e g h hot box i stud e j brochure h stud g 2016 · 2016. 12. 6. · osborne park w a 47- 5 3...

2
Available from: Warranty: Provided your Real Flame Gas Fire is installed by a licensed Gas Fitter in accordance with our installation instructions and any other relevant codes and operated in accordance with our operating manual, your firebox is warranted for a period of 15 years and all other parts for 2 years from date of purchase. Refer to our web site or our IOM’s for a comprehensive warranty. www.realflame.com.au Richmond VIC 300 Swan Street T 03 9428 4443 Geelong VIC 2a Gordon Avenue T 03 5229 0844 Dandenong Sth VIC 3/328 South Gippsland Highway T 03 9702 7853 Chatswood NSW 546 Pacific Highway T 02 8905 0189 Miranda NSW 36 Kareena Road T 02 8513 6202 Norwood SA 173 Magill Road T 08 8132 0371 Milton QLD 46 Douglas Street T 07 3368 2011 Osborne Park WA 47-53 McDonald Street T 08 9444 9900 Fyshwick ACT 88 Wollongong Street T 02 6280 5522 Head Office, Factory and Showroom: Scoresby VIC 1340 Ferntree Gully Road T 03 8706 2000 F 03 8706 2001 Free on site advisory service HOT BOX BROCHURE 2016 HOT BOX A B NOTE: Install unit and flue prior to plastering. NOTE: Plaster is to finish flush with the fascia as shown. Floor leve Fascia Mantel Stud Firebox l frame out. Ensure unit is positioned at finished hearth height. Fascia Firebox Plaster Stud I Firebox J K Hearth Flue J Clearance to Combustibles PLAN FRONT LHS H G F D E E C Fire A B C D E F G H NG Mj/h LP Mj/h GPO REQ’D VENTILATION I J K 26 23 NO 18000mm2 920 915 425 700 460 305 150 200 25 100 25 CAST FASCIA A PLAN FRONT LHS PLAN FRONT LHS FRONT LHS D D D E F L M D F E L M A C B PLAN F E E F Hot Box Pyrotech Heatseeker A B C D E F NG Mj/h LP Mj/h GPO REQ’D VENTILATION 570 HOT BOX * 230 580 465 240 26 23 NO 40000mm2 460 L M - - *needs a cast fascia Refer to TRIMS section for 4 sided trim dimensions

Upload: others

Post on 01-Apr-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: E G H HOT BOX I Stud E J BROCHURE H Stud G 2016 · 2016. 12. 6. · Osborne Park W A 47- 5 3 McDonald Street T 08 94 44 9900 Fy shw ick ACT 88 W o llongon g Str eet T 02 62 80 5522

Available from: Warranty: Provided your Real Flame Gas Fire is installed by a licensed Gas Fitter in accordance with our installation instructions and any other relevant codes and operated in accordance with our operating manual, your firebox is warranted for a period of 15 years and all other parts for 2 years from date of purchase. Refer to our web site or our IOM’s for a comprehensive warranty.

www.realflame.com.au

Richmond VIC300 Swan StreetT 03 9428 4443

Geelong VIC2a Gordon AvenueT 03 5229 0844

Dandenong Sth VIC3/328 South Gippsland HighwayT 03 9702 7853

Chatswood NSW546 Pacific HighwayT 02 8905 0189

Miranda NSW36 Kareena RoadT 02 8513 6202

Norwood SA173 Magill RoadT 08 8132 0371

Milton QLD46 Douglas StreetT 07 3368 2011

Osborne Park WA47-53 McDonald StreetT 08 9444 9900

Fyshwick ACT88 Wollongong StreetT 02 6280 5522

Head Office, Factoryand Showroom:Scoresby VIC1340 Ferntree Gully RoadT 03 8706 2000F 03 8706 2001

Free on site advisory service

HOT BOX BROCHURE2016

HOT BOX

A

B

NOTE: Install unit and flue prior to plastering.

NOTE: Plaster is to finishflush with thefascia as shown.

Floor leve

Fascia

Mantel

Stud

Firebox

l frame out.

Ensure unit ispositioned atfinished hearthheight.

Fascia

Firebox

Plaster

Stud

I

Firebox

J

K

Hearth

FlueJ

Clearance to CombustiblesPLAN

FRONTLHS

HG

F

D

E

E

A B C D E F G H NG Mj/h

LP Mj/h

GPO REQ’D VENTILATIONI J K

26 23 NO 18000mm2920 915 425 700 460 305 150 200 25 100 25CAST FASCIA

C

Fire

A

B

NOTE: Install unit and flue prior to plastering.

