eaton powerware
TRANSCRIPT
-
8/18/2019 Eaton powerware
1/6
provides 60-day notification o
the end of useful life for the b
teries.
The Powerware 9120’s com-
munications are flexible,allowing for local, network or
remote monitoring and man-
agement. The Powerware 912
includes the latest version of
the Powerware Software Suit
which provides power monito
ing and shutdown software.
Simple plug-and-play operati
makes installing the Powerwa
9120 fast and easy. A single b
ton touch provides clean, uni
terruptible power to the critic
load. An intuitive LCD screen
provides real-time updates of
UPS status, power usage, bat
tery runtime remaining, and
other critical UPS parameters
With the Powerware 9120, Ea
delivers a best-in-class powe
solution for maximum system
availability, and peace of min
As businesses become increas-
ingly dependent on technology
for their fundamental operation,
the need for system availability
is of paramount importance.
The Powerware 9120 UPS isdesigned for those applications
that need maximum protection
in the 700 VA – 3 kVA range.
With its high-frequency, double-
conversion online topology, pro-
viding nonstop clean sine wave
power, advanced communica-
tions and space-saving tower
design, the Powerware 9120 is
the ideal solution for networks,
web servers, telecommunica-
tions applications and other
critical electronic equipment.
In addition to its proven design,
the Powerware 9120 offers
Advanced Battery Management
(ABM)® and sophisticated com-
munications to provide maxi-
mum system availabil ity. ABM
uses a three-stage charging
technique that not only doubles
battery service life, but opti-
mizes battery charge time and
Features • True double-conversion online technology gives you protec-
tion from all nine power problems
• Simple installation and operation
• Intuitive LCD screen provides real-time updates of UPS status,
power usage, battery runtime remaining and other critical UPS
parameters
• Hot-swappable batteries
• Extended runtime capability with external battery modules
• Complete offering of power management software included
to ensure data integrity
• User-selectable High Efficiency Mode
• Provides investment protection with a two-year limited
warranty, 10-year pro-rated warranty, $250,000 load protectionguarantee (U.S. and Canada)
Product Snapshot
Power Rating: 700-3000VA
Voltage: 120 and 230 Vac
Frequency: 50/60 Hz(auto-sensing)
Configuration: tower
Powerware® 9120Uninterruptible Power SystemProduct Focus
-
8/18/2019 Eaton powerware
2/6
Series 9 PowerProtection
True Online Design
True online systems such
as the Powerware 9120 are
the only type of UPSs that
completely isolate con-
nected equipment from all
nine of the most common
power problems:
Even when presented
with the most severe of
these power problems, the
Powerware 9120 output
remains within a remark-
able ±2% of nominal volt-
age, meaning that your
critical system always
receives clean power. In
addition, the Powerware
9120 transfers to battery
with no break in power,
making it the perfect UPS
for equipment in environ-
ments plagued by poor
power.
Power Failures
Power Sags
Power Surges
Undervoltage
Electrical
Line Noise
Overvoltage
Frequency
Variation
Switching
Transient
Harmonic
Distortion
Powerware 9120 Features
Starts up/Shuts
down the UPS
Scroll meters/
Select UPS settings
Scroll UPS settings/
Select UPS setting param-
eter
LCD
Front Panel Display
Informative user interface with LCD, four LED and audible alarms.
Loads Segments, Network Transient Protector andRemote Emergency Power Off (REPO) Port
Load Segments are groups of receptacles
that can be independently controlled and
extend battery backup times for critical
equipment.
To preserve battery power for more critical
equipment connected to Load Segment 1,
shut down Load Segment 2 supporting less
critical equipment.
Shut down and power up Load Segments in
user-defined sequence.
The Network Transient Protector isolates
your modem, fax machine, and other elec-
tronic equipment from “back door” power
surges.
The REPO port enables you to shut
down the UPS and connected equipment
from a remote location in an emergency.
1
23
4
1 UPS On
2 On Battery
3 On Bypass
Powerware
9120 1000 Shown
-
8/18/2019 Eaton powerware
3/6
Hot-Swappable Batteries
You can hot-swap batteries without powering down the critical load. This makes it possible to extend
the life of your UPS without returning the unit for service.
Extended Battery Modules (EBMs)
Increasing battery backup time is as simple as plugging in an extended battery module. Hot-swap ca
bility on all Powerware 9120 models allows you to expand runtime or replace battery modules while
keeping your critical load up and running.
Advanced Battery Management (ABM) Technology Doubles Battery Service Life
Battery Features and Runtimes
The lead-acid batteries typically used in a UPS are considered viable
as long as they can maintain backup time of at least half that of new
batteries. The illustration below to the right shows that batteries that
are constantly trickle charged (as are virtually all other UPS batteries
on the market today) reach the end of their useful life in less than
half the time of batteries charged using ABM. ABM uses a three-
stage charging technique that not only doubles battery service life,
but also optimizes battery recharge time and provides advanced noti-
fication of the end of useful battery life.Data based upon tests performed by an independent
battery manufacturer
Powerware 9120 - 1000 VA shown
with front cover removed and bat-
tery shown sliding out.
