Page 1: Eaton Quick Connect Air Brake Installation Guidepub/@eaton/@hyd/documents/content/... · 2 EATON Quick Connect Installation Guide E-BRQC-MR001-E July 2013 EATON Quick Connect Installation

Eaton® Quick Connect® Air Brake Installation Guide

Page 2: Eaton Quick Connect Air Brake Installation Guidepub/@eaton/@hyd/documents/content/... · 2 EATON Quick Connect Installation Guide E-BRQC-MR001-E July 2013 EATON Quick Connect Installation

2 EATON Quick Connect Installation Guide E-BRQC-MR001-E July 2013 3EATON Quick Connect Installation Guide E-BRQC-MR001-E July 2013

Assembly Procedures

Step 1: Using a tube cutter, make a square cut edge (maximum 15˚ cutting angle allowed).

Note: Dull knives, side-cutters, or other cutting tools may NOT ensure a good, clean cut. Burrs, oval tubing, and contamination can damage seals and other system components.

Tube Insertion

Gentle Tug

90˚15˚ max.

ColletTube Support

O-Ring Body

Step 5: Allow the tube ample room for a gradual bend. Note: Severe bends can collapse tubing, resulting in leaks, line blockage, or flow restriction.

Step 2: Insert tubing straight into fitting until a solid stop is felt. The tubing grip and seal (on the O-ring) is now accomplished.

Step 3: Gently tug on tubing to ensure tubing is secure.

Parts Reference

Step 4: Install threaded end of fitting hand tight and make final adjustment with wrench on hex or flats of fitting body. Note: Never use a wrench near the tubing entry or collet head of fitting.

Disassembly Procedures

Step 1: Check to be sure there is no air pressure.

Step 2: Depress collet head using fingers or Weatherhead® tube-release toolto release grip on tubing.

Step 3: With the collet depressed, pull the tubing from the fitting.

Tube Release Tool

Keep Collet Depressed

Remove Tube

Keep Collet Depressed

Remove Tube

Page 3: Eaton Quick Connect Air Brake Installation Guidepub/@eaton/@hyd/documents/content/... · 2 EATON Quick Connect Installation Guide E-BRQC-MR001-E July 2013 EATON Quick Connect Installation

Eaton 14615 Lone Oak RoadEden Prairie, MN 55344USATel: 952 937-9800Fax: 952 974-7722www.hydraulics.eaton.com

EatonHydraulics Business EuropeRoute de la Longeraie 71110 MorgesSwitzerlandTel: +41 (0) 21 881 4600Fax: +41 (0) 21 881 4601www.eaton.com/hydraulics

EatonHydraulics Business Asia PacificEaton BuildingNo. 7 Lane 280 Linhong Rd.Changing DistrictShanghai 200335ChinaTel: (+86 21) 5200 0099Fax: (+86 21) 2230 7240

© 2013 Eaton All Rights Reserved Printed in USA Document No. E-BRQC-MR001-EJuly 2013