Page 1: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

E20/20 Step TDR

CATVOperator Training

January 24, 2012

Rev B – 11/21/12

Page 2: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Subject SlidesE20/20 Step TDR and Accessories 1-7About the E20/20 TDR 8-9Batteries & Battery Power 10How TDR’s work and Cable Construction 11-17Power On/Off, LCD Display & Example Traces 18-22Keypad & Menu Keys 23-30Function Keys 31-35Advanced Features 36-41Premise Cable Testing 42-49OSP Cable Testing 50-53ETDR PC Vision 54-61Cleaning E20/20 TDR 62Warranty, Maintenance & Contact Info 63Questions & Acknowledgements 64

Table of Contents

2

Page 3: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

E20/20 TDR with Soft Carrying Case

3

Our Soft CarryingCase is now Standard with allE20/20 TDRModels

Page 4: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

USB CableA-to-Mini B

Not Pictured:CD-ROMQuick Start GuideBasic Guide

Belt Case

E20/20 TDR & Included Accessories

E20/20F Network TDR

AC and DC PowerAdapters

4

F-to-AlligatorClips Lead

RJ-45 to TelcoClips Lead

Page 5: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

CD-ROMCD FoldersETDR PC VisionTM - - - - - - - - MS Windows XP or Win 7software TDR Application Notes - - - - - - 20+ Detailed Notes on TDR uses

Operation Manual - - - - - - - - - Electronic Copy OnlyBasic Guide - - - - - - - - - - - - - Backup to Printed CopyQuick Start Guide - - - - - - - - - Backup to Printed Copy Training PPTs - - - - - - - - - - - - General/Broadcast Training CATV Technician

Telephone TechnicianAlso available at:www.aeatechnology.com

5

Page 6: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

AC or DC Power and Recharging

12.5 VDC @ 500 mAVehicle running is preferredDC power permits operationOR recharging, but not both

100-240 VAC 50/60 HzAC power permits operation AND Recharging

6

Page 7: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Optional Accessories

Test Leads

F Test Lead4ft (1.2m) Quick Connect

DC Power Cord Ext.USB Cable Ext.

Hard Carrying Case

7

Page 8: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Connector combination for Telcomodel is F and RJ-45

E20/20 Instrument Layout

Quarter VGA backlit display

High tactile feel & weather resistantkeypad with Function Key LEDs

Rugged ABS plastic case withprop stand on the back

8

Page 9: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

E20/20F Network Top End

F Connector(field

replaceable)

USB-2 Mini Port

RJ-45 Port

DC Input power jack

ChargingIndicator LED

9

Page 10: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Battery Installation

CAUTIONNO mixing cells

Same Type & mAhr

BATTERY MENU

Select Alkaline or NiMH/NiCd andenter rated mAhrs

10

Meter

Page 11: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

How Does a TDR Work?The same as RADAR

Time

11

Page 12: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Cable Velocity and DistanceVelocity is designed in a cable at the time of its manufacture

Velocity is expressed as a fraction of the speed of light

Examples: .66c or 66.7c

Time 2

X Velocity = Distance

20 n Sec 2

X .66c (648,172,800ft/sec) = 6.48 feet

VF or

VPBeware of VF Uncertainty

VoP or

NVP

12

Page 13: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Impedance “Z”

Z = 75 OhmsZ = 100 Ohms

13

Page 14: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Cable Impedance (Z) and ReflectionsImpedance is a factor of both the conductor and the dielectric of the insulation between the conductor & shield or twisted pairs

Any deviation from the manufactured Z will cause reflections

OpenZo=75 or 100

Z = ∞Ω Open

Z = 0

Zo=75 or 100Short

Short

14

Page 15: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Pulse TDR

Pulse TDR

Longer and Longer Dead Zones

15

Page 16: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Step TDR = No Dead Zones – Any Range Fault readings in Ohms

Step TDR

16

Page 17: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Example Step TDR Reflections

Good Splice

Poor Splice

Mixed Impedances Bridged Tap

Water Split Pair ThatResplits

Pinched Coax

Poor QualityCoax

12

910

13

What a “Pulse TDR” Cannot See

17

Page 18: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

ON cycle runs Self Test, Calibration, and Restores last use settings

Input Voltage Detect Warning (>1VAC pk-to-pk or 50VDC)OFF cycle saves all settings

Battery Saver shuts down saves all settings

Powering Up/Down

Input over-voltage protection up to 250 VAC or DC

18

Page 19: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Soft Reset & Hard Power Down Perform Soft Reset if: 1. TDR menu cursors are unresponsive

