e-001 rad projects... · #fg1 toggle, 2p, manual motor starter ... security system key pad fire...

8
DESCRIPTION SPEAKER, MOUNT @ 12' A.F.F. MINIMUM BRACKET MOUNTED PUBLIC ADDRESS IONIZATION SMOKE DETECTOR FIRE ALARM CONTROL PANEL DUCT SMOKE DETECTOR THERMAL DETECTOR JACK - CANNON TYPE WALL MOUNTED MICROPHONE RECESSED FLOOR MOUNTED MICROPHONE JACK-CANNON TYPE RECESSED CEILING MOUNTED PUBLIC ADDRESS SPEAKER ABBREVIATIONS NORMALLY OPEN CONTACT WEATHERPROOF SWITCH 2x2 OR 2x4 LAY-IN CEILING FLUORESCENT LIGHT FIXTURE a=SWITCH CONTROLLING FIXTURE WALL MOUNTED FLUORESCENT b=SWITCH CONTROLLING FIXTURE FLUORESCENT LIGHT FIXTURE 2x2 OR 2x4 SURFACE MOUNTED UNDER COUNTER OR CEILING FLUORESCENT STRIP LIGHT, SIZE & TYPE AS NOTED 2x2 OR 2x4 RECESSED MOUNTED H.I.D. OR INCANDESCENT FIXTURE TOGGLE, 1P, MANUAL MOTOR STARTER W/THERMAL O.L. RELAY SIZED FOR 115% OF MOTOR RUNNING AMPS IN NEMA 1 ENCLOSURE EQUAL TO SQ'D' CLASS 2510, #FG1 TOGGLE, 2P, MANUAL MOTOR STARTER W/THERMAL O.L. RELAY SIZED FOR 115% OF MOTOR RUNNING AMPS IN NEMA 1 ENCLOSURE EQUAL TO SQ'D' CLASS 2510, #FG2 FIXTURE Ab Aa A=FIXTURE TYPE A=FIXTURE TYPE 2M M WP PEC 3 4 THREE-WAY SWITCH FOUR-WAY SWITCH PHOTO ELECTRIC CELL AS NOTED ON DRAWING AS NOTED ON DRAWING SERVICE METER & DISCONNECT(S) M T TRANSFORMER DISCONNECT SWITCH PANEL BOARD SECURITY SYSTEM KEY PAD FIRE ALARM ADA STROBE KEYED NOTE DESIGNATION FLUSH MOUNTED VOICE OUTLET, 4" SQUARE BOX WITH SINGLE GANG BLANK FACE PLATE. INSTALL MINIMUM 3/4" CONDUIT WITH PULL WIRE TO TELCOM ROOM FLUSH MOUNTED DATA OUTLET, 4" SQUARE BOX WITH SINGLE GANG BLANK FACE PLATE. INSTALL MINIMUM 3/4" CONDUIT WITH PULL WIRE TO ABOVE CEILING TC C TIME CLOCK RELAY COIL OR K V T 1 MOUNT @ 80" A.F.F. THERMOSTAT CONNECTION FLOOR RECEPTACLE OR AS NOTED ON DRAWING CONTROL OF PARTICULAR DEVICE USE SUBSCRIPT TO DESIGNATE DOUBLE POLE SWITCH (DPST) GROUND FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET WITH WEATHERPROOF NEW CONDUIT OR CABLE GROUNDING CONDUCTOR DUPLEX RECEPTACLE OUTLET EXISTING CONDUIT OR CABLE DOUBLE DUPLEX RECEPTACLE OUTLET RECEPTACLE AS NOTED ON DRAWINGS HALF-SWITCHED OR SPLIT-WIRED 3 - DENOTES CIRCUIT NUMBER GFCI D 2 a WP SINGLE POLE SWITCH - DIMMER WALL SWITCH COVER 3 G DRYER OUTLET, 30A-2P RECEPTACLE JUNCTION BOX WALL JUNCTION BOX SYMBOL CONDUIT CAP BURIED CONDUIT HOMERUN CONDUIT DESCRIPTION LIGHT POLE WITH FIXTURE FIRE ALARM HORN & ADA STROBE, FRAME FUSIBLE DISCONNECT SWITCH NORMALLY CLOSED CONTACT 300AT 400AF S FUSIBLE ELEMENT GROUND WALL SPEAKER CIRCUIT BREAKER FUSE 3P S H V OR OR MOUNT @ 80" A.F.F. CEILING SPEAKER HEAT DETECTOR EXIT SIGN TRIP M M B M S M DOOR BELL PUSH BUTTON METER MOTOR (ALL SYMBOLS MAY NOT BE USED) SYMBOLS LEGEND WALL MOUNTED LIGHT FIXTURE SURFACE MOUNTED LIGHT FIXTURE SYMBOL DESCRIPTION FACP SYMBOL DD S I T (PHOTOELECTRIC) EMERGENCY LIGHTING OR WALL CEILING EMS (EMERGENCY/EXIT LIGHTING) OR CABLE TV/SATELLITE JACKS INSTALL MINIMUM 3/4" CONDUIT WITH PULL WIRE TO ABOVE CEILING SD SMOKE/HEAT DETECTOR (APPLICABLE TO ALL ELECTRICAL SHEETS) General Notes A. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL ELECTRICAL SYSTEMS IN ACCORDANCE WITH THE PLANS AND ASSOCIATED NOTES, IN ACCORDANCE WITH LATEST NATIONAL ELECTRICAL CODE, STATE AND LOCAL CODES, UTILITY AUTHORITY STANDARDS, AND IN A WORKMAN LIKE MANNER. B. THE ELECTRICAL CONTRACTOR SHALL MAKE REQUIRED CONNECTIONS TO EQUIPMENT FURNISHED BY OTHERS. C. THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN HIS BID THE COSTS OF ALL PERMITS, TESTS AND INSPECTIONS, AND VISIT THE SITE OF WORK PRIOR TO SUBMITTING BID. D. THE ELECTRICAL CONTRACTOR SHALL COORDINATE HIS WORK WITH THE OTHER TRADES AND REFER TO ARCHITECTURAL, MECHANICAL AND STRUCTURAL PLANS TO DETERMINE THE EXACT LOCATION OF EQUIPMENT. E. A SET OF MARKED UP PRINTS SHALL BE PREPARED SHOWING ALL CHANGES MADE DURING CONSTRUCTION AND TURNED OVER TO THE ENGINEER AT THE END OF THE JOB. ALL CHANGES MUST HAVE THE ENGINEER'S APPROVAL. F. ANY DISCREPANCY BETWEEN MATERIAL DESCRIPTION AND CATALOG NUMBER SHALL BE BROUGHT TO THE ENGINEERS ATTENTION IMMEDIATELY. G. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM ENGINEER FOR ALL SUBSTITUTIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SUBSTITUTIONS. H. ALL CONDUCTORS SHALL BE #12 SOLID COPPER, TYPE THHN/THHW OR EQUIVALENT, UNLESS OTHERWISE NOTED. 120V BRANCH CIRCUIT RUNS WHICH EXCEED 100 FT IN LENGTH SHALL BE #10 THHN/THHW OR EQUIVALENT. I. THE SAME COLOR CODING SHALL BE MAINTAINED THROUGHOUT ALL CIRCUITS. J. ALL REQUIRED CONDUITS SHALL BE INSTALLED IN A NEAT AND WORKMAN LIKE MANNER. CONDUITS SHALL BE RUN PARALLEL AND PERPENDICULAR TO BUILDING LINES. K. ALL PULL BOXES AND JUNCTION BOXES SHALL BE CODE GA. AND MEET THE MINIMUM SIZE AS RECOMMENDED BY THE NEC. L. RECEPTACLES AND SWITCHES SERVING MECHANICAL EQUIPMENT/MOTOR LOADS SHALL BE HORSEPOWER RATED. M. THE ELECTRICAL CONTRACTOR SHALL SEAL ALL PENETRATIONS THROUGH WALLS, CEILINGS AND FLOORS CAUSED BY THE INSTALLATION OF ELECTRICAL SYSTEMS TO RESTORE THE FIRE RATING AND MAKE WEATHER TIGHT AS REQUIRED. N. ALL CONDUIT SHALL BE CONCEALED IN WALLS, CEILING OR FLOOR UNLESS OTHERWISE NOTED. O. CONTRACTOR SHALL INCLUDE IN HIS PRICE ALL COSTS ASSOCIATED WITH GETTING POWER/TELEPHONE SERVICE TO THE SITE. P. THESE PLANS ARE NOT INTENDED TO BRING EXISTING FACILITIES UP TO ELECTRICAL CODE COMPLIANCE. Q. CONTRACTOR SHALL COORDINATE WITH OWNER, TELECOMMUNICATIONS UTILITY COMPANY, AND CABLE SERVICE PROVIDER FOR INSTALLATION OF LINES DURING CONSTRUCTION. R. COORDINATE NEW SERVICE WITH LOCAL UTILITY AND COMPLY WITH ALL APPLICABLE LOCAL UTILITY STANDARDS. S. MOUNT RECEPTACLES MINIMUM 15" A.F.F. MOUNT LIGHT SWITCHES 42" A.F.F. ENSURE ALL RECEPTACLES AND SWITCHES ARE ACCESSIBLE AT CASE WORK. MOUNT RECEPTACLES NOT MORE THAN 20" ABOVE COUNTERS. T. VERIFY EXACT LOCATION OF ALL ELECTRIC EQUIPMENT AND FIXTURES WITH ARCHITECTURAL AND MECHANICAL DRAWINGS. U. PROPERLY SEAL ALL PENETRATIONS THROUGH WALLS, FLOORS, CEILING AND ROOF IN ACCORDANCE WITH THE LOCAL CODE, AHJ AND OWNER REQUIREMENTS. FIRE STOP ALL RATED PENETRATIONS.. V. VERIFY LOCATION OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO TRENCHING. BACKFILL, COMPACT, AND RESTORE SURFACE TO EXISTING. W. MULTI-WIRE BRANCH CIRCUIT NOT PERMITTED. X. NO HORIZONTAL CONDUIT RUNS ON ROOF. Y. CONDUCTORS IN UNDERGROUND CONDUITS MUST BE THW OR THWN (CONSIDERS WET LOCATION BY NEC). ABBREVIATIONS AFCI ARC FAULT CIRCUIT INTERRUPTER GFI NATIONAL ELECTRICAL MANUFACTURER'S GALVANIZED RIGID STEEL CONDUIT MAIN DISTRIBUTION PANEL ELECTRICAL METALLIC TUBING WEATHERPROOF PER NEC 2011 406.9(B) UNLESS NOTED OTHERWISE TELEPHONE BACK BOARD DEVICE MOUNTING HEIGHT ABOVE FINISHED FLOOR CIRCUIT CCT, CKT NL UNO XFMR WP TYP. TBB NIGHT LIGHT TRANSFORMER TYPICAL RECPT, REC(S) RM. O/C PNL PEC MCB NO. NEMA MDP OVERCURRENT PANELBOARD RECEPTACLE(S) PHOTO ELECTRICAL CELL ROOM ASSOCIATION MAIN CIRCUIT BREAKER NUMBER HR MCB MLO GDO GRS GND, G EX, EXIST EMT GARAGE DOOR OPENER MAIN CIRCUIT BREAKER MAIN LUGS ONLY HOMERUN GROUND EXISTING C.O. C A.F.F. A.F.G. + 42" A, AMPS ABOVE FINISHED FLOOR ABOVE FINISHED GRADE CONDUIT ONLY CONDUIT AMPERES EMERGENCY LIGHTING EM GROUND FAULT INTERRUPTER UNDER COUNTER UC FIRE ALARM PULL STATION F J J FILE NAME: DATE: SHEET: REVISION: T H O M A S G I F F O R D A R C H I T E C T PO BOX 31934 SANTA FE , NEW MEXICO 87594 PHONE 505.690.5898 FACSIMILE 505.982.7884 EMAIL [email protected] TGA Cerro Gordo 6.17.13 C E R R O G O R D O H O U S I N G C E R R O G O R D O S A N T A F E , N E W M E X I C O NOTES E-001 & LEGENDS JL PD

