eaton powerware

Upload: mauricio-cesar-molina-arteta

Post on 06-Jul-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/18/2019 Eaton powerware

    1/6

    provides 60-day notification o

    the end of useful life for the b

    teries.

    The Powerware 9120’s com-

    munications are flexible,allowing for local, network or

    remote monitoring and man-

    agement. The Powerware 912

    includes the latest version of

    the Powerware Software Suit

    which provides power monito

    ing and shutdown software.

    Simple plug-and-play operati

    makes installing the Powerwa

    9120 fast and easy. A single b

    ton touch provides clean, uni

    terruptible power to the critic

    load. An intuitive LCD screen

    provides real-time updates of

    UPS status, power usage, bat

    tery runtime remaining, and

    other critical UPS parameters

    With the Powerware 9120, Ea

    delivers a best-in-class powe

    solution for maximum system

    availability, and peace of min

    As businesses become increas-

    ingly dependent on technology

    for their fundamental operation,

    the need for system availability

    is of paramount importance.

    The Powerware 9120 UPS isdesigned for those applications

    that need maximum protection

    in the 700 VA – 3 kVA range.

    With its high-frequency, double-

    conversion online topology, pro-

    viding nonstop clean sine wave

    power, advanced communica-

    tions and space-saving tower

    design, the Powerware 9120 is

    the ideal solution for networks,

    web servers, telecommunica-

    tions applications and other

    critical electronic equipment.

    In addition to its proven design,

    the Powerware 9120 offers

    Advanced Battery Management

    (ABM)® and sophisticated com-

    munications to provide maxi-

    mum system availabil ity. ABM

    uses a three-stage charging

    technique that not only doubles

    battery service life, but opti-

    mizes battery charge time and

    Features • True double-conversion online technology gives you protec-

    tion from all nine power problems

     • Simple installation and operation

     • Intuitive LCD screen provides real-time updates of UPS status,

    power usage, battery runtime remaining and other critical UPS

    parameters

     • Hot-swappable batteries

     • Extended runtime capability with external battery modules

     • Complete offering of power management software included

    to ensure data integrity

     • User-selectable High Efficiency Mode

     • Provides investment protection with a two-year limited

    warranty, 10-year pro-rated warranty, $250,000 load protectionguarantee (U.S. and Canada)

    Product Snapshot

    Power Rating: 700-3000VA

    Voltage: 120 and 230 Vac

    Frequency: 50/60 Hz(auto-sensing)

    Configuration: tower

    Powerware® 9120Uninterruptible Power SystemProduct Focus

  • 8/18/2019 Eaton powerware

    2/6

    Series 9 PowerProtection

    True Online Design

    True online systems such

    as the Powerware 9120 are

    the only type of UPSs that

    completely isolate con-

    nected equipment from all

    nine of the most common

    power problems:

    Even when presented

    with the most severe of

    these power problems, the

    Powerware 9120 output

    remains within a remark-

    able ±2% of nominal volt-

    age, meaning that your

    critical system always

    receives clean power. In

    addition, the Powerware

    9120 transfers to battery

    with no break in power,

    making it the perfect UPS

    for equipment in environ-

    ments plagued by poor

    power.

    Power Failures

    Power Sags

    Power Surges

    Undervoltage

    Electrical

    Line Noise

    Overvoltage

    Frequency

    Variation

    Switching

    Transient

    Harmonic

    Distortion

    Powerware 9120 Features

    Starts up/Shuts

    down the UPS

    Scroll meters/

    Select UPS settings

    Scroll UPS settings/

    Select UPS setting param-

    eter

    LCD

    Front Panel Display

    Informative user interface with LCD, four LED and audible alarms.

    Loads Segments, Network Transient Protector andRemote Emergency Power Off (REPO) Port

    Load Segments are groups of receptacles

    that can be independently controlled and

    extend battery backup times for critical

    equipment.

    To preserve battery power for more critical

    equipment connected to Load Segment 1,

    shut down Load Segment 2 supporting less

    critical equipment.

