Efficient Use of Energy in CaliforniaPower Electronics Conference

Long Beach, CAOct. 25, 2006

Arthur H. Rosenfeld, Commissioner

California Energy Commission

(916) 654-4930

[email protected]://www.energy.ca.gov/commission/commissioners/rosenfeld.html

or just Google “Art Rosenfeld”

2

1949

3

Energy Intensity in the United States 1949 - 2005

0.0

5.0

10.0

15.0

20.0

25.0

19

49

19

51

19

53

19

55

19

57

19

59

19

61

19

63

19

65

19

67

19

69

19

71

19

73

19

75

19

77

19

79

19

81

19

83

19

85

19

87

19

89

19

91

19

93

19

95

19

97

19

99

20

01

20

03

20

05

tho

us

an

d B

tu/$

(in

$2

00

0)

If intensity dropped at pre-1973 rate of 0.4%/year

Actual (E/GDP drops 2.1%/year)

4

Energy Consumption in the United States 1949 - 2005

0

25

50

75

100

125

150

175

200

1949

1951

1953

1955

1957

1959

1961

1963

1965

1967

1969

1971

1973

1975

1977

1979

1981

1983

1985

1987

1989

1991

1993

1995

1997

1999

2001

2003

2005

Qu

ads/

Yea

r

$ 1.7 Trillion

$ 1.0 Trillion

New Physical Supply = 25 Q

Avoided Supply = 70 Quads in 2005

If E/GDP had dropped 0.4% per year

Actual (E/GDP drops 2.1% per year)

70 Quads per year saved or avoided corresponds to 1 Billion cars off the road

5

How Much of The Savings Come from Efficiency?

Easiest to tease out is cars

– In the early 1970s, only 14 miles per gallons

– Now about 21 miles per gallon

– If still at 14 mpg, we’d consume 75 billion gallons more and pay ~$200 Billion more at 2006 prices

– But we still pay $450 Billion per year

– If California wins the “Schwarzenegger-Pavley” suit, and it is implemented nationwide, we’ll save another $150 Billion per year

Commercial Aviation improvements save another $50 Billion per year Appliances and Buildings are more complex

– We must sort out true efficiency gains vs. structural changes (from smokestack to service economy).

6

How Much of The Savings Come from Efficiency (cont’d)?

Some examples of estimated savings in 2006 based on 1974 efficiencies minus 2006 efficiencies

Beginning in 2007 in California, reduction of “vampire” or stand-by losses

– This will save $10 Billion when finally implemented, nation-wide

Out of a total $700 Billion, a crude summary is that 1/3 is structural, 1/3 is transportation, and 1/3 is buildings and industry.

Billion $

Space Heating 40Air Conditioning 30Refrigerators 15Fluorescent Tube Lamps 5Compact Floursecent Lamps 5Total 95

7

A supporting analysis on the topic of efficiencyfrom Vice-President Dick Cheney

“Had energy use kept pace with economic growth, the nation would have consumed 171 quadrillion British thermal units (Btus) last year instead of 99 quadrillion Btus”

“About a third to a half of these savings resulted from shifts in the economy. The other half to two-thirds resulted from greater energy efficiency”

Source: National Energy Policy: Report of the National Energy Policy Development Group, Dick Cheney, et. al., page 1-4, May 2001

Cheney could have noted that 72 quads/year saved in the US alone, would fuel one Billion cars, compared to a world car count of only 600 Million

8

Energy Intensity -- California and the United States

0

2

4

6

8

10

12

14

16

18

2019

63

1965

1967

1969

1971

1973

1975

1977

1979

1981

1983

1985

1987

1989

1991

1993

1995

1997

1999

2001

2003

year

Inte

nsi

ty (

tho

usa

nd

Btu

s p

er $

mea

sure

d in

yea

r 20

00 $

)

US down to 54% of 1973 intensity

California down to 46% of 1973 intensity

54%

46%

9

Per Capita Electricity Sales (not including self-generation)(kWh/person) (2005 to 2008 are forecast data)

