eagle lake drww.charmeck.org/planning/rezoning/2017/095-110/2017-097... · 2018-02-16 · sheet...

3
P:\2017 Jobs\17026 - CLT Shopton Road Site\CAD\Sketch Planning\17026 BASE.dwg N 0' 200' 400' SCALE: 1"=200' 800' Landworks Design Group, P.A. 7621 Little Avenue, Suite 111 Charlotte, NC 28226 704-841-1604 fax: 704-841-1604 Date By Description REVISIONS: No. Sheet Number: SHEET # 1 OF 3 Project Manager: Drawn By: Checked By: Date: Project Number: MDL MDL SHOPTON ROAD SITE CHARLOTTE DOUGLAS INTERNATIONAL AIRPORT CHARLOTTE, NC 05/22/17 17026 MDH RZ-1 CORPORATE CERTIFICATIONS NC PE : C–2930 NC LA : C–253 SC ENG : NO. 3599 SC LA : NO. 211 SHOPTON RD (SR 1155) SHOPTON RD STEELE CREEK RD INTERSTATE - 485 INTERSTATE- 77 S TRYON ST BILLY GRAHAM PKWY W TYVOLA RD WEST BLVD SCALE: NTS BEAM RD SITE PINECREST DR FEMA FLOODPLAIN EXISTING POWER LINE R/W 100' BUFFER CLASS A UNDISTURBED BUFFER 50' BUFFER TECHNICAL DATA SHEET SITE DATA: TAX PARCEL ID: 14108302, 14107125, 14107126, 14107121, 14107104, 14124107, 14107106, 14107122, 14107123, 14107109 ACREAGE: ± 168.2 EXISTING ZONING: R-3 PROPOSED ZONING: I-1 (CD) (INDUSTRIAL) 5 YRS VESTED EXISTING USE: VACANT PROPOSED USE: COMMERCIAL/INDUSTRIAL/WAREHOUSE PARK PROPOSED MAXIMUM SF: 2,000,000SF FLOOR AREA RATIO: .8 MAX MAX BUILDING HEIGHT: 40' MAX NUMBER OF BUILDINGS: 20 REQUIRED PARKING: PER ORDINANCE REQUIREMENTS MIN. SETBACK: PER ORDINANCE REQUIREMENTS MIN. SIDE YARD: PER ORDINANCE REQUIREMENTS MIN. REAR YARD: PER ORDINANCE REQUIREMENTS REQUIRED TREE SAVE: PER ORDINANCE REQUIREMENTS REZONING PETITION: 2017- 97 SITE ACCESS (TYP.) PCO BUFFER PER GIS (TYP.) 100' BUFFER 57' BUFFER W/ FENCE DEVELOPMENT AREA (TYP.) DEVELOPMENT AREA (TYP.) 100 YR FLOODPLAIN SHOPTON RD SIRONA DR PLEASANT WAY LN LEBANON DR AYRSHIRE GLEN PL 1 1 1/12/18 MDH REVISIONS PER STAFF, COMMUNITY & PETITIONER COMMENTS R12-MF R12-MF R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 I-2 (CD) R-3 R-3 R-3 O-1 (CD) I-2 (CD) R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 R-3 MECKLENBURG COUNTY DEED BOOK 29017 PAGE 59 PARCEL ID: 20101169 C/O REAL ESTATE /FINANCE DEPT, |MECKLENBURG COUNTY, DEED BOOK 4658 PAGE 478 PARCEL ID: 14106103 ZONING: N/A USE: RECREATION 100' SWIM BUFFER GIS (TYP.) LEGEND EXISTING CONTOUR SWIM BUFFER POSSIBLE GREENWAY EASEMENT PROPERTY LINE DEVELOPMENT AREA OVERHEAD POWER VOLUNTARY TREE SAVE EAGLE LAKE DR Development Standards DEVELOPMENT AREA (TYP.) 1 VOLUNTARY NO BUILD ZONE/TREE SAVE EASEMENT FOR COFFEY CREEK GREENWAY EXENSION(100' FROM TOP OF BANK) 1 1 100' BUFFER R200' VICINITY MAP 1. General Provisions a. Development of the site will be controlled by the standards depicted on this site plan and by the standards of the Charlotte Zoning Ordinance. The development depicted on this plan is intended to reflect the arrangement of proposed uses on the site, but the exact configuration, placement, and size of individual site elements may be altered or modified within the limits prescribed by the ordinance during the design development and construction phases as allowed under the provisions of Section 6.2 of the Zoning Ordinance. b. The Petitioner acknowledges that other standard development requirements imposed by other city ordinances, such as those that regulate streets, sidewalks, trees, bicycle parking, and site development, may apply to the development of this site. Unless specifically noted in the conditions for this site plan, these other standard development requirements will be applied to the development of this site as defined by those other city ordinances. c. Throughout this Rezoning Petition, the terms "Owner", "Owners", "Petitioner" or "Petitioners," shall, with respect to the Site, be deemed to include the heirs, devisees, personal representatives, successors in interest and assignees of the owner or owners of the Site who may be involved in its development from time to time. d. The total number of principal buildings to be developed on the Site shall not exceed 20. Accessory buildings and structures (as defined by the Zoning Ordinance) located on the Site shall not be considered in any limitation on the number of buildings on the Site. 2. Purpose a. The purpose of this Rezoning application is to provide for the development of a commercial/industrial/warehouse park. To achieve this purpose, the application seeks the rezoning of the site to the Industrial 1 (I-1(CD)) district. 