easy, reliable, accurate: dose area product meters by...
TRANSCRIPT
Easy, reliable, accurate:Dose Area Product meters by PTW
DIAMENTOR® Systems by PTWPTW is setting a worldwide standard with the DIAMENTOR systems for patientdosimetry in diagnostic radiology.
PTW-FrancePTW-France
PTW-New YorkPTW-New York
AustraliaAustralia andNew Zealand
EuropeAustriaBelarus BelgiumBulgariaCyprusCzech Republic
DenmarkFinlandFranceGermanyGreeceHungaryIcelandItalyMaltaNetherlandsNorway
Poland PortugalRomaniaRussiaSlovakiaSpainSwedenSwitzerlandTurkeyUkraineUnited Kingdom
AsiaBahrainBangladeshChinaHong KongIndiaIndonesiaIranIsraelJapanJordan
KoreaLebanonMalaysiaPakistanPhilippinesSaudi ArabiaSingaporeSyriaTaiwanThailandVietnam
ColombiaCosta RicaEcuadorMexicoPanamaUruguayUSAVenezuela
AfricaEgyptMoroccoSouth Africa
AmericaArgentinaBrazilCanadaChile
PTW-FreiburgPTW-Freiburg
PTW-Latin AmericaPTW-Latin America
PTW-ChinaPTW-China
Physikalisch-Technische WerkstättenDr. Pychlau GmbH
PTW-FreiburgLörracher Strasse 779115 Freiburg · GermanyPhone +49 761 49055-0Fax +49 761 [email protected] www.ptw.de
PTW-New York Corporation201 Park AvenueHicksville · New York 11801Phone (1-516) 827 3181 Fax (1-516) 827 [email protected]
PTW-France SARL41 Chemin de la Cerisaie91620 La Ville du Bois · France Phone +33 1 64 49 98 58Fax +33 1 69 01 59 [email protected]
PTW reserves the right to modify the design and specifications contained herein without prior notice. Please contact PTW or your local representative for themost current information.
D150.139.0/0 200602-3BPrinted on cellulose bleached by a non-polluting method.
PTW-Latin AmericaAv. Evandro Lins e Silva840 Sala 2018 · Barra da Tijuca22631-470 Rio de Janeiro-RJ · BrazilPhone +55 21 2178 2188 Fax +55 21 2429 [email protected]
PTW-ChinaUnit 2018, 20/F., Shatin Galleria18-24 Shan Mei Street, Fotan, N.T.Hong KongPhone +852 3156 4991Fax +852 3156 [email protected]
Easy to use: The user friendly design of the DIAMENTOR devices byPTW-Freiburg ensures easy handling. Optimally coordinatedcomponents enable the user to install the systmes convenientlyand fast.
Knowing what responsibility means:
Accurate: PTW-Freiburg is the pioneer of the DAP meter. DIAMENTOR measuring systems are top-rate German products for radiation protection,which have been supplied in quantities of many thousands to satisfiedcustomers.
Reliable: PTW-Freiburg DAP meters are the most reliable DAP meters onthe market. The fact that DIAMENTOR systems installed 30 years ago arestill working accurately documents the unique reliability of productsfrom PTW-Freiburg.
DIAMENTOR® is a registered trademark of PTW-Freiburg
What is the dose area product (DAP)?
The DAP is the result of the multiplication of the entrance dose (air kerma)and the area of the beam. It can be measured by a flat ionization chamberwhich is mounted directly to the light beam housing between the X-rayfocus and the patient surface. Following the inverse square law, the DAPis independent of this distance between focus and patient.This relationship indicates that doubling the distance between a radiationsource and a measuring chamber increases the radiation area by a factorof four, while the dose (air kerma) decreases simultaneously by a factor offour. Both effects cancel out each other. Therefore the dose area productis independent of the distance and it determines in an elegant way allvariable parameters like tube voltage, tube current, filtration, irradiationtime and field size during an examination.
PTW DIAMENTOR systems are setting a worldwide standard
4 5
There is no interference with routine work, since the ionization chambers are firmly mounted to the collimator.
The highly transparent ionization chambers ensure proper operation of the light system.
Optimally coordinated components enable convenient and fast installations.
Fast calibration and constancy checks can be performed by means of a built-in test function.
