SD 1 PARTITION TYPE GRAPHIC SYMBOLS WALL MOUNTED SMOKE DETECTOR EXHAUST VENT EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE REMOVED NEW CONSTRUCTION EXG 6" VENT. STACK EXG 4" SOIL STACK 3" 2" RELOCATE W/C 2" RELOCATE LAV 1 1/2" BATH 2 POWDER ROOM 4" CO. 4" CO. 3" 2" RELOCATE W/C 2" RELOCATE LAV 1 1/2" 3" 1 1/2" RELOCATE SHOWER MASTER BATH 3" 1-1/2" RELOCATE W/C 2" RELOCATE LAV 1 1/2" 4" CO. 3" 1 1/2" RELOCATE SHOWER 1-1/2" REMOVE LAV 1 1/2" REMOVE HOT TUB 2" LAUNDRY 2" FLOOR DRAIN GREENHOUSE EXG 6" VENT. STACK EXG 4" SOIL STACK PH-F Upper Level PH-F 36th Flr Main Level CO. 1-1/2" 1 1/2" RELOCATE SINK KITCHEN EXIST. HOUSE TRAP RELOCATE DISHWASHER CO. 1-1/2" 1 1/2" NEW SINK GREENHOUSE Roof EAST 73RD STREET 37 STORY BUILDING #300 BLOCK: 1448 LOT: 3 OCCUPANCY CLASS: RES CONSTRUCTION CLASS: 1 AREA OF WORK ON 36TH FLOOR ADJACENT 14 STORY BUILDING ADJACENT 6 STORY BUILDING 100 102.17 100 100 102.17 153.25 51.08 100 51.08 100 25 25 25 EAST 74TH STREET 2ND AVENUE NEIGHBORING 2 STORY BUILDING M GAS METER CELLAR 3/4" RELOCATE GAS RANGE EXISTING GAS RISER APT. 5E KITCHEN EXISTING GAS SHUT-OFF VALVE 36TH FLOOR Push Side 42 min Y 54 min X 24 preferred 60 min 18 min, Pull Side 48 min X Push Side Pull Side NOTE: All doors in alcoves shall comply with the clearances for front approaches. 12" (FIG. 25) (FIG. 25) Clearance of optional enclosure. NOTE: Dashed line indicates dimensional 8 min Knee 6 max Toe 17 min Lavatory Depth 9 min 27 min 29 min 49 max 19 max 17 min clear floor space 30 min 48 min 6 max 38 min 32 max 24 min 38 min 32 max foot area control 24 min 6 max 38 min 48 min back 6 max seat head back wall side wall 38 min 38 min 12 min 12 min 32 max toilet paper 19 min 12 18 min 36 max 32 max clear floor space 18 lav. min 36 min 56 min 48 min min clear floor space lav. 18 16-18 36 min 66 min 48 min 16-18 Clearance Clearance space floor 30 min clear 60 min back foot head 18 min B. Hinge Side Approaches - Swinging Doors A. Front Approaches - Swinging Doors NOTE: y = 48" minimum if door has both a latch and closer. NOTE: x = 36" minimum if y = 60"; x = 42" minimum if y = 54". NOTE: x = 12" if door has both a closer and latch. MANEUVERING CLEARANCES AT DOORS CLEAR FLOOR SPACE AT BATHTUB REINFORCED AREAS FOR GRABS AT BATHTUB CLEAR FLOOR SPACE AT WATER CLOSET REINFORCED AREAS FOR GRAB BARS AT WATER CLOSET CLEAR FLOOR SPACE AND CLEARANCES AT LAVATORIES Y Scale: Consultant Contact Address Phone e-mail ARCHITCTS PLLC 648 Broadway / Suite 402, New York, NY 10012 T.212.254.5210 F.212.254.4523 www.wilkinsonarchitects.com New York : Registered Architect 027917-1 Pennsylvania : Registered Architect 402561 National Council of Architectural Registration Board #52853 DOB Barcode ATOZ Consulting Engineers, PC Ilya Malyuchenko, P.E. 363 7th Avenue 3rd Floor New York, NY 10001 212.929.2491 [email protected] Consultant Contact Address Phone e-mail NYC Building Restoration Robert M. Hanna, P.E. 9011 Northern Boulevard Suite 307 Jackson Heights, NY 11372 646-522-0589 [email protected] MECHANICAL STRUCTURAL As indicated A-000 GENERAL NOTES / PLOT PLAN ELAM RESIDENCE 300 EAST 74TH STREET PENTHOUSE-F/36TH FLOOR NEW YORK, NY 10021 04/03/2015 BUILDING DEPT. GENERAL NOTES 1. SCOPE OF WORK: APPLICATION FILED FOR THE INTERIOR RENOVATION OF EXISTING PENTHOUSE F. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. 2. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE NEW YORK CITY BUILDING CODE, FIRE DEPARTMENT REGULATIONS, UTILITY COMPANY REQUIREMENTS, AND THE BEST TRADE PRACTICES. 3. BEFORE COMMENCING WORK, THE CONTRACTOR SHALL FILE ALL REQUIRED CERTIFICATES OF INSURANCE WITH THE DEPARTMENT OF BUILDINGS, OBTAIN ALL REQUIRED PERMITS, AND PAY ALL FEES REQUIRED BY GOVERNING NEW YORK CITY AGENCIES. 4. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO COMMENCING WORK, AND SHALL REPORT ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS TO THE ARCHITECT. 5. MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER CONSTRUCTION OF ANY PART OF THE WORK SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE DRAWINGS. 6. THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH REQUIREMENTS OF LOCAL AUTHORITIES AND BUILDING MANAGEMENT. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL CONDITIONS AND MATERIALS WITHIN THE PROPOSED CONSTRUCTION AREA. THE CONTRACTOR SHALL DESIGN AND INSTALL ADEQUATE SHORING AND BRACING FOR ALL STRUCTURAL OR REMOVAL TASKS. THE CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY OR DURING THE EXECUTION OF THE WORK. 8. THE CONTRACTOR SHALL LAY OUT HIS OWN WORK, AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR OTHER TRADES (PLUMBING, ELECTRICAL, ETC.). 9. PLUMBING, HVAC, AND ELECTRICAL WORK SHALL BE PERFORMED BY PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS. 10. THE CONTRACTOR SHALL DO ALL CUTTING, PATCHING, REPAIRING AS REQUIRED TO PERFORM ALL OF THE WORK INDICATED ON THE DRAWINGS, AND ALL OTHER WORK THAT MAY BE REQUIRED TO COMPLETE THE JOB. 11. ALL PIPING AND WIRING SHALL BE REMOVED TO A POINT OF CONCEALMENT AND SHALL BE PROPERLY CAPPED OR PLUGGED. 12. THE CONTRACTOR, UPON COMPLETION OF THE WORK, SHALL ARRANGE FOR DEPARTMENT OF BUILDINGS INSPECTIONS AND SIGNOFFS AS REQUIRED SMOKE/CARBON MONOXIDE DETECTION DEVICES 1. SMOKE/CARBON MONOXIDE DETECTORS OR DEVICES SHALL BE INSTALLED IN ORDINANCE WITH THE HOUSING MAINTENANCE CODE,MULTIPLE DWELLING LAW, THE NEW YORK CITY BUILDING CODE, AND THE NEW YORK CITY ELECTRICAL CODE. 2. SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS MAY BE COMBINED PROVIDING THE DEVICES COMPLY WITH THE PROVISIONS OF TITLE OF THE ADMINISTRATIVE CODE OF THE CITY OF NEW YORK AND ANY APPLICABLE RULES PROMULGATED THEREUNDER. 3. EACH SMOKE/CARBON MONOXIDE DETECTOR SHALL BE INSTALLED IN ACCORDANCE WITH SECTION BC 908.7.1 THROUGH 908.7.3. 4. EACH SMOKE/CARBON MONOXIDE DETECTOR SHALL BE INSTALLED OUTSIDE OF EACH SLEEPING ROOM IN THE IMMEDIATE VICINITY OR WITHIN 15'-0" OF THE ENTRANCE TO A SLEEPING ROOM. 5. EACH SMOKE CARBON MONOXIDE DETECTOR SHALL BE OF A TYPE THAT ALLOWS FOR READILY TESTING OF SUCH DEVICE. 6. DUPLEX UNITS SHALL HAVE A DEVICE LOCATED ON EACH LEVEL IF ONLY ONE MEANS OF EGRESS IS PROVIDED FROM EACH LEVEL. 7. CEILING MOUNTED DEVICES SHALL BE A MINIMUM DISTANCE OF 4" FROM ANY WALL. 8. WALL MOUNTED DEVICES SHALL BE A MINIMUM OF 4" TO A MAXIMUM OF 12" FROM THE CEILING. 9. EACH DWELLING UNIT SHALL BE EQUIPPED WITH AN APPROVED TYPE SMOKE/CARBON MONOXIDE DETECTOR DEVICE. 10. SUCH SMOKE/CARBON MONOXIDE DETECTOR MUST BE EITHER THE IONIZATION OR PHOTO-ELECTRIC TYPE. PLUMBING AND DRAINAGE NOTES 1. ALL PLUMBING AND GAS PIPING WORK SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF 2008 NEW YORK CITY PLUMBING CODE. 2. PLUMBING FIXTURES SHALL BE OF TYPE AND MANUFACTURE APPROVED FOR USE IN NEW YORK CITY, AND SHALL BEAR BS&A APPROVAL. 3. ALL GAS-FIRED EQUIPMENT TO BE A.G.A. OR M.E.A. APPROVED. 4. PLUMBING CONTRACTOR TO EXAMINE PROPOSED LAYOUT WITH REGARD TO EXISTING FIELD CONDITIONS, AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN ASSUMED FIELD CONDITIONS AND THOSE ENCOUNTERED DURING CONSTRUCTION. PLUMBING CONTRACTOR SHALL INFORM ARCHITECT OF ANY REVISIONS TO PLAN WHICH SHALL BE NECESSARY, BASED ON CONDITIONS UNCOVERED IN THE FIELD, IN ORDER TO INSTALL ALL FIXTURES, EQUIPMENT AND PIPING IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF THE NYC BUILDING CODE. 5. PLUMBING CONTRACTOR SHALL ARRANGE AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS. NOTE: THIS PLAN IS APPROVED ONLY FOR WORK APPROVED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS SHOWN ARE NOT TO BE RELIED UPON, OR TO BE CONSIDERED AS EITHER APPROVED OR IN ACCORDANCE WITH APPLICABLE CODES. ALL PLUMBING WORK FILED UNDER SEPARATE LAA BY LICENSED PLUMBING. PLUMBING WORK SHOWN AS REFERENCE ONLY. SITE SAFETY THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. THE CONTRACTOR HAS THE RESPONSIBILITY FOR THE SUPERINTENDENCE OF CONSTRUCTION PROCESSES. SITE CONDITIONS, OPERATIONS, EQUIPMENT, PERSONNEL, THE MAINTENANCE OF A SAFE PLACE TO WORK AND ANY SAFETY IN, ON, OR AROUND THE SITE OF WORK. LEAD NOTES THE OWNER, GENERAL CONTRACTOR, DEMOLITION SUBCONTRACTOR ARE ADVISED THAT THERE IS A POSSIBILITY OF LEAD PAINT HAVING BEEN USED IN THE EXISTING CONSTRUCTION. THE DEMOLITION PORTION OF THE JOB MUST BE PERFORMED ACCORDING TO SAFE WORK PRACTICES (OSHA). INCLUDING WORKER PROTECTION, PREVENTION OF SPREAD OF LEAD DUST AND NOTIFICATION OF THE PUBLIC AND GOV'T AGENCIES AND PROPER DISPOSAL OF CONTAMINATED REFUSE. AFTER THE DEMO IS PROPERLY FINISHED AND PROPER CLEAN UP IS PERFORMED, IT IS NO LONGER A LEAD ABATEMENT JOB. THE OWNER IS OBLIGED TO COMPLY WITH LOCAL LAW 1 OF 2004. COMPLY WITH ALL NYC LAWS. SCOPE OF WORK NOTES 1. THE SCOPE OF WORK FOR THIS PROJECT REQUIRES THE FILING OF AN ALTERATION TYPE 2 APPLICATION AT THE NEW YORK CITY BUILDING DEPARTMENT. