INDEX SHEET
DETAIL #:
DATE:
XX-XX-XX-DW4V
DW-4000 - VERTICAL INSTALLATION
AR-TL-07-DW4V TRIM END LAP WITH LAP STRIP
AR-TL-08-DW4V TRIM AT FRAMED OPENING
AR-TL-09-DW4V 2" EXTRUSION
AR-TL-10-DW4V 2" EXTRUSION
AR-TL-11-DW4V 2.5" EXTRUSION
AR-TL-12-DW4V 3" EXTRUSION
AR-TL-13-DW4V 4" EXTRUSION
AR-TL-14-DW4V EXTRUSION LAP STRIPS
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
ARCHITECTURAL
DISCLAIMER
DETAIL #:
DATE:
AR-DS-01-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
DISCLAIMERS:
THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED
COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.
LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASED
ON TYPICAL DESIGN PRACTICES FOR MOST U.S. CLIMACTIC ZONES. (THE PRIMARY VAPOR
BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER).
FOR CLARITY, ALL DETAILS SHOWN WITH (1)
1
4
"-14 HEX HEAD FASTENER WITH WASHER -
CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS
PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY
REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES
FOR SPECIFIC PROJECT RECOMMENDATIONS.
ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION
PURPOSES ONLY.
6/25/21
DIRECTION OF INSTALLATION
CONTACT KINGSPAN TECHNICAL SERVICES
FOR SPECIFIC PROJECT FASTENING REQUIREMENTS
FASTENING CLIP
1/16" NOMINAL JT.
24", 30" OR 36" MODULE STANDARD
FACE OF PANEL
HORIZONTAL SUPPORT
BY OTHERS
S.S. FASTENING CLIP WITH PVC
FOAM TAPE STRIP SEAL
FACE SHEET WEDGE GASKET
2"
(2)1/4"-14 x 2" DP3 HWH FASTENER
PER CLIP. (USE 3" WHEN FASTENING
THROUGH SHEATHING/DENSGLASS)
*PRE-DRILLING REQ'D*
FACTORY BUTYL CAULK INSIDE
POCKET OF LINER SHEET
2" VERTICAL
PANEL JOINT
DETAIL #:
DATE:
AR-PJ-01-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
FASTENING CLIP
CONTACT KINGSPAN TECHNICAL SERVICES
FOR SPECIFIC PROJECT FASTENING REQUIREMENTS
2
1
2
"
DIRECTION OF INSTALLATION
FACE OF PANEL
S.S. FASTENING CLIP WITH PVC
FACE SHEET WEDGE GASKET
FOAM TAPE STRIP SEAL
HORIZONTAL SUPPORT
BY OTHERS
1/16" NOMINAL JT.
24", 30" OR 36" MODULE STANDARD
(2)1/4"-14 x 2 1/2" DP3 HWH FASTENER
PER CLIP. (USE 4" WHEN FASTENING
THROUGH SHEATHING/DENSGLASS)
*PRE-DRILLING REQ'D*
FACTORY BUTYL CAULK INSIDE
POCKET OF LINER SHEET
2 1/2" VERTICAL
PANEL JOINT
DETAIL #:
DATE:
AR-PJ-02-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
CONTACT KINGSPAN TECHNICAL SERVICES
FOR SPECIFIC PROJECT FASTENING REQUIREMENTS
FASTENING CLIP
3"
DIRECTION OF INSTALLATION
FACE OF PANEL
S.S. FASTENING CLIP WITH PVC
FACE SHEET WEDGE GASKET
FOAM TAPE STRIP SEAL
HORIZONTAL SUPPORT
BY OTHERS
1/16" NOMINAL JT.
24", 30" OR 36" MODULE STANDARD
(2)1/4"-14 x 3" DP3 HWH FASTENER
PER CLIP. (USE 4" WHEN FASTENING
THROUGH SHEATHING/DENSGLASS)
*PRE-DRILLING REQ'D*
FACTORY BUTYL CAULK INSIDE
POCKET OF LINER SHEET
3" VERTICAL
PANEL JOINT
DETAIL #:
DATE:
AR-PJ-03-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
CONTACT KINGSPAN TECHNICAL SERVICES
FOR SPECIFIC PROJECT FASTENING REQUIREMENTS
FASTENING CLIP
4"
DIRECTION OF INSTALLATION
FACE OF PANEL
S.S. FASTENING CLIP WITH PVC
FACE SHEET WEDGE GASKET
FOAM TAPE STRIP SEAL
HORIZONTAL SUPPORT
BY OTHERS
1/16" NOMINAL JT.
