eddie padilla - berkeley, california · notify architect/engineer of any discrepancies found. no...
TRANSCRIPT
D0
D0
AI
DI
P
MS
FS
T
PP
TH THERMOMETER
TEMPERATURE GAUGE
TEMPERATURE SENSOR
PRESSURE SENSOR/TRANSMITTER
PNEUMATIC CONTROL
ELECTRICAL CONTROL WIRING
FLOW SWITCH/SENSOR
ANALOG OUTPUT
DIGITAL INPUT
ANALOG INPUT
DIGITAL OUTPUT
T
MAGNETIC STARTER
THERMOSTAT
PRESSURE REDUCING VALVE
TEMPERATURE CONTROL VALVE
AIR VENT VALVE-AUTOMATIC
AIR VENT VALVE-MANUAL
STRAINER
PGA
U
AVM
AVA
PRESSURE GAUGE
PETE'S PLUG
UNION CONNECTION
CKV
GLV
GV
PRV
TCV
BV
GLOBE VALVE
CHECK VALVE
GATE VALVE
BUTTERFLY VALVE
UNLESS NOTED OTHERWISE
WEATHER OR WATER PROOF
TYPICAL
VENT THRU ROOF
WEIGHT
WATER PRESSURE DROP
WT
WP
WPD
VTR
TYP
UNO
STANDARD
STEEL
STAINLESS STEEL
THERMOMETER
TOTAL STATIC PRESSURE
STL
TSP
TH
STD
SS
POUND PER SQUARE INCH GAUGE
RETURN FANRF
ROUGH IN ONLY
SUPPLY FAN
SALVAGE TO BE RE-INSTALLED
REVOLUTION PER MINUTE
RELOCATE
(S)
SF
RPM
RIO
(R)
PLUMBING
POINT OF CONNECTION
POUND PER SQUARE INCH
RELOCATED
PSI
(R)
PSIG
POC
PLBG
SD
CD
G
FS
W
X X X X
SD STORM DRAIN
3-WAY CONTROL VALVE
2-WAY CONTROL VALVE
BC
CD
BALL VALVE
BALANCING VALVE
BALANCING COCK
CONDENSATE DRAIN
G
V
HWR
CW
HW
FS
HOT WATER RETURN
GAS
VENT
COLD WATER
FIRE SPRINKLER
HOT WATER
FLEXIBLE CONNECTION
FIRE SPRINKLER HEAD
ACCESS PANEL/ACCESS DOOR
VENT RISE - VENT THRU ROOF
SANITARY OR WASTE
(E) PIPE TO BE REMOVED
(E) PIPE TO BE REMAIN
AP/AD
VR-VTR
W
DN
UP
DIRECTION OF FLOW
ALL SERVICES
ALL SERVICES
X
(E)
(N)
FP
EXISTING
NEW
SYMBOLS
1
1
M-1
ACU
1
NORTH ARROW (REFERENCE)
POINT OF DEMOLITION
EQUIPMENT IDENTIFICATION
POINT OF CONNECTION
KEYED NOTE
DETAIL OR SECTION
SHEET NUMBER
ABB'R SERVICE
NATIONAL FIRE PROTECTION ASSOCIATION
NEW
NORMALLY CLOSED
PRESSURE GAUGE
NORMALLY OPEN
NFPA
PG
NO
NC
(N)
FEET PER MINUTE
FIRE SMOKE DETECTOR
HEATER
HOT WATER
MANUFACTURER
HW
MFR
HTR
FSD
FPM
EXTERNAL STATIC PRESSURE
EXISTING
EXHAUST FAN
FLEXIBLE CONNECTION
FIRE SPRINKLER
ESP
FC
F
EF
(E)
CEILING
CUBIC FEET PER MINUTE
DOWN
CONNECT TO EXISTING
DISPOSE
DN
(D)
CTE
CLG
CFM
BRAKE HORSEPOWER/BOILER HORSEPOWER
AIR HANDLING UNITAHU
ACCESS PANEL
CAP FOR FUTURE
BOTTOM OF PIPE
CUBIC FEET PER HOUR
CFF
CFH
BOP
BHP
AP
ABOVE FINISH FLOOR
AIR CONDITIONING UNIT
AFF
ACU
REFER TO SMACNA SEISMIC GUIDELINES AND STANDARDS FOR DUCT PIPE SUPPORT AND
EQUIPMENT SEISMIC BRACING.
PROTECT THE PUBLIC FROM INJURY DURING PROGRESS OF WORK BY POSTING WARNING
SIGNS, GUARD LIGHTS AND BARRICADES.
ALL WORK SHALL BE IN COMPLIANCE WITH THE LATEST APPLICABLE LOCAL AND
STATE CODES AND REGULATIONS:
CALIFORNIA BUILDING CODE 2016
CALIFORNIA MECHANICAL CODE 2016
CALIFORNIA PLUMBING CODE 2016
CALIFORNIA FIRE CODE 2016
CALIFORNIA ELECTRICAL CODE 2016
ALL PIPING SHOWN ON PLANS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED TO
DETERMINE EXACT LOCATION. CERTAIN VERTICAL AND HORIZONTAL DIMENSIONS ARE
SHOWN IN DUCTS AND PIPES TO INDICATE THEIR GENERAL POSITION IN RELATIONSHIP TO
THE SYSTEMS WITHIN THE SPACE AVAILABLE FOR SYSTEM INSTALLATION. PROVIDE
ADDITIONAL PIPING OFFSETS AS REQUIRED, AND TO COORDINATE WITH INSTALLATION
REQUIREMENTS OF OTHER SYSTEMS AT NO ADDITIONAL COST TO THE OWNER. ALL
DIMENSIONS ARE IN INCHES OR OTHERWISE NOTED.
CONTRACTOR SHALL ASSUME SOLE RESPONSIBILITY FOR SAFETY OF ALL PERSONS ON OR
ABOUT THE CONSTRUCTION SITE, IN ACCORDANCE WITH APPLICABLE LAWS AND CODES.
GUARD ALL HAZARDS IN ACCORDANCE WITH THE SAFETY PROVISIONS OF THE LATEST
MANUAL OF ACCIDENT PREVENTION PUBLISHED BY THE ASSOCIATED GENERAL
CONTRACTORS OF AMERICA AND OSHA.
SEAL AIR AND WATER TIGHT ALL PIPE PENETRATIONS THROUGH WALL. SEALANT SHALL BE
3M BRAND PRODUCTS. BRACE ALL PIPES AND EQUIPMENT TO WITHSTAND FORCES AS
REQUIRED BY THE STATE AND LOCAL CODES.
WHERE EXISTING CONSTRUCTION IS CUT, DAMAGED, OR REMODELED, PATCH WITH
MATERIALS TO MATCH IN KIND, QUALITY, AND PERFORMANCE.
COORDINATE WORK WITH THE OWNER AND ALL OTHER TRADES.
THE EXISTING MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE MAINTAINED IN
OPERATION DURING THE DEMOLITION AND INSTALLATION OF NEW WORK. WHEN A SYSTEM
SHUTDOWN IS NECESSARY, OBTAIN A WRITTEN APPROVAL FROM THE OWNER PRIOR TO
SHUTTING DOWN OF ANY MECHANICAL ELECTRICAL SYSTEMS.