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING A PERMIT FOR THIS WORK PRIOR TO CONSTRUCTION. 2. CONTRACTOR SHALL MAINTAIN PERMIT UNTIL ALL SIGN-OFFS ARE COMPLETE. 3. ALL CONTRACTORS SHALL BE LICENSED BY THE CITY OF NEW YORK FOR HIS/HER TRADE RESPECTIVELY. ZONING CONSTRUCTION CLASSIFICATION 1: FIREPROOF STRUCTURES CCCUPANCY CLASSIFICATION RES SCOPE OF WORK APPLICATION FILED FOR THE INTERIOR RENOVATION OF EXISTING APARTMENT #5E. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. ENERGY TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGEMENT, ALL WORK UNDER THIS APPLICATION IS IN COMPLIANCE WITH NYCECC 2011. ZONING INFO BLOCK: 1448 LOT: 3 ZONE: C1-9 R8B MAP: 8C BOROUGH: MANHATTAN ADDRESS: 300 EAST 74TH STREET PH-F NEW YORK, NY 10021 NOTE: NO CHANGE IN BULK AND HEIGHT OF THE BUILDING IS PROPOSED IN THIS APPLICATION NOTE: NO CHANGE TO USE, EGRESS OR OCCUPANCY IS PROPOSED IN THIS APPLICATION TENENT PROTECTION NOTES 1. GENERAL: ALL WORK TO BE COMPLETED IN ACCORDANCE WITH THE NEW YORK BUILDING CODE, ARTICLE 19, AND REGULATIONS OF ALL OTHER AGENCIES HAVING JURISDICTION. THE BUILDING CONTAINS UNITS THAT WILL BE OCCUPIED DURING CONSTRUCTION. 2. MEANS OF EGRESS: ALL EXISTING MEANS OF EGRESS FOR TENANTS OF THE BUILDING TO BE MAINTAINED CLEAR AND FREE OF ALL OBSTRUCTION, SUCH AS BUILDING MATERIALS, TOOLS, ETC. 3. FIRE SAFETY: A) ALL BUILDING MATERIALS, WHICH ARE STORED AT THE SITE OR ANY AREA OF THE BUILDING, ARE TO BE STORED IN A LOCKED AREA. ACCESS TO THE AREAS TO BE CONTROLLED BY THE OWNER, OR THE GENERAL CONTRACTOR. B) ALL MATERIALS TO BE STORED IN AN ORDERLY FASHION. C) ALL FLAMMABLE MATERIALS TO BE KEPT AND TIGHTLY SEALED IN THEIR RESPECTIVE MANUFACTURER'S CONTAINERS. SUCH MATERIALS ARE TO BE KEPT FROM SOURCES OF HEAT. D) ALL FLAMMABLE MATERIALS TO BE USED AND STORED IN AN ADEQUATELY VENTILATED SPACE. E) ALL ELECTRICAL POWER TO BE SHUT-OFF WHERE THERE ARE EXPOSED CONDUIT. F) ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA TO BE SHUT OFF AFTER WORKING HOURS. G) CONTRACTOR. AT ALL TIMES, SHALL ENSURE THERE IS NO NATURAL GAS LEAKAGE IN THE BUILDINGS, OR ANY FLAMMABLE GAS TO BE USED DURING CONSTRUCTION. 4. HEALTH REQUIREMENTS: A). DUST CONTROL: 1) DEBRIS, DIRT, AND DUST TO BE KEPT TO A MINIMUM AND CONFINED TO THE IMMEDIATE CONSTRUCTION AREA, AND SHALL NOT CREATE DUST, DIRT OR OTHER SUCH INCONVENIENCES TO OTHER APARTMENT UNITS WITHIN THE BUILDING. 2) CONTRACTOR SHALL ISOLATE CONSTRUCTION AREA FROM OCCUPIED BUILDING AREA BY MEANS OF TEMPORARY PARTITIONS OR HEAVY WEIGHT DROPCLOTH. 3) DEBRIS, DIRT, AND DUST SHALL BE CLEANED-UP AND CLEARED FROM THE BUILDING SITE PERIODICALLY TO AVOID EXCESSIVE ACCUMULATION. B). DISPOSAL OF CONSTRUCTION DEBRIS: ALL DEBRIS AND PRODUCTS OF DEMOLITION NOT DESIGNATED FOR REFUSE SHALL BE REMOVED FROM THE PREMISES AND LEGALLY DISPOSED OF. THE SITE SHALL BE LEFT BROOM CLEAN AT THE END OF EVERY WORKING DAY. C). PEST CONTROL: SHALL CONFORM TO ARTICLE 13 OF THE NYC HOUSING MAINTENANCE CODE WITH REGARDS TO: 1) RODENT AND INSECT ERADICATION; MANDATORY EXTERMINATION ` 2) ELIMINATION OF HARBORAGES D). MAINTENANCE OF SANITARY FACILITIES: SHALL CONFORM TO ARTICLE 14 OF THE NYC HOUSING MAINTENANCE CODE. E). NOISE CONTROL: ALL WORK SHALL CONFORM TO LOCAL LAW 113/2005. F). LEAD: ALL WORK SHALL CONFORM TO LOCAL LAW 1/2004 WITH REGARDS TO THE HANDLING OF LEAD. G). ASBESTOS: ALL WORK SHALL CONFORM TO THE NYS DEP ASBESTOS CONTROL PROGRAM §1-01 WITH REGARDS TO THE HANDLING OF ASBESTOS. 5. STRUCTURAL SAFETY: NO STRUCTURAL WORK SHALL BE DONE THAT MAY ENDANGER THE OCCUPANTS. 6. NOISE RESTRICTIONS 1) CONSTRUCTION OPERATION WILL BE CONFINED TO NORMAL WORKING HOURS: 8:00 AM TO 5:00 PM, MONDAY THRU FRIDAY, EXCEPT LEGAL HOLIDAYS. AFTER HOURS AND WEEKEND WORK BE SPECIAL PERMIT ONLY. 2) CONTRACTOR MUST OBTAIN WRITTEN PERMISSION FROM ALL AFFECTED PARTIES TO WORK OUTSIDE OF THE REGULAR HOURS STATED ABOVE. ELAM RESIDENCE 300 EAST 74TH STREET PH-F, NEW YORK, NY 10021 ADA COMPLIANCE - LOCAL LAW 58/87 ADA COMPLIANCE- LOCAL LAW 58/87 NOTES 1. ALL WORK TO COMPLY WITH LOCAL LAW 58/87. WORK IN BOTH THE KITCHEN AND THE BATHROOMS TO COMPLY WITH NYC DEPARTMENT OF BUILDINGS POLICY AND PROCEDURES NOTICES: PPN #15/88, PNN #1/92, PPN #3/92 2. NEW DOORWAYS AND FRAMED OPENINGS MUST COMPLY WITH ADA / NYC LOCAL LAW 58 OF 1987 CLEARANCE REQUIREMENTS. NEW DOOR HARDWARE AND THRESHOLDS TO BE ADA-COMPLIANT. 3. NEW ELECTRICAL OUTLETS, TELEPHONE OUTLETS, ETC, TO BE INSTALLED IN COMPLIANCE WITH AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) A117.1 - 1986. NO OULET TO MOUNTED LESS THEN 15" AFF, SWITCHES TO BE MOUNTED NO HIGHER THAN 48" TO TOP OF BOX. 4. REPLACEMENT OF PLUMBING FIXTURES ON EXISTING ROUGHING DOES NOT MANDATE COMPLIANCE WITH HANDICAP ACCESSIBLITY REQUIREMENTS PER LOCAL LAW 58/87. 5. RELOCATION OR NEW FIXTURES INSTALLED TO COMPLY WITH LL58/87 PLUMBING RISER DIAGRAM - NOT TO SCALE ASBESTOS NOTES IN THE EVENT OF ASBESTOS OR OTHER TOXIC SUBSTANCE EXPOSURE OR THE SUBSTANTIAL RISK THEREOF, CLIENT WILL HAVE THE DUTY TO INFORM ARCHITECT OF SUCH RISKS KNOWN OR REASONABLY KNOWABLE TO CLIENT. IF ASBESTOS, OR ANY OTHER TOXIC SUBSTANCE, OR RISK TO EXPOSURE THERETO IS DISCOVERED BY THE ARCHITECT DURING WORK ON THE PROJECT, ARCHITECT SHALL, IN HIS SOLE DISCRETION, HAVE THE RIGHT TO SUSPEND WORK ON THE PROJECT. CLIENT SHALL HAVE THE DUTY PROMPTLY TO RETAIN A QUALIFIED EXPERT SAFELY TO REMOVE OR SUPERVISE THE REMOVAL OF SUCH ASBESTOS OR OTHER TOXIC SUBSTANCE. CLIENT SHALL INDEMNIFY AND HOLD ARCHITECT, HIS AFFILIATES AND SUBCONTRACTORS, AND THEIR OFFICERS, AGENTS AND EMPLOYEES HARMLESS FROM ANY AND ALL LIABILITY ON THE PART OF OR DAMAGE TO SUCH ENTITIES OR PERSONS, INCLUDING THE COST OF LEGAL FEES AND EXPENSES, AS SUCH FEES AND EXPENSES ARE INCURED, WHICH MAY RESULT FROM ASBESTOS OR OTHER TOXIC SUBSTANCE EXPOSURE ON THE PROJECT. INTERIOR FINISH NOTES 1. THE CONTRACTOR SHALL INSPECT ALL SURFACES AND PROVIDE ALL PREPARATORY WORK NECESSARY TO ACHIEVE NEW FINISHES. 2. ALL AREAS SHALL BE FINISHED AS PER FINISH PLANS & RELATED NOTES ON CONSTRUCTION PLANS. 3. ON WALL SURFACES SCHEDULED TO RECEIVE PAINT, ALL PAINT SHALL BE APPLIED IN ACCORDANCE WITH THE MFR'S SPECIFICATIONS OR AS INDICATED. 4. ALL PAINTED CLGS. TO MATCH ADJACENT PAINT FINISH OR NEW PAINT FINISH SHALL BE FLAT LATEX U.O.N. 5. ONLY LOW VOC (VOLITILE ORGANIC COMPOUND) PAINT AND FLOOR FINISH MATERIALS WILL BE PERMITTED FOR USE. PROGRESS INSPECTIONS: THE FOLLOWING SHALL BE SUBJECT TO PROGRESS INSPECTIONS 1. ENERGY CODE COMPLIANCE INSPECTIONS (BC 109.3.5) 2. FINAL INSPECTION (1RCNY-101-10) SPECIAL INSPECTIONS: THE FOLLOWING SHALL BE SUBJECT TO SPECIAL INSPECTIONS 1. STRUCTURAL STEEL - WELDING (BC 1704.3.1) 2. STRUCTURAL STEEL - HIGH STRENGTH BOLTING (BC 1704.3.3) 3. STRUCTURAL STABILITY - EXISTING BUILDINGS (BC 1704.20.1) 4. FIRE RESISTANT PENETRATIONS AND JOINTS (BC 1704.27) SHEET INDEX Sheet # Sheet Name A-000 GENERAL NOTES / PLOT PLAN A-100 REMOVAL PLANS A-101 CONSTRUCTION PLANS A-102 ROOF PLANS A-103 REFLECTED CEILING PLANS A-104 FLOOR FINISHES PLANS A-201 KITCHEN ENLARGED PLANS A-202 KITCHEN ELEVATIONS A-203 BATHROOM ENLARGED PLANS & ELEVATIONS A-204 BEDROOM ENLARGED PLANS & ELEVATIONS A-205 MAIN FLOOR ENLARGED PLANS & ELEVATIONS A-206 GREENHOUSE ENLARGED PLAN & ELEVATIONS A-301 GREENHOUSE FRAMING PLAN A-302 GREENHOUSE SECTIONS A-303 STAIRWELL PLANS & SECTIONS A-501 STAIR DETAILS I A-502 STAIR DETAILS II A-503 GREENHOUSE DETAILS A-504 ROOF DETAILS A-505 FLOOR DETAILS A-506 CASEWORK DETAILS A-507 CEILING DETAILS A-600 FIXTURE, APPLIANCE, & DOOR SCHEDULES A-601 FINISH SCHEDULES M-001 MECHANICAL SYMBOLS & NOTES M-100 MECHANICAL PLANS & SCHEDULES M-200 MECHANICAL DETAILS & SECTIONS M-300 MECHANICAL SPECIFICATIONS E-101 POWER PLANS P-101 PLUMBING PLANS GAS RISER DIAGRAM - NOT TO SCALE PLOT PLAN - NOT TO SCALE ADA COMPLIANCE DIAGRAMS No. Description Date N