3. Uses a. Permitted Uses. Uses allowed on the property included in this Petition will be primary and related accessory uses as are permitted in the I-1 district with the exception of those listed in b. Prohibited uses. b. Prohibited uses. i. Jails and prisons; Religious institutions; Adult establishment; Auction sales; Automobile service stations; Automobiles, truck and utility trailer rental; Billboards ; Commercial rooming houses; Flea market establishment; Hotels and motels; Homeless shelter; Overnight camping area; Beneficial fill site; Land clearing and inert debris landfill (LCID): off-site, mobile food vending services; Raceways and dragstrips; Crematory, within a cemetery; Barber and beauty Shops; Financial institutions; Retail establishments; Shopping centers and business and recreation uses; Edee (Type I and II); Gas stations, with or without a convenience store; Personal services uses, and uses with an accessory drive-through window; Amusement, commercial outdoors; Animal crematoriums; Armories for meeting and training of military organizations; Automotive repair garages; Automotive sales and repair; Bakeries, retail; Boat and ship sales and repair; Bus and train terminals; Car washes; Civic, social and fraternal facilities; Clinics, medical, dental,and optical; Clinics, veterinary; Dry cleaning and laundry establishments; Farms, including sales of products grown on premises; Heliports and helistops; Locksmiths and gunsmiths; Manufactured housing repair or sales; Orthotics - prosthetics facilities; Outdoors seasonal sales; Pest control and disinfecting services; Post offices; Recycling centers, including drop-off centers; Tattoo establishment; Theaters, motion picture. 4. Transportation a. The site will have access via drive connections to Shopton Road at the locations prescribed by NCDOT & CDOT as generally identified on the concept plan for the site. b. Petitioner will coordinate with NCDOT, CDOT, and Planning to improve the project's Shopton Road frontage, and to provide a road widening conforming to detail 3 on page RZ-3 of this document. c. Petitioner agrees to convey fee simple all the rights of way to the City of Charlotte prior to the issuance of the first building certificate of occupancy. d. All transportation improvements will be approved and constructed prior to the issuance of the first building certificate of occupancy. e. Petitioner agrees to dedicate an 85' right of way to allow for the future extension of Shopton Road by others. The exact configuration of the 85' right of way may be subject to adjustment in coordination with CDOT and the Petitioner during the site design and permitting phase. Prior to the extension of Shopton Rd, the Petitioner may develop the right of way to Local Industrial Street standards, centered within the 85' right of way. See detail 5/RZ-3. 5. Architectural Standards a. Building Placement and Site Design shall focus on and enhance the pedestrian environment on public or private network required streets, through the following: i. Buildings shall present a front or side façade to all streets. ii. Facades fronting streets shall include a combination of windows and operable doors for a minimum of 30% of each frontage elevation transparent glass between 2' and 10' on the first floor. Up to 20% of this requirement may be comprised of display windows. For industrial and warehousing buildings, these standards shall apply only at the main entry and exterior office facades. iii. Direct pedestrian connection should be provided between street facing doors fronting public access and corner entrance features to sidewalks on adjacent streets. iv. Building elevations shall not have expanses of blank walls greater than 20 feet in all directions. Architectural features such as but not limited to banding, medallions or design features or materials will be provided to avoid a sterile, unarticulated blank treatment of such walls. v. Building elevations shall be designed with vertical bays or articulated architectural features which shall include a combination of at least three of the following: a combination of exterior wall offsets (projections and recesses), columns, pilasters, change in materials or colors, awnings, arcades, or other architectural elements. vi. Buildings should be a minimum height of 22' and maximum of 40. 