THE CONTRACTOR SHALL PROVIDE DUST BARRIER PLASTIC COVERS, SCREEN AND
TENTING AT ALL TIMES TO CONTAIN DUST AND DEBRIS WITHIN THE DESIGNATED WORK
AREA. LOCATING AND INSTALLATION OF DUST PROTECTION COVERS AND TENTING TO BE
APPROVED BY THE OWNER PRIOR TO INSTALLING. CONTRACTOR SHALL CLEAN WORK AREA
AND REMOVE DEBRIS AT THE END OF EACH WORKING DAY. DISPOSAL OF DEBRIS AND
EXCESS MATERIAL SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS.
ANY ERRORS, OMISSIONS OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE
CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT
OR ENGINEER AND OWNER BEFORE PROCEEDING WITH THE WORK.
PENETRATIONS THROUGH EXISTING CONCRETE WALL, FLOOR OR ROOF SHALL BE VERIFIED
FOR STRUCTURAL REINFORCEMENTS. X-RAY ARE REQUIRED TO LOCATE REINFORCEMENT
PRIOR TO CONCRETE CORE DRILLING OR CUTTING. OBTAIN OWNER'S WRITTEN APPROVAL
PRIOR TO CORE DRILLING AND CUTTING.
CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTION OF WORK AT HIS OWN EXPENSE
FOR WORK INSTALLED IN CONFLICT WITH CONSTRUCTION DOCUMENTS.
CONTRACTOR SHALL LEAVE PREMISES AND ALL AFFECTED AREAS CLEAN AND IN ORDERLY
MANNER READY FOR MOVE-IN OR FACILITY OPERATION.
PROVIDE ADEQUATE CLEARANCE AND ACCESS TO EQUIPMENT FOR SERVICE AND
MAINTENANCE. EQUIPMENT CLEARANCES SHALL MEET THE REQUIREMENT OF THE
MANUFACTURER.
INSULATE ALL HOT AND COLD PIPING. PROVIDE SILICATE INSERTS AT SUPPORT POINTS.
PROVIDE ALUMINUM JACKETING FOR OUTDOOR INSTALLATION.
GENERAL: THIS SCOPE OF WORK IS AN OUTLINE OF WORK INVOLVE FOR THIS PROJECT AND IS
NOT INTENDED TO DESCRIBE THE COMPLETE SCOPE OF WORK. THE DETAILED REQUIREMENTS
ARE INDICATED ON EACH DRAWING AND SPECIFICATION.
1. REMOVE AND DISPOSE EXISTING PLUMBING FIXTURES AS INDICATED.
PRESSURE TEST ALL PLUMBING PER CPC 2016.6.
7. FLUSH AND DISINFECT ALL WATER PIPING AND EQUIPMENT PER CPC 2016.
P1.00 LEGEND, SYMBOLS, GENERAL NOTES, SCOPE OF WORK & DRAWING INDEX
P2.11 FIRST FLOOR PLAN - PLUMBING DEMOLITION
P1.01 SPECIFICATIONS, PLUMBING FIXTURE SCHEDULE AND DETAILS
3. PROVIDE NEW JANITOR SINK AS INDICATED. EXTEND EXISTING PLUMBING UTILITIES AS
REQUIRED.
4. PROVIDE NEW SHOWERS. EXTEND AND MODIFY EXISTING PLUMBING UTILITIES AS REQUIRED.
MODIFY EXISTING PLUMBING AS NECESSARY.
EXPLORATORY WORK TO SEARCH FOR PIPING, PLUMBING OR DUCT FOR CONNECTIONS
TO EXISTING BUILDING SYSTEM INCLUDING POINT OF CONNECTIONS UNDER FLOOR SLAB,
IN WALLS AND CEILING SHALL BE INCLUDED AT NO COST TO THE OWNER. CUTTING,
PATCHING AND RESTORATION OF FLOORS, WALLS, CEILING AND FINISH SHALL BE
INCLUDED IN THIS WORK AT NO COST TO THE OWNER. RESTORATION OF WALL OR FLOOR
FINISH SHALL MATCH EXISTING.
19.
ALL PLUMBING PIPING MATERIAL, PLUMBING FIXTURE, VALVE, FIITINGS AND ACCESSORIES
SHALL BE 'LEAD-FREE' IN ACCORDANCE WITH CALIFORNIA REGULATION AB1953. PROVIDE
SUBMITTAL FROM MANUFACTURER'S FOR COMPLIANCE.
20.
18.
17.
16.
15.
14.
13.
11.
10.
9.
8.
6.
5.
4.
3.
2.
1.
P2.21 FIRST FLOOR PLAN - PLUMBING
P2.22 SECOND FLOOR PLAN - PLUMBING
2. PROVIDE NEW PLUMBING FIXTURES AS INDICATED. EXTEND AND MODIFY EXISTING
PLUMBING UTILITIES AS NECESSARY.
P2.12 SECOND FLOOR PLAN - PLUMBING DEMOLITION
P3.01 DETAILS - PLUMBING
7.
SHOWER UNITSH0-1
VERIFY DIMENSIONS OF OWNER FURNISHED EQUIPMENT TO ENSURE PROPER
COORDINATION WITH CONSTRUCTION DOCUMENTS. NOTIFY ARCHITECT/ENGINEER OF ANY
DISCREPANCIES FOUND. NO ALLOWANCE SHALL BE MADE FOR ANY EXPENSE TO WHICH
THE CONTRACTOR MAY INCUR DUE TO FAILURE OR NEGLECT ON HIS PART TO MAKE SUCH
VERIFICATION.
12.
FP2.21 FIRST FLOOR PLAN - FIRE PROTECTION
FP2.22 SECOND FLOOR PLAN - FIRE PROTECTION
REVISIONS
SHEET NUMBER
SHEET TITLE
N&T JOB #
ISSUE DATE
729 Heinz AvenueBerkeley, CA 94710
tel 510.542.2200fax 510.542.2201
SEAL
APPROVALS
1901 HEARST ST.
BERKELEY CA 94704
21603.00
12/19/18
# DATE DESCRIPTION
EDDIEPADILLA
274 Devonshire Street
5. PROVIDE NEW HI/LO DRINKING FOUNTAIN WITH COOLER AS INDICATED. EXTEND AND MODITY
EXISTING PLUMBING UTILITIES AS NECESSARY.
DISINFECTION PROCEDURE:
A. POST SUITABLE WARNING SIGNS AT EACH OUTLET: 'WARNING - DO NOT USE - WATER SYSTEM BEING
CHLORINATED'.
B. INJECT DISINFECTANT SOLUTION INTO THE SYSTEM THROUGH THE SERVICE COCK BY MEANS OF A
PUMP, OR OTHER PRESSURE DEVICE, AT A SLOW CONTINUOUS RATE, SIMULTANEOUS WITH A
REDUCED FLOW FROM THE WATER MAIN, UNTIL THE ORTHOTOLIDIN TEST FOR RESIDUAL CHLORINE
AT EACH OUTLET SHOWS A CONCENTRATION OF AT LEAST 50PPM, BUT NOT MORE THAN 100 PPM.
