echipamente.pdf
TRANSCRIPT
MEDICAL GAS OUTLETS
l DIN 13260-2 l BS 5682:1998 l BS 8532:2011 l SS 875 24 30 l AFNOR NF S 90-116 / FD S 90-119 l AS 2896 l JIS T 7101
l UNI 9507 l ENV 737-6 l EN 15908 l AGSS EN ISO 9170-2 l AIR MOTOR ENV 737-6
2 0 1 5
premium
MEDICAL GAS OUTLETS
GAS OUTLETS OR RAnGE 3
UnI 9507 GAS OUTLETS 13
PRObES 15
nIST COnnECTORS 18
AnAESThETIC GAS SCAvEnGInG SySTEM (AGSS) AnD AIR MOTOR 20
ACCESSORIES 24
PRES BLOCK s.p.a. 3 Med ical Gas Outlets
vERTICAL InLET bASE bLOCk OR RAnGE
P/N A øB Gas
ZARMOR-O 18,7 8 OxygenZARMOR-V 18,7 8 VacuumZARMOR-A4 18,7 8 AirZARMOR-P 18,7 8 Nitrous oxideZARMOR-A8 18,7 8 Air-800ZARMOR-C 18,7 8 Carbon dioxideZARMOR-OP 18,7 8 Oxygen/Nitrous oxideZARMOR10-O 18,7 10 OxygenZARMOR10-V 18,7 10 VacuumZARMOR10-A4 18,7 10 AirZARMOR10-P 18,7 10 Nitrous oxideZARMOR10-A8 18,7 10 Air-800ZARMOR10-C 18,7 10 Carbon dioxideZARMOR10-OP 18,7 10 Oxygen/Nitrous oxide
c/w plug for test.
45° SIDE InLET bASE bLOCk OR RAnGE
P/N A øB Gas
ZARMOR-45-O 18,7 8 OxygenZARMOR-45-V 18,7 8 VacuumZARMOR-45-A4 18,7 8 AirZARMOR-45-P 18,7 8 Nitrous oxideZARMOR-45-A8 18,7 8 Air-800ZARMOR-45-C 18,7 8 Carbon dioxideZARMOR-45-OP 18,7 8 Oxygen/Nitrous oxideZARMOR10-45-O 18,7 10 OxygenZARMOR10-45-V 18,7 10 VacuumZARMOR10-45-A4 18,7 10 AirZARMOR10-45-P 18,7 10 Nitrous oxideZARMOR10-45-A8 18,7 10 Air-800ZARMOR10-45-C 18,7 10 Carbon dioxideZARMOR10-45-OP 18,7 10 Oxygen/Nitrous oxide
c/w plug for test.
A3645
ØB
9
A
36
45 ØB
GAS OUTLETS OR RAnGEThe terminal units of a medical gas pipeline system are
devices used to make connections and disconnections in order to provide specific medical gases to medical devices, pulmonary ventilators or other appliances.
An incorrect connection puts to hazard the life of patients, therefore the terminal units have been designed following different technical standards so to grant a non-interchange-
ability among different gases and prevent from any possible mistake.
The OR range socket can be fixed to the base block in only one position.
The profile of the installed socket is always in the correct position.
Base BlOck OR RanGeThis component is the part of the terminal unit connected to the medical gas pipeline distribution system (suction in case of vacu-um). The base blocks are designed complying with the standard EN ISO 9170-1 for design and manufacture requirements.All base blocks, except those for vacuum, are supplied with a maintenance valve to be fitted after the plumbing is completed.
Materials:Brass EN 12164 - CuZn39Pb3NBR/EPDMAISI
PRES BLOCK s.p.a. 4 Med ical Gas Outlets
vERTICAL InLET bASE bLOCk OR RAnGE C/w COPPER PIPE
P/N A øB Gas
ZARMOR-T-O 18,7 8 OxygenZARMOR-T-V 18,7 8 VacuumZARMOR-T-A4 18,7 8 AirZARMOR-T-P 18,7 8 Nitrous oxideZARMOR-T-A8 18,7 8 Air-800ZARMOR-T-C 18,7 8 Carbon dioxideZARMOR-T-OP 18,7 8 Oxygen/Nitrous oxideZARMOR10-T-O 18,7 10 OxygenZARMOR10-T-V 18,7 10 VacuumZARMOR10-T-A4 18,7 10 AirZARMOR10-T-P 18,7 10 Nitrous oxideZARMOR10-T-A8 18,7 10 Air-800ZARMOR10-T-C 18,7 10 Carbon dioxideZARMOR10-T-N 18,7 10 NitrogenZARMOR10-T-OP 18,7 10 Oxygen/Nitrous oxide
c/w plug for test.