Easy and uncomplicated RIS or HIS connection can be realized straightforward via the RS232 interface.
The user friendly design of the devices ensures easy handling.
Uncomplicated and easy evaluation of the total amount of radiation applied to patients.
For more than 40 years, PTW-Freiburg has worked success-fully in developing and manufacturing DAP meters for dia-gnostic radiology, which are manufactured in line with thestrictest quality standards and completely fulfill therequirements of IEC 60580 and FDA 21 CFR Part 1020.
Application areas:
radiography
fluoroscopy
angiography, DSA, cardiological series
interventional radiography
What are the advantages of a DIAMENTOR system?
[1] Council Directive 97/43/EURATOM of 30 June 1997 on health protection of indi-viduals against the danger of ionizing radiation in relation to medical exposure[2] USA Food and Drug Administration (FDA), Federal Register Part III, Departmentof Health and Human Services – 21 CFR Part 1020 (Electronic Products; Performan-ce Standard for Diagnostic X-Ray Systems and Their Major Components; Final Rule)[3] IEC 60580 Medical electrical equipment – Dose area product meters
The use of radiation in medicine is of great value,but it contributes by far the greatest part of the man-maderadiation dose. Especially diagnostic radiology delivers thehighest share of radiation exposure to the population.
Radiation protection procedures are therefore mandatory in many countries such as the countries of the European Community and the USA. A European Directive requires the“assessment and evaluation of patient doses” [1]. Accordingto a publication of the Food and Drug Administration (FDA)[2], fluoroscopic equipment manufactured on or after June10, 2006, must display at the fluoroscopist’s working positionthe air kerma rate (AKR) and the cumulative air kerma.According to clause 1020.32(k) of this publication, a fluoro-scopic air kerma display device signifies a device that providesthe display of AKR and the cumulative air kerma – such asthe DIADEM patient dosemeter from PTW-Freiburg.
Diagnostic The use of radiation in medicine is of great value,but it contributes by far the greatest part of the man-maderadiation dose. Especially diagnostic radiology delivers thehighest share of radiation exposure to the population.
Radiation protection procedures are therefore mandatory in many countries such as the countries of the European Community and the USA. A European Directive requires the“assessment and evaluation of patient doses” [1]. Accordingto a publication of the Food and Drug Administration (FDA)[2], fluoroscopic equipment manufactured on or after June10, 2006, must display at the fluoroscopist’s working positionthe air kerma rate (AKR) and the cumulative air kerma.According to clause 1020.32(k) of this publication, a fluoro-scopic air kerma display device signifies a device that providesthe display of AKR and the cumulative air kerma – such asthe DIADEM patient dosemeter from PTW-Freiburg.
Dose area product (DAP) meters and dosemeters, firmlyinstalled to the X-ray unit, make it possible to determine theradiation load to which patients are exposed during X-rayexaminations. The exposures can be reduced by a measuringdevice informing the practitioner of the total amount ofradiation applied to the patient. Especially high dose andhigh risk X-ray examinations such as fluoroscopy require adevice to determine the radiation exposure to patients.
Measuring devices of the DIAMENTOR series and the DIADEMpatient dosemeter provide for patient dosimetry solutionscovering every application and budget and help to protectpatients against the risk of radiation exposure in medicaldiagnostic radiology.
DIAMENTOR® E2 DIAMENTOR® C2 DIAMENTOR® M4
DIAMENTOR systems
specially suitable for mobile and stationaryinstallations
perfect for C arms
perfect for stationary installations
simultaneous DAP measurement on twodifferent X-ray installations are possible(perfect if the control desk is the same)
prized for biplane angiography
suitable for stationary installations
prized for biplane angiography
T11033 consists of:
DIAMENTOR E2
T11038AP consists of:
DIAMENTOR C2 with a printer
T11038A consists of:
DIAMENTOR C2 without printer
T11024 consists of:
DIAMENTOR M4
Wall fixation parts
bright LED display
easy connection to a RIS or HIS via theinternal RS232 interface
well-priced system
multifunctional dual channel DAP meter
separate channels; separate value printingand separate resetting is possible
easy connection to a RIS or HIS via theinternal RS232 interface
with or without internal printer available
multifunctional dual channel DAP meter
easy connection to a RIS or HIS via the internal RS232 interface
secondary display can be connected on demand
... have a DIAMENTOR solution with an internal printer and with theopportunity to connect two ionizationchambers?