Upload: trinhque

Post on 22-Apr-2018

222 views

Category:

Documents


4 download

TRANSCRIPT

DESCRIPTION

SPEAKER, MOUNT @ 12' A.F.F. MINIMUMBRACKET MOUNTED PUBLIC ADDRESS

IONIZATION SMOKE DETECTOR

FIRE ALARM CONTROL PANEL

DUCT SMOKE DETECTOR

THERMAL DETECTOR

JACK - CANNON TYPEWALL MOUNTED MICROPHONE

RECESSED FLOOR MOUNTEDMICROPHONE JACK-CANNON TYPE

RECESSED CEILING MOUNTEDPUBLIC ADDRESS SPEAKER

ABBREVIATIONS

NORMALLY OPEN CONTACT

WEATHERPROOF SWITCH

2x2 OR 2x4 LAY-IN CEILINGFLUORESCENT LIGHT FIXTURE

a=SWITCH CONTROLLING FIXTURE

WALL MOUNTED FLUORESCENT

b=SWITCH CONTROLLING FIXTURE

FLUORESCENT LIGHT FIXTURE2x2 OR 2x4 SURFACE MOUNTED

UNDER COUNTER OR CEILING FLUORESCENTSTRIP LIGHT, SIZE & TYPE AS NOTED

2x2 OR 2x4 RECESSED MOUNTED H.I.D. ORINCANDESCENT FIXTURE

TOGGLE, 1P, MANUAL MOTOR STARTERW/THERMAL O.L. RELAY SIZED FOR 115% OFMOTOR RUNNING AMPS IN NEMA 1ENCLOSURE EQUAL TO SQ'D' CLASS 2510,#FG1

