DRAFT 3 bed, 2 bath Dwelling type: Date of assessment: Produced by: Total floor area: House, End-Terrace 15/08/2019 Michael Brogden 84.64 m² This document is a Predicted Energy Assessment for properties marketed when they are incomplete. It includes a predicted energy rating which might not represent the final energy rating of the property on completion. Once the property is completed, this rating will be updated and an official Energy Performance Certificate will be created for the property. This will include more detailed information about the energy performance of the completed property. The energy performance has been assessed using the Government approved SAP2012 methodology and is rated in terms of the energy use per square meter of floor area; the energy efficiency is based on fuel costs and the environmental impact is based on carbon dioxide (CO 2 ) emissions. The energy efficiency rating is a measure of the overall efficiency of a home. The higher the rating the more energy efficient the home is and the lower the fuel bills are likely to be. The environmental impact rating is a measure of a home's impact on the environment in terms of carbon dioxide (CO 2 ) emissions. The higher the rating the less impact it has on the environment. Energy Efficiency Rating Very energy efficient - lower running costs A B C D E F G Not energy efficient - higher running costs (92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) 84 EU Directive 2002/91/EC England EU Directive 2002/91/EC England 87 Environmental Impact (CO 2 ) Rating Very environmentally friendly - lower CO 2 emissions A B C D E F G Not environmentally friendly - higher CO 2 emissions (92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) PREDICTED ENERGY ASSESSMENT Page 1 of 41 Regs Region: England Elmhurst Energy Systems SAP2012 Calculator (Design System) version 4.10r08 This report has not been submiƩed through the Elmhurst Energy members’ portal, therefore results are subject to change when the dwelling is completed.

Upload: others

Post on 15-Feb-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • DRAF

    T3 bed,2 bath

    Dwelling type: Date of assessment:Produced by: Total floor area:

    House, End-Terrace15/08/2019Michael Brogden84.64 m²

    This document is a Predicted Energy Assessment for properties marketed when they are incomplete. Itincludes a predicted energy rating which might not represent the final energy rating of the property oncompletion. Once the property is completed, this rating will be updated and an official Energy PerformanceCertificate will be created for the property. This will include more detailed information about the energyperformance of the completed property.

    The energy performance has been assessed using the Government approved SAP2012 methodology andis rated in terms of the energy use per square meter of floor area; the energy efficiency is based on fuelcosts and the environmental impact is based on carbon dioxide (CO2) emissions.

    The energy efficiency rating is a measure of theoverall efficiency of a home. The higher the ratingthe more energy efficient the home is and the lowerthe fuel bills are likely to be.

    The environmental impact rating is a measure of ahome's impact on the environment in terms ofcarbon dioxide (CO2) emissions. The higher therating the less impact it has on the environment.

    Energy Efficiency Rating

    Very energy efficient - lower running costs

    AB

    CD

    EF

    GNot energy efficient - higher running costs

    (92 plus)

    (81-91)

    (69-80)

    (55-68)

    (39-54)

    (21-38)

    (1-20)

    84

    EU Directive2002/91/ECEngland

    EU Directive2002/91/ECEngland

    87

    Environmental Impact (CO2) Rating

    Very environmentally friendly - lower CO2 emissions

    AB

    CD

    EF

    GNot environmentally friendly - higher CO2 emissions

    (92 plus)

    (81-91)

    (69-80)

    (55-68)

    (39-54)

    (21-38)

    (1-20)

    PREDICTED ENERGY ASSESSMENT

    Page 1 of 41

    Regs Region: EnglandElmhurst Energy Systems SAP2012 Calculator (Design System) version 4.10r08

    This report has not been submi ed through the Elmhurst Energy members’ portal, therefore results are subject to change when the dwelling is completed.

  • DRAF

    TSUMARY FOR INPUT DATA FOR New Build (As Designed)Target Carbon Dioxide Emission Rate (TER) 17.90 kgCO₂/m²Fuel factor 1.00 (mains gas)Fuel for main hea ng Mains gas

    1a TER and DER

    -0.65 (-3.6%) kgCO₂/m²Dwelling Carbon Dioxide Emission Rate (DER) 17.25 Pass kgCO₂/m²

    49.71Target Fabric Energy E ciency (TFEE) kWh/m²/yrDwelling Fabric Energy E ciency (DFEE) 46.07 kWh/m²/yr

    1b TFEE and DFEE

    Property ReferenceAssessment Reference

    15/08/2019Type 52 END

    Issued on DateProp Type Ref

    DE-17114 Plot 016 OPPLOT 16

    Property 3 bed, 2 bath

    7.34

    3.64

    % DFEE

  • DRAF

    TParty wall U-value 0.00 W/m²KRoof U-value 0.10 W/m²K

    10 Key features

    9 Summer me temperature

    Overhea ng risk (Severn Valley) Not signi cant PassBased on:

    Overshading AverageWindows facing North EastWindows facing South West

    6.22 m², No overhang4.91 m², No overhang

    Air change rate 4.00 achBlinds/curtains Dark-coloured curtain or roller blind, closed 100% of daylight

    hours

    Main hea ng system Boiler system with radiators or under oor - Mains gasData from databaseIdeal LOGIC COMBI ESP1 35Combi boilerE ciency: 89.6% SEDBUK2009Minimum: 88.0%

    Pass

    Secondary hea ng system None

    5 Cylinder insula on

    Hot water storage No cylinder

    6 Controls

    Percentage of xed lights with low-energy ngs

    100 %

    Minimum 75 Pass %

    7 Low energy lights

    Space hea ng controls Time and temperature zone control PassHot water controls No cylinderBoiler interlock Yes Pass

    8 Mechanical ven la on

    Not applicable

    3 Air permeability

    Air permeability at 50 pascals 5.00 (design value) m³/(h.m²) @ 50 PaMaximum 10.0 Pass m³/(h.m²) @ 50 Pa

    Criterion 3 – Limi ng the e ects of heat gains in summer

    Criterion 4 – Building performance consistent with DER and DFEE rate

    Party Walls

    Air permeability and pressure tes ng

    Filled Cavity with Edge Sealing 0.00 Pass W/m²KType U-value

    BUILDING REGULATION COMPLIANCE Calcula on Type: New Build (As Designed)

    Page 3 of 41

    Regs Region: EnglandElmhurst Energy Systems SAP2012 Calculator (Design System) version 4.10r08

    This report has not been submi ed through the Elmhurst Energy members’ portal, therefore results are subject to change when the dwelling is completed.