2. Measurement Screen disorganized 3. Other performance issues

Perform a Hard Power Down if TDR will not turn off normally

Press and hold for 10 secondsThen power on with a Soft Reset

19

ENTER Then

“Default Settings” will flashin the splash screen andMeasurement Screen willopen to 0-1KΩ Z Scale

ENTERThen

1 SecPress & Hold 2 Sec Release

Page 20: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Measurement ScreenCable Type,Impedance, &Velocity

ImpedanceScale

Plot Range

Cursor Data – Feet, Inches or meters and Impedance

1 of 2 Cursors

Blinking LowBattery indicator(~20 minutes power remaining)

20

Page 21: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Example E20/20 TDR TracesSeries Resistive Fault Cable Short

Pinched Coax Wet Cable

21

Page 22: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Coax Shield Fault

Good Splice Bad Splice

Bridged Tap

Example E20/20 TDR Traces

22

Page 23: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Menu keysBy name

LED’s indicateactive Function keys Cable ID tones

for coax &twisted pair

Cell style alpha-numeric entrypad

Keypad

Exits menu andsaves changes

Enters A/N changes,distance marks, &Soft Reset

ON/OFF

Cursors, & dataselectioncontrol

23

Page 24: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

ENTER

Used to confirm or accept alpha-numeric entries, highlightedlist selections and cursor marked entries for certain features

Soft Reset - Press 4-5 times fast after pressing ON key to activate.

EscReturn to Measurement Screen from menu or back up one menu level. Saves all menu changes

Keypad Controls

24

Page 25: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

HELP OVERVIEW

SETUP WIZARDMENU OPERATIONTHE CABLETHE TEST LEADSKEY FUNCTIONS

‘ ‘,’ ‘: SELECT A TOPIC ‘ENTER’:VIEW TOPIC HELP

Help

Step-by-step set up guidance

How the menus work

Cable menu options guide

Test Lead Null guide

Action keys’ LEDs guide

With NO action keys or other menu key selected

Help Key

25

Page 26: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Context sensitive help workswith active Function keysor menu keys and cursor selected features and functions

Help

Context Sensitive Help Example

26

RANGE CONTROL : INCREASE RANGE : DECREASE RANGE

ADJUSTS THE TOTAL DISTANCEDISPLAYED ON THE TRACE

Range

Page 27: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

METER SETTINGS

BACKLIGHT : HIGHCONTRAST : 9INPUT CHANNEL : COAX INPUTKEYPAD BEEP : ONBATTERY MENU : ABOUT 5.5HRSDATE/TIME :

22 DEC 2011 12:10PM

Meter

Off, Low, Med, & High

Raise for cold, lower for hot

Coax or RJ45 CH A thru D

Sub menu to change

ON or OFF

Meter Menu

27

to open full menu

Page 28: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

TRACE OPTIONS

Z SCALE (OHMS) : 200TRACE RANGE : 50START DISTANCE : 0MICRO FAULT : OFFTEST LEAD NULL : OFFNOISE FILTER : OFF

Trace

20, 50, 100, 200, 500, & 1K

10ft – 20Kft (2m – 5Km)

Shifts display range by entry. 0 = TDR connector or Test Leadend if Test Lead Null ON

ON or OFF (slide 39 for details)ON or OFF

OFF, KINKS ONLY or ALL FAULTS (slides 37 & 38 for details)

Trace Menu

28

Page 29: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Memory MenuMemory

MEMORY OPERATIONS

SAVERECALLPRIOR SETTINGS

ENTER MEMORY NAME‘0’ TO ‘9’: DIGIT OR CHARACTER : MOVE EDIT CURSOR : ERASE/START OVER‘ENTER’ : ACCEPT AND CONTINUE

**ENTER NAME* *

1 2 3

4 5 6

7 8 9

Bcksp 0

. , A B C D E F

G H I J K L M N O

PQRS T U V WXYZ

% & =

MEMORY RECALL OPERATION

* * * START OF LIST* * *LMR-400 ANT-2 Z50 VF 85.0RG-58 XMIT-6 Z50 VF 83.5RG-58 XMIT-8 Z50 VF 83.5CAT5 CONTL LINE Z100 VF 72.3LMR-400 ANT-1 Z50 VF 85.0* EMPTY SLOT*SAVED 30 AUG 2011 10:31AMENTER:SELECT SLOT, ESC:QUIT

