SS-DX16SA www.daikincomfort.com 12/19 Supersedes 11/19 DX16SA High-Efficiency Split System Air Conditioner * Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 6-Year Unit Replacement Limited Warranty and 12-Year Parts Limited Warranty, online registraon must be completed within 60 days of installaon. Addional requirements for annual maintenance are required for the Unit Replacement Limited Warranty. Online registraon and some of the addional requirements are not required in California or Québec. Standard Features High-efficiency Copeland® scroll compressor • High-density foam compressor sound blanket Advanced Copeland® CoreSense™ Technology • Single-speed PSC condenser fan motor Factory-installed filter drier Copper tube / enhanced aluminum fin coil Sweat connecon service valves with easy access to gauge ports AHRI Cerfied; ETL Listed Cabinet Features • Heavy-gauge galvanized steel cabinet with grille-style sound control top Custom Nickel Gray powder-paint finish • 500-hour salt-spray tested • Wire fan discharge grille • Steel louver coil guard • Rust-resistant coated screws • Top and side maintenance access Single-panel access to controls with space pro- vided for field-installed accessories When properly anchored, meets the 2017 Florida Building Code unit integrity requirements for hurri- cane-type winds (Anchor bracket kits available.) Proper sizing and installaon of equipment is crical to achieve opmal performance. Split system air condioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR® criteria. Ask your contractor for details or visit www.energystar.gov. Up to 16 SEER 1½ to 5 TONS Contents Nomenclature........................................ 2 Product Specificaons ........................... 3 Expanded Cooling Data ......................... 4 AHRI Rangs (see note)....................... 24 Dimensions .......................................... 25 Wiring Diagrams ................................. 26 Accessories .......................................... 28

Upload: others

Post on 25-Oct-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

SS-DX16SA www.daikincomfort.com 12/19Supersedes 11/19

DX16SA

High-EfficiencySplit System Air Conditioner

* Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 6-Year Unit Replacement Limited Warranty and 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Additional requirements for annual maintenance are required for the Unit Replacement Limited Warranty. Online registration and some of the additional requirements are not required in California or Québec.

■ Standard Features• High-efficiency Copeland® scroll compressor • High-density foam compressor

sound blanket• Advanced Copeland®

CoreSense™ Technology• Single-speed PSC condenser fan motor• Factory-installed filter drier• Copper tube / enhanced aluminum fin coil• Sweat connection service valves

with easy access to gauge ports• AHRI Certified; ETL Listed

■ Cabinet Features• Heavy-gauge galvanized steel cabinet

with grille-style sound control top • Custom Nickel Gray powder-paint finish • 500-hour salt-spray tested• Wire fan discharge grille• Steel louver coil guard• Rust-resistant coated screws• Top and side maintenance access• Single-panel access to controls with space pro-

vided for field-installed accessories• When properly anchored, meets the 2017 Florida

Building Code unit integrity requirements for hurri-cane-type winds (Anchor bracket kits available.)

Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR® criteria. Ask your contractor for details or visit www.energystar.gov.

Up to 16 SEER 1½ to 5 TONS

ContentsNomenclature ........................................ 2Product Specifications ........................... 3Expanded Cooling Data ......................... 4AHRI Ratings (see note) ....................... 24Dimensions .......................................... 25Wiring Diagrams ................................. 26Accessories .......................................... 28

2 www.daikincomfort.com SS-DX16SA

Nomenclature

D X 16 S A 036 3 AA

1 2 3,4 5 6 7,8,9 10 11,12

Brand Engineering*

D - Daikin Major & Minor revisions* Not used for inventory control.

Type Voltage

X - AC R-410A 1 - 208/230 V Single-Phase 60 Hz

Z - HP R-410A

Nominal Tonnage

SEER 018 - 1½ tons 031 - 2½ tons 048 - 4 tons

14 - 14 SEER 18 - 18 SEER 024 - 2 tons 036 - 3 tons 060 - 5 tons

16 - 16 SEER 20 - 20 SEER 030 - 2½ tons 037 - 3 tons 061 - 5 tons

042 - 3½ tons (high capacity)

Compressor Feature Set

S - Single Stage A - Base D - Deluxe

T - Two Stage C - Communicating N - Nominal

SS-DX16SA www.daikincomfort.com 3

DX16SA0181A*

DX16SA0241A*

DX16SA0301A*

DX16SA 0311A*

DX16SA0361A*

DX16SA 0371A*

DX16SA0421A*

DX16SA0481A*

DX16SA0601A*

DX16SA0611A*

Capacities

Nominal Cooling (BTU/h) 18,000 23,600 29,000 30,000 34,800 36,000 42,000 45,500 54,000 57,000

Decibels 71.5 71.5 71.5 71.5 71.5 73 73 73 73 73

Compressor

RLA 9.0 13.5 12.8 12.8 14.1 15.4 17.9 17.9 21.4 25

LRA 46 58.3 64 64 77 83.9 112 112 135 134

Condenser Fan Motor

Horsepower 1/6 1/6 1/6 1/6 1/6 1/6 1/6 1/4 1/3 1/4

FLA 0.95 0.95 0.95 0.95 0.95 0.95 0.95 1.30 2.80 1.30

Refrigeration System

Refrigerant Line Size

Liquid Line Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"

Suction Line Size (“O.D.) ¾" ¾" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞"

Refrigerant Connection Size

Liquid Valve Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"

Suction Valve Size (“O.D.) ¾" ¾" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞"

Valve Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat

Refrigerant Charge (oz.) 78 70 78 94 94 93 110 121 237 125

Electrical Data

Voltage / Phase (60 Hz) 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1

Minimum Circuit Ampacity ² 12.2 17.8 17.0 17.0 18.6 20.2 23.3 23.7 28.3 32.6

Max. Overcurrent Protection ³ 20 30 25 25 30 35 40 40 50 50

Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253

Electrical Conduit Size ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾"

Equipment Weight (lbs) 145 142 149 161 162 182 206 219 279 291

Ship Weight (lbs) 163 160 167 179 180 204 228 241 301 314

ENERGY STAR® Certified ^ NO

^ Energy Star Notes• Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must

be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. • The www.energystar.gov website provides up-to-date system combinations certified to meet ENERGY STAR requirements.

See Page 24 for all ENERGY STAR certified combinations as of this document’s revision date.

¹ Tested and rated in accordance with AHRI Standard 210/240² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.

Notes• Always check the S&R plate for electrical data on the unit being installed.• Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.• Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.• Installation of these units requires the specified TXV Kit to be installed on the indoor coil.

THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL.

Product Specifications

4 www.daikincomfort.com SS-DX16SA

Expanded Cooling Data — DX16SA0181A* / CA*F3636*6D*+EEP+TXV

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

70

525

MBh

15.8

16.4

17.9

-15

.416

.017

.5-

15.1

15.6

17.1

-14

.715

.216

.7-

14.0

14.5

15.9

-12

.913

.414

.7-

S/T

0.66

0.55

0.38

-0.

690.

570.

40-

0.70

0.59

0.41

-0.

730.

610.

42-

0.75

0.63

0.44

-0.

760.

640.

44-

∆T18

1612

-19

1612

-19

1612

-19

1612

-18

1612

-17

1511

-kW

1.18

1.20

1.23

-1.

261.

281.

31-

1.32

1.35

1.38

-1.

381.

411.

45-

1.43

1.46

1.50

-1.

471.

501.

54-

Amps

4.3

4.3

4.5

-4.

64.

74.

8-

4.9

5.0

5.2

-5.

25.

45.

5-

5.6

5.7

5.9

-5.

96.

06.

2-

Hi P

R19

821

322

5-

222

239

252

-25

327

228

7-

288

310

327

-32

434

836

8-

358

385

406

-Lo

PR

102

109

119

-10

811

512

5-

112

119

130

-11

812

513

7-

124

131

144

-12

813

614

8-

650

MBh

17.1

17.7

19.4

-16

.717

.319

.0-

16.3

16.9

18.5

-15

.916

.518

.1-

15.1

15.7

17.2

-14

.014

.515

.9-

S/T

0.69

0.57

0.40

-0.

710.

590.

41-

0.73

0.61

0.42

-0.

750.

630.

44-

0.78

0.65

0.45

-0.

790.

660.

46-

∆T17

1411

-17

1511

-17

1511

-17

1511

-17

1411

-16

1410

-kW

1.21

1.23

1.26

-1.

281.

311.

34-

1.35

1.38

1.41

-1.

411.

441.

48-

1.46

1.49

1.53

-1.

511.

541.

58-

Amps

4.4

4.5

4.6

-4.

74.

84.

9-

5.1

5.2

5.3

-5.

45.

55.

7-

5.7

5.8

6.0

-6.

06.

26.

4-

Hi P

R20

422

023

2-

229

246

260

-26

028

029

6-

297

319

337

-33

435

937

9-

369

397

419

-Lo

PR

105

112

122

-11

111

812

9-

116

123

134

-12

212

914

1-

127

136

148

-13

214

015

3-

675

MBh

17.1

17.7

19.4

-16

.717

.319

.0-

16.3

16.9

18.5

-15

.916

.518

.1-

15.1

15.7

17.2

-14

.014

.515

.9-

S/T

0.69

0.57

0.40

-0.

710.

590.

41-

0.73

0.61

0.42

-0.

750.

630.

44-

0.78

0.65

0.45

-0.

790.

660.

46-

∆T16

1411

-16

1411

-16

1411

-16

1411

-16

1411

-15

1310

-kW

1.21

1.23

1.26

-1.

281.

311.

34-

1.35

1.38

1.41

-1.

411.

441.

48-

1.46

1.49

1.53

-1.

511.

541.

58-

Amps

4.4

4.5

4.6

-4.

74.

84.

9-

5.1

5.2

5.3

-5.

45.

55.

7-

5.7

5.8

6.0

-6.

06.

26.

4-

Hi P

R20

422

023

2-

229

246

260

-26

028

029

6-

297

319

337

-33

435

937

9-

369

397

419

-Lo

PR

105

112

122

-11

111

812

9-

116

123

134

-12

212

914

1-

127

136

148

-13

214

015

3-

75

525

MBh

16.1

16.5

17.9

19.2

15.7

16.2

17.5

18.8

15.3

15.8

17.1

18.3

15.0

15.4

16.7

17.9

14.2

14.6

15.8

17.0

13.2

13.5

14.7

15.7

S/T

0.75

0.67

0.51

0.33

0.78

0.70

0.53

0.34

0.80

0.72

0.54

0.35

0.83

0.74

0.56

0.36

0.86

0.77

0.58

0.37

0.86

0.77

0.59

0.38

∆T21

2016

1121

2016

1121

2016

1122

2016

1121

2016

1120

1815

10kW

1.19

1.21

1.24

1.28

1.27

1.29

1.32

1.36

1.33

1.36

1.39

1.43

1.39

1.42

1.46

1.50

1.44

1.47

1.51

1.55

1.48

1.51

1.56

1.60

Amps

4.3

4.4

4.5

4.7

4.6

4.7

4.9

5.0

5.0

5.1

5.2

5.4

5.3

5.4

5.6

5.8

5.6

5.7

5.9

6.1

5.9

6.1

6.3

6.5

Hi P

R20

021

522

723

722

424

225

526

625

527

529

030

329

131

333

034

532

735

237

238

836

138

941

142

8Lo

PR

103

110

120

128

109

116

127

135

113

121

132

140

119

127

138

147

125

133

145

154

129

137

150

160

650

MBh

17.4

17.9

19.4

20.8

17.0

17.5

19.0

20.3

16.6

17.1

18.5

19.9

16.2

16.7

18.1

19.4

15.4

15.8

17.2

18.4

14.3

14.7

15.9

17.1

S/T

0.78

0.70

0.53

0.34

0.81

0.72

0.55

0.35

0.83

0.74

0.56

0.36

0.86

0.77

0.58

0.37

0.89

0.80

0.60

0.39

0.90

0.80

0.61

0.39

∆T19

1815

1019

1815

1019

1815

1020

1815

1019

1815

1018

1714

9kW

1.21

1.24

1.27

1.30

1.29

1.32

1.35

1.39

1.36

1.39

1.42

1.46

1.42

1.45

1.49

1.53

1.47

1.50

1.54

1.59

1.52

1.55

1.59

1.64

Amps

4.4

4.5

4.6

4.8

4.7

4.8

5.0

5.2

5.1

5.2

5.4

5.6

5.4

5.6

5.7

5.9

5.8

5.9

6.1

6.3

6.1

6.2

6.4

6.7

Hi P

R20

622

223

424

423

124

926

327

426

328

329

931

230

032

334

135

533

736

338

340

037

340

142

344

2Lo

PR

106

113

124

132

113

120

131

139

117

124

136

145

123

131

143

152

129

137

150

159

133

142

155

165

675

MBh

17.4

17.9

19.4

20.8

17.0

17.5

19.0

20.3

16.6

17.1

18.5

19.9

16.2

16.7

18.1

19.4

15.4

15.8

17.2

18.4

14.3

14.7

15.9

17.1

S/T

0.78

0.70

0.53

0.34

0.81

0.72

0.55

0.35

0.83

0.74

0.56

0.36

0.86

0.77

0.58

0.37

0.89

0.80

0.60

0.39

0.90

0.80

0.61

0.39

∆T19

1714

1019

1714

1019

1714

1019

1714

1019

1714

1017

1613

9kW

1.21

1.24

1.27

1.30

1.29

1.32

1.35

1.39

1.36

1.39

1.42

1.46

1.42

1.45

1.49

1.53

1.47

1.50

1.54

1.59

1.52

1.55

1.59

1.64

Amps

4.4

4.5

4.6

4.8

4.7

4.8

5.0

5.2

5.1

5.2

5.4

5.6

5.4

5.6

5.7

5.9

5.8

5.9

6.1

6.3

6.1

6.2

6.4

6.7

Hi P

R20

622

223

424

423

124

926

327

426

328

329

931

230

032

334

135

533

736

338

340

037

340

142

344

2Lo

PR

106

113

124

132

113

120

131

139

117

124

136

145

123

131

143

152

129

137

150

159

133

142

155

165

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

SS-DX16SA www.daikincomfort.com 5

Expanded Cooling Data — DX16SA0181A* / CA*F3636*6D*+EEP+TXV (cont.)

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

80

525

MBh

16.4

16.7

17.9

19.1

16.0

16.3

17.4

18.6

15.6

15.9

17.0

18.2

15.2

15.6

16.6

17.8

14.5

14.8

15.8

16.9

13.4

13.7

14.6

15.6

S/T

0.83

0.77

0.63

0.47

0.86

0.80

0.65

0.49

0.88

0.82

0.67

0.50

0.91

0.85

0.69

0.52

0.94

0.88

0.72

0.54

0.95

0.89

0.72

0.54

∆T24

2320

1624

2320

1624

2320

1624

2320

1624

2320

1622

2119

15kW

1.20

1.22

1.25

1.28

1.27

1.30

1.33

1.37

1.34

1.37

1.40

1.44

1.40

1.43

1.47

1.51

1.45

1.48

1.52

1.57

1.49

1.52

1.57

1.61

Amps

4.3

4.4

4.6

4.7

4.6

4.7

4.9

5.1

5.0

5.1

5.3

5.5

5.3

5.5

5.6

5.8

5.7

5.8

6.0

6.2

6.0

6.1

6.3

6.5

Hi P

R20

221

723

023

922

724

425

826

925

827

729

330

629

431

633

434

833

035

537

539

236

539

341

543

3Lo

PR

104

111

121

129

110

117

128

136

115

122

133

142

120

128

140

149

126

134

146

156

130

139

152

161

650

MBh

17.7

18.1

19.4

20.7

17.3

17.7

18.9

20.2

16.9

17.3

18.5

19.7

16.5

16.8

18.0

19.2

15.7

16.0

17.1

18.3

14.5

14.8

15.8

16.9

S/T

0.86

0.80

0.65

0.49

0.89

0.83

0.68

0.51

0.91

0.85

0.69

0.52

0.94

0.88

0.72

0.54

0.97

0.91

0.74

0.56

0.98

0.92

0.75

0.56

∆T21

2118

1422

2118

1422

2118

1422

2118

1522

2118

1420

1917

13kW

1.22

1.24

1.28

1.31

1.30

1.32

1.36

1.40

1.37

1.40

1.43

1.48

1.43

1.46

1.50

1.54

1.48

1.51

1.56

1.60

1.53

1.56

1.60

1.65

Amps

4.4

4.5

4.7

4.8

4.8

4.9

5.0

5.2

5.1

5.3

5.4

5.6

5.5

5.6

5.8

6.0

5.8

5.9

6.1

6.4

6.1

6.3

6.5

6.7

Hi P

R20

822

423

724

723

425

126

627

726

628

630

231

530

332

634

435

934

136

638

740

437

640

542

844

6Lo

PR

108

114

125

133

114

121

132

141

118

126

137

146

124

132

144

153

130

138

151

161

134

143

156

166

675

MBh

17.7

18.1

19.4

20.7

17.3

17.7

18.9

20.2

16.9

17.3

18.5

19.7

16.5

16.8

18.0

19.2

15.7

16.0

17.1

18.3

14.5

14.8

15.8

16.9

S/T

0.86

0.80

0.65

0.49

0.89

0.83

0.68

0.51

0.91

0.85

0.69

0.52

0.94

0.88

0.72

0.54

0.97

0.91

0.74

0.56

0.98

0.92

0.75

0.56

∆T21

2017

1421

2017

1421

2017

1421

2018

1421

2017

1419

1916

13kW

1.22

1.24

1.28

1.31

1.30

1.32

1.36

1.40

1.37

1.40

1.43

1.48

1.43

1.46

1.50

1.54

1.48

1.51

1.56

1.60

1.53

1.56

1.60

1.65

Amps

4.4

4.5

4.7

4.8

4.8

4.9

5.0

5.2

5.1

5.3

5.4

5.6

5.5

5.6

5.8

6.0

5.8

5.9

6.1

6.4

6.1

6.3

6.5

6.7

Hi P

R20

822

423

724

723

425

126

627

726

628

630

231

530

332

634

435

934

136

638

740

437

640

542

844

6Lo

PR

108

114

125

133

114

121

132

141

118

126

137

146

124

132

144

153

130

138

151

161

134

143

156

166

85

525

MBh

16.6

17.0

17.8

19.0

16.3

16.6

17.4

18.5

15.9

16.2

16.9

18.1

15.5

15.8

16.5

17.6

14.7

15.0

15.7

16.8

13.6

13.9

14.5

15.5

S/T

0.87

0.84

0.75

0.61

0.90

0.87

0.78

0.63

0.92

0.89

0.80

0.65

0.95

0.92

0.83

0.67

0.99

0.95

0.86

0.70

0.99

0.96

0.87

0.70

∆T25

2523

2026

2524

2126

2524

2126

2524

2125

2524

2024

2322

19kW

1.21

1.23

1.26

1.29

1.28

1.31

1.34

1.38

1.35

1.38

1.41

1.45

1.41

1.44

1.48

1.52

1.46

1.49

1.53

1.58

1.51

1.53

1.58

1.63

Amps

4.4

4.5

4.6

4.7

4.7

4.8

4.9

5.1

5.1

5.2

5.3

5.5

5.4

5.5

5.7

5.9

5.7

5.8

6.0

6.2

6.0

6.2

6.4

6.6

Hi P

R20

422

023

224

222

924

626

027

126

028

029

630

929

731

933

735

233

435

937

939

536

939

741

943

7Lo

PR

105

112

122

130

111

118

129

138

116

123

134

143

122

129

141

150

127

136

148

158

132

140

153

163

650

MBh

18.0

18.4

19.3

20.5

17.6

18.0

18.8

20.1

17.2

17.5

18.4

19.6

16.8

17.1

17.9

19.1

15.9

16.2

17.0

18.2

14.8

15.0

15.8

16.8

S/T

0.90

0.87

0.78

0.63

0.93

0.90

0.81

0.66

0.95

0.92

0.83

0.67

0.98

0.95

0.86

0.70

1.00

0.99

0.89

0.72

1.00

0.99

0.90

0.73

∆T23

2321

1823

2322

1923

2322

1923

2322

1923

2321

1921

2120

17kW

1.23

1.25

1.29

1.32

1.31

1.33

1.37

1.41

1.38

1.41

1.44

1.49

1.44

1.47

1.51

1.55

1.49

1.52

1.57

1.61

1.54

1.57

1.62

1.66

Amps

4.5

4.6

4.7

4.9

4.8

4.9

5.1

5.2

5.2

5.3

5.5

5.7

5.5

5.7

5.8

6.0

5.9

6.0

6.2

6.4

6.2

6.3

6.5

6.8

Hi P

R21

022

623

924

923

625

426

828

026

828

930

531

830

632

934

736

234

437

039

140

838

040

943

245

0Lo

PR

109

116

126

134

115

122

133

142

119

127

139

148

125

133

146

155

131

140

153

162

136

145

158

168

675

MBh

18.0

18.4

19.3

20.5

17.6

18.0

18.8

20.1

17.2

17.5

18.4

19.6

16.8

17.1

17.9

19.1

15.9

16.2

17.0

18.2

14.8

15.0

15.8

16.8

S/T

0.90

0.87

0.78

0.63

0.93

0.90

0.81

0.66

0.95

0.92

0.83

0.67

0.98

0.95

0.86

0.70

1.00

0.99

0.89

0.72

1.00

0.99

0.90

0.73

∆T22

2220

1822

2221

1822

2221

1823

2221

1822

2221

1820

2019

17kW

1.23

1.25

1.29

1.32

1.31

1.33

1.37

1.41

1.38

1.41

1.44

1.49

1.44

1.47

1.51

1.55

1.49

1.52

1.57

1.61

1.54

1.57

1.62

1.66

Amps

4.5

4.6

4.7

4.9

4.8

4.9

5.1

5.2

5.2

5.3

5.5

5.7

5.5

5.7

5.8

6.0

5.9

6.0

6.2

6.4

6.2

6.3

6.5

6.8

Hi P

R21

022

623

924

923

625

426

828

026

828

930

531

830

632

934

736

234

437

039

140

838

040

943

245

0Lo

PR

109

116

126

134

115

122

133

142

119

127

139

148

125

133

146

155

131

140

153

162

136

145

158

168

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

6 www.daikincomfort.com SS-DX16SA

Expanded Cooling Data — DX16SA0241A* / CA*F3636*6D*+EEP+TXV

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

70

700

MBh

22.1

22.9

25.1

-21

.622

.424

.5-

21.1

21.9

23.9

-20

.621

.323

.4-

19.5

20.3

22.2

-18

.118

.820

.6-

S/T

0.68

0.57

0.39

-0.