  • Junc on detail SourceTypePsi

    (W/mK)Length

    (m) Result Reference

    External wall E2 Other lintels (including other steel lintels)Independently

    assessed 0.211 9.30 1.96 CATNIC

    External wall E3 Sill Table K1 - Approved 0.040 7.28 0.29External wall E4 Jamb Table K1 - Approved 0.050 23.10 1.16

    External wall E5 Ground oor (normal) Independently assessed 0.085 18.40 1.56

    External wall E6 Intermediate oor within a dwelling Independently assessed 0.004 18.40 0.07E06-CXBR-

    CW4040_100mm-01

    External wall E10 Eaves (insula on at ceiling level) Table K1 - Approved 0.060 9.20 0.55

    External wall E12 Gable (insula on at ceiling level) Independently assessed 0.080 9.20 0.74E12-CXBR-

    CW4040_100mm-01

    External wall E16 Corner (normal) Independently assessed 0.042 9.74 0.41E16-CXBR-

    CW4040_100mm-01

    External wall E18 Party wall between dwellings Independently assessed 0.052 9.74 0.51E18-CXBR-

    CW4040_100mm-01-RD22

    Party wall P1 Party wall - Ground oor Independently assessed 0.011 9.20 0.10

    Party wall P2 Party wall - Intermediate oor within a dwelling Table K1 - Default 0.000 9.20 0.00

    Party wall P4 Party wall - Roof (insula on at ceiling level)Independently

    assessed 0.117 9.20 1.08P04-CXBR-EWM22-

    Spand

    0.0488.43

    Y-Value:Total: W/mK:

    W/m²K:

    7.34

    3.64

    % DFEE

  • 7.34

    3.64

    % DFEE

  • REGULATIONS COMPLIANCE REPORT - Approved Document L1A, 2013 Edi on, England

    ----------------------------------------------------------------------------------------------------REGULATIONS COMPLIANCE REPORT - Approved Document L1A, 2013 Edition, England----------------------------------------------------------------------------------------------------

    DWELLING AS DESIGNED

    End-Terrace House, total floor area 85 m²

    This report covers items included within the SAP calculations.It is not a complete report of regulations compliance.----------------------------------------------------------------------------------------------------1a TER and DERFuel for main heating:Mains gasFuel factor:1.00 (mains gas)Target Carbon Dioxide Emission Rate (TER) 17.90 kgCO /m²Dwelling Carbon Dioxide Emission Rate (DER) 17.25 kgCO /m²OK----------------------------------------------------------------------------------------------------1b TFEE and DFEETarget Fabric Energy Efficiency (TFEE)49.7 kWh/m²/yrDwelling Fabric Energy Efficiency (DFEE)46.1 kWh/m²/yrOK----------------------------------------------------------------------------------------------------2 Fabric U-valuesElement Average Highest External wall 0.27 (max. 0.30) 0.27 (max. 0.70) OKParty wall 0.00 (max. 0.20) - OKFloor 0.15 (max. 0.25) 0.15 (max. 0.70) OKRoof 0.10 (max. 0.20) 0.10 (max. 0.35) OKOpenings 1.38 (max. 2.00) 1.41 (max. 3.30) OK----------------------------------------------------------------------------------------------------2a Thermal bridgingThermal bridging calculated from linear thermal transmittances for each junction ----------------------------------------------------------------------------------------------------3 Air permeabilityAir permeability at 50 pascals: 5.00 (design value) Maximum 10.0 OK----------------------------------------------------------------------------------------------------4 Heating efficiencyMain heating system: Boiler system with radiators or underfloor - Mains gasData from databaseIdeal LOGIC COMBI ESP1 35Combi boilerEfficiency: 89.6% SEDBUK2009Minimum: 88.0% OK

    Secondary heating system: None ----------------------------------------------------------------------------------------------------5 Cylinder insulationHot water storage No cylinder ----------------------------------------------------------------------------------------------------6 ControlsSpace heating controls: Time and temperature zone control OK

    Hot water controls: No cylinder

    Boiler interlock Yes OK----------------------------------------------------------------------------------------------------7 Low energy lightsPercentage of fixed lights with low-energy fittings:100% Minimum 75% OK----------------------------------------------------------------------------------------------------8 Mechanical ventilationNot applicable ----------------------------------------------------------------------------------------------------9 Summertime temperatureOverheating risk (Severn Valley): Not significant OKBased on:Overshading: Average Windows facing North East: 6.22 m², No overhangWindows facing South West: 4.91 m², No overhang Air change rate: 4.00 ach Blinds/curtains: Dark-coloured curtain or roller blind, closed 100% of daylight hours----------------------------------------------------------------------------------------------------10 Key featuresParty wall U-value 0.00 W/m²K Roof U-value 0.10 W/m²K

    ----------------------------------------------------------------------------------------------------

    FULL SAP CALCULATION PRINTOUT Calcula on Type: New Build (As Designed)

    Page 6 of 41

    Regs Region: EnglandElmhurst Energy Systems SAP2012 Calculator (Design System) version 4.10r08

  • CALCULATION OF DWELLING EMISSIONS FOR REGULATIONS COMPLIANCE 09 Jan 2014

    ----------------------------------------------------------------------------------------------------SAP 2012 WORKSHEET FOR New Build (As Designed) (Version 9.92, January 2014)CALCULATION OF DWELLING EMISSIONS FOR REGULATIONS COMPLIANCE 09 Jan 2014--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

    ----------------------------------------------------------------------------------------------------1. Overall dwelling dimensions---------------------------------------------------------------------------------------------------- Area Storey height Volume (m2) (m) (m3)Ground floor 42.3200 (1b) x 2.3100 (2b) = 97.7592 (1b) - (3b)First floor 42.3200 (1c) x 2.5600 (2c) = 108.3392 (1c) - (3c)Total floor area TFA = (1a)+(1b)+(1c)+(1d)+(1e)...(1n) 84.6400 (4)Dwelling volume (3a)+(3b)+(3c)+(3d)+(3e)...(3n) = 206.0984 (5)

    ----------------------------------------------------------------------------------------------------2. Ventilation rate---------------------------------------------------------------------------------------------------- main secondary other total m3 per hour heating heating Number of chimneys 0 + 0 + 0 = 0 * 40 = 0.0000 (6a)Number of open flues 0 + 0 + 0 = 0 * 20 = 0.0000 (6b)Number of intermittent fans 3 * 10 = 30.0000 (7a)Number of passive vents 0 * 10 = 0.0000 (7b)Number of flueless gas fires 0 * 40 = 0.0000 (7c)

    Air changes per hourInfiltration due to chimneys, flues and fans = (6a)+(6b)+(7a)+(7b)+(7c) = 30.0000 / (5) = 0.1456 (8)Pressure test YesMeasured/design AP50 5.0000Infiltration rate 0.3956 (18)Number of sides sheltered 2 (19)

    Shelter factor (20) = 1 - [0.075 x (19)] = 0.8500 (20)Infiltration rate adjusted to include shelter factor (21) = (18) x (20) = 0.3362 (21)

    Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Wind speed 5.1000 5.0000 4.9000 4.4000 4.3000 3.8000 3.8000 3.7000 4.0000 4.3000 4.5000 4.7000 (22)Wind factor 1.2750 1.2500 1.2250 1.1000 1.0750 0.9500 0.9500 0.9250 1.0000 1.0750 1.1250 1.1750 (22a)Adj infilt rate 0.4287 0.4203 0.4119 0.3699 0.3614 0.3194 0.3194 0.3110 0.3362 0.3614 0.3783 0.3951 (22b)Effective ac 0.5919 0.5883 0.5848 0.5684 0.5653 0.5510 0.5510 0.5484 0.5565 0.5653 0.5715 0.5780 (25)

    ----------------------------------------------------------------------------------------------------3. Heat losses and heat loss parameter----------------------------------------------------------------------------------------------------Element Gross Openings NetArea U-value A x U K-value A x K m2 m2 m2 W/m2K W/K kJ/m2K kJ/KFrench Door (Uw = 1.41) 2.1200 1.3347 2.8296 (27)Window (Uw = 1.41) 9.0100 1.3347 12.0258 (27)Solid door tall window 2.1200 1.2000 2.5440 (26)Heat Loss Floor 1 42.3200 0.1500 6.3480 110.0000 4655.2000 (28a)External Wall 1 89.6100 13.2500 76.3600 0.2700 20.6172 60.0000 4581.6000 (29a)External Roof 1 42.3200 42.3200 0.1000 4.2320 9.0000 380.8800 (30)Total net area of external elements Aum(A, m2) 174.2500 (31)Fabric heat loss, W/K = Sum (A x U) (26)...(30) + (32) = 48.5967 (33)Party Wall 1 44.8000 0.0000 0.0000 110.0000 4928.0000 (32)Internal Wall 1 120.2700 9.0000 1082.4300 (32c)Internal Wall 2 14.7600 62.7000 925.4520 (32c)floor 42.3200 18.0000 761.7600 (32d)Internal Ceiling 1 42.3200 18.0000 761.7600 (32e)