TOGGLE, 2P, MANUAL MOTOR STARTERW/THERMAL O.L. RELAY SIZED FOR 115% OFMOTOR RUNNING AMPS IN NEMA 1ENCLOSURE EQUAL TO SQ'D' CLASS 2510,#FG2

FIXTURE

Ab

Aa

A=FIXTURE TYPE

A=FIXTURE TYPE

2M

M

WP

PEC

3

4

THREE-WAY SWITCH

FOUR-WAY SWITCH

PHOTO ELECTRIC CELL

AS NOTED ON DRAWING

AS NOTED ON DRAWING

SERVICE METER & DISCONNECT(S)M

T TRANSFORMER

DISCONNECT SWITCH

PANEL BOARD

SECURITY SYSTEM KEY PAD

FIRE ALARM ADA STROBE

KEYED NOTE DESIGNATION

FLUSH MOUNTED VOICE OUTLET, 4"SQUARE BOX WITH SINGLE GANGBLANK FACE PLATE. INSTALL MINIMUM3/4" CONDUIT WITH PULL WIRE TOTELCOM ROOM

FLUSH MOUNTED DATA OUTLET, 4"SQUARE BOX WITH SINGLE GANGBLANK FACE PLATE. INSTALL MINIMUM3/4" CONDUIT WITH PULL WIRE TOABOVE CEILING

TC

C

TIME CLOCK

RELAY COIL

OR

K

V

T

1

MOUNT @ 80" A.F.F.

THERMOSTAT

CONNECTION

FLOOR RECEPTACLE OR AS NOTED ONDRAWING

CONTROL OF PARTICULAR DEVICEUSE SUBSCRIPT TO DESIGNATE

DOUBLE POLE SWITCH (DPST)

GROUND FAULT CIRCUIT INTERRUPTERDUPLEX OUTLET WITH WEATHERPROOF

NEW CONDUIT OR CABLE

GROUNDING CONDUCTOR

DUPLEX RECEPTACLE OUTLET

EXISTING CONDUIT OR CABLE

DOUBLE DUPLEX RECEPTACLE OUTLET

RECEPTACLE AS NOTED ON DRAWINGS

HALF-SWITCHED OR SPLIT-WIRED

3 - DENOTES CIRCUIT NUMBER

GFCI

D

2

a

WP

SINGLE POLE SWITCH -

DIMMER WALL SWITCH

COVER

3

G

DRYER OUTLET, 30A-2P

RECEPTACLE

JUNCTION BOX

WALL JUNCTION BOX

SYMBOL

CONDUIT CAP

BURIED CONDUIT

HOMERUN CONDUIT

DESCRIPTION

LIGHT POLE WITH FIXTURE

FIRE ALARM HORN & ADA STROBE,

FRAME

FUSIBLE DISCONNECT SWITCH

NORMALLY CLOSED CONTACT

300AT400AF

S

FUSIBLE ELEMENT

GROUND

WALL SPEAKER

CIRCUIT BREAKER

FUSE

3P

S

H

V

OR

OR

MOUNT @ 80" A.F.F.

CEILING SPEAKER

HEAT DETECTOR

EXIT SIGN

TRIP

M

M

B

M

S

M

DOOR BELL

PUSH BUTTON

METER

MOTOR

(ALL SYMBOLS MAY NOT BE USED)SYMBOLS LEGEND

WALL MOUNTED LIGHT FIXTURE

SURFACE MOUNTED LIGHT FIXTURE

SYMBOL DESCRIPTION

FACP

SYMBOL

DD

S

I

T

(PHOTOELECTRIC)

EMERGENCY LIGHTINGORWALL

CEILING

EMS (EMERGENCY/EXIT LIGHTING)

OR

CABLE TV/SATELLITE JACKS INSTALLMINIMUM 3/4" CONDUIT WITH PULLWIRE TO ABOVE CEILING

SDSMOKE/HEAT DETECTOR

(APPLICABLE TO ALL ELECTRICAL SHEETS)General Notes

A. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL ELECTRICALSYSTEMS IN ACCORDANCE WITH THE PLANS AND ASSOCIATED NOTES, INACCORDANCE WITH LATEST NATIONAL ELECTRICAL CODE, STATE AND LOCALCODES, UTILITY AUTHORITY STANDARDS, AND IN A WORKMAN LIKE MANNER.

B. THE ELECTRICAL CONTRACTOR SHALL MAKE REQUIRED CONNECTIONS TOEQUIPMENT FURNISHED BY OTHERS.

C. THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN HIS BID THE COSTS OF ALLPERMITS, TESTS AND INSPECTIONS, AND VISIT THE SITE OF WORK PRIOR TOSUBMITTING BID.

D. THE ELECTRICAL CONTRACTOR SHALL COORDINATE HIS WORK WITH THE OTHERTRADES AND REFER TO ARCHITECTURAL, MECHANICAL AND STRUCTURAL PLANSTO DETERMINE THE EXACT LOCATION OF EQUIPMENT.

E. A SET OF MARKED UP PRINTS SHALL BE PREPARED SHOWING ALL CHANGESMADE DURING CONSTRUCTION AND TURNED OVER TO THE ENGINEER AT THEEND OF THE JOB. ALL CHANGES MUST HAVE THE ENGINEER'S APPROVAL.

F. ANY DISCREPANCY BETWEEN MATERIAL DESCRIPTION AND CATALOG NUMBERSHALL BE BROUGHT TO THE ENGINEERS ATTENTION IMMEDIATELY.

G. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM ENGINEER FOR ALLSUBSTITUTIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALLSUBSTITUTIONS.

H. ALL CONDUCTORS SHALL BE #12 SOLID COPPER, TYPE THHN/THHW OREQUIVALENT, UNLESS OTHERWISE NOTED. 120V BRANCH CIRCUIT RUNS WHICHEXCEED 100 FT IN LENGTH SHALL BE #10 THHN/THHW OR EQUIVALENT.

I. THE SAME COLOR CODING SHALL BE MAINTAINED THROUGHOUT ALL CIRCUITS.

J. ALL REQUIRED CONDUITS SHALL BE INSTALLED IN A NEAT AND WORKMAN LIKEMANNER. CONDUITS SHALL BE RUN PARALLEL AND PERPENDICULAR TOBUILDING LINES.

K. ALL PULL BOXES AND JUNCTION BOXES SHALL BE CODE GA. AND MEET THEMINIMUM SIZE AS RECOMMENDED BY THE NEC.

L. RECEPTACLES AND SWITCHES SERVING MECHANICAL EQUIPMENT/MOTORLOADS SHALL BE HORSEPOWER RATED.

M. THE ELECTRICAL CONTRACTOR SHALL SEAL ALL PENETRATIONS THROUGHWALLS, CEILINGS AND FLOORS CAUSED BY THE INSTALLATION OF ELECTRICALSYSTEMS TO RESTORE THE FIRE RATING AND MAKE WEATHER TIGHT ASREQUIRED.