45° SIDE InLET bASE bLOCk OR RAnGE C/w COPPER PIPE
P/N A øB Gas
ZARMOR-45T-O/1 18,7 8 OxygenZARMOR-45T-V/1 18,7 8 VacuumZARMOR-45T-A4/1 18,7 8 AirZARMOR-45T-P/1 18,7 8 Nitrous oxideZARMOR-45T-A8/1 18,7 8 Air-800ZARMOR-45T-C/1 18,7 8 Carbon dioxideZARMOR-45T-OP/1 18,7 8 Oxygen/Nitrous oxideZARMOR1045T-O/1 18,7 10 OxygenZARMOR1045T-V/1 18,7 10 VacuumZARMOR1045TA4/1 18,7 10 AirZARMOR1045T-P/1 18,7 10 Nitrous oxideZARMOR1045TA8/1 18,7 10 Air-800ZARMOR1045T-C/1 18,7 10 Carbon dioxideZARMOR1045TOP/1 18,7 10 Oxygen/Nitrous oxide
c/w plug for test.
bASE bLOCk OR RAnGE C/w bACk COPPER PIPE
P/N A øB Gas
ZARMORD-T-O 23,7 8 OxygenZARMORD-T-V 23,7 8 VacuumZARMORD-T-A4 23,7 8 AirZARMORD-T-P 23,7 8 Nitrous oxideZARMORD-T-A8 23,7 8 Air-800ZARMORD-T-C 23,7 8 Carbon dioxideZARMORD-T-N 23,7 8 Nitrogen
c/w plug for test.
bASE bLOCk OR RAnGE fOR fLExIbLE hOSE
P/N A øB Gas
ZARMORD-O-PG6 18,7 6 OxygenZARMORD-V-PG8 18,7 8 VacuumZARMORD-A4-PG6 18,7 6 AirZARMORD-P-PG6 18,7 6 Nitrous oxideZARMORD-A8-PG6 18,7 6 Air-800ZARMORD-C-PG6 18,7 6 Carbon dioxideZARMORD-N-PG6 18,7 6 Nitrogen
c/w plug for test.
ØB
45
150
36 A
ØB A36
45
ØB
45
150
36 A
3650
ØB
45
A
PRES BLOCK s.p.a. 5 Med ical Gas Outlets
bASE bLOCk OR RAnGE fOR fLExIbLE hOSE
P/N A øB Gas
ZARMOR-PG6-O 23,7 6 OxygenZARMOR-PG8-V 23,7 8 VacuumZARMOR-PG6-A4 23,7 6 AirZARMOR-PG6-P 23,7 6 Nitrous oxideZARMOR-PG6-A8 23,7 6 Air-800ZARMOR-PG6-C 23,7 6 Carbon dioxideZARMOR-PG6-N 23,7 6 Nitrogen
c/w plug for test.
ROTATInG bASE bLOCk OR RAnGE C/w hOSETAIL
P/N A øB Gas
ZARMORG-PG6-O 30 6 OxygenZARMORG-PG8-V 30 8 VacuumZARMORG-PG6-A4 30 6 AirZARMORG-PG6-P 30 6 Nitrous oxideZARMORG-PG6-A8 30 6 Air-800ZARMORG-PG6-C 30 6 Carbon dioxideZARMORG-PG6-N 30 6 Nitrogen
c/w plug for test.
bASE bLOCk OR RAnGE C/w nIST COnnECTOR
P/N A Gas
ZARMORD-O-MNIST 23,7 OxygenZARMORD-V-MNIST 23,7 VacuumZARMORD-A4-MNIST 23,7 AirZARMORD-P-MNIST 23,7 Nitrous oxideZARMORD-A8-MNIST 23,7 Air-800ZARMORD-C-MNIST 23,7 Carbon dioxideZARMORD-N-MNIST 23,7 Nitrogen
c/w plug for test.
36A
ØB
45
69
ØB
A
34
A
65
PRES BLOCK s.p.a. 6 Med ical Gas Outlets
DIN 13260-2
DIn ORPhEUS
P/N Gas
VGTDEP-OR-O OxygenVGTDEP-OR-V VacuumVGTDEP-OR-A4 AirVGTDEP-OR-P Nitrous oxideVGTDEP-OR-C Carbon dioxideVGTDEP-OR-N Nitrogen
Supplied with releaser sleeve that can be custom made on request.
Connecting backside and sleeve made of plastic.
DIn ORPhEUS PLUS
P/N Gas
VGTDE-OR-O OxygenVGTDE-OR-V VacuumVGTDE-OR-A4 AirVGTDE-OR-P Nitrous oxideVGTDE-OR-C Carbon dioxideVGTDE-OR-N Nitrogen
Supplied with releaser sleeve that can be custom made on request.
Connecting backside made of metal and sleeve of plastic.