6. Streetscape, Buffers, and Landscaping a. Petitioner will coordinate with NCDOT, CDOT, and Planning to improve the project's Shopton Road frontage, and to provide a road widening conforming to detail 3 on page RZ-3 of this document. b. The Petitioner will provide a 100' undisturbed buffer along the site frontage with Pinecrest Drive, planted as required to meet Class A buffer standards. The Petitioner will provide a 50' Class A buffer along the Shopton Road frontage. Other buffers will be provided as required by the Zoning Ordinance. The buffer may be reduced or eliminated if abutting property is rezoned to a district or use that does not require a buffer. Petitioner will provide an additional no build zone at the north end of this site as dimensioned on RZ-2. c. Development within the site will comply with City of Charlotte Tree Ordinance Requirements. d. A six (6) foot security fence will be installed on the eastern side of the buffer along Pinecrest Rd/Eagle Lake Dr as generally depicted on the rezoning plan. 7. Environmental Features a. The Petitioner shall comply with the Charlotte City Council approved and adopted Post Construction Stormwater Ordinance. The location, size, and type stormwater management systems depicted on the rezoning plan are subject to review and approval as part of the full development plan submittal and are not implicitly approved with this rezoning. Adjustments may be necessary in order to accommodate the actual stormwater treatment requirements and natural site discharge points b. Prior to construction permitting, the Petitioner will have a Preliminary Wetlands Assessment conducted on the property to identify possible locations of jurisdictional wetlands and streams within the development area. Any proposed impacts will be permitted as required through the appropriate agencies having jurisdiction. c. All utilities within the Site will be placed underground. d. The site shall be served by the Charlotte Water department for potable water and sanitary sewer utilities. No irrigation wells shall be permitted or constructed on the site without permission of Mecklenburg County Land Use and Environmental Services Agency in order to avoid conflicts with possible nearby groundwater contamination sites. 8. Parks, Greenways, and Open Space a. The Petitioner agrees to grant an easement within the site to Mecklenburg County Parks and Recreation, measured 100' from the top of bank along Coffey Creek, for the purpose of future extension of the Coffey Creek Greenway from Douglas Drive to Shopton Road. b. The Petitioner agrees to provide up to two pedestrian connection easements (30' width) to the proposed Coffey Creek Greenway in locations generally depicted on RZ-2. 9. Fire Protection a. All public streets within the proposed development will provide an 20' wide clear travel path for the fire truck access. Any streets less than 26' pavement width will be prohibited from on street parking. 10. Signage a. Reserved 11. Lighting a. Reserved 12. Phasing a. Reserved 13. Binding Effect of the Rezoning Application a. If this Rezoning Petition is approved, all conditions applicable to development of the Site imposed under the Rezoning Plan will, unless amended in the manner provided under the Ordinance, be binding upon and insure to the benefit of the Petitioner, current, and subsequent owners of the Site and their respective successors in interest and assigns. b. Throughout these Development Standards, the term “Petitioner” shall be deemed to include the heirs, devisees, personal representatives, successors in interest and assigns of Petitioner or the owner or owners of the Site from time to time be involved in any future development thereof. c. Any reference to the Ordinance herein shall be deemed to refer to the requirements of the Ordinance in effect as of the date this Rezoning Petition is approved. 1 1 1 1 APPROXIMATE LOCATION EAGLE LAKE GATE BEGIN 6' SECURITY FENCE AT GATE 2 02/15/18 MDH REVISIONS PER STAFF COMMENTS 2 NO DEVELOPMENT PERMITTED IN THIS STRIP 2 2 30' SETBACK ALONG SHOPTON RD 2 2 100' BUFFER CLASS A UNDISTURBED BUFFER 2 2 1 1 1 1 1 2 2 2 2 2 150' BLDG SETBACK ALONG EAGLE LAKE DR/PINECREST DR 2

