(1) EC-TYPE EXAMINATION CERTIFICATE
(2) Equipment or protective system intended for use in potentially explosive atmospheres –Directive 94/9/EC
(3) EC-Type Examination Certificate Number: KEMA 00ATEX2083
(4) Equipment or protective system: Squirrel-cage induction motor type 5RE80…
(5) Manufacturer: Rotor B.V.
(6) Address: Mors 2, 7151 MX, Eibergen, The Netherlands
(7) This equipment or protective system and any acceptable variation thereto is specified inthe schedule to this certificate and the documents therein referred to.
(8) KEMA, notified body number 0344 in accordance with Article 9 of the Council Directive94/9/EC of 23 March 1994, certifies that this equipment or protective system has beenfound to comply with the Essential Health and Safety Requirements relating to thedesign and construction of equipment and protective systems intended for use inpotentially explosive atmospheres given in Annex II to the Directive.
The examination and test results are recorded in confidential report no. 2005200.
(9) Compliance with the Essential Health and Safety Requirements has been assured bycompliance with:
EN 50014 : 1997 + A1, A2 and prA3 EN 50019 : 1994 + prA1 and prA2
(10) If the sign ”X” is placed after the certificate number, it indicates that the equipment orprotective system is subject to special conditions for safe use specified in the scheduleto this certificate.
(11) This EC-Type Examination Certificate relates only to the design and construction of thespecified equipment or protective system. If applicable, further requirements of thisDirective apply to the manufacture and supply of this equipment or protective system.
(12) The marking of the equipment or protective system shall include the following:
II 2 G EEx e II T3…T1
Arnhem, 8 September 2000by order of the Board of Directors of N.V. KEMA
(13) SCHEDULE (14) to EC-Type Examination Certificate KEMA 00ATEX2083
Page 2/4
(15) DescriptionSquirrel-cage induction motor type 5RE80...Construction according to EC-type Examination Certificate KEMA 00ATEX2079 U.Ambient temperature range -40 °C ... +40 °C.
Electrical data
Motor type 5RE80M02K 5RE80M02 5RE80M04K
Rated output (kW) 0,75 1,1 0,55
Rated voltage (V ± 5 %) 400 400 400
Rated current (A) 1,81 2,50 1,59
Rated frequency (Hz ± 2 %) 50 50 50
Power factor 0,85 0,85 0,73
Rated speed (rpm) 2845 2855 1390
Insulation class F F F
IA/IN 6,2 6,4 4,6
tE for T3 (s) 11 10 21
tE for T2 (s) 13 12 24
tE for T1 (s) 13 12 24
Motor type 5RE80M04 5RE80M06K 5RE80M06
Rated output (kW) 0,75 0,37 0,55
Rated voltage (V ± 5 %) 400 400 400
Rated current (A) 2,05 1,14 1,75
Rated frequency (Hz ± 2 %) 50 50 50
Power factor 0,75 0,70 0,67
Rated speed (rpm) 1395 920 930
Insulation class F F F
IA/IN 4,8 3,6 4,0
tE for T3 (s) 16 55 27
tE for T2 (s) 19 60 30
tE for T1 (s) 19 60 30
Any voltage from 190 V up to and including 690 V is allowed if the electrical and thermal load areequal to those of the tested motor (a lower or the same current- and flux density).
(13) SCHEDULE (14) to EC-Type Examination Certificate KEMA 00ATEX2083
Page 3/4
Installation instructionsThe degree of protection of at least IP54 to EN 60034-5 is only achieved if certified cable entriesare used that are suitable for the application and correctly installed.Unused apertures shall be closed with suitable blanking elements.
The motor shall be provided with a three-phases inverse-delay overload protective device that notonly monitors the motor current but also disconnects the stalled motor within the above mentionedtE -times.
The motor shall only be used for continuous service, involving easy and infrequent starts which donot produce appreciable additional heating.
With built-in winding temperature sensors (DIN 44 082-M ...°C) in combination with a protectivedevice which is provided with the approval mark: PTB 3.53-PTC/A, the requirements of EN 50019,clause 4.7.4 are also fulfilled when the rotor is locked. At rated voltage and based on the cold state(20 °C) the delay time tA as stated below:
Motor type 5RE80M02K 5RE80M02 5RE80M04K
Temperature sensor (°C) 110 110 100
Delay time tA (s) 18 15 21
Motor type 5RE80M04 5RE80M06K 5RE80M06
Temperature sensor (°C) 110 100 110
Delay time tA (s) 21 42 31
Routine tests
The dielectric strength test according to Clause 17 of EN 60034-1 shall be carried out on eachmotor.
(16) ReportKEMA No. 2005200
(17) Special conditions for safe useIn case that the motor has a permanently connected cable the certificate number on the motor shallbe marked with a "X".
The electrical connection of the permanently connected cable shall be made in a certified enclosurein type of protection flameproof enclosure "d" or increased safety "e".
(13) SCHEDULE (14) to EC-Type Examination Certificate KEMA 00ATEX2083
Page 4/4
(18) Essential Health and Safety Requirements
Essential Health and Safety Requirements not covered by the standards listed at (9)
Clause Subject
1.0.5 Marking
1.0.6 b and d Instructions
These Essential Health and Safety Requirements are examined and positively judged. Theresults are laid down in the report listed at (16)
(19) Test documentation
1. EC-Type Examination CertificateCertificate of Conformity
KEMA 00ATEX2079 UKEMA No. Ex-00.E.2022