Upload: sean-roper

Post on 15-Jul-2015

197 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Elam Pricing Full Set 4.3.15

SD

1 PARTITION TYPE

GRAPHIC SYMBOLS

WALL MOUNTED SMOKE DETECTOR

EXHAUST VENT

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE REMOVED

NEW CONSTRUCTION

EX

G 6

" V

EN

T. S

TA

CK

EX

G 4

" S

OIL

ST

AC

K

3"2"

RELOCATEW/C

2"

RELOCATELAV

1 1/

2"

BATH 2 POWDER ROOM

4"CO.

4"CO.

3" 2"

RELOCATEW/C

2"

RELOCATELAV

1 1/2"

3"

1 1/

2"

RELOCATESHOWER

MASTER BATH

3"1-1/2"

RELOCATEW/C

2"

RELOCATELAV

1 1/

2"

4"CO.

3"

1 1/

2"

RELOCATESHOWER

1-1/2"

REMOVELAV

1 1/

2"

REMOVEHOT TUB

2"

LAUNDRY

2"

FLOOR DRAIN

GREENHOUSE

EX

G 6

" V

EN

T. S

TA

CK

EX

G 4

" S

OIL

ST

AC

K

PH-F Upper Level

PH-F 36th Flr Main Level

CO.1-1/2"

1 1/

2" RELOCATESINK

KITCHEN

EXIST. HOUSE TRAP

RELOCATEDISHWASHER

CO.1-1/2"

1 1/

2" NEWSINK

GREENHOUSE

Roof

EAST 73RD STREET

37 STORY BUILDING#300BLOCK: 1448LOT: 3OCCUPANCY CLASS: RESCONSTRUCTION CLASS: 1

AREA OFWORK ON36TH FLOOR

ADJACENT 14 STORYBUILDING

ADJACENT 6 STORYBUILDING

100

102.

17

100100

102.

17

153.2551.08

100

51.08

100 25

25

25

EAST 74TH STREET

2ND

AV

EN

UE

NEIGHBORING 2 STORYBUILDING

M

GASMETER

CELLAR

3/4"

RELOCATEGAS RANGE

EXISTINGGAS RISER

APT. 5E

KITCHEN

EXISTINGGAS SHUT-OFFVALVE

36TH FLOOR

Push Side

42 minY

54 min

X24 preferred60 min18 min,

Pull Side

48 min

X Push Side

Pull Side

NOTE: All doors in alcoves shall comply with the clearances for front approaches.

12"

(FIG. 25)(FIG. 25)

Clearance of optional enclosure.

NOTE: Dashed line indicates dimensional

8 min Knee

6 max Toe

17 min Lavatory Depth

9 min

27 m

in

29 m

in

49 m

ax

19 max17 min

clear floor space

30 m

in

48 min

6 max

38 m

in

32 m

ax

24 min

38 m

in

32 m

ax

foot

areacontrol

24 min

6 m

ax38 m

in

48 min

back

6 max

seat

head

back wall side wall

38 m

in

38 m

in

12 min 12 min

32 m

ax

toilet paper

19 m

in

12 18 min

36 max

32 m

ax

clear floor space

18

lav.

min

36 min

56 m

in

48 min

min

clear floor space

lav.

1816-18

36 min

66 m

in

48 min

16-18

Clearance

Clearance

spacefloor

30 m

inclear

60 min

back

foot

head

18 m

in

B. Hinge Side Approaches - SwingingDoors

A. Front Approaches - Swinging Doors

NOTE: y = 48" minimum ifdoor has both a latchand closer.

NOTE: x = 36" minimum if y= 60"; x = 42" minimumif y = 54".

NOTE: x = 12" if doorhas both a closerand latch.

MANEUVERING CLEARANCES AT DOORSCLEAR FLOOR SPACE

AT BATHTUBREINFORCED AREAS FOR GRABS AT BATHTUB

CLEAR FLOOR SPACE AT WATER CLOSETREINFORCED AREAS FOR GRAB BARS AT WATER CLOSET CLEAR FLOOR SPACE AND CLEARANCES AT LAVATORIES

.

.

. .

Y.

.

. .

.

...

..

.

.

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

As indicated

A-000

GENERAL NOTES / PLOT PLAN

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

BUILDING DEPT. GENERAL NOTES1. SCOPE OF WORK: APPLICATION FILED FOR THE INTERIOR RENOVATION OF EXISTING PENTHOUSE F. NOCHANGE IN USE, OCCUPANCY, OR EGRESS.

2. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE NEW YORK CITY BUILDING CODE, FIREDEPARTMENT REGULATIONS, UTILITY COMPANY REQUIREMENTS, AND THE BEST TRADE PRACTICES.

3. BEFORE COMMENCING WORK, THE CONTRACTOR SHALL FILE ALL REQUIRED CERTIFICATES OFINSURANCE WITH THE DEPARTMENT OF BUILDINGS, OBTAIN ALL REQUIRED PERMITS, AND PAY ALL FEESREQUIRED BY GOVERNING NEW YORK CITY AGENCIES.

4. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO COMMENCING WORK,AND SHALL REPORT ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS TO THEARCHITECT.

5. MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER CONSTRUCTION OFANY PART OF THE WORK SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE DRAWINGS.

6. THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH REQUIREMENTS OF LOCALAUTHORITIES AND BUILDING MANAGEMENT.

7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL CONDITIONS AND MATERIALSWITHIN THE PROPOSED CONSTRUCTION AREA. THE CONTRACTOR SHALL DESIGN AND INSTALL ADEQUATESHORING AND BRACING FOR ALL STRUCTURAL OR REMOVAL TASKS. THE CONTRACTOR SHALL HAVE SOLERESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY OR DURING THE EXECUTION OF THE WORK.

8. THE CONTRACTOR SHALL LAY OUT HIS OWN WORK, AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOROTHER TRADES (PLUMBING, ELECTRICAL, ETC.).

9. PLUMBING, HVAC, AND ELECTRICAL WORK SHALL BE PERFORMED BY PERSONS LICENSED IN THEIRTRADES, WHO SHALL ARRANGE FOR AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS.

10. THE CONTRACTOR SHALL DO ALL CUTTING, PATCHING, REPAIRING AS REQUIRED TO PERFORM ALL OFTHE WORK INDICATED ON THE DRAWINGS, AND ALL OTHER WORK THAT MAY BE REQUIRED TO COMPLETETHE JOB.

11. ALL PIPING AND WIRING SHALL BE REMOVED TO A POINT OF CONCEALMENT AND SHALL BE PROPERLYCAPPED OR PLUGGED.

12. THE CONTRACTOR, UPON COMPLETION OF THE WORK, SHALL ARRANGE FOR DEPARTMENT OFBUILDINGS INSPECTIONS AND SIGNOFFS AS REQUIRED

SMOKE/CARBON MONOXIDE DETECTIONDEVICES1. SMOKE/CARBON MONOXIDE DETECTORS OR DEVICES SHALL BE INSTALLED IN ORDINANCE WITH THEHOUSING MAINTENANCE CODE,MULTIPLE DWELLING LAW, THE NEW YORK CITY BUILDING CODE, AND THENEW YORK CITY ELECTRICAL CODE.

2. SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS MAY BE COMBINED PROVIDING THE DEVICESCOMPLY WITH THE PROVISIONS OF TITLE OF THE ADMINISTRATIVE CODE OF THE CITY OF NEW YORK ANDANY APPLICABLE RULES PROMULGATED THEREUNDER.

3. EACH SMOKE/CARBON MONOXIDE DETECTOR SHALL BE INSTALLED IN ACCORDANCE WITH SECTION BC908.7.1 THROUGH 908.7.3.

4. EACH SMOKE/CARBON MONOXIDE DETECTOR SHALL BE INSTALLED OUTSIDE OF EACH SLEEPING ROOM INTHE IMMEDIATE VICINITY OR WITHIN 15'-0" OF THE ENTRANCE TO A SLEEPING ROOM.

5. EACH SMOKE CARBON MONOXIDE DETECTOR SHALL BE OF A TYPE THAT ALLOWS FOR READILY TESTINGOF SUCH DEVICE.

6. DUPLEX UNITS SHALL HAVE A DEVICE LOCATED ON EACH LEVEL IF ONLY ONE MEANS OF EGRESS ISPROVIDED FROM EACH LEVEL.

7. CEILING MOUNTED DEVICES SHALL BE A MINIMUM DISTANCE OF 4" FROM ANY WALL.

8. WALL MOUNTED DEVICES SHALL BE A MINIMUM OF 4" TO A MAXIMUM OF 12" FROM THE CEILING.

9. EACH DWELLING UNIT SHALL BE EQUIPPED WITH AN APPROVED TYPE SMOKE/CARBON MONOXIDEDETECTOR DEVICE.

10. SUCH SMOKE/CARBON MONOXIDE DETECTOR MUST BE EITHER THE IONIZATION OR PHOTO-ELECTRICTYPE.

PLUMBING AND DRAINAGE NOTES1. ALL PLUMBING AND GAS PIPING WORK SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THEREQUIREMENTS OF 2008 NEW YORK CITY PLUMBING CODE.

2. PLUMBING FIXTURES SHALL BE OF TYPE AND MANUFACTURE APPROVED FOR USE IN NEW YORK CITY,AND SHALL BEAR BS&A APPROVAL.

3. ALL GAS-FIRED EQUIPMENT TO BE A.G.A. OR M.E.A. APPROVED.

4. PLUMBING CONTRACTOR TO EXAMINE PROPOSED LAYOUT WITH REGARD TO EXISTING FIELDCONDITIONS, AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN ASSUMED FIELDCONDITIONS AND THOSE ENCOUNTERED DURING CONSTRUCTION. PLUMBING CONTRACTOR SHALLINFORM ARCHITECT OF ANY REVISIONS TO PLAN WHICH SHALL BE NECESSARY, BASED ON CONDITIONSUNCOVERED IN THE FIELD, IN ORDER TO INSTALL ALL FIXTURES, EQUIPMENT AND PIPING IN STRICTACCORDANCE WITH THE REQUIREMENTS OF THE NYC BUILDING CODE.

5. PLUMBING CONTRACTOR SHALL ARRANGE AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS.

NOTE: THIS PLAN IS APPROVED ONLY FOR WORK APPROVED ON THE APPLICATION SPECIFICATIONSHEET. ALL OTHER MATTERS SHOWN ARE NOT TO BE RELIED UPON, OR TO BE CONSIDERED AS EITHERAPPROVED OR IN ACCORDANCE WITH APPLICABLE CODES.

ALL PLUMBING WORK FILED UNDER SEPARATE LAA BY LICENSED PLUMBING. PLUMBING WORK SHOWNAS REFERENCE ONLY.

SITE SAFETYTHIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. THECONTRACTOR HAS THE RESPONSIBILITY FOR THE SUPERINTENDENCE OF CONSTRUCTION PROCESSES.SITE CONDITIONS, OPERATIONS, EQUIPMENT, PERSONNEL, THE MAINTENANCE OF A SAFE PLACE TOWORK AND ANY SAFETY IN, ON, OR AROUND THE SITE OF WORK.

LEAD NOTESTHE OWNER, GENERAL CONTRACTOR, DEMOLITION SUBCONTRACTOR ARE ADVISED THAT THERE IS APOSSIBILITY OF LEAD PAINT HAVING BEEN USED IN THE EXISTING CONSTRUCTION.THE DEMOLITION PORTION OF THE JOB MUST BE PERFORMED ACCORDING TO SAFE WORK PRACTICES(OSHA). INCLUDING WORKER PROTECTION, PREVENTION OF SPREAD OF LEAD DUST AND NOTIFICATION OFTHE PUBLIC AND GOV'T AGENCIES AND PROPER DISPOSAL OF CONTAMINATED REFUSE. AFTER THE DEMO ISPROPERLY FINISHED AND PROPER CLEAN UP IS PERFORMED, IT IS NO LONGER A LEAD ABATEMENT JOB.THE OWNER IS OBLIGED TO COMPLY WITH LOCAL LAW 1 OF 2004. COMPLY WITH ALL NYC LAWS.

SCOPE OF WORK NOTES1. THE SCOPE OF WORK FOR THIS PROJECT REQUIRES THE FILING OF AN ALTERATION TYPE 2 APPLICATION AT THENEW YORK CITY BUILDING DEPARTMENT. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING A PERMIT FOR THISWORK PRIOR TO CONSTRUCTION.

2. CONTRACTOR SHALL MAINTAIN PERMIT UNTIL ALL SIGN-OFFS ARE COMPLETE.

3. ALL CONTRACTORS SHALL BE LICENSED BY THE CITY OF NEW YORK FOR HIS/HER TRADE RESPECTIVELY.

ZONINGCONSTRUCTION CLASSIFICATION

1: FIREPROOF STRUCTURES

CCCUPANCY CLASSIFICATION

RES

SCOPE OF WORK

APPLICATION FILED FOR THE INTERIOR RENOVATION OF EXISTINGAPARTMENT #5E. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.