DIn ORPhEUS PREMIUM
P/N Gas
VGTDEM-OR-O OxygenVGTDEM-OR-V VacuumVGTDEM-OR-A4 AirVGTDEM-OR-P Nitrous oxideVGTDEM-OR-C Carbon dioxideVGTDEM-OR-N Nitrogen
Supplied with releaser sleeve that can be custom made on request.
Connecting backside and sleeve made of metal.
Ø 5
3
43
Ø 5
3
43
Ø 5
3
43
sOckets OR RanGeThe socket is the female part of the terminal unit connected to the base block by a gas specific interface and which contains the gas-specific connecting point.These sockets have been designed in accordance with the fol-lowing standards:BS 5682:1998, DIN 13260-2, NF S 90-116, FD S 90-119, SS 875 24 30, JIS T 7101, AS 2896 and ENV 737-6 for the dimen-sions of linking point to the probe;EN ISO 9170-1 for design and manufacture requirements.
Materials:Brass EN 12164 - CuZn39Pb3 nickel platedNBR/EPDMAISIABS/POM
premium
plus
PRES BLOCK s.p.a. 7 Med ical Gas Outlets
DIn 13260-2 SOCkET OR RAnGE
P/N Gas
VGTDM-OR-O OxygenVGTDM-OR-V VacuumVGTDM-OR-A4 AirVGTDM-OR-P Nitrous oxideVGTDM-OR-C Carbon dioxideVGTDM-OR-N Nitrogen
Supplied with releaser sleeve that can be custom made on request.
DIn 13260-2 hORIzOnTAL SOCkET OR RAnGE
P/N Gas
VGTDMHO-OR-O OxygenVGTDMHO-OR-C Carbon dioxideVGTDMHO-OR-N Nitrogen
Supplied with releaser sleeve that can be custom made on request.
BS 5682:1998
bS 5682:1998 SOCkET OR RAnGE
P/N Gas
VGTBSM-OR-O OxygenVGTBSM-OR-V VacuumVGTBSM-OR-A4 AirVGTBSM-OR-P Nitrous oxideVGTBSM-OR-A8 Air-800
Supplied with releaser sleeve that can be custom made on request.
bS 5682:1998 hORIzOnTAL SOCkET OR RAnGE
P/N Gas
VGTBSMHO-OR-O OxygenVGTBSMHO-OR-V VacuumVGTBSMHO-OR-A4 AirVGTBSMHO-OR-P Nitrous oxideVGTBSMHO-OR-A8 Air-800
Supplied with releaser sleeve that can be custom made on request.
45
Ø45
45
Ø45
Ø50
44,5
Ø50
44,5
PRES BLOCK s.p.a. 8 Med ical Gas Outlets
bS 5682:1998 PLASTIC SOCkET OR RAnGE
P/N Gas
VGTBSP-OR-O OxygenVGTBSP-OR-V VacuumVGTBSP-OR-A4 AirVGTBSP-OR-P Nitrous oxideVGTBSP-OR-A8 Air-800
Supplied with releaser sleeve that can be custom made on request.
BS 8532:2011
AGSS bS 8532:2011 C/w PLASTIC bOx
P/N
VEGS-BS VEGS-BS/1 without box
AGSS bS 8532:2011 C/w nIST COnnECTOR
P/N
VEGS-BS-MNIST
NF S 90-116 and FD S 90-119
AfnOR SOCkET OR RAnGE
P/N Gas
VGTFM-OR-O OxygenVGTFM-OR-V VacuumVGTFM-OR-A4 AirVGTFM-OR-P Nitrous oxideVGTFM-OR-A8 Air-800VGTFM-OR-C Carbon dioxide
43
Ø50
Ø 12
150
42
2412
M27
x1
PRES BLOCK s.p.a. 9 Med ical Gas Outlets
bULkhEAD nUT
P/N A B Colour
PGTF/1 18,7 36,6 grey
GAS IDEnTIfICATIOn RInG
P/N A B Disting.colour Gas
ZGTF-O 38 55 white OxygenZGTF-V 38 55 yellow VacuumZGTF-A4 38 55 black-white AirZGTF-P 38 55 blue Nitrous oxideZGTF-A8 38 55 white-black Air-800ZGTF-C 38 55 grey Carbon dioxideZGTFD70-O 38 70 white OxygenZGTFD70-V 38 70 yellow VacuumZGTFD70-A4 38 70 black-white AirZGTFD70-P 38 70 blue Nitrous oxideZGTFD70-A8 38 70 white-black Air-800ZGTFD70-C 38 70 grey Carbon dioxide
SS 875 24 30
SS 875 24 30 SOCkET OR RAnGE
P/N Gas
VGTAM-OR-O OxygenVGTAM-OR-V VacuumVGTAM-OR-A4 AirVGTAM-OR-P Nitrous oxideVGTAM-OR-A8 Air-800VGTAM-OR-C Carbon dioxide
Supplied with releaser sleeve that can be custom made on request.