29

Delete Trace – Highlight –CAUTION: NO UNDELETE

Bcksp

Page 30: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Cables Menu

CABLE SELECTION

PICK/EDIT LISTMANUAL ENTRYVELOCITY SRCH.SAMPLE A CABLEDISTANCE UNITS: FEET

SELECTED CABLE:COMSCOPE .625 ZO 75 VF 87.0

Cables

Compute a cable’s VFby testing a sample ofknown length – guidedprocess

ENTER THE CABLE MANUALLY

DESCRIPTION : SAMPLEDCABLE Z0 : 50VELOCITY FACT. : 67.6

Find a cable’s VF from knownpoints – guided process

30

CABLES LIST***START OF LIST***GENERIC RG8/U Z0 52 VF 66.0TIMES RG6/U Z0 75 VF 66.0IW-CAT 3 24AWG Z0 100 VF 67.0IW-CAT 5 24AWG Z0 100 VF 70.0IW-CAT 5E 24AWG Z0 100 VF 72.0

‘ENTER’:SELECT THIS CABLE‘BCKSP’: EDIT CABLE ‘ESC’: QUIT

Page 31: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Range

Minimum 10 ft or 2m

Maximum 20Kft or 5Km

Increase/decrease display range

31

Page 32: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Zoom

Zoom Limits: Minimum 10ft (2m) to Maximum Set Range

Zooms on active cursor

32

Page 33: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Z Scale

Scales: 20, 50, 100, 200, 500, & 1KΩ

On lower Scale settings cable Z0 will stay centered

33

Page 34: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Single active cursor has LED litRules when both cursors are on screen:1. Both LEDs are lit2. Last cursor key touched is active3. Last cursor key touched appears on

LCD with differential readings to othercursor’s – distance and Ohms

Crsr 1 Crsr 2Crsr 2

34

Page 35: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Tone

Tones generated on coax orselected twisted pair

Most standard inductiveamplifiers (probes) will pickup the tones

TDR trace is not availablewhile toning the cable.Battery Saver is suspended

Meter INPUT CHANNEL:

TONE GENERATOR‘ ‘,’ ‘: SELECT A DIFFERENT TONE‘BCKSP’: VIEW THE LIST OF TONES‘TONE’: EXIT TO TDR MODE

INJECTING A WARBLE TONE ONTO:RJ45 CH A

WARBLEPRESENT VALUE: 900/1100HZ Press for a menu of

Tones

Bcksp

35

TONE GENERATOR LIST900/1100 HZ WARBLE977.5 HZ STEADY977.5 HZ PULSED850 HZ STEADY850 HZ PULSED577 HZ STEADY577 HZ PULSED

Use onBattery poweronly

Page 36: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

E20/20 TDR Advanced Features

TraceMICRO FAULT – Locate minute defects in coaxTEST LEAD NULL – Remove unknown test lead length from measurement

CablesVELOCITY SEARCH – Pin-Point an installed cable’s

true VF based on cable’s known length or known distance to an event.

SAMPLE A CABLE – Find the VF for a cable sample to apply to all the cable in that box, reel or lot number.

36

Page 37: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Micro Fault

Trace MICRO FAULT – KINKS ONLY

37

For small kinks and crushesin coax cablesTDR’s normal display will

shift to an amplified reflectiondisplay with Z0 as base line . In this example a fault barelyseen in the normal impedance display shows up clearly.

Page 38: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Micro FaultTrace MICRO FAULT – ALL FAULTS

38

Mainly for coax or highquality twisted pairsTDR’s normal display will

shift to an amplified reflectionDisplay Z0 centered, no dribble-up & reduced Z Scale. In this example a fault barelySeen in the normal impedance display shows up clearly.

Page 39: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Test Lead Null

Trace

TRACE OPTIONS

Z SCALE (OHMS) : 200TRACE RANGE : 50START DISTANCE : 0MICRO FAULT : OFFTEST LEAD NULL : OFFNOISE FILTER : OFF‘ ‘=OFF, ‘ ‘=ON,”ENTER”=SET NULL

Use a cursor to mark theEnd of the test lead and Press to set the length

ENTER

39

Page 40: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Velocity SearchWhen to use – If you have an installed cable with known lengths either to the end or an event on the cable. E20/20 willcompute the cable’s VF based on marking the distance with acursor, then use the to adjust the cable end or event tothat distance.

Press when end ofcable and cursor are alignedto use the modified VF andreturn to Measurement Screen

ENTER

40

Page 41: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Sample a CableWhen to use – If you have a cable sample 10-50ft (3-15m)with an accurately measured length, and plan to install or test cable’s from it’s same reel or box.