BATTERY RUNTIME CHART (IN MINUTES FULL LOAD/HALF LOAD)*
VA Standard Internal Battery 1 EBM 2 EBMs 3 EBMs 4 EBMs 5 EBMs
700 7/18 34/70 64/140 — — —
1000 7/18 36/80 66/155 — — —
1500 7/18 29/67 56/130 — — —
2000 12/34 49/107 93/195 140/310 192/403 240/504
3000 6/15 30/70 57/128 87/191 120/264 148/325
*Up to 2 EBMs can be connected to 700/1000/1500 VA models and up to 5 EBMs can be connected to 2000/3000 VA models. Runtime chart provides typical informa- tion. Runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.
-
8/18/2019 Eaton powerware
4/6
Communications
• USB port (standard) allows UPS to communicate with Windows 98 and ME computers
• RS232 Port (standard) for interface with power management software
• SNMP/Web card (optional) adds direct control and monitoring capabilities in SNMP-basednetworks. Ability to monitor UPS status and meters through Web browser interface
• Relay card (optional) adds integration to industrial environment and building management
systems, shutdown for IBM AS/400.
S O F T W A R E S U I T E
LanSafe III &
CheckUPSNetwork Shutdown
for UPSs
LanSafe III &CheckUPS
Network Shutdownfor UPSs
OnliNetSNMP-Based
Network Shutdown& Monitoring
OnliNetSNMP-Based
Network Shutdown& Monitoring
ForeseerFacility & DataCenter Management
ForeseerFacility & Data
Center Management
ForeseerFacility & Data
Center Management
LanSafe III &
CheckUPSNetwork Shutdown
for UPSs
PowerVisionUPS Performance
Analysis &Monitoring
PowerVisionUPS Performance
Analysis &Monitoring
PowerVisionUPS Performance
Analysis &Monitoring
OnliNetSNMP-Based
Network Shutdown& Monitoring
Powerware Software Suite
The industry’s most comprehensive software bundle, the Powerware Software Suite CD, is free and
included with every Powerware 9120 UPS.
• Software Wizard guides you through software selection and installation
• In addition to multimedia demonstrations, product data sheets, and video clips, the Software Suite
contains the following power management software:
– LanSafe® III and CheckUPS network shutdown for UPSs
– OnliNet® software (Lite / Vista / Centro): SNMP-based network shutdown and monitoring for UPSs
– PowerVision® software (30-day trial version): UPS performance analysis and monitoring
– Foreseer® software (demonstration): Facility and data center management
Software and Connectivity Options
SNMP/Web Card shown
PW9120 1000, 120V
Rear Panels: 120V, 208V and 230V Models
Four IEC-C13Receptacles
USB Port
CommunicationPort
Fan
NetworkTransientProtector
Communication Slot
REPO Port
BatteryConnector
IEC-C14 InputConnector
PW9120 3000, 120V PW9120 3000, 208V PW9120 700i/1000i, 230V PW9120 1500i, 230V
PW9120 700, 120V PW9120 1500, 120V PW9120 2000, 120V
PW9120 2000i, 230V PW9120 3000i, 230V
-
8/18/2019 Eaton powerware
5/6
POWERWARE 9120
Electrical Input
Nominal Voltage 120 Vac and 230 Vac;
See Model Selection Guide
for user-selectable voltages
Input Voltage Range 120V: 80 –144 Vac
230V: 120/140/160-276 Vac
Input Power Factor >.95%
Operating Frequency 50/60 Hz, Auto-sensing
Frequency Range 45-65 Hz
Input Protection Fuse or circuit breaker
Electrical Output
On Utility Voltage Regulation ±2% of nominal
On Battery Voltage Regulation ±3% of nominal
Nominal Output Voltage Same as selected input voltage
Output Voltage Waveform Sine Wave
Output Voltage Distortion 86%;Hi-Efficiency Mode: >90%
Communications
User Interface LCD status screen
Audible Alarms UPS alarm conditions,
including: On-Battery, Low
Battery, Overload, UPS Fault
Network Transient Protector In and out jack for all models.