Upload: others

Post on 14-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EAGLE LAKE DRww.charmeck.org/Planning/Rezoning/2017/095-110/2017-097... · 2018-02-16 · sheet number: sheet # 1 of 3 project manager: drawn by: checked by: date: project number:

P:\2

01

7 Jo

bs\1

70

26

- C

LT

S

ho

pto

n R

oa

d S

ite

\C

AD

\S

ke

tch

P

la

nn

in

g\1

70

26

B

AS

E.d

wg

N

0' 200' 400'

SCALE: 1"=200'

800'

Land

work

sDe

sign

Grou

p, P

.A.

7621

Littl

e Ave

nue,

Suit

e 111

Char

lotte

, NC

282

2670

4-84

1-160

4 f

ax: 7

04-8

41-16

04

Date By Description

REVISIONS:

No.

Sheet Number:

SHEET # 1 OF 3

Project Manager:

Drawn By:

Checked By:

Date:

Project Number:

MDL

MDL

SH

OP

TO

N R

OA

D S

IT

E

CH

AR

LO

TT

E D

OU

GLA

S

IN

TE

RN

AT

IO

NA

L A

IR

PO

RT

CH

AR

LO

TT

E, N

C

05/22/17

17026

MDH

RZ-1

CORPORATE CERTIFICATIONS

NC PE : C–2930 NC LA : C–253

SC ENG : NO. 3599 SC LA : NO. 211

SHOPTON RD

(SR 1155)

SHOPTON RD

S

T

E

E

L

E

C

R

E

E

K

R

D

IN

TE

RS

TA

TE

- 485

I

N

T

E

R

S

T

A

T

E

-

7

7

S

T

R

Y

O

N

S

T

B

I

L

L

Y

G

R

A

H

A

M

P

K

W

Y

W

T

Y

V

O

L

A

R

D

W

E

S

T

B

L

V

D

SCALE: NTS

B

E

A

M

R

D

SITE

P

IN

E

C

R

E

S

T

D

R

FEMA FLOODPLAIN

E

X

I

S

T

I

N

G

P

O

W

E

R

L

I

N

E

R

/

W

100' BUFFER CLASS

A UNDISTURBED

BUFFER

50' B

U

FF

ER

TECHNICAL

DATA SHEET

SITE DATA:

TAX PARCEL ID: 14108302, 14107125, 14107126, 14107121,

14107104, 14124107, 14107106, 14107122,

14107123, 14107109

ACREAGE: ± 168.2

EXISTING ZONING: R-3

PROPOSED ZONING: I-1 (CD) (INDUSTRIAL) 5 YRS VESTED

EXISTING USE: VACANT

PROPOSED USE: COMMERCIAL/INDUSTRIAL/WAREHOUSE

PARK

PROPOSED MAXIMUM SF: 2,000,000SF

FLOOR AREA RATIO: .8 MAX

MAX BUILDING HEIGHT: 40'

MAX NUMBER OF BUILDINGS: 20

REQUIRED PARKING: PER ORDINANCE REQUIREMENTS

MIN. SETBACK: PER ORDINANCE REQUIREMENTS

MIN. SIDE YARD: PER ORDINANCE REQUIREMENTS

MIN. REAR YARD: PER ORDINANCE REQUIREMENTS

REQUIRED TREE SAVE: PER ORDINANCE REQUIREMENTS

REZONING PETITION:

2017-97

SITE ACCESS (TYP.)

P

C

O

B

U

F

F

E

R

P

E

R

G

IS

(

T

Y

P

.)

100' BUFFER

57' BUFFER

W/ FENCE

DEVELOPMENT AREA (TYP.)

DEVELOPMENT AREA (TYP.)

1

0

0

Y

R

F

L

O

O

D

P

L

A

I

N

S

H

O

P

TO

N

R

D

S

IR

O

N

A

D

R

P

LE

A

S

A

N

T

W

A

Y

LN

LE

BA

NO

N D

R

A

Y

R

S

H

I

R

E

G

L

E

N

P

L

1

1 1/12/18 MDH REVISIONS PER STAFF, COMMUNITY & PETITIONER

COMMENTS

R12-MF

R12-MF

R-3

R-3R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

I-2 (CD)

R-3

R-3

R-3

O-1 (CD)

I-2 (CD)

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

R-3

MECKLENBURG COUNTY

DEED BOOK 29017 PAGE 59

PARCEL ID: 20101169

C/O REAL ESTATE /FINANCE

DEPT, |MECKLENBURG COUNTY,

DEED BOOK 4658 PAGE 478

PARCEL ID: 14106103

ZONING: N/A

USE: RECREATION

1

0

0

' S

W

IM

B

U

F

F

E

R

G

IS

(T

Y

P

.)

LEGEND

EXISTING CONTOUR

SWIM BUFFER

POSSIBLE GREENWAY EASEMENT

PROPERTY LINE

DEVELOPMENT AREA

OVERHEAD POWER

VOLUNTARY TREE SAVE

E

A

G

LE

LA

K

E

D

R

Development Standards

DEVELOPMENT AREA (TYP.)

1

VOLUNTARY

NO BUILD

ZONE/TREE

SAVE

EASEMENT FOR COFFEY CREEK

GREENWAY EXENSION(100' FROM

TOP OF BANK)

1

1

100' BUFFER

R

2

0

0

'

VICINITY MAP

1. General Provisions

a. Development of the site will be controlled by the standards depicted on this site planand by the standards of the Charlotte Zoning Ordinance. The development depicted onthis plan is intended to reflect the arrangement of proposed uses on the site, but theexact configuration, placement, and size of individual site elements may be altered ormodified within the limits prescribed by the ordinance during the design developmentand construction phases as allowed under the provisions of Section 6.2 of the ZoningOrdinance.

b. The Petitioner acknowledges that other standard development requirements imposedby other city ordinances, such as those that regulate streets, sidewalks, trees, bicycleparking, and site development, may apply to the development of this site. Unlessspecifically noted in the conditions for this site plan, these other standard developmentrequirements will be applied to the development of this site as defined by those othercity ordinances.

c. Throughout this Rezoning Petition, the terms "Owner", "Owners", "Petitioner" or"Petitioners," shall, with respect to the Site, be deemed to include the heirs, devisees,personal representatives, successors in interest and assignees of the owner or owners ofthe Site who may be involved in its development from time to time.

d. The total number of principal buildings to be developed on the Site shall not exceed 20.Accessory buildings and structures (as defined by the Zoning Ordinance) located on theSite shall not be considered in any limitation on the number of buildings on the Site.