24", 30" OR 36" MODULE STANDARD
(2)1/4"-14 x 4" DP3 HWH FASTENER
PER CLIP. (USE 5" WHEN FASTENING
THROUGH SHEATHING/DENSGLASS)
*PRE-DRILLING REQ'D*
FACTORY BUTYL CAULK INSIDE
POCKET OF LINER SHEET
4" VERTICAL
PANEL JOINT
DETAIL #:
DATE:
AR-PJ-04-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
DIRECTION OF INSTALLATION
FASTENING CLIP
CONTACT KINGSPAN TECHNICAL SERVICES
FOR SPECIFIC PROJECT FASTENING REQUIREMENTS
FACE OF PANEL
HORIZONTAL SUPPORT
BY OTHERS
S.S. FASTENING CLIP WITH PVC
FOAM TAPE STRIP SEAL
FACE SHEET WEDGE GASKET
2"
1/2" REVEAL
24", 30" OR 36" MODULE STANDARD
(2)1/4"-14 x 2" DP3 HWH FASTENER
PER CLIP. (USE 3" WHEN FASTENING
THROUGH SHEATHING/DENSGLASS)
*PRE-DRILLING REQ'D*
FACTORY BUTYL CAULK INSIDE
POCKET OF LINER SHEET
2" VERTICAL PANEL
W/
1
2
" REVEAL
DETAIL #:
DATE:
AR-PJ-05-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
FASTENING CLIP
CONTACT KINGSPAN TECHNICAL SERVICES
FOR SPECIFIC PROJECT FASTENING REQUIREMENTS
2
1
2
"
DIRECTION OF INSTALLATION
FACE OF PANEL
FACE SHEET WEDGE GASKET
HORIZONTAL SUPPORT
BY OTHERS
S.S. FASTENING CLIP WITH PVC
FOAM TAPE STRIP SEAL
1/2" REVEAL
24", 30" OR 36" MODULE STANDARD
(2)1/4"-14 x 2 1/2" DP3 HWH FASTENER
PER CLIP. (USE 4" WHEN FASTENING
THROUGH SHEATHING/DENSGLASS)
*PRE-DRILLING REQ'D*
FACTORY BUTYL CAULK INSIDE
POCKET OF LINER SHEET
DETAIL #:
DATE:
AR-PJ-06-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
2 1/2" VERTICAL PANEL
W/
1
2
" REVEAL 6/25/21
CONTACT KINGSPAN TECHNICAL SERVICES
FOR SPECIFIC PROJECT FASTENING REQUIREMENTS
FASTENING CLIP
3"
DIRECTION OF INSTALLATION
FACE OF PANEL
FACE SHEET WEDGE GASKET
HORIZONTAL SUPPORT
BY OTHERS
S.S. FASTENING CLIP WITH PVC
FOAM TAPE STRIP SEAL
1/2" REVEAL
24", 30" OR 36" MODULE STANDARD
(2)1/4"-14 x 3" DP3 HWH FASTENER
PER CLIP. (USE 4" WHEN FASTENING
THROUGH SHEATHING/DENSGLASS)
*PRE-DRILLING REQ'D*
FACTORY BUTYL CAULK INSIDE
POCKET OF LINER SHEET
DETAIL #:
DATE:
AR-PJ-07-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
3" VERTICAL PANEL
W/
1
2
" REVEAL
6/25/21
CONTACT KINGSPAN TECHNICAL SERVICES
FOR SPECIFIC PROJECT FASTENING REQUIREMENTS
FASTENING CLIP
4"
DIRECTION OF INSTALLATION
FACE OF PANEL
FACE SHEET WEDGE GASKET
HORIZONTAL SUPPORT
BY OTHERS
S.S. FASTENING CLIP WITH PVC
FOAM TAPE STRIP SEAL
1/2" REVEAL
24", 30" OR 36" MODULE STANDARD
(2)1/4"-14 x 4" DP3 HWH FASTENER
PER CLIP. (USE 5" WHEN FASTENING
THROUGH SHEATHING/DENSGLASS)
*PRE-DRILLING REQ'D*
FACTORY BUTYL CAULK INSIDE
POCKET OF LINER SHEET
DETAIL #:
DATE:
AR-PJ-08-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
4" VERTICAL PANEL
W/
1
2
" REVEAL
6/25/21
CONTACT KINGSPAN TECHNICAL SERVICES
FOR SPECIFIC PROJECT FASTENING REQUIREMENTS
FASTENING CLIP
DIRECTION OF INSTALLATION
FACE OF PANEL
FACE SHEET WEDGE GASKET
(2) 1/4"-14 HWH FASTENERS PER CLIP
HORIZONTAL SUPPORT
BY OTHERS
6" MAX.
24", 30" OR 36" MODULE STANDARD
REVEAL MODIFICATION
BUILT INTO MALE EDGE
OF PANEL
11
16
"
2", 2
.5
", 3
", O
R 4
"
S.S. FASTENING CLIP WITH PVC
FOAM TAPE STRIP SEAL
24", 30" OR 36" MODULE STANDARD
*PRE-DRILLING REQ'D*
FACTORY BUTYL CAULK INSIDE
POCKET OF LINER SHEET
PANEL W/ CUSTOM
REVEAL
DETAIL #:
DATE:
AR-PJ-09-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
24", 30", OR 36" MODULE STANDARD
3
4
" STRIATION PITCH
FACE OF PANEL
REVEAL
2", 2.5", 3", O
R 4"
STRIATED FACE SHEET
STRIATION DEPTH
.035 INCH
FACE SHEET WEDGE GASKET
FACTORY BUTYL CAULKING
DETAIL #:
DATE:
AR-PJ-10-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
DW4000S PANEL
PROFILE
6/25/21
HORIZONTAL
GIRT
HORIZONTAL
ANGLE
HORIZONTAL
GIRT
VERTICAL
PANELS
ALWAYS ATTACH VERTICAL PANELS
TO HORIZONTALLY ORIENTED
SUPPORTS
PANELS OVER
STRUCTURAL STEEL
DETAIL #:
DATE:
AR-PJ-11-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
HORIZONTAL
SUBGIRT
VERTICAL
PANELS
HORIZONTAL
SUBGIRT
HORIZONTAL
SUBGIRT
VERTICAL
STUDS
SHEATHING
OPTIONAL
HORIZONTAL
SUBGIRT
ALWAYS ATTACH VERTICAL PANELS
TO HORIZONTALLY ORIENTED
SUPPORTS
PANELS OVER METAL
STUDS
DETAIL #:
DATE:
AR-PJ-12-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
HORIZONTAL
SUBGIRT
HORIZONTAL
SUBGIRT
HORIZONTAL
SUBGIRT
HORIZONTAL
SUBGIRT
PRECAST OR
CMU WALL
ALWAYS ATTACH VERTICAL PANELS
TO HORIZONTALLY ORIENTED
SUPPORTS