C. CLOSE ALL OUTLETS AND VALVES, INCLUDING THE SERVICE VALVE AT THE MAIN AND THE INJECTION
COCK. RETAIN THE CHLORINATED WATER IN THE SYSTEM FOR 24 HOURS.
D. AFTER 24 HOUR HOLDING PERIOD, THE RESIDUAL CHLORINE CONCENTRATION SHALL BE NOT LESS
THE 50 PPM AS SHOWN BY THE ORTHOTOLIDIN TEST.
E. DRAIN AND FLUSH ENTIRE DOMESTIC WATER SYSTEM UNTIL ORTHOLIDIN TEST SHOW BACKGROUND
RESIDUAL CHLORINE CONCENTRATION AT ANY OUTLET.
F. ENVIRONMENTAL, HEALTH AND SAFETY (EH&S) WILL DETERMINE WHETHER SAMPLES OF WATER MUST
BE COLLECTED AND ANALYZED FOR THE DETERMINATION OF BACTERIOLOGICAL QUALITY.
G. STANDARDS NECESSARY FOR APPROVAL:
a. THE WATER SYSTEM SHALL BE UNIFORMLY CHLORINATED UNDER THE SUPERVISION OF
ENVIRONMENTAL, HEALTH AND SAFETY (EH&S) AS OUTLINED IN THE 'DISINFECTION
PROCEDURE'.
b. THE RESULT OF WATER SAMPLE ANALYSIS SHALL BE NEGATIVE FOR THE COLIFORM
ORGANISM.
c. IF THE TEST FOR THE BACTERIOLOGICAL QUALITY OF THE WATER IN THE SYSTEM DOES
NOT MEET THE STANDARDS, REPEAT THE DISINFECTION PROCEDURE UNTIL THE SPECIFIED
STANDARDS ARE MET.
I. FINAL APPROVAL: ENVIRONMENTAL, HEALTH AND SAFETY (EH&S) WILL GIVE WRITTEN APPROVAL TO
THE UNIVERSITY FOR ACCEPTANCE AND USE OF THE WATER SYSTEM AFTER THE ABOVE
PROCEDURES HAVE BEEN SUCCESSFULLY COMPLETED AND THE STANDARDS MET.
PLUMBING FIXTURE CARRIERS OR WALL SUPPORTS SHALL BE ADJUSTABLE J. R. SMITH OR EQUAL. REFER TO
ARCHITECTURAL DRAWINGS FOR PLUMBING FIXTURE LOCATION AND MOUNTING HEIGHT.
PLUMBING FIXTURES SPECIFICATIONS
REFER TO ARCHITECTURAL DRAWINGS FOR ALL PLUMBING FIXTURE LOCATION AND MOUNTING HEIGHT.
ROUGH - IN
ALL WATER CLOSETS SHALL USE A MAXIMUM OF 1.28 GALLONS PER FLUSH.1.
2.
VSS
WATER CLOSET
LAV-1LAVATORY
WC-1
2"
4" 2"
DESCRIPTION FIXTURE TAG
TWCW HW
WALL HUNG, ADA ACCESSIBLE
WHERE INDICATED.
WALL MOUNTED, ADA ACCESSIBLE
WHERE INDICATED.
1/2"1/2" -
1" --
REMARKS
4. REFER TO ARCHITECTURAL DRAWING FOR PLUMBING FIXTURE LOCATION AND MOUNTING HEIGHT.
1.
PLUMBING FIXTURE SCHEDULE
1 1/2"
WATER HAMMER ARRESTOR (HA-1) : JAY R. SMITH, 5220 SERIES, 1" CONNECTION, PISTON TYPE. WITH EPDM
PSIG. UNIT TO COMPLY WITH ANSI 1010 WATER HAMMER ARRESTOR. PROVIDE 12X12 STAINLESS STEEL ACCESS
PANEL.
WATER CLOSET: WC-1
FURNISH AMERICAN STANDARD "AFWALL FLOWISE" NO. 2856.128 WALL-MOUNT, ELONGATED, WHITE, VITREOUS
CHINA, TOP SPUD, 1.28 GPF, EVERCLEAN SURFACE. FLUSH VALVE SHALL BE 1" HARDWIRED SELECTRONIC TOP
SPUD, 'SELECTRONIC' SENSOR ACTIVATED FLUSHOMETER WITH OVERRIDE BUTTON, NON-HOLD OPEN INTEGRAL
SOLENOID OPERATOR, WITH NO VISIBLE FASTENERS, BACK-CHECK ANGLE VALVE, VANDAL RESISTANT STOP
CAP, VACUUM BREAKER. PROVIDE NEW CARRIER SUPPORTS AND ANCHORS AS RECOMMENDED BY FIXTURE
MANUFACTURER. FURNISH TOILET SEAT AND COVER, WHITE COLOR. PROVIDE FLUSH VALVE WITH FLUSH LEVER
ON THE WIDE SIDE FOR ACCESSIBLE (ADA) ACCESS. PROVIDE POWER KIT WITH TRANSFORMER.
URINALUR-1 2"WALL MOUNTED, ADA ACCESSIBLE
WHERE INDICATED.1" --1 1/2"
4.
7.
8.
9.
3.
URINAL: UR-1
PROVIDE TOTO NO. UT105UG, WALL-MOUNT, WHITE, VITREOUS CHINA WITH 'CeFiONtect' CERAMIN GLAZE, ADA
COMPLIANT, MEETS ANSI 0.125 GPF, HIGH EFFICIENCY FLUSH REQUIREMENTS, SIPHON JET FLUSH ACTION. FLUSH
VALVE CHROME FINISHED FLUSHOMETER, HARDWIRED 'SELECTRONIC' SENSOR ACTIVATED FLUSHOMETER WITH
OVERRIDE BUTTON, WITH NO VISIBLE FASTENERS, BACK-CHECK ANGLE VALVE, VANDAL RESISTANT STOP CAP,
VACUUM BREAKER, ANGLE STOP WITH BACKFLOW PREVENTER, HIGH BACK PRESSURE VACUUM BREAKER. PROVIDE
FIXTURE CARRIER OR WALL SUPPORT AS RECOMMENDED BY THE MANUFACTURER. PROVIDE TRAP PRIMER TAIL
PIECE 'TP' VBF-72 FOR FLOOR DRAIN. PROVIDE WATER SUPPLY PLUMBING TO FLOOR DRAIN.
ALL LAVATORY FAUCETS SHALL BE FITTED WITH AN APPROVED FLOW CONTROL DEVICE ALLOWING A MAXIMUM OF 0.5 GPM. PUBLIC3.
ALL URINALS SHALL USE A MAXIMUM OF 0.125 GALLONS PER FLUSH.