2. Purpose

a. The purpose of this Rezoning application is to provide for the development of acommercial/industrial/warehouse park. To achieve this purpose, the application seeksthe rezoning of the site to the Industrial 1 (I-1(CD)) district.

3. Uses

a. Permitted Uses. Uses allowed on the property included in this Petition will be primaryand related accessory uses as are permitted in the I-1 district with the exception of thoselisted in b. Prohibited uses.

b. Prohibited uses.

i. Jails and prisons; Religious institutions; Adult establishment; Auction sales; Automobileservice stations; Automobiles, truck and utility trailer rental; Billboards; Commercialrooming houses; Flea market establishment; Hotels and motels; Homeless shelter;Overnight camping area; Beneficial fill site; Land clearing and inert debris landfill (LCID):off-site, mobile food vending services; Raceways and dragstrips; Crematory, within acemetery; Barber and beauty Shops; Financial institutions; Retail establishments;Shopping centers and business and recreation uses; Edee (Type I and II); Gas stations,with or without a convenience store; Personal services uses, and uses with an accessorydrive-through window; Amusement, commercial outdoors; Animal crematoriums;Armories for meeting and training of military organizations; Automotive repair garages;Automotive sales and repair; Bakeries, retail; Boat and ship sales and repair; Bus andtrain terminals; Car washes; Civic, social and fraternal facilities; Clinics, medical,dental,and optical; Clinics, veterinary; Dry cleaning and laundry establishments; Farms,including sales of products grown on premises; Heliports and helistops; Locksmiths andgunsmiths; Manufactured housing repair or sales; Orthotics - prosthetics facilities;Outdoors seasonal sales; Pest control and disinfecting services; Post offices; Recycling

centers, including drop-off centers; Tattoo establishment; Theaters, motion picture.

4. Transportation

a. The site will have access via drive connections to Shopton Road at the locationsprescribed by NCDOT & CDOT as generally identified on the concept plan for the site.

b. Petitioner will coordinate with NCDOT, CDOT, and Planning to improve the project'sShopton Road frontage, and to provide a road widening conforming to detail 3 on pageRZ-3 of this document.

c. Petitioner agrees to convey fee simple all the rights of way to the City of Charlotte priorto the issuance of the first building certificate of occupancy.

d. All transportation improvements will be approved and constructed prior to the issuanceof the first building certificate of occupancy.

e. Petitioner agrees to dedicate an 85' right of way to allow for the future extension ofShopton Road by others. The exact configuration of the 85' right of way may be subjectto adjustment in coordination with CDOT and the Petitioner during the site design andpermitting phase. Prior to the extension of Shopton Rd, the Petitioner may develop theright of way to Local Industrial Street standards, centered within the 85' right of way. Seedetail 5/RZ-3.

5. Architectural Standards

a. Building Placement and Site Design shall focus on and enhance the pedestrianenvironment on public or private network required streets, through the following:

i. Buildings shall present a front or side façade to all streets.

ii. Facades fronting streets shall include a combination of windows and operable doors fora minimum of 30% of each frontage elevation transparent glass between 2' and 10' onthe first floor. Up to 20% of this requirement may be comprised of display windows. Forindustrial and warehousing buildings, these standards shall apply only at the main entryand exterior office facades.

iii. Direct pedestrian connection should be provided between street facing doors frontingpublic access and corner entrance features to sidewalks on adjacent streets.

iv. Building elevations shall not have expanses of blank walls greater than 20 feet in alldirections. Architectural features such as but not limited to banding, medallions ordesign features or materials will be provided to avoid a sterile, unarticulated blanktreatment of such walls.

v. Building elevations shall be designed with vertical bays or articulated architecturalfeatures which shall include a combination of at least three of the following: acombination of exterior wall offsets (projections and recesses), columns, pilasters,change in materials or colors, awnings, arcades, or other architectural elements.

vi. Buildings should be a minimum height of 22' and maximum of 40.