VERTICAL
PANELS
*SUBGIRT DEPTH MUST BE
NO SHALLOWER THAN
SHANK PENETRATION OF
FASTENERS BEHIND LINER
SHEET
PANELS OVER
CONCRETE
DETAIL #:
DATE:
AR-PJ-13-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
DIRECTION OF INSTALLATION
DESIGNWALL 2000 PANEL
FACE SHEET WEDGE GASKET
HORIZONTAL SUPPORT
BY OTHERS
24", 30" OR 36" MODULE STANDARD
DESIGNWALL 4000 PANEL
APPLY BUTYL CAULK INSIDE
FEMALE POCKET OF LINER
SHEET OF DESIGNWALL 2000
PANEL PRIOR TO JOINT
ENGAGEMENT WITH
DESIGNWALL 4000 PANEL
DO NOT ENGAGE MALE LEG OF
DW4000 INTO EMPTY POCKET
WITH NO SEAL
(2)1/4"-14 x 3" DP3 HWH FASTENER
PER CLIP. (USE 4" WHEN FASTENING
THROUGH SHEATHING/DENSGLASS)
*PRE-DRILLING REQ'D*
DW2000 TO DW4000
DETAIL #:
DATE:
AR-PJ-14-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
REMOVE FINNED GASKET FROM
MALE LEG OF LINER SHEET OF
DESIGNWALL 2000 PANEL
PRIOR TO JOINT ENGAGMENT
WITH DESIGNWALL 4000 PANEL
DO NOT ENGAGE GASKET INTO
FACTORY BUTYL CAULK
DIRECTION OF INSTALLATION
DESIGNWALL 4000 PANEL
FACE SHEET WEDGE GASKET
HORIZONTAL SUPPORT
BY OTHERS
24", 30" OR 36" MODULE STANDARD
DESIGNWALL 2000 PANEL
(2)1/4"-14 x 3" DP3 HWH FASTENER
PER CLIP. (USE 4" WHEN FASTENING
THROUGH SHEATHING/DENSGLASS)
*PRE-DRILLING REQ'D*
DW2000 TO DW4000
DETAIL #:
DATE:
AR-PJ-15-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
2", 2
1
2
", 3", OR 4"
STEEL BASE ANGLE
BY OTHERS SEAL TO SLAB
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PRE-DRILLING REQ'D*
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
CONTINUOUS BUTYL SEALANT
TRIMLESS END
BASE FLASHING
BASE DETAIL -
OVERHANG
DETAIL #:
DATE:
AR-BS-01-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
TRIMLESS END
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PRE-DRILLING REQ'D*
2", 2
1
2
", 3", OR 4"
CONTINUOUS BUTYL SEALANT
STEEL BASE ANGLE
BY OTHERS SEAL TO SLAB
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
BASE FLASHING
URETHANE SEALANT
NOT BY KINGSPAN
BASE DETAIL - FLUSH
DETAIL #:
DATE:
AR-BS-02-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
ALUMINUM BASE
EXTRUSION
1/4" DIA. WEEP HOLE
24" O.C. FIELD DRILLED
1"
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PRE-DRILLING REQ'D*
2", 2
1
2
", 3", OR 4"
FIELD CUT 6" SPLICE PLATE
FROM SPLICE EXTRUSION
NOTE: BREAKFORMED SPLICE FOR 2
1
2
" AND 4" PANEL EXTRUSIONS
CONTINUOUS BUTYL SEALANT
STEEL BASE ANGLE
BY OTHERS SEAL TO SLAB
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
4" F
OR
2" &
2.5" P
AN
ELS
5" F
OR
3" &
4" P
AN
ELS
FLUSH BASE WITH
EXTRUSION
DETAIL #:
DATE:
AR-BS-03-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
ALUMINUM BASE
EXTRUSION
1/4" DIA. WEEP HOLE
24" O.C. FIELD DRILLED
4" F
OR
2" &
2.5" P
AN
ELS
1"
2", 2
1
2
", 3", OR 4"
FIELD CUT 6" SPLICE PLATE
FROM SPLICE EXTRUSION
NOTE: BREAKFORMED SPLICE FOR 2
1
2
" AND 4" PANEL EXTRUSIONS
STEEL BASE ANGLE
BY OTHERS SEAL TO SLAB
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PRE-DRILLING REQ'D*
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
CONTINUOUS BUTYL SEALANT
5" F
OR
3" &
4" P
AN
ELS
OVERHANG BASE W/
EXTRUSION
DETAIL #:
DATE:
AR-BS-04-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
2-PC SNAP-TOGETHER OUTSIDE
CORNER EXTRUSION 3.5" x 3.5"
GIRT LINE
3
1
2
"
3
1
2
"
FIELD CUT
PANELS TO SUIT
2
"
F.I.P. INSULATION
(NOT BY KINGSPAN)
BUTYL SEALANT
" - 14 "LOW PROFILE" FASTENER
AT GIRTS
OUTSIDE CORNER
WITH 2-PC EXTRUSION
DETAIL #:
DATE:
AR-OC-01-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
2-PC SNAP-TOGETHER OUTSIDE
CORNER EXTRUSION 5" x 5"
GIRT LINE
FIELD CUT
PANELS TO SUIT
3
"
BUTYL SEALANT
5
"
5
"
SEALANT
1
4
" - 14 "LOW PROFILE" FASTENER
AT GIRTS
3" PANEL OUTSIDE
CORNER W/
2 PC EXTRUSION
DETAIL #:
DATE:
AR-OC-02-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
2-PC SNAP-TOGETHER OUTSIDE
CORNER EXTRUSION 6" x 6"
GIRT LINE
FIELD CUT
PANELS TO SUIT
4
"
BUTYL SEALANT
6
"
6
"
SEALANT
1
4
" - 14 "LOW PROFILE" FASTENER
AT GIRTS
DETAIL #:
DATE:
AR-OC-03-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
4" PANEL OUTSIDE
CORNER W/
2 PC EXTRUSION
6/25/21
GIRT LINE
(2) 1/4"-14 HWH FASTENERS
S.S. FASTENING CLIP WITH PVC
FOAM TAPE STRIP SEAL
2", 2
1
2
", 3", OR 4"
FORMED CORNER TRIM
POP RIVETS 12" O.C.