0

2,000

4,000

6,000

8,000

10,000

12,000

14,0001

96

0

19

62

19

64

19

66

19

68

19

70

19

72

19

74

19

76

19

78

19

80

19

82

19

84

19

86

19

88

19

90

19

92

19

94

19

96

19

98

20

00

20

02

20

04

20

06

20

08

California

United States

∆= 4,000kWh/yr

= $400/capita

10

Carbon Dioxide Intensity and Per Capita CO2 Emissions -- 2001 (Fossil Fuel Combustion Only)

0.00

5.00

10.00

15.00

20.00

25.00

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00

intensity (tons of CO2 per 2000 US Dollar)

To

ns

of

CO

2 p

er p

erso

n

Canada Australia

S. Korea

California

Mexico

United States

Austria

Belgium

Denmark

France

Germany

Italy

Netherlands

New Zealand

Switzerland

Japan

11

CO2 Emissions in California Including Electricity Imports1990 - 2004

340

360

380

400

420

440

460

480

1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004

year

Mil

lio

n M

etri

c T

on

s o

f C

O2

14 year growth rate of 1.1%/year

12

20

25

30

35

40

45

50

55

2002 2004 2006 2008 2010 2012 2014 2016

MP

G C

on

ve

rte

d t

o C

AF

E T

est

Cy

cle

Japan

EU

China

Canada California (Pavley)

US (1) dotted lines denote proposed standards(2) MPG = miles per gallon

Australia

~

Comparison of Fuel Economy – Passenger Vehicles

13

Index (1972 = 1.00) of U.S. Energy Use, GDP, Energy Intensity and Carbon Dioxidelast 10-year CO2 growth = 1.3% per year

0.00

0.50

1.00

1.50

2.00

2.50

3.00

19

49

19

51

19

53

19

55

19

57

19

59

19

61

19

63

19

65

19

67

19

69

19

71

19

73

19

75

19

77

19

79

19

81

19

83

19

85

19

87

19

89

19

91

19

93

19

95

19

97

19

99

20

01

20

03

20

05

e/gdp

quads

gdp

CO2 (combustion)1.37

2.71

1.33 (est.)

14

Per Capita Electricity Consumption

0

2,000

4,000

6,000

8,000

10,000

12,000

14,000

1960 1965 1970 1975 1980 1985 1990 1995 2000

year

kW

h/p

ers

on

United States

California

New York

Source: http://www.eia.doe.gov/emeu/states/sep_use/total/csv/use_csv

15

Per Capita Electricity Consumption

0

2,000

4,000

6,000

8,000

10,000

12,000

14,000

16,000

1960

1962

1964

1966

1968

1970

1972

1974

1976

1978

1980

1982

1984

1986

1988

1990

1992

1994

1996

1998

2000

year

kW

h/p

ers

on

Red States 2004 ElectionUnited StatesBlue States 2004 ElectionCalifornia

16

Source: Stabilization Wedges: Pacala and Socolow, Science Vol 305, page 968

Growth = 1.5%/yr

17

Impact of Standards on Efficiency of 3 Appliances

Source: S. Nadel, ACEEE,

in ECEEE 2003 Summer Study, www.eceee.org

75%

60%

25%20

30

40

50

60

70

80

90

100

110

1972 1974 1976 1978 1980 1982 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006

Year

Ind

ex (

1972

= 1

00)

Effective Dates of National Standards

=

Effective Dates of State Standards

=

Refrigerators

Central A/C

Gas Furnaces

SEER = 13

18 Source: David Goldstein

New United States Refrigerator Use v. Time

0

200

400

600

800

1,000

1,200

1,400

1,600

1,800

2,000

1947 1952 1957 1962 1967 1972 1977 1982 1987 1992 1997 2002

Av

era

ge

En

erg

y U

se

pe

r U

nit

So

ld (

kW

h/y

r)

0

5

10

15

20

25

Re

frig

era

tor

vo

lum

e (

cu

bic

fe

et)

Refrigerator Size (cubic ft)