6. Streetscape, Buffers, and Landscaping

a. Petitioner will coordinate with NCDOT, CDOT, and Planning to improve the project'sShopton Road frontage, and to provide a road widening conforming to detail 3 on pageRZ-3 of this document.

b. The Petitioner will provide a 100' undisturbed buffer along the site frontage withPinecrest Drive, planted as required to meet Class A buffer standards. The Petitioner will

provide a 50' Class A buffer along the Shopton Road frontage. Other buffers will beprovided as required by the Zoning Ordinance. The buffer may be reduced or eliminatedif abutting property is rezoned to a district or use that does not require a buffer.Petitioner will provide an additional no build zone at the north end of this site asdimensioned on RZ-2.

c. Development within the site will comply with City of Charlotte Tree OrdinanceRequirements.

d. A six (6) foot security fence will be installed on the eastern side of the buffer alongPinecrest Rd/Eagle Lake Dr as generally depicted on the rezoning plan.

7. Environmental Features

a. The Petitioner shall comply with the Charlotte City Council approved and adopted PostConstruction Stormwater Ordinance. The location, size, and type stormwatermanagement systems depicted on the rezoning plan are subject to review and approvalas part of the full development plan submittal and are not implicitly approved with thisrezoning. Adjustments may be necessary in order to accommodate the actualstormwater treatment requirements and natural site discharge points

b. Prior to construction permitting, the Petitioner will have a Preliminary WetlandsAssessment conducted on the property to identify possible locations of jurisdictionalwetlands and streams within the development area. Any proposed impacts will bepermitted as required through the appropriate agencies having jurisdiction.

c. All utilities within the Site will be placed underground.

d. The site shall be served by the Charlotte Water department for potable water andsanitary sewer utilities. No irrigation wells shall be permitted or constructed on the sitewithout permission of Mecklenburg County Land Use and Environmental ServicesAgency in order to avoid conflicts with possible nearby groundwater contamination sites.

8. Parks, Greenways, and Open Space

a. The Petitioner agrees to grant an easement within the site to Mecklenburg County Parksand Recreation, measured 100' from the top of bank along Coffey Creek, for the purposeof future extension of the Coffey Creek Greenway from Douglas Drive to Shopton Road.

b. The Petitioner agrees to provide up to two pedestrian connection easements (30' width)to the proposed Coffey Creek Greenway in locations generally depicted on RZ-2.

9. Fire Protection

a. All public streets within the proposed development will provide an 20' wide clear travelpath for the fire truck access. Any streets less than 26' pavement width will be prohibitedfrom on street parking.

10. Signage

a. Reserved

11. Lighting

a. Reserved

12. Phasing

a. Reserved

13. Binding Effect of the Rezoning Application

a. If this Rezoning Petition is approved, all conditions applicable to development of the Siteimposed under the Rezoning Plan will, unless amended in the manner provided underthe Ordinance, be binding upon and insure to the benefit of the Petitioner, current, andsubsequent owners of the Site and their respective successors in interest and assigns.

b. Throughout these Development Standards, the term “Petitioner” shall be deemed toinclude the heirs, devisees, personal representatives, successors in interest and assignsof Petitioner or the owner or owners of the Site from time to time be involved in anyfuture development thereof.

c. Any reference to the Ordinance herein shall be deemed to refer to the requirements ofthe Ordinance in effect as of the date this Rezoning Petition is approved.

1

1

1

1

APPROXIMATE

LOCATION EAGLE

LAKE GATE

BEGIN 6'

SECURITY

FENCE AT

GATE

2 02/15/18 MDH REVISIONS PER STAFF COMMENTS

2

NO DEVELOPMENT

PERMITTED IN THIS STRIP

2

2

30' SETBACK ALONG

SHOPTON RD

2

2

100' BUFFER CLASS

A UNDISTURBED

BUFFER

2

2

1

1

1

1

1

2

2

2

2

2

150' BLDG

SETBACK ALONG

EAGLE LAKE

DR/PINECREST DR

2

AutoCAD SHX Text
OHP
AutoCAD SHX Text
602
Page 2: EAGLE LAKE DRww.charmeck.org/Planning/Rezoning/2017/095-110/2017-097... · 2018-02-16 · sheet number: sheet # 1 of 3 project manager: drawn by: checked by: date: project number:

This Plan Is A

Preliminary Design.

NOT Released For

Construction.

P:\2

01

7 Jo

bs\1

70

26

- C

LT

S

ho

pto

n R

oa

d S

ite

\C

AD

\S

ke

tch

P

la

nn

in

g\1

70

26

B

AS

E.d

wg

0' 200' 400'

SCALE: 1"=200'

800'

Land

work

sDe

sign

Grou

p, P

.A.

7621

Littl

e Ave

nue,

Suit

e 111

Char

lotte

, NC

282

2670

4-84

1-160

4 f

ax: 7

04-8

41-16

04

Date By Description

REVISIONS:

No.