SEALANT
FIELD CUT
PANELS TO SUIT
1
4
" - 14 DP3 CONCEALOR SCREW
AT GIRTS
BUTYL SEALANT
INTERIOR MENDING PLATE
FASTEN TO LINER SHEET
PER CLIP *PRE-DRILLING REQ'D*
DETAIL #:
DATE:
AR-OC-05-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
OUTSIDE CORNER W/
FLASHING6/25/21
FIELD CUT
PANELS TO SUIT
CONTINUOUS BUTYL SEALANT
2
"
O
R
3
"
GIRT LINE
SEALANT
2-PC SNAP-TOGETHER INSIDE
CORNER EXTRUSION 2.5" x 2.5"
2
1
2
"
*NOTE: 2-PC INSIDE CORNER EXTRUSION AVAILABLE FOR 2" AND 3" PANELS ONLY
1
4
" - 14 "LOW PROFILE" FASTENER
AT GIRTS
INSIDE CORNER
WITH 2-PC EXTRUSION
DETAIL #:
DATE:
AR-IC-01-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
GIRT LINE
(2) 1/4"-14 HWH FASTENERS
S.S. FASTENING CLIP WITH PVC
FOAM TAPE STRIP SEAL
2", 2
1
2
", 3
", O
R 4
"
1
4
" - 14 "LOW PROFILE" FASTENER
AT GIRTS
FIELD CUT
PANELS TO SUIT
FORMED CORNER TRIM
SEALANT
POP RIVETS 12" O.C.
BUTYL SEALANT
INTERIOR MENDING PLATE
FASTEN TO LINER SHEET
CLIP *PRE-DRILLING REQ'D*
INSIDE CORNER WITH
FLASHING
DETAIL #:
DATE:
AR-IC-02-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
EXTERIOR CAP TRIM
POP RIVETS
EXPOSED SEALANT
(NOT BY KINGSPAN)
FIELD CUT PANEL TO SUIT
DOOR FRAME
(NOT BY KINGSPAN)
FRAMED OPENING
(NOT BY KINGSPAN)
2", 2.5", 3", OR 4"
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
NOTE: 1) SEE DETAIL AR-TL-04-DW4H, AR-TL-05-DW4H, AR-TL-06-DW4H, AR-TL-07-DW4H
AND AR-TL-08-DW4H FOR TYPICAL TRIM LAP INSTRUCTIONS
HORIZONTAL SUPPORTS
NOT BY KINGSPAN
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
2-PC HEAD FLASHING
NON-SKINNING BUTYL
APPLIED BETWEEN
FLASHING PIECES
DOOR HEAD W/ DRIP
EDGE
DETAIL #:
DATE:
AR-FO-01-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
EXPOSED SEALANT
(NOT BY KINGSPAN)
FIELD CUT PANEL TO SUIT
DOOR FRAME
(NOT BY KINGSPAN)
FRAMED OPENING
(NOT BY KINGSPAN)
2", 2.5", 3", OR 4"
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
STANDARD SOFFIT
EXTRUSION
1"
HORIZONTAL SUPPORTS
NOT BY KINGSPAN
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
DOOR HEAD WITH
EXTRUSION
DETAIL #:
DATE:
AR-FO-02-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
FRAMED OPENING
(NOT BY KINGSPAN)
DOOR FRAME
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
POP RIVETS
JAMB TRIM
FIELD CUT PANELS TO SUIT
2", 2.5", 3", O
R 4"
1
4
" - 14 "LOW PROFILE" FASTENER
SEALANT
HORIZONTAL SUPPORTS
NOT BY KINGSPAN
NON-SKINNING BUTYL APPLIED
BETWEEN JAMB TRIM AND
JAMB MENDING PLATE
JAMB MENDING PLATE
CONTINUOUS BUTYL SEALANT
NOTE: 1) SEE DETAIL AR-TL-04-DW4H, AR-TL-05-DW4H, AR-TL-06-DW4H, AR-TL-07-DW4H
AND AR-TL-08-DW4H FOR TYPICAL TRIM LAP INSTRUCTIONS
DOOR JAMB WITH
FLASHING
DETAIL #:
DATE:
AR-FO-03-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
FRAMED OPENING
(NOT BY KINGSPAN)
DOOR FRAME
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
SEALANT
FIELD CUT PANELS TO SUIT
2", 2.5", 3", O
R 4"
CONTINUOUS BUTYL SEALANT
1
4
" - 14 "LOW PROFILE" FASTENER
TWO PIECE JAMB
EXTRUSION
FLASHING TRIM
NOT BY KINGSPAN
HORIZONTAL SUPPORTS
NOT BY KINGSPAN
DOOR JAMB W/
EXTRUSION
DETAIL #:
DATE:
AR-FO-04-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
EXPOSED SEALANT
(NOT BY KINGSPAN)
WINDOW FRAME
(NOT BY KINGSPAN)
FIELD DRILL 1/4" Ø WEEP HOLES
(NOT BY KINGSPAN)
NOTE: 1) SEE FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS
STANDARD SOFFIT
EXTRUSION
1"
2", 2.5", 3", OR 4"
FRAMED OPENING
(NOT BY KINGSPAN)
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
HORIZONTAL SUPPORTS
NOT BY KINGSPAN
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
WINDOW HEAD WITH
EXTRUSION
DETAIL #:
DATE:
AR-FO-05-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