ENERGY

TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONALJUDGEMENT, ALL WORK UNDER THIS APPLICATION IS INCOMPLIANCE WITH NYCECC 2011.

ZONING INFO

BLOCK: 1448LOT: 3ZONE: C1-9 R8BMAP: 8CBOROUGH: MANHATTANADDRESS: 300 EAST 74TH STREET PH-F

NEW YORK, NY 10021

NOTE: NO CHANGE IN BULK AND HEIGHT OF THEBUILDING IS PROPOSED IN THIS APPLICATION

NOTE: NO CHANGE TO USE, EGRESS OROCCUPANCY IS PROPOSED IN THIS APPLICATION

TENENT PROTECTION NOTES1. GENERAL:ALL WORK TO BE COMPLETED IN ACCORDANCE WITH THE NEW YORK BUILDING CODE, ARTICLE 19, ANDREGULATIONS OF ALL OTHER AGENCIES HAVING JURISDICTION. THE BUILDING CONTAINS UNITS THAT WILL BEOCCUPIED DURING CONSTRUCTION.

2. MEANS OF EGRESS:ALL EXISTING MEANS OF EGRESS FOR TENANTS OF THE BUILDING TO BE MAINTAINED CLEAR AND FREE OF ALLOBSTRUCTION, SUCH AS BUILDING MATERIALS, TOOLS, ETC.

3. FIRE SAFETY:A) ALL BUILDING MATERIALS, WHICH ARE STORED AT THE SITE OR ANY AREA OF THE BUILDING, ARE TO BESTORED IN A LOCKED AREA. ACCESS TO THE AREAS TO BE CONTROLLED BY THE OWNER, OR THE GENERALCONTRACTOR.B) ALL MATERIALS TO BE STORED IN AN ORDERLY FASHION.C) ALL FLAMMABLE MATERIALS TO BE KEPT AND TIGHTLY SEALED IN THEIR RESPECTIVE MANUFACTURER'SCONTAINERS. SUCH MATERIALS ARE TO BE KEPT FROM SOURCES OF HEAT.D) ALL FLAMMABLE MATERIALS TO BE USED AND STORED IN AN ADEQUATELY VENTILATED SPACE.E) ALL ELECTRICAL POWER TO BE SHUT-OFF WHERE THERE ARE EXPOSED CONDUIT.F) ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA TO BE SHUT OFF AFTER WORKING HOURS.G) CONTRACTOR. AT ALL TIMES, SHALL ENSURE THERE IS NO NATURAL GAS LEAKAGE IN THE BUILDINGS, OR ANYFLAMMABLE GAS TO BE USED DURING CONSTRUCTION.

4. HEALTH REQUIREMENTS:A). DUST CONTROL: 1) DEBRIS, DIRT, AND DUST TO BE KEPT TO A MINIMUM AND CONFINED TO THE IMMEDIATE CONSTRUCTION AREA,AND SHALL NOT CREATE DUST, DIRT OR OTHER SUCH INCONVENIENCES TO OTHER APARTMENT UNITS WITHINTHE BUILDING. 2) CONTRACTOR SHALL ISOLATE CONSTRUCTION AREA FROM OCCUPIED BUILDING AREA BY MEANS OFTEMPORARY PARTITIONS OR HEAVY WEIGHT DROPCLOTH. 3) DEBRIS, DIRT, AND DUST SHALL BE CLEANED-UP AND CLEARED FROM THE BUILDING SITE PERIODICALLY TOAVOID EXCESSIVE ACCUMULATION.B). DISPOSAL OF CONSTRUCTION DEBRIS: ALL DEBRIS AND PRODUCTS OF DEMOLITION NOT DESIGNATED FORREFUSE SHALL BE REMOVED FROM THE PREMISES AND LEGALLY DISPOSED OF. THE SITE SHALL BE LEFT BROOMCLEAN AT THE END OF EVERY WORKING DAY.C). PEST CONTROL: SHALL CONFORM TO ARTICLE 13 OF THE NYC HOUSING MAINTENANCE CODE WITH REGARDSTO: 1) RODENT AND INSECT ERADICATION; MANDATORY EXTERMINATION` 2) ELIMINATION OF HARBORAGESD). MAINTENANCE OF SANITARY FACILITIES: SHALL CONFORM TO ARTICLE 14 OF THE NYC HOUSING MAINTENANCECODE.E). NOISE CONTROL: ALL WORK SHALL CONFORM TO LOCAL LAW 113/2005.F). LEAD: ALL WORK SHALL CONFORM TO LOCAL LAW 1/2004 WITH REGARDS TO THE HANDLING OF LEAD.G). ASBESTOS: ALL WORK SHALL CONFORM TO THE NYS DEP ASBESTOS CONTROL PROGRAM §1-01 WITHREGARDS TO THE HANDLING OF ASBESTOS.

5. STRUCTURAL SAFETY:NO STRUCTURAL WORK SHALL BE DONE THAT MAY ENDANGER THE OCCUPANTS.

6. NOISE RESTRICTIONS1) CONSTRUCTION OPERATION WILL BE CONFINED TO NORMAL WORKING HOURS: 8:00 AM TO 5:00 PM, MONDAY THRUFRIDAY, EXCEPT LEGAL HOLIDAYS. AFTER HOURS AND WEEKEND WORK BE SPECIAL PERMIT ONLY.2) CONTRACTOR MUST OBTAIN WRITTEN PERMISSION FROM ALL AFFECTED PARTIES TO WORK OUTSIDE OF THEREGULAR HOURS STATED ABOVE.

ELAM RESIDENCE300 EAST 74TH STREET PH-F, NEW YORK, NY 10021

ADA COMPLIANCE - LOCAL LAW 58/87ADA COMPLIANCE- LOCAL LAW 58/87 NOTES

1. ALL WORK TO COMPLY WITH LOCAL LAW 58/87. WORK IN BOTH THE KITCHEN AND THE BATHROOMS TO COMPLYWITH NYC DEPARTMENT OF BUILDINGS POLICY AND PROCEDURES NOTICES: PPN #15/88, PNN #1/92, PPN #3/92

2. NEW DOORWAYS AND FRAMED OPENINGS MUST COMPLY WITH ADA / NYC LOCAL LAW 58 OF 1987 CLEARANCEREQUIREMENTS. NEW DOOR HARDWARE AND THRESHOLDS TO BE ADA-COMPLIANT.

3. NEW ELECTRICAL OUTLETS, TELEPHONE OUTLETS, ETC, TO BE INSTALLED IN COMPLIANCE WITH AMERICANNATIONAL STANDARDS INSTITUTE (ANSI) A117.1 - 1986. NO OULET TO MOUNTED LESS THEN 15" AFF, SWITCHES TOBE MOUNTED NO HIGHER THAN 48" TO TOP OF BOX.

4. REPLACEMENT OF PLUMBING FIXTURES ON EXISTING ROUGHING DOES NOT MANDATE COMPLIANCE WITHHANDICAP ACCESSIBLITY REQUIREMENTS PER LOCAL LAW 58/87.

5. RELOCATION OR NEW FIXTURES INSTALLED TO COMPLY WITH LL58/87

PLUMBING RISER DIAGRAM - NOT TO SCALE

ASBESTOS NOTESIN THE EVENT OF ASBESTOS OR OTHER TOXIC SUBSTANCE EXPOSURE OR THE SUBSTANTIAL RISKTHEREOF, CLIENT WILL HAVE THE DUTY TO INFORM ARCHITECT OF SUCH RISKS KNOWN OR REASONABLYKNOWABLE TO CLIENT. IF ASBESTOS, OR ANY OTHER TOXIC SUBSTANCE, OR RISK TO EXPOSURE THERETOIS DISCOVERED BY THE ARCHITECT DURING WORK ON THE PROJECT, ARCHITECT SHALL, IN HIS SOLEDISCRETION, HAVE THE RIGHT TO SUSPEND WORK ON THE PROJECT. CLIENT SHALL HAVE THE DUTYPROMPTLY TO RETAIN A QUALIFIED EXPERT SAFELY TO REMOVE OR SUPERVISE THE REMOVAL OF SUCHASBESTOS OR OTHER TOXIC SUBSTANCE. CLIENT SHALL INDEMNIFY AND HOLD ARCHITECT, HIS AFFILIATESAND SUBCONTRACTORS, AND THEIR OFFICERS, AGENTS AND EMPLOYEES HARMLESS FROM ANY AND ALLLIABILITY ON THE PART OF OR DAMAGE TO SUCH ENTITIES OR PERSONS, INCLUDING THE COST OF LEGALFEES AND EXPENSES, AS SUCH FEES AND EXPENSES ARE INCURED, WHICH MAY RESULT FROM ASBESTOSOR OTHER TOXIC SUBSTANCE EXPOSURE ON THE PROJECT.

INTERIOR FINISH NOTES1. THE CONTRACTOR SHALL INSPECT ALL SURFACES AND PROVIDE ALL PREPARATORY WORK NECESSARY TO ACHIEVENEW FINISHES.

2. ALL AREAS SHALL BE FINISHED AS PER FINISH PLANS & RELATED NOTES ON CONSTRUCTION PLANS.

3. ON WALL SURFACES SCHEDULED TO RECEIVE PAINT, ALL PAINT SHALL BE APPLIED IN ACCORDANCE WITH THE MFR'SSPECIFICATIONS OR AS INDICATED.

4. ALL PAINTED CLGS. TO MATCH ADJACENT PAINT FINISH OR NEW PAINT FINISH SHALL BE FLAT LATEX U.O.N.

5. ONLY LOW VOC (VOLITILE ORGANIC COMPOUND) PAINT AND FLOOR FINISH MATERIALS WILL BE PERMITTED FOR USE.

PROGRESS INSPECTIONS:THE FOLLOWING SHALL BE SUBJECT TO PROGRESS INSPECTIONS

1. ENERGY CODE COMPLIANCE INSPECTIONS (BC 109.3.5) 2. FINAL INSPECTION (1RCNY-101-10)

SPECIAL INSPECTIONS:THE FOLLOWING SHALL BE SUBJECT TO SPECIAL INSPECTIONS

1. STRUCTURAL STEEL - WELDING (BC 1704.3.1) 2. STRUCTURAL STEEL - HIGH STRENGTH BOLTING (BC 1704.3.3) 3. STRUCTURAL STABILITY - EXISTING BUILDINGS (BC 1704.20.1) 4. FIRE RESISTANT PENETRATIONS AND JOINTS (BC 1704.27)

SHEET INDEXSheet # Sheet Name

A-000 GENERAL NOTES / PLOT PLANA-100 REMOVAL PLANSA-101 CONSTRUCTION PLANSA-102 ROOF PLANSA-103 REFLECTED CEILING PLANSA-104 FLOOR FINISHES PLANSA-201 KITCHEN ENLARGED PLANSA-202 KITCHEN ELEVATIONSA-203 BATHROOM ENLARGED PLANS &

ELEVATIONSA-204 BEDROOM ENLARGED PLANS &

ELEVATIONSA-205 MAIN FLOOR ENLARGED PLANS &

ELEVATIONSA-206 GREENHOUSE ENLARGED PLAN &

ELEVATIONSA-301 GREENHOUSE FRAMING PLANA-302 GREENHOUSE SECTIONSA-303 STAIRWELL PLANS & SECTIONSA-501 STAIR DETAILS IA-502 STAIR DETAILS IIA-503 GREENHOUSE DETAILSA-504 ROOF DETAILSA-505 FLOOR DETAILSA-506 CASEWORK DETAILSA-507 CEILING DETAILSA-600 FIXTURE, APPLIANCE, & DOOR

SCHEDULESA-601 FINISH SCHEDULESM-001 MECHANICAL SYMBOLS & NOTESM-100 MECHANICAL PLANS & SCHEDULESM-200 MECHANICAL DETAILS & SECTIONSM-300 MECHANICAL SPECIFICATIONSE-101 POWER PLANSP-101 PLUMBING PLANS

GAS RISER DIAGRAM - NOT TO SCALE

PLOT PLAN - NOT TO SCALE

ADA COMPLIANCE DIAGRAMS

No. Description Date

N

Page 2: Elam Pricing Full Set 4.3.15

I. THE CONTRACTOR SHALL PROVIDE THE OWNER WITH THE NAMES AND PHONE NUMBERS OF ALLSUBCONTRACTORS USED DURING THE DEMOLITION (INCLUDING TRASH REMOVAL CONTRACTOR), THEDATES OF THE CONSTRUCTION IN THE TENANT PREMISES, AND COPIES OF ALL REQUIRED INSURANCECERTIFICATES, PRIOR TO THE COMMENCEMENT OF ANY WORK.