Sheet Number:

SHEET # 2 OF 3

Project Manager:

Drawn By:

Checked By:

Date:

Project Number:

MDL

MDL

SH

OP

TO

N R

OA

D S

IT

E

CH

AR

LO

TT

E D

OU

GLA

S

IN

TE

RN

AT

IO

NA

L A

IR

PO

RT

CH

AR

LO

TT

E, N

C

05/22/17

17026

MDH

RZ-2

CORPORATE CERTIFICATIONS

NC PE : C–2930 NC LA : C–253

SC ENG : NO. 3599 SC LA : NO. 211

SHOPTON RD

(SR 1155)

P

IN

E

C

R

E

S

T

D

R

WATER

QUALITY

WATER

QUALITY

WATER

QUALITY

WATER

QUALITY

WATER

QUALITY

FEMA FLOODPLAIN

E

X

I

S

T

I

N

G

P

O

W

E

R

L

I

N

E

R

/

W

100' CLASS A

UNDISTURBED

BUFFER

50' BUFFER

REZONING

SITE PLAN

REZONING PETITION:

2017-97

EASEMENT FOR COFFEY CREEK

GREENWAY EXENSION(100' FROM

TOP OF BANK)

WATER

QUALITY

WATER

QUALITY

1

0

0

'

T

Y

P

E

A

B

U

F

F

E

R

5

7

'

T

Y

P

E

B

B

U

F

F

E

R

W

/

F

E

N

C

E

R/W FOR FUTURE

ROAD CONNECTION

P

C

O

S

W

IM

B

U

FF

E

R

(T

Y

P

)

C

O

F

F

E

Y

C

R

E

E

K

SWIM BUFFER

(TYP.)

1 1/12/18 MDH REVISIONS PER STAFF, COMMUNITY & PETITIONER

COMMENTS

A

A'

SE

E S

H

EE

T R

Z-3

BLDG, PKG TRUCK

LOADING ZONE

BLDG, PKG TRUCK

LOADING ZONE

BLDG, PKG TRUCK

LOADING ZONE

BLDG, PKG TRUCK

LOADING ZONE

BLDG, PKG TRUCK

LOADING ZONE

BLDG,

PKG

TRUCK

LOADING

ZONE

ROAD TYPE 1

(SEE RZ-3)

BLDG, PKG TRUCK

LOADING ZONE

E

A

G

LE

LA

K

E

D

R

COFFEY CREEK

BRIDGE (BY

OTHERS - SEE RZ-3)

ROAD TYPE 1

(SEE RZ-3)

ROAD TYPE 1

(SEE RZ-3)

VOLUNTARY

NO BUILD

ZONE/TREE

SAVE

POSSIBLE FUTURE

GREENWAY

ACCESS

EASEMENT

30' GREENWAY

CONNECTOR #1

2

5

0

'

M

I

N

5

0

0

'

M

A

X

30' GREENWAY

EASEMENT

CONNECTOR #2

LEGEND

EXISTING CONTOUR

SWIM BUFFER

POSSIBLE GREENWAY EASEMENT

PROPERTY LINE

DEVELOPMENT AREA

OVERHEAD POWER

VOLUNTARY TREE SAVE

1

1

1

1

1

1

1

1

1

1

R

2

0

0

'

1

2

SE

C

TIO

N

LIN

E

2

DEDICATED ROW (57' FROM

EX CL OF SHOPTON RD)

EXISTING ROW

2

2

2 02/15/18 MDH REVISIONS PER STAFF COMMENTS

BLDG, PKG TRUCK

LOADING ZONE

ROAD TYPE 2

(SEE RZ-3)

ROAD TYPE 2

(SEE RZ-3)

2

2

30' SETBACK FROM PROP

ROW

100' CLASS A

UNDISTURBED

BUFFER

2

2

N

150' BLDG

SETBACK ALONG

EAGLE LAKE

DR/PINECREST DR

AutoCAD SHX Text
OHP
AutoCAD SHX Text
602
Page 3: EAGLE LAKE DRww.charmeck.org/Planning/Rezoning/2017/095-110/2017-097... · 2018-02-16 · sheet number: sheet # 1 of 3 project manager: drawn by: checked by: date: project number:

CL

0+00

632.4

632.4

1+00

634.0

634.0

2+00

634.0

634.0

3+00

634.9

634.9

4+00

652.1

652.1

5+00

666.6

666.6

6+00

676.9

676.9

7+00

682.5

682.5

8+00

689.3

689.3

9+00

692.7

692.7

10+00

694.3

694.3

11+00

696.6

696.6

12+00

696.5

696.5

13+00

694.4

694.4

14+00

690.1

690.1

15+00

683.0

683.0

16+00

672.8

67

2.8

17+00

65

7.8

657.8

610

620

630

640

650

660

670

680

690

700

710

This Plan Is A

Preliminary Design.