700.

590.

41-

0.72

0.60

0.42

-0.

750.

620.

43-

0.77

0.65

0.45

-0.

780.

650.

45-

∆T20

1713

-20

1713

-20

1713

-20

1713

-20

1713

-19

1612

-kW

1.96

1.96

1.96

-1.

961.

961.

96-

1.96

1.96

1.96

-1.

961.

961.

97-

1.96

1.97

1.97

-1.

971.

971.

97-

Amps

7.6

7.6

7.6

-7.

67.

67.

6-

7.7

7.7

7.7

-7.

77.

77.

7-

7.7

7.7

7.8

-7.

87.

87.

8-

Hi P

R20

522

123

3-

230

248

262

-26

228

229

8-

298

321

339

-33

636

138

1-

371

399

421

-Lo

PR

102

109

119

-10

811

512

6-

112

120

131

-11

812

613

7-

124

132

144

-12

813

614

9-

750

MBh

22.5

23.3

25.5

-21

.922

.724

.9-

21.4

22.2

24.3

-20

.921

.623

.7-

19.8

20.6

22.5

-18

.419

.120

.9-

S/T

0.71

0.59

0.41

-0.

730.

610.

42-

0.75

0.63

0.43

-0.

770.

650.

45-

0.80

0.67

0.46

-0.

810.

680.

47-

∆T19

1713

-20

1713

-20

1713

-20

1713

-20

1713

-18

1612

-kW

1.96

1.96

1.96

-1.

961.

961.

96-

1.96

1.96

1.96

-1.

961.

961.

97-

1.97

1.97

1.97

-1.

971.

971.

97-

Amps

7.6

7.6

7.6

-7.

67.

67.

7-

7.7

7.7

7.7

-7.

77.

77.

7-

7.7

7.8

7.8

-7.

87.

87.

8-

Hi P

R20

922

523

7-

234

252

266

-26

628

730

3-

303

326

345

-34

136

738

8-

377

406

429

-Lo

PR

104

111

121

-11

011

712

8-

114

122

133

-12

012

814

0-

126

134

146

-13

013

915

1-

900

MBh

23.2

24.1

26.4

-22

.723

.525

.8-

22.2

23.0

25.2

-21

.622

.424

.5-

20.5

21.3

23.3

-19

.019

.721

.6-

S/T

0.75

0.63

0.43

-0.

780.

650.

45-

0.80

0.67

0.46

-0.

820.

690.

48-

0.85

0.71

0.49

-0.

860.

720.

50-

∆T18

1512

-18

1612

-18

1612

-18

1612

-18

1512

-17

1411

-kW

1.96

1.96

1.96

-1.

961.

961.

96-

1.96

1.96

1.96

-1.

961.

971.

97-

1.97

1.97

1.97

-1.

971.

971.

97-

Amps

7.6

7.6

7.6

-7.

67.

67.

7-

7.7

7.7

7.7

-7.

77.

77.

7-

7.7

7.8

7.8

-7.

87.

87.

8-

Hi P

R21

322

924

2-

239

257

271

-27

229

230

9-

309

333

352

-34

837

539

6-

385

414

437

-Lo

PR

106

113

123

-11

211

913

0-

117

124

136

-12

313

014

2-

128

137

149

-13

314

115

4-

75

700

MBh

22.5

23.2

25.1

26.9

22.0

22.6

24.5

26.3

21.4

22.1

23.9

25.6

20.9

21.5

23.3

25.0

19.9

20.5

22.1

23.8

18.4

19.0

20.5

22.0

S/T

0.77

0.69

0.52

0.34

0.80

0.72

0.54

0.35

0.82

0.73

0.56

0.36

0.85

0.76

0.57

0.37

0.88

0.79

0.60

0.38

0.89

0.79

0.60

0.39

∆T23

2117

1223

2117

1223

2117

1223

2118

1223

2117

1221

2016

11kW

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

Amps

7.6

7.6

7.6

7.6

7.6

7.6

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.8

7.7

7.7

7.8

7.8

7.8

7.8

7.8

7.8

Hi P

R20

722

323

624

623

325

026

427

626

528

530

131

430

132

434

235

733

936

538

540

237

440

342

644

4Lo

PR

103

110

120

128

109

116

127

135

114

121

132

141

119

127

139

148

125

133

145

155

129

138

150

160

750

MBh

22.8

23.5

25.4

27.3

22.3

23.0

24.9

26.7

21.8

22.4

24.3

26.0

21.2

21.9

23.7

25.4

20.2

20.8

22.5

24.1

18.7

19.2

20.8

22.4

S/T

0.80

0.72

0.54

0.35

0.83

0.74

0.56

0.36

0.85

0.76

0.58

0.37

0.88

0.79

0.60

0.38

0.91

0.82

0.62

0.40

0.92

0.82

0.62

0.40

∆T22

2117

1223

2117

1223

2117

1223

2117

1223

2117

1221

1916

11kW

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.97

1.96

1.96

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

Amps

7.6

7.6

7.6

7.6

7.6

7.6

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.8

7.7

7.8

7.8

7.8

7.8

7.8

7.8

7.8

Hi P

R21

122

724

025

023

725

526

928

026

929

030

631

930

633

034

836

334

537

139

240

938

141

043

345

2Lo

PR

105

112

122

130

111

118

129

138

116

123

134

143

121

129

141

150

127

135

148

157

132

140

153

163

900

MBh

23.6

24.3

26.3

28.3

23.1

23.8

25.7

27.6

22.5

23.2

25.1

27.0

22.0

22.6

24.5

26.3

20.9

21.5

23.3

25.0

19.3

19.9

21.6

23.1

S/T

0.85

0.76

0.58

0.37

0.88

0.79

0.60

0.38

0.91

0.81

0.61

0.39

0.93

0.84

0.63

0.41

0.97

0.87

0.66

0.42

0.98

0.87

0.66

0.43

∆T21

1916

1121

1916

1121

1916

1121

1916

1121

1916

1119

1815

10kW

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.97

1.96

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

Amps

7.6

7.6

7.6

7.6

7.6

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.8

7.8

7.8

7.8

7.8

7.8

7.8

7.8

7.8

7.9

Hi P

R21

523

124

425

524

126

027

428

627

429

531

232

531

333

635

537

135

237

840

041

738

941

844

246

1Lo

PR

107

114

125

133

113

121

132

140

118

125

137

146

124

132

144

153

130

138

151

160

134

143

156

166

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

SS-DX16SA www.daikincomfort.com 7

Expanded Cooling Data — DX16SA0241A* / CA*F3636*6D*+EEP+TXV (cont.)

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

80

700

MBh

22.9

23.4

25.0

26.7

22.4

22.8

24.4

26.1

21.8

22.3

23.8

25.5

21.3

21.8

23.2

24.8

20.2

20.7

22.1

23.6

18.7

19.1

20.5

21.9

S/T

0.85

0.80

0.65

0.48

0.88

0.82

0.67

0.50

0.90

0.84

0.69

0.51

0.93

0.87

0.71

0.53

0.97

0.91

0.74

0.55

0.97

0.91

0.74

0.56

∆T25

2421

1726

2521

1726

2522

1726

2522

1726

2521

1724

2320

16kW

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.97

1.96

1.96

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

Amps

7.6

7.6

7.6

7.6

7.6

7.6

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.8

7.7

7.8

7.8

7.8

7.8

7.8

7.8

7.8

Hi P

R20

922

523

824

823

525

326

727

826

728

830

431

730

432

734

636

134

236

838

940

637

840

743

044

8Lo

PR

104

111

121

129

110

117

128

137

115

122

133

142

121

128

140

149

126

134

147

156

131

139

152

162

750

MBh

23.2

23.7

25.4

27.1

22.7

23.2

24.8

26.5

22.2

22.6

24.2

25.9

21.6

22.1

23.6

25.2

20.5

21.0

22.4

24.0

19.0

19.4

20.8

22.2

S/T

0.88

0.82

0.67

0.50

0.91

0.85

0.70

0.52

0.93

0.88

0.71

0.53

0.96

0.90

0.74

0.55

1.00

0.94

0.76

0.57

1.00

0.95

0.77

0.58

∆T25

2421

1725

2421

1725

2421

1726

2421

1725

2421

1723

2320

16kW

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.97

1.96

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

Amps

7.6

7.6

7.6

7.6

7.6

7.6

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.8

7.7

7.8

7.8

7.8

7.8

7.8

7.8

7.8

Hi P

R21

322

924

225

223

925

727

228

327

229

330

932

231

033

335

236

734

837

539

641

338

541

443

745

6Lo

PR

106

113

123

131

112

119

130

139

117

124

136

144

123

130

142

152

128

137

149

159

133

141

154

164

900

MBh

24.1

24.6

26.3

28.1

23.5

24.0

25.6

27.4

22.9

23.4

25.0

26.8

22.4

22.9

24.4

26.1

21.3

21.7

23.2

24.8

19.7

20.1

21.5

23.0

S/T

0.93

0.88

0.71

0.53

1.00

0.91

0.74

0.55

1.00

0.93

0.76

0.57

1.00

0.96

0.78

0.58

1.00

1.00

0.81

0.61

1.00

1.00

0.82

0.61

∆T23

2219

1524

2219

1523

2219

1523

2220

1622

2219

1520

2118

14kW

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.97

1.97

1.96

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

Amps

7.6

7.6

7.6

7.7

7.6

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.8

7.8

7.8

7.8

7.8

7.8

7.8

7.8

7.8

7.9

Hi P

R21

723

424

725

724

426

227

728

927

729

831

532

931

634

035

937

435

538

240

442

139

342

244

646

5Lo

PR

108

115

126

134

115

122

133

142

119

127

138

147

125

133

145

155

131

139

152

162

136

144

157

168

85

700

MBh

23.3

23.7

24.9

26.5

22.7

23.2

24.3

25.9

22.2

22.6

23.7

25.3

21.7

22.1

23.1

24.7

20.6

21.0

22.0

23.4

19.1

19.4

20.4

21.7

S/T

0.89

0.86

0.77

0.63

0.92

0.89

0.80

0.65

0.94

0.91

0.82

0.67

0.97

0.94

0.85

0.69

1.00

0.98

0.88

0.71

1.00

0.98

0.89

0.72

∆T27

2725

2228

2726

2228

2726

2228

2726

2227

2725

2225

2524

21kW

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.97

1.96

1.96

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

Amps

7.6

7.6

7.6

7.6

7.6

7.6

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.8

7.7

7.8

7.8

7.8

7.8

7.8

7.8

7.8

Hi P

R21

122

824

025

123

725

527

028

127

029

030

732

030

733

134

936

434

637

239

341

038

241

143

445

3Lo

PR

106

112

123

131

112

119

130

138

116

123

135

143

122

130

141

151

128

136

148

158

132

140

153

163

750

MBh

23.6

24.1

25.2

26.9

23.1

23.5

24.7

26.3

22.5

23.0

24.1

25.7

22.0

22.4

23.5

25.1

20.9

21.3

22.3

23.8

19.4

19.7

20.7

22.0

S/T

0.92

0.89

0.80

0.65

0.95

0.92

0.83

0.67

0.98

0.94

0.85

0.69

1.00

0.98

0.88

0.71

1.00

1.00

0.91

0.74

1.00

1.00

0.92

0.75

∆T27

2625

2127

2725

2227

2725

2227

2725

2226

2625

2224

2423

20kW

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.97

1.96

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

Amps

7.6

7.6

7.6

7.6

7.6

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.8

7.8

7.8

7.8

7.8

7.8

7.8

7.8

7.8

7.9

Hi P

R21

523

224

425

524

126

027

428

627

529

531

232

531

333

635

537

135

237

940

041

738

941

844

246

1Lo

PR

107

114

125

133

113

121

132

140

118

125

137

146

124

132

144

153

130

138

151

161

134

143

156

166

900

MBh

24.5

24.9

26.1

27.9

23.9

24.4

25.5

27.2

23.3

23.8

24.9

26.6

22.8

23.2

24.3

25.9

21.6

22.0

23.1

24.6

20.0

20.4

21.4

22.8

S/T

0.98

0.94

0.85

0.69

1.00

0.98

0.88

0.72

1.00

1.00

0.91

0.74

1.00

1.00

0.94

0.76

1.00

1.00

0.97

0.79

1.00

1.00

0.98

0.79

∆T24

2423

2024

2423

2024

2423

2023

2423

2022

2323

2020

2121

19kW

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.96

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

1.97

Amps

7.6

7.6

7.6

7.7

7.6

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.8

7.8

7.8

7.8

7.8

7.8

7.8

7.8

7.8

7.9

Hi P

R21

923

624

926

024

626

528

029

228

030

131

833

231

934

336

237

835

938

640

842

539

642

745

047

0Lo

PR

110

117

127

135

116

123

134

143

120

128

140

149

126

134

147

156

132

141

154

164

137

146

159

169

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

8 www.daikincomfort.com SS-DX16SA

Expanded Cooling Data — DX16SA0301A* / CA*F3743*6D*+EEP+TXV

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

70

875

MBh

25.5

26.4

28.9

-24

.925

.828

.2-

24.3

25.2

27.6

-23

.724

.626

.9-

22.5

23.3

25.6

-20

.821

.623

.7-

S/T

0.70

0.59

0.41

-0.

730.

610.

42-

0.75

0.62

0.43

-0.

770.

640.

45-

0.80

0.67

0.46

-0.

810.

670.

47-

∆T19

1612

-19

1612

-19

1613

-19

1713

-19

1612

-18

1512

-kW

1.87

1.90

1.96

-2.

002.

042.

10-

2.11

2.15

2.22

-2.

212.

262.

32-

2.30

2.34

2.41

-2.

372.

422.

49-

Amps

6.8

6.9

7.1

-7.

37.

57.

7-

7.9

8.1

8.4

-8.

58.

79.

0-

9.0

9.2

9.5

-9.

59.

810

.1-

Hi P

R21

423

024

3-

240

259

273

-27

329

431

1-

311

335

354

-35

037

739

8-

387

416

440

-Lo

PR

104

110

120

-11

011

712

7-

114

121

132

-12

012

713

9-

125

133

146

-13

013

815

1-

1000

MBh

27.6

28.6

31.3

-26

.927

.930

.6-

26.3

27.3

29.9

-25

.726

.629

.1-

24.4

25.3

27.7

-22

.623

.425

.6-

S/T

0.73

0.61

0.42

-0.

750.

630.

44-

0.77

0.65

0.45

-0.

800.

670.

46-

0.83

0.69

0.48

-0.

840.

700.

48-

∆T18

1612

-19

1612

-19

1612

-19

1612

-19

1612

-17

1511

-kW

1.91

1.95

2.00

-2.

042.

082.

14-

2.16

2.20

2.27

-2.

262.

312.

38-

2.35

2.40

2.47

-2.

432.

482.

55-

Amps

6.9

7.1

7.3

-7.

57.

77.

9-

8.2

8.3

8.6

-8.

78.

99.

2-

9.3

9.5

9.8

-9.

810

.110

.4-

Hi P

R22

123

825

1-

248

267

282

-28

230

332

0-

321

345

365

-36

138

841

0-

399

429

453

-Lo

PR

107

114

124

-11

312

013

1-

117

125

136

-12

313

114

3-

129

138

150

-13

414

215

5-

1125

MBh

28.4

29.5

32.3

-27

.828

.831

.5-

27.1

28.1

30.8

-26

.427

.430

.0-

25.1

26.0

28.5

-23

.324

.126

.4-

S/T

0.76

0.64

0.44

-0.

790.

660.

46-

0.81

0.68

0.47

-0.

840.

700.

48-

0.87

0.73

0.50

-0.

880.

730.

51-

∆T18

1512

-18

1612

-18

1612

-18

1612

-18

1512

-17

1411

-kW

1.92

1.96

2.02

-2.

062.

102.

16-

2.18

2.22

2.29

-2.

282.

332.

40-

2.37

2.42

2.49

-2.

452.

502.

57-

Amps

7.0

7.2

7.4

-7.

67.

88.

0-

8.2

8.4

8.7

-8.

89.

09.

3-

9.4

9.6

9.9

-9.

910

.110

.5-

Hi P

R22

324

025

3-

250

269

284

-28

530

632

3-

324

349

368

-36

539

241

4-

403

434

458

-Lo

PR

108

115

125

-11

412

113

3-

119

126

138

-12

513

314

5-

131

139

152

-13

514

415

7-

75

875

MBh

25.9

26.7

28.9

31.0

25.3

26.0

28.2

30.3

24.7

25.4

27.5

29.5

24.1

24.8

26.8

28.8

22.9

23.6

25.5

27.4

21.2

21.8

23.6

25.4

S/T

0.80

0.71

0.54

0.35

0.83

0.74

0.56

0.36

0.85

0.76

0.57

0.37

0.88

0.78

0.59

0.38

0.91

0.81

0.62

0.40

0.92

0.82

0.62

0.40

∆T22

2016

1122

2017

1122

2017

1122

2017

1222

2016

1120

1915

11kW

1.88

1.92

1.97

2.03

2.01

2.05

2.11

2.17

2.13

2.17

2.23

2.30

2.23

2.27

2.34

2.41

2.31

2.36

2.43

2.51

2.39

2.44

2.51

2.59

Amps

6.8

7.0

7.2

7.5

7.4

7.5

7.8

8.1

8.0

8.2

8.5

8.8

8.5

8.8

9.0

9.4

9.1

9.3

9.6

10.0

9.6

9.9

10.2

10.6

Hi P

R21

623

324

625

624

326

127

628

827

629

731

432

731

433

835

737

335

438

140

241

939

142

144

446

3Lo

PR

105

111

122

130

111

118

129

137

115

122

134

142

121

129

140

150

127

135

147

157

131

139

152

162

1000

MBh

28.1

28.9

31.3

33.6

27.4

28.2

30.5

32.8

26.8

27.5

29.8

32.0

26.1

26.9

29.1

31.2

24.8

25.5

27.6

29.7

23.0

23.6

25.6

27.5

S/T

0.83

0.74

0.56

0.36

0.86

0.77

0.58

0.37

0.88

0.79

0.60

0.38

0.91

0.81

0.61

0.40

0.94

0.84

0.64

0.41

0.95

0.85

0.64

0.41

∆T21

2016

1122

2016

1122

2016

1122

2016

1121

2016

1120

1815

10kW

1.92

1.96

2.02

2.08

2.06

2.10

2.16

2.22

2.18

2.22

2.29

2.36

2.28

2.33

2.40

2.47

2.37

2.42

2.49

2.57

2.45

2.50

2.57

2.66

Amps

7.0

7.2

7.4

7.7

7.6

7.8

8.0

8.3

8.2

8.4

8.7

9.0

8.8

9.0

9.3

9.7

9.4

9.6

9.9

10.3

9.9

10.2

10.5

10.9

Hi P

R22

324

025

326

425

026

928

429

728

530

632

333

732

434

936

838

436

539

241

443

240

343

445

847

8Lo

PR

108

115

125

134

114

121

133

141

119

126

138

147

125

133

145

154

131

139

152

162

135

144

157

167

1125

MBh

28.9

29.8

32.2

34.6

28.2

29.1

31.5

33.8

27.6

28.4

30.7

33.0

26.9

27.7

30.0

32.2

25.5

26.3

28.5

30.5

23.7

24.4

26.4

28.3

S/T

0.87

0.78

0.59

0.38

0.90

0.80

0.61

0.39

0.92

0.82

0.62

0.40

0.95

0.85

0.64

0.41

0.99

0.88

0.67

0.43

1.00

0.89

0.67

0.43

∆T20

1915

1121

1916

1121

1916

1121

1916

1121

1916

1119

1815

10kW

1.94

1.97

2.03

2.09

2.07

2.11

2.18

2.24

2.19

2.24

2.30

2.37

2.30

2.35

2.42

2.49

2.39

2.44

2.51

2.59

2.47

2.52

2.60

2.68

Amps

7.1

7.2

7.5

7.8

7.6

7.8

8.1

8.4

8.3

8.5

8.8

9.1

8.9

9.1

9.4

9.7

9.4

9.7

10.0

10.4

10.0

10.2

10.6

11.0

Hi P

R22

524

225

626

725

327

228

730

028

730

932

734

132

735

237

238

836

839

641

943

740

743

846

248

2Lo

PR

109

116

127

135

115

123

134

143

120

127

139

148

126

134

146

156

132

140

153

163

136

145

158

169

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

SS-DX16SA www.daikincomfort.com 9

Expanded Cooling Data — DX16SA0301A* / CA*F3743*6D*+EEP+TXV (cont.)