II. THE CONTRACTOR SHALL PROVIDE THE OWNER WITH A COPY OF ALL PERMITS BEFORECOMMENCEMENT OF RELEVANT WORK AS WELL AS DISPLAYING ALL PERMITS ON SITE.

III. THE CONTRACTOR SHALL CONSTRUCT DUST TIGHT PARTITIONS PRIOR TO THE COMMENCEMENT OFDEMOLITION AND ARE TO REMAIN IN PLACE UNTIL ALL WORK HAS BEEN COMPLETED AND WRITTENAPPROVAL HAS BEEN RECEIVED FROM THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FORANY AND ALL REPAIRS TO THE SURFACES MARKED OR DAMAGED BY THE PARTITION INSTALLATIONAND SUBSEQUENT REMOVAL, ALL SURFACES ARE TO BE RESTORED TO THEIR ORIGINAL CONDITION.

IV. GENERAL CONTRACTOR TO COOR. W/ OWNER FOR THE HOURS THAT THE DEMO WORK, INCLUDINGDEMOLITION REMOVAL CAN BE DONE. EXCEPTIONS WILL BE MADE ONLY WITH PRIOR APPROVAL FORMTHE LANDLORD.

V. IN THE EVENT THE CONTRACTOR FAILS TO PERFORM THE ABOVE SPECIFIED WORK DEEMEDNECESSARY BY THE OWNER, THE OWNER SHALL COMPLETE SUCH WORK AT CONTRACTOR'S /TENANT'S EXPENSE.

VI. DUST PROTECTION SHALL BE PROVIDED TO THE SPACES ADJACENT TO WORK BEING PERFORMED.CONTRACTOR REMAINS LIABLE FOR DUST AND DIRT INTRUSION INTO ADJOINING SPACE. ALL DUSTPROTECTION WORK TO BE COORDINATE WITH THE OWNER.

VIII. NO FLAMMABLE LIQUIDS OR MATERIALS SHALL BE STORED AT SITE JOB.

IX. AUTHORIZATION MUST BE OBTAIN FROM THE OWNER PRIOR TO COMMENCEMENT OF ANY CUTTINGWELDING WORK. LANDLORD WILL GIVE AUTHORIZATION ONLY AFTER RECEIPTOF PROOF OF ABURNER'S/ WELDER'S PERMIT.

X. THE CONTRACTOR SHALL CONSULT WITH THE OWNER PRIOR TO COMMENCEMENT OF ANY WORKTO DETERMINE WHETHER THERE ARE ANY KNOWN HAZARDOUS SUBSTANCES IN OR NEAR THEPREMISES. IF ANY HAZARDOUS SUBSTANCES IN OR NEAR ARE DISCOVERED DURING CONSTRUCTIONALL WORK IS TO STOP IMMEDIATELY AND NOTIFICATION GIVEN TO THE OWNER.

XI. REMOVE DEMOLISHED MATERIALS, TOOLS AND EQUIPMENT FROM SITE UPON OF COMPLETION OFWORK.

XII. DELIVERY OF ITEMS WILL BE ALLOWED BETWEEN THE HOURS OF 9:00 AM and 4:00 PM. ALLDELIVERIES SHOULD CLEARLY IDENTIFY STORE NAME.

XIII. CONTRACTOR SHALL VERIFY FIELD CONDITIONS AND NOTIFY ARCHITECT OF ALL DISCREPANCIESBEFORE PROCEEDING WITH WORK.

XIV.CEASE OPERATION AND NOTIFY THE OWNER IMMEDIATELY IF SAFETY OF STRUCTURE APPEARS TOBE ENDANGERED. TAKE PRECAUTIONS TO PROPERLY SUPPORT STRUCTURE. DO NOT RESUMEOPERATIONS UNTIL SAFETY IS RESTORED.

XV. THE CONTRACTOR SHALL EMPLOY CLEAN UP PERSONNEL TO MAINTAIN THE WORK AREA IN ANEAT AND ORDERLY MANNER, INCLUDING ANY AREA BEYOND THE DUST TIGHT PARTITIONS WHEREWORK IS OCCURRING, WHERE TRAFFIC HAS OCCURRED WHILE IMPLEMENTING WORK, OR WHERE DUST,DIRT, OR DEBRIS HAS MIGRATED THE PARTITION. THESE PERSONNEL SHOULD BE RESPONSIVE TODIRECTION GIVEN BY THE CONTRACTOR AND BY THE LANDLORD THE LANDLORD WILL BE COORDINATEALL CLEAN UP REQUEST THROUGH THE CONTRACTOR. HOWEVER, WHEN DEEMED NECESSARY, THEOWNER WILL DIRECT CLEAN UP PERSONNEL DIRECTLY AND SUBSEQUENTLY NOTIFY THECONTRACTOR. IN CASES WHERE THE BUILDING'S STAFF MUST CLEAN UP CONTRACTOR'S WORK, THECOST OF SUCH WORK WILL BE BORNE BY THE CONTRACTOR.

XVI.ARRANGE PAY FOR DISCONNECTION, REMOVING AND CAPPING UTILITY SERVICES WITHIN AREASOF DEMOLITION. DISCONNECT AND STUB OFF. NOTIFY THE AFFECTED UTILITY COMPANY AND BUILDINGMANAGER IN ADVANCED AND OBTAIN APPROVAL BEFORE STARTING THIS WORK.

XVII. PLACE MARKERS TO INDICATE LOCATION OF DISCONNECTED SERVICES. IDENTIFY SERVICELINES AND CAPPING LOCATIONS ON PROJECT RECORD DOCUMENTS.

XVIII. PERFORM DEMOLITION IN ACCORDANCE WITH APPLICABLE AUTHORITIES HAVINGJURISDICTION.

XIX.REPAIR ALL DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED, AT NO COST TO THE OWNER.

XX. G.C. TO NOTIFY ASBESTOS INVESTIGATOR OF ANY SUSPICIOUS MATERIAL UNCOVERED DURINGDEMOLITION NOT NORMALLY ACCESSIBLE.

XXI.ALL EXHAUST GRILLES SHALL BE CLOSED AND COVERED TO PREVENT THE SPREAD OF DUST INTOTHE SYSTEM UNTIL CONSTRUCTION IS COMPLETE.

XXIV. ANY DISRUPTION OF THE ELECTRICAL, PLUMBING AND MECHANICAL TO THE BUILDING SHALLBE COORDINATED WITH THE BUILDING SUPER AND MANAGEMENT WITH THE LENGTH OF TIMEDISRUPTION INDICATED.

GENERAL REMOVAL NOTES

-

REMOVAL KEYNOTESNo. Description

-

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

1/4" = 1'-0"

A-100

REMOVAL PLANS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

1/4" = 1'-0"1

Penthouse F - 36th Floor - Main LevelRemoval Plan

R1

R12

R1 REMOVE EXISTING NON-STRUCTURAL PARTITION. PATCH CEILINGS, WALLS, AND FLOORS AS REQUIRED WITH MATERIALS TO MATCH EXISTING.

R2 REMOVE EXISTING WALL TILE FINISH AND BACKERBOARD IN BATHROOMS AND KITCHEN.

R3 REMOVE EXISTING DOOR AND FRAME. PATCH CEILINGS, WALLS, AND FLOORS AS REQUIRED WITH MATERIALS TO MATCH EXISTING.

R4 REMOVE EXISTING CASEWORK. PATCH CEILINGS, WALLS, AND FLOORS AS REQUIRED WITH MATERIALS TO MATCH EXISTING.

R5 REMOVE EXISTING COUNTERTOP AND BACKSPLASH.

R6 REMOVE EXISTING FLOOR FINISH DOWN TO SUB-FLOOR.

R7 REMOVE EXISTING RAISED PLATFORM. REMOVE ANY PLUMBING BELOW BACK TO RISERS. CAP AT CONNECTION WITH RISER.

R8 REMOVE EXISTING FANCOIL UNIT AND ENCLOSURE.

R9 REMOVE EXISTING PLUMBING FIXTURE AND ALL ASSOCIATED SUPPLY AND WASTE LINES BACK TO RISER. WELD CAP AT CONNECTION WITH RISER.

R10 REMOVE EXISTING KITCHEN APPLIANCE.

R11 REMOVE FINISH AROUND COLUMN TO EXPOSE STRUCTURAL CONCRETE.

R12 REMOVE EXISTING MANTEL, SURROUND, FLUE ENCLOSURE, AND HEARTH. EXISTING SOLID FUEL FIREBOX AND FLUE TO REMAIN.

R1

R4

R8

R8

R1 R1

R3

R3

R3

R7

R13

R13 REMOVE EXISTING STAIRCASE.

R1

R3 R9

R4

R4

R6

R6

R6R6

R6

R6

R5

R5R9

R10

R14 REMOVE EXISTING ELECTRICAL PANELS. DO NOT INTERFERE OR ALTER ELECTRICAL RISER. SEE E-100 FOR RELOCATION.

R14

R6

1/4" = 1'-0"2 Penthouse F - Upper Level Removal Plan

R6

R1

R1

R3

R2

R2

R3

R9

R18

R15 REMOVE EXISTING WALL FINISHES ABOVE AND BELOW GREENHOUSE GLAZING DOWN TO FRAMING. MAINTAIN EXISTING EXTERIOR FINISH ON SOUTH SIDE OFWALL. SEE CONSTRUCTION KEYNOTE 2 ON SHEET A-101.

R16 REMOVE EXISTING GREENHOUSE GLAZING AND KNEEWALL. PATCH AND REPAIR EXTERIOR WALLS AND FLOORS AS REQUIRED WITH MATERIALS TO MATCH EXISTING.

R16

R16

WALK -INCLOSET

MASTERBEDROOM

MASTERBATHROOM

GREENHOUSE

ROOF TERRACE

EXISTING FLUE ANDCOVERING TO REMAIN

R6

R6

R6

R1

R4

R4

R4

R6

R3

R1

R13

R15

R8

STAIRWELL

R6

R6R9

R3

UP

BALCONY

DINING

LIVINGKITCHEN

FOYERCL

CL

CL

CORRIDOR

BEDROOM

M. BATH

POWDER

R8R4

R4

R6

R17 SALVAGE EXISTING INTERCOM FOR RELOCATION.

R17

R17

R4

R18 DRAIN HOT TUB TO ROOF TERRACE WITH SYPHON PUMP BEFORE REMOVAL. CUT AND REMOVE TUB IN MANAGABLE SECTIONS, THEN REMOVE FRAMING.

R11

LAV WC

WC

LAV

SHOWER

PH-F

GAS RANGE

REF

SINKDW

FP

HOT TUB

SHOWER

WC

LAV

LAV

No. Description Date1 DOB Submission 02/06/2015

N N

NO WORK

R2

TYP

NO WORK

Page 3: Elam Pricing Full Set 4.3.15

I. ALL CONTRACTORS & THEIR SUB-CONTRACTORS SHALL VISIT, BECOME FAMILIARIZED, & VERIFY ALL EXISTINGCONDITIONS PRIOR TO SUBMITTING A PROPOSAL. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THATSUCH AN EXAMINATION HAS OCCURED & LATER CLAIMS WILL NOT BE RECOGNIZED FOR EXTRA LABOR, EQUIPMENT ORMATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN, HAD SUCH ANEXAMINATION BEEN MADE. THIS EXAMINATION IS TO INCLUDE BUT NOT LIMITED TO VERIFYING WEIGHT, STRUCTURALLIMITATIONS, CLEARANCES, & MANEUVERING SPACE ASSOCIATED W/REMOVAL OF LARGE EQUIPMENT FROM BUILDINGPREMISES, OR ANY SUCH FORSEEABLE SPECIAL REQUIREMENTS. CONTRACTOR SHALL INCLUDE A PRICE BREAKDOWN FORSPECIAL REQUIREMENTS DUE TO SITE RESTRICTIONS OR CONDITIONS.

II. ALL CONTRACTORS AND/OR SUB-CONTRACTORS SHALL OBTAIN DEMOLITION AND/OR CONSTRUCTION PERMITS AND / ORAUTHORIZATIONS FROM THE BUILDING DEPARTMENT, ARCHITECT, CLIENT, TENANT, AND / OR ENGINEERS AS REQUIREDPRIOR TO THE COMMENCEMENT OF WORK. A COPY OF SUCH DOCUMENTS SHALL BE FURNISHED TO THE OWNERS AND THEARCHITECT PRIOR TO THE COMMENCEMENT OF WORK.