    Heat capacity Cm = Sum(A x k) (28)...(30) + (32) + (32a)...(32e) = 18077.0820 (34)Thermal mass parameter (TMP = Cm / TFA) in kJ/m2K 213.5761 (35)Thermal bridges (Sum(L x Psi) calculated using Appendix K) 8.4273 (36)Total fabric heat loss (33) + (36) = 57.0239 (37)

    Ventilation heat loss calculated monthly (38)m = 0.33 x (25)m x (5) Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec (38)m 40.2557 40.0131 39.7752 38.6579 38.4489 37.4758 37.4758 37.2956 37.8506 38.4489 38.8718 39.3139 (38)Heat transfer coeff 97.2796 97.0370 96.7991 95.6818 95.4728 94.4997 94.4997 94.3195 94.8745 95.4728 95.8957 96.3378 (39)Average = Sum(39)m / 12 = 95.6808 (39)

    Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec HLP 1.1493 1.1465 1.1437 1.1305 1.1280 1.1165 1.1165 1.1144 1.1209 1.1280 1.1330 1.1382 (40)HLP (average) 1.1304 (40)Days in month 31 28 31 30 31 30 31 31 30 31 30 31 (41)

    ----------------------------------------------------------------------------------------------------4. Water heating energy requirements (kWh/year)----------------------------------------------------------------------------------------------------Assumed occupancy 2.5450 (42)Average daily hot water use (litres/day) 94.6445 (43)

    Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Daily hot water use 104.1089 100.3232 96.5374 92.7516 88.9658 85.1800 85.1800 88.9658 92.7516 96.5374 100.3232 104.1089 (44)Energy conte 154.3906 135.0310 139.3399 121.4799 116.5628 100.5849 93.2067 106.9560 108.2334 126.1356 137.6869 149.5190 (45)

    FULL SAP CALCULATION PRINTOUT Calcula on Type: New Build (As Designed)

    Page 7 of 41

    Regs Region: EnglandElmhurst Energy Systems SAP2012 Calculator (Design System) version 4.10r08

  • CALCULATION OF DWELLING EMISSIONS FOR REGULATIONS COMPLIANCE 09 Jan 2014

    Energy content (annual) Total = Sum(45)m = 1489.1265 (45)Distribution loss (46)m = 0.15 x (45)m 23.1586 20.2546 20.9010 18.2220 17.4844 15.0877 13.9810 16.0434 16.2350 18.9203 20.6530 22.4279 (46)Water storage loss:Total storage loss 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 (56)If cylinder contains dedicated solar storage 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 (57)Combi loss 14.1271 12.7494 14.0794 13.5832 14.0054 13.5184 13.9471 13.9849 13.5537 14.0488 13.6432 14.1154 (61)Total heat required for water heating calculated for each month 168.5177 147.7803 153.4193 135.0631 130.5683 114.1033 107.1538 120.9409 121.7871 140.1844 151.3301 163.6344 (62)Solar input 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 (63) Solar input (sum of months) = Sum(63)m = 0.0000 (63)Output from w/h 168.5177 147.7803 153.4193 135.0631 130.5683 114.1033 107.1538 120.9409 121.7871 140.1844 151.3301 163.6344 (64) Total per year (kWh/year) = Sum(64)m = 1654.4826 (64)Heat gains from water heating, kWh/month 54.8666 48.0851 49.8504 43.7879 42.2585 36.8241 34.4780 39.0591 39.3760 45.4523 49.1917 53.2439 (65)

    ----------------------------------------------------------------------------------------------------5. Internal gains (see Table 5 and 5a)----------------------------------------------------------------------------------------------------Metabolic gains (Table 5), Watts Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec (66)m 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 (66)Lighting gains (calculated in Appendix L, equation L9 or L9a), also see Table 5 22.1924 19.7111 16.0301 12.1358 9.0717 7.6587 8.2755 10.7568 14.4377 18.3320 21.3962 22.8091 (67)Appliances gains (calculated in Appendix L, equation L13 or L13a), also see Table 5 228.8645 231.2394 225.2547 212.5141 196.4313 181.3158 171.2177 168.8428 174.8274 187.5681 203.6508 218.7664 (68)Cooking gains (calculated in Appendix L, equation L15 or L15a), also see Table 5 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 (69)Pumps, fans 3.0000 3.0000 3.0000 3.0000 3.0000 3.0000 3.0000 3.0000 3.0000 3.0000 3.0000 3.0000 (70)Losses e.g. evaporation (negative values) (Table 5) -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 (71)Water heating gains (Table 5) 73.7455 71.5553 67.0032 60.8165 56.7991 51.1445 46.3414 52.4988 54.6889 61.0918 68.3218 71.5644 (72)Total internal gains 388.9778 386.6812 372.4634 349.6418 326.4775 304.2945 290.0100 296.2738 308.1296 331.1673 357.5443 377.3154 (73)

    ----------------------------------------------------------------------------------------------------6. Solar gains----------------------------------------------------------------------------------------------------

    [Jan] Area Solar flux g FF Access Gains m2 Table 6a Specific data Specific data factor W W/m2 or Table 6b or Table 6c Table 6d ----------------------------------------------------------------------------------------------------Northeast 2.1200 11.2829 0.7100 0.7000 0.7700 8.2385 (75)Northeast 4.1000 11.2829 0.7100 0.7000 0.7700 15.9329 (75)Southwest 4.9100 36.7938 0.7100 0.7000 0.7700 62.2223 (79)----------------------------------------------------------------------------------------------------

    Solar gains 86.3937 155.1893 233.6626 325.2647 396.9503 408.4312 387.7988 332.1241 265.0388 177.2672 104.9419 72.9889 (83)Total gains 475.3715 541.8704 606.1260 674.9065 723.4278 712.7256 677.8088 628.3979 573.1684 508.4345 462.4862 450.3043 (84)

    ----------------------------------------------------------------------------------------------------7. Mean internal temperature (heating season)----------------------------------------------------------------------------------------------------Temperature during heating periods in the living area from Table 9, Th1 (C) 21.0000 (85)Utilisation factor for gains for living area, ni1,m (see Table 9a) Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec tau 51.6183 51.7474 51.8746 52.4803 52.5952 53.1368 53.1368 53.2383 52.9269 52.5952 52.3633 52.1230alpha 4.4412 4.4498 4.4583 4.4987 4.5063 4.5425 4.5425 4.5492 4.5285 4.5063 4.4909 4.4749util living area 0.9970 0.9941 0.9864 0.9612 0.8912 0.7466 0.5858 0.6450 0.8690 0.9755 0.9944 0.9976 (86)

    MIT 19.5569 19.7154 19.9883 20.3591 20.6937 20.9082 20.9764 20.9639 20.8025 20.3740 19.9013 19.5302 (87)Th 2 19.9607 19.9631 19.9653 19.9760 19.9780 19.9874 19.9874 19.9891 19.9838 19.9780 19.9740 19.9698 (88)util rest of house 0.9961 0.9924 0.9821 0.9479 0.8526 0.6619 0.4639 0.5233 0.8081 0.9647 0.9924 0.9969 (89)MIT 2 18.0320 18.2648 18.6630 19.2015 19.6579 19.9183 19.9769 19.9712 19.8082 19.2310 18.5444 17.9991 (90)Living area fraction fLA = Living area / (4) = 0.2407 (91)MIT 18.3990 18.6139 18.9819 19.4801 19.9072 20.1566 20.2174 20.2101 20.0475 19.5061 18.8710 18.3676 (92)Temperature adjustment -0.1500adjusted MIT 18.2490 18.4639 18.8319 19.3301 19.7572 20.0066 20.0674 20.0601 19.8975 19.3561 18.7210 18.2176 (93)