FLOOR DRAIN FD-1 : ZURN Z415S-ZB-P, 5"X5" DRAIN, DURA-COATED CAST IRON BODY WITH BOTTOM OUTLET,
COMBINATION INVERTIBLE MEMBRANE CLAMP AND ADJUSTABLE COLLAR WITH SEEPAGE SLOTS, POLISHED
NICKLE BRONZE, LIGHT DUTY, INVERTER STRAINER WITH TRAP PRIMER CONNECTION. PROVIDE TRAP PRIMER
WITH SLOAN VBF-72-A WITH VACUUM BREAKER FROM CLOSIEST WATER CLOSET FLUSHOMETER.
5.
FLOOR DRAINFD-1 3"PROVIDE TRAP PRIMER.
1/2" --1 1/2"
PROVIDE CLEANOUTS WITH BRASS CAPS AND SCREWS SAME SIZE AS PIPE AT THE ENDS OF BRANCHES ON SOIL
AND WASTE PIPING, AND IN SUCH OTHER PORTIONS OF THE PIPING WHERE RUN IS OVER 50'-0". BRASS CLEANOUTS
SHALL BE SOLID NUT CONSTRUCTION
10.
JANITOR'S SINKS-1 2 - 1/2"
11.
1/2"
DRINKING FOUNTAINDF-1 2 1/2"1 1/2" -
-
-
SHOWER SHO-1: PROVIDE SHOWER HEAD KOHLER K-72425 WITH BRASS THERMOSTATIC VALVE TRIM SET
K-T10940 WITH BLADE HANDLE AND ACCESSORIES, AND SHOWER COLUMN K-45904. SHOWER SHALL BE
RESTRICTED TO 2.0 GPM.
12.
SINK, ADA COMPLIANT (S-2): PROVIDE COUNTER TOP 18-GAUGE, SEAMLESS FORMED SINGLE COMPARTMENT,
STAINLESS STEEL SINK, UNDER-MOUNT ELKAY 'ELUHAD281645', 31"X22"X4 1/5" DEEP, SATIN DECK FINISH, LUSTER
BASIN FINISH WITH UNDERCOATING, OFF-CENTERED REAR CONNECTION AND ONE CENTERED FAUCET HOLE,
ADA COMPLIANT AND SHALL MEET ASME A112.19.3/CSA B45.4, ICC/ANSI A117.1. PROVIDE KOHLER 'PURIST' K-7507,
ADA COMPLIANT, ONE-PIECE, SELF CONTAINED CERAMIC DISC VALVE ALLOW BOTH VOLUME AND TEMPERATURE
CONTROL, TEMPERATURE MEMORY, HIGH-TEMPERATURE LIMIT SETTING. METAL LEVER OPERATION HANDLE,
DECK MOUNTED, INTEGRAL VACUUM BREAKER, 8" SWING SPOUT REACH WITH ROTATING SPOUT, 1.8 GPM
MAXIMUM FLOW RATE. FAUCET SHALL MEET THE FOLLOWING CODES AND STANDARDS: ASME A112.18.1/CSA
B125.1, ACC/ANSI A117, NSF 61 AND CALIFORNIA AB1953 'LEAD-FREE' REQUIREMENTS. PROVIDE CHROME FINISH,
1-1/2" TAILPIECE, BRASS CRAFT NO. 0010 1-1/2" P-TRAP, BRASS CRAFT NO. R1512A CHROME FLEXIBLE SUPPLIES,
TRUEBRO HANDI-LAV GUARD INSULATION KIT.
13.
BAR SINKS-2 2 - 1/2"1/2" -
JANITOR'S SINK S-1:
.FLOOR MOUNTED MOP SINK 'FLORWELL' SERVICE SINK ENAMELED CAST IRON, 3" OUTLET, CORNER MODEL WITH
7745.811 REMOVABLE VINYL RIM GUARD, 28"X28"X13" DEEP BOWL, 7721.038 FLAT GRID DRAIN MEETS OR
EXCEEDS THE FOLLOWING SPECIFICATIONS ASME A1112.19.1 FOR CAST IRON PLUMBING FIXTURES. PROVIDE
AMERICAN STANDARD MODEL EXPOSED YOKE WALL-MOUNT UTILITY FAUCET WITH TOP BRACE 6" CAST BRASS
SPOUT WITH VACUUM BREAKER, CERAMIC DISC VALVE, INTEGRAL SUPPLY STOPS, OFFSET SHANKS WITH
INTEGRAL CHECK VALVES, VANDAL-RESISTANT, METAL LEVER HANDLES, BUCKET HOOK, 3/4" THREADED HOSE
END, 1/2" NPT FEMALE INLETS, ADJUSTABLE CENTERS-TO-CENTERS: 6" - 10".
LAVATORY: LAV-1
PROVIDE AMERICAN STANDARD DECORUM 9024.011EC, CENTER HOLE WITH RIGHT SOAP DISPENSER HOLE, WALL-HUNG
LAVATORY, VITREOUS CHINA 20" X 18" WITH RIGHT HAND BOBNICK B8263.18 SOAP DISPENSER WITH STARTER KIT SOAP
REFILL AND BATTERY PACK. PROVIDE SERIN SENSOR-OPERATED FAUCET, ADA COMPLIANT, INFRARED SENSOR
OPERATED ELECTRONIC, 24VAC HARDWIRED AC POWERED, 0.5 GPM, CHROME FINISH, 120 VAC/24 VAC TRANSFORMER,
VANDAL-RESISTANT, SOLID BRASS CONSTRUCTION. 'LEAD-FREE' CSA AB1953-2006, CAL GREEN WITH THERMAL
CONTROLLER /MIXING #2605XTMV-1070 WITH STAINLESS STEEL FLEXIBLE HOSES, DISCHARGE ON DEMAND UP TO 60
SECONDS WHILE ACTIVATED. PROVIDE TAILPIECE, BRASS CRAFT NO. 0010 1-1/4" P-TRAP, BRASS CRAFT NO. R1512A
CHROME FLEXIBLE SUPPLIES, TRUEBRO HANDI-LAV GUARD INSULATION KIT. PROVIDE NEW CONCEALED FIXTURE
SUPPORT ARMS OR WALL BRACKETS AS RECOMMENDED BY THE FIXTURE MANUFACTURER. PROVIDE POWER KIT WITH
TRANSFORMER.
14. SINK S-3: DROP-IN SINK LAB FIXTURE 16-GA STAINLESS STEEL TYPE 316, POLISHED FINISH, FULLY COATED
UNDERSIDE BACK-RIGHT DRAIN CENTER. FURNISH (1)28"x16"X12"DEEP SINK 'JUST' SLXD-2131-16-GR . FAUCET
SHALL BE ZURN FAUCET MODEL Z826C4-XL, DECK MOUNT, COMBINATION HOT AND COLD WATER, WITH 8"
RIGIS/SWING SPOUT, LABORATORY SERRATED NOZZLE, VANDAL PROOF 4" WRISTBLADE FOR HANDLE WITH HOT
AND COLD SUPPLY, LOW COMPRESSION OPERATING CARTRIDGE, TEFLON SEAL RATED AT 150 PSI WORKING
PRESSURE, ATMOSPHERIC VACUUM BREAKER, CHROME PLATE FINISH. PROVIDE 'GLECO TRAP' PACKAGE MODEL
GT64 FOR SOLID REMOVAL.
