Page 1: Ecloud  in the Main Injector

Ecloud in the Main Injector

Author: Michael BackfishJuly 15, 2010 Ecloud Meeting

All data is taken between 9/11/2009 and Now

Page 2: Ecloud  in the Main Injector

Ecloud Detector Signals With Main Injector Beam Intensity and Ramp

Page 3: Ecloud  in the Main Injector

By datalogging our signals at a time that will give us a sample of the maximum signal achieved, and then plotting the data vs beam intensity we can see how the signal changes with an increase in beam intensity.

Page 4: Ecloud  in the Main Injector

Basic Method• Data Log detector signals on an event at the time when the signal is maximum• Export 1 file from D44 for each day • Use Excel to Remove any duplicate values because Mathematica does not like to fit a function if there is more than 1 Y value for every X value• Save it as a text file which will then be accessed with Mathematica• Use Mathematica to filter out unwanted data (overdriven signals or timing jitter which will be shown later)• Fit a curve that we will be able to track through time

Page 5: Ecloud  in the Main Injector

Data Exported From D44Filter for any duplicate I:BEAM values in excel and save as a txt file

Page 6: Ecloud  in the Main Injector

Timing JitterWe initially data logged on the $8D in order to only see Pbar/Numi pulses.

For some unknown reason a jitter occurs when using this event.In early March we found that Data logging on the $8E alleviated this jitter

$8D $8E

Page 7: Ecloud  in the Main Injector

Timing JitterWe initially data logged on the $8D in order to only see Pbar/Numi pulses.

For some unknown reason a jitter occurs when using this event.In early March we found that Data logging on the $8E alleviated this jitter

I:BEAM

I:CLO

UD1

Page 8: Ecloud  in the Main Injector

Different Bunch StructureShows different charactersitics than timing jitter

Page 9: Ecloud  in the Main Injector

Signal=z-e^(a*(x-X0))x is the beam intensity

When x=X0 the signal equals z-1Thus by tracking X0 we can track the conditioning of the beam pipe

over time

Page 10: Ecloud  in the Main Injector

8/25/2009 10/14/2009 12/3/2009 1/22/2010 3/13/2010 5/2/2010 6/21/20100

10

20

30

40

50

60

X0 RFA1

X0 RFA3X0

Page 11: Ecloud  in the Main Injector

8/25/2009 10/14/2009 12/3/2009 1/22/2010 3/13/2010 5/2/2010 6/21/20100

10

20

30

40

50

60

Plotting X0 with Extrapolated Data

X0 RFA1X0 RFA3

X0

Page 12: Ecloud  in the Main Injector

I:BEAM is datalogged on the $AD for every Numi pulse since the beginning of the last shutdown

Since we now have an equation Signal=z-e^(a*(x-X0))

We can use I:BEAM data from each pulse to know the maximum value that our signal

reached

Page 13: Ecloud  in the Main Injector

Knowing the maximum detector signal for each I:BEAM pulse allows to extrapolate a curve for each pulse. A Lorentzian fit works for a rough estimate.

Signal=a/[(x-x0)^2+λ]

RFA1 RFA3

Page 14: Ecloud  in the Main Injector

8/25/2009 10/14/2009 12/3/2009 1/22/2010 3/13/2010 5/2/2010 6/21/2010

-7.00E+06

-6.00E+06

-5.00E+06

-4.00E+06

-3.00E+06

-2.00E+06

-1.00E+06

0.00E+00

Daily Running Sum of Integrated Charge

RFA1 No LiningRFA 3 Lined with Titanium Nitride

Sept 12 to May 1

Char

ge

Page 15: Ecloud  in the Main Injector

Every day we find the integral of the lorentzian for each Numi beam pulse and sum them all. We the do a net sum for each consecutive day. Thus it is the sum of the integral of our extrapolated lorentzian function for every beam pulse.

Note the different scales on the two plots below.

Page 16: Ecloud  in the Main Injector

Still need to convert this to total charge

• There is a 40 dB gain in the preamp thus V1*100=V2 where V2 is what we see upstairs.• Based on the preamp design the electrons see a 1 MW

resistance thus: (V2/100)/1 MW = I• Using Lee’s data we also know that between 18 and 22 Volts

on the grid our detector has about a 62% efficiency.• Lastly we will compensate for lost signal due to the escape

slits in the beam pipe.

Using this we can convert our Integral of a Voltage signal to a true charge sum and correct the units on the plots………..I just have not done it yet.

Page 17: Ecloud  in the Main Injector
Page 18: Ecloud  in the Main Injector

Signals from September

Page 19: Ecloud  in the Main Injector

March 24

Page 20: Ecloud  in the Main Injector

June 9

Page 21: Ecloud  in the Main Injector

Zooming in on RFA3 We no longer see the gaussian like shape, but we do still get a small signal that

increases through the entire cycle

Page 22: Ecloud  in the Main Injector

An interesting little experiment3 Bump at HP520 and VP521 slot 5

Page 23: Ecloud  in the Main Injector

Note I:CLOUD1 and I:CLOUD4 are facing each other with one the top and the other on the bottom

Page 24: Ecloud  in the Main Injector

Things to think about:

• Still working on calibrating hall probes to measure the MI bus magnetic field.

• If we install the Carbon coated beam pipe what better ways do we have to take data?