Target Markets
General Industry Oil, Gas &
Petrochemical Water & Wastewater LPG
9010 / 9020 Control Card
9010 Single Channel Control Card Factory Configured
9020 Dual Channel Control Card Factory Configured
9010 / 9020 Controller
Control Module Features Operates with complete range of
2- or 3-wire gas sensors including: Toxic Combustible Oxygen
User-friendly configurable operation Leading edge SMD technology throughout
9010 / 9020 Controller
Control Module Features Provides real-time self-diagnostics Each module comes with an independent AC/DC
power supply transformer AC/DC automatic switching in case of
AC power failure User defined access codes prevent accidental or
undesired tampering
9010 / 9020 Controller
Control Module Features Each module has two SPDT relays with change-over
contacts for verification of Warning and Alarm conditions
Default and configuration data stored in non-volatile memory
3 Adjustable Alarm levels for Caution, Warning & Alarm (indicated by LED’s)
9010 / 9020 Display Features
4-digit back-lit LCD Choice of unit of
measure (LEL, LELm, PPM, % Vol, g/m3 or blank)
Alarm status Cal, Time-out / Off,
CWA Delay ON, Alarm inhibit
9010 / 9020 Keypad Features
Simple 3-key operation Keypad allows for:
Configuration Calibration Routine operation
▲ ▼
9010 / 9020 Output Signals
Analog (normal) - 0-20, 4-20 mA (selectable) isolated
Analog (fault) - 0,2,4,20 mA / frozen (selectable) RS 485 for connection to a printer
9010 / 9020 Controller
Configuration and Calibration No tools required for adjustment Utilizes keypad Remote non-intrusive calibrator Adjustable Calibration Timer
Reminds user of selected calibration interval User selectable 0-999 days CAL message appears on display
9020 Component Side View
9010 / 9020 Enclosures
General Purpose Plastic Protection against dust and
rain 1 – 9010 (1 point) 1 – 9020 (2 points) 4 lbs
9010 / 9020 Enclosures
Nema 4X Metal Protection against
dust and rain External Horn Acknowledge Button 5-10 – 9010
(up-to 10 points) 5-10 – 9020
(up-to 20 points) 67-100 lbs Also Available in Stainless Steel
9010 / 9020 Enclosures
Explosion Proof Metal Suitable for Class 1, Div. 1
& Div. 2 areas 1-2 – 9010
(up-to 2 points) 1-2 – 9020
(up-to 4 points) 52-86 lbs
9010 / 9020 Enclosures
Rack Mount Standard Rack Configuration Wiring in rear 10 – 9010 (up-to 10 points) 10 – 9020 (up-to 20 points) 23 lbs
9010 / 9020 Sensor Options
Passive catalytic sensor Electrochemical sensor Infrared sensor (via specific interface PCB) Ultima® X Transmitters FlameGard® 5 Flame Detectors Ultima® MOS-5 Gas Detector Ultima® OPIR-5 Open Path Gas Monitor
9010 / 9020 Controller