PLUMBING FIXTURES SPECIFICATIONS
DRINKING FOUNTAIN: (ADA ACCESSIBLE) DF-1
PROVIDE ELKAY MODEL LZSTLDDWS FOUNTAINS WITH INTEGRAL BOTTLE FILLING STATION. UNIT SHALL BE
STAINLESS STEEL CONSTRUCTION WITH PLASTIC ABS ALCOVE, UNIT SHALL HAVE SENSOR-ACTIVATION WITH AN
AUTO 20-SECOND SHUT-OFF TIMER. BOTTLE FILLER SHALL PROVIDE 1.5 GPM FLOW RATE WITH LAMINAR FLOW,
INCLUDE THE 'WATERSENTRY PLUS 3000-GALLON' CAPACITY FILTER, CERTIFIED TO NSF/ANSI 42 AND 53, WITH
VISUAL MONITOR TO INDICATE WHEN REPLACEMENT IS NECESSARY. UNIT SHALL INCLUDE INTEGRATED SILVER
ION ANTI-MICROBIAL PROTECTION IN KEY AREAS. UNIT SHALL MEET ADA GUIDELINES. UNIT SHALL BE LEAD-FREE
DESIGN WHICH IS CERTIFIED TO NSF/ANSI 61 AND 372 AND MEETS FEDERAL AND STATE LOW-LEAD
REQUIREMENTS. UNIT SHALL BE CERTIFIED TO UL399 AND CAN/CSA 22.2 NO. 120. PROVIDE P-TRAP, WATER
STOPS, IN-WALL SUPPORTS MOUNTING PLATE ASSEMBLY AND HARDWARES. INSTALL PER MANUFACTURER'S
REQUIREMENTS. MODIFY EXISTING PLUMBING AND EXTEND TO THE NEW LOCATION. VERIFY SIZE AND LOCATION
OF POINT OF CONNECTION. TO EXISTING.
14.
WATER CLOSET: WC-2(ADA)
FURNISH AMERICAN STANDARD MADERA 16 1/2" "FLOWISE" NO. 3461.001, 1.28 GPF FLOOR-MOUNT, ELONGATED,
WHITE, VITREOUS CHINA, TOP SPUD, 1.28 GPF, EVERCLEAN SURFACE. FLUSH VALVE SHALL BE 1" HARD-WIRED
SELECTRONIC, 120 VAC PK00.HAC POWER SUPPLY TOP SPUD, SENSOR ACTIVATED FLUSHOMETER WITH
OVERRIDE BUTTON, NON-HOLD OPEN INTEGRAL SOLENOID OPERATOR, WITH NO VISIBLE FASTENERS,
BACK-CHECK ANGLE VALVE, VANDAL RESISTANT STOP CAP, VACUUM BREAKER. PROVIDE NEW CARRIER
SUPPORTS AND ANCHORS AS RECOMMENDED BY FIXTURE MANUFACTURER. FURNISH TOILET SEAT AND COVER,
WHITE COLOR. PROVIDE FLUSH VALVE WITH FLUSH LEVER ON THE WIDE SIDE FOR ACCESSIBLE (ADA) ACCESS.
PROVIDE POWER KIT WITH TRANSFORMER.
2.
REVISIONS
SHEET NUMBER
SHEET TITLE
N&T JOB #
ISSUE DATE
729 Heinz AvenueBerkeley, CA 94710
tel 510.542.2200fax 510.542.2201
SEAL
APPROVALS
1901 HEARST ST.
BERKELEY CA 94704
21603.00
12/19/18
# DATE DESCRIPTION
EDDIEPADILLA
274 Devonshire Street
SHOWER DRAIN FD-2 : ZURN Z415B-HD, 2" DRAIN, DURA-COATED CAST IRON BODY WITH BOTTOM OUTLET,
COMBINATION INVERTIBLE MEMBRANE CLAMP AND ADJUSTABLE COLLAR WITH SEEPAGE SLOTS, POLISHED
NICKLE BRONZE, HEAVY DUTY, INVERTER STRAINER WITH TRAP PRIMER CONNECTION. PROVIDE TRAP PRIMER
WITH SLOAN VBF-72-A WITH VACUUM BREAKER FROM CLOSIEST WATER CLOSET FLUSHOMETER.
6.
1(E)LAV
(E)LAV
(E)LAV
(E)LAV
(E)WC
1
1
1
2
(E)WC
2
(E)WC
2
(E)WC
2
(E)WC
2
(E)UR3
5(E)SINK
5(E)SINK 5(E)SINK
5(E)SINK
(E)WC 2
(E)WC2
(E)LAV 1
(E)LAV1
6(E)JAN
SINK
WORKSHOP
111
STOR.
112
MECH. RM.
113
ART
SHOP
114
HALL
115
STOR.
117
ELECT.
118
STOR.
122
HALL
123
STOR.
124
125
126
REC.
127
TRASH
128
KITCHEN
129
(N) COFFEE BAR
131
DINING
ROOM
132
MULTI-PURPOSEROOM
136
STOR
138
LOUNGE
144
WOMEN
161
HALL 142
GAME ROOM B
101GAME ROOM A
102
HEALTH
ROOM
103A
TOILET105
HEALTH
OFFICE 104
HALL
106
STOR.
107
STOR.
108
ELEV
EQUIP
109
(N) MEETING RM
103B
FRONT
DESK154
ADVISORY
COUNCIL
OFFICE
155
ENTRY
143
HALL
146
ADMIN
OFC
153
DIRECTOR
OFC
147
COPY
148STOR.
149
STAFF
LOUNGE152
TOILET 151
STOR
141
STAGE
139
MTG RM
156
MEN
157
ELEV
000
OFFICE 3
116 C
5 (E)SINK
(E)LAV (TO REMAIN)
(E)DF1
5 (E)SINK
1
A
D
5
7
B
C
3 6
42
E
F
C.5
1
P2.11
FIRST FLOOR PLAN - PLUMBING DEMOLITIONscale: 1/8" = 1'-0"
1
2
6
3
4
5
DEMOLITION KEYED NOTES:
REMOVE AND DISPOSE EXISTING (E) JANITOR SINK AND ASSOCIATED
PLUMBING, SUPPORTS, ANCHORS. MODIFY PLUMBING FOR SANITARY
WASTE & VENT, HOT AND COLD WATER FOR THE NEW FLOOR MOUNTED
JANITOR SINK.
REMOVE AND DISPOSE EXISTING (E)URINAL AND ASSOCIATED
PLUMBING, SUPPORTS AND ANCHORS.
REMOVE AND DISPOSE EXISTING (E) COUNTER SINK AND ASSOCIATED ,
PLUMBING, SUPPORTS, ANCHORS. CAP PIPE BRANCHES AT BRANCH
MAIN.
REMOVE AND DISPOSE EXISTING (E) LAVATORY AND ASSOCIATED
PLUMBING, SUPPORTS, ANCHORS. MODIFY PLUMBING FOR SANITARY
WASTE & VENT, HOT AND COLD WATER FOR THE NEW LAVATORY.