... have a DIAMENTOR solution wheretwo ionization chambers can be connected?
... have a well-priced and flexibleDIAMENTOR solution with integratedelectronics and display unit for connecting one ionization chamber?
6 7
DIAMENTOR® CX DIAMENTOR® Set CI DIAMENTOR® Set CMcompact DAP meter with a bright LEDdisplay
fast and simple installation
easy connection to a RIS or HIS via anoptional RS232 module
integrated electronics
flexible LED display positioning
easy connection to a RIS or HIS via an optional RS232 module
well-priced system
flexible positioning of the small electronics
flexible LED display positioning
easy connection to a RIS or HIS via an optional RS232 module
well-priced system
specially suitable for mobile andstationary installations
display can be fixed arbitrary electronics can be hidden behind the hou-sing of the X-ray installation
display can be fixed arbitrary e.g. next tothe control desk
L981961 consists of:
DIAMENTOR CX
Power supply
L981196 consists of:
DIAMENTOR CI
DIAMENTOR CD display
Power supply
Extension cable
L981197 consists of:
DIAMENTOR CM
DIAMENTOR CD display
Ionization chamber B
Power supply
Extension cable
Application
Ordering Information
„... have an "all-in-one" DIAMENTORsystem with integrated ionizationchamber, electronics and display unit?
... have a well-priced DIAMENTORsystem with a separate display unitbut integrated electronics and ionization chamber?
... have a well-priced DIAMENTORsystem with a separate ionizationchamber type B, a separate displayunit and separate electronics?
Find out which DIAMENTOR system is the right one. Would you like to ...
yes
no
yes yes yes yes yes
no no no no no
DIAMENTOR® M4-KDK DIADEM® DIAMENTOR®
built-in solution
suitable for stationary installations
exquisite for applications where dose anddose rate values are also required
specially suitable for mobile and stationaryinstallations
circular ionization chambers for C arms areavailable
narrow ionization chambers for mobile application are available
well-priced, non-transparent ionizationchambers for under couch tubes are available
T11039 consists of:
DIADEM
Built-in DIAMENTOR DAP meters uponrequest!
Please contact us!
measures simultaneously DAP, DAP rate,dose and dose rate
special KDK chamber with two measuringareas
easy connection to a RIS or HIS via theinternal RS232 interface
secondary display can be connected ondemand
fulfills the requirements acc. to FDA 21 CFRPart 1020
measures simultaneously dose and doserate
fullfills the requirements acc. to FDA 21CFR Part 1020
different built-in DIAMENTOR DAP metersare available, which have been developed incooperation with well known manufacturersof X-ray installations
many different ionization chambers areavailable
“...have a device that measures theDAP, the DAP rate as well as the dose,the dose rate and the irradiation timevia an ionization chamber directlymounted to the collimator?
...have a device that measures only the dose and dose rate via an ionizationchamber directly mounted to the collimator?
...have a built-in solution?
8
yes yes yes
no no
overview
T11025 consists of:
DIAMENTOR M4-KDK
Wall fixation parts
Technical dataDIAMENTOR in combination with a standard B chamber M4-KDK DIADEM with
CX CI CM E2 C2 M4 with KDK chamber DIADEM chamber
Product Channels one channel device dual channel device one channel device one channel device
Measuring unit DAP [µGym2] X X X X X X X
DAP rate [µGym2/s] X X X X X X X
Dose [mGy] X X
Dose rate [mGy/s] X X
Irradiation time [s] X X
Measuring range DAP (0.1 ... 99 999 999) µGym2 (0.1 ... 999 999) µGym2
DAP rate (0.1 ... 15 000) µGym2/s (0.1 ... 30 000) µGym2/s
Dose (0.01 ... 10 000) mGy (0.1 ... 99 999 999) mGy
Dose rate (0.01 ... 999 999) mGy/s (0.1 ... 15 000) mGy/s
Irradiation time 1s ... 999 min
Digital resolution DAP 0.01 µGym2
DAP rate 0.01 µGym2/s
Dose0.001 mGy for (0.01... 999 999) mGy
0.01 mGy1 mGy for (1000 ...10 000) mGy
Dose rate 0.001 mGy/s 0.01 mGy/s
Irradiation time600 ms (Dose rate > 2.4 µGy/s) 60 ms (Dose rate > 12 µGy/s)
Ranges of use DAP rate (0.01 ... 15 000) µGym2/s (0.005 ... 30 000) µGym2/s
Dose rate: (0.005 ... 15 000) mGy/s
Tube voltage (50 ... 150) kV
Temperature (10 ... 40) °C
Air density* (10 ... 80) %, max. 20 g/m3
Display LED LCD LED
Power supply 24 VDC ± 10%(100 ... 240) VAC, 230 V / 115 V
(50 ... 60) Hz AC voltage 24 VDC ± 10%
Dimension [H x W x D] 164 x 209 x 18 mm3 164 x 220 x 18 mm3 52 x 72 x 22 mm3 36 x 83 x 151 mm3 104 x 264 x 186 mm3 71 x 225 x 198 mm3 36 x 83 x 151 mm3
Weight 325 g 330 g 105 g 250 g 1180 g 2100 g 250 g
Do you have any other questions?Please contact us!
