dynamic shock modeling darren barlow regional technical manager perforating
DESCRIPTION
Key Areas Workplusplace.com Fineartamerica.comTRANSCRIPT
![Page 1: Dynamic Shock Modeling Darren Barlow Regional Technical Manager Perforating](https://reader036.vdocument.in/reader036/viewer/2022062302/5a4d1b3c7f8b9ab05999f1ae/html5/thumbnails/1.jpg)
Dynamic Shock Modeling
Darren BarlowRegional Technical Manager
Perforating
![Page 2: Dynamic Shock Modeling Darren Barlow Regional Technical Manager Perforating](https://reader036.vdocument.in/reader036/viewer/2022062302/5a4d1b3c7f8b9ab05999f1ae/html5/thumbnails/2.jpg)
Leon Moisseiff
What if he had the ability to model?
What does it cost if you have a major failure on a well?
Disaster is intriguing if it’s not you!
![Page 3: Dynamic Shock Modeling Darren Barlow Regional Technical Manager Perforating](https://reader036.vdocument.in/reader036/viewer/2022062302/5a4d1b3c7f8b9ab05999f1ae/html5/thumbnails/3.jpg)
Key Areas
Workplusplace.com
Fineartamerica.com
![Page 4: Dynamic Shock Modeling Darren Barlow Regional Technical Manager Perforating](https://reader036.vdocument.in/reader036/viewer/2022062302/5a4d1b3c7f8b9ab05999f1ae/html5/thumbnails/4.jpg)
Modeling versus Reality 275’ of 6 ½ guns
Reservoir 15K
Red – Tubing Movement
Blue – Packer Load
Cyan - Tubing Load C/T
830,000 lbf
1.00
-1.00
1000
-500
![Page 5: Dynamic Shock Modeling Darren Barlow Regional Technical Manager Perforating](https://reader036.vdocument.in/reader036/viewer/2022062302/5a4d1b3c7f8b9ab05999f1ae/html5/thumbnails/5.jpg)
Avoiding NPT
Packer
60m 7” UHSD
Firing Head
10m 3 ½ 12.95 ppf
10m 3 ½ 12.95 ppf
Release
Ported Sub
![Page 6: Dynamic Shock Modeling Darren Barlow Regional Technical Manager Perforating](https://reader036.vdocument.in/reader036/viewer/2022062302/5a4d1b3c7f8b9ab05999f1ae/html5/thumbnails/6.jpg)
Pressures Equals Loading
Red – Tubing Movement
Blue – Packer Load
Cyan - Tubing Load C/T
![Page 7: Dynamic Shock Modeling Darren Barlow Regional Technical Manager Perforating](https://reader036.vdocument.in/reader036/viewer/2022062302/5a4d1b3c7f8b9ab05999f1ae/html5/thumbnails/7.jpg)
Strengthening the BHA
Packer
60m 7” 18 spf UHSD
Firing Head
10m 3 ½ 12.95 ppf
10m 3 ½ 12.95 ppf
Release
Ported Sub
10m 5 ½ Drillpipe
10m 5 ½ Drillpipe
![Page 8: Dynamic Shock Modeling Darren Barlow Regional Technical Manager Perforating](https://reader036.vdocument.in/reader036/viewer/2022062302/5a4d1b3c7f8b9ab05999f1ae/html5/thumbnails/8.jpg)
Confined Spaces
![Page 9: Dynamic Shock Modeling Darren Barlow Regional Technical Manager Perforating](https://reader036.vdocument.in/reader036/viewer/2022062302/5a4d1b3c7f8b9ab05999f1ae/html5/thumbnails/9.jpg)
Isolation plug
Running Tool
Loss of well
10
Isolation Packer
![Page 10: Dynamic Shock Modeling Darren Barlow Regional Technical Manager Perforating](https://reader036.vdocument.in/reader036/viewer/2022062302/5a4d1b3c7f8b9ab05999f1ae/html5/thumbnails/10.jpg)
Movement
11
CWOP – 5’ Depth of the well was 25,000+
![Page 11: Dynamic Shock Modeling Darren Barlow Regional Technical Manager Perforating](https://reader036.vdocument.in/reader036/viewer/2022062302/5a4d1b3c7f8b9ab05999f1ae/html5/thumbnails/11.jpg)
Bridge Plug- Well Integrity
36m 7” Guns
Bridge Plug
Retrievable Packer
10m
62m
*
*
Packer
Bridge Plug
16
8
24
32
40
![Page 12: Dynamic Shock Modeling Darren Barlow Regional Technical Manager Perforating](https://reader036.vdocument.in/reader036/viewer/2022062302/5a4d1b3c7f8b9ab05999f1ae/html5/thumbnails/12.jpg)
Unknowns
![Page 13: Dynamic Shock Modeling Darren Barlow Regional Technical Manager Perforating](https://reader036.vdocument.in/reader036/viewer/2022062302/5a4d1b3c7f8b9ab05999f1ae/html5/thumbnails/13.jpg)
Component Failure
35m of guns
Champ IVPacker
Formation test string
Pup Joint w/ Firing Heads
Why was Failure NOT Predicted?
![Page 14: Dynamic Shock Modeling Darren Barlow Regional Technical Manager Perforating](https://reader036.vdocument.in/reader036/viewer/2022062302/5a4d1b3c7f8b9ab05999f1ae/html5/thumbnails/14.jpg)
Post Failure Analysis
Gauge Analysis:
Reported k = 0.2 md
Actual k = 0.02 md
Changed perm and re-ran model
Predicted failure @ 3244m
Actual failure @ 3245m
![Page 15: Dynamic Shock Modeling Darren Barlow Regional Technical Manager Perforating](https://reader036.vdocument.in/reader036/viewer/2022062302/5a4d1b3c7f8b9ab05999f1ae/html5/thumbnails/15.jpg)
How can modeling help your completion challenges?
Darren BarlowRegional Technical Manager- Perforating
Summary