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

80

875

MBh

26.4

26.9

28.8

30.8

25.7

26.3

28.1

30.0

25.1

25.7

27.4

29.3

24.5

25.1

26.8

28.6

23.3

23.8

25.4

27.2

21.6

22.0

23.6

25.2

S/T

0.88

0.82

0.67

0.50

0.91

0.85

0.69

0.52

0.93

0.87

0.71

0.53

0.96

0.90

0.73

0.55

1.00

0.93

0.76

0.57

1.00

0.94

0.77

0.57

∆T24

2320

1625

2420

1625

2420

1625

2421

1624

2320

1623

2219

15kW

1.90

1.93

1.99

2.04

2.03

2.07

2.13

2.19

2.14

2.19

2.25

2.32

2.25

2.29

2.36

2.43

2.33

2.38

2.45

2.53

2.41

2.46

2.53

2.61

Amps

6.9

7.0

7.3

7.5

7.4

7.6

7.9

8.2

8.1

8.3

8.5

8.9

8.6

8.8

9.1

9.5

9.2

9.4

9.7

10.1

9.7

10.0

10.3

10.7

Hi P

R21

923

524

825

924

526

427

929

127

930

031

733

131

834

236

137

635

738

540

642

439

542

544

946

8Lo

PR

106

113

123

131

112

119

130

138

116

124

135

144

122

130

142

151

128

136

149

158

132

141

154

164

1000

MBh

28.6

29.2

31.2

33.3

27.9

28.5

30.5

32.6

27.2

27.8

29.7

31.8

26.6

27.1

29.0

31.0

25.2

25.8

27.6

29.5

23.4

23.9

25.5

27.3

S/T

0.91

0.85

0.69

0.52

0.94

0.88

0.72

0.54

0.96

0.90

0.74

0.55

1.00

0.93

0.76

0.57

1.00

0.97

0.79

0.59

1.00

0.98

0.80

0.59

∆T24

2320

1624

2320

1624

2320

1624

2320

1623

2320

1621

2119

15kW

1.94

1.97

2.03

2.09

2.07

2.11

2.18

2.24

2.19

2.24

2.30

2.37

2.30

2.35

2.42

2.49

2.39

2.44

2.51

2.59

2.47

2.52

2.60

2.68

Amps

7.1

7.2

7.5

7.8

7.6

7.8

8.1

8.4

8.3

8.5

8.8

9.1

8.9

9.1

9.4

9.7

9.4

9.7

10.0

10.4

10.0

10.2

10.6

11.0

Hi P

R22

524

225

626

725

327

228

730

028

730

932

734

132

735

237

238

836

839

641

943

740

743

846

348

2Lo

PR

109

116

127

135

115

123

134

143

120

127

139

148

126

134

146

156

132

140

153

163

136

145

158

169

1125

MBh

29.4

30.1

32.1

34.3

28.7

29.4

31.4

33.5

28.0

28.7

30.6

32.7

27.4

28.0

29.9

31.9

26.0

26.6

28.4

30.3

24.1

24.6

26.3

28.1

S/T

0.95

0.89

0.73

0.54

1.00

0.93

0.75

0.56

1.00

0.95

0.77

0.58

1.00

1.00

0.80

0.60

1.00

1.00

0.83

0.62

1.00

1.00

0.83

0.62

∆T23

2219

1523

2219

1523

2219

1522

2319

1621

2219

1520

2018

14kW

1.95

1.99

2.05

2.11

2.09

2.13

2.19

2.26

2.21

2.25

2.32

2.39

2.32

2.36

2.44

2.51

2.41

2.46

2.53

2.61

2.48

2.54

2.62

2.70

Amps

7.1

7.3

7.5

7.8

7.7

7.9

8.2

8.5

8.4

8.6

8.9

9.2

9.0

9.2

9.5

9.8

9.5

9.8

10.1

10.5

10.1

10.3

10.7

11.1

Hi P

R22

824

525

927

025

527

529

030

329

031

233

034

433

135

637

639

237

240

042

344

141

144

246

748

7Lo

PR

110

117

128

136

116

124

135

144

121

129

141

150

127

135

148

157

133

142

155

165

138

147

160

170

85

875

MBh

26.8

27.3

28.6

30.5

26.2

26.7

28.0

29.8

25.6

26.1

27.3

29.1

24.9

25.4

26.6

28.4

23.7

24.2

25.3

27.0

22.0

22.4

23.4

25.0

S/T

0.92

0.89

0.80

0.65

0.95

0.92

0.83

0.67

0.98

0.94

0.85

0.69

1.00

0.97

0.88

0.71

1.00

1.00

0.91

0.74

1.00

1.00

0.92

0.74

∆T26

2524

2126

2624

2126

2624

2126

2625

2125

2524

2123

2423

20kW

1.91

1.95

2.00

2.06

2.04

2.08

2.14

2.21

2.16

2.20

2.27

2.34

2.26

2.31

2.38

2.45

2.35

2.40

2.47

2.55

2.43

2.48

2.55

2.63

Amps

6.9

7.1

7.3

7.6

7.5

7.7

7.9

8.2

8.1

8.3

8.6

8.9

8.7

8.9

9.2

9.6

9.3

9.5

9.8

10.2

9.8

10.1

10.4

10.8

Hi P

R22

123

825

126

224

826

728

129

428

230

332

033

432

134

536

538

036

138

841

042

839

942

945

347

3Lo

PR

107

114

124

132

113

120

131

140

117

125

136

145

123

131

143

153

129

137

150

160

134

142

155

165

1000

MBh

29.1

29.6

31.0

33.1

28.4

28.9

30.3

32.3

27.7

28.2

29.6

31.6

27.0

27.6

28.9

30.8

25.7

26.2

27.4

29.2

23.8

24.2

25.4

27.1

S/T

0.95

0.92

0.83

0.67

0.99

0.95

0.86

0.70

1.00

0.98

0.88

0.71

1.00

1.00

0.91

0.74

1.00

1.00

0.94

0.77

1.00

1.00

0.95

0.77

∆T25

2524

2026

2524

2125

2524

2125

2524

2124

2424

2122

2222

19kW

1.95

1.99

2.05

2.11

2.09

2.13

2.19

2.26

2.21

2.25

2.32

2.39

2.32

2.36

2.44

2.51

2.41

2.46

2.53

2.61

2.48

2.54

2.62

2.70

Amps

7.1

7.3

7.5

7.8

7.7

7.9

8.2

8.5

8.4

8.6

8.9

9.2

9.0

9.2

9.5

9.8

9.5

9.8

10.1

10.5

10.1

10.3

10.7

11.1

Hi P

R22

824

525

927

025

527

529

030

329

031

233

034

433

135

637

639

237

240

042

344

141

144

246

748

7Lo

PR

110

117

128

136

116

124

135

144

121

129

141

150

127

135

148

157

133

142

155

165

138

147

160

170

1125

MBh

29.9

30.5

31.9

34.1

29.2

29.8

31.2

33.3

28.5

29.1

30.5

32.5

27.8

28.4

29.7

31.7

26.4

27.0

28.2

30.1

24.5

25.0

26.2

27.9

S/T

1.00

0.96

0.87

0.70

1.00

1.00

0.90

0.73

1.00

1.00

0.92

0.75

1.00

1.00

0.95

0.77

1.00

1.00

0.99

0.80

1.00

1.00

1.00

0.81

∆T24

2423

2024

2423

2023

2423

2023

2323

2022

2223

2020

2021

18kW

1.97

2.00

2.06

2.12

2.10

2.15

2.21

2.28

2.23

2.27

2.34

2.41

2.33

2.38

2.45

2.53

2.43

2.48

2.55

2.63

2.50

2.56

2.64

2.72

Amps

7.2

7.4

7.6

7.9

7.8

8.0

8.2

8.5

8.5

8.7

8.9

9.3

9.0

9.3

9.6

9.9

9.6

9.9

10.2

10.6

10.2

10.4

10.8

11.2

Hi P

R23

024

726

127

225

827

829

330

629

331

633

334

833

435

938

039

637

640

442

744

541

544

747

249

2Lo

PR

111

118

129

138

118

125

137

145

122

130

142

151

128

137

149

159

135

143

156

166

139

148

162

172

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

10 www.daikincomfort.com SS-DX16SA

Expanded Cooling Data — DX16SA0311A* / CA*F3743*6D*+EEP+TXV

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

70

875

MBh

29.1

29.5

30.4

-28

.829

.230

.1-

28.1

28.5

29.4

-26

.827

.228

.0-

25.2

25.6

26.5

-23

.724

.125

.0-

S/T

0.62

0.54

0.40

-0.

630.

550.

41-

0.65

0.57

0.44

-0.

670.

590.

46-

1.00

0.62

0.48

-1.

000.

670.

53-

∆T20

1815

-20

1815

-20

1815

-20

1815

-20

1814

-21

1915

-kW

1.67

1.67

1.67

-1.

861.

861.

86-

2.07

2.07

2.07

-2.

302.

302.

30-

2.55

2.55

2.55

-2.

852.

852.

85-

Amps

6.0

6.0

6.0

-6.

96.

86.

8-

7.8

7.8

7.8

-8.

98.

88.

8-

10.0

10.0

10.0

-11

.411

.411

.4-

Hi P

R24

124

224

4-

280

281

282

-31

932

132

2-

362

363

365

-40

941

041

2-

458

459

461

-Lo

PR

123

125

128

-13

013

213

5-

137

139

142

-14

314

414

7-

148

150

153

-15

515

615

9-

1000

MBh

29.5

29.9

30.8

-29

.229

.630

.5-

28.5

28.9

29.7

-27

.227

.628

.4-

25.6

26.0

26.8

-24

.124

.525

.4-

S/T

0.68

0.60

0.47

-0.

690.

610.

47-

0.71

0.64

0.50

-1.

000.

660.

52-

1.00

0.68

0.54

-1.

000.

730.

59-

∆T19

1713

-19

1713

-19

1714

-19

1713

-18

1713

-20

1814

-kW

1.68

1.68

1.68

-1.

871.

871.

87-

2.08

2.08

2.08

-2.

312.

312.

31-

2.56

2.56

2.56

-2.

862.

862.

86-

Amps

6.0

6.0

6.0

-6.

96.

96.

9-

7.9

7.9

7.8

-8.

98.

98.

9-

10.1

10.1

10.0

-11

.411

.411

.4-

Hi P

R24

324

524

6-

282

283

284

-32

232

332

4-

364

366

367

-41

141

241

4-

460

461

463

-Lo

PR

125

126

129

-13

213

413

7-

139

140

144

-14

414

614

9-

150

151

154

-15

715

816

1-

1125

MBh

29.9

30.3

31.2

-29

.730

.131

.0-

28.9

29.3

30.2

-27

.628

.028

.9-

26.0

26.4

27.3

-24

.625

.025

.8-

S/T

0.72

0.64

0.50

-0.

720.

650.

51-

0.75

0.67

0.53

-1.

000.

690.

55-

1.00

0.71

0.57

-1.

000.

770.

63-

∆T18

1613

-18

1612

-18

1613

-18

1612

-17

1612

-19

1713

-kW

1.69

1.69

1.69

-1.

881.

881.

88-

2.09

2.09

2.09

-2.

322.

322.

31-

2.57

2.57

2.57

-2.

872.

872.

87-

Amps

6.1

6.1

6.1

-6.

96.

96.

9-

7.9

7.9

7.9

-8.

98.

98.

9-

10.1

10.1

10.1

-11

.511

.511

.4-

Hi P

R24

524

724

8-

284

285

286

-32

332

532

6-

366

368

369

-41

341

441

6-

462

463

465

-Lo

PR

127

128

131

-13

413

613

9-

141

142

146

-14

614

815

1-

152

153

156

-15

916

016

3-

75

875

MBh

29.1

29.5

30.4

31.7

28.9

29.3

30.1

31.5

28.1

28.5

29.4

30.7

26.8

27.2

28.1

29.4

25.2

25.6

26.5

27.8

23.7

24.1

25.0

26.3

S/T

0.75

0.68

0.54

0.39

0.76

0.68

0.54

0.40

1.00

0.71

0.57

0.42

1.00

0.73

0.59

0.44

1.00

0.75

0.61

0.46

1.00

1.00

0.66

0.52

∆T24

2219

1524

2219

1524

2219

1524

2219

1524

2218

1525

2319

16kW

1.67

1.67

1.67

1.68

1.86

1.86

1.86

1.87

2.07

2.07

2.07

2.08

2.30

2.30

2.29

2.31

2.55

2.55

2.55

2.56

2.85

2.85

2.85

2.86

Amps

6.0

6.0

6.0

6.0

6.8

6.8

6.8

6.9

7.8

7.8

7.8

7.9

8.9

8.8

8.8

8.9

10.0

10.0

10.0

10.1

11.4

11.4

11.4

11.4

Hi P

R24

224

324

424

928

028

128

228

732

032

132

232

736

336

436

537

040

941

041

241

645

845

946

146

5Lo

PR

123

125

128

133

131

132

135

140

137

139

142

147

143

144

147

153

148

150

153

158

155

156

160

165

1000

MBh

29.5

29.9

30.8

32.1

29.2

29.6

30.5

31.8

28.5

28.9

29.8

31.1

27.2

27.6

28.4

29.8

25.6

26.0

26.9

28.2

24.1

24.5

25.4

26.7

S/T

0.81

0.74

0.60

0.45

0.82

0.74

0.60

0.46

1.00

0.77

0.63

0.48

1.00

0.79

0.65

0.50

1.00

0.81

0.67

0.53

1.00

1.00

0.73

0.58

∆T23

2118

1423

2117

1423

2118

1423

2117

1422

2117

1424

2218

15kW

1.68

1.68

1.68

1.69

1.87

1.87

1.87

1.88

2.08

2.08

2.08

2.09

2.31

2.31

2.30

2.32

2.56

2.56

2.56

2.57

2.86

2.86

2.86

2.87

Amps

6.0

6.0

6.0

6.1

6.9

6.9

6.9

6.9

7.9

7.8

7.8

7.9

8.9

8.9

8.9

8.9

10.1

10.1

10.0

10.1

11.4

11.4

11.4

11.5

Hi P

R24

424

524

625

128

228

328

528

932

232

332

432

936

536

636

737

241

141

241

441

846

046

246

346

7Lo

PR

125

126

129

135

132

134

137

142

139

140

144

149

144

146

149

154

150

151

155

160

157

158

161

167

1125

MBh

30.0

30.4

31.2

32.6

29.7

30.1

31.0

32.3

28.9

29.3

30.2

31.5

27.6

28.0

28.9

30.2

26.0

26.4

27.3

28.6

24.6

25.0

25.9

27.2

S/T

0.85

0.77

0.63

0.49

1.00

0.78

0.64

0.49

1.00

0.80

0.66

0.52

1.00

0.82

0.68

0.54

1.00

0.85

0.71

0.56

1.00

1.00

0.76

0.61

∆T22

2017

1322

2017

1322

2017

1322

2017

1322

2016

1323

2117

14kW

1.69

1.69

1.69

1.70

1.88

1.88

1.87

1.89

2.09

2.09

2.08

2.10

2.32

2.32

2.31

2.33

2.57

2.57

2.57

2.58

2.87

2.87

2.86

2.88

Amps

6.1

6.1

6.0

6.1

6.9

6.9

6.9

7.0

7.9

7.9

7.9

7.9

8.9

8.9

8.9

9.0

10.1

10.1

10.1

10.1

11.5

11.5

11.4

11.5

Hi P

R24

624

724

825

328

428

528

729

132

432

532

633

136

736

836

937

441

341

441

642

046

246

446

546

9Lo

PR

127

128

132

137

134

136

139

144

141

142

146

151

146

148

151

156

152

153

157

162

159

160

163

169

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

SS-DX16SA www.daikincomfort.com 11

Expanded Cooling Data — DX16SA0311A* / CA*F3743*6D*+EEP+TXV (cont.)

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

80

875

MBh

29.3

29.7

30.5

31.9

29.0

29.4

30.3

31.6

28.2

28.7

29.5

30.9

26.9

27.3

28.2

29.5

25.3

25.8

26.6

27.9

23.9

24.3

25.2

26.5

S/T

1.00

0.80

0.66

0.52

1.00

0.81

0.67

0.52

1.00

0.84

0.70

0.55

1.00

0.86

0.72

0.57

1.00

1.00

0.74

0.59

1.00

1.00

0.79

0.65

∆T28

2623

1928

2623

1928

2623

1928

2623

1928

2622

1929

2724

20kW

1.67

1.67

1.67

1.68

1.86

1.86

1.86

1.87

2.07

2.07

2.07

2.08

2.30

2.30

2.30

2.31

2.55

2.55

2.55

2.56

2.85

2.85

2.85

2.86

Amps

6.0

6.0

6.0

6.0

6.9

6.8

6.8

6.9

7.8

7.8

7.8

7.9

8.9

8.8

8.8

8.9

10.0

10.0

10.0

10.1

11.4

11.4

11.4

11.4

Hi P

R24

224

324

524

928

028

128

328

732

032

132

332

736

336

436

637

040

941

041

241

645

946

046

246

6Lo

PR

124

125

128

133

131

133

136

141

138

139

142

148

143

145

148

153

149

150

153

158

155

157

160

165

1000

MBh

29.6

30.1

30.9

32.3

29.4

29.8

30.7

32.0

28.6

29.0

29.9

31.2

27.3

27.7

28.6

29.9

25.7

26.1

27.0

28.3

24.3

24.7

25.5

26.9

S/T

1.00

0.87

0.73

0.58

1.00

0.87

0.73

0.59

1.00

0.90

0.76

0.61

1.00

1.00

0.78

0.63

1.00

1.00

0.80

0.65

1.00

1.00

0.85

0.71

∆T27

2522

1827

2522

1827

2522

1827

2521

1827

2521

1828

2622

19kW

1.68

1.68

1.68

1.69

1.87

1.87

1.87

1.88

2.08

2.08

2.08

2.09

2.31

2.31

2.30

2.32

2.56

2.56

2.56

2.57

2.86

2.86

2.86

2.87

Amps

6.0

6.0

6.0

6.1

6.9

6.9

6.9

6.9

7.9

7.9

7.8

7.9

8.9

8.9

8.9

8.9

10.1

10.1

10.0

10.1

11.4

11.4

11.4

11.5

Hi P

R24

424

524

725

128

228

328

528

932

232

332

532

936

536

636

837

241

141

341

441

846

146

246

446

8Lo

PR

125

127

130

135

133

134

138

143

139

141

144

149

145

146

150

155

150

152

155

160

157

159

162

167

1125

MBh

30.1

30.5

31.4

32.7

29.8

30.3

31.1

32.5

29.1

29.5

30.4

31.7

27.8

28.2

29.1

30.4

26.2

26.6

27.5

28.8

24.7

25.1

26.0

27.3

S/T

1.00

0.90

0.76

0.61

1.00

0.91

0.77

0.62

1.00

0.93

0.79

0.65

1.00

1.00

0.81

0.67

1.00

1.00

0.84

0.69

1.00

1.00

0.89

0.74

∆T26

2421

1726

2421

1726

2421

1726

2421

1726

2420

1727

2521

18kW

1.69

1.69

1.69

1.70

1.88

1.88

1.88

1.89

2.09

2.09

2.09

2.10

2.32

2.32

2.31

2.33

2.57

2.57

2.57

2.58

2.87

2.87

2.86

2.88

Amps

6.1

6.1

6.1

6.1

6.9

6.9

6.9

7.0

7.9

7.9

7.9

7.9

8.9

8.9

8.9

9.0

10.1

10.1

10.1

10.1

11.5

11.5

11.4

11.5

Hi P

R24

624

724

925

328

428

528

729

132

432

532

733

136

736

837

037

441

341

541

642

046

346

446

647

0Lo

PR

127

129

132

137

135

136

140

145

141

143

146

151

147

148

152

157

152

154

157

162

159

161

164

169

85

875

MBh

29.8

30.2

31.0

32.4

29.5

29.9

30.8

32.1

28.7

29.1

30.0

31.3

27.4

27.8

28.7

30.0

25.8

26.2

27.1

28.4

24.4

24.8

25.7

27.0

S/T

1.00

0.91

0.77

0.62

1.00

0.91

0.77

0.63

1.00

1.00

0.80

0.65

1.00

1.00

0.82

0.67

1.00

1.00

0.84

0.70

1.00

1.00

1.00

0.75

∆T32

3026

2331

3026

2332

3026

2331

3026

2331

2926

2232

3127

24kW

1.68

1.68

1.67

1.69

1.87

1.86

1.86

1.88

2.08

2.07

2.07

2.09

2.30

2.30

2.30

2.31

2.56

2.56

2.55

2.57

2.86

2.85

2.85

2.86

Amps

6.0

6.0

6.0

6.1

6.9

6.9

6.8

6.9

7.8

7.8

7.8

7.9

8.9

8.9

8.9

8.9

10.0

10.0

10.0

10.1

11.4

11.4

11.4

11.4

Hi P

R24

324

424

625

028

128

228

428

832

132

232

432

836

436

536

737

141

141

241

341

846

046

146

346

7Lo

PR

125

127

130

135

133

134

138

143

139

141

144

149

145

147

150

155

150

152

155

160

157

159

162

167

1000

MBh

30.1

30.5

31.4

32.7

29.9

30.3

31.2

32.5

29.1

29.5

30.4

31.7

27.8

28.2

29.1

30.4

26.2

26.6

27.5

28.8

24.8

25.2

26.0

27.4

S/T

1.00

0.97

0.83

0.68

1.00

1.00

0.84

0.69

1.00

1.00

0.86

0.72

1.00

1.00

0.88

0.74

1.00

1.00

0.90

0.76

1.00

1.00

1.00

0.81

∆T30

2925

2230

2925

2231

2925

2230

2925

2230

2825

2131

2926

22kW

1.69

1.69

1.68

1.70

1.88

1.87

1.87

1.89

2.09

2.08

2.08

2.10

2.31

2.31

2.31

2.32

2.57

2.57

2.56

2.58

2.87

2.86

2.86

2.87

Amps

6.1

6.0

6.0

6.1

6.9

6.9

6.9

7.0

7.9

7.9

7.9

7.9

8.9

8.9

8.9

9.0

10.1

10.1

10.1

10.1

11.4

11.4

11.4

11.5

Hi P

R24

524

624

825

228

328

428

629

032

332

432

633

036

636

736

937

341

341

441

542

046

246

346

546

9Lo

PR

127

129

132

137

135

136

139

145

141

143

146

151

147

148

151

157

152

154

157

162

159

161

164

169

1125

MBh

30.6

31.0

31.9

33.2

30.3

30.7

31.6

32.9

29.6

30.0

30.9

32.2

28.3

28.7

29.5

30.9

26.7

27.1

28.0

29.3

25.2

25.6

26.5

27.8

S/T

1.00

1.00

0.86

0.72

1.00

1.00

0.87

0.72

1.00

1.00

0.90

0.75

1.00

1.00

0.92

0.77

1.00

1.00

1.00

0.79

1.00

1.00

1.00

0.85

∆T29

2824

2129

2824

2130

2824

2129

2824

2129

2724

2030

2825

22kW

1.70

1.69

1.69

1.71

1.88

1.88

1.88

1.89

2.09

2.09

2.09

2.10

2.32

2.32

2.32

2.33

2.58

2.57

2.57

2.59

2.87

2.87

2.87

2.88

Amps

6.1

6.1

6.1

6.1

7.0

6.9

6.9

7.0

7.9

7.9

7.9

8.0

9.0

8.9

8.9

9.0

10.1

10.1

10.1

10.2

11.5

11.5

11.5

11.5

Hi P

R24

724

825

025

428

528

628

829

232

532

632

833

236

836

937

137

541

541

641

742

246

446

546

747

1Lo

PR

129

131

134

139

137

138

141

147

143

145

148

153

149

150

153

159

154

156

159

164

161

163

166

171

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

12 www.daikincomfort.com SS-DX16SA

Expanded Cooling Data — DX16SA0361A* / CA*F4860*6D*+EEP+TXV

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

70

1050

MBh

30.6

31.7

34.7

-29

.830

.933

.9-

29.1

30.2

33.1

-28

.429

.532

.3-

27.0

28.0

30.7

-25

.025

.928

.4-

S/T

0.73

0.61

0.42

-0.