EXPOSED SEALANT
(NOT BY KINGSPAN)
WINDOW FRAME
(NOT BY KINGSPAN)
2) SEE FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS
2", 2.5", 3", OR 4"
TRIMLESS END
FRAMED OPENING
(NOT BY KINGSPAN)
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
HORIZONTAL SUPPORTS
NOT BY KINGSPAN
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
2-PC HEAD FLASHING
NON-SKINNING BUTYL
APPLIED BETWEEN
FLASHING PIECES
NOTE: 1) SEE DETAIL AR-TL-04-DW4H, AR-TL-05-DW4H, AR-TL-06-DW4H, AR-TL-07-DW4H
AND AR-TL-08-DW4H FOR TYPICAL TRIM LAP INSTRUCTIONS
WINDOW HEAD
W/FLASHING
DETAIL #:
DATE:
AR-FO-06-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
FIELD CUT PANELS TO SUIT
FRAMED OPENING
(NOT BY KINGSPAN)
WINDOW FRAME
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
TWO PIECE JAMB
EXTRUSION
NOTE: 1) SEE FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS
2", 2.5", 3", O
R 4"
FLASHING TRIM
NOT BY KINGSPAN
CONTINUOUS BUTYL SEALANT
SEALANT
1
4
" - 14 "LOW PROFILE" FASTENER
HORIZONTAL SUPPORTS
NOT BY KINGSPAN
WINDOW JAMB W/
EXTRUSION
DETAIL #:
DATE:
AR-FO-07-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
FIELD CUT PANELS TO SUIT
WINDOW FRAME
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
2", 2
.5
", 3
", O
R 4
"
1
4
" - 14 "LOW PROFILE" FASTENER
POP RIVETS
JAMB TRIM
SEALANT
FRAMED OPENING
(NOT BY KINGSPAN)
HORIZONTAL SUPPORTS
NOT BY KINGSPAN
NON-SKINNING BUTYL APPLIED
BETWEEN JAMB TRIM AND
JAMB MENDING PLATE
JAMB MENDING PLATE
CONTINUOUS BUTYL SEALANT
2) SEE FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS
NOTE: 1) SEE DETAIL AR-TL-04-DW4H, AR-TL-05-DW4H, AR-TL-06-DW4H, AR-TL-07-DW4H
AND AR-TL-08-DW4H FOR TYPICAL TRIM LAP INSTRUCTIONS
WINDOW JAMB W/
FLASHING
DETAIL #:
DATE:
AR-FO-08-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
OPTIONAL WIPER
GASKET
(FIELD INSTALLED)
NOTE: 1) SEE FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS
2", 2.5", 3", OR 4"
SEALANT
WINDOW FRAME
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
SILL EXTRUSION
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
HORIZONTAL SUPPORTS
NOT BY KINGSPAN
BREAK-FORMED 6"
SPLICE PLATE BED
SEALED IN SILICONE
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
SILL MENDING PLATE
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
NON-SKINNING BUTYL APPLIED
BETWEEN SILL EXTRUSION AND
SILL MENDING PLATE
WINDOW SILL W/
EXTRUSION
DETAIL #:
DATE:
AR-FO-09-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
2", 2.5", 3", OR 4"
SEALANT
WINDOW FRAME
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
EXTERIOR SILL TRIM
FRAMED OPENING
(NOT BY KINGSPAN)
HORIZONTAL SUPPORTS
NOT BY KINGSPAN
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
NON-SKINNING BUTYL APPLIED
BETWEEN SILL TRIM AND SILL
MENDING PLATE
SILL MENDING PLATE
2) SEE FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS
NOTE: 1) SEE DETAIL AR-TL-04-DW4H, AR-TL-05-DW4H, AR-TL-06-DW4H, AR-TL-07-DW4H
AND AR-TL-08-DW4H FOR TYPICAL TRIM LAP INSTRUCTIONS
WINDOW SILL W/
FLASHING
DETAIL #:
DATE:
AR-FO-10-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
EXTERIOR CAP TRIM
EXPOSED SEALANT
(NOT BY KINGSPAN)
FIELD CUT PANEL TO SUIT
FRAMED OPENING
(NOT BY KINGSPAN)
LOUVER UNIT
(NOT BY KINGSPAN)
POP RIVETS
2", 2.5", 3", OR 4"
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
HORIZONTAL SUPPORTS
NOT BY KINGSPAN
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
2-PC HEAD FLASHING
NON-SKINNING BUTYL
APPLIED BETWEEN
FLASHING PIECES
NOTE: 1) SEE DETAIL AR-TL-04-DW4H, AR-TL-05-DW4H, AR-TL-06-DW4H, AR-TL-07-DW4H
AND AR-TL-08-DW4H FOR TYPICAL TRIM LAP INSTRUCTIONS
LOUVER W/ FIELD CUT
