eclipse module 395w-410w behind the eclipse

2
[email protected] www.seraphim-energy.com BEHIND THE ECLIPSE We challenged ourselves to push the boundaries of PV technology and pioneer new innovations in solar module design. The design of the Eclipse module takes into consideration every element that defines a perfect solar module. The culmination of our efforts is a module that is superior in performance, reliability, safety, and value. Eclipse Module 395W-410W

Upload: others

Post on 06-Jun-2022

18 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Eclipse Module 395W-410W BEHIND THE ECLIPSE

[email protected] www.seraphim-energy.com

BEHIND THE ECLIPSEWe challenged ourselves to push the boundaries of PV technology and pioneer new innovations in solar module design. The design of the Eclipse module takes into consideration every element that defines a perfect solar module. The culmination of our efforts is a module that is superior in performance, reliability, safety, and value.

Eclipse Module

395W-410W

Page 2: Eclipse Module 395W-410W BEHIND THE ECLIPSE

Eclipse SRP-E01A(-HV)Eclipse SRP-E01A(-HV)

SRP-DS-EN-2019V2.0 | © Copyright 2019 Seraphim

Mechanical Specifications

Temperature Characteristics

Packing Configuration

Pieces per Pallet

Pallets per Container

Pieces per Container

Container

22

594

External Dimensions

Weight

Solar Cells

Front Glass

Frame

Junction Box

Output Cables

Connector

Mechanical Load

1941 x 1048 x 40 mm

23.0 kg

PERC Mono crystalline

3.2 mm AR coating tempered glass, low iron

Anodized aluminium alloy

IP68

4.0 mm ,cable length: 1000 mm

MC4 Compatible

5400 Pa

-0.37 %/°C

-0.28 %/°C

+0.05 %/°C

-40~+85 °C

45±2 °C

I-V Curve

27

2

1048±1

1941

±1

Grounding holes2×Ø4

A A

10±1

1941

±116

61±1

1161

±1

1048±1

40±1

posi

tive

( + )

nega

tive

( - )

Con

nect

or

1000±1

I

II

SE

RIA

L N

UM

BE

R

SE

RIA

L N

UM

BE

R

998±1

SER

IAL

NU

MBE

R

Mounting holes

SER

IAL

NU

MBE

R

Junction Box

Label

I

9

14

R4.5

5:1

70 70

7070

II2:1

Section A-A10:1

40

35

The Eclipse module takes advantage of Seraphim’s innovative module technology, using traditional solar cells to increase efficiency and reliability while reducing BOS cost. The Eclipse module bridges the gap between functionality and design, providing an elegant solution to all your solar energy needs.

Significantly Reduced Hot-Spot Effect

10% Reduction in BOS and Installation Cost

Installation

+System BOS

15% Greater Return on Projects

Reliable Connection

Low Resistance

Warranty

linear power output warranty

Guarantee on productmaterial and workmanship10

YEARS25YEARS

+15%

More Benefits

Certifications

Insurances

Temperature after shading test (at 5hrs, in °C)Maximum Temp

Average Temp

Minimum Temp

47.3°C

23.9°C

15.6°C

Improved Reliability and Durability

Better performance under shade

Beautifully designed

5400Pa Mechanical Load

Gua

rant

eed

Pow

er

Addtional Value from Linear Warranty

100%97% 97%

94.28%

90.88%

87.48%

84.08%

80.68%

90%

80%

0 5 10 15 20 25year

1941 x 1048 x 40 mm

Electrical Characteristics

Maximum Power (Pmp)

Open Circuit Voltage (Voc)

Short Circuit Current (Isc)

Maximum Power Voltage (Vmp)

Maximum Power Current (Imp)

Module Efficiency at STC(ηm)

Power Tolerance

Maximum System Voltage

Maximum Series Fuse Rating

STC

400

45.10

11.34

37.20

10.76

NOCT

296

41.70

9.17

34.30

8.63

STC

405

45.30

11.42

37.40

10.83

NOCT

300

41.90

9.23

34.50

8.70

STC

395

44.90

11.25

37.00

10.68

NOCT

293

41.60

9.12

34.20

8.57

19.42 19.66 19.91

SRP-395-E01ASRP-395-E01A-HV

STC

410

45.50

11.51

37.60

10.91

NOCT

304

42.10

9.29

34.70

8.77

20.16

SRP-410-E01ASRP-410-E01A-HV

SRP-400-E01ASRP-400-E01A-HV

SRP-405-E01ASRP-405-E01A-HV

(0,+4.99)

1000 VDC / 1500 VDC

20A

0 10 20 30 40 50Voltage [V]

0

2

4

6

8

10

12

14

Cur

rent

[A]

Incident Irrad. = 1000 W/m²

Cells temp. = 25 °C

Incident Irrad. = 800 W/m²

Incident Irrad. = 600 W/m²

Incident Irrad. = 400 W/m²

Incident Irrad. = 200 W/m²

0 10 20 30 40 50Voltage [V]

0

2

4

6

8

10

12

Cur

rent

[A]

Incident Irrad. = 1000 W/m²Cells temp. = 10 °CCells temp. = 25 °CCells temp. = 40 °CCells temp. = 55 °CCells temp. = 70 °C

40’HQ

STC: lrradiance 1000 W/m2 module temperature 25°C AM=1.5,Power measurement tolerance: +/-3%;NOCT: lrradiance 800 W/m2 ambient temperature 20°C wind speed :1m/s Power measurement tolerance: +/-3%

SRP-XXX-E01A-HV: Maximum System Voltage1500 VDCSRP-XXX-E01A: Maximum System Voltage1000 VDC