760.

630.

44-

0.78

0.65

0.45

-0.

800.

670.

47-

0.84

0.70

0.48

-0.

840.

700.

49-

∆T20

1713

-20

1713

-20

1713

-20

1713

-20

1713

-18

1612

-kW

2.23

2.27

2.34

-2.

392.

442.

51-

2.53

2.58

2.66

-2.

652.

702.

79-

2.75

2.81

2.90

-2.

842.

902.

99-

Amps

8.1

8.3

8.5

-8.

78.

99.

2-

9.5

9.7

10.0

-10

.110

.410

.7-

10.8

11.1

11.4

-11

.511

.712

.1-

Hi P

R21

923

624

9-

246

265

280

-28

030

131

8-

319

343

362

-35

938

640

8-

396

427

450

-Lo

PR

103

109

120

-10

911

612

6-

113

120

131

-11

912

613

8-

124

132

144

-12

913

714

9-

1200

MBh

33.1

34.3

37.6

-32

.333

.536

.7-

31.6

32.7

35.8

-30

.831

.935

.0-

29.3

30.3

33.2

-27

.128

.130

.8-

S/T

0.76

0.64

0.44

-0.

790.

660.

46-

0.81

0.68

0.47

-0.

830.

700.

48-

0.87

0.72

0.50

-0.

870.

730.

51-

∆T19

1713

-20

1713

-20

1713

-20

1713

-19

1713

-18

1612

-kW

2.28

2.33

2.39

-2.

442.

492.

57-

2.59

2.64

2.72

-2.

712.

772.

85-

2.82

2.88

2.97

-2.

912.

973.

07-

Amps

8.3

8.5

8.8

-9.

09.

29.

5-

9.8

10.0

10.3

-10

.410

.711

.1-

11.1

11.4

11.8

-11

.812

.112

.5-

Hi P

R22

624

325

7-

254

273

288

-28

931

132

8-

329

354

374

-37

039

842

0-

409

440

464

-Lo

PR

106

113

123

-11

211

913

0-

116

124

135

-12

213

014

2-

128

136

149

-13

314

115

4-

1350

MBh

34.1

35.3

38.7

-33

.334

.537

.8-

32.5

33.7

36.9

-31

.732

.936

.0-

30.1

31.2

34.2

-27

.928

.931

.7-

S/T

0.80

0.67

0.46

-0.

830.

690.

48-

0.85

0.71

0.49

-0.

870.

730.

51-

0.91

0.76

0.53

-0.

920.

760.

53-

∆T19

1612

-19

1612

-19

1612

-19

1612

-19

1612

-17

1511

-kW

2.30

2.34

2.41

-2.

462.

512.

59-

2.61

2.66

2.74

-2.

732.

792.

88-

2.84

2.90

2.99

-2.

943.

003.

09-

Amps

8.4

8.6

8.9

-9.

19.

39.

6-

9.8

10.1

10.4

-10

.510

.811

.2-

11.2

11.5

11.9

-11

.912

.212

.6-

Hi P

R22

824

626

0-

256

276

291

-29

231

433

1-

332

357

377

-37

440

242

4-

413

444

469

-Lo

PR

107

114

124

-11

312

013

1-

118

125

137

-12

413

114

4-

130

138

150

-13

414

315

6-

75

1050

MBh

31.1

32.0

34.6

37.2

30.4

31.3

33.8

36.3

29.6

30.5

33.0

35.4

28.9

29.8

32.2

34.6

27.5

28.3

30.6

32.8

25.4

26.2

28.4

30.4

S/T

0.83

0.75

0.56

0.36

0.86

0.77

0.58

0.38

0.89

0.79

0.60

0.39

0.91

0.82

0.62

0.40

0.95

0.85

0.64

0.41

0.96

0.86

0.65

0.42

∆T23

2117

1223

2117

1223

2117

1223

2117

1223

2117

1221

2016

11kW

2.25

2.29

2.36

2.43

2.41

2.45

2.53

2.60

2.55

2.60

2.68

2.76

2.67

2.73

2.81

2.90

2.78

2.83

2.92

3.01

2.87

2.93

3.02

3.11

Amps

8.1

8.3

8.6

8.9

8.8

9.0

9.3

9.7

9.6

9.8

10.1

10.5

10.2

10.5

10.8

11.3

10.9

11.2

11.6

12.0

11.6

11.9

12.3

12.7

Hi P

R22

223

925

226

324

926

828

329

528

330

432

133

532

234

736

638

236

239

041

243

040

043

145

547

5Lo

PR

104

111

121

129

110

117

128

136

114

121

133

141

120

128

139

148

126

134

146

155

130

138

151

161

1200

MBh

33.7

34.7

37.5

40.3

32.9

33.9

36.6

39.3

32.1

33.1

35.8

38.4

31.3

32.2

34.9

37.5

29.8

30.6

33.2

35.6

27.6

28.4

30.7

33.0

S/T

0.86

0.77

0.59

0.38

0.90

0.80

0.61

0.39

0.92

0.82

0.62

0.40

0.95

0.85

0.64

0.41

0.98

0.88

0.67

0.43

0.99

0.89

0.67

0.43

∆T22

2117

1223

2117

1223

2117

1223

2117

1222

2117

1221

1916

11kW

2.30

2.34

2.41

2.48

2.46

2.51

2.59

2.67

2.61

2.66

2.74

2.83

2.73

2.79

2.88

2.97

2.84

2.90

2.99

3.09

2.94

3.00

3.09

3.19

Amps

8.4

8.6

8.9

9.2

9.1

9.3

9.6

10.0

9.9

10.1

10.4

10.8

10.5

10.8

11.2

11.6

11.2

11.5

11.9

12.3

11.9

12.2

12.6

13.1

Hi P

R22

824

626

027

125

627

629

130

429

231

433

134

633

235

737

739

437

440

242

544

341

344

446

948

9Lo

PR

107

114

124

133

113

120

131

140

118

125

137

146

124

131

144

153

130

138

150

160

134

143

156

166

1350

MBh

34.7

35.7

38.6

41.5

33.9

34.9

37.7

40.5

33.1

34.0

36.9

39.6

32.3

33.2

36.0

38.6

30.6

31.6

34.2

36.7

28.4

29.2

31.6

34.0

S/T

0.91

0.81

0.61

0.39

0.94

0.84

0.64

0.41

0.96

0.86

0.65

0.42

0.99

0.89

0.67

0.43

1.00

0.92

0.70

0.45

1.00

0.93

0.70

0.45

∆T21

2016

1122

2016

1122

2016

1122

2016

1121

2016

1119

1915

10kW

2.32

2.36

2.43

2.50

2.48

2.53

2.61

2.69

2.63

2.68

2.76

2.85

2.76

2.81

2.90

2.99

2.86

2.93

3.02

3.11

2.96

3.02

3.12

3.22

Amps

8.4

8.7

8.9

9.3

9.1

9.4

9.7

10.0

9.9

10.2

10.5

10.9

10.6

10.9

11.3

11.7

11.3

11.6

12.0

12.5

12.0

12.3

12.7

13.2

Hi P

R23

124

826

227

425

927

929

430

729

531

733

534

933

536

138

139

837

740

642

944

741

744

947

449

4Lo

PR

108

115

126

134

114

122

133

141

119

126

138

147

125

133

145

154

131

139

152

162

135

144

157

167

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

SS-DX16SA www.daikincomfort.com 13

Expanded Cooling Data — DX16SA0361A* / CA*F4860*6D*+EEP+TXV (cont.)

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

80

1050

MBh

31.6

32.3

34.5

36.9

30.9

31.6

33.7

36.1

30.2

30.8

32.9

35.2

29.4

30.1

32.1

34.3

28.0

28.6

30.5

32.6

25.9

26.5

28.3

30.2

S/T

0.91

0.86

0.70

0.52

0.95

0.89

0.72

0.54

0.97

0.91

0.74

0.55

1.00

0.94

0.77

0.57

1.04

0.98

0.79

0.59

1.05

0.98

0.80

0.60

∆T25

2421

1726

2521

1726

2521

1726

2522

1725

2421

1724

2320

16kW

2.26

2.31

2.38

2.45

2.42

2.47

2.55

2.62

2.57

2.62

2.70

2.78

2.69

2.75

2.83

2.92

2.80

2.86

2.94

3.04

2.89

2.95

3.04

3.14

Amps

8.2

8.4

8.7

9.0

8.9

9.1

9.4

9.8

9.7

9.9

10.2

10.6

10.3

10.6

11.0

11.4

11.0

11.3

11.7

12.1

11.7

12.0

12.4

12.8

Hi P

R22

424

125

426

525

127

028

529

828

630

732

533

932

535

037

038

636

639

441

643

440

443

546

047

9Lo

PR

105

112

122

130

111

118

129

137

115

123

134

143

121

129

141

150

127

135

147

157

131

140

152

162

1200

MBh

34.3

35.0

37.4

40.0

33.5

34.2

36.5

39.1

32.7

33.4

35.7

38.1

31.9

32.6

34.8

37.2

30.3

30.9

33.1

35.3

28.1

28.7

30.6

32.7

S/T

0.95

0.89

0.72

0.54

0.98

0.92

0.75

0.56

1.00

0.95

0.77

0.57

1.00

0.98

0.79

0.59

1.00

1.00

0.82

0.62

1.00

1.00

0.83

0.62

∆T25

2421

1725

2421

1725

2421

1724

2421

1723

2421

1721

2219

16kW

2.32

2.36

2.43

2.50

2.48

2.53

2.61

2.69

2.63

2.68

2.76

2.85

2.76

2.81

2.90

2.99

2.87

2.93

3.02

3.11

2.96

3.02

3.12

3.22

Amps

8.4

8.7

8.9

9.3

9.1

9.4

9.7

10.0

9.9

10.2

10.5

10.9

10.6

10.9

11.3

11.7

11.3

11.6

12.0

12.5

12.0

12.3

12.7

13.2

Hi P

R23

124

826

227

425

927

929

430

729

531

733

534

933

536

138

139

837

740

642

944

741

744

947

449

4Lo

PR

108

115

126

134

114

122

133

141

119

126

138

147

125

133

145

154

131

139

152

162

135

144

157

167

1350

MBh

35.3

36.1

38.5

41.2

34.5

35.2

37.6

40.2

33.7

34.4

36.7

39.3

32.8

33.5

35.8

38.3

31.2

31.9

34.1

36.4

28.9

29.5

31.5

33.7

S/T

1.00

0.93

0.76

0.57

1.00

0.97

0.79

0.59

1.00

1.00

0.81

0.60

1.00

1.00

0.83

0.62

1.00

1.00

0.86

0.65

1.00

1.00

0.87

0.65

∆T24

2320

1623

2320

1623

2320

1622

2320

1621

2220

1620

2019

15kW

2.33

2.38

2.45

2.52

2.50

2.55

2.63

2.71

2.65

2.70

2.78

2.87

2.78

2.83

2.92

3.02

2.89

2.95

3.04

3.14

2.98

3.05

3.14

3.24

Amps

8.5

8.7

9.0

9.4

9.2

9.5

9.8

10.1

10.0

10.3

10.6

11.0

10.7

11.0

11.4

11.8

11.4

11.7

12.1

12.6

12.1

12.4

12.9

13.3

Hi P

R23

325

126

527

626

228

129

731

029

732

033

835

333

936

538

540

238

141

043

345

242

145

347

949

9Lo

PR

109

116

127

135

116

123

134

143

120

128

139

148

126

134

146

156

132

141

153

163

137

145

159

169

85

1050

MBh

32.2

32.8

34.4

36.7

31.4

32.0

33.6

35.8

30.7

31.3

32.8

34.9

29.9

30.5

32.0

34.1

28.4

29.0

30.4

32.4

26.3

26.9

28.1

30.0

S/T

0.96

0.92

0.83

0.68

0.99

0.96

0.87

0.70

1.00

0.98

0.89

0.72

1.00

1.00

0.92

0.74

1.00

1.00

0.95

0.77

1.00

1.00

0.96

0.78

∆T27

2725

2227

2725

2227

2725

2226

2726

2225

2525

2223

2424

20kW

2.28

2.33

2.39

2.46

2.44

2.49

2.57

2.64

2.59

2.64

2.72

2.80

2.71

2.77

2.85

2.94

2.82

2.88

2.97

3.06

2.91

2.97

3.07

3.17

Amps

8.3

8.5

8.8

9.1

9.0

9.2

9.5

9.9

9.8

10.0

10.3

10.7

10.4

10.7

11.1

11.5

11.1

11.4

11.8

12.2

11.8

12.1

12.5

13.0

Hi P

R22

624

325

726

825

427

328

830

128

931

132

834

232

935

437

339

037

039

842

043

840

944

046

448

4Lo

PR

106

113

123

131

112

119

130

139

116

124

135

144

122

130

142

151

128

136

149

159

133

141

154

164

1200

MBh

34.9

35.5

37.2

39.7

34.1

34.7

36.4

38.8

33.2

33.9

35.5

37.9

32.4

33.1

34.6

36.9

30.8

31.4

32.9

35.1

28.5

29.1

30.5

32.5

S/T

0.99

0.96

0.87

0.70

1.00

0.99

0.90

0.73

1.00

1.00

0.92

0.75

1.00

1.00

0.95

0.77

1.00

1.00

0.99

0.80

1.00

1.00

0.99

0.81

∆T27

2625

2126

2625

2225

2625

2225

2525

2224

2425

2122

2223

20kW

2.33

2.38

2.45

2.52

2.50

2.55

2.63

2.71

2.65

2.70

2.78

2.87

2.78

2.83

2.92

3.02

2.89

2.95

3.04

3.14

2.98

3.05

3.14

3.24

Amps

8.5

8.7

9.0

9.4

9.2

9.5

9.8

10.1

10.0

10.3

10.6

11.0

10.7

11.0

11.4

11.8

11.4

11.7

12.1

12.6

12.1

12.4

12.9

13.3

Hi P

R23

325

126

527

626

228

129

731

029

732

033

835

333

936

538

540

238

141

043

345

242

145

347

949

9Lo

PR

109

116

127

135

116

123

134

143

120

128

139

148

126

134

146

156

132

141

153

163

137

145

159

169

1350

MBh

35.9

36.6

38.3

40.9

35.1

35.8

37.4

40.0

34.2

34.9

36.6

39.0

33.4

34.1

35.7

38.0

31.7

32.4

33.9

36.1

29.4

30.0

31.4

33.5

S/T

1.00

1.00

0.91

0.74

1.00

1.00

0.94

0.76

1.00

1.00

0.96

0.78

1.00

1.00

1.00

0.81

1.00

1.00

1.00

0.84

1.00

1.00

1.00

0.85

∆T24

2524

2124

2424

2123

2424

2123

2324

2122

2223

2120

2021

19kW

2.35

2.40

2.47

2.54

2.52

2.57

2.65

2.73

2.67

2.72

2.81

2.89

2.80

2.86

2.95

3.04

2.91

2.97

3.07

3.16

3.01

3.07

3.17

3.27

Amps

8.6

8.8

9.1

9.4

9.3

9.5

9.9

10.2

10.1

10.4

10.7

11.1

10.8

11.1

11.5

11.9

11.5

11.8

12.2

12.7

12.2

12.5

13.0

13.5

Hi P

R23

525

326

827

926

428

430

031

330

032

334

135

634

236

838

940

638

541

443

745

642

545

848

350

4Lo

PR

110

117

128

137

117

124

135

144

121

129

141

150

127

135

148

158

133

142

155

165

138

147

160

171

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

14 www.daikincomfort.com SS-DX16SA

Expanded Cooling Data — DX16SA0371A* / CA*F4860*6D*+EEP+TXV

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

70

1050

MBh

36.6

37.1

38.2

-36

.336

.837

.9-

35.3

35.9

37.0

-33

.734

.235

.3-

31.7

32.2

33.3

-29

.830

.431

.5-

S/T

0.60

0.53

0.39

-0.

610.

530.

40-

0.63

0.56

0.42

-0.

650.

580.

44-

0.67

0.60

0.46

-1.

000.

650.

51-

∆T21

1915

-21

1915

-21

1916

-21

1915

-21

1915

-22

2016

-kW

2.10

2.10

2.10

-2.

342.

342.

34-

2.61

2.61

2.60

-2.

902.

892.

89-

3.22

3.21

3.21

-3.

593.

593.

59-

Amps

7.6

7.6

7.6

-8.

78.

78.

7-

9.9

9.9

9.9

-11

.211

.211

.2-

12.7

12.7

12.7

-14

.414

.414

.4-

Hi P

R24

524

624

8-

283

285

286

-32

432

532

7-

367

369

370

-41

441

641

7-

465

466

467

-Lo

PR

118

120

123

-12

612

713

0-

132

133

136

-13

713

914

2-

143

144

147

-14

915

115

4-

1200

MBh

37.1

37.6

38.7

-36

.837

.338

.4-

35.8

36.3

37.4

-34

.234

.735

.8-

32.2

32.7

33.8

-30

.330

.831

.9-

S/T

0.66

0.59

0.45

-0.

670.

590.

46-

0.69

0.62

0.48

-0.

710.

640.

50-

1.00

0.66

0.52

-1.

000.

710.

57-

∆T20

1814

-20

1814

-20

1814

-20

1814

-19

1714

-21

1915

-kW

2.12

2.11

2.11

-2.

352.

352.

35-

2.62

2.62

2.61

-2.

912.

912.

90-

3.23

3.23

3.22

-3.

613.

603.

60-

Amps

7.7

7.7

7.7

-8.

88.

88.

7-

10.0

10.0

10.0

-11

.311

.311

.3-

12.8

12.8

12.7

-14

.514

.514

.5-

Hi P

R24

724

825

0-

286

287

288

-32

632

732

9-

370

371

372

-41

741

841

9-

467

468

469

-Lo

PR

120

122

125

-12

712

913

2-

134

135

138

-13

914

014

3-

144

146

149

-15

115

215

5-

1350

MBh

37.7

38.2

39.3

-37

.437

.939

.0-

36.4

36.9

38.0

-34

.835

.336

.4-

32.7

33.3

34.4

-30

.931

.432

.5-

S/T

0.70

0.62

0.48

-0.

700.

630.

49-

0.73

0.65

0.52

-0.

750.

670.

54-

1.00

0.69

0.56

-1.

000.

740.

61-

∆T19

1713

-19

1713

-19

1713

-19

1713

-18

1613

-20

1814

-kW

2.13

2.12

2.12

-2.

362.

362.

36-

2.63

2.63

2.62

-2.

922.

922.

91-

3.24

3.24

3.23

-3.

623.

613.

61-

Amps

7.7

7.7

7.7

-8.

88.

88.