III. WHILE PERFORMING DUTIES ASSOCIATED WITH THIS CONTRACT ALL CONTRACTORS, SUB-CONTRACTORS, AND THEIRWORKERS SHALL COMPLY WITH ALL OSHA RULES AND REGULATIONS & WITH THE STANDARD RULES AND REGULATIONS SETFORTH BY THE OWNERS.

IV. ALL CONTRACTORS AND THEIR SUB-CONTRACTORS SHALL COORDINATE THEIR WORK WITH OTHER TRADES AND WILLCONFER WITH ARCHITECT.

V. PROTECT ALL WINDOWS AND VENTS FROM DEBRIS AND DUST DURING CONSTRUCTION. KEEP PREMISES CLEAN AND DONOT LET DEBRIS, RUBBISH, OR EXCESS CONSTRUCTION MATERIAL ACCUMULATE OR OBSTRUCT EXITS AND EXITPASSAGEWAYS.

VI. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY ERRORS, OMISSIONS, CONFLICTS OR AMBIGUITIES WITHINAND BETWEEN THE PLANS, DRAWINGS, AND SPECIFICATIONS COMPRISING THESE CONTRACT DOCUMENTS PRIOR TOSUBMITTING HIS BID PROPOSAL. IF SUCH NOTICE IS NOT FURNISHED TO THE ARCHITECT, THE CONTRACTOR SHALL BEDEEMED TO HAVE INSPECTED THE PLANS, DRAWINGS, SPECIFICATIONS AND JOB CONDITIONS AND HAVE FOUND THEM INPROPER FORM FOR EXECUTION.

VII. THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR CONSTRUCTION MEANS, TECHNIQUES, SEQUENCES ORPROCEDURES, OR FOR THE SAFETY PRECAUTIONS IN CONNECTION WITH THE WORK.

VIII. DRAWINGS ARE NOT TO BE SCALED. FOLLOW DIMENSIONS SHOWN.

IX. NO CHANNELING, CUTTING OR CHOPPING OF ANY STRUCTURAL SLAB, ELEMENTS, DEMISING WALLS AND EXTERIORWALLS OR PIPE CHASE / SHAFT ENCLOSURE WALLS SHALL OCCUR DURING THE COURSE OF ANY WORK.

X. NO REMOVAL OF MASONRY BACK-UP MATERIAL AT EXTERIOR OR SHAFT WALLS SHALL OCCUR FOR INSTALLATION OFJUNCTION BOXES, ETC.

XI. ALL FIREPROOFING MUST BE MAINTAINED. ANY FIREPROOFING THAT IS DISTURBED DURING THE COURSE OF THERENOVATION IS TO BE RECONSTITUTED TO CODE COMPLIANT RATINGS.

XII. NO OFFSET OF RISERS (PLUMBING, GAS, ETC) SHALL OCCUR.

XIV.ALL PLUMBING SHALL BE DONE BY A NEW YORK CITY LICENSED PLUMBER AND ALL ELECTRICAL WORK BY A NYCLICENSED ELECTRICIAN IN ACCORDANCE WITH N.Y.C. BUILDING CODES AND REGULATIONS.

XV. PROVIDE NEW BRANCH LINES AT ALL NEW FIXTURES FOR WASTE, VENT AND SUPPLY LINES BACK TO THE RISERS, WITHNEW ACCESSIBLE SHUT-OFF VALVES AT RISER. WASTE LINES MUST BE RE-USED WHERE WHERE CURRENTLY LOCATED INTHE CONCRETE SLAB OR NEW LINES RUN ABOVE THE STRUCTURAL SLAB. INSTALL NEW SUPPLY BALL TYPE STOP VALVESFOR EACH LAV AND TOILET AND NEW BALL SHUT-OFF VALVES FOR THE BATHROOM AS A WHOLE. FIRE RATED ACCESSPANELS ARE REQUIRED AT ALL SHUT-OFF VALVES.

XVI.THE USE OF ELECTRICAL OR AIR HAMMER OR OTHER PNEUMATIC TOOLS ARE NOT PERMITTED TO BE USED DURINGCONSTRUCTION DUE TO THE NOISE FACTOR UNLESS SPECIAL PERMISSION IS GRANTED.

XVII. ALL NECESSARY ELECTRIC, GAS & WATER WORK MUST BE PERFORMED LOCALLY WITHIN THE APARTMENT. ALLNECESSARY SHUTDOWNS SHALL BE COORDINATED WITH THE BUILDING SUPER AND MANAGEMENT. SHUT DOWNS OFSERVICE RISERS TO RELOCATE ELECTRIC PANEL BOXES, SERVICE RISERS OR TO PERFORM PLUMBING WORK WILL NOT BEPERMITTED.

XVIII. PLUMBER TO PROVIDE BACKFLOW PREVENTORS AND BALL VALVES AT ALL PIPE OUT LOCATIONS.

XIX.REPLACE ALL SUPPLY, VENT AND SANITARY LINES BACK TO RISER AT KITCHEN. INSTALL NEW BALL TYPE SHUT-OFFVALVES AT SINK, DISHWASHER AND REFRIGERATOR WATER LINE, AND MASTER SHUT-OFF VALVES FOR KITCHEN AS AWHOLE.

XX. ALL WATER LINES ARE TO BE INSTALLED WITH THERMAL / ACOUSTIC INSULATION TO MINIMIZE SWEATING AND NOISETRANSMISSION, INCLUDING ELBOWS AND FITTINGS.

XXI.ISOLATE COPPER PIPING FROM DISSIMILAR MATERIAL TO PREVENT GALVANIC CORROSION.

XXII. NO PENETRATION THROUGH ANY EXTERIOR WALL IS PROPOSED NOR PERMITTED AS PART OF THIS ALTERATION.

XXIII. GC TO VERIFY THE LOCATION OF ALL EXISTING CONNECTIONS TO THE STACK. BUILDING MANAGEMENT TO INSPECTAND NOTIFY OF OTHER PLUMBING TO BE REPLACED.

XXIV. ALL EXHAUST GRILLES AND DAMPERS MUST BE MAINTAINED, REMAIN ACCESSIBLE AND IN OPERATION. UPONCOMPLETION OF WORK, ALL GRILLES AND DAMPERS ARE TO BE CLEANED.

XXV. GC TO TAKE MEASURES TO INSURE THAT OTHER PORTIONS OF THE BUILDING ARE NOT DAMAGED. ALL EXISTINGCONSTRUCTION ADJACENT TO PUBLIC AREAS OR OTHER APARTMENTS AFFECTED BY THE PROPOSED WORK IS TO BEPATCHED BACK TO IT'S ORIGINAL CONDITION USING MATCHING MATERIALS.

XXVI. NO STORAGE OR WORK IS PERMITTED IN COMMON AREAS AND FIRE STAIRS.

XXVII. PLUMBER MUST CHECK EXISTING WASTE AND VENT LINES TO BE FREE OF OBSTRUCTION.

XXVIII. CEMENT BOARD IS TO BE USED AT ALL SHOWER, TUB ENCLOSURES AND TILED AREAS. MOLD AND MOISTURERESISTANT WALL BOARD AT ALL OTHER DESIGNATED "WET AREAS".

XXIX. FIXTURE PIPING BETWEEN SHUT-OFF VALVE AND THE FAUCET OR APPLIANCE TO BE COPPER TUBING WITH FLAREDENDS AND BRASS BUSHINGS, OR BRASS COMPRESSION FITTINGS. (NO PLASTIC; RUBBER OR BRAIDED STAINLESS STEEL.HIGH PRESSURE "NO BURST" BRAIDED STAINLESS STEEL WILL BE ALLOWED TO HOOK-UP APPLIANCES THAT DO NOT HAVEACCESS AFTER INSTALLATION IF DEMONSTRATED THERE IS NO PRACTICAL ALTERNATIVE.)

XXX. THE CONTRACTOR SHALL MAINTAIN ADEQUATE, CLEARLY IDENTIFIED FIRE EXTINGUISHERS THROUGHOUT THE AREAOF WORK.

XXXI. GC TO PROVIDE A COMPLETE PHOTOGRAPHIC SURVEY OF THE ADJACENT APARTMENTS AND PUBLIC SPACES PRIORTO THE COMMENCEMENT OF ANY WORK TO IDENTIFY PRE-EXISTING CONDITIONS. A COPY OF THE SURVEY SHALL BEDELIVERED TO THE MANAGING AGENT.

XXXII. HOT AND COLD BRANCH LINES MUST BE REPLACED AT THE RISER'S CONNECTIONS.

XXXIII. FOUR-ELBOW SWING MUST BE INSTALLED ON THE HOT WATER BRANCH LINE.

XXXIV. WATTS PRESSURE REDUCING VALVES MODEL U5B-Z3 MUST BE INSTALLED ON THE HOT AND COLD WATER BRANCHLINES.

XXXV. SPRING LOADED CHECK VALVES MUST BE INSTALLED ON THE HOT AND COLD WATER BRANCH LINES.

XXXVI. APOLLO BALL VALVES MUST BE INSTALLED ON THE HOT AND COLD WATER BRANCH LINES.

XXXVII. PLUMBERS ARE REQUIRED TO USE TYPE L COPPER TUBING TO SUPPLY WATER TO TOILETS AND SINKS.

XXXVIII.PLUMBERS ARE PROHIBITIED FROM USING PLASTIC TUBING AND/OR RUBBER HOSES TO SUPPLY WATER TOREFRIGERATORS, DISHWASHERS, WASHING MACHINES, INSTANT HOT WATER MAKERS, TOILETS, SINKS AND WATERFILTERS.

XXXIX. PLUMBERS ARE REQUIRED TO INSTALL McGUIRE VALVES UNDER THE SINKS AND TOILETS. PLASTIC STEM VALVESARE PROHIBITIED.

XXXX. GARBAGE DISPOSALS ARE PROHIBITIED.

XXXXI. REGARDING INSTALLATION OF SHOWER STALLS, THE CONTRACTOR AND PLUMBER ARE REQUIRED TO INSTALL ATWO-INCH DRAIN WITH WEEP HOLES AND P-TRAP. TWO-INCH DRAIN MUST BE CONNECTED TO THE EXISTING STACK.

XXXXII. REGARDING INSTALLATION OF SHOWER STALLS, THE CONTRACTOR AND PLUMBER ARE REQUIRED TO USE A 6GUAGE LEAD PAN THAT RETURNS UP THE WALL A MINIMUM OF 12-INCHES.

XXXXIII. REGARDING INSTALLATION OF SHOWER STALLS, THE CONTRACTOR AND PLUMBER ARE REQUIRED TO APPLY A COATOF "BLACK MAGIC" TO THE TOP PORTION OF THE LEAD PAN. "BLACK MAGIC" EXTENDS THE LIFE OF THE PAN AND PREVENTSTHE LEAD PAN FROM DIRECT CONTACT WITH CEMENT WHICH CORRODES AND DAMAGES THE LEAD PAN.

XXXXIV. WHEN A WOODEN PLATFORM IS CONSTRUCTED TO CREATE A SHOWER STALL, THE CONTRACTOR IS REQUIRED TOUSE A MINIMUM OF 3/4-INCH THICK PLYWOOD.

XXXXVI. CONTRACTORS ARE PROHIBITED FROM DRILLING NAILS AND SCREWS THROUGH ANY PORTION OF THE LEAD PAN.

XXXXVII. REGARDING INSTALLATION OF WASHER AND DRYER UNITS, HOT AND COLD WATER VALVES MUST BE INSTALLED TOTHE SIDE OF EACH MACHINE FOR EASY ACCESS IN THE EVENT THE MACHINE NEEDS TO BE SERVICED.

XXXXVIII. REGARDING INSTALLATION OF WASHER AND DRYER UNITS, ALL FLOORING BENEATH MACHINES MUST BE WATERPROOFED AND SEALED.

XXXXIX. WASHER UNITS MUST BE SET ON VIBRATION ISOLATORS INSTALLED IN A WATERPROOF PAN.

XXXXX. REGARDING INSTALLATION OF WASHER AND DRYER UNITS, A FLOOD STOP KIT MUST BE INSTALLED ON THE HOTAND COLD WATER HOSES.

XXXXXI. REGARDING INSTALLATION OF WASHER AND DRYER UNITS, EASILY ACCESSIBLE BACKFLOW PREVENTORS NEED TOBE INSTALLED ON THE HOT AND COLD WATER BRANCH LINES.