    ----------------------------------------------------------------------------------------------------8. Space heating requirement ----------------------------------------------------------------------------------------------------

    Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Utilisation 0.9938 0.9886 0.9754 0.9369 0.8426 0.6637 0.4741 0.5325 0.8018 0.9554 0.9886 0.9951 (94)Useful gains 472.4335 535.6778 591.2200 632.3522 609.5473 473.0431 321.3252 334.6429 459.5932 485.7788 457.2324 448.0961 (95)Ext temp. 4.3000 4.9000 6.5000 8.9000 11.7000 14.6000 16.6000 16.4000 14.1000 10.6000 7.1000 4.2000 (96)Heat loss rate W 1356.9532 1316.2021 1193.7205 997.9708 769.2395 510.9188 327.6705 345.2215 550.0342 835.9698 1114.4005 1350.4260 (97)Month fracti 1.0000 1.0000 1.0000 1.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000 1.0000 1.0000 (97a)Space heating kWh 658.0827 524.5123 448.2604 263.2454 118.8110 0.0000 0.0000 0.0000 0.0000 260.5421 473.1611 671.3335 (98)Space heating 3417.9484 (98)Space heating per m2 (98) / (4) = 40.3822 (99)

    ----------------------------------------------------------------------------------------------------

    FULL SAP CALCULATION PRINTOUT Calcula on Type: New Build (As Designed)

    Page 8 of 41

    Regs Region: EnglandElmhurst Energy Systems SAP2012 Calculator (Design System) version 4.10r08

  • CALCULATION OF DWELLING EMISSIONS FOR REGULATIONS COMPLIANCE 09 Jan 2014

    8c. Space cooling requirement----------------------------------------------------------------------------------------------------Not applicable

    ----------------------------------------------------------------------------------------------------9a. Energy requirements - Individual heating systems, including micro-CHP----------------------------------------------------------------------------------------------------Fraction of space heat from secondary/supplementary system (Table 11) 0.0000 (201)Fraction of space heat from main system(s) 1.0000 (202)Efficiency of main space heating system 1 (in %) 90.5000 (206)Efficiency of secondary/supplementary heating system, % 0.0000 (208)Space heating requirement 3776.7386 (211)

    Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Space heating requirement 658.0827 524.5123 448.2604 263.2454 118.8110 0.0000 0.0000 0.0000 0.0000 260.5421 473.1611 671.3335 (98)Space heating efficiency (main heating system 1) 90.5000 90.5000 90.5000 90.5000 90.5000 0.0000 0.0000 0.0000 0.0000 90.5000 90.5000 90.5000 (210)Space heating fuel (main heating system) 727.1632 579.5717 495.3153 290.8788 131.2829 0.0000 0.0000 0.0000 0.0000 287.8919 522.8299 741.8049 (211)Water heating requirement 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 (215)

    Water heatingWater heating requirement 168.5177 147.7803 153.4193 135.0631 130.5683 114.1033 107.1538 120.9409 121.7871 140.1844 151.3301 163.6344 (64)Efficiency of water heater 87.3000 (216)(217)m 89.8287 89.7766 89.6620 89.3889 88.7959 87.3000 87.3000 87.3000 87.3000 89.3542 89.7032 89.8545 (217)Fuel for water heating, kWh/month 187.5989 164.6089 171.1085 151.0960 147.0432 130.7025 122.7420 138.5349 139.5042 156.8862 168.7009 182.1104 (219)Water heating fuel used 1860.6363 (219)Annual totals kWh/yearSpace heating fuel - main system 3776.7386 (211)Space heating fuel - secondary 0.0000 (215)

    Electricity for pumps and fans: central heating pump 30.0000 (230c) main heating flue fan 45.0000 (230e)Total electricity for the above, kWh/year 75.0000 (231)Electricity for lighting (calculated in Appendix L) 391.9239 (232)Total delivered energy for all uses 6104.2988 (238)

    ----------------------------------------------------------------------------------------------------12a. Carbon dioxide emissions - Individual heating systems including micro-CHP---------------------------------------------------------------------------------------------------- Energy Emission factor Emissions kWh/year kg CO2/kWh kg CO2/yearSpace heating - main system 1 3776.7386 0.2160 815.7755 (261)Space heating - secondary 0.0000 0.0000 0.0000 (263)Water heating (other fuel) 1860.6363 0.2160 401.8975 (264)Space and water heating 1217.6730 (265)Pumps and fans 75.0000 0.5190 38.9250 (267)Energy for lighting 391.9239 0.5190 203.4085 (268)Total CO2, kg/year 1460.0065 (272)Dwelling Carbon Dioxide Emission Rate (DER) 17.2500 (273)

    16 CO2 EMISSIONS ASSOCIATED WITH APPLIANCES AND COOKING AND SITE-WIDE ELECTRICITY GENERATION TECHNOLOGIESDER 17.2500 ZC1Total Floor Area TFA 84.6400Assumed number of occupants N 2.5450CO2 emission factor in Table 12 for electricity displaced from grid EF 0.5190CO2 emissions from appliances, equation (L14) 16.0232 ZC2CO2 emissions from cooking, equation (L16) 2.1276 ZC3Total CO2 emissions 35.4008 ZC4Residual CO2 emissions offset from biofuel CHP 0.0000 ZC5Additional allowable electricity generation, kWh/m²/year 0.0000 ZC6Resulting CO2 emissions offset from additional allowable electricity generation 0.0000 ZC7Net CO2 emissions 35.4008 ZC8

    ----------------------------------------------------------------------------------------------------

    FULL SAP CALCULATION PRINTOUT Calcula on Type: New Build (As Designed)

    Page 9 of 41

    Regs Region: EnglandElmhurst Energy Systems SAP2012 Calculator (Design System) version 4.10r08

  • CALCULATION OF TARGET EMISSIONS 09 Jan 2014

    ----------------------------------------------------------------------------------------------------SAP 2012 WORKSHEET FOR New Build (As Designed) (Version 9.92, January 2014)CALCULATION OF TARGET EMISSIONS 09 Jan 2014--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

    ----------------------------------------------------------------------------------------------------1. Overall dwelling dimensions---------------------------------------------------------------------------------------------------- Area Storey height Volume (m2) (m) (m3)Ground floor 42.3200 (1b) x 2.3100 (2b) = 97.7592 (1b) - (3b)First floor 42.3200 (1c) x 2.5600 (2c) = 108.3392 (1c) - (3c)Total floor area TFA = (1a)+(1b)+(1c)+(1d)+(1e)...(1n) 84.6400 (4)Dwelling volume (3a)+(3b)+(3c)+(3d)+(3e)...(3n) = 206.0984 (5)

    ----------------------------------------------------------------------------------------------------2. Ventilation rate---------------------------------------------------------------------------------------------------- main secondary other total m3 per hour heating heating Number of chimneys 0 + 0 + 0 = 0 * 40 = 0.0000 (6a)Number of open flues 0 + 0 + 0 = 0 * 20 = 0.0000 (6b)Number of intermittent fans 3 * 10 = 30.0000 (7a)Number of passive vents 0 * 10 = 0.0000 (7b)Number of flueless gas fires 0 * 40 = 0.0000 (7c)