8-

10.0

10.0

10.0

-11

.411

.311

.3-

12.8

12.8

12.8

-14

.514

.514

.5-

Hi P

R24

925

025

2-

288

289

290

-32

832

933

1-

372

373

374

-41

942

042

1-

469

470

472

-Lo

PR

122

124

127

-12

913

113

4-

136

137

140

-14

114

214

5-

146

148

151

-15

315

415

7-

75

1050

MBh

36.6

37.2

38.3

39.9

36.3

36.8

37.9

39.6

35.4

35.9

37.0

38.6

33.7

34.2

35.3

37.0

31.7

32.2

33.3

35.0

29.9

30.4

31.5

33.2

S/T

0.73

0.65

0.52

0.38

0.74

0.66

0.53

0.38

0.76

0.69

0.55

0.41

1.00

0.70

0.57

0.43

1.00

0.73

0.59

0.45

1.00

0.78

0.64

0.50

∆T25

2320

1625

2320

1625

2320

1625

2320

1625

2319

1626

2420

17kW

2.10

2.10

2.10

2.11

2.34

2.34

2.33

2.35

2.61

2.60

2.60

2.62

2.89

2.89

2.89

2.91

3.22

3.21

3.21

3.23

3.59

3.59

3.59

3.60

Amps

7.6

7.6

7.6

7.7

8.7

8.7

8.7

8.8

9.9

9.9

9.9

10.0

11.2

11.2

11.2

11.3

12.7

12.7

12.7

12.8

14.4

14.4

14.4

14.5

Hi P

R24

524

624

825

228

428

528

629

132

432

532

733

136

836

937

037

541

541

641

742

246

546

646

847

2Lo

PR

118

120

123

128

126

127

130

135

132

133

136

141

137

139

142

147

143

144

147

152

149

151

154

159

1200

MBh

37.1

37.6

38.7

40.4

36.8

37.3

38.4

40.1

35.8

36.4

37.5

39.1

34.2

34.7

35.8

37.5

32.2

32.7

33.8

35.5

30.4

30.9

32.0

33.6

S/T

0.79

0.71

0.58

0.44

0.80

0.72

0.59

0.44

1.00

0.75

0.61

0.47

1.00

0.76

0.63

0.49

1.00

0.79

0.65

0.51

1.00

0.84

0.70

0.56

∆T24

2218

1524

2218

1524

2219

1524

2218

1524

2218

1425

2319

16kW

2.11

2.11

2.11

2.13

2.35

2.35

2.35

2.36

2.62

2.62

2.61

2.63

2.91

2.90

2.90

2.92

3.23

3.23

3.22

3.24

3.60

3.60

3.60

3.62

Amps

7.7

7.7

7.6

7.7

8.8

8.8

8.7

8.8

10.0

10.0

10.0

10.0

11.3

11.3

11.3

11.4

12.8

12.8

12.7

12.8

14.5

14.5

14.5

14.5

Hi P

R24

724

825

025

428

628

728

929

332

632

732

933

337

037

137

337

741

741

842

042

446

746

847

047

4Lo

PR

120

122

125

130

127

129

132

137

134

135

138

143

139

140

144

149

144

146

149

154

151

152

155

160

1350

MBh

37.7

38.2

39.3

41.0

37.4

37.9

39.0

40.7

36.4

36.9

38.0

39.7

34.8

35.3

36.4

38.1

32.8

33.3

34.4

36.0

30.9

31.4

32.5

34.2

S/T

0.82

0.75

0.61

0.47

0.83

0.75

0.62

0.48

1.00

0.78

0.64

0.50

1.00

0.80

0.66

0.52

1.00

0.82

0.69

0.54

1.00

0.87

0.74

0.59

∆T23

2117

1423

2117

1423

2118

1423

2117

1423

2117

1324

2218

15kW

2.12

2.12

2.12

2.14

2.36

2.36

2.36

2.38

2.63

2.63

2.62

2.64

2.92

2.91

2.91

2.93

3.24

3.24

3.23

3.25

3.61

3.61

3.61

3.63

Amps

7.7

7.7

7.7

7.8

8.8

8.8

8.8

8.9

10.0

10.0

10.0

10.1

11.3

11.3

11.3

11.4

12.8

12.8

12.8

12.9

14.5

14.5

14.5

14.6

Hi P

R24

925

025

225

628

828

929

129

532

832

933

133

537

237

337

537

941

942

042

242

646

947

047

247

6Lo

PR

122

124

127

132

129

131

134

139

136

137

140

145

141

142

145

150

146

148

151

156

153

154

157

162

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

SS-DX16SA www.daikincomfort.com 15

Expanded Cooling Data — DX16SA0371A* / CA*F4860*6D*+EEP+TXV (cont.)

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

80

1050

MBh

36.8

37.4

38.4

40.1

36.5

37.0

38.1

39.8

35.6

36.1

37.2

38.8

33.9

34.4

35.5

37.2

31.9

32.4

33.5

35.2

30.1

30.6

31.7

33.3

S/T

0.85

0.78

0.64

0.50

1.00

0.79

0.65

0.51

1.00

0.81

0.68

0.53

1.00

0.83

0.69

0.55

1.00

0.85

0.72

0.57

1.00

1.00

0.77

0.63

∆T29

2724

2029

2724

2030

2824

2029

2724

2029

2724

2030

2825

21kW

2.10

2.10

2.10

2.12

2.34

2.34

2.34

2.35

2.61

2.61

2.60

2.62

2.90

2.89

2.89

2.91

3.22

3.21

3.21

3.23

3.59

3.59

3.59

3.61

Amps

7.6

7.6

7.6

7.7

8.7

8.7

8.7

8.8

9.9

9.9

9.9

10.0

11.2

11.2

11.2

11.3

12.7

12.7

12.7

12.8

14.4

14.4

14.4

14.5

Hi P

R24

524

724

825

328

428

528

729

132

532

632

733

236

836

937

137

541

541

641

842

246

546

646

847

2Lo

PR

119

120

123

128

126

128

131

136

132

134

137

142

138

139

142

147

143

145

148

153

150

151

154

159

1200

MBh

37.3

37.8

38.9

40.6

37.0

37.5

38.6

40.3

36.0

36.6

37.6

39.3

34.4

34.9

36.0

37.7

32.4

32.9

34.0

35.7

30.5

31.1

32.2

33.8

S/T

0.91

0.84

0.70

0.56

1.00

0.84

0.71

0.57

1.00

0.87

0.73

0.59

1.00

0.89

0.75

0.61

1.00

1.00

0.78

0.63

1.00

1.00

0.83

0.69

∆T28

2623

1928

2623

1928

2723

1928

2623

1928

2622

1929

2724

20kW

2.12

2.11

2.11

2.13

2.35

2.35

2.35

2.37

2.62

2.62

2.61

2.63

2.91

2.91

2.90

2.92

3.23

3.23

3.22

3.24

3.61

3.60

3.60

3.62

Amps

7.7

7.7

7.7

7.7

8.8

8.8

8.7

8.8

10.0

10.0

10.0

10.0

11.3

11.3

11.3

11.4

12.8

12.8

12.7

12.8

14.5

14.5

14.5

14.6

Hi P

R24

824

925

025

528

628

728

929

332

732

832

933

437

037

137

337

741

741

842

042

446

746

847

047

4Lo

PR

121

122

125

130

128

129

132

137

134

136

139

144

140

141

144

149

145

146

149

154

151

153

156

161

1350

MBh

37.9

38.4

39.5

41.2

37.6

38.1

39.2

40.9

36.6

37.1

38.2

39.9

35.0

35.5

36.6

38.2

33.0

33.5

34.6

36.2

31.1

31.6

32.7

34.4

S/T

1.00

0.87

0.74

0.60

1.00

0.88

0.74

0.60

1.00

0.90

0.77

0.63

1.00

0.92

0.79

0.65

1.00

1.00

0.81

0.67

1.00

1.00

0.86

0.72

∆T27

2522

1827

2522

1827

2622

1827

2522

1827

2521

1828

2623

19kW

2.13

2.12

2.12

2.14

2.36

2.36

2.36

2.38

2.63

2.63

2.62

2.64

2.92

2.92

2.91

2.93

3.24

3.24

3.23

3.25

3.62

3.61

3.61

3.63

Amps

7.7

7.7

7.7

7.8

8.8

8.8

8.8

8.9

10.0

10.0

10.0

10.1

11.3

11.3

11.3

11.4

12.8

12.8

12.8

12.9

14.5

14.5

14.5

14.6

Hi P

R25

025

125

225

728

828

929

129

532

933

033

133

637

237

337

537

941

942

042

242

646

947

047

247

6Lo

PR

123

124

127

132

130

131

134

139

136

138

141

146

141

143

146

151

147

148

151

156

153

155

158

163

85

1050

MBh

37.5

38.0

39.1

40.7

37.1

37.6

38.7

40.4

36.2

36.7

37.8

39.5

34.5

35.0

36.1

37.8

32.5

33.0

34.1

35.8

30.7

31.2

32.3

34.0

S/T

1.00

0.88

0.74

0.60

1.00

0.89

0.75

0.61

1.00

1.00

0.78

0.63

1.00

1.00

0.80

0.65

1.00

1.00

0.82

0.68

1.00

1.00

0.87

0.73

∆T33

3128

2433

3128

2433

3228

2433

3128

2433

3127

2434

3229

25kW

2.11

2.11

2.10

2.12

2.35

2.34

2.34

2.36

2.61

2.61

2.61

2.62

2.90

2.90

2.89

2.91

3.22

3.22

3.22

3.23

3.60

3.60

3.59

3.61

Amps

7.6

7.6

7.6

7.7

8.7

8.7

8.7

8.8

9.9

9.9

9.9

10.0

11.3

11.3

11.2

11.3

12.7

12.7

12.7

12.8

14.5

14.5

14.4

14.5

Hi P

R24

724

824

925

428

528

628

829

232

632

732

933

336

937

037

237

641

641

741

942

346

646

846

947

3Lo

PR

121

122

125

130

128

129

132

137

134

136

139

144

140

141

144

149

145

146

149

154

151

153

156

161

1200

MBh

37.9

38.5

39.5

41.2

37.6

38.1

39.2

40.9

36.7

37.2

38.3

39.9

35.0

35.5

36.6

38.3

33.0

33.5

34.6

36.3

31.2

31.7

32.8

34.4

S/T

1.00

0.94

0.80

0.66

1.00

0.95

0.81

0.67

1.00

1.00

0.84

0.69

1.00

1.00

0.85

0.71

1.00

1.00

0.88

0.73

1.00

1.00

0.93

0.79

∆T32

3027

2332

3026

2332

3027

2332

3026

2332

3026

2233

3127

24kW

2.12

2.12

2.11

2.13

2.36

2.36

2.35

2.37

2.62

2.62

2.62

2.64

2.91

2.91

2.91

2.92

3.23

3.23

3.23

3.25

3.61

3.61

3.60

3.62

Amps

7.7

7.7

7.7

7.8

8.8

8.8

8.8

8.8

10.0

10.0

10.0

10.1

11.3

11.3

11.3

11.4

12.8

12.8

12.8

12.8

14.5

14.5

14.5

14.6

Hi P

R24

925

025

125

628

728

829

029

432

832

933

133

537

137

237

437

841

841

942

142

546

947

047

147

6Lo

PR

122

124

127

132

130

131

134

139

136

137

140

146

141

143

146

151

147

148

151

156

153

155

158

163

1350

MBh

38.5

39.0

40.1

41.8

38.2

38.7

39.8

41.5

37.2

37.7

38.8

40.5

35.6

36.1

37.2

38.9

33.6

34.1

35.2

36.9

31.7

32.3

33.3

35.0

S/T

1.00

0.97

0.84

0.70

1.00

0.98

0.84

0.70

1.00

1.00

0.87

0.73

1.00

1.00

0.89

0.75

1.00

1.00

0.91

0.77

1.00

1.00

1.00

0.82

∆T31

2926

2231

2925

2231

2926

2231

2925

2231

2925

2132

3026

23kW

2.13

2.13

2.12

2.14

2.37

2.37

2.36

2.38

2.63

2.63

2.63

2.65

2.92

2.92

2.92

2.93

3.24

3.24

3.24

3.26

3.62

3.62

3.61

3.63

Amps

7.7

7.7

7.7

7.8

8.8

8.8

8.8

8.9

10.1

10.0

10.0

10.1

11.4

11.4

11.3

11.4

12.8

12.8

12.8

12.9

14.6

14.6

14.5

14.6

Hi P

R25

125

225

425

828

929

029

229

633

033

133

333

737

337

437

638

042

042

142

342

747

147

247

347

8Lo

PR

124

126

129

134

132

133

136

141

138

139

142

147

143

145

148

153

149

150

153

158

155

157

160

165

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

16 www.daikincomfort.com SS-DX16SA

Expanded Cooling Data — DX16SA0421A* / CA*F4860*6D*+EEP+TXV

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

70

1225

MBh

36.9

38.2

41.9

-36

.037

.340

.9-

35.2

36.4

39.9

-34

.335

.639

.0-

32.6

33.8

37.0

-30

.231

.334

.3-

S/T

0.71

0.59

0.41

-0.

730.

610.

42-

0.75

0.63

0.43

-0.

780.

650.

45-

0.80

0.67

0.47

-0.

810.

680.

47-

∆T20

1713

-20

1713

-20

1713

-20

1713

-20

1713

-18

1612

-kW

2.70

2.76

2.83

-2.

892.

953.

03-

3.06

3.12

3.21

-3.

203.

273.

37-

3.33

3.39

3.50

-3.

433.

503.

61-

Amps

9.9

10.1

10.4

-10

.710

.911

.3-

11.6

11.8

12.2

-12

.312

.613

.1-

13.1

13.4

13.9

-13

.914

.214

.7-

Hi P

R21

923

624

9-

246

265

280

-28

030

131

8-

319

343

362

-35

938

640

8-

396

427

451

-Lo

PR

102

109

119

-10

811

512

6-

113

120

131

-11

812

613

7-

124

132

144

-12

813

614

9-

1400

MBh

40.0

41.4

45.4

-39

.040

.544

.3-

38.1

39.5

43.3

-37

.238

.542

.2-

35.3

36.6

40.1

-32

.733

.937

.1-

S/T

0.73

0.61

0.42

-0.

760.

630.

44-

0.78

0.65

0.45

-0.

800.

670.

47-

0.83

0.70

0.48

-0.

840.

700.

49-

∆T19

1713

-19

1713

-19

1713

-20

1713

-19

1713

-18

1612

-kW

2.76

2.82

2.90

-2.

963.

023.

10-

3.13

3.19

3.29

-3.

283.

343.

45-

3.40

3.48

3.58

-3.

513.

593.

70-

Amps

10.1

10.4

10.7

-10

.911

.211

.6-

11.9

12.2

12.6

-12

.713

.013

.4-

13.5

13.8

14.3

-14

.314

.615

.1-

Hi P

R22

624

325

7-

254

273

288

-28

931

132

8-

329

354

374

-37

039

842

0-

409

440

464

-Lo

PR

106

112

123

-11

211

913

0-

116

123

135

-12

213

014

2-

128

136

148

-13

214

115

3-

1575

MBh

41.2

42.7

46.7

-40

.241

.745

.7-

39.2

40.7

44.6

-38

.339

.743

.5-

36.4

37.7

41.3

-33

.734

.938

.3-

S/T

0.77

0.64

0.44

-0.

800.

670.

46-

0.82

0.68

0.47

-0.

840.

700.

49-

0.87

0.73

0.51

-0.

880.

740.

51-

∆T18

1612

-19

1612

-19

1612

-19

1612

-19

1612

-17

1511

-kW

2.78

2.84

2.92

-2.

983.

043.

13-

3.15

3.21

3.31

-3.

303.

373.

47-

3.43

3.50

3.61

-3.

543.

623.

73-

Amps

10.2

10.5

10.8

-11

.011

.311

.7-

12.0

12.3

12.7

-12

.813

.113

.6-

13.6

14.0

14.4

-14

.414

.815

.3-

Hi P

R22

824

626

0-

256

276

291

-29

231

433

1-

332

357

377

-37

440

242

5-

413

444

469

-Lo

PR

107

114

124

-11

312

013

1-

117

125

136

-12

313

114

3-

129

137

150

-13

314

215

5-

75

1225

MBh

37.5

38.6

41.8

44.9

36.6

37.7

40.8

43.8

35.8

36.8

39.9

42.8

34.9

35.9

38.9

41.7

33.1

34.1

36.9

39.6

30.7

31.6

34.2

36.7

S/T

0.80

0.72

0.54

0.35

0.83

0.74

0.56

0.36

0.85

0.76

0.58

0.37

0.88

0.79

0.60

0.38

0.91

0.82

0.62

0.40

0.92

0.82

0.62

0.40

∆T23

2117

1223

2117

1223

2117

1223

2117

1223

2117

1221

2016

11kW

2.72

2.78

2.86

2.94

2.91

2.97

3.06

3.15

3.08

3.14

3.23

3.33

3.23

3.29

3.39

3.50

3.35

3.42

3.53

3.64

3.46

3.53

3.64

3.76

Amps

10.0

10.2

10.5

10.9

10.8

11.0

11.4

11.8

11.7

11.9

12.3

12.8

12.5

12.8

13.2

13.7

13.3

13.6

14.0

14.6

14.0

14.4

14.9

15.4

Hi P

R22

223

925

226

324

926

828

329

528

330

432

133

532

234

736

638

236

339

041

243

040

143

145

547

5Lo

PR

104

110

120

128

109

116

127

135

114

121

132

141

119

127

139

148

125

133

145

155

129

138

150

160

1400

MBh

40.6

41.8

45.3

48.6

39.7

40.9

44.2

47.5

38.7

39.9

43.2

46.3

37.8

38.9

42.1

45.2

35.9

37.0

40.0

43.0

33.3

34.2

37.1

39.8

S/T

0.83

0.75

0.56

0.36

0.86

0.77

0.58

0.38

0.89

0.79

0.60

0.39

0.91

0.82

0.62

0.40

0.95

0.85

0.64

0.41

0.96

0.86

0.65

0.42

∆T22

2017

1223

2117

1223

2117

1223

2117

1222

2117

1221

1916

11kW

2.78

2.84

2.92

3.01

2.98

3.04

3.13

3.22

3.15

3.21

3.31

3.41

3.30

3.37

3.47

3.58

3.43

3.50

3.61

3.72

3.54

3.62

3.73

3.85

Amps

10.2

10.5

10.8

11.2

11.0

11.3

11.7

12.1

12.0

12.3

12.7

13.2

12.8

13.1

13.6

14.1

13.6

14.0

14.4

15.0

14.4

14.8

15.3

15.9

Hi P

R22

924

626

027

125

627

629

130

429

231

433

134

633

235

737

739

437

440

242

544

341

344

446

948

9Lo

PR

107

114

124

132

113

120

131

139

117

125

136

145

123

131

143

152

129

137

150

160

133

142

155

165

1575

MBh

41.9

43.1

46.6

50.1

40.9

42.1

45.6

48.9

39.9

41.1

44.5

47.7

38.9

40.1

43.4

46.6

37.0

38.1

41.2

44.2

34.3

35.3

38.2

41.0

S/T

0.87

0.78

0.59

0.38

0.91

0.81

0.61

0.39

0.93

0.83

0.63

0.40

0.96

0.86

0.65

0.42

0.99

0.89

0.67

0.43

1.00

0.90

0.68

0.44

∆T21

2016

1122

2016

1122

2016

1122

2016

1121

2016

1120

1815

10kW

2.80

2.86

2.94

3.03

3.00

3.06

3.15

3.25

3.17

3.24

3.34

3.44

3.33

3.40

3.50

3.61

3.46

3.53

3.64

3.75

3.57

3.65

3.76

3.88

Amps

10.3

10.6

10.9

11.3

11.1

11.4

11.8

12.2

12.1

12.4

12.8

13.3

12.9

13.2

13.7

14.2

13.8

14.1

14.6

15.1

14.6

14.9

15.4

16.0

Hi P

R23

124

826

227

425

927

929

430

729

531

733

534

933

636

138

139

837

740

642

944

741

744

947

449

4Lo

PR

108

115

125

133

114

121

132

141

118

126

137

146

124

132

144

154

130

139

151

161

135

143

157

167

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

SS-DX16SA www.daikincomfort.com 17

Expanded Cooling Data — DX16SA0421A* / CA*F4860*6D*+EEP+TXV (cont.)