Energy Use per Unit(kWh/Year) 71% reduction in 28 yrs

= 4.4% year

1st Federal Standard 1992

19 Source: David Goldstein

New United States Refrigerator Use v. Time and Retail Prices

0

200

400

600

800

1,000

1,200

1,400

1,600

1,800

2,000

1947 1952 1957 1962 1967 1972 1977 1982 1987 1992 1997 2002

Av

era

ge

En

erg

y U

se

or

Pri

ce

0

5

10

15

20

25

Re

frig

era

tor

vo

lum

e (

cu

bic

fe

et)

Energy Use per Unit(kWh/Year)

Refrigerator Size (cubic ft)

Refrigerator Price in 1983 $

$ 1,270

$ 462

20

New Refrigerator Energy Use: 71% will be saved when stock completely turns over to 2001 Standards

0

50

100

150

200

250

300

At 1974 Efficiency At 2002 Efficiency

Bil

lio

n k

Wh

per

Yea

r

Energy Needed

Energy Needed

Energy Saved

21

Annual Energy Saved vs. Several Sources of Supply

Energy Saved Refrigerator Stds

renewables

100 Million 1 KW PV systems

conventional hydro

nuclear energy

0

100

200

300

400

500

600

700

800

Bil

lio

n k

Wh

/yea

r

22

Value of Energy to be Saved (at 8.5 cents/kWh, retail price) vs. Several Sources of Supply in 2005 (at 3 cents/kWh, wholesale price)

Energy Saved Refrigerator Stds

renewables

100 Million 1 KW PV systems

conventional hydro

nuclear energy

0

5

10

15

20

25

Bill

ion

$ (

US

)/ye

ar

in 2

00

5

23

United States Refrigerator Use, repeated, to compare with

Estimated Household Standby Use v. Time

0

200

400

600

800

1000

1200

1400

1600

1800

2000

1947

1949

1951

1953

1955

1957

1959

1961

1963

1965

1967

1969

1971

1973

1975

1977

1979

1981

1983

1985

1987

1989

1991

1993

1995

1997

1999

2001

2003

2005

2007

2009

Ave

rage

En

ergy

Use

per

Un

it S

old

(k

Wh

per

yea

r)

Refrigerator Use per Unit

1978 Cal Standard

1990 Federal Standard

1987 Cal Standard

1980 Cal Standard

1993 Federal Standard 2001 Federal

Standard

Estimated Standby Power (per house)

24

0

20

40

60

80

100

120

3 Gorges三峡

Refrigerators冰箱

Air Conditioners 空调

TWh

2000 Stds

2000 Stds

2005 Stds

2005 Stds

If Energy Star

If Energy Star

TW

H/Y

ear

1.5

4.5

6.0

3.0

7.5

Val

ue

(bil

lio

n $

/yea

r)

Comparison of 3 Gorges to Refrigerator and AC Efficiency Improvements

Savings calculated 10 years after standard takes effect. Calculations provided by David Fridley, LBNL

Value of TWh

3 Gorges三峡

Refrigerators 冰箱

Air Conditioners

空调

Wholesale (3 Gorges) at 3.6 c/kWh

Retail (AC + Ref) at 7.2 c/kWh

三峡电量与电冰箱、空调能效对比

标准生效后, 10年节约电量

25

Annual Peak Savings from Efficiency Programs and Standards

0

2,000

4,000

6,000

8,000

10,000

12,000

14,0001

97

5

19

76

19

77

19

78

19

79

19

80

19

81

19

82

19

83

19

84

19

85

19

86

19

87

19

88

19

89

19

90

19

91

19

92

19

93

19

94

19

95

19

96

19

97

19

98

19

99

20

00

20

01

20

02

20

03

MW

Appliance Standards

Building Standards

Utility Efficiency Programs at a cost of

~1% of electric bill

~ 22% of Annual Peak in California in 2003

i.e. 22% in 30 years

26

California IOU’s Investment in Energy Efficiency

$0

$100

$200

$300

$400

$500

$600

$700

$800

$900

$1,00019

76

1978

1980

1982

1984

1986

1988

1990

1992

1994

1996

1998

2000

2002

2004

2006

2008

2010

2012

Mill

ions

of

$200

2 pe

r Y

ear

Forecast

Profits decoupled from sales

Performance Incentives

Market Restructuring

Crisis

IRP2% of 2004

IOU Electric Revenues

Public Goods Charges

27

No Load Efficiency Improvements (< 20 W)