    Air changes per hourInfiltration due to chimneys, flues and fans = (6a)+(6b)+(7a)+(7b)+(7c) = 30.0000 / (5) = 0.1456 (8)Pressure test YesMeasured/design AP50 5.0000Infiltration rate 0.3956 (18)Number of sides sheltered 2 (19)

    Shelter factor (20) = 1 - [0.075 x (19)] = 0.8500 (20)Infiltration rate adjusted to include shelter factor (21) = (18) x (20) = 0.3362 (21)

    Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Wind speed 5.1000 5.0000 4.9000 4.4000 4.3000 3.8000 3.8000 3.7000 4.0000 4.3000 4.5000 4.7000 (22)Wind factor 1.2750 1.2500 1.2250 1.1000 1.0750 0.9500 0.9500 0.9250 1.0000 1.0750 1.1250 1.1750 (22a)Adj infilt rate 0.4287 0.4203 0.4119 0.3699 0.3614 0.3194 0.3194 0.3110 0.3362 0.3614 0.3783 0.3951 (22b)Effective ac 0.5919 0.5883 0.5848 0.5684 0.5653 0.5510 0.5510 0.5484 0.5565 0.5653 0.5715 0.5780 (25)

    ----------------------------------------------------------------------------------------------------3. Heat losses and heat loss parameter----------------------------------------------------------------------------------------------------Element Gross Openings NetArea U-value A x U K-value A x K m2 m2 m2 W/m2K W/K kJ/m2K kJ/KTER Opaque door 2.1200 1.0000 2.1200 (26)TER Opening Type (Uw = 1.40) 11.1300 1.3258 14.7557 (27)Heat Loss Floor 1 42.3200 0.1300 5.5016 (28a)External Wall 1 89.6100 13.2500 76.3600 0.1800 13.7448 (29a)External Roof 1 42.3200 42.3200 0.1300 5.5016 (30)Total net area of external elements Aum(A, m2) 174.2500 (31)Fabric heat loss, W/K = Sum (A x U) (26)...(30) + (32) = 41.6237 (33)

    Thermal mass parameter (TMP = Cm / TFA) in kJ/m2K 250.0000 (35)Thermal bridges (Sum(L x Psi) calculated using Appendix K) 9.3330 (36)Total fabric heat loss (33) + (36) = 50.9567 (37)

    Ventilation heat loss calculated monthly (38)m = 0.33 x (25)m x (5) Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec (38)m 40.2557 40.0131 39.7752 38.6579 38.4489 37.4758 37.4758 37.2956 37.8506 38.4489 38.8718 39.3139 (38)Heat transfer coeff 91.2124 90.9697 90.7319 89.6146 89.4056 88.4325 88.4325 88.2523 88.8073 89.4056 89.8284 90.2705 (39)Average = Sum(39)m / 12 = 89.6136 (39)

    Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec HLP 1.0777 1.0748 1.0720 1.0588 1.0563 1.0448 1.0448 1.0427 1.0492 1.0563 1.0613 1.0665 (40)HLP (average) 1.0588 (40)Days in month 31 28 31 30 31 30 31 31 30 31 30 31 (41)

    ----------------------------------------------------------------------------------------------------4. Water heating energy requirements (kWh/year)----------------------------------------------------------------------------------------------------Assumed occupancy 2.5450 (42)Average daily hot water use (litres/day) 94.6445 (43)

    Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Daily hot water use 104.1089 100.3232 96.5374 92.7516 88.9658 85.1800 85.1800 88.9658 92.7516 96.5374 100.3232 104.1089 (44)Energy conte 154.3906 135.0310 139.3399 121.4799 116.5628 100.5849 93.2067 106.9560 108.2334 126.1356 137.6869 149.5190 (45)Energy content (annual) Total = Sum(45)m = 1489.1265 (45)Distribution loss (46)m = 0.15 x (45)m 23.1586 20.2546 20.9010 18.2220 17.4844 15.0877 13.9810 16.0434 16.2350 18.9203 20.6530 22.4279 (46)Water storage loss:Total storage loss 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 (56)If cylinder contains dedicated solar storage

    FULL SAP CALCULATION PRINTOUT Calcula on Type: New Build (As Designed)

    Page 10 of 41

    Regs Region: EnglandElmhurst Energy Systems SAP2012 Calculator (Design System) version 4.10r08

  • CALCULATION OF TARGET EMISSIONS 09 Jan 2014

    0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 (57)Combi loss 50.9589 46.0274 49.1944 45.7405 45.3360 42.0066 43.4068 45.3360 45.7405 49.1944 49.3151 50.9589 (61)Total heat required for water heating calculated for each month 205.3495 181.0584 188.5343 167.2204 161.8988 142.5915 136.6135 152.2920 153.9739 175.3300 187.0019 200.4779 (62)Solar input 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 (63) Solar input (sum of months) = Sum(63)m = 0.0000 (63)Output from w/h 205.3495 181.0584 188.5343 167.2204 161.8988 142.5915 136.6135 152.2920 153.9739 175.3300 187.0019 200.4779 (64) Total per year (kWh/year) = Sum(64)m = 2052.3420 (64)Heat gains from water heating, kWh/month 64.0746 56.4046 58.6291 51.8272 50.0911 43.9461 41.8429 46.8969 47.4227 54.2387 58.1096 62.4548 (65)

    ----------------------------------------------------------------------------------------------------5. Internal gains (see Table 5 and 5a)----------------------------------------------------------------------------------------------------Metabolic gains (Table 5), Watts Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec (66)m 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 (66)Lighting gains (calculated in Appendix L, equation L9 or L9a), also see Table 5 22.1924 19.7111 16.0301 12.1358 9.0717 7.6587 8.2755 10.7568 14.4377 18.3320 21.3962 22.8091 (67)Appliances gains (calculated in Appendix L, equation L13 or L13a), also see Table 5 228.8645 231.2394 225.2547 212.5141 196.4313 181.3158 171.2177 168.8428 174.8274 187.5681 203.6508 218.7664 (68)Cooking gains (calculated in Appendix L, equation L15 or L15a), also see Table 5 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 (69)Pumps, fans 3.0000 3.0000 3.0000 3.0000 3.0000 3.0000 3.0000 3.0000 3.0000 3.0000 3.0000 3.0000 (70)Losses e.g. evaporation (negative values) (Table 5) -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 (71)Water heating gains (Table 5) 86.1218 83.9355 78.8026 71.9822 67.3268 61.0363 56.2405 63.0334 65.8649 72.9015 80.7078 83.9446 (72)Total internal gains 401.3541 399.0614 384.2628 360.8076 337.0052 314.1862 299.9091 306.8084 319.3055 342.9770 369.9303 389.6956 (73)

    ----------------------------------------------------------------------------------------------------6. Solar gains----------------------------------------------------------------------------------------------------

    [Jan] Area Solar flux g FF Access Gains m2 Table 6a Specific data Specific data factor W W/m2 or Table 6b or Table 6c Table 6d ----------------------------------------------------------------------------------------------------Northeast 6.2200 11.2829 0.6300 0.7000 0.7700 21.4479 (75)Southwest 4.9100 36.7938 0.6300 0.7000 0.7700 55.2113 (79)----------------------------------------------------------------------------------------------------

    Solar gains 76.6592 137.7031 207.3344 288.6151 352.2235 362.4107 344.1032 294.7016 235.1753 157.2934 93.1175 64.7648 (83)Total gains 478.0133 536.7645 591.5973 649.4227 689.2287 676.5969 644.0123 601.5101 554.4808 500.2704 463.0478 454.4604 (84)