*without condensation
> 0.04 µGym2 / s: 600 ms> 0.2 µGym2 / s: 60 ms
DIAMENTOR accessories installation
(Distance) adaptation rails(distance) adaptation rails can be screwed directly to the ionizationchamberdistance adaptation rails facilitate the use of fade out filtersUniversal holdereasy and flexible handlingadjustment of rail distances between 133 mm and 177 mm arepossibleoptional rails for the use of ovarian filters are availableallows the correct arrangement of any filter and the chamberwithout influencing the measurementPediatric filterstransparent filters for reducing the patient entrance dose duringpediatric X-ray examinationdifferent filter sizes with different beam hardening values are availabledo not influence the light fieldExternal printersused in combination with a DIAMENTOR M4-KDK, M4, E2 andDIADEMprinting is automatically controlled by the DIAMENTOR unitconnection via the RS232 interface
Secondary displayfor use with a DIAMENTOR M4-KDK or M4 flexible positioningbright LCD display
DiaSoft softwarefor use with a DIAMENTOR M4-KDK, M4 or C2calculates the effective dose and the organ doses from the DAPpresents the results as a function of time graphicallyPower limitationideal for mobile installations, which fulfill IEC 60601-1operation with 24 Vfor use with a DIAMENTOR CX, CI, CM or E2small and convenient solution
CE marked
Extension cabledifferent lengths are availablenormally a 15 m extension cable is sufficient
Installation
Run the extension cable
Connect the power supply
Put the chamber into the rails of the collimator
Connect the components
Make at least a test measurement
DAP installations: quick and easy with PTW DIAMENTORsystems, also on C-arms and mobile X-ray installations
10 11
secondary display
printer pediatric filters attach chamber
insert universal holder
connect components built-in solution
Make a test measurement
Knowing what responsibility means:
12 13
In 1922, twenty-seven years after Röntgen discovered X-rays, Professor Hammer from the Physics Institute of Freiburg University founded PTW to produce and markethis development of an X-ray dosemeter based on an electrostatic relay, a revolutionary new electromechanicalcomponent for measuring very small electrical charges.
In 1927, Dr. Herbert Pychlau took over the company anddeveloped it during four decades into an internationallyrecognized manufacturer of quality dosemeters for medicalradiology.
During the second half of the 20th Century, the businessgrew into an acknowledged international company, acquiring a good reputation as a pioneer with both scientists and users.
PTW-Freiburg’s production area, which in the very beginning was located in Professor Hammer’s gardenshed, covers a total area of 4000 m2 today. PTW employs a staff of 200 all over the world. The company, which scores steady growth, is the recognized market leader in medical dosimetry today.
We at PTW constantly strive to be competent and reliablepartners for our customers all over the world, which includes maintaining demanding quality standards aswell as comprehensive service and support standards. We will continue our efforts to develop the most reliableand highest quality dosimetry products in the future aswe have in the past, products in which users and patientsput their trust.We are committed to upholding this trust, because weknow what responsibility means.
The Directors Dr. Christian Pychlau and Dr. Edmund Schületogether with Günter Hein, Director of Sales and Marketing(from left).