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

0 5 10 15 20

Rated Output Power (W)

No

Lo

ad P

ow

er (

W)

CEC/ENERGY STAR EPS StandardNon-Compliant ProductsNon-Compliant AverageCompliant ProductsCompliant Average

1 - 5 W OutputSavings: 0.71 W

5 - 10 W OutputSavings: 1.2 W

10 - 20 W OutputSavings: 1.2 W

0 - 1 W OutputSavings: 0.44 W

28

No Load Efficiency Improvements (< 200 W)

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

0 50 100 150 200

Rated Output Power (W)

No

Lo

ad P

ow

er (

W)

CEC/ENERGY STAR EPS StandardNon-Compliant ProductsNon-Compliant AverageCompliant ProductsCompliant Average

50 - 100 W OutputSavings: 1.2 W

20-50 W OutputSavings: 1.3 W

100 - 200 W OutputSavings: 0.22 W

29

Active Mode Efficiency Improvements (< 20 W output)

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

0 5 10 15 20Rated Output Power (W)

Av

era

ge

Eff

icie

nc

y (

%)

CEC/ENERGY STAR EPS Standard

Compliant Products

Compliant Average

Non-Compliant Products

Non-Compliant Average

1 - 5 watt outputSavings: 0.48 WAnnual sales: 95 MAnnual $ saved: $22 M

5 - 10 watt outputSavings: 0.93 WAnnual shipments: 140 MAnnual $ saved: $58 M

10 - 20 watt outputSavings: 1 WAnnual shipments: 61 MAnnual $ saved: $27 M

0 - 1 watt outputWatts saved: 0.31 WAnnual sales: 95 MAnnual $ saved: $14 M

30Standards for EPS will eventually result in $189 million per year in national electricity savings

Active Mode Efficiency Improvements (< 200 W output)

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

0 50 100 150 200

Rated Output Power (W)

Av

era

ge

Eff

icie

nc

y (

%)

CEC/ENERGY STAR EPS Standard

Compliant Products

Compliant Average

Non-Compliant Products

Non-Compliant Average

20 - 50 watt outputSavings: 1.1 WAnnual sales: 73 MAnn. $ saved: $35 M

50 - 100 watt outputSavings: 1.7 WAnnual shipments: 33 MAnnual $ saved: $18 M

100 - 200 watt outputSavings: 8.3 WAnnual shipments: 9 MAnnual $ saved: $15 M

0 - 20 watt output

Annual sales: 391 MAnnual $ saved: $121 M

EPS Energy Savings Impact

US savings year 1: $189 M or 1.9 billion kWh, about half from no-load, half from active mode. By the 5th year (including growth), we will be saving annually $1 B or 10 BkWh This is the equivalent annual output of 4 typical 500-MW power plants, or taking 1 million cars off the road. Payback time (SPT)– No-load, 1 mo. or Zero;

Active mode, ~1 year.

32

Electronics Research funded by CEC/PIER leading to developing California Standards. 1– at Ecos Consulting

Topics:– External and internal ac-dc power supplies– Dc-dc power supplies; many of them, tiny but inefficient.– Battery-charging supplies; standards work starts late ’07.– Computers, servers, data centers– Televisions, set top boxes and other consumer electronics;

develop test procedures– Plug load studies

Information:www.EfficientPowerSupplies.org www.EfficientProducts.org

Contact:– Chris Calwell - [email protected]

33

Electronics Research funded by CEC/PIER2--- at Lawrence Berkeley National Lab

Topics:

– Power-efficient Ethernet and FireWire links

– Reducing network-induced consumption

– Efficiency specs for network products

– Consumer electronics inter-device controls

– Efficient set-top boxes

– Reducing energy use of hard-wired and builder-installed equipment in new homes

December 2006 to December 2008 Contact:

– Bruce Nordman - [email protected]

34

35

Illuminating Space vs. the Street

36

Critical Peak Pricing (CPP)with additional curtailment option

0

10

20

30

40

50

60

70

80

Pri

ce (

cen

ts/k

Wh

)

Standard TOUCritical Peak PriceStandard Rate

Sunday Monday Tuesday Wednesday Thursday Friday Saturday

Extraordinary Curtailment Signal, < once per year

CPP Price Signal

10x per year

?