    Shut down and power up Load Segments in

    user-defined sequence.

    The Network Transient Protector isolates

    your modem, fax machine, and other elec-

    tronic equipment from “back door” power

    surges.

    The REPO port enables you to shut

    down the UPS and connected equipment

    from a remote location in an emergency.

    1

    23

    4

    1 UPS On

    2 On Battery

    3 On Bypass

    Powerware

    9120 1000 Shown

  • 8/18/2019 Eaton powerware

    3/6

    Hot-Swappable Batteries

    You can hot-swap batteries without powering down the critical load. This makes it possible to extend

    the life of your UPS without returning the unit for service.

    Extended Battery Modules (EBMs)

    Increasing battery backup time is as simple as plugging in an extended battery module. Hot-swap ca

    bility on all Powerware 9120 models allows you to expand runtime or replace battery modules while

    keeping your critical load up and running.

    Advanced Battery Management (ABM) Technology Doubles Battery Service Life

    Battery Features and Runtimes

    The lead-acid batteries typically used in a UPS are considered viable

    as long as they can maintain backup time of at least half that of new

    batteries. The illustration below to the right shows that batteries that

    are constantly trickle charged (as are virtually all other UPS batteries

    on the market today) reach the end of their useful life in less than

    half the time of batteries charged using ABM. ABM uses a three-

    stage charging technique that not only doubles battery service life,

    but also optimizes battery recharge time and provides advanced noti-

    fication of the end of useful battery life.Data based upon tests performed by an independent

    battery manufacturer

    Powerware 9120 - 1000 VA shown

    with front cover removed and bat-

    tery shown sliding out.

    BATTERY RUNTIME CHART (IN MINUTES FULL LOAD/HALF LOAD)*

    VA Standard Internal Battery 1 EBM 2 EBMs 3 EBMs 4 EBMs 5 EBMs

    700 7/18 34/70 64/140 — — —

    1000 7/18 36/80 66/155 — — —

    1500 7/18 29/67 56/130 — — —

    2000 12/34 49/107 93/195 140/310 192/403 240/504

    3000 6/15 30/70 57/128 87/191 120/264 148/325

    *Up to 2 EBMs can be connected to 700/1000/1500 VA models and up to 5 EBMs can be connected to 2000/3000 VA models. Runtime chart provides typical informa- tion. Runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.

  • 8/18/2019 Eaton powerware

    4/6

    Communications

     • USB port (standard) allows UPS to communicate with Windows 98 and ME computers

     • RS232 Port (standard) for interface with power management software

     • SNMP/Web card (optional) adds direct control and monitoring capabilities in SNMP-basednetworks. Ability to monitor UPS status and meters through Web browser interface

     • Relay card (optional) adds integration to industrial environment and building management

    systems, shutdown for IBM AS/400.

    S O F T W A R E S U I T E

    LanSafe III &

    CheckUPSNetwork Shutdown

    for UPSs

    LanSafe III &CheckUPS

    Network Shutdownfor UPSs

    OnliNetSNMP-Based

    Network Shutdown& Monitoring

    OnliNetSNMP-Based

    Network Shutdown& Monitoring

    ForeseerFacility & DataCenter Management

    ForeseerFacility & Data

    Center Management

    ForeseerFacility & Data

    Center Management

    LanSafe III &

    CheckUPSNetwork Shutdown

    for UPSs

    PowerVisionUPS Performance

    Analysis &Monitoring

    PowerVisionUPS Performance

    Analysis &Monitoring

    PowerVisionUPS Performance

    Analysis &Monitoring

    OnliNetSNMP-Based

    Network Shutdown& Monitoring

    Powerware Software Suite

    The industry’s most comprehensive software bundle, the Powerware Software Suite CD, is free and

    included with every Powerware 9120 UPS.