SS 875 24 30 hORIzOnTAL SOCkET OR RAnGE
P/N Gas
VGTAMHO-OR-O OxygenVGTAMHO-OR-V VacuumVGTAMHO-OR-A4 AirVGTAMHO-OR-P Nitrous oxideVGTAMHO-OR-A8 Air-800VGTAMHO-OR-C Carbon dioxide
Supplied with releaser sleeve that can be custom made on request.
A
M27
x1
B
3
A
B
43
Ø45
43
Ø45
PRES BLOCK s.p.a. 10 Med ical Gas Outlets
ENV 737-6
Env 737-6 SOCkET OR RAnGE
P/N Gas
VGTEM-OR-O OxygenVGTEM-OR-V VacuumVGTEM-OR-A4 AirVGTEM-OR-P Nitrous oxideVGTEM-OR-A8 Air-800VGTEM-OR-C Carbon dioxide
Supplied with releaser sleeve that can be custom made on request.
JIS T 7101
JIS T 7101 SOCkET OR RAnGE
P/N Gas
VGTJSM-OR-O OxygenVGTJSM-OR-V VacuumVGTJSM-OR-A4 AirVGTJSM-OR-P Nitrous oxide
AS 2896
AS 2896 OUTLET
P/N øB Gas
VGTAS-O 1/4’’ OxygenVGTAS-V 5/16’’ VacuumVGTAS-A4 1/4’’ AirVGTAS-P 1/4’’ Nitrous oxideVGTAS-A8 1/4’’ Air-800VGTAS-C 1/4’’ Carbon dioxideVGTAS-N 1/4’’ Nitrogen
AS 2896 OUTLET C/w nIST COnnECTOR
P/N Gas
VGTAS-O-MNIST OxygenVGTAS-V-MNIST VacuumVGTAS-A4-MNIST AirVGTAS-P-MNIST Nitrous oxideVGTAS-A8-MNIST Air-800VGTAS-C-MNIST Carbon dioxideVGTAS-N-MNIST Nitrogen
52
Ø53
Ø50
45
48
Ø50
Ø B
150
49
Ø 5
0
200
M22x1,5
PRES BLOCK s.p.a. 11 Med ical Gas Outlets
AS 2896 AnAESThETIC GAS SCAvEnGE
P/N øB
VEGS-AS 8
AS 2896 AnAESThETIC GAS SCAvEnGE C/w nIST COnnECTOR
P/N
VEGS-AS-MNIST
50
Ø B
50
M22x1,5
200
PRES BLOCK s.p.a. 12 Med ical Gas Outlets
Plastic BOxes fOR teRMinal units OR
bOx wIThOUT LID
P/N A B Profile
ZBOX-GT-OR 56,8 46,2 suitable for DIN 13260-2 and SS 875 24 30 standardsZBOX-GT-OR/01 56,8 52,5 suitable for BS 5682:1998 and JIS T 7101 standardsZBOX-GT-OR/02 58,8 55 suitable for ENV 737-6 standard and DIN ORPHEUS
Suitable to be either flush-mounted or wall-mounted.
bOx C/w LID fOR AfnOR OUTLET
P/N
ZBOXGTF c/w locking nut ZBOXGTF/1
LID fOR bhU AfnOR OUTLET
P/N
BOXGTF c/w locking nut BOXGTF-1
99A
79
19
B
65
65 67
46
15
65
65
56
PRES BLOCK s.p.a. 13 Med ical Gas Outlets
bASE bLOCk C/w COnnECTOR TO wELD
P/N Gas
ZARM60-O/PB OxygenZARM60-V/PB VacuumZARM60-A4/PB AirZARM45-P/PB Nitrous oxideZARM60-A8/PB Air-800ZARM60-C/PB Carbon dioxide
hExAGOnAL hEAD PLUG fOR bASE bLOCk
P/N A Disting.colour Gas
AGT-O/TPP M22x1,5D white OxygenAGT-V/TPP M24x1,5D yellow VacuumAGT-A4/TPP M20x1,5S black AirAGT-P/TPP M16x1,5D blue Nitrous oxideAGT-A8/TPP M18x1,5D black Air-800AGT-C/TPP M20x1,5D grey Carbon dioxide
c/w O-ring
8
32
Ø36
A
Ch 7
17 57
UnI 9507 GAS OUTLETSThe terminal units of a medical gas pipeline system are
devices used to make connections and disconnections in order to provide specific medical gases to medical devices, pulmonary ventilators or other appliances.
An incorrect connection puts to hazard the life of patients,
therefore the terminal units have been designed following different technical standards that ensure the accordance to the European directive 93/42/EEC so to grant a non-inter-changeability among different gases and prevent from any possible mistake.