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

80

1225

MBh

38.2

39.0

41.7

44.5

37.3

38.1

40.7

43.5

36.4

37.2

39.7

42.5

35.5

36.3

38.8

41.4

33.7

34.5

36.8

39.4

31.2

31.9

34.1

36.5

S/T

0.88

0.83

0.67

0.50

0.91

0.86

0.70

0.52

0.94

0.88

0.71

0.53

0.97

0.91

0.74

0.55

1.00

0.94

0.77

0.57

1.01

0.95

0.77

0.58

∆T25

2421

1726

2421

1726

2521

1726

2521

1725

2421

1724

2320

16kW

2.74

2.80

2.88

2.96

2.93

2.99

3.08

3.17

3.10

3.17

3.26

3.36

3.25

3.32

3.42

3.52

3.38

3.45

3.55

3.66

3.49

3.56

3.67

3.79

Amps

10.0

10.3

10.6

11.0

10.8

11.1

11.5

11.9

11.8

12.1

12.5

12.9

12.6

12.9

13.3

13.8

13.4

13.7

14.2

14.7

14.2

14.5

15.0

15.6

Hi P

R22

424

125

426

525

127

028

629

828

630

832

533

932

535

037

038

636

639

441

643

440

543

546

048

0Lo

PR

105

111

121

129

110

118

128

137

115

122

133

142

121

128

140

149

126

134

147

156

131

139

152

162

1400

MBh

41.4

42.3

45.2

48.3

40.4

41.3

44.1

47.1

39.4

40.3

43.1

46.0

38.5

39.3

42.0

44.9

36.5

37.3

39.9

42.7

33.9

34.6

37.0

39.5

S/T

0.91

0.86

0.70

0.52

0.95

0.89

0.72

0.54

0.97

0.91

0.74

0.55

1.00

0.94

0.77

0.57

1.00

0.98

0.79

0.59

1.00

0.98

0.80

0.60

∆T25

2421

1725

2421

1725

2421

1725

2421

1724

2421

1722

2219

16kW

2.80

2.86

2.94

3.03

3.00

3.06

3.15

3.25

3.18

3.24

3.34

3.44

3.33

3.40

3.50

3.61

3.46

3.53

3.64

3.75

3.57

3.65

3.76

3.88

Amps

10.3

10.6

10.9

11.3

11.1

11.4

11.8

12.2

12.1

12.4

12.8

13.3

12.9

13.2

13.7

14.2

13.8

14.1

14.6

15.1

14.6

14.9

15.4

16.0

Hi P

R23

124

826

227

425

927

929

430

729

531

733

534

933

636

138

139

837

740

642

944

741

744

947

449

4Lo

PR

108

115

125

133

114

121

132

141

118

126

137

146

124

132

144

154

130

139

151

161

135

143

157

167

1575

MBh

42.6

43.5

46.5

49.7

41.6

42.5

45.4

48.6

40.6

41.5

44.3

47.4

39.6

40.5

43.3

46.2

37.6

38.5

41.1

43.9

34.9

35.6

38.1

40.7

S/T

0.96

0.90

0.73

0.55

1.00

0.93

0.76

0.57

1.00

0.95

0.78

0.58

1.00

1.00

0.80

0.60

1.00

1.00

0.83

0.62

1.00

1.00

0.84

0.63

∆T24

2320

1624

2320

1624

2320

1623

2420

1622

2220

1620

2119

15kW

2.82

2.88

2.96

3.05

3.02

3.08

3.17

3.27

3.20

3.26

3.36

3.47

3.35

3.42

3.53

3.64

3.49

3.56

3.67

3.78

3.60

3.67

3.79

3.91

Amps

10.4

10.7

11.0

11.4

11.2

11.5

11.9

12.3

12.2

12.5

12.9

13.4

13.0

13.4

13.8

14.3

13.9

14.2

14.7

15.2

14.7

15.1

15.6

16.2

Hi P

R23

325

126

527

626

228

229

731

029

832

033

835

333

936

538

540

238

141

043

345

242

145

347

949

9Lo

PR

109

116

126

135

115

122

134

142

120

127

139

148

126

134

146

155

132

140

153

163

136

145

158

168

85

1225

MBh

38.8

39.6

41.5

44.2

37.9

38.7

40.5

43.2

37.0

37.7

39.5

42.2

36.1

36.8

38.6

41.2

34.3

35.0

36.6

39.1

31.8

32.4

33.9

36.2

S/T

0.92

0.89

0.80

0.65

0.96

0.92

0.83

0.68

0.98

0.95

0.85

0.69

1.00

0.98

0.88

0.72

1.00

1.00

0.92

0.74

1.00

1.00

0.92

0.75

∆T27

2625

2227

2725

2227

2725

2227

2726

2226

2625

2224

2424

20kW

2.76

2.82

2.90

2.98

2.96

3.01

3.10

3.20

3.13

3.19

3.28

3.38

3.28

3.34

3.44

3.55

3.40

3.47

3.58

3.69

3.51

3.59

3.70

3.82

Amps

10.1

10.4

10.7

11.1

10.9

11.2

11.6

12.0

11.9

12.2

12.6

13.0

12.7

13.0

13.4

13.9

13.5

13.8

14.3

14.8

14.3

14.6

15.1

15.7

Hi P

R22

624

325

726

825

427

328

830

128

931

132

834

232

935

437

439

037

039

842

043

840

944

046

448

4Lo

PR

106

112

123

131

112

119

130

138

116

123

135

143

122

130

141

151

128

136

148

158

132

140

153

163

1400

MBh

42.1

42.9

44.9

47.9

41.1

41.9

43.9

46.8

40.1

40.9

42.8

45.7

39.1

39.9

41.8

44.6

37.2

37.9

39.7

42.4

34.4

35.1

36.8

39.2

S/T

0.96

0.92

0.83

0.68

0.99

0.96

0.86

0.70

1.00

0.98

0.89

0.72

1.00

1.00

0.91

0.74

1.00

1.00

0.95

0.77

1.00

1.00

0.96

0.78

∆T26

2625

2127

2625

2226

2625

2226

2625

2224

2525

2123

2323

20kW

2.82

2.88

2.96

3.05

3.02

3.08

3.17

3.27

3.20

3.26

3.36

3.47

3.35

3.42

3.53

3.64

3.49

3.56

3.67

3.78

3.60

3.67

3.79

3.91

Amps

10.4

10.7

11.0

11.4

11.2

11.5

11.9

12.3

12.2

12.5

12.9

13.4

13.0

13.4

13.8

14.3

13.9

14.2

14.7

15.2

14.7

15.1

15.6

16.2

Hi P

R23

325

126

527

626

228

229

731

029

832

033

835

333

936

538

540

238

141

043

345

242

145

347

949

9Lo

PR

109

116

126

135

115

122

134

142

120

127

139

148

126

134

146

155

132

140

153

163

136

145

158

168

1575

MBh

43.3

44.2

46.3

49.4

42.3

43.2

45.2

48.2

41.3

42.1

44.1

47.1

40.3

41.1

43.0

45.9

38.3

39.0

40.9

43.6

35.5

36.2

37.9

40.4

S/T

1.00

0.97

0.87

0.71

1.00

1.00

0.91

0.74

1.00

1.00

0.93

0.75

1.00

1.00

0.96

0.78

1.00

1.00

1.00

0.81

1.00

1.00

1.00

0.81

∆T25

2524

2025

2524

2124

2524

2124

2424

2122

2324

2121

2122

19kW

2.85

2.90

2.98

3.07

3.05

3.11

3.20

3.30

3.22

3.29

3.39

3.49

3.38

3.45

3.55

3.67

3.51

3.59

3.70

3.81

3.63

3.70

3.82

3.94

Amps

10.5

10.8

11.1

11.5

11.3

11.6

12.0

12.4

12.3

12.6

13.0

13.5

13.2

13.5

13.9

14.5

14.0

14.3

14.8

15.4

14.8

15.2

15.7

16.3

Hi P

R23

525

326

827

926

428

430

031

330

132

334

235

634

236

838

940

638

541

443

845

642

545

848

350

4Lo

PR

110

117

128

136

116

124

135

144

121

128

140

149

127

135

147

157

133

141

154

164

137

146

160

170

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

18 www.daikincomfort.com SS-DX16SA

Expanded Cooling Data — DX16SA0481A* / CA*F4961*6D*+EEP+TXV

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

70

1400

MBh

42.6

44.2

48.4

-41

.643

.247

.3-

40.7

42.1

46.2

-39

.741

.145

.0-

37.7

39.1

42.8

-34

.936

.239

.6-

S/T

0.70

0.58

0.40

-0.

720.

600.

42-

0.74

0.62

0.43

-0.

770.

640.

44-

0.79

0.66

0.46

-0.

800.

670.

46-

∆T20

1713

-20

1713

-20

1713

-20

1713

-20

1713

-18

1612

-kW

2.95

3.01

3.10

-3.

163.

223.

32-

3.34

3.41

3.51

-3.

503.

573.

68-

3.64

3.71

3.83

-3.

763.

843.

95-

Amps

10.8

11.0

11.4

-11

.611

.912

.3-

12.6

12.9

13.4

-13

.513

.814

.3-

14.4

14.7

15.2

-15

.215

.616

.1-

Hi P

R21

923

524

8-

245

264

279

-27

930

031

7-

318

342

361

-35

738

540

6-

395

425

449

-Lo

PR

106

113

123

-11

211

913

0-

116

124

135

-12

213

014

2-

128

136

149

-13

214

115

4-

1500

MBh

43.3

44.9

49.2

-42

.343

.848

.0-

41.3

42.8

46.9

-40

.341

.745

.7-

38.3

39.6

43.4

-35

.436

.740

.2-

S/T

0.72

0.60

0.42

-0.

750.

630.

43-

0.77

0.64

0.44

-0.

790.

660.

46-

0.82

0.69

0.48

-0.

830.

690.

48-

∆T19

1713

-19

1713

-19

1713

-20

1713

-19

1713

-18

1612

-kW

2.99

3.05

3.14

-3.

203.

263.

36-

3.39

3.45

3.56

-3.

553.

623.

73-

3.69

3.76

3.88

-3.

813.

894.

01-

Amps

10.9

11.2

11.6

-11

.812

.112

.5-

12.8

13.1

13.6

-13

.714

.114

.5-

14.6

15.0

15.5

-15

.515

.816

.4-

Hi P

R22

223

925

3-

250

269

284

-28

430

532

2-

323

348

367

-36

439

141

3-

402

432

457

-Lo

PR

108

115

125

-11

412

113

2-

118

126

137

-12

413

214

4-

130

139

151

-13

514

315

6-

1800

MBh

44.8

46.4

50.9

-43

.845

.449

.7-

42.7

44.3

48.5

-41

.743

.247

.3-

39.6

41.0

45.0

-36

.738

.041

.6-

S/T

0.77

0.64

0.44

-0.

800.

670.

46-

0.82

0.68

0.47

-0.

840.

700.

49-

0.88

0.73

0.51

-0.

880.

740.

51-

∆T18

1512

-18

1512

-18

1512

-18

1612

-18

1512

-17

1411

-kW

3.03

3.09

3.18

-3.

253.

313.

41-

3.44

3.51

3.61

-3.

603.

683.

79-

3.75

3.82

3.94

-3.

873.

954.

07-

Amps

11.1

11.4

11.8

-12

.012

.312

.7-

13.1

13.4

13.8

-14

.014

.314

.8-

14.9

15.2

15.7

-15

.816

.116

.7-

Hi P

R22

724

425

8-

255

274

289

-28

931

232

9-

330

355

375

-37

139

942

1-

410

441

466

-Lo

PR

110

117

128

-11

612

413

5-

121

128

140

-12

713

514

7-

133

141

154

-13

714

616

0-

75

1400

MBh

43.4

44.6

48.3

51.9

42.4

43.6

47.2

50.7

41.3

42.6

46.1

49.5

40.3

41.5

45.0

48.2

38.3

39.5

42.7

45.8

35.5

36.5

39.6

42.5

S/T

0.79

0.71

0.54

0.35

0.82

0.73

0.56

0.36

0.84

0.75

0.57

0.37

0.87

0.78

0.59

0.38

0.90

0.81

0.61

0.39

0.91

0.81

0.62

0.40

∆T23

2117

1223

2117

1223

2117

1223

2117

1223

2117

1221

2016

11kW

2.97

3.03

3.12

3.21

3.18

3.25

3.34

3.44

3.37

3.44

3.54

3.65

3.53

3.60

3.71

3.83

3.67

3.74

3.86

3.98

3.79

3.87

3.99

4.11

Amps

10.9

11.1

11.5

11.9

11.7

12.0

12.4

12.9

12.8

13.1

13.5

14.0

13.6

14.0

14.4

15.0

14.5

14.9

15.4

15.9

15.4

15.7

16.3

16.9

Hi P

R22

123

825

126

224

826

728

229

428

230

332

033

432

134

536

538

036

138

941

042

839

942

945

347

3Lo

PR

107

114

124

132

113

120

131

140

117

125

136

145

123

131

143

153

129

138

150

160

134

142

155

165

1500

MBh

44.0

45.3

49.1

52.7

43.0

44.3

47.9

51.4

42.0

43.2

46.8

50.2

41.0

42.2

45.6

49.0

38.9

40.1

43.4

46.5

36.0

37.1

40.2

43.1

S/T

0.82

0.74

0.56

0.36

0.85

0.76

0.58

0.37

0.87

0.78

0.59

0.38

0.90

0.81

0.61

0.39

0.94

0.84

0.63

0.41

0.94

0.84

0.64

0.41

∆T22

2017

1222

2117

1222

2117

1223

2117

1222

2117

1221

1916

11kW

3.01

3.07

3.16

3.25

3.22

3.29

3.39

3.49

3.41

3.48

3.59

3.70

3.58

3.65

3.76

3.88

3.72

3.79

3.91

4.04

3.84

3.92

4.04

4.17

Amps

11.0

11.3

11.7

12.1

11.9

12.2

12.6

13.1

13.0

13.3

13.7

14.2

13.8

14.2

14.7

15.2

14.7

15.1

15.6

16.2

15.6

16.0

16.5

17.2

Hi P

R22

524

225

526

625

227

128

629

928

730

932

634

032

735

137

138

736

739

541

743

540

643

746

148

1Lo

PR

109

116

126

135

115

122

134

142

120

127

139

148

126

134

146

155

132

140

153

163

136

145

158

168

1800

MBh

45.6

46.9

50.8

54.5

44.5

45.8

49.6

53.2

43.4

44.7

48.4

52.0

42.4

43.6

47.2

50.7

40.3

41.5

44.9

48.2

37.3

38.4

41.6

44.6

S/T

0.87

0.78

0.59

0.38

0.91

0.81

0.61

0.39

0.93

0.83

0.63

0.40

0.96

0.86

0.65

0.42

0.99

0.89

0.67

0.43

1.00

0.90

0.68

0.44

∆T20

1915

1121

1916

1121

1916

1121

1916

1120

1915

1119

1814

10kW

3.06

3.12

3.21

3.30

3.27

3.34

3.44

3.54

3.46

3.53

3.64

3.75

3.63

3.71

3.82

3.94

3.78

3.85

3.97

4.10

3.90

3.98

4.11

4.24

Amps

11.2

11.5

11.9

12.3

12.1

12.4

12.8

13.3

13.2

13.5

14.0

14.5

14.1

14.4

14.9

15.5

15.0

15.4

15.9

16.5

15.9

16.3

16.8

17.5

Hi P

R22

924

726

027

225

727

729

230

529

231

533

234

733

335

837

839

537

540

342

644

441

444

647

049

1Lo

PR

111

118

129

137

117

125

136

145

122

130

142

151

128

136

149

158

134

143

156

166

139

148

161

172

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

SS-DX16SA www.daikincomfort.com 19

Expanded Cooling Data — DX16SA0481A* / CA*F4961*6D*+EEP+TXV (cont.)

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

80

1400

MBh

44.1

45.1

48.2

51.5

43.1

44.0

47.1

50.3

42.1

43.0

45.9

49.1

41.1

41.9

44.8

47.9

39.0

39.9

42.6

45.5

36.1

36.9

39.4

42.2

S/T

0.87

0.82

0.66

0.50

0.90

0.85

0.69

0.51

0.92

0.87

0.71

0.53

0.95

0.89

0.73

0.54

0.99

0.93

0.76

0.56

1.00

0.94

0.76

0.57

∆T25

2421

1726

2421

1726

2421

1726

2521

1725

2421

1724

2320

16kW

3.00

3.05

3.14

3.24

3.21

3.27

3.37

3.47

3.39

3.46

3.57

3.68

3.56

3.63

3.74

3.86

3.70

3.77

3.89

4.01

3.82

3.90

4.02

4.15

Amps

11.0

11.2

11.6

12.0

11.9

12.1

12.5

13.0

12.9

13.2

13.6

14.1

13.8

14.1

14.6

15.1

14.6

15.0

15.5

16.1

15.5

15.9

16.4

17.1

Hi P

R22

324

025

326

425

026

928

429

728

530

632

333

732

434

936

838

436

539

341

443

240

343

445

847

8Lo

PR

108

115

126

134

114

121

133

141

119

126

138

147

125

133

145

154

131

139

152

162

135

144

157

167

1500

MBh

44.8

45.8

48.9

52.3

43.8

44.7

47.8

51.1

42.7

43.7

46.6

49.9

41.7

42.6

45.5

48.6

39.6

40.5

43.2

46.2

36.7

37.5

40.0

42.8

S/T

0.90

0.85

0.69

0.51

0.93

0.88

0.71

0.53

0.96

0.90

0.73

0.55

0.99

0.93

0.76

0.56

1.00

0.96

0.78

0.59

1.00

0.97

0.79

0.59

∆T25

2421

1625

2421

1725

2421

1725

2421

1724

2421

1722

2219

15kW

3.03

3.09

3.18

3.28

3.25

3.31

3.41

3.52

3.44

3.51

3.61

3.73

3.60

3.68

3.79

3.91

3.75

3.82

3.94

4.07

3.87

3.95

4.07

4.20

Amps

11.1

11.4

11.8

12.2

12.0

12.3

12.7

13.2

13.1

13.4

13.8

14.4

14.0

14.3

14.8

15.4

14.9

15.2

15.8

16.3

15.8

16.1

16.7

17.3

Hi P

R22

724

425

826

925

527

428

930

229

031

232

934

333

035

537

539

137

139

942

244

041

044

146

648

6Lo

PR

110

117

128

136

116

124

135

144

121

128

140

149

127

135

147

157

133

141

154

164

137

146

160

170

1800

MBh

46.4

47.4

50.6

54.1

45.3

46.3

49.4

52.9

44.2

45.2

48.3

51.6

43.1

44.1

47.1

50.3

41.0

41.9

44.7

47.8

38.0

38.8

41.4

44.3

S/T

0.96

0.90

0.73

0.55

1.00

0.93

0.76

0.57

1.00

0.96

0.78

0.58

1.00

1.00

0.80

0.60

1.00

1.00

0.83

0.62

1.00

1.00

0.84

0.63

∆T23

2219

1523

2219

1523

2219

1522

2319

1521

2119

1519

2018

14kW

3.08

3.14

3.23

3.33

3.30

3.36

3.46

3.57

3.49

3.56

3.67

3.78

3.66

3.74

3.85

3.97

3.80

3.88

4.01

4.13

3.93

4.01

4.14

4.27

Amps

11.3

11.6

12.0

12.4

12.3

12.6

13.0

13.4

13.3

13.6

14.1

14.6

14.2

14.6

15.1

15.6

15.1

15.5

16.0

16.7

16.1

16.4

17.0

17.7

Hi P

R23

124

926

327

426

027

929

530

829

531

833

635

033

636

238

239

937

840

743

044

941

845

047

549

6Lo

PR

112

119

130

139

118

126

138

147

123

131

143

152

129

138

150

160

136

144

157

168

140

149

163

173

85

1400

MBh

44.9

45.8

47.9

51.1

43.9

44.7

46.8

50.0

42.8

43.6

45.7

48.8

41.8

42.6

44.6

47.6

39.7

40.4

42.4

45.2

36.8

37.5

39.2

41.9

S/T

0.91

0.88

0.79

0.64

0.94

0.91

0.82

0.67

0.97

0.93

0.84

0.68

1.00

0.96

0.87

0.71

1.00

1.00

0.90

0.73

1.00

1.00

0.91

0.74

∆T27

2625

2227

2725

2227

2725

2227

2726

2226

2725

2224

2523

20kW

3.02

3.08

3.17

3.26

3.23

3.30

3.39

3.50

3.42

3.49

3.59

3.70

3.58

3.66

3.77

3.89

3.73

3.80

3.92

4.04

3.85

3.93

4.05

4.18

Amps

11.1

11.3

11.7

12.1

12.0

12.2

12.7

13.1

13.0

13.3

13.7

14.3

13.9

14.2

14.7

15.3

14.8

15.1

15.6

16.2

15.7

16.0

16.6

17.2

Hi P

R22

524

225

626

725

327

228

730

028

830

932

734

132

735

237

238

836

839

641

943

740

743

846

348

2Lo

PR

109

116

127

135

115

123

134

143

120

128

139

148

126

134

146

156

132

140

153

163

136

145

159

169

1500

MBh

45.6

46.5

48.7

51.9

44.5

45.4

47.5

50.7

43.5

44.3

46.4

49.5

42.4

43.2

45.3

48.3

40.3

41.1

43.0

45.9

37.3

38.0

39.8

42.5

S/T

0.95

0.91

0.82

0.67

0.98

0.95

0.85

0.69

1.00

0.97

0.87

0.71

1.00

1.00

0.90

0.73

1.00

1.00

0.94

0.76

1.00

1.00

0.95

0.77

∆T26

2625

2127

2625

2227

2625

2226

2625

2225

2525

2123

2323

20kW

3.06

3.12

3.21

3.30

3.27

3.34

3.44

3.54

3.46

3.53

3.64

3.75

3.63

3.71

3.82

3.94

3.78

3.85

3.97

4.10

3.90

3.98

4.11

4.24

Amps

11.2

11.5

11.9

12.3

12.1

12.4

12.8

13.3

13.2

13.5

14.0

14.5

14.1

14.4

14.9

15.5

15.0

15.4

15.9

16.5

15.9

16.3

16.8

17.5

Hi P

R22

924

726

027

225

727

729

230

529

231

533

234

733

335

837

939

537

540

342

644

441

444

647

149

1Lo

PR

111

118

129

137

117

125

136

145

122

130

142

151

128

136

149

158

134

143

156

166

139

148

161

172

1800

MBh

47.2

48.1

50.4

53.7

46.1

47.0

49.2

52.5

45.0

45.9

48.0

51.2

43.9

44.7

46.9

50.0

41.7

42.5

44.5

47.5

38.6

39.4

41.2

44.0

S/T

1.00

0.97

0.87

0.71

1.00

1.00

0.91

0.74

1.00

1.00

0.93

0.75

1.00

1.00

0.96

0.78

1.00

1.00

1.00

0.81

1.00

1.00

1.00

0.81

∆T24

2423

1924

2423

2023

2323

2022

2323

2021

2223

2020

2021

18kW

3.10

3.16

3.25

3.35

3.32

3.39

3.49

3.60

3.52

3.59

3.70

3.81

3.69

3.77

3.88

4.00

3.83

3.92

4.04

4.17

3.96

4.04

4.17

4.31

Amps

11.4

11.7

12.1

12.5

12.4

12.7

13.1

13.6

13.4

13.8

14.2

14.8

14.4

14.7

15.2

15.8

15.3

15.7

16.2

16.8

16.2

16.6

17.2

17.8

Hi P

R23

425

226

627

726

228

229

831

129

832

133

935

434

036

638

640

338

241

143

445

342

245

548

050

1Lo

PR

113

121

132

140

120

127

139

148

124

132

144

154

131

139

152

162

137

146

159

169

142

151

164

175

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

20 www.daikincomfort.com SS-DX16SA

Expanded Cooling Data — DX16SA0601A* / CA*F4961*6D*+EEP+TXV

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

70

1750

MBh

51.4

53.2

58.3

-50

.252

.057

.0-

49.0

50.8

55.6

-47

.849

.554

.3-

45.4

47.1

51.6

-42

.143

.647

.8-

S/T

0.73

0.61

0.42

-0.

760.

640.

44-

0.78

0.65

0.45

-0.

800.

670.

47-

0.84

0.70

0.48

-0.

840.

700.

49-

∆T20

1713

-20

1713

-20

1713

-20

1713

-20

1713

-19

1612

-kW

3.42

3.48

3.58

-3.

653.

723.

83-

3.86

3.94

4.06

-4.

054.

134.

25-

4.20

4.29

4.42

-4.

344.

434.

56-

Amps

12.6

12.9

13.3

-13

.613

.914

.4-

14.8

15.1

15.6

-15

.816

.116

.7-

16.7

17.2

17.7

-17

.718

.218

.8-

Hi P

R21

623

324

6-

243

261

276

-27

629

731

3-

314

338

357

-35

338

040

2-

391

420

444

-Lo

PR

103

109

119

-10

911

512

6-

113

120

131

-11

812

613

8-

124

132

144

-12

813

714

9-

1625

MBh

51.4

53.2

58.3

-50

.252

.057

.0-

49.0

50.8

55.6

-47

.849

.554

.3-

45.4

47.1

51.6

-42

.143

.647

.8-

S/T

0.73

0.61

0.42

-0.

760.

640.

44-

0.78

0.65

0.45

-0.

800.

670.

47-

0.84

0.70

0.48

-0.

840.

700.

49-

∆T21

1814

-21

1814

-21

1814

-21

1814

-21

1814

-19

1713

-kW

3.42

3.48

3.58

-3.

653.

723.

83-

3.86

3.94

4.06

-4.

054.

134.