REMOVE AND DISPOSE EXISTING (E) WATER CLOSET AND ASSOCIATED
PLUMBING, SUPPORTS, ANCHORS. MODIFY PLUMBING FOR SANITARY
WASTE & VENT, HOT AND COLD WATER FOR THE NEW WATER CLOSET.
REMOVE AND DISPOSE EXISTING (E) FLOOR DRAIN. MODIFY PLUMBING
FOR SANITARY WASTE & VENT FOR THE NEW FLOOR DRAIN.
REVISIONS
SHEET NUMBER
SHEET TITLE
N&T JOB #
ISSUE DATE
729 Heinz AvenueBerkeley, CA 94710
tel 510.542.2200fax 510.542.2201
SEAL
APPROVALS
1901 HEARST ST.
BERKELEY CA 94704
21603.00
12/19/18
# DATE DESCRIPTION
EDDIEPADILLA
274 Devonshire Street
7 REMOVE AND DISPOSE EXISTING (E) DRINKING FOUNTAIN AND
ASSOCIATED PLUMBING, SUPPORTS AND ANCHORS.
OPEN TO BELOW
1
A
D
5
7
B
C
3 6
42
E
F
1
1
2
2
4 POC. CONNECT TO
EXISTING IN
MECHANICAL ROOM
POC. CONNECT TO
EXISTING IN THE
KITCHEN.
EXISTING GAS METER AND
PRESSURE REGULATOR
TO REMAIN.
4
4
4
4
4 4
4
5
ELEV
000
LIBRARY
202
WOMEN
203
SHW
204
JAN
205
MEN
206
SHW
207
HALL
208
STOR.
209
CLASSROOM C
210
CLASSROOM B
211
CLASSROOM A
212
HALL
201
1
P2.12
SECOND FLOOR PLAN -PLUMBING DEMOLITIONscale: 1/8" = 1'-0"
DEMOLITION KEYED NOTES:REMOVE AND DISPOSE EXISTING (E) LAVATORY AND ASSOCIATED
PLUMBING, SUPPORTS, ANCHORS. MODIFY PLUMBING FOR SANITARY
WASTE & VENT, HOT AND COLD WATER FOR THE NEW LAVATORY.
REMOVE AND DISPOSE EXISTING (E) WATER CLOSET AND ASSOCIATED
PLUMBING, SUPPORTS, ANCHORS. MODIFY PLUMBING FOR SANITARY
WASTE & VENT, HOT AND COLD WATER FOR THE NEW WATER CLOSET.
REMOVE AND DISPOSE EXISTING (E) FLOOR DRAIN. MODIFY PLUMBING
FOR SANITARY WASTE & VENT FOR THE NEW FLOOR DRAIN.3
2
1
REMOVE AND DISPOSE EXISTING GAS PIPING ON ROOF INCLUDING
ASSOCIATED VALVES, PIPE SUPPORT AND SUPPORT ANCHORS.
REROUTE GAS PIPING IN THE BUILDING CEILING SPACE AS SHOWN ON
P2.21. VERIFY EXACT PIPE SIZE AND LOCATION AT POINT OF
CONNECTION (POC).
4
REMOVE AND DISPOSE EXISTING (E) DRINKING FOUNTAIN AND
ASSOCIATED PLUMBING, SUPPORTS, ANCHORS. MODIFY SUPPORT AND
PLUMBING FOR SANITARY WASTE & VENT, HOT AND COLD WATER FOR
THE NEW DRINKING FOUNTAIN.
5
REVISIONS
SHEET NUMBER
SHEET TITLE
N&T JOB #
ISSUE DATE
729 Heinz AvenueBerkeley, CA 94710
tel 510.542.2200fax 510.542.2201
SEAL
APPROVALS
1901 HEARST ST.
BERKELEY CA 94704
21603.00
12/19/18
# DATE DESCRIPTION
EDDIEPADILLA
274 Devonshire Street
2
7
2
2
3
3
3
3
6
3
3
5
3
2
2
2
6
6
2
3
32
10
10
10
10
10
10
10
10
10
UP
1
1
A A
D
5
7
7
B B
C
3 6
42
2
E
F
C.5
UP
UP
11S-3 11S-3
1
7
12
1
WORKSHOP
111
STOR.
112
MECH. RM.
113
ART
SHOP
114
HALL
115
ADMIN
116 A
STOR.
117
ELECT.
118
MANAGERS OFC
119
STOR.
122
HALL
123STOR.
124
FREEZER
125
REF.
126
REC.
127
TRASH
128
KITCHEN
129
(N) COFFEE BAR
131
DINING
ROOM
132
STOR.
133
STOR.
134STOR.
135
STOR.
137
MULTI-PURPOSEROOM
136
STOR138
LOUNGE
144
WOMEN
161
HALL 142
GAME ROOM B
101GAME ROOM A
102
HEALTH
ROOM
103A
TOILET105
HEALTH
OFFICE 104
HALL
106STOR.
107
STOR.
108
ELEV
EQUIP
109
(N) MEETING RM
103B
FRONT
DESK
154
ADVISORY
COUNCIL
OFFICE
155
ENTRY
143
HALL
146
ADMIN
OFC
153
DIRECTOR
OFC
147
COPY
148STOR.
149
STAFF
LOUNGE152
TOILET151
STOR
141
STAGE
139
MTG RM 156
MEN
157
ELEV
000
OFFICE 2
116 B
OFFICE 3
116 C
JAN2
1
P2.21
FIRST FLOOR PLAN - PLUMBINGscale: 1/8" = 1'-0"
CONSTRUCTION KEYED NOTES:EXISTING PLUMBING TO REMAIN.
PROVIDE NEW FLOOR DRAIN. MODIFY AND EXTEND EXISTING PLUMBING
AS REQUIRED FOR COLD WATER, SANITARY WASTE DRAIN AND VENTS.
PROVIDE TRAP PRIMER. VERIFY EXISTING PIPING CONNECTION
CONDITION, LOCATION AND SIZES. PROVIDE SUPPORT AND ANCHORS.
SEE DRAWING P3.00 FOR SCHEDULED REQUIREMENTS AND PIPING
CONNECTIONS.
PROVIDE NEW BAR SINK S-1. MODIFY AND EXTEND EXISTING PLUMBING
AS REQUIRED FOR HOT & COLD WATER, SANITARY WASTE DRAIN AND
VENTS. VERIFY EXISTING PIPING CONNECTION CONDITION, LOCATION
AND SIZES. PROVIDE SUPPORT AND ANCHORS. SEE DRAWING P3.01 FOR
SCHEDULED REQUIREMENTS AND PIPING CONNECTIONS.
PROVIDE NEW SHOWER AND DRAIN. MODIFY AND EXTEND EXISTING
PLUMBING AS REQUIRED FOR HOT AND COLD WATER, SANITARY WASTE
DRAIN AND VENTS. VERIFY EXISTING PIPING CONNECTION CONDITION,
LOCATION AND SIZES. PROVIDE SUPPORT AND ANCHORS. SEE DRAWING
P1.01 FOR SCHEDULED REQUIREMENTS AND PIPING CONNECTIONS.