N. ALL CONDUIT SHALL BE CONCEALED IN WALLS, CEILING OR FLOOR UNLESSOTHERWISE NOTED.

O. CONTRACTOR SHALL INCLUDE IN HIS PRICE ALL COSTS ASSOCIATED WITHGETTING POWER/TELEPHONE SERVICE TO THE SITE.

P. THESE PLANS ARE NOT INTENDED TO BRING EXISTING FACILITIES UP TOELECTRICAL CODE COMPLIANCE.

Q. CONTRACTOR SHALL COORDINATE WITH OWNER, TELECOMMUNICATIONSUTILITY COMPANY, AND CABLE SERVICE PROVIDER FOR INSTALLATION OF LINESDURING CONSTRUCTION.

R. COORDINATE NEW SERVICE WITH LOCAL UTILITY AND COMPLY WITH ALLAPPLICABLE LOCAL UTILITY STANDARDS.

S. MOUNT RECEPTACLES MINIMUM 15" A.F.F. MOUNT LIGHT SWITCHES 42" A.F.F.ENSURE ALL RECEPTACLES AND SWITCHES ARE ACCESSIBLE AT CASE WORK.MOUNT RECEPTACLES NOT MORE THAN 20" ABOVE COUNTERS.

T. VERIFY EXACT LOCATION OF ALL ELECTRIC EQUIPMENT AND FIXTURES WITHARCHITECTURAL AND MECHANICAL DRAWINGS.

U. PROPERLY SEAL ALL PENETRATIONS THROUGH WALLS, FLOORS, CEILING ANDROOF IN ACCORDANCE WITH THE LOCAL CODE, AHJ AND OWNERREQUIREMENTS. FIRE STOP ALL RATED PENETRATIONS..

V. VERIFY LOCATION OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TOTRENCHING. BACKFILL, COMPACT, AND RESTORE SURFACE TO EXISTING.

W. MULTI-WIRE BRANCH CIRCUIT NOT PERMITTED.

X. NO HORIZONTAL CONDUIT RUNS ON ROOF.

Y. CONDUCTORS IN UNDERGROUND CONDUITS MUST BE THW OR THWN(CONSIDERS WET LOCATION BY NEC).

ABBREVIATIONS

AFCI ARC FAULT CIRCUIT INTERRUPTER

GFI

NATIONAL ELECTRICAL MANUFACTURER'S

GALVANIZED RIGID STEEL CONDUIT

MAIN DISTRIBUTION PANEL

ELECTRICAL METALLIC TUBING

WEATHERPROOF PER NEC 2011 406.9(B)

UNLESS NOTED OTHERWISE

TELEPHONE BACK BOARD

DEVICE MOUNTING HEIGHT ABOVE FINISHED FLOOR

CIRCUITCCT, CKT

NL

UNO

XFMR

WP

TYP.

TBB

NIGHT LIGHT

TRANSFORMER

TYPICAL

RECPT, REC(S)

RM.

O/C

PNL

PEC

MCB

NO.

NEMA

MDP

OVERCURRENT

PANELBOARD

RECEPTACLE(S)

PHOTO ELECTRICAL CELL

ROOM

ASSOCIATION

MAIN CIRCUIT BREAKER

NUMBER

HR

MCB

MLO

GDO

GRS

GND, G

EX, EXIST

EMT

GARAGE DOOR OPENER

MAIN CIRCUIT BREAKER

MAIN LUGS ONLY

HOMERUN

GROUND

EXISTING

C.O.

C

A.F.F.

A.F.G.

+ 42"

A, AMPS

ABOVE FINISHED FLOOR

ABOVE FINISHED GRADE

CONDUIT ONLY

CONDUIT

AMPERES

EMERGENCY LIGHTINGEM

GROUND FAULT INTERRUPTER

UNDER COUNTERUC

FIRE ALARM PULL STATIONF

J

J

FILE

NAM

E:

DATE

:

SHEET:

REVI

SION

:T

H O

M A

S G

I F F

O R

D A

R C

H I T

E C

TPO

BOX

319

34 S

ANTA

FE

, NEW

MEX

ICO

8759

4 P

HONE

505.6

90.58

98 F

ACSI

MILE

505.9

82.78

84 E

MAIL

THOM

ASGI

FFOR

D@CO

MCAS

T.NE

T

TGA

Cerro

Gor

do

6.17.1

3

C E

R R

O G

O R

D O

H O

U S

I N G

C E

R R

O G

O R

D O

S

A N

T A

F E

, N

E W

M E

X I C

O

NOTES

E-001

&LEGENDS

JLPD

DB

LP-20,22

LP-9

1

1

1

1

14

LP-21

LP-13,15

WH-1

3

3

3

3

WPGFI7

5

5 5

5

7WPGFI

9GFIAC

LP-17,19

6

21

TYP

21

TYP

21

TYP

3TYP

4

4 4

13 8

7

9

10

FC-2

23

GFI2

4GFI

~

TO LIGHTSWITCH

3

86

LP-24,26

11

1

1

HP-2

LP-16,18

12 13

13

5Ac

Ad

Ab

Ba

Ah

Ag

Ae

Bf

9

~

TO FAN SWITCH

AmAk

Ac

Am

Am

Am

Ad

Ak

An

Ap

Aj Aj

Dr

Dr

FILE

NAM

E:

DATE

:

SHEET:

REVI

SION

:T

H O

M A

S G

I F F

O R

D A

R C

H I T

E C

TPO

BOX

319

34 S

ANTA

FE

, NEW

MEX

ICO

8759

4 P

HONE

505.6

90.58

98 F

ACSI

MILE

505.9

82.78

84 E

MAIL

THOM

ASGI

FFOR

D@CO

MCAS

T.NE

T

TGA

Cerro

Gor

do

6.17.1

3

C E

R R

O G

O R

D O

H O

U S

I N G

C E

R R

O G

O R

D O

S

A N

T A

F E

, N

E W

M E

X I C

O

Scale: 1/4" = 1'-0"

1

EXISTING C-2

E-101

PLANS -ELECTRICAL

JLPD

1/4" = 1'-0"

1 4 80 2 12

General Notes

Keyed Notes

1. ALL 15A & 20A/125V RECEPTACLES(INTERIOR/EXTIRIOR) TO BE TAMPER RESISTANTPER 2011 NEC ARTICLE 406.12.

2. IN THIS AREA RECEPTACLES TO BE AFCIPROTECTED PER 2011 NEC ARTICLE 210-12.

3. LOCATE RECEPTACLE 6 INCHES ABOVECOUNTER TOPS, GFI, TYPICAL.

4. DOOR PUSH BUTTON, BELL & TRANSFORMER.MOUNT PUSH BUTTON 48" A.F.F., MOUNTTRANSFORMER IN CLOSET. RUN #18 SOLIDCONDUCTOR, TWISTED PAIR, JACKETED CABLEFROM TRANSFORMER TO BELL & PUSH BUTTON.

