Page 1: ECCODES A Leader in Education Electricians. ECCODES A Leader in Education Today's presentation does not include voltage drops, power factor, increase

ECCODESA Leader in Education

Electricians

Page 2: ECCODES A Leader in Education Electricians. ECCODES A Leader in Education Today's presentation does not include voltage drops, power factor, increase

ECCODESA Leader in Education

Today's presentation does not include voltage drops, power factor, increase use of electricity, and is intended ONLY to be used as a study-aide and not to design or to be used to validate an installation.

Page 3: ECCODES A Leader in Education Electricians. ECCODES A Leader in Education Today's presentation does not include voltage drops, power factor, increase

ECCODESA Leader in Education

Electricians

Study-aide

Always consult with the local AHJ in your area for an interpretation.

Page 4: ECCODES A Leader in Education Electricians. ECCODES A Leader in Education Today's presentation does not include voltage drops, power factor, increase

ECCODESA Leader in Education

Study-aide

Questions

Page 5: ECCODES A Leader in Education Electricians. ECCODES A Leader in Education Today's presentation does not include voltage drops, power factor, increase

ECCODESA Leader in Education

Question:

a. 22,500 va. b. 12.500 va.

c. 6,250 va. d. 16,250 va.

A J. C. Penny (store) is to have 125- 20-ampere, 125-volt multiple general use receptacles installed , in various locations throughout its store. What is the DEMAND receptacle load for this installation?

Page 6: ECCODES A Leader in Education Electricians. ECCODES A Leader in Education Today's presentation does not include voltage drops, power factor, increase

ECCODESA Leader in Education

If you have selected the wrong answer. Don’t give-up try again

Back to the question

Page 7: ECCODES A Leader in Education Electricians. ECCODES A Leader in Education Today's presentation does not include voltage drops, power factor, increase

ECCODESA Leader in Education

You have answered the question correctly.

Next

Article 220

Receptacles installed, in other than dwellings, must be calculated at 180.va per receptacle on the same yoke as provided in 220.14(I) and permitted to apply the demand in 220.44. [See 220.14(I) and exception for four or more receptacles used for a specific equipment.]

EXAMPLE: 180va. X 125 = 22,500va. The first 10kw@100% remained @50%.

Page 8: ECCODES A Leader in Education Electricians. ECCODES A Leader in Education Today's presentation does not include voltage drops, power factor, increase

ECCODESA Leader in Education

Question:

a. 8

b. 9.6

c. 6.4

d. 10

The feeder demand load for an 8 kW load, increased by 20% is kVA.

Page 9: ECCODES A Leader in Education Electricians. ECCODES A Leader in Education Today's presentation does not include voltage drops, power factor, increase

ECCODESA Leader in Education

You have answered the question correctly.

Next

Article 220

EXAMPLE: 8,000 watt range is the demand load in column C of table 220.55

Therefore, 8,000 watts x .2 [increased 20%] = 1600watts added to 8,000 watts.

Page 10: ECCODES A Leader in Education Electricians. ECCODES A Leader in Education Today's presentation does not include voltage drops, power factor, increase

ECCODESA Leader in Education

Question:

a. # 8b # 6.c. # 4 d. # 2

What size THHN conductor is required to terminate to a 70-ampere circuit breaker or fuse?

Page 11: ECCODES A Leader in Education Electricians. ECCODES A Leader in Education Today's presentation does not include voltage drops, power factor, increase

ECCODESA Leader in Education

You have answered the question correctly.

Next

Article 110/310

In the question there is no mention of the temperature ratings of the equipment, such as at the breaker, therefore, looking at 110.14(C) we must use the 60 L column in table 310.15(B)(16).

Also there is no mention if the load is a continuous load, therefore, it would be considered as non-continuous and calculated @ 100%.