HEAD
DETAIL #:
DATE:
AR-FO-11-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
LOUVER UNIT
(NOT BY KINGSPAN)
JAMB TRIM
FRAMED OPENING
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)
POP RIVETS
2", 2
.5
", 3
", O
R 4
"
1
4
" - 14 "LOW PROFILE" FASTENER
SEALANT
HORIZONTAL SUPPORTS
NOT BY KINGSPAN
FIELD CUT PANELS TO SUIT
NON-SKINNING BUTYL APPLIED
BETWEEN JAMB TRIM AND
JAMB MENDING PLATE
JAMB MENDING PLATE
CONTINUOUS BUTYL SEALANT
NOTE: 1) SEE DETAIL AR-TL-04-DW4H, AR-TL-05-DW4H, AR-TL-06-DW4H, AR-TL-07-DW4H
AND AR-TL-08-DW4H FOR TYPICAL TRIM LAP INSTRUCTIONS
LOUVER W/ FIELD CUT
JAMB
DETAIL #:
DATE:
AR-FO-12-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
EXTERIOR SILL TRIM
2", 2.5", 3", OR 4"
EXPOSED SEALANT
(NOT BY KINGSPAN)
FIELD CUT PANEL
TO SUIT
POP RIVETS
LOUVER UNIT
(NOT BY KINGSPAN)
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
FRAMED OPENING
(NOT BY KINGSPAN)
HORIZONTAL SUPPORTS
NOT BY KINGSPAN
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
NON-SKINNING BUTYL APPLIED
BETWEEN SILL TRIM AND SILL
MENDING PLATE
SILL MENDING PLATE
NOTE: 1) SEE DETAIL AR-TL-04-DW4H, AR-TL-05-DW4H, AR-TL-06-DW4H, AR-TL-07-DW4H
AND AR-TL-08-DW4H FOR TYPICAL TRIM LAP INSTRUCTIONS
LOUVER SILL W/ FIELD
CUT END
DETAIL #:
DATE:
AR-FO-13-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
STEEL FRAMING
BY OTHERS
ALUMINUM SOFFIT
EXTRUSION
1/4" DIA. WEEP HOLE @
24" O.C. FIELD DRILLED
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
1"
1
1
2
"
2", 2
1
2
", 3", or 4"
FIELD CUT 6" SPLICE PLATE
FROM SPLICE EXTRUSION
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
SOFFIT W/ EXTRUSION
DETAIL #:
DATE:
AR-SF-01-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
STEEL FRAMING
BY OTHERS
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
2", 2
1
2
", 3", or 4"
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
TRIMLESS END
POP RIVETS 12" O.C.
SEALANT
SOFFIT FLASHING
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
SOFFIT W/ FLASHING
DETAIL #:
DATE:
AR-SF-02-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
STEEL FRAMING
BY OTHERS
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
2", 2
1
2
", 3", or 4"
FACTORY TRANSVERSE BEND
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
SH
OR
T LE
G 6'-0 M
AX
IM
UM
, 14'-0 M
AX
IM
UM
P
AN
EL LE
NG
TH
TRANSVERSE BENT
SOFFIT
DETAIL #:
DATE:
AR-SF-03-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
FIELD CUT PANEL
TO SUIT CONDITION
SEALANT
GIRT LINE
3"
ENDWALL EXTRUSION
PART "B" CAP
2", 2
1
2
", 3", O
R 4"
ENDWALL EXTRUSION
PART "A" RECEIVER
1
4
" - 14 "LOW PROFILE" FASTENER
AT GIRTS
SEALANT
BUTYL SEALANT
END WALL W/
EXTRUSION
DETAIL #:
DATE:
AR-SF-04-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
FIELD CUT PANEL
TO SUIT CONDITION
SEALANT
GIRT LINE
2", 2
1
2
", 3", O
R 4"
1
4
" - 14 "LOW PROFILE" FASTENER
AT GIRTS
SEALANT
FORMED ENDWALL TRIM
POP RIVETS 12" O.C.
BUTYL SEALANT
INTERIOR MENDING PLATE
FASTEN TO LINER SHEET
END WALL W/
FLASHING
DETAIL #:
DATE:
AR-SF-05-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
SILICONE SEALANT &
BACKER ROD
ZERO PROFILE HORIZONTAL
JOINT FLASHING FOR
DRAINAGE
INSTALLER TO PLUG
TOPS OF VERTICAL
JOINTS WITH SEALANT
STEEL FRAMING
BY OTHERS
5" M
IN
. B
EA
RIN
G
DO NOT CAULK HERE
ALLOW TO DRAIN
5
8
"
2", 2
1
2
", 3", or 4"
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
MENDING PLATE WITH BUTYL
CAULKING TO UNDERSIDE OF
HORIZONTAL JOINT FLASHING
TRIMLESS STACK
JOINT
DETAIL #:
DATE:
AR-SJ-01-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
STEEL FRAMING
BY OTHERS
HORIZONTAL JOINT
EXTRUSION W/ WEEP
HOLES @ 24" O.C.