5. PROVIDE 30A, 240V RECEPTACLE OR SAFETYSWITCH FOR WATER HEATER, MATCHEQUIPMENT SUPPLIED.

6. PROVIDE 50A, 240V-1PH DRYER OUTLET. MATCHEQUIPMENT SELECTED. RUN 3#8 CU., (IFNEUTRAL IS REQUIRED) AND 1#10 CU. EGC TOPANEL.

7. STUB-OUT 12/2 WITH GROUND, NON METALLICSHEATHING CABLE FOR RANGE HOOD. VERIFYHEIGHT W/EQUIPMENT. PROVIDE CONTROLS 48"A.F.F. NEXT TO, BUT NOT ABOVE, COOKTOP.

8. PROVIDE HALF-SWITCHED RECEPTACLE FORDISPOSER. LOCATE SWITCH IN ACCORDANCEWITH 2011 NEC.

9. WIRE EXHAUST FAN WITH LIGHT CIRCUIT.SWITCH SEPARATELY.

10. PROVIDE 50A, 240V-1PH RANGE OUTLET. MATCHEQUIPMENT SELECTED. RUN 3#8 CU., (IFNEUTRAL IS REQUIRED) AND 1#10 CU. EGC TOPANEL.

11. REPLACE EXISTING PANEL/LOAD CENTER WITHNEW, AT SAME LOCATION. COORDINATELOCATION WITH OWNER/ARCHITECT, OBSERVENEC CLEARANCE AND CODE REQUIREMENTS.

12. PROVIDE 30A, 230V-1PH SAFETY SWITCH FORHP-2. FIELD COORDINATE EXACT LOCATION.

13. RUN 3#10 CU., (IF NEUTRAL IS REQUIRED) AND1#10 CU. EGC TO PANEL.

POWER PLAN - EXISTING

TWO BEDROOM UNIT C-2

Scale: 1/4" = 1'-0"

2

LIGHTING PLAN - EXISTING

TWO BEDROOM UNIT C-2

MIR

RO

R L

INE

MIR

RO

R L

INEPOWER IS THE SAME FOR

MIRRORED FLOOR PLANLIGHTING IS THE SAME FORMIRRORED FLOOR PLAN

DB

LP-20,22

LP-9

11

1

14

LP-21

LP-13,15

WH-1

WPGFI25

25WPGFI

9GFIAC

LP-17,19

6

21

TYP21

TYP

21

TYP3

TYP

4

4

4

5

8

7

9

10

FC-2

23

2GFI

4

~

TO LIGHTSWITCH

33

3

1

3

55

5

5

7

7

7

7

21

TYP

7

8 6

LP-24,26

11

1

1

HP-2

LP-16,18

12 13

13

13

Ba

Ah

Ag

Ab

Ae

Bf

9

~

TO FAN SWITCH

Ak

Ak

Ak

Ak

Ad

Ac

Ad

Ac

Am Am Aj Aj

Ap Ap

Ar

As

Dt

Dt

FILE

NAM

E:

DATE

:

SHEET:

REVI

SION

:T

H O

M A

S G

I F F

O R

D A

R C

H I T

E C

TPO

BOX

319

34 S

ANTA

FE

, NEW

MEX

ICO

8759

4 P

HONE

505.6

90.58

98 F

ACSI

MILE

505.9

82.78

84 E

MAIL

THOM

ASGI

FFOR

D@CO

MCAS

T.NE

T

TGA

Cerro

Gor

do

6.17.1

3

C E

R R

O G

O R

D O

H O

U S

I N G

C E

R R

O G

O R

D O

S

A N

T A

F E

, N

E W

M E

X I C

O

EXISTING C-3

E-102

PLANS -ELECTRICAL

JLPD

1/4" = 1'-0"

1 4 80 2 12

General Notes

Keyed Notes

1. ALL 15A & 20A/125V RECEPTACLES(INTERIOR/EXTERIOR) TO BE TAMPER RESISTANTPER 2011 NEC ARTICLE 406.12.

2. IN THIS AREA RECEPTACLES TO BE AFCIPROTECTED PER 2011 NEC ARTICLE 210-12.

3. LOCATE RECEPTACLE 6 INCHES ABOVECOUNTER TOPS, GFI TYPICAL.

4. DOOR PUSH BUTTON, BELL & TRANSFORMER.MOUNT PUSH BUTTON 48" A.F.F., MOUNTTRANSFORMER IN CLOSET. RUN #18 SOLIDCONDUCTOR, TWISTED PAIR, JACKETED CABLEFROM TRANSFORMER TO BELL & PUSH BUTTON.

5. PROVIDE 30A, 240V RECEPTACLE OR SAFETYSWITCH FOR WATER HEATER, MATCHEQUIPMENT SUPPLIED.

6. PROVIDE 50A, 240V-1PH DRYER OUTLET. MATCHEQUIPMENT SELECTED. RUN 3#8 CU., (IFNEUTRAL IS REQUIRED) AND 1#10 CU. EGC TOPANEL.

7. STUB-OUT 12/2 WITH GROUND, NON METALLICSHEATHING CABLE FOR RANGE HOOD. VERIFYHEIGHT W/EQUIPMENT. PROVIDE CONTROLS 48"A.F.F. NEXT TO, BUT NOT ABOVE, COOKTOP.

8. PROVIDE HALF-SWITCHED RECEPTACLE FORDISPOSER. LOCATE SWITCH IN ACCORDANCEWITH 2011 NEC.

9. WIRE EXHAUST FAN WITH LIGHT CIRCUIT.SWITCH SEPARATELY.

10. PROVIDE 50A, 240V-1PH RANGE OUTLET. MATCHEQUIPMENT SELECTED. RUN 3#8 CU., (IFNEUTRAL IS REQUIRED) AND 1#10 CU. EGC TOPANEL.

11. REPLACE EXISTING PANEL/LOAD CENTER WITHNEW, AT SAME LOCATION. COORDINATELOCATION WITH OWNER/ARCHITECT, OBSERVENEC CLEARANCE AND CODE REQUIREMENTS.