    ----------------------------------------------------------------------------------------------------7. Mean internal temperature (heating season)----------------------------------------------------------------------------------------------------Temperature during heating periods in the living area from Table 9, Th1 (C) 21.0000 (85)Utilisation factor for gains for living area, ni1,m (see Table 9a) Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec tau 64.4405 64.6125 64.7818 65.5895 65.7429 66.4663 66.4663 66.6020 66.1858 65.7429 65.4334 65.1129alpha 5.2960 5.3075 5.3188 5.3726 5.3829 5.4311 5.4311 5.4401 5.4124 5.3829 5.3622 5.3409util living area 0.9985 0.9969 0.9921 0.9735 0.9107 0.7605 0.5881 0.6468 0.8830 0.9833 0.9969 0.9989 (86)

    MIT 19.8239 19.9543 20.1798 20.4898 20.7700 20.9419 20.9883 20.9809 20.8608 20.5056 20.1124 19.8027 (87)Th 2 20.0191 20.0215 20.0238 20.0346 20.0367 20.0462 20.0462 20.0479 20.0425 20.0367 20.0326 20.0283 (88)util rest of house 0.9980 0.9959 0.9892 0.9628 0.8744 0.6753 0.4689 0.5268 0.8225 0.9747 0.9957 0.9985 (89)MIT 2 18.4435 18.6356 18.9657 19.4190 19.8007 20.0053 20.0416 20.0395 19.9238 19.4479 18.8751 18.4192 (90)Living area fraction fLA = Living area / (4) = 0.2407 (91)MIT 18.7758 18.9530 19.2579 19.6767 20.0340 20.2307 20.2694 20.2661 20.1493 19.7025 19.1729 18.7522 (92)Temperature adjustment 0.0000adjusted MIT 18.7758 18.9530 19.2579 19.6767 20.0340 20.2307 20.2694 20.2661 20.1493 19.7025 19.1729 18.7522 (93)

    ----------------------------------------------------------------------------------------------------8. Space heating requirement ----------------------------------------------------------------------------------------------------

    Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Utilisation 0.9971 0.9942 0.9860 0.9578 0.8743 0.6932 0.4977 0.5557 0.8304 0.9706 0.9940 0.9977 (94)Useful gains 476.6070 533.6397 583.3356 622.0075 602.5584 469.0420 320.5545 334.2533 460.4423 485.5685 460.2690 453.4334 (95)Ext temp. 4.3000 4.9000 6.5000 8.9000 11.7000 14.6000 16.6000 16.4000 14.1000 10.6000 7.1000 4.2000 (96)Heat loss rate W 1320.3688 1278.3977 1157.5455 965.7499 745.1057 497.9344 324.4933 341.1884 537.2216 813.8124 1084.4913 1313.6318 (97)Month fracti 1.0000 1.0000 1.0000 1.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000 1.0000 1.0000 (97a)Space heating kWh 627.7588 500.4774 427.2121 247.4945 106.0552 0.0000 0.0000 0.0000 0.0000 244.2135 449.4401 639.9876 (98)Space heating 3242.6392 (98)Space heating per m2 (98) / (4) = 38.3110 (99)

    ----------------------------------------------------------------------------------------------------8c. Space cooling requirement----------------------------------------------------------------------------------------------------Not applicable

    ----------------------------------------------------------------------------------------------------9a. Energy requirements - Individual heating systems, including micro-CHP

    FULL SAP CALCULATION PRINTOUT Calcula on Type: New Build (As Designed)

    Page 11 of 41

    Regs Region: EnglandElmhurst Energy Systems SAP2012 Calculator (Design System) version 4.10r08

  • CALCULATION OF TARGET EMISSIONS 09 Jan 2014

    ----------------------------------------------------------------------------------------------------Fraction of space heat from secondary/supplementary system (Table 11) 0.0000 (201)Fraction of space heat from main system(s) 1.0000 (202)Efficiency of main space heating system 1 (in %) 93.4000 (206)Efficiency of secondary/supplementary heating system, % 0.0000 (208)Space heating requirement 3471.7765 (211)

    Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Space heating requirement 627.7588 500.4774 427.2121 247.4945 106.0552 0.0000 0.0000 0.0000 0.0000 244.2135 449.4401 639.9876 (98)Space heating efficiency (main heating system 1) 93.4000 93.4000 93.4000 93.4000 93.4000 0.0000 0.0000 0.0000 0.0000 93.4000 93.4000 93.4000 (210)Space heating fuel (main heating system) 672.1186 535.8430 457.4006 264.9834 113.5495 0.0000 0.0000 0.0000 0.0000 261.4706 481.1992 685.2116 (211)Water heating requirement 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 (215)

    Water heatingWater heating requirement 205.3495 181.0584 188.5343 167.2204 161.8988 142.5915 136.6135 152.2920 153.9739 175.3300 187.0019 200.4779 (64)Efficiency of water heater 80.3000 (216)(217)m 87.6816 87.4770 87.0476 86.0366 84.0152 80.3000 80.3000 80.3000 80.3000 85.8855 87.1782 87.7668 (217)Fuel for water heating, kWh/month 234.1989 206.9783 216.5875 194.3597 192.7018 177.5734 170.1289 189.6538 191.7483 204.1438 214.5054 228.4211 (219)Water heating fuel used 2421.0009 (219)Annual totals kWh/yearSpace heating fuel - main system 3471.7765 (211)Space heating fuel - secondary 0.0000 (215)

    Electricity for pumps and fans: central heating pump 30.0000 (230c) main heating flue fan 45.0000 (230e)Total electricity for the above, kWh/year 75.0000 (231)Electricity for lighting (calculated in Appendix L) 391.9239 (232)Total delivered energy for all uses 6359.7012 (238)

    ----------------------------------------------------------------------------------------------------12a. Carbon dioxide emissions - Individual heating systems including micro-CHP---------------------------------------------------------------------------------------------------- Energy Emission factor Emissions kWh/year kg CO2/kWh kg CO2/yearSpace heating - main system 1 3471.7765 0.2160 749.9037 (261)Space heating - secondary 0.0000 0.0000 0.0000 (263)Water heating (other fuel) 2421.0009 0.2160 522.9362 (264)Space and water heating 1272.8399 (265)Pumps and fans 75.0000 0.5190 38.9250 (267)Energy for lighting 391.9239 0.5190 203.4085 (268)Total CO2, kg/m2/year 1515.1734 (272)Emissions per m2 for space and water heating 15.0383 (272a)Fuel factor (mains gas) 1.0000Emissions per m2 for lighting 2.4032 (272b)Emissions per m2 for pumps and fans 0.4599 (272c)Target Carbon Dioxide Emission Rate (TER) = (15.0383 * 1.00) + 2.4032 + 0.4599, rounded to 2 d.p. 17.9000 (273)

    ----------------------------------------------------------------------------------------------------

    FULL SAP CALCULATION PRINTOUT Calcula on Type: New Build (As Designed)

    Page 12 of 41

    Regs Region: EnglandElmhurst Energy Systems SAP2012 Calculator (Design System) version 4.10r08

  • CALCULATION OF FABRIC ENERGY EFFICIENCY 09 Jan 2014

    ----------------------------------------------------------------------------------------------------SAP 2012 WORKSHEET FOR New Build (As Designed) (Version 9.92, January 2014)CALCULATION OF FABRIC ENERGY EFFICIENCY 09 Jan 2014--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