NOTE: Plaster to run beyond studs and behind fascia

Floor leve

Fascia

Mantel

Stud

Firebox

l frame out.

Ensure unit ispositioned atfinished hearthheight.

Fascia

Firebox

Plaster

Stud

I

Firebox

J

K

Hearth

FlueJ

Clearance to CombustiblesPLAN

FRONTLHS

HG

F

D

E

E

A B C D E F G H NG Mj/h

LP Mj/h

GPO REQ’D VENTILATIONI J K

26 23 NO 18000mm2920 915 425 700 460 305 150 200 25 100 25CAST FASCIA

C

Fire

A

PLAN

FRONTLHS

PLAN

FRONTLHSFRONTLHS

D D D

E

F L

M D

F

E

L

M

A

C

B

PLAN

F

E

E

F

A B C D E F NG Mj/h

LP Mj/h

GPO REQ’D VENTILATION

570HOT BOX * 230580 465 240 26 265 NO 40000mm2460

L M

--

28 28 YESPYROTECH DELUXE 610 610 370 600 360 NOT REQUIRED600 635865

PYROTECH STANDARD 610 610 370 600 360 28 28 YES NOT REQUIRED600 635865

610 620 380 605 370

610 720 380 605 370

610 870 380 605 370

610 1020 380 605

610

710

860

1005 370

670

670

670

740

840

990

1140 670

37 31 YES 40000mm2

37 31 YES 40000mm2

39 36 YES 40000mm2

39 36 YES 40000mm2

HEATSEEKER 600

HEATSEEKER 700

HEATSEEKER 850

HEATSEEKER 1000

*needs a cast fascia Refer to TRIMS section for 4 sided trim dimensions

Hot Box Pyrotech Heatseeker

A B C D E F NG Mj/h

LP Mj/h

GPO REQ’D VENTILATION

570HOT BOX * 230580 465 240 26 23 NO 40000mm2460

L M

--

28 28 YESPYROTECH DELUXE 610 610 370 600 360 NOT REQUIRED600 635865

PYROTECH STANDARD 610 610 370 600 360 28 28 YES NOT REQUIRED600 635865

610 620 380 605 370610 720 380 605 370610 870 380 605 370

610710860

670670670

740840990

37 31 YES 40000mm2

37 31 YES 40000mm2

39 36 YES 40000mm2

HEATSEEKER 600

HEATSEEKER 700

HEATSEEKER 850

*needs a cast fascia Refer to TRIMS section for 4 sided trim dimensions

610 1020 380 605 1005 370 1140 670 39 36 YES 40000mm2HEATSEEKER 1000

A B C D E F NG Mj/h

LP Mj/h

GPO REQ’D VENTILATION

570HOT BOX * 230580 465 240 26 23 NO 40000mm2460

L M

--

28 28 YESPYROTECH DELUXE 610 610 370 600 360 NOT REQUIRED600 635865

PYROTECH STANDARD 610 610 370 600 360 28 28 YES NOT REQUIRED600 635865

610 620 380 605 370610 720 380 605 370610 870 380 605 370

610710860

670670670

740840990

37 31 YES 40000mm2

37 31 YES 40000mm2

39 36 YES 40000mm2

HEATSEEKER 600

HEATSEEKER 700

HEATSEEKER 850

*needs a cast fascia Refer to TRIMS section for 4 sided trim dimensions

610 1020 380 605 1005 370 1140 670 39 36 YES 40000mm2HEATSEEKER 1000

Page 2: E G H HOT BOX I Stud E J BROCHURE H Stud G 2016 · 2016. 12. 6. · Osborne Park W A 47- 5 3 McDonald Street T 08 94 44 9900 Fy shw ick ACT 88 W o llongon g Str eet T 02 62 80 5522

www.realflame.com.au2016 Real Flame Hot Box Brochure

Old world

Natural gas or LPG

Radiant heat up to 20m2

Conventional or Power flue

New or existing applications

Conceived, designed, researched, developed and built in Australia

Whether you’re creating a new fireplace or updating an existing fireplace, you’ll love Real Flame’s Hot Box system. Enjoy all the warmth and romance of a traditional open fire without the mess of a solid fuel fire. Hot Box is available with a number of cast fascia and mantle options to add a touch of classic style.

OLD WORLD, CLASSIC STYLE

HOT BOX