12. PROVIDE 30A, 230V-1PH SAFETY SWITCH FORHP-2. FIELD COORDINATE EXACT LOCATION.

13. RUN 3#10 CU., (IF NEUTRAL IS REQUIRED) AND1#10 CU. EGC TO PANEL.

Scale: 1/4" = 1'-0"

1

POWER PLAN - EXISTING

THREE BEDROOM UNIT C-3

Scale: 1/4" = 1'-0"

2

LIGHTING PLAN - EXISTING

THREE BEDROOM UNIT C-3

GFI

DB

LP-20,22LP-9

1

11

1

14

LP-21 4

LP-13,15

WH-1

3

3

3

3

WPGFI7

5

55

5

7WPGFI

GFI9

LP-17,19

FC-2

2

6

21

TYP

21

TYP

21

TYP

3TYP

44

4

5

8

7

9

10

6

23

~

TO LIGHTSWITCH

3

6LP-24,26

12 12

1

1

13

LP-25

HP-2LP-16,18

1514 15

15

AbBa

Ag

Ah

An

Ak

Am

Am

Bf

9

~

TO FANSWITCH

Ar Ar

Ae

Ae

Ae

Ae

Ad

Ad

Ac

Ac

Ap

Dr

Dr

Aj Aj

FILE

NAM

E:

DATE

:

SHEET:

REVI

SION

:T

H O

M A

S G

I F F

O R

D A

R C

H I T

E C

TPO

BOX

319

34 S

ANTA

FE

, NEW

MEX

ICO

8759

4 P

HONE

505.6

90.58

98 F

ACSI

MILE

505.9

82.78

84 E

MAIL

THOM

ASGI

FFOR

D@CO

MCAS

T.NE

T

TGA

Cerro

Gor

do

6.17.1

3

C E

R R

O G

O R

D O

H O

U S

I N G

C E

R R

O G

O R

D O

S

A N

T A

F E

, N

E W

M E

X I C

O

NEW C-A

E-103

PLANS -ELECTRICAL

JLPD

1/4" = 1'-0"

1 4 80 2 12

General Notes

Keyed Notes

1. ALL 15A & 20A/125V RECEPTACLES(INTERIOR/EXTERIOR) TO BE TAMPER RESISTANTPER 2011 NEC ARTICLE 406.12.

2. IN THIS AREA RECEPTACLES TO BE AFCIPROTECTED PER 2011 NEC ARTICLE 210-12.

3. LOCATE RECEPTACLE 6 INCHES ABOVECOUNTER TOPS, GFI TYPICAL.

4. DOOR PUSH BUTTON, BELL & TRANSFORMER.MOUNT PUSH BUTTON 48" A.F.F., MOUNTTRANSFORMER IN CLOSET. RUN #18 SOLIDCONDUCTOR, TWISTED PAIR, JACKETED CABLEFROM TRANSFORMER TO BELL & PUSH BUTTON.

5. PROVIDE 30A, 240V RECEPTACLE OR SAFETYSWITCH FOR WATER HEATER, MATCHEQUIPMENT SUPPLIED.

6. PROVIDE 50A, 240V-1PH DRYER OUTLET. MATCHEQUIPMENT SELECTED. RUN 3#8 CU., (IFNEUTRAL IS REQUIRED) AND 1#10 CU. EGC TOPANEL.

7. STUB-OUT 12/2 WITH GROUND, NON METALLICSHEATHING CABLE FOR RANGE HOOD. VERIFYHEIGHT W/EQUIPMENT. PROVIDE CONTROLS 48"A.F.F. NEXT TO, BUT NOT ABOVE, COOKTOP.

8. PROVIDE HALF-SWITCHED RECEPTACLE FORDISPOSER. LOCATE SWITCH IN ACCORDANCEWITH 2011 NEC.

9. WIRE EXHAUST FAN WITH LIGHT CIRCUIT.SWITCH SEPARATELY.

10. ELECTRIC PANEL SHOWN GRAPHICALLY,COORDINATE LOCATION WITHOWNER/ARCHITECT, OBSERVE NEC CLEARANCEAND CODE REQUIREMENTS.

11. 50A, 240V-1PH RANGE OUTLET. MATCHEQUIPMENT SELECTED. RUN 3#8 CU., (IFNEUTRAL IS REQUIRED) AND 1#10 CU. EGC TOPANEL.

12. PROVIDE 20A, 120V-1PH DUPLEX RECEPTACLEFOR RECIRCULATION PUMP.

13. PROVIDE J-BOX IN CEILING SPACE FOR FUTURERADON FAN (FAN N.I.C.).

14. PROVIDE 30A, 230V-1PH SAFETY SWITCH FORHP-2.

15. RUN 3#10 CU., (IF NEUTRAL IS REQUIRED) AND1#10 CU. EGC TO PANEL.

Scale: 1/4" = 1'-0"

1

POWER PLAN - NEW

TWO BEDROOM UNIT C-A

Scale: 1/4" = 1'-0"

2

LIGHTING PLAN - NEW

TWO BEDROOM UNIT C-A

MIR

RO

R L

INE

MIR

RO

R L

INE

POWER IS THE SAME FORMIRRORED FLOOR PLAN

LIGHTING IS THE SAME FORMIRRORED FLOOR PLAN

LP-14,16

WH-2 2

4

3

3

LP-6,8

4

1

2

LP-9,11

1

2WPGFI

1

1

15 8

HP-1LP-18,20

1110

FC-1

LP-17,19

10

11

EBB-1

LP-5

Ba

A

A

A A A A

EF

A A

A A

LC TS PC

FILE

NAM

E:

DATE

:

SHEET:

REVI

SION

:T

H O

M A

S G

I F F

O R

D A

R C

H I T

E C

TPO

BOX

319

34 S

ANTA

FE

, NEW

MEX

ICO

8759

4 P

HONE

505.6

90.58

98 F

ACSI

MILE

505.9

82.78

84 E

MAIL

THOM

ASGI

FFOR

D@CO

MCAS

T.NE

T

TGA

Cerro

Gor

do

6.17.1

3

C E

R R

O G

O R

D O

H O

U S

I N G

C E

R R

O G

O R

D O

S

A N

T A

F E

, N

E W

M E

X I C

O

NEW C-L

E-104

PLANS -ELECTRICAL

JLPD

1/4" = 1'-0"

1 4 80 2 12

General Notes

Keyed Notes

1. ALL 15A & 20A/125V RECEPTACLES(INTERIOR/EXTERIOR) TO BE TAMPER RESISTANTPER 2011 NEC ARTICLE 406.12.

2. PROVIDE 30A, 240V SAFETY SWITCH FOR WATERHEATER, MATCH EQUIPMENT SUPPLIED.

3. PROVIDE 50A, 240V-1PH DRYER OUTLET. MATCHEQUIPMENT SELECTED. RUN 3#8 CU., (IFNEUTRAL IS REQUIRED) AND 1#10 CU. EGC TOPANEL.