Base BlOcksThis component is the part of the terminal unit connected to the medical gas pipeline distribution system (suction in case of vacu-um). The base blocks are designed in accordance with the stan-dard EN ISO 9170-1 for design and manufacture requirements.All base blocks, except those for vacuum, are supplied with a maintenance valve to be fitted after the plumbing is completed.
Materials:Brass EN 12164 - CuZn39Pb3NBR/EPDMAISI
PRES BLOCK s.p.a. 14 Med ical Gas Outlets
UNI 9507
UnI 9507 SOCkET
P/N A Disting.colour Gas
VGTX60-O M22x1,5D white OxygenVGT60-V M24x1,5D yellow VacuumVGT60-A4 M20x1,5S black-white AirVGT45-P M16x1,5D blue Nitrous oxideVGT60-A7 M18x1,5D white-black Air-800VGT60-C M20x1,5D grey Carbon dioxide
The sleeve can be custom made on request.
Plastic BOxes
bOx wIThOUT LID SUITAbLE fOR UnI 9507 OUTLETS
P/N
BOX-GT
Suitable to be either flush-mounted or surface-mounted
Supplied with:
- service cap;
- components designed to link the boxes to form a series.
45
A
95,5
7
Ø53
20
36,5
69
85
85107
sOckets
The socket is the female part of the terminal unit connected to the base block by a gas specific interface and which contains the gas-specific connecting point.These sockets have been designed in accordance with the fol-lowing standards:UNI 9507;EN ISO 9170-1 for design and manufacture requirements.
Materials:Brass EN 12164 - CuZn39Pb3 nickel platedNBR/EPDMAISIABS/POM
PRES BLOCK s.p.a. 15 Med ical Gas Outlets
UNI 9507
ELbOw bARb EnD PRObE
P/N Disting.colour H Gas
IGTG60-PG6-O white 6 OxygenIGTG60-PG8-V yellow 8 VacuumIGTG60-PG6-A4 black-white 6 AirIGTG45-PG6-P blue 6 Nitrous oxideIGTG60-PG6-A7 white-black 6 Air-800IGTG60-PG6-C grey 6 Carbon dioxide
Supplied with sticky label that can be custom made on request.
NF S 90-116 and FD S 90-119
STRAIGhT bARb EnD PRObE
P/N Disting.colour H Gas
IGTF-PG6-O white 6 OxygenIGTF-PG8-V yellow 8 Vacuum IGTF-PG6-A4 black-white 6 AirIGTF-PG6-P blue 6 Nitrous oxideIGTF-PG6-A8 white-black 6 Air-800IGTF-PG6-C grey 6 Carbon dioxide
Supplied with sleeve that can be custom made on request.
ELbOw bARb EnD PRObE
P/N Disting.colour H Gas
IGTGF-PG6-O white 6 OxygenIGTGF-PG8-V yellow 8 VacuumIGTGF-PG6-A4 black-white 6 AirIGTGF-PG6-P blue 6 Nitrous oxideIGTGF-PG6-A8 white-black 6 Air-800IGTGF-PG6-C grey 6 Carbon dioxide
Supplied with the sleeve that can be custom made on request.
55
6235
H
H
51
H
48
PRObESAll these male connectors to be coupled to the sockets are
non-interchangeable and are designed in accordance with the following standards:
UNI 9507, NF S 90-116, FD S 90-119, DIN 13260-2, BS 5682:1998, SS 875 24 30 and ENV 737-6 for the dimen-sions of linking point to the socket;
EN ISO 9170-1 for design and manufacture require-ments.
Materials:Brass EN 12164 - CuZn39Pb3 nickel platedAISINBR/EPDMPE/POM/ABS
PRES BLOCK s.p.a. 16 Med ical Gas Outlets
STRAIGhT SwIvEL MALE ThREADED PRObE
P/N B Disting.colour Gas
IGTF-OR-M12-O M12x1 white OxygenIGTF-OR-M12-V M12x1 yellow VacuumIGTF-OR-M12-A4 M12x1 white-black AirIGTF-OR-M12-P M12x1 blue Nitrous oxideIGTF-OR-M12-C M12x1 grey Carbon dioxideIGTF-OR-M1/8-O 1/8’’ white OxygenIGTF-OR-M1/8-V 1/8’’ yellow VacuumIGTF-OR-M1/8-A4 1/8’’ white-black AirIGTF-OR-M1/4-O 1/4’’ white OxygenIGTF-OR-M1/4-V 1/4’’ yellow Vacuum
Supplied with the sleeve that can be custom made on request.
