Two profiles available to fit: 50-100mm cavities & 100-150mm cavities Fully Rigid Plastic Cavity Closer Easy Fit Insulated Cavity Closer Fully certificated Meets building regulations Available in two profiles to fit up to 150mm cavity Minimum thermal resistance 0.967m 2 K/W Easily cut to fit the exact cavity size Fully rigid plastic cavity closer 50 65 75 85 100 150 115 F i v e W i d t h s i n o n e C a v i t y C l o s e r 5 T w o P r o l e s M a x i m u m w i d t h 1 5 0 m m 2 C u t G r o o v e s t o d e s i r e d w i d t h 100mm 85mm 75mm 65mm 50mm SILVER

Upload: others

Post on 05-Mar-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Easy Fit Insulated Cavity Closer - YBS Insulation€¦ · Easy Fit Insulated Cavity Closer • Fully certificated • Meets building regulations • Available in two profiles to fit

Two profiles available to fit: 50-100mm cavities & 100-150mm cavities

Fully Rigid Plastic Cavity Closer

Easy Fit Insulated Cavity Closer

• Fully certificated

• Meets building regulations

• Available in two profiles to fit up to 150mm cavity

• Minimum thermal resistance 0.967m2K/W

• Easily cut to fit the exact cavity size

• Fully rigid plastic cavity closer

50 65 75 85 100

150115

Five Widths

in one Cavity C

lose

r5

Two Profi les

Maxim

um width 1

50m

m2

Cut Grooves

to desired width

100mm

85mm

75mm

65mm

50mm

SILVER

Page 2: Easy Fit Insulated Cavity Closer - YBS Insulation€¦ · Easy Fit Insulated Cavity Closer • Fully certificated • Meets building regulations • Available in two profiles to fit

YB

S V

1 01

/201

5

Yorkshire Building Services (Whitwell) Ltd, Crags Industrial Park, Morven Street, Creswell, Derbyshire, S80 4AJT: +44 (0) 844 99 100 44 F: +44 (0) 844 99 100 55

E: [email protected] W: www.ybsinsulation.com

© Yorkshire Building Services (whitwell) Ltd.

=

Vertical Jointing

If required, sections of Easi-Close can be jointed to minimise waste. All joints must be tightly butted -450 downwards towards the outer leaf. This will stop potential water penetration.

Corner Jointing

When jointing horizontal to vertical, trim both PVC flanges and allow the vertical to extend below the horizontal - this stops water ingress.

Measure cavity opening

Cutprofile to

required length

Measure the opening of window/door

1 2 3

Two profiles available to fit: 50-100mm cavities & 100-150mm cavities

Press the insulation side of the profile into the opening, fixing the plastic flange securely with clout nails or a grab adhesive.

5Cut insulation to required width. DO NOT CUT THE PLASTIC OUTER SHELL (2 profiles, max. cavity width 150mm)

450 65 75 85 100

150115

BDA Agrément Nr.BPD 11-304 • BPD 11-305

BPD 11-306

Minimum thermal resistance of path 2 (shortest path) - Standard

Exceeds building regulations minimum thermal resistance path of 0.45 m2K/W

The declared minimum thermal resistance for the defined cavity closer 0.930 (EPS)

Figure Path Distancemm

Material

EPS

A - B1 1,6 0,0090,170U-PVC

B1 - C1 29,0 0,9060,032XPS or

EPS

C1 - E 1,0 0,0060,170U-PVC

E - F 1,6 0,009

0,930Rmin =

0,170U-PVC

Thermalconductivity(W.m-1.K-1)

Thermal resistance(m2.K.W-1)

Easi-Close can be installedin a variety of ways:

• Tack to window frame if built in.

• Built-in as work progresses friction fitting.

• Easi-Close can be installed after the reveal has been constructed by fixing to the inner leaf using grab adhesive.

Five Widths

in one Cavity C

lose

r5

Two Profi les

Maxim

um width 1

50m

m2Cut G

rooves

to desired width