4. ELECTRIC PANEL SHOWN GRAPHICALLY,COORDINATE LOCATION WITHOWNER/ARCHITECT, OBSERVE NEC CLEARANCEAND CODE REQUIREMENTS.

5. WIRE EXHAUST FAN WITH LIGHT CIRCUIT.

6. PROVIDE WALL OCCUPANCY SENSOR/SWITCH,TYPE OCW, PER SHEET E-701.

7. PROVIDE WALL OCCUPANCY SENSOR/SWITCH,TYPE OCW2, PER SHEET E-701.

8. PROVIDE 20A, 120V-1PH DUPLEX RECEPTACLEFOR RECIRCULATION PUMP.

9. LIGHTING CONTACTOR, TIME SWITCH ANDPHOTOELECTRIC CONTROL. REFER TO"EXTERIOR LIGHTING CONTROL DIAGRAM" ONSHEET E-501.

10. PROVIDE 30A, 230V-1PH SAFETY SWITCH FORHP-1. FIELD COORDINATE EXACT LOCATION.

11. RUN 3#10 CU., (IF NEUTRAL IS REQUIRED) AND1#10 CU. EGC TO PANEL.

Scale: 1/4" = 1'-0"

1

POWER PLAN - NEW

LAUNDRY C-L

Scale: 1/4" = 1'-0"

2

LIGHTING PLAN - NEW

LAUNDRY C-L

BOLT CONNECTION WITHCOMPRESSION SPADE LUG

FITTING (TYPICAL)

COPPER BUS BAR(REFER TO DIAGRAM ANDKEYED NOTE ON SHEET E-602

STAND-OFFS

2700VINSULATORS

PAD MOUNTEDOIL-FILLEDTRANSFORMER

DANGER- HIGH VOLTAGE -

SIGN

OWNER EQUIPMENTIDENTIFIER SIGN

CONCRETE PAD

MEDIUM VOLTAGEFEEDER IN/OUT

PRIMARYCOMPARTMENT

SECONDARYCOMPARTMENT

480V SECONDARYSEE ONE-LINE FORSIZE AND QUANTITY

TIMECLOCK

4#12 IN 1/2" CONDUIT

PHOTOELECTRIC CONTROL SPEC GRADE. 1/2"CTHREADED IMC MOUNTED AT A ROOF LOCATION OUT OFPUBLIC VIEW. MANUFACTURED BY TORK #2101 OR EQUAL.

7 DAY TIME SWITCH WITH COMBINATION PHOTOELECT5RICCONTROL, MANUAL BYPASS SWITCHES, RESERVE POWER,NEMA 1 ENCLOSURE. TORK #T920L OR EQUAL.

LP-XX,XX

PROVIDE ONE (6) POLE LIGHTINGCONTACTOR ELECTRICALLYOPERATED/HELD, 120V COIL, NEMA 1ENCLOSURE, MANUFACTURED BYSQUARE D OR EQUAL. LABEL"EXTERIOR LIGHTING CONTACTOR."INCLUDE HAND/OFF/AUTO (HOA)SWITCH.

240V

240V

LP-XX

LP-XX,XX

FILE

NAM

E:

DATE

:

SHEET:

REVI

SION

:T

H O

M A

S G

I F F

O R

D A

R C

H I T

E C

TPO

BOX

319

34 S

ANTA

FE

, NEW

MEX

ICO

8759

4 P

HONE

505.6

90.58

98 F

ACSI

MILE

505.9

82.78

84 E

MAIL

THOM

ASGI

FFOR

D@CO

MCAS

T.NE

T

TGA

Cerro

Gor

do

6.17.1

3

C E

R R

O G

O R

D O

H O

U S

I N G

C E

R R

O G

O R

D O

S

A N

T A

F E

, N

E W

M E

X I C

O

E-501

DETAILSELECTRICAL

JLPD

Scale: N.T.S.

THREE-WAY SWITCHING DETAIL1

Scale: N.T.S.

PAD-MOUNT TRANSFORMER DETAIL2

Scale: N.T.S.

EXTERIOR LIGHTING CONTROL DIAGRAM3

Scale: N.T.S.

MAIN GROUNDING ELECTRODE BUS DETAIL

4

FROM UTILITYMETER

#4 CU G-N BONDING JUMPER

NG

#4 CU MAIN BONDING JUMPER

SUITABLE FOR USE AS SERVICEEQUIPMENT.

#6 CU GND

2/0 CU.

FUSED DISCONNECT SWITCH

#6 CU.

2/0 CU.

TO PANEL

MIN 20' OF #4 BARE CU OR

STEEL REINFORCING BARS INCONCRETE-ENCASED ELECTRODE PERNEC 2011 SEC 250.52 (A),(3).

#6 CU.

IBT

DCW

DWH

DC

WD

HW

5'-0"MAX

PIPEEXIT

FROMGRADE

#6 CU.

#6 CU. #6 CU.

#4 CU.

15

15

19

20

21 22

TRANSFORMERBY

PNM

M

M

M

M

M

M

GANGABLE METERPACK WITH 6- 200A

METER SPACES & MAINBREAKERS

WIRE, POLE, AND RISER BYPNM. 3" PVC UNDERGROUND

CONDUIT BY CONTRACTOR

~

3~#3/0 CU IN 2" C. 2" PVC WITH 3~3/0 CU.+1~ #6 CU GROUND

PANEL(MCB)

FILE

NAM

E:

DATE

:

SHEET:

REVI

SION

:T

H O

M A

S G

I F F

O R

D A

R C

H I T

E C

TPO

BOX

319

34 S

ANTA

FE

, NEW

MEX

ICO

8759

4 P

HONE

505.6

90.58

98 F

ACSI

MILE

505.9

82.78

84 E

MAIL

THOM

ASGI

FFOR

D@CO

MCAS

T.NE

T

TGA

Cerro

Gor

do

6.17.1

3

C E

R R

O G

O R

D O

H O

U S

I N G

C E

R R

O G

O R

D O

S

A N

T A

F E

, N

E W

M E

X I C

O

E-601

DIAGRAMSELECTRICAL

JLPD

Scale: NONE

ONE-LINE DIAGRAM RESIDENTIAL UNITS

1

Keyed Notes

1. ARRANGE FOR NEW 200A, 120/240V 3W RESIDENTIALSERVICE AND COMPLY WITH ALL PNM STANDARDS.

2. METER PER PNM STANDARDS. LOCATION PER SITE UTILITYPLAN.

3. 3~3/0 CU, 1~#6 CU EGC IN 2"C. NIPPLE.

4. 200A PANEL 20/40, MCB, RATED 10 KAIC IN NEMA 1ENCLOSURE.

5. 200A, 120/240V MAIN SERVICE (EXTERIOR)DISCONNECT/BREAKER. FOR GROUP-MOUNTED MODULARMETER/MAIN INSTALLATIONS, USE MAIN BREAKER PERUTILITY COMPANY REQUIREMENTS. FORBUILDING-MOUNTED INDIVIDUAL METER SOCKET +DISCONNECT SWITCH INSTALLATIONS, USE ENCLOSEDCIRCUIT BREAKER. ALL BREAKERS MUST BERATED/SUITABLE FOR USE AS SERVICE EQUIPMENT (SUSE)AND IN APPROPRIATE NEMA 3R ENCLOSURES.

6. 3~#3/0 CU, 1~#6 CU EGC IN 2" C. UP-SIZE CONDUCTORS PERFOOTNOTE IN "FEEDER / BRANCH CIRCUIT SCHEDULE" ASREQUIRED.