    ----------------------------------------------------------------------------------------------------1. Overall dwelling dimensions---------------------------------------------------------------------------------------------------- Area Storey height Volume (m2) (m) (m3)Ground floor 42.3200 (1b) x 2.3100 (2b) = 97.7592 (1b) - (3b)First floor 42.3200 (1c) x 2.5600 (2c) = 108.3392 (1c) - (3c)Total floor area TFA = (1a)+(1b)+(1c)+(1d)+(1e)...(1n) 84.6400 (4)Dwelling volume (3a)+(3b)+(3c)+(3d)+(3e)...(3n) = 206.0984 (5)

    ----------------------------------------------------------------------------------------------------2. Ventilation rate---------------------------------------------------------------------------------------------------- main secondary other total m3 per hour heating heating Number of chimneys 0 + 0 + 0 = 0 * 40 = 0.0000 (6a)Number of open flues 0 + 0 + 0 = 0 * 20 = 0.0000 (6b)Number of intermittent fans 3 * 10 = 30.0000 (7a)Number of passive vents 0 * 10 = 0.0000 (7b)Number of flueless gas fires 0 * 40 = 0.0000 (7c)

    Air changes per hourInfiltration due to chimneys, flues and fans = (6a)+(6b)+(7a)+(7b)+(7c) = 30.0000 / (5) = 0.1456 (8)Pressure test YesMeasured/design AP50 5.0000Infiltration rate 0.3956 (18)Number of sides sheltered 2 (19)

    Shelter factor (20) = 1 - [0.075 x (19)] = 0.8500 (20)Infiltration rate adjusted to include shelter factor (21) = (18) x (20) = 0.3362 (21)

    Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Wind speed 5.1000 5.0000 4.9000 4.4000 4.3000 3.8000 3.8000 3.7000 4.0000 4.3000 4.5000 4.7000 (22)Wind factor 1.2750 1.2500 1.2250 1.1000 1.0750 0.9500 0.9500 0.9250 1.0000 1.0750 1.1250 1.1750 (22a)Adj infilt rate 0.4287 0.4203 0.4119 0.3699 0.3614 0.3194 0.3194 0.3110 0.3362 0.3614 0.3783 0.3951 (22b)Effective ac 0.5919 0.5883 0.5848 0.5684 0.5653 0.5510 0.5510 0.5484 0.5565 0.5653 0.5715 0.5780 (25)

    ----------------------------------------------------------------------------------------------------3. Heat losses and heat loss parameter----------------------------------------------------------------------------------------------------Element Gross Openings NetArea U-value A x U K-value A x K m2 m2 m2 W/m2K W/K kJ/m2K kJ/KFrench Door (Uw = 1.41) 2.1200 1.3347 2.8296 (27)Window (Uw = 1.41) 9.0100 1.3347 12.0258 (27)Solid door tall window 2.1200 1.2000 2.5440 (26)Heat Loss Floor 1 42.3200 0.1500 6.3480 110.0000 4655.2000 (28a)External Wall 1 89.6100 13.2500 76.3600 0.2700 20.6172 60.0000 4581.6000 (29a)External Roof 1 42.3200 42.3200 0.1000 4.2320 9.0000 380.8800 (30)Total net area of external elements Aum(A, m2) 174.2500 (31)Fabric heat loss, W/K = Sum (A x U) (26)...(30) + (32) = 48.5967 (33)Party Wall 1 44.8000 0.0000 0.0000 110.0000 4928.0000 (32)Internal Wall 1 120.2700 9.0000 1082.4300 (32c)Internal Wall 2 14.7600 62.7000 925.4520 (32c)floor 42.3200 18.0000 761.7600 (32d)Internal Ceiling 1 42.3200 9.0000 380.8800 (32e)

    Heat capacity Cm = Sum(A x k) (28)...(30) + (32) + (32a)...(32e) = 17696.2020 (34)Thermal mass parameter (TMP = Cm / TFA) in kJ/m2K 209.0761 (35)Thermal bridges (Sum(L x Psi) calculated using Appendix K) 8.4273 (36)Total fabric heat loss (33) + (36) = 57.0239 (37)

    Ventilation heat loss calculated monthly (38)m = 0.33 x (25)m x (5) Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec (38)m 40.2557 40.0131 39.7752 38.6579 38.4489 37.4758 37.4758 37.2956 37.8506 38.4489 38.8718 39.3139 (38)Heat transfer coeff 97.2796 97.0370 96.7991 95.6818 95.4728 94.4997 94.4997 94.3195 94.8745 95.4728 95.8957 96.3378 (39)Average = Sum(39)m / 12 = 95.6808 (39)

    Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec HLP 1.1493 1.1465 1.1437 1.1305 1.1280 1.1165 1.1165 1.1144 1.1209 1.1280 1.1330 1.1382 (40)HLP (average) 1.1304 (40)Days in month 31 28 31 30 31 30 31 31 30 31 30 31 (41)

    ----------------------------------------------------------------------------------------------------4. Water heating energy requirements (kWh/year)----------------------------------------------------------------------------------------------------Assumed occupancy 2.5450 (42)Average daily hot water use (litres/day) 94.6445 (43)

    Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Daily hot water use 104.1089 100.3232 96.5374 92.7516 88.9658 85.1800 85.1800 88.9658 92.7516 96.5374 100.3232 104.1089 (44)Energy conte 154.3906 135.0310 139.3399 121.4799 116.5628 100.5849 93.2067 106.9560 108.2334 126.1356 137.6869 149.5190 (45)

    FULL SAP CALCULATION PRINTOUT Calcula on Type: New Build (As Designed)

    Page 13 of 41

    Regs Region: EnglandElmhurst Energy Systems SAP2012 Calculator (Design System) version 4.10r08

  • CALCULATION OF FABRIC ENERGY EFFICIENCY 09 Jan 2014

    Energy content (annual) Total = Sum(45)m = 1489.1265 (45)Distribution loss (46)m = 0.15 x (45)m 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 (46)Water storage loss:Total storage loss 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 (56)If cylinder contains dedicated solar storage 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 (57)Primary loss 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 (59)Heat gains from water heating, kWh/month 32.8080 28.6941 29.6097 25.8145 24.7696 21.3743 19.8064 22.7282 22.9996 26.8038 29.2585 31.7728 (65)

    ----------------------------------------------------------------------------------------------------5. Internal gains (see Table 5 and 5a)----------------------------------------------------------------------------------------------------Metabolic gains (Table 5), Watts Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec (66)m 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 127.2516 (66)Lighting gains (calculated in Appendix L, equation L9 or L9a), also see Table 5 22.1924 19.7111 16.0301 12.1358 9.0717 7.6587 8.2755 10.7568 14.4377 18.3320 21.3962 22.8091 (67)Appliances gains (calculated in Appendix L, equation L13 or L13a), also see Table 5 228.8645 231.2394 225.2547 212.5141 196.4313 181.3158 171.2177 168.8428 174.8274 187.5681 203.6508 218.7664 (68)Cooking gains (calculated in Appendix L, equation L15 or L15a), also see Table 5 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 35.7252 (69)Pumps, fans 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 (70)Losses e.g. evaporation (negative values) (Table 5) -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 -101.8013 (71)Water heating gains (Table 5) 44.0968 42.6995 39.7980 35.8534 33.2925 29.6865 26.6215 30.5486 31.9439 36.0266 40.6367 42.7054 (72)Total internal gains 356.3291 354.8254 342.2583 321.6788 299.9709 279.8364 267.2901 271.3236 282.3845 303.1022 326.8592 345.4563 (73)

    ----------------------------------------------------------------------------------------------------6. Solar gains----------------------------------------------------------------------------------------------------