XXXXXII. DRYER UNITS MUST BE VENTLESS TYPE UNITS. VENTED DRYER UNITS ARE PROHIBITED.

GENERAL CONSTRUCTION NOTES

UP

1

3

1

4

1

1

ALIGN

11

ALIGN

5' -

0"

8' -

6 1

/2"

1' -

10

3/4"

9' -

7 1

/4"

3

2

MIN CLEAR3' - 0"

6' -

0 3

/4"

5' -

1"

9' -

0 1

/4"

1' -

8"

VE

RIF

Y IN

FIE

LD

21' -

10"

13' - 2 3/4"VERIFY IN FIELD

9' - 2 1/4"

ALIGN

ALI

GN

A-2053

2

VE

RIF

Y IN

FIE

LD6'

- 1

1 3/

4"V

IF1'

- 1

0"

VERIFY IN FIELD18' - 6"

VIF2' - 10 1/4"

VERIFY IN FIELD7' - 8 1/2"

1

1

SD

SD

EXG

16R

15T

7

A-1013

A-1014

A-1015

4' - 6"

13' - 9 3/4"VERIFY IN FIELD

27' - 0 1/2"

VE

RIF

Y IN

FIE

LD26

' - 6

3/4

"

1

A-505

1

A-505

6

A-505

A-3031

ALIGN

A-2056

5

8

1

3

1

1

UP

16R

4

6

5

17' - 0 1/4"1 3/4"

1' - 11"

15' -

3"

DN

6"11

' - 1

0"

SD

6' -

8" SD

15T

1R 0T

8

2' -

2 1

/4"

1

A-302

MA

TC

H E

XT

EN

TS

OF

EX

G G

RE

EN

HO

US

E

10' -

5 3

/4"

± (V

ER

IFY

IN F

IELD

)

MATCH EXTENTS OF EXISTING GREENHOUSE BEING REMOVED17' - 3 3/4" ± (VERIFY IN FIELD)

4

A-505

A B

1

7

A-505

SD

1

A-506

FC

U-3

FC

U-1

2

CONSTRUCTION KEYNOTESNo. Description

CLE

AR

2' -

8"

MINIMUM1' - 6"

MINIMUM1' - 6" 1' - 6"

3

MINIMUM2' - 0"

MIN

1' -

0"

MIN

IMU

M2'

- 0

"

MINIMUM2' - 0"

MAX1' - 0"

MA

X

1' -

0"

MIN

IMU

M

1' -

6"

WC 4

8" X

56"

LAV 30" X 48"

SHOWER 30" X 48"

18" VERTICALGRAB BAR

WOOD BLOCKING (TYP)CLE

AR

2' -

8"

1

MINIMUM1' - 6"

WC 4

8" X

56"

LAV 30" X 48"

MINIMUM2' - 0"

6"

MIN

IMU

M

1' -

6"

18" VERTICALGRAB BAR

WOOD BLOCKING (TYP)

METAL RUNNER (TYP)

TOP OF FLOOR

5/8" GWB EACH SIDETO U/S OF CEILING

3 5/8 " METAL STUDS(MAY VARY) @ 16" O.C.

U/S OF CEILING

ROOM PARTITION F.H.

5/8" FIRE RATED GWBINTERIOR SIDE ONLY (2LAYERS FOR FIRE RATING)

U/S OF CEILING

ROXUL SAFE 'N'SOUND MINERALWOOL INSULATION

SOLID WOODSTRIP

5/8" GWB EACHSIDE TO U/S OFCEILING

1-1/2" METALSTUDS @ 16" O.C.

U/S OF CEILING

5/8" GWB. EACHSIDE TO U/S OFCEILING

U/S OF CEILING

J - BEAD METAL RUNNER (TYP)TOP OF FLOOR

20 GA METAL STUDS(SIZE VARIES) @ 16" O.C.

HILTI FIRE FOAM CP620J - BEAD

METAL RUNNEREACH SIDE (TYP)

TOP OF FLOOR

SOLID WOOD STRIP

J - BEAD(TY

P)

1FURRED-OUT WALL F.H.

2POCKET DOOR WALL F.H.

3PLUMBING CAVITY F.H.

4

PARTITION WALL TYPE#

EXISTING WALL

VIBRATIONISOLATION PADDING

HILTI FIRE FOAM CP620

WALL CLIPS AS NEEDED

Non Fire RatedSTC: 51-56

Fire RatingSTC Rating

Maintain EXG Fire Rating As Req'dSTC: 40-48

Non Fire RatedSTC: 40-44

Non Fire RatedSTC: 40-48

(SIZE VARIES)AIR SPACE

1/4"

1/4"

(TY

P)

(TY

P)

1/4"

POCKET DOOR CAVITY

1-1/2" METALSTUDS @16" O.C.METAL RUNNEREACH SIDE (TYP)

TOP OF FLOOR

SOLID WOODSTRIP

J - BEAD

1/4"

(TY

P)

CLEAR FLOOR SPACE

ø 5' - 6"

5' - 0"

6' -

7"

EXTENTS OF NEW/EXISTING WET AREA(SEE FLOOR DETAILS ON SHEET A-501)

FLOOR FINISH LEGEND

STONE TILE FLOOR FINISH(SEE FLOOR DETAILS ON SHEET A-501)

HARD WOOD FLOOR FINISH(SEE FLOOR DETAILS ON SHEET A-501)

Graphic Description

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

As indicated

A-101

CONSTRUCTION PLANS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

1/4" = 1'-0"1

Penthouse F - 36th Floor - Main LevelConstruction Plan

1/4" = 1'-0"2 Penthouse F - Upper Level Construction Plan

1 NEW RAISED PLATFORM UNDER STAIR. PLATFORM HEIGHT TO MATCH STAIR RISER HEIGHT.PLATFORM FLOOR FINISH TO MATCH STAIR TREAD FINISH. SEE SHEET A-303.

2 REINSULATE EXISTING FRAMING AND FINISH WITH GWB. DO NOT DISTURB OR ALTER EXISTINGEXTERIOR FINISH.

3 NEW DOOR, FRAME, AND HARDWARE. SEE DOOR REFERENCE CHART.

4 NEW KITCHEN CASEWORK. SEE ELEVATIONS ON SHEET A-202.

5 NEW REFRIGERATOR. EXTEND COPPER TUBE WATER SUPPLY TO ICE MAKER. SEE APPLIANCESCHEDULE ON SHEET A-600.

6 NEW DISHWASHER. SEE APPLIANCE SCHEDULE ON SHEET A-600.

7

8

9

NEW STAIRCASE WITH CONTINUOUS 1-3/8" WIDE HANDRAIL INSTALLED 36" HIGH.

10 NEW BUILT-IN STORAGE FURNITURE.

11 NEW WALL HUNG SHELVING UNIT. SEE DETAILS ON SHEET A-506.

12

NEW STONE MANTEL OVER EXISTING FIREPLACE. NO WORK TO FIREPLACE OR EXISTING FLUE.

13 NEW RECIRCULATING HOOD OVER GAS RANGE. SEE APPLIANCE SCHEDULE ON SHEET A-600.

14 NEW WALL MOUNTED TOILET. SEE PLUMBING FIXTURE SCHEDULE ON SHEET A-600.

15 NEW BATHROOM LAVATORY. SEE PLUMBING FIXTURE SCHEDULE ON SHEET A-600.

16

REPLACE PTAC UNIT AND ENCLOSURE. REPLACEMENT UNITS MUST BE CERTIFIED ANDINSTALLED BY A NYC LICENCED PLUMBER. REPLACEMENT ENCLOSURES MUST HAVE SERVICEACCESS PANELS AND INTERNAL DUCT (PAINTED MATTE BLACK) BETWEEN PTAC UNIT AND GRILL.

1

3

3

21

21

EXISTING EXPOSEDCONCRETE COLUMN

MASTERBEDROOM

MASTERBATHROOM

GREENHOUSE

ROOF TERRACE

STAIRWELL

LIVING

DININGKITCHEN

FOYER

CORRIDOR

BEDROOM

POWDER

10

10

EXISTING FLUEAND COVERINGTO REMAIN

17

NEW UNDERCOUNTER WINE STORAGE. SEE APPLIANCE SCHEDULE ON SHEET A-600.18

19 NEW INTEGRATED WINE STORAGE. SEE APPLIANCE SCHEDULE ON SHEET A-600.

20 NEW STACKABLE WASHER/SELF-CONDENSING DRYER. PROVIDE NEW FLOOR DRAIN ANDMETAL PAN MIN 3" CURB W/ WATER SENSOR AND AUTOMATIC SHUT OFF VALVE.

21

NEW ACCESS PANEL TO WATER SUPPLY SHUT OFF FOR AREA INDICATED.22

23

24

25

NEW STAINLESS STEEL UNDERMOUNT KITCHEN SINK. SEE PLUMBING FIXTURE SCHEDULE ONSHEET A-600.

REPLACE GREENHOUSE ENCLOSURE. SEE SHEETS A-301, A-302, AND A-503.NOTE: GREEHOUSE STRUCTURE APPROVED UNDER PRIOR NYC DOB APPLICATION #BH594-85.

NEW SKYLINE TERRACE DOOR AND TILT & TURN CASEMENT WINDOWS WITH FASTENERS @16" O.C. FINISH TO MATCH EXISTING FENESTRATION. SEE SHEETS A-301, A-302, AND A-503.

BALCONY

NEW SHOWER UNIT. SEE PLUMBING FIXTURE SCHEDULE ON SHEET A-600.

PARTITION TYPES

W/D

BATH

NO WORK

NO WORK

CL

2

7

19

26

10

3

REPLACE SKYLIGHT ABOVE(SEE DETAIL SHEET A-504)

8

8

8

8

15

15

11

9

14

13

5

17

10

14

1614

15

24

21

7

(TYP)

6

ENLARGED PLANS FORADA ADAPTABLE USE

1/2" = 1'-0"4 Main Level Bath Enlarged ADA Plan

1/2" = 1'-0"3 Main Level Powder Enlarged ADA Plan

NO WORK

NEW STAINLESS STEEL UNDERMOUNT BAR SINK. SEE PLUMBING FIXTURE SCHEDULE ON SHEETA-600.

22

203

1/2" = 1'-0"5 Main Level Kitchen Enlarged ADA Plan

DOOR REFERENCE CHARTMark Height Width Thickness Comments

1 8' - 0" 2' - 8" 1 1/2" 1ST FLR: POWDER RM2 7' - 10" 4' - 10 1/2" 2" 1ST FLR: BEDROOM3 8' - 0" 2' - 8" 1 1/2" 1ST FLR: BATHROOM4 7' - 10" 4' - 5 3/4" 2" 2ND FLR: MASTER BEDROOM5 8' - 0" 2' - 8" 1 1/2" 2ND FLR: MASTER BATHROOM6 6' - 8" 2' - 6" 2" 2ND FLR: GREENHOUSE7 7' - 9" 2' - 7" 3/8" 1ST FLR: BATH SHOWER8 7' - 8" 2' - 11 1/4" 3/8" 2ND FLR: MASTER BATH SHOWER9 7' - 11" 3' - 0" 1 3/4" 2ND FLR: GREENHOUSE

MAINTAIN CLEARANCETO ACCESS EXISTINGROOF DRAIN. VERIFYLOCATION IN FIELD.

EXISTING BATHROOMVENT EXTENDED TONEW LOCATION.

22

22

(M. BATH)

(GARDEN SINK)

(W/D)

LOWEREDCOUNTERTOP

NOTE: GREEHOUSE STRUCTUREAPPROVED UNDER PRIOR NYC DOBAPPLICATION #BH594-85

NOTE: ALL WALL DIMENSIONS SHOWN ARE FROM FINISH FACE TO FINISH FACE NOTE: ALL WALL DIMENSIONS SHOWN ARE FROM FINISH FACE TO FINISH FACE

REPLACE SKYLIGHT ABOVE(SEE DETAIL SHEET A-504)

23

16

4

12

18

4

4

(TYP)

(TYP)

26

NEW 5/8" SOLARBAN 60 INSULATED GLASS WINDOW UNITS. ALL FINISHES TO MATCH EXISTINGFENESTRATION. SEE SHEET A-505.

25

No. Description Date

NEW CERAMIC TILE WALL FINISH WITH BACKERBOARD IN WASHROOMS.

10

LAV

WC

WC

SHOWER

LAV

3

LAV

SHOWERHALL

WC

SINK

CL

CL

LAV

WC

SHOWERLAV

WC

SINK D/W

REF

F/P

REF

SINK

D/W

NEW GAS RANGE. PROVIDE ACCESSIBLE FIXTURE SHUT OFF VALVE IN KITCHEN. SEEAPPLIANCE SCHEDULE ON SHEET A-600.