7. METER SOCKET PER UTILITY COMPANY REQUIREMENTS.(REFER TO UTILITY SITE PLANS FOR METER LOCATIONS,SOME LOCATIONS SHALL BE GROUP-MOUNTED MODULARMETER/MAIN ASSEMBLIES, SOME LOCATIONS SHALL BEINDIVIDUAL BUILDING-MOUNTED METER SOCKETS.)

8. TRANSFORMER SECONDARY CONDUCTORS. FORINDIVIDUAL BUILDING-MOUNTED METER/MAININSTALLATIONS, PROVIDE 3~#3/0 CU IN 2" C. FORGROUP-MOUNTED MODULAR METER/MAIN ASSEMBLIES,PROVIDE (2) SETS EACH OF 3~350 MCM CU IN 3" C.

9. 3~2/0 CU IN 2" C

10. ARRANGE FOR NEW 400A, 120/240V 3W RESIDENTIALSERVICE AND COMPLY WITH ALL PNM STANDARDS.

11. 3~600 CU IN 4" C

12. METER IN AN "OVER 200A" ENCLOSURE PER PNMSTANDARDS. LOCATION PER SITE UTILITY PLAN.

13. 400A, 120/240V MAIN SERVICE (EXTERIOR)DISCONNECT/BREAKER. FOR GROUP-MOUNTED MODULARMETER/MAIN INSTALLATIONS, USE MAIN BREAKER PERUTILITY COMPANY REQUIREMENTS. FORBUILDING-MOUNTED INDIVIDUAL METER SOCKET +DISCONNECT SWITCH INSTALLATIONS, USE ENCLOSEDCIRCUIT BREAKER. ALL BREAKERS MUST BERATED/SUITABLE FOR USE AS SERVICE EQUIPMENT (SUSE)AND IN APPROPRIATE NEMA 3R ENCLOSURES.

14. 400A PANEL 20/40, MCB, RATED 10 KAIC IN NEMA 1ENCLOSURE.

15. EQUIPMENT GROUNDING ELECTRODES SHALL CONSIST OFTHE COLD WATER PIPE AND TWO (2) 3/4" x 10FT GROUNDRODS. PROVIDE #4 COPPER GROUNDING ELECTRODECONDUCTOR TO THE COLD WATER PIPE ELECTRODE.PROVIDE #6 COPPER GROUNDING ELECTRODE CONDUCTORTO ALL GROUND ROD ELECTRODES. ALL CONDUCTORSEGMENTS EXPOSED TO PHYSICAL DAMAGE SHALL BEENCLOSED IN CONDUIT RACEWAY WITH APPROPRIATEBONDING FITTINGS.

16. BOND TO THE DOMESTIC COLD WATER UTILITY PIPEENTRANCE IN CRAWL SPACE WITHIN 5FT OF ENTRY USINGAPPROVED GROUNDING PIPE CLAMP.

17. BOND THE HOT AND COLD WATER PIPES AT WATER HEATERUSING A #8 BARE COPPER CONDUCTOR AND APPROVEDGROUNDING PIPE CLAMPS.

18. PROVIDE INTERSYSTEM BONDING TERMINATION (IBT)GROUNDING BRIDGE FOR CONNECTING BONDINGCONDUCTORS BETWEEN THE GROUNDING ELECTRODESYSTEM AND COMMUNICATIONS SYSTEMS (TELEPHONEAND CATV / SATELLITE TV). GROUNDING BRIDGE SHALL BEBRONZE CONSTRUCTION WITH PAINTABLE PVC COVER ANDPVC CONDUIT ADAPTER PLATE, ARLINGTON INDUSTRIES #GBB5P OR EQUAL. PROVIDE A DEDICATED #6 COPPERBONDING CONDUCTOR BETWEEN THE SERVICE PANELGROUND AND THE IBT GROUNDING BRIDGE, ENCLOSED INSUNLIGHT-RESISTANT PVC CONDUIT ON OUTSIDE OFBUILDING. INSTALL IN ACCORDANCE WITH NEC 250.94.

19. NEW POWER POLE TO BE PROVIDED BY UTILITY COMPANY.COORDINATE EXACT LOCATION WITH OWNER AND UTILITYCOMPANY. TRANSITION RISER CONDUIT TO SCH.80 PVCBURIED 4'-0" BELOW GRADE USING A RIGID SWEEP ELBOW.STUB UP PRIMARY CONDUIT IN OPENING OF TRANSFORMERPAD. PROVIDE 3/4" x 10' COPPER GROUND ROD AT BASE OFPOLE. PROVIDE GROUNDING CONDUCTOR ON POLE PERUTILITY COMPANY REQUIREMENTS.

20. PAD-MOUNTED TRANSFORMER TO BE PROVIDED BY UTILITYCOMPANY. COORDINATE EXACT LOCATION WITH OWNERAND UTILITY COMPANY. CONTRACTOR SHALL PROVIDEPRE-CAST POLYMER CONCRETE PRE-MANUFACTUREDPAD/BASE ASSEMBLY (AS MANUFACTURED BY HUBBELLQUAZITE OR EQUAL) TO BE COMPATIBLE WITHUTILITY-PROVIDED TRANSFORMER.

21. PROVIDE GANGED METERING ASSEMBLY WITH SOCKETTYPES AS SPECIFIED BY UTILITY COMPANY.

22. PANELBOARD IN UNIT. PROVIDE PERMANENTLY ATTACHEDFEEDER FROM TENANT METER. PROVIDE MAIN BONDINGJUMPER BETWEEN NEUTRAL AND GROUND BUSSES WITHINPANEL-BOARD, AND PROVIDE GROUNDING ELECTRODESYSTEM CONSISTING OF A 3/4" x 10' COPPER GROUND RODAND DOMESTIC COLD WATER (UTILITY SUPPLY) PIPEELECTRODE. COMPLY WITH PARTS I-V OF NEC ARTICLE 250.

Scale: NONE

ONE-LINE DIAGRAM LAUNDRY UNITS

2

Scale: NONE

RESIDENTIAL GROUNDING DETAIL

3

Scale: NONE

PARTIAL ONE LINE DIAGRAM (GROUPED METER/MAIN)

4

Keyed Notes Continued

FILE

NAM

E:

DATE

:

SHEET:

REVI

SION

:T

H O

M A

S G

I F F

O R

D A

R C

H I T

E C

TPO

BOX

319

34 S

ANTA

FE

, NEW

MEX

ICO

8759

4 P

HONE

505.6

90.58

98 F

ACSI

MILE

505.9

82.78

84 E

MAIL

THOM

ASGI

FFOR

D@CO

MCAS

T.NE

T

TGA

Cerro

Gor

do

6.17.1

3

C E

R R

O G

O R

D O

H O

U S

I N G

C E

R R

O G

O R

D O

S

A N

T A

F E

, N

E W

M E

X I C

O

E-701

SCHEDULESELECTRICAL

JLPD