UL497A tested
REPO Port Meets NEC code 645-11 intent and UL require-
ments
Communications One RS232 Serial Port; One
Communications Slot; One USB Port
Communications Cable 6-foot communications cable included
Power Management Software Powerware Software Suite
CD,free updates on
www.powerware.com
General
Topology True online double-conversion
Diagnostics Full system self-test on
power up
UPS Bypass Automatic on Overload or
UPS failure < 4ms
Transfer Time to Battery 0 ms
Dimensions and Weights See Model Selection Guide
Overload Capacity 125% for 10 minutes before transfer to bypass;
150% for 10 seconds before transfer to bypass
Technical Specifications1
Battery
Internal/EBM Battery Type Sealed, lead-acid; maintenance free
Battery Runtime See Battery Runtime table
Battery Replacement Hot-swappable internal and
external batteries
Recharge Time
-
8/18/2019 Eaton powerware
6/6
AVAILABLE OPTIONS
Order Number Description
IPK-0329 ConnectUPS-BD SNMP/WEB Card
1014018 AS/400 Relay Card
MODEL SELECTION TABLE - POWERWARE 9120 UPS
Model Power Out Input/OutPut Frequency Input Output Dimensions Weight (VA/Watt) Voltage (Vac) (Hz)2 Connection3 Receptacles4 (H x W x D) in/mm (LB/KG)
120 Vac Models1
PW9120 700 700/490 120 50/60 5-15P (4) 5-15R 9.6 x6.2 x16.2/
243 x 158 x 412 29/13.2
PW9120 1000 1000/700 120 50/60 5-15P (4) 5-15R, 9.6 x 6.2 x 16.2/(2) 5-20R 243 x 158 x 412 35.5/16.1
PW9120 1500 1500/1050 120 50/60 5-15P (4) 5-15R, 10.8 x 6.7 x 17.5/(2) 5-20R 275 x 170 x 444 46.5/21.1
PW9120 2000 2000/1400 120 50/60 5-20P (6) 5-20R 14.2 x 8.6 x 18.6/
361 x 217 x 472 82/37.2PW9120 3000 3000/2100 120 50/60 L5-30P (4) 5-15R, 14.2 x 8.6 x 18.6/
(2) 5-20R, 361 x 271 x x 472 89/40.5 (1) L5-30R
PW9120 3000h 3000/2100 120 50/60 Hardwired Hardwired 361 x 271 x x 472 89/40.5
208 Vac Models
PW9120 3000 3000/2100 208 50/60 L6-20P (2) L6-15R, 14.2 x 8.6 x 18.6/(1) L6-20R, (1) L6-30R 361 x 217 x 472 89/40.5
230 Vac Models5
PW9120 700i 700/490 230 50/60 IEC-C14 (4) IEC-C13 9.6 x 6.2 x 16.2/243 x 158 x 412 28/12.6
PW9120 1000i 1000/700 230 50/60 IEC-C14 (4) IEC-C13 9.6 x 6.2 x 16.2/243 x 158 x 412 34/15.3
PW9120 1500i 1500/1050 230 50/60 IEC-C14 (4) IEC-C13 10.8 x 6.7 x 17.5/275 x 170 x 444 44/19.8
PW9120 2000i 2000/1400 230 50/60 IEC-C14 (4) IEC-C13, 14.2 x 8.6 x 18.6/(1) IEC-C19 361 x 217 x 472 81.6/37
PW9120 3000i 3000/2100 230 50/60 IEC-C20 (4) IEC-C13, 14.2 x 8.6 x 18.6/(1) IEC-C19 361 x 217 x 472 85/38.5
Optional Extended Battery Modules (EBMs)
PW9120 BATT 700 – – – Standard – 9.6 x 6.2 x 16.2/Connector 243 x 158 x 412 31/14
PW9120 BATT 1000 – – – Standard – 9.6 x 6.2 x 16.2/Connector 243 x 158 x 412 44/20
PW9120 BATT 1500 – – – Standard – 10.8 x 6.7 x 17.5/Connector 275 x 170 x 444 57/26
PW9120 BATT 2000 – – – Standard – 14.2 x 8.6 x 18.6/Connector 361 x 217 x 472 110/50
PW9120 BATT 3000 – – – Standard – 14.2 x 8.6 x 18.6/Connector 361 x 217 x 472 110/50
1. Also user-selectable for 100, 110 and 127 Vac. 2. Automatic frequency selection. 3. 120V models have 6-ft attached line cord. 230V models have 6-ft detachable line cord.4. Divided into 2 load segments (receptacle groups). 5. Also user-selectable for 220 and 240 Vac.
© 2006 Eaton CorporationAll Rights ReservedPrinted in USA9120FXAApril 2006
UNITED STATES
8609 Six Forks Road
Raleigh, NC 27615 U.S.A.
Toll Free: 1.800.356.5794
or 919.872.3020
www.powerware.com
CANADA
Ontario: 416.798.0112
LATIN AMERICA
Argentina: 54.11.4343.6323
Brazil: 55.11.3616.8500
México: 52.55.5488.5252
EUROPE/MIDDLE EAST/AFRICA
Denmark: 45.3686.7910
Finland: 358.94.52.661
France: 33.1.6012.7400
Germany: 49.7841.666.0
Italy: 39.02.66.04.05.40
Norway: 47.23.03.65.50
Sweden: 46.8.598.940.00
United Kingdom: 44.1753.608.700
ASIA PACIFIC
Australia/NZ: 61.2.9693.9633
China: 86.21.6361.5599
HK/Korea/Taiwan: 852.2745.6682
India: 91.11.2649.9414 to 18
Singapore/SEA: 65.6829.8888
Powerware, Advanced Battery Managemen
(ABM), LanSafe, OnliNet, PowerVision, and
Foreseer are trade names, trademarks, and/
or service marks of Eaton Corporation or itssubsidiaries and affiliates.