DIN 13260-2
ELbOw bARb EnD PRObE
P/N Disting.colour H Gas
IGTGD-PG6-O white 6 OxygenIGTGD-PG8-V yellow 8 VacuumIGTGD-PG6-A4 black-white 6 AirIGTGD-PG6-P blue 6 Nitrous oxideIGTGD-PG6-C grey 6 Carbon dioxideIGTGD-PG6-N black 6 Nitrogen
Supplied with sticky label that can be custom made on request.
ELbOw bARb EnD PRObE wITh ChECk vALvE
P/N Disting.colour H Gas
IIGTGD-PG6-O white 6 OxygenIIGTGD-PG6-A4 black-white 6 AirIIGTGD-PG6-P blue 6 Nitrous oxideIIGTGD-PG6-C grey 6 Carbon dioxide
Supplied with sticky label that can be custom made on request.
ENV 737-6
ELbOw bARb EnD PRObE
P/N Disting.colour H Gas
IGTGE-PG6-O white 6 OxygenIGTGE-PG8-V yellow 8 VacuumIGTGE-PG6-A4 black-white 6 AirIGTGE-PG6-P blue 6 Nitrous oxideIGTGE-PG6-A8 white-black 6 Air-800IGTGE-PG6-C grey 6 Carbon dioxide
Supplied with sticky label that can be custom made on request.
B
Ch 20
46
41,555
H
22
28
64
55
H
22
28
64
H
55
4160
PRES BLOCK s.p.a. 17 Med ical Gas Outlets
BS 5682:1998
STRAIGhT bARb EnD PRObE
P/N H Gas
IGTBS-PG6-O 6,5 OxygenIGTBS-PG8-V 8 VacuumIGTBS-PG6-A4 6,5 AirIGTBS-PG6-P 6,5 Nitrous oxideIGTBS-PG6-A8 6,5 Air-800
Made of nickel plated brass.
SS 875 24 30
STRAIGhT bARb EnD PRObE
P/N H Gas
IGTA-PG6-O 6 OxygenIGTA-PG10-V 10 VacuumIGTA-PG8-A4 8 AirIGTA-PG6-P 6 Nitrous oxideIGTA-PG8-A8 8 Air-800IGTA-PG6-C 6 Carbon dioxide
66
H
PRES BLOCK s.p.a. 18 Med ical Gas Outlets
1ST fIx nIST COnnECTOR C/w COPPER PIPE wELDED
P/N A Gas
VGTN-PL-O-T1/2 1/2’’ OxygenVGTN-PL-A4-T1/2 1/2’’ AirVGTN-PL-V-T1/2 1/2’’ VacuumVGTN-PL-P-T1/2 1/2’’ Nitrous oxideVGTN-PL-C-T1/2 1/2’’ Carbon dioxideVGTN-PL-A8-T1/2 1/2’’ Air-800
PL = free flow
1ST fIx nIST COnnECTOR C/w ChECk vALvE AnD COPPER PIPE wELDED
P/N A Gas
VGTN-O-T10 10 OxygenVGTN-A4-T10 10 AirVGTN-V-T12 12 VacuumVGTN-P-T10 10 Nitrous oxideVGTN-C-T10 10 Carbon dioxideVGTN-A8-T10 10 Air-800VGTN-AGSS-T15* 15 AGSS
*No check valve
1ST fIx nIST COnnECTOR C/w hOSETAIL & ChECk vALvE
P/N A Gas
VGTN-O-PG6 6 OxygenVGTN-A4-PG6 6 AirVGTN-V-PG8 8 VacuumVGTN-P-PG6 6 Nitrous oxideVGTN-C-PG6 6 Carbon dioxideVGTN-A8-PG6 6 Air-800
1ST fIx nIST COnnECTOR C/w hOSETAIL
P/N A Gas
VGTN-PL-O-PG6 6 OxygenVGTN-PL-A4-PG6 6 AirVGTN-PL-V-PG8 8 VacuumVGTN-PL-P-PG6 6 Nitrous oxideVGTN-PL-A8-PG6 6 Air-800VGTN-PL-C-PG6 6 Carbon dioxide
PL= free flow
M22
x1,5
120
161,5
A
Ch 29
M22
x1,5
200
150
Ch 32
A
Ch22
205
M22
x1,
A
21
70
59
M22
x1,5
21
Ch17
A
nIST COnnECTORSRange of male and female components intended to main-
tain gas-specificity by allocation of a set of different diameters and screw thread to mating components to each gas. These connectors are suitable for medical gases when the pressure range is 300 kPa - 1400 kPa and for vacuum when the pres-sure range is 10 kPa - 100 kPa.