Potential Annual Customer Savings:

10 afternoons x 4 hours x 1kw = 40 kWh at 70 cents/kWh = ~$30/year

37

Tariffs being Tested in California Pilot

0.00

0.10

0.20

0.30

0.40

0.50

0.60

0.70

0.80

1:00

2:00

3:00

4:00

5:00

6:00

7:00

8:00

9:00

10:0

0

11:0

0

12:0

0

13:0

0

14:0

0

15:0

0

16:0

0

17:0

0

18:0

0

19:0

0

20:0

0

21:0

0

22:0

0

23:0

00:

00

Hour Ending

$ (U

.S.)

/ K

WH

FLAT RATE

TOU RATE

CPP-F RATE (NON CRITICAL DAY)

CPP-F RATE (CRITICAL DAY)

38

AutoDR - Results

202

33

45

219

71

78

61

61

18

111

52

Avg kW Savings

15%

10%

10%

12%

10%

25%

16%

21%

5%

2%

20%

Avg % Savings

$4,5103 (1)46Chabot

$12,000

$3,312

$375

$5,050

$7,500

$3,620

$2,000

$2,000

$1,614

$12,824

Setup

Cost

4 (1)56Target

0 (2)265USPS

1 (0)65Oracle

4 (1)208Gilead

2 (0)272IKEA

4 (3)110Echelon

1 (3)922530 Arnold

4 (4)8550 Douglas

3 (4)227B of A

4 (0)84ACWD

events(2003-4/2005)

Max kW

SavingCompany

Summary 951 13.4% $57.62 / kW *

* Note: Average setup cost for AC load control is approximately $250.00 / kW

39

Small Customer Demand Response, Retail Pricing Pilot, and Advanced Metering Infrastructure

CPUC and CEC have been testing the impact of “CPP” (Critical Peak Pricing) on demand

– Two summers of tests ($10 M experiment). Results for residential customers

– 12% reduction when faced with critical peak prices and no technology

– 30% to 40% reduction for customers with air conditioning, technology, and a critical peak price.

PG&E and SDG&E will install advanced meters soon, SCE will

follow, starting 2008.

Starting late 2008, ALL new bldgs. must have advanced meters and Programmable Communicating Thermostats (PCTs)

40

Source: Response of Residential Customers to Critical Peak Pricing and Time-of-Use Rates during the Summer of 2003, September 13, 2004, CEC Report.

Residential Response on a typical hot dayControl vs. Flat rate vs. CPP-V Rate

( Hot Day, August 15, 2003, Average Peak Temperature 88.50)kW

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

Noon 2:30 7:30

Controllable Thermostat with CPP-V Rate

Controllable Thermostat with Flat Rate

Control Group

Midnight

CPP Event

CPP rates – Load ImpactsCPP rates – Load Impacts

41

Customer Acceptance of CPP ratesCustomer Acceptance of CPP rates

Should all customers be placed on a dynamic rate and given an option to switch to another rate?

Should dynamic rates be offered to all customers?

DefinitelyProbably

95%

69%

65%

73%

61%

69%

22%

30%

20%

26%

17%

0% 20% 40% 60% 80% 100%

Total

TOU

CPP-F

CPP-V

Info Only

1

1

91%

93%

87%

86%

43%

39%

46%

41%

41%

21%

28%

17%

23%

22%

0% 20% 40% 60% 80%

TOTAL

TOU

CPP-F

CPP-V

Info Only

1

1

64%

67%

63%

64%

63%

Residential participants express a strong interest in having dynamic rates offered to all customers.

Source: Statewide Pricing Pilot: End-of-Pilot Customer Assessment, December 2004, Momentum Market Intelligence.

42

.

This talk available on my web page

Just Google

“Art Rosenfeld”

43

Source: Stabilization Wedges: Pacala and Socolow, Science Vol 305, page 968

Growth = 1.5%/yr