    [Jan] Area Solar flux g FF Access Gains m2 Table 6a Specific data Specific data factor W W/m2 or Table 6b or Table 6c Table 6d ----------------------------------------------------------------------------------------------------Northeast 2.1200 11.2829 0.7100 0.7000 0.7700 8.2385 (75)Northeast 4.1000 11.2829 0.7100 0.7000 0.7700 15.9329 (75)Southwest 4.9100 36.7938 0.7100 0.7000 0.7700 62.2223 (79)----------------------------------------------------------------------------------------------------

    Solar gains 86.3937 155.1893 233.6626 325.2647 396.9503 408.4312 387.7988 332.1241 265.0388 177.2672 104.9419 72.9889 (83)Total gains 442.7228 510.0147 575.9209 646.9435 696.9212 688.2676 655.0889 603.4477 547.4233 480.3694 431.8011 418.4453 (84)

    ----------------------------------------------------------------------------------------------------7. Mean internal temperature (heating season)----------------------------------------------------------------------------------------------------Temperature during heating periods in the living area from Table 9, Th1 (C) 21.0000 (85)Utilisation factor for gains for living area, ni1,m (see Table 9a) Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec tau 50.5307 50.6571 50.7816 51.3746 51.4870 52.0172 52.0172 52.1166 51.8117 51.4870 51.2600 51.0248alpha 4.3687 4.3771 4.3854 4.4250 4.4325 4.4678 4.4678 4.4744 4.4541 4.4325 4.4173 4.4017util living area 0.9975 0.9950 0.9880 0.9649 0.8995 0.7607 0.6015 0.6637 0.8815 0.9789 0.9953 0.9981 (86)

    MIT 19.4921 19.6546 19.9349 20.3172 20.6658 20.8958 20.9721 20.9572 20.7793 20.3308 19.8448 19.4657 (87)Th 2 19.9607 19.9631 19.9653 19.9760 19.9780 19.9874 19.9874 19.9891 19.9838 19.9780 19.9740 19.9698 (88)util rest of house 0.9968 0.9935 0.9843 0.9529 0.8633 0.6777 0.4782 0.5416 0.8245 0.9696 0.9937 0.9975 (89)MIT 2 18.5813 18.7450 19.0253 19.4087 19.7364 19.9326 19.9786 19.9741 19.8468 19.4280 18.9437 18.5620 (90)Living area fraction fLA = Living area / (4) = 0.2407 (91)MIT 18.8005 18.9639 19.2442 19.6274 19.9601 20.1644 20.2177 20.2107 20.0712 19.6453 19.1606 18.7795 (92)Temperature adjustment 0.0000adjusted MIT 18.8005 18.9639 19.2442 19.6274 19.9601 20.1644 20.2177 20.2107 20.0712 19.6453 19.1606 18.7795 (93)

    ----------------------------------------------------------------------------------------------------8. Space heating requirement ----------------------------------------------------------------------------------------------------

    Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Utilisation 0.9956 0.9915 0.9808 0.9478 0.8625 0.6937 0.5078 0.5704 0.8304 0.9656 0.9919 0.9966 (94)Useful gains 440.7964 505.6946 564.8635 613.1563 601.1219 477.4560 332.6677 344.2280 454.5628 463.8508 428.2993 417.0203 (95)Ext temp. 4.3000 4.9000 6.5000 8.9000 11.7000 14.6000 16.6000 16.4000 14.1000 10.6000 7.1000 4.2000 (96)Heat loss rate W 1410.6030 1364.7199 1233.6300 1026.4143 788.6158 525.8366 341.8750 359.4246 566.5150 863.5778 1156.5567 1404.5547 (97)Month fracti 1.0000 1.0000 1.0000 1.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000 1.0000 1.0000 (97a)Space heating kWh 721.5361 577.2650 497.5623 297.5457 139.4955 0.0000 0.0000 0.0000 0.0000 297.3968 524.3454 734.7256 (98)Space heating 3789.8725 (98)Space heating per m2 (98) / (4) = 44.7764 (99)

    ----------------------------------------------------------------------------------------------------8c. Space cooling requirement----------------------------------------------------------------------------------------------------Calculated for June, July and August. See Table 10b Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Ext. temp. 4.3000 4.9000 6.5000 8.9000 11.7000 14.6000 16.6000 16.4000 14.1000 10.6000 7.1000 4.2000Heat loss rate W 0.0000 0.0000 0.0000 0.0000 0.0000 888.2971 699.2977 716.8281 0.0000 0.0000 0.0000 0.0000 (100)

    FULL SAP CALCULATION PRINTOUT Calcula on Type: New Build (As Designed)

    Page 14 of 41

    Regs Region: EnglandElmhurst Energy Systems SAP2012 Calculator (Design System) version 4.10r08

  • CALCULATION OF FABRIC ENERGY EFFICIENCY 09 Jan 2014

    Utilisation 0.0000 0.0000 0.0000 0.0000 0.0000 0.8227 0.8905 0.8598 0.0000 0.0000 0.0000 0.0000 (101)Useful loss 0.0000 0.0000 0.0000 0.0000 0.0000 730.7726 622.6957 616.3027 0.0000 0.0000 0.0000 0.0000 (102)Total gains 0.0000 0.0000 0.0000 0.0000 0.0000 900.5567 859.8461 801.3575 0.0000 0.0000 0.0000 0.0000 (103)Month fracti 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000 1.0000 1.0000 0.0000 0.0000 0.0000 0.0000 (103a)Space cooling kWh 0.0000 0.0000 0.0000 0.0000 0.0000 122.2446 176.4400 137.6807 0.0000 0.0000 0.0000 0.0000 (104)Space cooling 436.3652 (104)Cooled fraction fC = cooled area / (4) = 1.0000 (105)Intermittency factor (Table 10b) 0.0000 0.0000 0.0000 0.0000 0.0000 0.2500 0.2500 0.2500 0.0000 0.0000 0.0000 0.0000 (106)Space cooling kWh 0.0000 0.0000 0.0000 0.0000 0.0000 30.5611 44.1100 34.4202 0.0000 0.0000 0.0000 0.0000 (107)Space cooling 109.0913 (107)Space cooling per m2 1.2889 (108)Energy for space heating 44.7764 (99)Energy for space cooling 1.2889 (108)Total 46.0653 (109)Dwelling Fabric Energy Efficiency (DFEE) 46.1 (109)

    ----------------------------------------------------------------------------------------------------

    FULL SAP CALCULATION PRINTOUT Calcula on Type: New Build (As Designed)

    Page 15 of 41

    Regs Region: EnglandElmhurst Energy Systems SAP2012 Calculator (Design System) version 4.10r08

  • CALCULATION OF TARGET FABRIC ENERGY EFFICIENCY 09 Jan 2014

    ----------------------------------------------------------------------------------------------------SAP 2012 WORKSHEET FOR New Build (As Designed) (Version 9.92, January 2014)CALCULATION OF TARGET FABRIC ENERGY EFFICIENCY 09 Jan 2014--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

    ----------------------------------------------------------------------------------------------------1. Overall dwelling dimensions---------------------------------------------------------------------------------------------------- Area Storey height Volume (m2) (m) (m3)Ground floor 42.3200 (1b) x 2.3100 (2b) = 97.7592 (1b) - (3b)First floor 42.3200 (1c) x 2.5600 (2c) = 108.3392 (1c) - (3c)Total floor area TFA = (1a)+(1b)+(1c)+(1d)+(1e)...(1n) 84.6400 (4)Dwelling volume (3a)+(3b)+(3c)+(3d)+(3e)...(3n) = 206.0984 (5)

    ----------------------------------------------------------------------------------------------------2. Ventilation rate---------------------------------------------------------------------------------------------------- main secondary other total m3 per hour heating