eeseal fixes emi problems- data ·...

9
Examples of Quell EESeal® EMI Filter Insert MILSTD461 Test Results February 9, 2014

Upload: others

Post on 24-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EESeal fixes EMI Problems- Data · EESeal)23821.8)200nF)Customer)MIL8STD8461)Conducted)Emissions)CE803) baseline) with)EESeal)

Examples  of  Quell  EESeal®  EMI  Filter  Insert  MIL-­‐STD-­‐461  Test  Results  

 February  9,  2014  

Page 2: EESeal fixes EMI Problems- Data · EESeal)23821.8)200nF)Customer)MIL8STD8461)Conducted)Emissions)CE803) baseline) with)EESeal)

Typical  EESeal®  Insert  AGenuaHons,  Single  Capacitor  to  Shell  

Page 3: EESeal fixes EMI Problems- Data · EESeal)23821.8)200nF)Customer)MIL8STD8461)Conducted)Emissions)CE803) baseline) with)EESeal)

Typical  EESeal®  Insert  AGenuaHon,  Dual  Capacitors  to  Shell  (some  connectors  do  not  have  room  to  accomplish  this)  

Page 4: EESeal fixes EMI Problems- Data · EESeal)23821.8)200nF)Customer)MIL8STD8461)Conducted)Emissions)CE803) baseline) with)EESeal)

EESeal  1000pF  Customer  MIL-­‐STD-­‐461  Radiated  Emissions  RE-­‐102  

Page 5: EESeal fixes EMI Problems- Data · EESeal)23821.8)200nF)Customer)MIL8STD8461)Conducted)Emissions)CE803) baseline) with)EESeal)

EESeal  23-­‐21.8  200nF  Customer  MIL-­‐STD-­‐461  Conducted  Emissions  CE-­‐03  

baseline  

with  EESeal  

Page 6: EESeal fixes EMI Problems- Data · EESeal)23821.8)200nF)Customer)MIL8STD8461)Conducted)Emissions)CE803) baseline) with)EESeal)

EESeal  23-­‐21.8  200nF  Customer  MIL-­‐STD-­‐461  Conducted  Emissions  CE-­‐03  

baseline  

with  EESeal  

Page 7: EESeal fixes EMI Problems- Data · EESeal)23821.8)200nF)Customer)MIL8STD8461)Conducted)Emissions)CE803) baseline) with)EESeal)

Real  Customer:      “Thank  you  for  the  second  EESeal  that  you  sent  to  me.  I  received  the  part  yesterday  morning,  just  in  Hme  to  hand  the  part  to  the  BriHsh  engineer  who  was  returning  to  the  UK  yesterday  a[ernoon.  He  says,  ‘brilliant’!      I  have  also  aGached  4  graphics  files.  Plot  908  is  a  Baseline  of  the  performance  of  one  of  our  modules,  while  Plot  909  shows  the  effects  of  adding  one  0.47  uF  EESeal  filter  insert.  This  is  conducted  emission  on  a  28  VDC  power  bus,  tesHng  to  DEF  STAN  59-­‐41,  Method  DCE01.3.”  

EESeal  47nF  Customer  MIL-­‐STD-­‐461  Conducted  Emissions  DCE01.3  

baseline  

with  EESeal  

Page 8: EESeal fixes EMI Problems- Data · EESeal)23821.8)200nF)Customer)MIL8STD8461)Conducted)Emissions)CE803) baseline) with)EESeal)

EESeal  4700pF  Customer  MIL-­‐STD-­‐461  Radiated  Emissions  RE-­‐102  

baseline  

with  EESeal  

Page 9: EESeal fixes EMI Problems- Data · EESeal)23821.8)200nF)Customer)MIL8STD8461)Conducted)Emissions)CE803) baseline) with)EESeal)

EESeal  470pF  Customer  MIL-­‐STD-­‐461  Radiated  Emissions  RE-­‐102