41

Mark the end of the sample.Press and enter ft then in.Press TDR computes VFENTER

Page 42: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Transition from the Theoretical to the Practical

How can a TDR help you get a clear TV picture,a quality phone call or a fast internet connection

42

Page 43: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Kitchen

Living RoomBedroom 1

Bedroom 2

Bedroom 3Kitchen

Living RoomBedroom 1

Bedroom 2

Bedroom 3

Typical Telco Loop Wiring NID

Telco USOC Wiring Scheme for Homesand Small Businesses

1 – T3 not connected2 – T2 Black3 – R1 Red4 – T1 Green5 – R2 YellowYellow6 – R3 not connected

RJ12 WiredUSOC

1 – T2 Black2 – R1 Red3 – T1 Green4 – R2 YellowYellow

RJ11 WiredUSOC

43

Page 44: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

NID

Kitchen

Living Room

Bedroom 1

Bedroom 2

Bedroom 3

Typical Star or Home Run Wiring

TIA 568C for Business Wiring or TIA 570B for Residential Wiring

66 Block or110 Block orConnectionBox

1 – T3 White/Green2 – T3 Green3 – T2 White/Orange4 – R1 Blue5 – T1 White/Blue6 – R2 Orange7 – R4 White/Brown8 – R4 Brown

RJ45 WiredT-568A

1 – T3 White/Orange2 – T3 Orange3 – T2 White/Green4 – R1 Blue5 – T1 White/Blue6 – R2 Green7 – R4 White/Brown8 – R4 Brown

RJ45 WiredT-568B

44

Page 45: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

AEA Technology Reduced All Wiring Schemes to Coax & 4 RJ45 Channels

99.9% of all phone lines will be on TDR’s Channel A or look at any other single pair

ETDR PC Vision can upload, modify, store & download cable lists to the E20/20 TDR

The E20/20 TDR in impedance independent and can test both coax and twisted pair cables with the same TDR The E20/20 TDR has a customized cable list for Telco techs that covers OSP cable, air or gel filled, drops and premises twisted pairs (IW) for Cat 2 through

Cat 6, and coax.

45

Page 46: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

0 160 320

200

150

100

50

0

CRSR1 291ft 10in 101.4 to 101.6

GENERIC 24AWG VF 66.7

0 160 320

200

150

100

50

0

CRSR1 291ft 10in 101.4 to 101.6

GENERIC 24AWG VF 66.7

Kitchen

Living RoomBedroom 1

Bedroom 2

Bedroom 3

Shorting Plug

Three Step Check1. Unplug all

phones2. Connect the

TDR at NID3. Locate end

jack using ashorting plug

Open and shortat end jack indicates a good pair run. Test canbe repeated for all pairs.

Results NID

46

Page 47: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

0 160 320

200

150

100

50

0

CRSR1 155ft 3in 101.4 to 101.6

GENERIC 24AWG VF 66.7

0 160 320

200

150

100

50

0

CRSR1 155ft 3in 101.4 to 101.6

GENERIC 24AWG VF 66.7

Three Step Check1. Unplug all

phones2. Connect the

TDR at NID3. Locate last

visible jack using a shorting

plugFault is a brokenwire after the jackconnection inBedroom 1’s jack

Results

Kitchen

Living RoomBedroom 1

Bedroom 2

Bedroom 3

NID

Shorting Plug

Shorting Plug

Shorting Plug

47

Page 48: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Kitchen

Living RoomBedroom 1

Bedroom 2

Bedroom 3

NID

0 160 320

200

150

100

50

0

CRSR1 174ft 7in 101.5 to 101.8

GENERIC 24AWG VF 66.7

Three Step Check1. Unplug all

phones2. Connect the

TDR at NID3. Note short at

Bedroom 2with no shortingplug.

Look for bent pinsor shorted wiresinside the jack

Results

48

Page 49: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Premises Advantage of a TDR? Quickly locate the distance to a fault and see type of fault

Stop rewiring premise twisted pairs when a simple 5 minutefix will clear the trouble

95% of all premise telco wiring problems are in the jacks

1. Customer pulled out jack and broke a wire

2. Customer rewired jack and disrupted service

3. Bent or broken pins

4. Cat marked territory and corroded jack pins

49

Page 50: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

OSP Testing and Fault Locating

Example Range Resolutions: 10ft=0.5inch, 500ft=2ft, 2000ft=8ftUse “Zoom” to improve horizontal resolution at cursorUse “Z Scale” to increase vertical resolution – Minimum +10 Ohms

Measure Cable’s Impedance (Z) & Resistance (Ω) “Dribble Up”

Use Noise Filter to clear the trace from noise. Yes! Detects Noise

Locates Distance and Impedance effects for:Poor Splices Bad ConnectionsSeries Resistance Cable DamageWet Cable Load CoilsImpedance Mismatches Lossy Cable

Ranges: 0-10ft to 0-20Kft

50

Page 51: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Water in OSP CablingWater Rules1. Reduces the resistance ofthe wire’s insulation -Hence reduces cable’s Z.2. Reduces velocity to anunknown – Distances in awater slug or after the slug areNOT valid.