     • Software Wizard guides you through software selection and installation

     • In addition to multimedia demonstrations, product data sheets, and video clips, the Software Suite

    contains the following power management software:

      – LanSafe® III and CheckUPS network shutdown for UPSs

      – OnliNet® software (Lite / Vista / Centro): SNMP-based network shutdown and monitoring for UPSs

      – PowerVision® software (30-day trial version): UPS performance analysis and monitoring

      – Foreseer® software (demonstration): Facility and data center management

    Software and Connectivity Options

    SNMP/Web Card shown

    PW9120 1000, 120V

    Rear Panels: 120V, 208V and 230V Models

    Four IEC-C13Receptacles

    USB Port

    CommunicationPort

    Fan

    NetworkTransientProtector

    Communication Slot

    REPO Port

    BatteryConnector

    IEC-C14 InputConnector

    PW9120 3000, 120V PW9120 3000, 208V PW9120 700i/1000i, 230V PW9120 1500i, 230V

    PW9120 700, 120V PW9120 1500, 120V PW9120 2000, 120V

    PW9120 2000i, 230V PW9120 3000i, 230V

  • 8/18/2019 Eaton powerware

    5/6

    POWERWARE 9120

    Electrical Input

    Nominal Voltage 120 Vac and 230 Vac;

    See Model Selection Guide

    for user-selectable voltages

    Input Voltage Range 120V: 80 –144 Vac

      230V: 120/140/160-276 Vac

    Input Power Factor >.95%

    Operating Frequency 50/60 Hz, Auto-sensing

    Frequency Range 45-65 Hz

    Input Protection Fuse or circuit breaker

    Electrical Output

    On Utility Voltage Regulation ±2% of nominal

    On Battery Voltage Regulation ±3% of nominal

    Nominal Output Voltage Same as selected input voltage

    Output Voltage Waveform Sine Wave

    Output Voltage Distortion 86%;Hi-Efficiency Mode: >90%

    Communications

    User Interface LCD status screen

    Audible Alarms UPS alarm conditions,

    including: On-Battery, Low

    Battery, Overload, UPS Fault

    Network Transient Protector In and out jack for all models.

    UL497A tested

    REPO Port Meets NEC code 645-11 intent and UL require-

    ments

    Communications One RS232 Serial Port; One

    Communications Slot; One USB Port

    Communications Cable 6-foot communications cable included

    Power Management Software Powerware Software Suite

    CD,free updates on

    www.powerware.com

    General

    Topology True online double-conversion

    Diagnostics Full system self-test on

    power up

    UPS Bypass Automatic on Overload or

    UPS failure < 4ms

    Transfer Time to Battery 0 ms

    Dimensions and Weights See Model Selection Guide

    Overload Capacity 125% for 10 minutes before transfer to bypass;

    150% for 10 seconds before transfer to bypass

    Technical Specifications1

    Battery

    Internal/EBM Battery Type Sealed, lead-acid; maintenance free

    Battery Runtime See Battery Runtime table

    Battery Replacement Hot-swappable internal and

    external batteries

    Recharge Time

  • 8/18/2019 Eaton powerware

    6/6

    AVAILABLE OPTIONS

    Order Number Description

    IPK-0329 ConnectUPS-BD SNMP/WEB Card

    1014018 AS/400 Relay Card

    MODEL SELECTION TABLE - POWERWARE 9120 UPS

    Model Power Out Input/OutPut Frequency Input Output Dimensions Weight  (VA/Watt) Voltage (Vac) (Hz)2 Connection3 Receptacles4 (H x W x D) in/mm (LB/KG)

    120 Vac Models1

    PW9120 700 700/490 120 50/60 5-15P (4) 5-15R 9.6 x6.2 x16.2/

    243 x 158 x 412 29/13.2

    PW9120 1000 1000/700 120 50/60 5-15P (4) 5-15R, 9.6 x 6.2 x 16.2/(2) 5-20R 243 x 158 x 412 35.5/16.1

    PW9120 1500 1500/1050 120 50/60 5-15P (4) 5-15R, 10.8 x 6.7 x 17.5/(2) 5-20R 275 x 170 x 444 46.5/21.1