PROVIDE NEW WALL MOUNTED LAVATORY. MODIFY AND EXTEND
EXISTING PLUMBING AS REQUIRED FOR HOT AND COLD WATER,
SANITARY WASTE DRAIN AND VENTS. VERIFY EXISTING PIPING
CONNECTION CONDITION, LOCATION AND SIZES. PROVIDE SUPPORT
AND ANCHORS. SEE DRAWING P3.0 FOR SCHEDULED REQUIREMENTS
AND PIPING CONNECTIONS.
PROVIDE NEW WALL MOUNTED URINAL. MODIFY AND EXTEND EXISTING
PLUMBING AS REQUIRED FOR COLD WATER, SANITARY WASTE DRAIN
AND VENTS. VERIFY EXISTING PIPING CONNECTION CONDITION,
LOCATION AND SIZES. PROVIDE SUPPORT AND ANCHORS. SEE DRAWING
P3.00 FOR SCHEDULED REQUIREMENTS AND PIPING CONNECTIONS.
PROVIDE NEW WALL MOUNTED WATER CLOSET RESTROOM. MODIFY
AND EXTEND EXISTING PLUMBING AS REQUIRED FOR COLD WATER,
SANITARY WASTE DRAIN AND VENTS. VERIFY EXISTING PIPING
CONNECTION CONDITION, LOCATION AND SIZES. PROVIDE SUPPORT
AND ANCHORS. SEE DRAWING P3.00 FOR SCHEDULED REQUIREMENTS
AND PIPING CONNECTIONS.
REPLACE EXISTING FLOOR DRAIN WITH ZURN DECK RECEPTOR MODEL
Z127. MODIFY EXISTING PLUMBING AS NECESSARY.
PROVIDE NEW ADA COMPLIANT HI-LO DRINKING FOUNTAIN COMPLETE
WITH WALL BRACKET AND SUPPORTS. MODIFY AND EXTEND EXISTING
PLUMBING AS REQUIRED FOR COLD WATER, SANITARY WASTE DRAIN
AND VENTS. VERIFY EXISTING PIPING CONNECTION CONDITIONS,
LOCATION AND SIZES. SEE DRAWING P3.0 FOR SCHEDULED
REQUIREMENTS AND PIPING CONNECTIONS. REFER TO ARCHITECTURAL
DRAWING FOR ADA LAVATORY FOR EXACT LOCATION AND MOUNTING
HEIGHT. ADJUST PIPING AND SUPPORT ACCORDINGLY.
REMOVE GAS PIPING DISTRIBUTION ON ROOF. REROUTE EXISTING GAS
UNDER THE ROOF EAVE AROUND THE BUILDINGSTRUCTURE.
PROVIDE NEW DROP-IN SINK S-3. MODIFY AND EXTEND EXISTING
PLUMBING AS REQUIRED FOR HOT & COLD WATER, SANITARY WASTE
DRAIN AND VENTS. VERIFY EXISTING PIPING CONNECTION CONDITION,
LOCATION AND SIZES. PROVIDE SUPPORT AND ANCHORS. SEE DRAWING
P3.01 FOR SCHEDULED REQUIREMENTS AND PIPING CONNECTIONS.
PROVIDE 'GLECO TRAP' PACKAGE MODEL GT64 FOR SOLID REMOVAL.
_______1
EXISTING HOSE BIBB IN TRASH ENCLOSURE TO REMAIN.
REVISIONS
SHEET NUMBER
SHEET TITLE
N&T JOB #
ISSUE DATE
729 Heinz AvenueBerkeley, CA 94710
tel 510.542.2200fax 510.542.2201
SEAL
APPROVALS
1901 HEARST ST.
BERKELEY CA 94704
21603.00
12/19/18
# DATE DESCRIPTION
EDDIEPADILLA
274 Devonshire Street
SHO-1
3
WC-1
ADA
LAV-1
ADA
LAV-1
ADA
2
4
4
2
3
(E)JAN
SINK1
7
OPEN TO BELOW
4
2"FD 9
2"FD-2 9
2"FD-2
9
2"FD 9
2"WCO
2"W, 1"CW
(E)4"W AND
(4) VTR
2"V
AP
1" SHUTOFF
VALVE
2"FCO
2"FCO 2"W
2"W
2"W
2"W
1 1/2"V
1 1/2"V
1 1/2"V
1 1/2"V
2"W
1
P2.22
SECOND FLOOR PARTIAL PLAN - PLUMBINGscale: 1/4" = 1'-0"
CONSTRUCTION KEYED NOTES:EXISTING PLUMBING TO REMAIN.
PROVIDE NEW WALL MOUNTED LAVATORY. MODIFY AND EXTEND
EXISTING PLUMBING AS REQUIRED FOR HOT AND COLD WATER,
SANITARY WASTE DRAIN AND VENTS. VERIFY EXISTING PIPING
CONNECTION CONDITION, LOCATION AND SIZES. PROVIDE SUPPORT
AND ANCHORS. SEE DRAWING P3.0 FOR SCHEDULED REQUIREMENTS
AND PIPING CONNECTIONS.
PROVIDE NEW WALL MOUNTED WATER CLOSET RESTROOM. MODIFY
AND EXTEND EXISTING PLUMBING AS REQUIRED FOR COLD WATER,
SANITARY WASTE DRAIN AND VENTS. VERIFY EXISTING PIPING
CONNECTION CONDITION, LOCATION AND SIZES. PROVIDE SUPPORT
AND ANCHORS. SEE DRAWING P3.00 FOR SCHEDULED REQUIREMENTS
AND PIPING CONNECTIONS.
PROVIDE NEW SHOWER AND DRAIN. MODIFY AND EXTEND EXISTING
PLUMBING AS REQUIRED FOR HOT AND COLD WATER, SANITARY WASTE
DRAIN AND VENTS. VERIFY EXISTING PIPING CONNECTION CONDITION,
LOCATION AND SIZES. PROVIDE SUPPORT AND ANCHORS. SEE DRAWING
P1.01 FOR SCHEDULED REQUIREMENTS AND PIPING CONNECTIONS.
PROVIDE NEW FLOOR MOUNTED JANITOR SERVICE SINK. MODIFY AND
EXTEND EXISTING PLUMBING AS REQUIRED FOR HOT AND COLD WATER,
SANITARY WASTE DRAIN AND VENTS. VERIFY EXISTING PIPING
CONNECTION CONDITION, LOCATION AND SIZES. PROVIDE SUPPORT
AND ANCHORS. SEE DRAWING P3.0 FOR SCHEDULED REQUIREMENTS
AND PIPING CONNECTIONS.
EXISTING JANITOR SINK TO REMAIN.
REMOVE AND DISPOSE EXISTING DRINKING FOUNTAIN. PROVIDE NEW
ADA COMPLIANT HI-LO DRINKING FOUNTAIN COMPLETE WITH WALL
BRACKET AND SUPPORTS. MODIFY AND EXTEND EXISTING PLUMBING
AS REQUIRED FOR COLD WATER, SANITARY WASTE DRAIN AND VENTS.