25-

4.20

4.29

4.42

-4.

344.

434.

56-

Amps

12.6

12.9

13.3

-13

.613

.914

.4-

14.8

15.1

15.6

-15

.816

.116

.7-

16.7

17.2

17.7

-17

.718

.218

.8-

Hi P

R21

623

324

6-

243

261

276

-27

629

731

3-

314

338

357

-35

338

040

2-

391

420

444

-Lo

PR

103

109

119

-10

911

512

6-

113

120

131

-11

812

613

8-

124

132

144

-12

813

714

9-

2250

MBh

53.2

55.1

60.4

-51

.953

.859

.0-

50.7

52.5

57.6

-49

.551

.356

.2-

47.0

48.7

53.4

-43

.545

.149

.4-

S/T

0.78

0.65

0.45

-0.

810.

670.

47-

0.83

0.69

0.48

-0.

860.

710.

49-

0.89

0.74

0.51

-0.

900.

750.

52-

∆T17

1511

-17

1511

-17

1511

-17

1511

-17

1511

-16

1410

-kW

3.47

3.53

3.63

-3.

713.

783.

89-

3.92

4.00

4.12

-4.

114.

194.

32-

4.27

4.36

4.49

-4.

414.

504.

64-

Amps

12.8

13.1

13.6

-13

.914

.214

.6-

15.0

15.4

15.9

-16

.016

.417

.0-

17.1

17.5

18.0

-18

.118

.519

.1-

Hi P

R22

023

725

1-

247

266

281

-28

130

332

0-

320

345

364

-36

138

841

0-

398

429

453

-Lo

PR

105

111

122

-11

111

812

9-

115

122

134

-12

112

914

0-

127

135

147

-13

113

915

2-

75

1750

MBh

52.2

53.8

58.2

62.5

51.0

52.5

56.9

61.0

49.8

51.3

55.5

59.6

48.6

50.0

54.2

58.1

46.2

47.5

51.5

55.2

42.8

44.0

47.7

51.2

S/T

0.83

0.75

0.56

0.36

0.86

0.77

0.59

0.38

0.89

0.79

0.60

0.39

0.91

0.82

0.62

0.40

0.95

0.85

0.64

0.41

0.96

0.86

0.65

0.42

∆T23

2117

1223

2117

1223

2118

1223

2218

1223

2117

1222

2016

11kW

3.44

3.51

3.61

3.71

3.68

3.75

3.86

3.98

3.89

3.97

4.09

4.21

4.08

4.16

4.29

4.42

4.24

4.32

4.46

4.59

4.37

4.46

4.60

4.75

Amps

12.7

13.0

13.4

13.9

13.7

14.1

14.5

15.0

14.9

15.3

15.7

16.3

15.9

16.3

16.8

17.4

16.9

17.3

17.9

18.6

17.9

18.3

18.9

19.6

Hi P

R21

823

524

825

924

526

427

829

027

930

031

733

031

734

236

137

635

738

440

642

339

542

544

846

8Lo

PR

104

110

121

128

110

117

127

136

114

121

132

141

120

127

139

148

125

133

146

155

130

138

151

160

1625

MBh

52.2

53.8

58.2

62.5

51.0

52.5

56.9

61.0

49.8

51.3

55.5

59.6

48.6

50.0

54.2

58.1

46.2

47.5

51.5

55.2

42.8

44.0

47.7

51.2

S/T

0.83

0.75

0.56

0.36

0.86

0.77

0.59

0.38

0.89

0.79

0.60

0.39

0.91

0.82

0.62

0.40

0.95

0.85

0.64

0.41

0.96

0.86

0.65

0.42

∆T24

2218

1224

2218

1324

2218

1324

2218

1324

2218

1322

2117

12kW

3.44

3.51

3.61

3.71

3.68

3.75

3.86

3.98

3.89

3.97

4.09

4.21

4.08

4.16

4.29

4.42

4.24

4.32

4.46

4.59

4.37

4.46

4.60

4.75

Amps

12.7

13.0

13.4

13.9

13.7

14.1

14.5

15.0

14.9

15.3

15.7

16.3

15.9

16.3

16.8

17.4

16.9

17.3

17.9

18.6

17.9

18.3

18.9

19.6

Hi P

R21

823

524

825

924

526

427

829

027

930

031

733

031

734

236

137

635

738

440

642

339

542

544

846

8Lo

PR

104

110

121

128

110

117

127

136

114

121

132

141

120

127

139

148

125

133

146

155

130

138

151

160

2250

MBh

54.1

55.7

60.3

64.7

52.8

54.4

58.9

63.2

51.6

53.1

57.5

61.7

50.3

51.8

56.1

60.2

47.8

49.2

53.3

57.2

44.3

45.6

49.3

52.9

S/T

0.89

0.79

0.60

0.39

0.92

0.82

0.62

0.40

0.94

0.84

0.64

0.41

0.97

0.87

0.66

0.42

1.00

0.90

0.68

0.44

1.00

0.91

0.69

0.44

∆T20

1815

1020

1815

1020

1815

1020

1815

1020

1815

1018

1714

10kW

3.49

3.56

3.66

3.77

3.73

3.81

3.92

4.04

3.95

4.03

4.15

4.28

4.14

4.22

4.35

4.49

4.30

4.39

4.53

4.67

4.44

4.53

4.67

4.82

Amps

13.0

13.3

13.7

14.2

14.0

14.3

14.8

15.3

15.2

15.5

16.0

16.6

16.2

16.6

17.1

17.8

17.2

17.6

18.2

18.9

18.2

18.7

19.3

20.0

Hi P

R22

324

025

326

425

026

928

429

628

430

632

333

732

434

836

838

436

439

241

443

240

243

345

747

7Lo

PR

106

113

123

131

112

119

130

138

116

124

135

144

122

130

142

151

128

136

149

158

132

141

154

164

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

SS-DX16SA www.daikincomfort.com 21

Expanded Cooling Data — DX16SA0601A* / CA*F4961*6D*+EEP+TXV (cont.)

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

80

1750

MBh

53.2

54.3

58.1

62.1

51.9

53.1

56.7

60.6

50.7

51.8

55.4

59.2

49.5

50.5

54.0

57.7

47.0

48.0

51.3

54.8

43.5

44.5

47.5

50.8

S/T

0.91

0.86

0.70

0.52

0.95

0.89

0.72

0.54

0.97

0.91

0.74

0.55

1.00

0.94

0.77

0.57

1.00

0.98

0.80

0.59

1.00

0.98

0.80

0.60

∆T26

2421

1726

2522

1726

2522

1726

2522

1725

2521

1723

2320

16kW

3.47

3.53

3.63

3.74

3.71

3.78

3.89

4.01

3.92

4.00

4.12

4.25

4.11

4.19

4.32

4.45

4.27

4.36

4.49

4.63

4.41

4.50

4.64

4.78

Amps

12.8

13.1

13.6

14.1

13.9

14.2

14.6

15.2

15.0

15.4

15.9

16.5

16.0

16.4

17.0

17.6

17.1

17.5

18.0

18.7

18.1

18.5

19.1

19.8

Hi P

R22

123

725

126

124

726

628

129

328

130

332

033

432

134

536

438

036

138

841

042

739

842

945

347

2Lo

PR

105

112

122

130

111

118

129

137

115

122

134

142

121

129

140

150

127

135

147

157

131

139

152

162

1625

MBh

53.2

54.3

58.1

62.1

51.9

53.1

56.7

60.6

50.7

51.8

55.4

59.2

49.5

50.5

54.0

57.7

47.0

48.0

51.3

54.8

43.5

44.5

47.5

50.8

S/T

0.91

0.86

0.70

0.52

0.95

0.89

0.72

0.54

0.97

0.91

0.74

0.55

1.00

0.94

0.77

0.57

1.00

0.98

0.80

0.59

1.00

0.98

0.80

0.60

∆T27

2622

1827

2623

1827

2623

1827

2623

1826

2622

1824

2421

17kW

3.47

3.53

3.63

3.74

3.71

3.78

3.89

4.01

3.92

4.00

4.12

4.25

4.11

4.19

4.32

4.45

4.27

4.36

4.49

4.63

4.41

4.50

4.64

4.78

Amps

12.8

13.1

13.6

14.1

13.9

14.2

14.6

15.2

15.0

15.4

15.9

16.5

16.0

16.4

17.0

17.6

17.1

17.5

18.0

18.7

18.1

18.5

19.1

19.8

Hi P

R22

123

725

126

124

726

628

129

328

130

332

033

432

134

536

438

036

138

841

042

739

842

945

347

2Lo

PR

105

112

122

130

111

118

129

137

115

122

134

142

121

129

140

150

127

135

147

157

131

139

152

162

2250

MBh

55.0

56.2

60.1

64.2

53.8

54.9

58.7

62.7

52.5

53.6

57.3

61.2

51.2

52.3

55.9

59.7

48.6

49.7

53.1

56.8

45.1

46.0

49.2

52.6

S/T

1.00

0.91

0.74

0.55

1.00

0.94

0.77

0.57

1.00

1.00

0.79

0.59

1.00

1.00

0.81

0.61

1.00

1.00

0.84

0.63

1.00

1.00

0.85

0.64

∆T22

2118

1522

2118

1521

2218

1521

2119

1520

2018

1518

1917

14kW

3.52

3.58

3.69

3.80

3.76

3.84

3.95

4.07

3.98

4.06

4.18

4.31

4.17

4.26

4.39

4.52

4.34

4.42

4.56

4.70

4.48

4.57

4.71

4.86

Amps

13.1

13.4

13.8

14.3

14.1

14.4

14.9

15.5

15.3

15.7

16.2

16.8

16.3

16.7

17.3

17.9

17.4

17.8

18.4

19.1

18.4

18.8

19.5

20.2

Hi P

R22

524

225

626

725

227

228

729

928

730

932

634

032

735

237

238

836

839

641

843

640

643

746

248

2Lo

PR

107

114

124

132

113

120

131

140

117

125

136

145

123

131

143

153

129

137

150

160

134

142

155

165

85

1750

MBh

54.1

55.1

57.8

61.6

52.8

53.9

56.4

60.2

51.6

52.6

55.1

58.8

50.3

51.3

53.7

57.3

47.8

48.7

51.0

54.5

44.3

45.1

47.3

50.4

S/T

0.96

0.93

0.84

0.68

0.99

0.96

0.87

0.70

1.00

0.98

0.89

0.72

1.00

1.00

0.92

0.74

1.00

1.00

0.95

0.77

1.00

1.00

0.96

0.78

∆T27

2725

2228

2726

2227

2726

2226

2726

2225

2625

2223

2424

21kW

3.49

3.56

3.66

3.77

3.74

3.81

3.92

4.04

3.95

4.03

4.15

4.28

4.14

4.23

4.35

4.49

4.30

4.39

4.53

4.67

4.44

4.53

4.67

4.82

Amps

13.0

13.3

13.7

14.2

14.0

14.3

14.8

15.3

15.2

15.5

16.0

16.6

16.2

16.6

17.1

17.8

17.2

17.6

18.2

18.9

18.2

18.7

19.3

20.0

Hi P

R22

324

025

326

425

026

928

429

628

430

632

333

732

434

836

838

436

439

241

443

240

243

345

747

7Lo

PR

106

113

123

131

112

119

130

138

116

124

135

144

122

130

142

151

128

136

149

158

132

141

154

164

1625

MBh

54.1

55.1

57.8

61.6

52.8

53.9

56.4

60.2

51.6

52.6

55.1

58.8

50.3

51.3

53.7

57.3

47.8

48.7

51.0

54.5

44.3

45.1

47.3

50.4

S/T

0.96

0.93

0.84

0.68

0.99

0.96

0.87

0.70

1.00

0.98

0.89

0.72

1.00

1.00

0.92

0.74

1.00

1.00

0.95

0.77

1.00

1.00

0.96

0.78

∆T28

2826

2329

2827

2328

2827

2328

2827

2326

2727

2324

2525

22kW

3.49

3.56

3.66

3.77

3.74

3.81

3.92

4.04

3.95

4.03

4.15

4.28

4.14

4.23

4.35

4.49

4.30

4.39

4.53

4.67

4.44

4.53

4.67

4.82

Amps

13.0

13.3

13.7

14.2

14.0

14.3

14.8

15.3

15.2

15.5

16.0

16.6

16.2

16.6

17.1

17.8

17.2

17.6

18.2

18.9

18.2

18.7

19.3

20.0

Hi P

R22

324

025

326

425

026

928

429

628

430

632

333

732

434

836

838

436

439

241

443

240

243

345

747

7Lo

PR

106

113

123

131

112

119

130

138

116

124

135

144

122

130

142

151

128

136

149

158

132

141

154

164

2250

MBh

56.0

57.1

59.8

63.8

54.7

55.8

58.4

62.3

53.4

54.4

57.0

60.8

52.1

53.1

55.6

59.3

49.5

50.4

52.8

56.4

45.8

46.7

48.9

52.2

S/T

1.00

0.98

0.89

0.72

1.00

1.00

0.92

0.75

1.00

1.00

0.94

0.77

1.00

1.00

0.97

0.79

1.00

1.00

1.00

0.82

1.00

1.00

1.00

0.83

∆T23

2322

1922

2322

1922

2222

1921

2222

1920

2122

1919

1920

18kW

3.54

3.61

3.71

3.82

3.79

3.87

3.98

4.10

4.01

4.09

4.21

4.34

4.20

4.29

4.42

4.56

4.37

4.46

4.60

4.74

4.51

4.61

4.75

4.90

Amps

13.2

13.5

13.9

14.4

14.2

14.6

15.0

15.6

15.4

15.8

16.3

16.9

16.5

16.9

17.4

18.1

17.5

18.0

18.5

19.2

18.6

19.0

19.6

20.4

Hi P

R22

724

525

826

925

527

429

030

229

031

233

034

433

035

537

539

137

240

042

244

041

144

246

748

7Lo

PR

108

115

125

134

114

121

132

141

119

126

138

147

125

132

145

154

131

139

152

161

135

144

157

167

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

22 www.daikincomfort.com SS-DX16SA

Expanded Cooling Data — DX16SA0611A* / CA*F4961*6D*+EEP+TXV

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

70

1550

MBh

54.2

56.2

61.6

-53

.054

.960

.1-

51.7

53.6

58.7

-50

.452

.357

.3-

47.9

49.7

54.4

-44

.446

.050

.4-

S/T

0.66

0.55

0.38

-0.

680.

570.

39-

0.70

0.58

0.40

-0.

720.

600.

42-

0.75

0.62

0.43

-0.

750.

630.

44-

∆T21

1814

-21

1914

-21

1914

-22

1914

-21

1814

-20

1713

-kW

3.75

3.83

3.95

-4.

044.

134.

27-

4.31

4.40

4.55

-4.

544.

644.

79-

4.73

4.84

5.00

-4.

905.

015.

18-

Amps

13.4

13.8

14.3

-14

.615

.015

.5-

16.0

16.4

17.0

-17

.217

.618

.3-

18.4

18.8

19.5

-19

.520

.020

.8-

Hi P

R22

724

424

8-

257

276

280

-29

231

431

8-

333

358

363

-35

938

639

2-

426

458

464

-Lo

PR

113

116

127

-11

612

013

1-

120

124

135

-12

312

713

9-

126

130

141

-12

913

314

5-

1750

MBh

55.9

57.9

63.4

-54

.656

.562

.0-

53.3

55.2

60.5

-52

.053

.959

.0-

49.4

51.2

56.1

-45

.747

.451

.9-

S/T

0.69

0.58

0.40

-0.

710.

600.

41-

0.73

0.61

0.42

-0.

760.

630.

44-

0.78

0.66

0.45

-0.

790.

660.

46-

∆T20

1813

-20

1813

-20

1813

-21

1814

-20

1813

-19

1612

-kW

3.78

3.86

3.99

-4.

084.

174.

31-

4.34

4.44

4.59

-4.

574.

684.

83-

4.77

4.88

5.05

-4.

945.

065.

23-

Amps

13.6

13.9

14.4

-14

.815

.115

.7-

16.1

16.6

17.2

-17

.317

.818

.4-

18.5

19.0

19.7

-19

.720

.221

.0-

Hi P

R22

924

725

0-

259

279

283

-29

531

732

2-

336

361

366

-36

339

039

6-

430

462

469

-Lo

PR

114

117

128

-11

712

113

2-

121

125

136

-12

412

814

0-

127

131

143

-13

013

414

6-

2000

MBh

56.1

58.2

63.7

-54

.856

.862

.3-

53.5

55.5

60.8

-52

.254

.159

.3-

49.6

51.4

56.3

-45

.947

.652

.2-

S/T

0.70

0.58

0.40

-0.

720.

600.

42-

0.74

0.62

0.43

-0.

770.

640.

44-

0.80

0.66

0.46

-0.

800.

670.

46-

∆T18

1612

-18

1612

-18

1612

-18

1612

-18

1612

-17

1511

-kW

3.81

3.89

4.02

-4.

114.

204.

34-

4.38

4.48

4.63

-4.

614.

724.

88-

4.81

4.92

5.09

-4.

985.

105.

27-

Amps

13.7

14.1

14.6

-14

.915

.315

.8-

16.3

16.7

17.3

-17

.518

.018

.6-

18.7

19.2

19.9

-19

.920

.421

.2-

Hi P

R23

224

925

3-

262

282

286

-29

832

032

5-

339

365

370

-36

639

440

0-

434

467

474

-Lo

PR

115

119

129

-11

812

213

3-

122

126

138

-12

613

014

1-

128

132

144

-13

113

514

8-

75

1550

MBh

55.1

56.8

61.5

66.0

53.9

55.5

60.0

64.4

52.6

54.1

58.6

62.9

51.3

52.8

57.2

61.4

48.7

50.2

54.3

58.3

45.1

46.5

50.3

54.0

S/T

0.75

0.67

0.51

0.33

0.77

0.69

0.52

0.34

0.79

0.71

0.54

0.35

0.82

0.73

0.55

0.36

0.85

0.76

0.58

0.37

0.86

0.77

0.58

0.37

∆T24

2318

1325

2319

1325

2319

1325

2319

1325

2319

1323

2117

12kW

3.75

3.83

3.95

4.08

4.04

4.13

4.27

4.41

4.31

4.40

4.55

4.70

4.54

4.64

4.79

4.96

4.73

4.84

5.00

5.18

4.90

5.01

5.18

5.36

Amps

13.4

13.8

14.3

14.8

14.6

15.0

15.5

16.2

16.0

16.4

17.0

17.7

17.2

17.6

18.3

19.0

18.4

18.8

19.5

20.3

19.5

20.0

20.8

21.6

Hi P

R22

724

424

825

325

727

628

028

629

231

431

832

633

335

836

337

135

938

639

240

042

645

846

447

5Lo

PR

113

116

127

135

116

120

131

139

120

124

135

144

123

127

139

148

126

130

141

151

129

133

145

154

1750

MBh

56.8

58.5

63.3

67.9

55.5

57.1

61.8

66.4

54.2

55.8

60.4

64.8

52.8

54.4

58.9

63.2

50.2

51.7

55.9

60.0

46.5

47.9

51.8

55.6

S/T

0.78

0.70

0.53

0.34

0.81

0.73

0.55

0.35

0.83

0.74

0.56

0.36

0.86

0.77

0.58

0.37

0.89

0.80

0.60

0.39

0.90

0.80

0.61

0.39

∆T23

2218

1224

2218

1224

2218

1224

2218

1224

2218

1222

2017

11kW

3.78

3.86

3.99

4.12

4.08

4.17

4.31

4.45

4.34

4.44

4.59

4.74

4.57

4.68

4.83

5.00

4.77

4.88

5.05

5.22

4.94

5.06

5.23

5.41

Amps

13.6

13.9

14.4

15.0

14.8

15.1

15.7

16.3

16.1

16.6

17.2

17.9

17.3

17.8

18.4

19.2

18.5

19.0

19.7

20.5

19.7

20.2

21.0

21.8

Hi P

R22

924

725

025

625

927

928

328

929

531

732

232

933

636

136

637

436

339

039

640

443

046

246

947

9Lo

PR

114

117

128

137

117

121

132

141

121

125

136

145

124

128

140

149

127

131

143

152

130

134

146

156

2000

MBh

57.1

58.8

63.6

68.3

55.8

57.4

62.1

66.7

54.4

56.0

60.7

65.1

53.1

54.7

59.2

63.5

50.4

51.9

56.2

60.3

46.7

48.1

52.1

55.9

S/T

0.79

0.71

0.54

0.35

0.82

0.74

0.56

0.36

0.84

0.75

0.57

0.37

0.87

0.78

0.59

0.38

0.90

0.81

0.61

0.39

0.91

0.82

0.62

0.40

∆T21

1916

1121

1916

1121

1916

1121

2016

1121

1916

1120

1815

10kW

3.81

3.89

4.02

4.15

4.11

4.20

4.34

4.49

4.38

4.48

4.63

4.78

4.61

4.72

4.88

5.04

4.81

4.92

5.09

5.26

4.98

5.10

5.27

5.46

Amps

13.7

14.1

14.6

15.1

14.9

15.3

15.8

16.5

16.3

16.7

17.3

18.0

17.5

18.0

18.6

19.4

18.7

19.2

19.9

20.7

19.9

20.4

21.2

22.0

Hi P

R23

224

925

325

826

228

228

629

229

832

032

533

233

936

537

037

836

639

440

040

843

446

747

448

4Lo

PR

115

119

129

138

118

122

133

142

122

126

138

147

126

130

141

151

128

132

144

154

131

135

148

157

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

SS-DX16SA www.daikincomfort.com 23

Expanded Cooling Data — DX16SA0611A* / CA*F4961*6D*+EEP+TXV (cont.)