These components are designed in accordance with the standard EN 15908
Materials:Brass EN 12164 - CuZn39Pb3 nickel platedNBR/EPDMAISI
PRES BLOCK s.p.a. 19 Med ical Gas Outlets
nIST STRAIGhT bARb EnD PRObE
P/N A Gas
IGTN-PG6-O 6 OxygenIGTN-PG8-V 8 VacuumIGTN-PG6-A4 6 AirIGTN-PG6-P 6 Nitrous oxideIGTN-PG6-A8 6 Air-800IGTN-PG6-OA 6 Air/Oxygen
1ST fIx nIST COnnECTOR C/w M1/4’’ ThREAD
P/N A Gas
VGTN-O-M1/4 1/4’’ OxygenVGTN-V-M1/4* 1/4’’ VacuumVGTN-A4-1/4 1/4’’ Air
* Free flow
A
M22
x1,5
25
60,5M
22x1
,5
A
11
60
Ch 23
PRES BLOCK s.p.a. 20 Med ical Gas Outlets
AGSS TyPE 1L OUTLET fOR CEnTRALIzED SySTEM
P/N Disting.colour
VEGS120/EN1 magenta
Supplied with metal sleeve that can be custom made on request.
AGSS TyPE 1L ACTIvE
P/N Disting.colour øA øB
VEGA120/EN1 magenta 10 (supply) 16 (evacuation)
Supplied with:
- adjusting screw for setting following the standard EN ISO 7396-2
.- green suction indicator.
- sleeve that can be custom made on request.
- manifold for connecting the exhaust copper pipe.
Ø50
Ø12
47,531,5
Ø65
Ø50
ØB
ØA
AnAESThETIC GAS SCAvEnGInG SySTEM (AGSS) AnD AIR MOTOR
They are the part of system to which the operator makes connection and disconnection for exhausting the medical gases coming from anaesthetic and breathing systems.
To grant the gas-specifity and prevent any mistake, these
terminal units have been designed in accordance to the euro-pean standard EN ISO 9170-2 that ensure the conformity to the european directive 93/42/EEC, taken as reference.
en isO 9170-2 aGss sOcketsThese are the female parts of a terminal unit attached to the base block by a gas-specific interface which contain the gas-specific connection point.
Materials:Brass EN 12164 - CuZn39Pb3Aluminium series 2000 or 6000SteelNBRAISIPA/POM
PRES BLOCK s.p.a. 21 Med ical Gas Outlets
AGSS TyPE 1L ACTIvE C/w bULkhEAD PLATE
P/N Disting.colour øA øB
VEGA120/EN2 magenta 10 (supply) 16 (evacuation)
Supplied with:
- adjusting screw for setting following the standard EN ISO 7396-2.
- green suction indicator.
- sleeve that can be custom made on request.
- manifold for connecting the exhaust copper pipe.
AGSS TyPE 1L ACTIvE fOR CEILInG PEnDAnTS
P/N Disting.colour øA
VEGA120/EN3 magenta 10 (supply )
Supplied with:
- adjusting screw for setting following the standard EN ISO 7396-2.
- green suction indicator.
- sleeve that can be custom made on request.
- adapter for connecting the exhaust copper pipe or flexible hose.
bOx fOR AGSS ACTIvE OUTLET
P/N
BOX-AGSS
Made of aluminium.
Ø65
Ø50
ØB
ØA
Ø65
Ø50
15
20ØA
60
52
120
125
252
212
Ø13
157
20
PRES BLOCK s.p.a. 22 Med ical Gas Outlets
60° bARb EnD TyPE 1L
P/N Disting.colour D øG E
IEGG120-PG22/EN magenta 30 22 63
D
Ø G
60°E
30
en isO 91790-2 aGss PROBes These are the male non-interchangeable parts to be connected to the outlets.
Materials:Aluminium series 2000 or 6000 anodized
aiR MOtOR enV 737-6This terminal unit integrates a medical tool drive outlet with a gas scavenging terminal unit.