VERIFY EXISTING PIPING CONNECTION CONDITIONS, LOCATION AND
SIZES. SEE DRAWING P3.0 FOR SCHEDULED REQUIREMENTS AND PIPING
CONNECTIONS. REFER TO ARCHITECTURAL DRAWING FOR ADA
LAVATORY FOR EXACT LOCATION AND MOUNTING HEIGHT. ADJUST
PIPING AND SUPPORT ACCORDINGLY.
PROVIDE NEW WALL MOUNTED URINAL RESTROOM. MODIFY AND
EXTEND EXISTING PLUMBING AS REQUIRED FOR COLD WATER,
SANITARY WASTE DRAIN AND VENTS. VERIFY EXISTING PIPING
CONNECTION CONDITION, LOCATION AND SIZES. PROVIDE SUPPORT
AND ANCHORS. SEE DRAWING P3.00 FOR SCHEDULED REQUIREMENTS
AND PIPING CONNECTIONS.
PROVIDE NEW FLOOR DRAIN. MODIFY AND EXTEND EXISTING PLUMBING
AS REQUIRED FOR SANITARY WASTE DRAIN AND VENTS. PROVIDE 3/8"
TRAP PRIMER. CONNECT TO NEAREST WATER CLOSET FLUSH VALVE
WITH SLOAN VBF-72-A BREAKER TRAP PRIMER. PROVIDE SUPPORT AND
ANCHORS. SEE DRAWING P1.01 FOR SCHEDULED REQUIREMENTS AND
PIPING CONNECTIONS.
REVISIONS
SHEET NUMBER
SHEET TITLE
N&T JOB #
ISSUE DATE
729 Heinz AvenueBerkeley, CA 94710
tel 510.542.2200fax 510.542.2201
SEAL
APPROVALS
1901 HEARST ST.
BERKELEY CA 94704
21603.00
12/19/18
# DATE DESCRIPTION
EDDIEPADILLA
274 Devonshire Street
LAV-12
WC-1
WC-1( ADA)
DF-1
UR-1
LAV-12
3
WC-1
WC-1
3
3
8
LAV-1 2
LAV-1 2
WC-13
WC-13
5
WC-1
ADA3
7
3"W
2"WCO
4"VTR
2"WCO
3"FCO
3"W
4"WCO
2 1/2"V2 1/2"V
2"CW, 3/4"HW2"CW, 3/4"HW
2"CW, 4"W, 2 12"V
2"CW, 4"W, 2 12"V
3"FD3"FD
3"3"2"V 2"V 44
HA-1 9
AP
HB-110HB-1 10
1/2"CW, 1/2"HW (TYP)
3"FCO
1
P3.01
FIRST FLOOR MAIN RESTROOM PLAN - PLUMBINGscale: 1/4" = 1'-0"
CONSTRUCTION KEYED NOTES:EXISTING PLUMBING TO REMAIN.
PROVIDE NEW FLOOR DRAIN. MODIFY AND EXTEND EXISTING PLUMBING
AS REQUIRED SANITARY WASTE DRAIN AND VENTS. PROVIDE TRAP
PRIMERSANITARY WASTE DRAIN AND VENTS. PROVIDE 3/8" TRAP
PRIMER. CONNECT TO NEAREST WATER CLOSET FLUSH VALVE WITH
SLOAN VBF-72-A BREAKER TRAP PRIMER.PROVIDE SUPPORT AND
ANCHORS. SEE DRAWING P1.01 FOR SCHEDULED REQUIREMENTS AND
PIPING CONNECTIONS.
PROVIDE NEW WALL MOUNTED LAVATORY. MODIFY AND EXTEND
EXISTING PLUMBING AS REQUIRED FOR HOT AND COLD WATER,
SANITARY WASTE DRAIN AND VENTS. VERIFY EXISTING PIPING
CONNECTION CONDITION, LOCATION AND SIZES. PROVIDE SUPPORT
AND ANCHORS. SEE DRAWING P1.01 FOR SCHEDULED REQUIREMENTS
AND PIPING CONNECTIONS.
PROVIDE NEW WALL MOUNTED URINAL. MODIFY AND EXTEND EXISTING
PLUMBING AS REQUIRED FOR COLD WATER, SANITARY WASTE DRAIN
AND VENTS. VERIFY EXISTING PIPING CONNECTION CONDITION,
LOCATION AND SIZES. PROVIDE SUPPORT AND ANCHORS. SEE DRAWING
P1.01 FOR SCHEDULED REQUIREMENTS AND PIPING CONNECTIONS.
PROVIDE NEW WALL MOUNTED WATER CLOSET RESTROOM. MODIFY
AND EXTEND EXISTING PLUMBING AS REQUIRED FOR COLD WATER,
SANITARY WASTE DRAIN AND VENTS. VERIFY EXISTING PIPING
CONNECTION CONDITION, LOCATION AND SIZES. PROVIDE SUPPORT
AND ANCHORS. SEE DRAWING P1.01 FOR SCHEDULED REQUIREMENTS
AND PIPING CONNECTIONS. PROVIDE NARROW WATER CLOSET
CARRIER ZURN ZN1201-ND4. VERIFY PIPE CHASE SPACE.
PROVIDE NEW ADA COMPLIANT HI-LO DRINKING FOUNTAIN COMPLETE
WITH WALL BRACKET AND SUPPORTS. MODIFY AND EXTEND EXISTING
PLUMBING AS REQUIRED FOR COLD WATER, SANITARY WASTE DRAIN
AND VENTS. VERIFY EXISTING PIPING CONNECTION CONDITIONS,
LOCATION AND SIZES. SEE DRAWING P1.01 FOR SCHEDULED
REQUIREMENTS AND PIPING CONNECTIONS. REFER TO ARCHITECTURAL
DRAWING FOR ADA LAVATORY FOR EXACT LOCATION AND MOUNTING
HEIGHT. ADJUST PIPING AND SUPPORT ACCORDINGLY.
PROVIDE WATER HAMMER ARRESTORS(HA-1). PROVIDE
12"X12" STAINLESS STEEL ACCESS PANEL(AP). SEE
ARCHITECTURAL DRAWINGS FOR DETAILS.
PROVIDE NEW WALL & FLOOR CLEANOUTS WITH ACCESS
PANEL. SEE DRAWING P1.01 FOR SCHEDULED
REQUIREMENTS.
PROVIDE NEW SHUTOFF VALVES FOR CW AND HW.
PROVIDE NEW 12"X12" ACCESS PANEL(AP). SHUTOFF
VALVES.
PROVIDE HOSE BIBB IN RECESS BOX. PROVIDE 12"X12"
STAINLESS STEEL ACCESS PANEL(AP).
REVISIONS
SHEET NUMBER
SHEET TITLE
N&T JOB #
ISSUE DATE
729 Heinz AvenueBerkeley, CA 94710
tel 510.542.2200fax 510.542.2201
SEAL
APPROVALS
1901 HEARST ST.
BERKELEY CA 94704
21603.00
12/19/18
# DATE DESCRIPTION
EDDIEPADILLA
274 Devonshire Street