5" M
IN
. B
EA
RIN
G
3
1
4
"
1"
SEALANT
MENDING PLATE WITH
BUTYL CAULKING TO
UNDERSIDE OF EXTRUSION
2", 2
1
2
", 3", or 4"
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
BREAK-FORMED 6"
SPLICE PLATES BED
SEALED IN BUTYL
STACK JOINT W/
EXTRUSION
DETAIL #:
DATE:
AR-SJ-02-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
4"
STAINLESS STEEL SCREW
PAINTED TO MATCH
PANEL. 12" O.C.
FABRICATED METAL
FLASHING EXTENSION
SILICONE SEALANT
PARAPET COPING EXTRUSION
2", 2
1
2
", 3", or 4"
1"
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
FABRICATED METAL CLEAT
WITH SCREWS 12" O.C.
POP RIVETS 12" O.C.
MEMBRANE ROOF &
PARAPET BACKER
(NOT BY KINGSPAN)
SILICONE SEALANT
HORIZONTAL SUPPORTS
NOT BY KINGSPAN
BREAK-FORMED 6"
SPLICE PLATE BED
SEALED IN SILICONE
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
PARAPET COPING
DETAIL #:
DATE:
AR-PR-01-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
STAINLESS STEEL SCREW
PAINTED TO MATCH
PANEL. 12" O.C.
FABRICATED METAL
SPRING CLEAT
2", 2
1
2
", 3", or 4"
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
FABRICATED METAL HOOK
CLEAT WITH LOW PROFILE
SCREWS 12" O.C.
MEMBRANE ROOF &
PARAPET BACKER
(NOT BY KINGSPAN)
SILICONE SEALANT
FABRICATED METAL COPING
WITH BED SEALED INSIDE
SPLICE PLATES
HORIZONTAL SUPPORTS
NOT BY KINGSPAN
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
WRAP MEMBRANE (NOT BY KINGSPAN)
ADHERE TO EXTERIOR PANEL FACE
PARAPET W/ FLUSH
TRIM
DETAIL #:
DATE:
AR-PR-02-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
STAINLESS STEEL SCREW
PAINTED TO MATCH
PANEL. 12" O.C.
2", 2
1
2
", 3", or 4"
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
MEMBRANE ROOF &
PARAPET BACKER
(NOT BY KINGSPAN)
FABRICATED METAL COPING
WITH BED SEALED INSIDE
SPLICE PLATES
POP RIVETS 12" O.C.
HORIZONTAL SUPPORTS
NOT BY KINGSPAN
FASTENING CLIP WITH
(2)
1
4
"-14 HWH FASTENERS
*PER-DRILLING REQ'D*
WRAP MEMBRANE (NOT BY KINGSPAN)
ADHERE TO EXTERIOR PANEL FACE
PARAPET W/ PROFILED
TRIM
DETAIL #:
DATE:
AR-PR-03-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
SECTION 'A-A'
PENETRATION
(NOT BY KINGSPAN)
ELEVATION
BACKER ROD AND
SEALANT
(NOT BY KINGSPAN)
POP RIVET
'A'
TRIM
FASTENER
(AS REQUIRED)
'A'
PENETRATION
(NOT BY KINGSPAN)
BACKER ROD AND
SEALANT
(NOT BY KINGSPAN)
FLASHING
SEALANT
(NOT BY KINGSPAN)
SEALANT
(NOT BY KINGSPAN)
NOTES: 1. DO NOT ALIGN PENETRATIONS AT PANEL JOINT LOCATIONS.
2. FLASHING AT PENETRATIONS TO BE FIELD FABRICATED FROM
FLATSTOCK SHEETS AS NECESSARY
WALL PENETRATION
SECTION
DETAIL #:
DATE:
AR-TL-01-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
PIPE RING WITH SEALANT
NOT BY KINGSPAN
PIPE PENETRATION
INSULATION FILL
NOT BY KINGSPAN
FIELD CUT HOLE
IN PANEL FOR PIPE
PIPE PENETRATION
DETAIL #:
DATE:
AR-TL-02-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
FASTENER AS REQUIRED
SEALANT (NOT BY KINGSPAN)
FLASHING AS REQUIRED
INSULATION FILL
(NOT BY KINGSPAN)
SEALANT (NOT BY KINGSPAN)
SEALANT (NOT BY KINGSPAN)
FLASHING AS REQUIRED
F.I.P. INSULATION
(NOT BY KINGSPAN)
FASTENER AS REQUIRED
SEALANT (NOT BY KINGSPAN)
FASTENER AS REQUIRED
FASTENER AS REQUIRED
NOTE: FLASHING AT PIPE PENETRATIONS
TO BE FIELD FABRICATED FROM FLATSTOCK
SHEETS AS NECESSARY
NOTE: DO NOT ALIGN PENETRATIONS
AT PANEL JOINT LOCATIONS.
PENETRATION DETAIL
DETAIL #:
DATE:
AR-TL-03-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
M
I
N
.
3
"
T
R
I
M
L
A
P
M
I
N
.
3
"
T
R
I
M
L
A
P
(2) BEADS
BUTYL SEALANT
TRIM END LAP
DETAIL #:
DATE:
AR-TL-04-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
M
I
N
.
3
"
T
R
I
M
L
A
P
M
I
N
.
3
"
T
R
I
M
L
A
P
(2) BEADS
BUTYL SEALANT
FIELD NOTCH HEM(S)
AS REQUIRED
(NOT BY KINGSPAN)
TRIM LAP W/ HEM
DETAIL #:
DATE:
AR-TL-05-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
(2) BEADS
BUTYL SEALANT
(2) BEADS
BUTYL SEALANT
MIN
. 3"
TR
IM
LA
P
CARRY BUTYL SEALANT
ACROSS TOP TO PREVENT
WATER SIPHONING
MENDING PLATE W/
SHINGLE LAP
DETAIL #:
DATE:
AR-TL-06-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us6/25/21
(2) BEADS
BUTYL SEALANT
N
O
M
.