Materials:Brass EN 12164 - CuZn39Pb3 nickel platedSteelNBRAnodized Aluminium
Env 737-6 OUTLET fOR CEILInG PEnDAnTS
P/N
VAM737-PG6
Ø9
Ø15
82
Ø70
Ø64
PRES BLOCK s.p.a. 23 Med ical Gas Outlets
Env 737-6 OUTLET C/w COPPER PIPES
P/N
VAM737-TL
Env 737-6 bARb EnD PRObE
P/N
IAM737-PG6
Ø15
Ø70
Ø64
A
6068
Ø8
55,5
163
1020
Ø6
PRES BLOCK s.p.a. 24 Med ical Gas Outlets
ACCESSORIES
adaPteRs fOR aMBulancesMaterials:Brass EN 12164 - CuZn39Pb3NBR/EPDMAISIABS/POMAluminium
ADAPTER wITh OnE AfnOR nf S 90-116 SOCkET AnD bARb EnD InLET
P/N A Gas
AGTF-1V-PG6-V 6 Vacuum
ADAPTER wITh TwO AfnOR nf S 90-116 SOCkETS AnD bARb EnD InLET
P/N A Gas
AGTF-2V-PG6-O 6 OxygenAGTF-2V-PG6-V 6 Vacuum
ADAPTER wITh ThREE AfnOR nf S 90-116 SOCkETS AnD bARb EnD InLET
P/N A Gas
AGTF-3V-PG6-O 6 Oxygen
ADAPTER wITh fOUR AfnOR nf S 90-116 SOCkETS AnD bARb EnD InLET
P/N A Gas
AGTF-4V-PG6-O 6 Oxygen
24
20
A
26
60
A 110
62 24
20
26
A 117
40 19
20
26A 156
40
20
26
18
PRES BLOCK s.p.a. 25 Med ical Gas Outlets
ADAPTER wITh OnE SS 875 24 30 SOCkET AnD bARb EnD InLET
P/N A Gas
AGTA-1V-O 6 Oxygen
ADAPTER wITh TwO SS 875 24 30 SOCkETS AnD bARb EnD InLET
P/N A Gas
AGTA-2V-O 6 Oxygen
ADAPTER wITh TwO DIn 13260-2 SOCkETS AnD bARb EnD InLET
P/N A Gas
AGTD-2V-O 6 OxygenAGTD-2V-A4 6 Air
ADAPTER wITh fOUR DIn 13260-2 SOCkETS AnD bARb EnD InLET
P/N A Gas
AGTD-4V-O 6 OxygenAGTD-4V-A4 6 Air
A
54
42
21
A
54
110
68 21
64,5
110
A
6820,5
A
64,5
68 20,5
190
PRES BLOCK s.p.a. 26 Med ical Gas Outlets
Quick cOuPleRs fOR flOwMeteR and ReGulatOR
DIn MInI SOCkET MALE ThREADED
P/N øA Gas
VGTD-O-M1/4 1/4’’ OxygenVGTD-A4-M1/4 1/4’’ AirVGTD-V-M1/4 1/4’’ VacuumVGTD-P-M1/4 1/4’’ Nitrous oxideVGTD-C-M1/4 1/4’’ Carbon dioxideVGTD-O-M3/8 3/8’’ Oxygen
DIn MInI SOCkET wITh bARb EnD
P/N A Gas
VGTD-O-PG6 6 OxygenVGTD-A4-PG6 6 Air
SS MInI SOCkET MALE ThREADED
P/N A Gas
VGTA-O-M10X1 M10x1 OxygenVGTA-A4-M10X1 M10x1 AirVGTA-P-M10X1 M10x1 Nitrous oxideVGTA-C-M10X1 M10x1 Carbon dioxideVGTA-O-M1/4 1/4’’ OxygenVGTA-A4-M1/4 1/4’’ Air
AfnOR MInI SOCkET MALE ThREADED
P/N B øA Gas
VGTF-O-M1/4 6,5 1/4’’ OxygenVGTF-A4-M1/4 6,5 1/4’’ AirVGTF-O-M3/8 10 3/8’’ OxygenVGTF-A4-M3/8 10 3/8’’ AirVGTF-V-M3/8 10 3/8’’ Vacuum
bS MInI SOCkET MALE ThREADED
P/N A L Gas
VGTBS-O-M1/4/V 1/4’’ 60 Oxygen
2610
41,5
ØA
Ch27
A
50,5
Ch 27
A
41
Ch 24
ØA
39
Ch23
25
B
A
L
PRES BLOCK s.p.a. 27 Med ical Gas Outlets
JIS MInI SOCkET MALE ThREADED
P/N A L Gas
VGTJS-O-M1/4 1/4’’ 54,5 Oxygen
AS MInI SOCkET MALE ThREADED
P/N A L Gas
VGTAS-O-M1/4 1/4’’ 47 Oxygen
UnI MInI SOCkET MALE ThREADED
P/N A L Gas
VGTI60-O-M1/4 1/4’’ 56 Oxygen VGTI60-O-M3/8 3/8’’ 41 Oxygen
flexiBle hOses fOR Medical Gas
fLExIbLE hOSE fOR En ISO 5359 ASSEMbLIES
P/N Disting.colour Gas
NTPB6x12-O white OxygenNTPB8x14-V yellow VacuumNTPB6x12-A4 white-black AirNTPB6x12-P blue Nitrous oxideNTPB6x12-C grey Carbon dioxideNTPB6x12-NC black -
50 meters coil.
Without DEHP.
A
L
A
L
A
L
plus PB
CTG
TGB
PRES BLOCK S.p.A. - Via Alpignano, 151-155
I - 10040 CASELETTE (TO) Tel. +39 011 9688055 (r.a.) - Fax +39 011 9688668
http://www.presblock.com e-mail: [email protected] [email protected]
The products described herein, including without limitation, product features, specifications, designs are subject to change by Pres Block at any time without notice.