1374 ft

464 ft water599 ft 311 ft

51

Wet Cable

Only trusted distanceis TDR to start of water

Page 52: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Cross Connects, Pedestals,And Splices

52

Add screen shots

Page 53: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Questions on E20/20 TDR?

53

Next subject – ETDR PC Vision

Page 54: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

ETDR PC VisionTM SoftwareOperates on: Windows XP®, Windows 7® or Vista® Platforms

Upload TDR’s saved or current traces to the PC

Archive the traces on the PC or other memory media

No platform license – Load on any number of PC’s

Upload and Download Cable Lists to the E20/20 TDR

Upload and Download instrument setups to the E20/20 TDR

54

Page 55: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Getting Started with ETDR PC Vision1. Locate ETDR PC Vision folder on the enclosed CD-ROM

or download it from www.aeatechnology.com

2. Turn on the E20/20 TDR and wait for the MeasurementScreen (will not communicate if off or in menus).

4. Double-click the icon on the desktop to open application

3. Connect the TDR and PC using the supplied USB Cable

55

Page 56: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

User Friendly Communications SetupETDR PC Vision automatically scans for the E20/20 TDR when it opens

56

FTDI DriversMay need to beinstalled. Driversare located on enclosed CDand instructionsare in the Operator Manual.

Page 57: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Get Trace Tab

57

TDR’s currentLCD trace

Open a previouslysaved trace onthe PC or otherstorage media.Usable withoutTDR connected

Page 58: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Stored Traces Tab

ANTENNA 2 50 78.6 12/30/11 11:58ANTENNA 5 50 78.6 12/30/11 12:26CON. 401 100 67.7 1/3/12 07:39CON. 331 100 67.7 1/3/12 08:38SENSOR 6-1 100 72.3 1/5/12 09:11SENSOR 6-2 100 72.3 1/5/12 09:15FLIR 1 75 74.8 1/10/12 10:27

58

Press first toupload a listof stored traces

Direct save TDRmemory to PCfolderCaution – There is NO UNDELETE

Page 59: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Graphic Plot Screen

59

Page 60: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Setup Tab

60

Press eitherto obtainvalid data(gray text is not valid)

Page 61: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Cables TabRead the CableList from TDRor from a stored list on thePC

Use these keys and “Select Cable Values” to edit the list

Write the CableList to the TDRor to a stored liston the PC

61

Page 62: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Cleaning Your 20/20 TDR1. Always spray cleaners and rinse water on a soft cloth, do NOT

spray directly on the TDR

Soft CasesThe soft case should be cleaned the same as the instrument. Usea soft bush to remove tough dirt. Do NOT immerse in water or dryin a dryer. Wash and Dry separately, both instrument and case should be dry before enclosing the instrument in the case.

2. Typical Grime – Use a mild non-abrasive detergent like 409® in water or glass cleaner (non-ammonia) and rinse water to clean

3. Cable Gel – User liquid “citrus” cleaner to remove

4. Tar, creosote or adhesives – Use WD40® followed with milddetergent and water

62

Page 63: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Maintenance, Service and WarrantyBasic Guide or Operator Manual, Maintenance, Service & Warranty.

Warranty – One year against material & workmanship defects

Questions, By all means – Contact us:

AEA Technology, Inc.5933 Sea Lion Place, Ste 112Carlsbad, CA 92010Tel: 800-258-7805 or +1-760-931-8979Fax: +1-760-931-8969

www.aeatechnology.comEmail

Application Notes

Operating Manuals

TDR PC VisionData Sheets

See “User Troubleshooting Guide”

63

Quick Start Guide

Page 64: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12

Questionson

E20/20 Step TDR ETDR PC Vision software?

Windows 7, Vista, and Windows XP are registered trademarks of Microsoft® Corp.409 is a registered trademark of Clorox® Corp.WD-40 is a registered trademark of WD-40® company

64