    PW9120 2000 2000/1400 120 50/60 5-20P (6) 5-20R 14.2 x 8.6 x 18.6/

    361 x 217 x 472 82/37.2PW9120 3000 3000/2100 120 50/60 L5-30P (4) 5-15R, 14.2 x 8.6 x 18.6/

    (2) 5-20R, 361 x 271 x x 472 89/40.5  (1) L5-30R

    PW9120 3000h 3000/2100 120 50/60 Hardwired Hardwired 361 x 271 x x 472 89/40.5

    208 Vac Models

    PW9120 3000 3000/2100 208 50/60 L6-20P (2) L6-15R, 14.2 x 8.6 x 18.6/(1) L6-20R, (1) L6-30R 361 x 217 x 472 89/40.5

    230 Vac Models5

    PW9120 700i 700/490 230 50/60 IEC-C14 (4) IEC-C13 9.6 x 6.2 x 16.2/243 x 158 x 412 28/12.6

    PW9120 1000i 1000/700 230 50/60 IEC-C14 (4) IEC-C13 9.6 x 6.2 x 16.2/243 x 158 x 412 34/15.3

    PW9120 1500i 1500/1050 230 50/60 IEC-C14 (4) IEC-C13 10.8 x 6.7 x 17.5/275 x 170 x 444 44/19.8

    PW9120 2000i 2000/1400 230 50/60 IEC-C14 (4) IEC-C13, 14.2 x 8.6 x 18.6/(1) IEC-C19 361 x 217 x 472 81.6/37

    PW9120 3000i 3000/2100 230 50/60 IEC-C20 (4) IEC-C13, 14.2 x 8.6 x 18.6/(1) IEC-C19 361 x 217 x 472 85/38.5

    Optional Extended Battery Modules (EBMs)

    PW9120 BATT 700 – – – Standard – 9.6 x 6.2 x 16.2/Connector 243 x 158 x 412 31/14

    PW9120 BATT 1000 – – – Standard – 9.6 x 6.2 x 16.2/Connector 243 x 158 x 412 44/20

    PW9120 BATT 1500 – – – Standard – 10.8 x 6.7 x 17.5/Connector 275 x 170 x 444 57/26

    PW9120 BATT 2000 – – – Standard – 14.2 x 8.6 x 18.6/Connector 361 x 217 x 472 110/50

    PW9120 BATT 3000 – – – Standard – 14.2 x 8.6 x 18.6/Connector 361 x 217 x 472 110/50

    1. Also user-selectable for 100, 110 and 127 Vac. 2. Automatic frequency selection. 3. 120V models have 6-ft attached line cord. 230V models have 6-ft detachable line cord.4. Divided into 2 load segments (receptacle groups). 5. Also user-selectable for 220 and 240 Vac.

    © 2006 Eaton CorporationAll Rights ReservedPrinted in USA9120FXAApril 2006

    UNITED STATES

    8609 Six Forks Road

    Raleigh, NC 27615 U.S.A.

    Toll Free: 1.800.356.5794

    or 919.872.3020

    www.powerware.com

    CANADA

    Ontario: 416.798.0112

    LATIN AMERICA

    Argentina: 54.11.4343.6323

    Brazil: 55.11.3616.8500

    México: 52.55.5488.5252

    EUROPE/MIDDLE EAST/AFRICA

    Denmark: 45.3686.7910

    Finland: 358.94.52.661

    France: 33.1.6012.7400

    Germany: 49.7841.666.0

    Italy: 39.02.66.04.05.40

    Norway: 47.23.03.65.50

    Sweden: 46.8.598.940.00

    United Kingdom: 44.1753.608.700

    ASIA PACIFIC

    Australia/NZ: 61.2.9693.9633

    China: 86.21.6361.5599

    HK/Korea/Taiwan: 852.2745.6682

    India: 91.11.2649.9414 to 18

    Singapore/SEA: 65.6829.8888

    Powerware, Advanced Battery Managemen

    (ABM), LanSafe, OnliNet, PowerVision, and

    Foreseer are trade names, trademarks, and/

    or service marks of Eaton Corporation or itssubsidiaries and affiliates.