NOT Released For

Construction.

P:\2

01

7 Jo

bs\1

70

26

- C

LT

S

ho

pto

n R

oa

d S

ite

\C

AD

\S

ke

tch

P

la

nn

in

g\1

70

26

B

AS

E.d

wg

Land

work

sDe

sign

Grou

p, P

.A.

7621

Littl

e Ave

nue,

Suit

e 111

Char

lotte

, NC

282

2670

4-84

1-160

4 f

ax: 7

04-8

41-16

04

Date By Description

REVISIONS:

No.

Sheet Number:

SHEET # 3 OF 3

Project Manager:

Drawn By:

Checked By:

Date:

Project Number:

MDL

MDL

SH

OP

TO

N R

OA

D S

IT

E

CH

AR

LO

TT

E D

OU

GLA

S

IN

TE

RN

AT

IO

NA

L A

IR

PO

RT

CH

AR

LO

TT

E, N

C

05/22/17

17026

MDH

RZ-3

CORPORATE CERTIFICATIONS

NC PE : C–2930 NC LA : C–253

SC ENG : NO. 3599 SC LA : NO. 211

REZONING

SECTIONS

REZONING PETITION:

2017-97

1 1/12/18 MDH REVISIONS PER STAFF, COMMUNITY & PETITIONER

COMMENTS

PROPOSED BLDG

EAGLE LAKE DR

(ELEVATION 696 FT)

100' BUFFER

EXISTING EAGLE LAKE

(ELEVATION ±634)

APPROXIMATE LOCATION OF

EXISTING HOME(ELEVATION 659 FT)

EXISTING TREES (TYP.)

EXISTING GRADE (DASHED)PROPOSED GRADE (SOLID)

SECTION A - A'

SCALE: 1" = 60'

12.0'11.0'11.0'11.0'12.0'

1.5' 2.5'2.0'

2.5' 1.5'2.0'

70' R/W

BRIDGE RAILING (TYP).

SIDEWALK

CURB AND

GUTTER (TYP.)

TRAVEL LANETURN LANETRAVEL LANESIDEWALK

65.0' R/W

5.0'8.0'

2.5'

15.0'15.0'

2.5'

8.0'5.0'

SIDEWALK

PLANTING

STRIP

CURB &

GUTTER

TRAVEL LANETRAVEL LANE

PLANTING

STRIP

SIDEWALK

CURB &

GUTTER

MEDIAN

TRAVEL LANE TRAVEL LANE BIKE LANE

PLANTING

STRIP

SIDEWALK

57.0'

6.0'8.0'

2.5'

8.0'11.0'11.0'6.0'

686' 200'

CONCEPTUAL BLDG

(30' HEIGHT SHOWN FOR REFERENCE)

FUTURE IMPROVEMENT BY OTHERS

POSSIBLE

BLDG ELEV. 681 FT

EXISTING EAGLE LAKE DRIVE 100' UNDISTURBED BUFFER

EXISTING GRADE(DASHED)

CONCEPTUAL GRADING (SOLID)

ENLARGEMENT

1

RZ-3

ENLARGEMENT

SCALE: 1" = 10'

1

RZ-3

ROADWAY IMPROVEMENT - EXISTING SHOPTON ROAD(PROPERTY FRONTAGE ONLY)

SCALE: 1" = 10'

2

RZ-3

ROAD TYPE 1 - LOCAL INDUSTRIAL

SCALE: 1" = 10' CLDSM U-06

3

RZ-3

COFFEY CREEK BRIDGE - BY OTHERS (FOR REFERENCE ONLY)

SCALE: 1" = 10'

4

RZ-3

PR

OP

OS

ED

R

OW

EX

IS

TIN

G C

L

2.5'

1

EAGLE LAKE OWNED C.O.S.

2' S.U.E.2' S.U.E.

2

2 02/15/18 MDH REVISIONS PER STAFF COMMENTS

85.0' R/W

5.0'8.0'

2.5'

15.0'15.0'

2.5'

8.0'5.0'

SIDEWALK

PLANTING

STRIP

CURB &

GUTTER

TRAVEL LANETRAVEL LANE

PLANTING

STRIP

SIDEWALK

CURB &

GUTTER

ROAD TYPE 2 - LOCAL INDUSTRIAL WITH R/W EXPANSION

SCALE: 1" = 10' CLDSM U-06

5

RZ-3

2' S.U.E.2' S.U.E.

2

150' MIN BLDG SETBACK (ALONG EAGLE LAKE DR AND PINECREST DR)

2

2