Ou

tdo

or

Am

bien

t Te

mpe

ratu

re65

ºF75

ºF85

ºF95

ºF10

5ºF

115º

FEn

teri

ng

Indo

or

Wet

Bu

lb T

empe

ratu

reID

BA

irfl

ow

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

5963

6771

80

1550

MBh

56.1

57.4

61.3

65.5

54.8

56.0

59.9

64.0

53.5

54.7

58.4

62.5

52.2

53.4

57.0

60.9

49.6

50.7

54.2

57.9

45.9

46.9

50.2

53.6

S/T

0.82

0.77

0.63

0.47

0.85

0.80

0.65

0.48

0.87

0.82

0.66

0.50

0.90

0.84

0.69

0.51

0.93

0.87

0.71

0.53

0.94

0.88

0.72

0.54

∆T27

2623

1828

2623

1828

2623

1828

2723

1927

2623

1826

2521

17kW

3.75

3.83

3.95

4.08

4.04

4.13

4.27

4.41

4.31

4.40

4.55

4.70

4.54

4.64

4.79

4.96

4.73

4.84

5.00

5.18

4.90

5.01

5.18

5.36

Amps

13.4

13.8

14.3

14.8

14.6

15.0

15.5

16.2

16.0

16.4

17.0

17.7

17.2

17.6

18.3

19.0

18.4

18.8

19.5

20.3

19.5

20.0

20.8

21.6

Hi P

R22

724

424

825

325

727

628

028

629

231

431

832

633

335

836

337

135

938

639

240

042

645

846

447

5Lo

PR

113

116

127

135

116

120

131

139

120

124

135

144

123

127

139

148

126

130

141

151

129

133

145

154

1750

MBh

57.8

59.1

63.1

67.5

56.5

57.7

61.6

65.9

55.1

56.3

60.2

64.3

53.8

55.0

58.7

62.8

51.1

52.2

55.8

59.6

47.3

48.4

51.7

55.2

S/T

0.86

0.81

0.66

0.49

0.89

0.84

0.68

0.51

0.91

0.86

0.70

0.52

0.94

0.88

0.72

0.54

1.00

0.92

0.75

0.56

1.00

0.93

0.75

0.56

∆T26

2522

1726

2522

1826

2522

1827

2622

1827

2522

1725

2420

16kW

3.78

3.86

3.99

4.12

4.08

4.17

4.31

4.45

4.34

4.44

4.59

4.74

4.57

4.68

4.83

5.00

4.77

4.88

5.05

5.22

4.94

5.06

5.23

5.41

Amps

13.6

13.9

14.4

15.0

14.8

15.1

15.7

16.3

16.1

16.6

17.2

17.9

17.3

17.8

18.4

19.2

18.5

19.0

19.7

20.5

19.7

20.2

21.0

21.8

Hi P

R22

924

725

025

625

927

928

328

929

531

732

232

933

636

136

637

436

339

039

640

443

046

246

947

9Lo

PR

114

117

128

137

117

121

132

141

121

125

136

145

124

128

140

149

127

131

143

152

130

134

146

156

2000

MBh

58.1

59.4

63.4

67.8

56.7

58.0

61.9

66.2

55.4

56.6

60.5

64.6

54.0

55.2

59.0

63.1

51.3

52.5

56.0

59.9

47.6

48.6

51.9

55.5

S/T

0.87

0.82

0.66

0.50

0.90

0.85

0.69

0.51

0.93

0.87

0.71

0.53

0.96

0.90

0.73

0.55

1.00

0.93

0.76

0.57

1.00

0.94

0.76

0.57

∆T23

2219

1524

2320

1624

2320

1624

2320

1624

2219

1622

2118

15kW

3.81

3.89

4.02

4.15

4.11

4.20

4.34

4.49

4.38

4.48

4.63

4.78

4.61

4.72

4.88

5.04

4.81

4.92

5.09

5.26

4.98

5.10

5.27

5.46

Amps

13.7

14.1

14.6

15.1

14.9

15.3

15.8

16.5

16.3

16.7

17.3

18.0

17.5

18.0

18.6

19.4

18.7

19.2

19.9

20.7

19.9

20.4

21.2

22.0

Hi P

R23

224

925

325

826

228

228

629

229

832

032

533

233

936

537

037

836

639

440

040

843

446

747

448

4Lo

PR

115

119

129

138

118

122

133

142

122

126

138

147

126

130

141

151

128

132

144

154

131

135

148

157

85

1550

MBh

57.1

58.2

61.0

65.0

55.8

56.9

59.6

63.5

54.5

55.5

58.1

62.0

53.1

54.2

56.7

60.5

50.5

51.4

53.9

57.5

46.7

47.7

49.9

53.2

S/T

0.86

0.83

0.75

0.61

0.89

0.86

0.78

0.63

0.91

0.88

0.80

0.65

0.94

0.91

0.82

0.67

0.98

0.94

0.85

0.69

0.99

0.95

0.86

0.70

∆T29

2927

2329

2927

2429

2927

2430

2928

2429

2927

2427

2725

22kW

3.75

3.83

3.95

4.08

4.04

4.13

4.27

4.41

4.31

4.40

4.55

4.70

4.54

4.64

4.79

4.96

4.73

4.84

5.00

5.18

4.90

5.01

5.18

5.36

Amps

13.4

13.8

14.3

14.8

14.6

15.0

15.5

16.2

16.0

16.4

17.0

17.7

17.2

17.6

18.3

19.0

18.4

18.8

19.5

20.3

19.5

20.0

20.8

21.6

Hi P

R22

724

424

825

325

727

628

028

629

231

431

832

633

335

836

337

135

938

639

240

042

645

846

447

5Lo

PR

113

116

127

135

116

120

131

139

120

124

135

144

123

127

139

148

126

130

141

151

129

133

145

154

1750

MBh

58.8

60.0

62.8

67.0

57.5

58.6

61.3

65.4

56.1

57.2

59.9

63.9

54.7

55.8

58.4

62.3

52.0

53.0

55.5

59.2

48.2

49.1

51.4

54.8

S/T

0.90

0.87

0.78

0.64

0.93

0.90

0.81

0.66

0.96

0.92

0.83

0.68

0.99

0.95

0.86

0.70

1.00

0.99

0.89

0.72

1.00

1.00

0.90

0.73

∆T28

2726

2228

2826

2328

2826

2328

2826

2327

2826

2325

2624

21kW

3.78

3.86

3.99

4.12

4.08

4.17

4.31

4.45

4.34

4.44

4.59

4.74

4.57

4.68

4.83

5.00

4.77

4.88

5.05

5.22

4.94

5.06

5.23

5.41

Amps

13.6

13.9

14.4

15.0

14.8

15.1

15.7

16.3

16.1

16.6

17.2

17.9

17.3

17.8

18.4

19.2

18.5

19.0

19.7

20.5

19.7

20.2

21.0

21.8

Hi P

R22

924

725

025

625

927

928

328

929

531

732

232

933

636

136

637

436

339

039

640

443

046

246

947

9Lo

PR

114

117

128

137

117

121

132

141

121

125

136

145

124

128

140

149

127

131

143

152

130

134

146

156

2000

MBh

59.1

60.3

63.1

67.3

57.7

58.8

61.6

65.8

56.4

57.4

60.2

64.2

55.0

56.0

58.7

62.6

52.2

53.2

55.8

59.5

48.4

49.3

51.7

55.1

S/T

0.91

0.88

0.80

0.65

0.95

0.91

0.82

0.67

0.97

0.94

0.84

0.69

1.00

0.97

0.87

0.71

1.00

1.00

0.91

0.73

1.00

1.00

0.91

0.74

∆T25

2423

2025

2523

2025

2523

2025

2524

2024

2423

2022

2322

19kW

3.81

3.89

4.02

4.15

4.11

4.20

4.34

4.49

4.38

4.48

4.63

4.78

4.61

4.72

4.88

5.04

4.81

4.92

5.09

5.26

4.98

5.10

5.27

5.46

Amps

13.7

14.1

14.6

15.1

14.9

15.3

15.8

16.5

16.3

16.7

17.3

18.0

17.5

18.0

18.6

19.4

18.7

19.2

19.9

20.7

19.9

20.4

21.2

22.0

Hi P

R23

224

925

325

826

228

228

629

229

832

032

533

233

936

537

037

836

639

440

040

843

446

747

448

4Lo

PR

115

119

129

138

118

122

133

142

122

126

138

147

126

130

141

151

128

132

144

154

131

135

148

157

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AH

RI c

ondi

tions

Amps

= o

utdo

or u

nit a

mps

(com

p.+f

an)

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ction

ser

vice

val

ves.

kW =

Tot

al s

yste

m p

ower

AHRI Ratings

24 www.daikincomfort.com SS-DX16SA

All AHRI system ratings are accessible in the Unitary Matchup Tool via Daikin City or in the Daikin System Configurator tool via PartnerLink.

SS-DX16SA www.daikincomfort.com 25

87

56

41

23

86

74

51

23

E D B AC

E D B AC

CON

FID

ENTI

AL P

ROPE

RTY

OF

THE

GO

OD

MAN

MAN

UFA

CTU

RIN

G C

OM

PAN

Y, L

.P. N

OT

TO B

E D

ISCL

OSE

D T

O O

THER

S, C

OPI

ED, O

R U

SED

FO

R AN

Y PU

RPO

SEEX

CEPT

AS

AUTH

ORI

ZED

IN W

RITI

NG

. M

UST

BE

RETU

RNED

UPO

N D

EMAN

D, O

N C

OM

PLET

ION

OF

ORD

ER, O

R O

THER

PU

RPO

SE F

OR

WH

ICH

IT W

AS L

ENT.

COM

PON

ENTS

AN

D M

ATER

IALS

SPE

CIFI

ED H

EREI

N W

ILL

ALSO

CO

NFO

RM T

O T

HE

APPL

ICAB

LE S

ECTI

ON

OF

GO

OD

MAN

MSP

824

.01

WO

RKM

ANSH

IPST

AND

ARD

FOR

FIT,

FEE

L AN

D F

INIS

H.

SPE

CIAL

CH

ARAC

TERI

STIC

S:

=6S

IGM

A

=

CRIT

ICAL

CH

ARAC

TERI

STIC

= S

IGN

IFIC

ANT

CHAR

ACTE

RIST

ICSC

CC6s

ENG

: D

WN

BY:

DO

NO

T SC

ALE

DRAW

ING AREV

SHT

1 O

F 1

TOLE

RAN

CES:

ANG

LES

± 1.

5°.X

: ±

.1.X

X : ±

.03

.XXX

: ±

.015

HO

LE Ø

: ±

.005

TUBE

CU

T LG

: ± .0

63

DRA

WIN

G T

O B

E IN

TERP

RETE

D IN

ACCO

RDAN

CE W

ITH

ASM

E Y1

4.10

0

DIM

ENSI

ON

S AR

E IN

INCH

ESU

NLE

SS O

THER

WIS

E N

OTE

D

ECN

REV

DESC

RIPT

ION

CHK

D

DAT

EXX

XXXX

XA

-G

LZO

NE

XXXX

X

Dimensions

Dai

kin

Man

ufac

turin

g Co

., LL

C

DX1

6SA

Mo

del

Dim

ensi

on

s

W”

D”

H”

DX1

6SA0

181A

*29

2932

¼

DX1

6SA0

241A

*29

2932

¼

DX1

6SA0

301A

*29

2936

¼

DX1

6SA0

311A

*29

2938

¼

DX1

6SA0

361A

*29

2938

¼

DX1

6SA0

371A

*35

½35

½36

¼

DX1

6SA0

421A

*35

½35

½36

¼

DX1

6SA0

481A

*35

½35

½40

DX1

6SA0

601A

*35

½35

½38

¼

DX1

6SA0

611A

*35

½35

½40

26 www.daikincomfort.com SS-DX16SA

Wiri

ng is

sub

ject

to c

hang

e. A

lway

s re

fer

to t

he w

iring

dia

gram

on

the

unit

for t

he m

ost u

p-to

-dat

e w

iring

.⚠

W

ARN

ING

Hig

h Vo

ltag

e: D

isco

nnec

t al

l po

wer

bef

ore

serv

icin

g or

ins

talli

ng t

his

unit.

Mul

tiple

pow

er

sour

ces

may

be

pres

ent.

Fai

lure

to d

o so

may

cau

se p

rope

rty

dam

age,

per

sona

l inj

ury,

or d

eath

.⚡

Wiring Diagram — DX16SA0181-48** / 611**

CO

MP

ALTERNATE DOUBLEPOLE CONTACTOR ONLY

IO

T1

C

MAINR

AUX

5

S

SR

SA

21

RC

CF

SC

T2

CL1

L2

(IF U

SED

)

CH

C

F

MAIN

AUX

IO CM

CY

C

BLCY

LVJB

COM

PONE

NT C

ODE

C --

------

------

- CO

NTA

CTO

RC

SM --

------

CO

RES

ENSE

MO

DULE

CM

-----

------

- OU

TDO

OR

FAN

MO

TOR

CO

MP

------

-- C

OM

PRES

SOR

HPS

-----

------

HIG

H P

RES

SUR

E SW

ITC

HIO

-----

------

--- IN

TERN

AL O

VER

LOAD

LVJB

-----

-----

LOW

VO

LTAG

E JU

NCTI

ON

BO

XR

CCF

------

--- R

UN C

APAC

ITO

R F

OR

CO

MPR

ESSO

R &

FAN

SA --

------

-----

STAR

T AS

SIST

SC --

------

-----

STAR

T C

APAC

ITO

R F

OR

CO

MPR

ESSO

R (O

PTIO

NAL

)SR

-----

------

-- ST

ART

REL

AY F

OR

CO

MPR

ESSO

R (O

PTIO

NAL

)LP

S ---

------

--- L

OW

PR

ESSU

RE

SWIT

CH

CO

NTR

OLS

SH

OW

N W

ITH

TH

ERM

OST

AT IN

'OFF

' PO

SITI

ON

.

OUT

DO

OR

PO

WER

SU

PPLY

SEE

RAT

ING

PLA

TE

WIR

ING

CODE

FAC

TOR

Y W

IRIN

GH

IGH

VO

LTAG

ELO

W V

OLT

AGE

OPT

ION

AL H

IGH

VO

LTAG

E

FIEL

D W

IRIN

GH

IGH

VO

LTAG

ELO

W V

OLT

AGE

CC

PUYL

YL

SC

RD

BL

RD

YL

RD

RD

BKBK

BK

C

T1 L1

T2 L2

RC

CF

FC

HER

M

YL

YL

BRR

DPUYL

RD

YL

RD

BK

CO

MP

IO

CMAU

X

MAI

N

BKBRPU

SR

5 21

BK YL

BL

HPS

BL/P

K

BL/P

K

COLO

R CO

DEBK

-----

------

---- B

LAC

KBL

-----

------

---- B

LUE

BL/P

K ---

------

- BLU

E/PI

NK

STR

IPE

BR --

------

------

- BR

OW

NO

R --

------

------

- OR

ANG

EPU

-----

------

---- P

UR

PLE

RD --

------

------

- RED

WH

-----

------

--- W

HIT

EYL

-----

------

---- Y

ELLO

WYL

/PK

------

------

--- Y

ELLO

W /P

INK

STR

IPE

HPS

NO

TES:

1) T

O IN

DO

OR

UN

IT L

OW

VO

LTAG

E

TER

MIN

AL B

LOC

K &

IND

OO

R T

HER

MO

STAT

.2)

STA

RT

ASSI

ST F

ACTO

RY

EQU

IPPE

D W

HEN

REQ

UIR

ED.

3) U

SE C

OPP

ER C

OND

UCTO

RS

ON

LY.

RD

S

A(IF

USE

D)

NO

TE 2

MAI

N

CIO

R

S

AUX

CO

MP

IO

T1

C

MAINR

AUX

5

S

SR

CSM

SA

21

RC

CF

SC

T2

CL1

L2

(IF U

SED

)

CH

CC S M

F

MAIN

AUX

IO CM

CY

C

YC

BLCY

LVJB

SEE

NO

TE 1

CBK

PC

CSM

BLYL

RD

BK

LVJB

CONT

ROL

BOX

SC

RD

BL

RD

PUR

D

RD

BKBK

BK

C

T1 L1

T2 L2

RC

CF

FC

HER

M

YL

YL

BRR

DPUYL

RD

YL

RD

BK

CO

MP

IO

CMAU

X

MAI

N

BKBRPU

5 21

BK YL

BL

EQU

IPM

ENT

GR

OUN

D

BL/P

KH

PSBL

/PK

BL/P

K

HPS

RD

S

A(IF

USE

D)

NO

TE 2

NO

TE 3

LPS

CIO

R

S

AUX

0140

R00

275-

C

YL/P

KYL

/PK

LPS

Y

YL

P

YL

USE

N.E

.C. C

LASS

2 W

IRE

T1 L1

T2 L2

ALTE

RN

ATE

DO

UBL

EPO

LE C

ON

TAC

TOR

YL BL/P

K

YL/P

K

YL/P

K

SEE

NO

TE 1

SS-DX16SA www.daikincomfort.com 27

Wiri

ng is

sub

ject

to c

hang

e. A

lway

s re

fer

to t

he w

iring

dia

gram

on

the

unit

for t

he m

ost u

p-to

-dat

e w

iring

.

W

ARN

ING

Hig

h Vo

ltag

e: D

isco

nnec

t al

l po

wer

bef

ore

serv

icin

g or

ins

talli

ng t

his

unit.

Mul

tiple

pow

er

sour

ces

may

be

pres

ent.

Fai

lure

to d

o so

may

cau

se p

rope

rty

dam

age,

per

sona

l inj

ury,

or d

eath

.⚡

Wiring Diagram — DX16SA0601**

USE

N.E

.C. C

LASS

2 W

IRE

CO

MP

ALTERNATE DOUBLEPOLE CONTACTOR ONLY

IO

T1

C

MAINR

AUX

5

S

SR

SA

21

RC

C

SC

T2

CL1

L2

(IF U

SED

)

CH

C

C

C

0140

R00

287-

A

BL

Y CLVJB

COLO

R C O

DEBK

-----

------

---- B

LAC

KBL

-----

------

---- B

LUE

BR --

------

------

- BRO

WN

OR

-----

------

---- O

RAN

GE

PU --

------

------

- PUR

PLE

RD --

------

------

- RED

WH

-----

------

--- W

HIT

EYL

-----

------

-----

YELL

OW

GR

/YL-

------

-----G

REEN

/YEL

LOW

STR

IPE

GR

------

------

---- G

REEN

CO

NTRO

L BO

X

COM

PONE

NT C

ODE

C --

------

------

- CON

TACT

OR

CM

-----

------

- OUT

DOO

R F

AN M

OTO

RCO

MP

------

-- C

OM

PRES

SOR

IO --

------

------

INTE

RNAL

OVE

RLO

ADLV

JB --

------

-- LO

W V

OLT

AGE

JUNC

TIO

N B

OX

RCC

-----

---- R

UN

CAP

ACIT

OR

FO

R C

OM

PRES

SOR

SA --

------

-----

STAR

T AS

SIST

SC --

------

-----

STAR

T C

APAC

ITO

R F

OR

CO

MPR

ESSO

R (O

PTIO

NAL)

SR --

------

-----

STAR

T R

ELAY

FO

R C

OM

PRES

SOR

(OPT

IONA

L)CH

------

------

--CR

ANKC

ASE

HEAT

ERCO

NTRO

LS S

HOW

N W

ITH

THE

RMO

STAT

IN 'O

FF' P

OSI

TIO

N.

OUT

DOO

R P

OW

ER S

UPPL

YSE

E RA

TIN

G P

LATE

WIR

ING

CO

DEFA

CTO

RY W

IRIN

GH

IGH

VO

LTAG

ELO

W V

OLT

AGE

OPT

IONA

L H

IGH

VO

LTAG

E

FIEL

D W

I RIN

GH

IGH

VO

LTAG

E

Y

YL

YL

C

R

S

RD

BKAU

X

MAI

N

CO

MP

SC

RD

BL

RC

C YL

PU

YL

SR

5 21

BK YL

BL

RD

YLBL

RD

RD

BKBK

BK

C

T1 L1

T2 L2

SA

(IF U

SED

)NO

TE 2

EQU

IPM

ENT

GRO

UND

SEE

NOTE

3

BRBKYL

T1 L1

T2 L2

ALTE

RNAT

E DO

UBL

E PO

LECO

NTAC

TOR

NO

TES:

1) T

O IN

DOO

R U

NIT

LO

W V

OLT

AGE

TERM

INAL

BLO

CK

&

INDO

OR

THE

RMO

STAT

.2)

STA

RT A

SSIS

T FA

CTO

RY E

QU

IPPE

D W

HEN

REQ

UIR

ED.

3) U

SE C

OPP

ER C

ON

DUCT

ORS

ON

LY.

HC

RD

RD R

D

WH

BL

GND L1 L2 CM

CF

GR

/YL

GR

BKBK

GR

BKBK

CH

CH

CM L2

L1

CM

BLW

H YL

GR

/YL

SEE

NOTE

1

28 www.daikincomfort.com SS-DX16SA

Accessories

Model DescriptionDX16SA0181A*

DX16SA0241A*

DX16SA0301A*

DX16SA 0311A*

DX16SA0361A*

DX16SA 0371A*

DX16SA0421A*

DX16SA0481A*

DX16SA0601A*

DX16SA0611A*

ABK-20 Anchor Bracket Kit ^ X X X X X X X X X X

ABK-21 Anchor Bracket Kit ^

ASC-01 Anti-Short Cycle Kit X X X X X X X X X X

CSR-U-1 Hard-start Kit X X X X X X

CSR-U-2 Hard-start Kit X X X X X X

CSR-U-3 Hard-start Kit X X X

0130R00000S Low-Pressure Switch Kit X X X X X X X X X X

LAKT01A Freeze-Stat Kit X X X X X X X X X X

TXV-30² TXV Kit X X X X

TXV-42² TXV Kit X X X

TXV-48² TXV Kit X

TXV-60² TXV Kit X X

^ Contains 20 brackets; four brackets needed to anchor unit to pad¹ Field-installed, non-bleed, expansion valve kit

SS-DX16SA www.daikincomfort.com 29

Notes

30 www.daikincomfort.com SS-DX16SA

Our continuing commitment to quality products may mean a change in specifications without notice. ©2019 • Houston, Texas • Printed in the USA

Notes