1
4
"
G
A
P
8" LONG LAP STRIP
TRIM END LAP WITH
LAP STRIP
DETAIL #:
DATE:
AR-TL-07-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
USE DUPONT
FLEXWRAP NF 6" x 6"
PATCH
JAMB MENDING PLATE
OR FLASHING LEG
BEHIND PANEL
SILL MENDING PLATE
BEHIND PANEL
4" LAP BED SEALED IN
BUTYL CAULK
1" TAB UP BED SEALED IN
BUTYL CAULK
4" LAP BED SEALED IN
BUTYL CAULK
1" TAB DOWN BED SEALED
IN BUTYL CAULK
HEAD FLASHING
PEFORM THIS WORK PRIOR
TO INSTALLING PANELS
USE DUPONT
FLEXWRAP NF 6" x 6"
PATCH
CARRY NON-SKINNING BUTYL
REAR SEAL CAULK OVER THE
FLEXWRAP NF TAPE
HEAD FLASHING LEG
BEHIND PANEL
TRIM AT FRAMED
OPENINGS
DETAIL #:
DATE:
AR-TL-08-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
2" PANEL ENDWALL
EXTRUSION RECEIVER
DIE #11487
ENDWALL EXTRUSION CAP
6" SPLICE PLATE DIE
#13262
2" PANEL BASE
EXTRUSION DIE #11372
CAP DIE #11488
2" PANEL SOFFIT
EXTRUSION DIE #11423
2" PANEL HORIZONTAL
JOINT EXTRUSION DIE
#11298
PARAPET EXTRUSION
DIE # 13938
SILL EXTRUSION
DIE #13937
OUTSIDE CORNER
EXTRUSION
RECEIVER DIE
#13264
2" OUTSIDE CORNER
EXTRUSION CAP DIE
#13263
2" EXTRUSION
DETAIL #:
DATE:
AR-TL-09-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
INSIDE CORNER
EXTRUSION
RECEIVER DIE
#14298
2" INSIDE CORNER
EXTRUSION CAP
DIE #15693
2" EXTRUSION
DETAIL #:
DATE:
AR-TL-10-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
PARAPET EXTRUSION
SILL EXTRUSION
DIE #13937
DIE # 13938
2.5" TWO PIECE
ENDWALL/JAMB
EXTRUSION RECEIVER
DIE #16010
TWO PIECE
ENDWALL/JAMB
EXTRUSION CAP
DIE #11488
2.5" OUTSIDE CORNER
EXTRUSION RECEIVER
DIE #16006
BASE EXTRUSION
DIE # 16009
2.5" STANDARD SOFFIT
EXTRUSION DIE #16004
6" SPLICE PLATE DIE
#16003
2.5" PANEL HORIZONTAL
JOINT EXTRUSION DIE
#16005
2.5" EXTRUSION
DETAIL #:
DATE:
AR-TL-11-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
ENDWALL EXTRUSION CAP
3" PANEL BASE
EXTRUSION DIE #11366
3" PANEL ENDWALL
EXTRUSION RECEIVER
DIE #12714
CAP DIE #11488
3" PANEL HORIZONTAL
JOINT EXTRUSION DIE
#12861
3" STANDARD SOFFIT EXTRUSION
DIE #13789
PARAPET EXTRUSION
DIE # 13938
SILL EXTRUSION
DIE #13937
INSIDE CORNER
EXTRUSION
RECEIVER DIE
#14298
3" INSIDE CORNER
EXTRUSION CAP
DIE #14299
3" OUTSIDE CORNER
EXTRUSION
RECEIVER DIE #16017
3" OUTSIDE CORNER
EXTRUSION CAP DIE
#14108
6" SPLICE PLATE DIE
#13862
3" EXTRUSION
DETAIL #:
DATE:
AR-TL-12-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
4" OUTSIDE CORNER
EXTRUSION CAP
DIE #14109
PARAPET EXTRUSION
4" OUTSIDE CORNER
EXTRUSION RECEIVER
DIE #16016
SILL EXTRUSION
DIE #13937
DIE # 13938
TWO PIECE
ENDWALL/JAMB
EXTRUSION CAP
DIE #11488
4" TWO PIECE
ENDWALL/JAMB
EXTRUSION RECEIVER
DIE #16014
4" STANDARD BASE
EXTRUSION DIE #16011
4" STANDARD SOFFIT
EXTRUSION DIE #16012
6" SPLICE PLATE DIE
#16013
4" PANEL HORIZONTAL
JOINT EXTRUSION DIE
#16015
4" EXTRUSION
DETAIL #:
DATE:
AR-TL-13-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21
LAP STRIPS FOR OUTSIDE CORNER
LAP STRIP FOR PARAPET EXTRUSION
LAP STRIP FOR BASE EXTRUSION
LAP STRIPS FOR INSIDE CORNER
EXTRUSIONEXTRUSION
JAMB EXTRUSION
LAP STRIP FOR TWO PIECE
LAP STRIP FOR SOFFIT EXTRUSION
EXTRUSION LAP
STRIPS
DETAIL #:
DATE:
AR-TL-14-DW4V
DW-4000 - VERTICAL INSTALLATION
www.kingspanpanels.ca
C:\Users\adam.rinder\Documents\BENCHMARK\Kingspan Benchmark Logo_RGB.bmp
www.kingspanpanels.us
6/25/21