REF

PENTHOUSE F

GA

S R

AN

GE

GA

S R

AN

GE

NOT TO SCALE

N N

3

24

Page 4: Elam Pricing Full Set 4.3.15

CU-1

1

A-302

1

A-504

TYP

1

A-504

TYP

3

A-504

TYP

A B

1

I. ANY ALTERATION TO ROOFING DURING REMOVAL AND CONSTRUCTION MUST BE PERFORMED BYTHE BUILDING'S ROOFING CONTRACTOR (YORK RESTORATION CORP.) TO MAINTAIN WARRANTY.

GENERAL ROOF NOTES

REMOVAL KEYNOTESNo. Description

CONSTRUCTION KEYNOTESNo. Description

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

1/4" = 1'-0"

A-102

ROOF PLANS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

1/4" = 1'-0"2

Penthouse F - Upper Level RoofConstruction Plan

1/4" = 1'-0"1

Penthouse F - Upper Level Roof RemovalPlan

EXISTING ROOFDRAIN TO REMAIN(DO NOT DISTURB)

EXISTING FLUE ANDCAP TO REMAIN(DO NOT DISTURB)

EXISTING 4" Ø VENTPIPE TO REMAIN

EXISTING JUNCTIONBOX TO REMAIN

EXISTING FIRE SAFETYRAILING TO REMAIN(DO NOT DISTURB)

SEE DRAWING 3 ON M-100FOR MECHANICAL WORK

No. Description Date

UPPER LEVEL ROOF

D1 REMOVE EXISTING GREENHOUSE INSULATED GLASS ENCLOSURE.

D2 REMOVE PORTION OF EXISTING KNEE WALL DOWN TO HEIGHT OF GREENHOUSE FLOOR SUBSTRATE.

D3 REMOVE EXISTING SKYLIGHT. COORDINATE WITH REPLACEMENT INSTALLATION. SEE GENERAL ROOF NOTE I.

D4 REMOVE EXISTING AIR HANDLER. EXISTING MECHANICAL EQUIPMENT SLAB TO REMAIN. SEE GENERAL ROOF NOTE I.

D5 REMOVE EXISTING DUCTING AND SUPPORTS BETWEEN AIR HANDLER AND ROOF SLEEVE. SEE GENERAL ROOF NOTE I.

D6 REMOVE EXISTING ROOF SLEEVE. COORDINATE WITH ROOF REPAIR WORK TO FILL OPENING. SEE GENERAL GENERAL ROOF NOTE I.

D7 REMOVE EXISTING AIR HANDLER ELECTRICAL WIRING AND REFRIGERANT LINES BACK TO JUNCTION BOX.

UPPER LEVEL ROOF

ROOF TERRACE BELOW ROOF TERRACE BELOWNO WORK NO WORK

GREENHOUSE INSULATEDGLASS ENCLOSURE BELOW

1 NEW AIR HANDLER MOUNTED ON EXISTING EQUIPMENT PAD. SEE MECHANICAL DRAWINGS. SEE GENERAL ROOF NOTE I.

2 NEW TAPERED STEEL ROOF BEAM OF NEW GREENHOUSE ENLOSURE. SEE SHEETS A-502 AND A-503.

3 NEW STRUCTURAL INSULATED PANEL BETWEEN TAPERED ROOF BEAMS TO EXTENTS SHOWN.

4 NEW "THERMALGAL" TRANSLUCENT INSULATED STRUTRURAL POLYCARBONATE (POLYGAL) SHEET BETWEEN TAPERED ROOF BEAMS TO EXTENTS SHOWN.

5 NEW SKYLIGHT AT EXISTING LOCATION. SIZE TO MATCH EXISTING ROOF OPENING. SEE GENERAL ROOF NOTE I.

6

REPAIR ROOF OPENING. FRAME, INSULATE, AND FINISH TO MATCH EXISTING INTERIOR AND EXTERIOR. SEE GENERAL ROOF NOTE I.7

NEW SAFETY RAIL SOURCE SAFETY ROOF SCREEN INSTALLED ON FRAME OF NEW SKYLIGHT OVER STAIRWELL. SEE GENERAL ROOF NOTE I.

D1

D2

D3

D3

D4

D5

D6

D7

1

2

TYP

3

4TYP

5

56

7

PITCH

PITCH

NEW CONTINUNOUS COIL STOCK ROOF GUTTER WITH COPPER RAIN LEADER PITCHED TOWARD EXISTING ROOF DRAIN.8

8

EXISTING TERRACEDEMISING WALL TO REMAIN

EXISTING PARAPETWALL TO REMAIN

(DO NOT DISTURB)

EXISTING METAL SAFETYRAILING TO REMAIN(DO NOT DISTURB)

EXISTING PARAPETWALL TO REMAIN(DO NOT DISTURB)

8

Page 5: Elam Pricing Full Set 4.3.15

33

3

3

4

3

2

A-507

2

A-507

1

A-507

TYP

TYP

TYP

1

A-507

TYP

1

A-507

TYP

1

A-507

SIM

OPEN TO ABOVE

L-R1 L-R1

L-R1 L-R1

L-R1L-R1

L-R1 L-R1 L-R1

L-R1 L-R1

L-R1 L-R1 L-R1

L-R1

L-R1L-R1

L-R1L-R1

L-R1

EXPOSED UNDERSIDEOF EXISTING FLOOR

SLAB ABOVE

3

A-507

TYP

3

A-507

TYP

3

A-507

TYP

EXPOSED UNDERSIDE OFEXISTING FLOOR SLAB ABOVE

EXPOSED UNDERSIDE OFEXISTING FLOOR SLAB ABOVE

L-R3L-R3

L-R4 L-R4

L-R2

L-R2

L-R2

L-R2 L-R2 L-R2 L-R2

L-R2

L-R2

L-R2 L-R2 L-R2

L-P2 L-P2 L-P2

L-RL1

L-RL1

WALL MOUNTEDSMOKE DETECTORS(MOUNT 6"-12" FROM

CEILING FINISH)

L-RL1

L-R1

L-R2

L-R2

L-R2

L-RL1

L-RL2

L-RL2 L-RL2

3

U/L 3-WAYSWITCH

L-RL1

RAISED PLATORM BELOW

16' -

8"

8' - 6"

9' - 3"

5' -

0"

1' -

8"

L-RL1

L-RL2

L-WM2

L-WM2

L-WM1

L-WM1

3

A-507L-RL2

L-R2 L-R2

CF-3

CF-3

CF-3 CF-3

CF-3

MOTORIZED CEILING SHADE MOTORIZED CEILING SHADE

CF-2

CF-2

ALIGN

CF-1

CF-1

CF-1

CF-1

CF-1

CF-1CF-5

CF-2

CF-1

L-P1

L-R3 L-R3

L-R

6

L-R

6DR

CF-2

L-WM3

RAISED PLATORM BELOW

2

A-507

TYP

WALL MOUNTED SMOKE DETECTOR(MOUNT 6"-12" FROM CEILING FINISH)

A B

1

L-R5 L-R5

L-R5 L-R5

L-R5 L-R5

L-R1 L-R1 L-R4

L-R4 L-R5

L-R5 L-R5

L-R5

L-R5

L-R5

L-P2L-P2

16' - 9"

L-S1

L-S1

L-S1

L-S1

3

OUT TO TERRACE

4

4

4

L-RL2

T

M/L 3 WAY SWITCHL-TL1M/L 3 WAY SWITCH

MASTER BED CUSTOMCASEWORK BELOW

L-RL2

TREADBELOW

L-RL1

EXPOSED UNDERSIDE OFEXISTING SLAB ABOVE

CF-3

STEEL BEAMTYP

4

A-507

CF-1

CF-1

CF-1

CF-1

L-R6

L-R6

L-R6

L-R6

L-R6

L-R6

L-R

6

L-R

6

CF-1

DR

DR

DR

DR

DR

L-R

6

L-R

6

CF-1

CF-1

L-P2

L-WM4 CF-1

CF-6

CASEWORKBELOW

L-S2 L-S2 L-S2 L-S2 L-S2 L-S2 L-S2

L-WM5

4

A-507

TYP

TYP

CF-6CF-6CF-6 CF-6 CF-6 CF-6

L-TL1

WALL MOUNTED SMOKE DETECTOR(MOUNT 6"-12" FROM CEILING FINISH)

4

4

4

L-WM6 L-WM6

SINGLE POLE WALL MOUNTED SWITCH

SYMBOL DESCRIPTION

ELECTRICAL LIGHTING LEGEND

3 WAY WALL MOUNTED SWITCH

4 WAY WALL MOUNTED SWITCH

JAMB MOUNTED DOOR SWITCHDR

1" RECESSED LED

4" RECESSED HALOGEN

4" RECESSED LED (SHOWER)

WALL MOUNTED SCONCE

CEILING MOUNTED TRACK LIGHTING

WALL MOUNTED SURFACE FIXTURE

ROPE LIGHT

CEILING MOUNTED SURFACE FIXTURE

PENDANT MOUNTED LIGHT FIXTURE

CEILING MOUNTED SURFACE FIXTURE

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

1/4" = 1'-0"

A-103

REFLECTED CEILING PLANS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

1/4" = 1'-0"1

Penthouse F - 36th Flr - Main LevelReflected Ceiling Plan

1/4" = 1'-0"2

Penthouse F - Upper Level RefelectedCeiling Plan

No. Description Date

LIGHTING FIXTURE SCHEDULEDesig. Cnt Description Housing / Trim Lamp Manufacturer Product ID Location(s)L-P1 1 PENDANT MOUNTED (OWNER PROVIDED) NA INCANDESCENT 1ST FLR: DININGL-P2 3 PENDANT MOUNTED (OWNER PROVIDED) NA T5 Delray Lighting 6311 2MD FLR: STAIRWELLL-R1 23 LOW VOLTAGE HALOGEN TRIMLESS HALOGEN (12OV, 277V, OR 347V) USAI 9004-10-C-FL100-120 1ST FLR: FOYER/LIVING/DINING SOFFITSL-R2 17 LOW VOLTAGE HALOGEN 4" LOW VOLTAGE REMODEL HOUSING MR16 (12V/50W) WAC LIGHTING HR-8401E 1ST FLR: LIVING/DINING & KITCHEN DROP CEILINGL-R3 4 1" LEDme MINI RECESSED ADJUSTABLE SPOT NA / LOW PROFILE TRIM WARM/NEUTRAL LED (3W) WAC LIGHTING HR-LED272R 1ST FLR: POWDER ROOM CEILINGL-R4 4 4" LEDme NEW CONSTRUCTION HOUSING / SHOWER TRIM 6 x WARM/NEUTRAL LED (3W) WAC LIGHTING HR-LED418-N 1ST FLR: BATHROOM SHOWER CEILING 2ND FLR: MASTER BATHROOM SHOWER CEILINGL-R5 12 3.5" TESLA LED NA / DOWNLIGHT TRIM LUXEON S MULTI-CHIP LED (18W) WAC LIGHTING HR-3LED-T718 2ND FLR: STAIRWELL CEILING, HALL CEILING, MASTER BEDROOM DROP CEILINGL-R6 12 1" LEDME MINI RECESSED ADJUSTABLE SPOT NA / LOW PROFILE TRIM WARM/NEUTRAL LED (3W) WAC LIGHTING HR-LED272R 1ST FLR: BEDROOM CLOSET CLG 2ND FLR: W/D CLG, ELEC CLOSET CLG, M. BEDROOM CLOSET CLGL-S1 3 SURFACE MOUNTED (OWNER PROVIDED) 2ND FLR: MASTER BEDROOM DROP CEILINGL-S2 7 SURFACE MOUNTED (OWNER PROVIDED) 2ND FLR: GREENHOUSE BAY CEILINGSL-TL1 1 14' LED TRACK LIGHTING (OWNER PROVIDED) 2ND FLR: MASTER BEDROOM CEILING (WEST)

L-WM1 2 WALL MOUNTED (OWNER PROVIDED) 1ST FLR: POWDER ROOM (BEHIND MIRROR)L-WM2 2 WALL MOUNTED (OWNER PROVIDED) 1ST FLR: BATHROOM (ABOVE MIRROR)L-WM3 1 WALL MOUNTED (OWNER PROVIDED) 1ST FLR STAIRWELL (WALL MOUNTED ABOVE STAIR PLATFORM)L-WM4 1 WALL MOUNTED (OWNER PROVIDED) 2ND FLR: MASTER BATHROOM (WALL MOUNTED W/ MIRROR SURROUND)L-WM5 1 WALL MOUNTED (OWNER PROVIDED) 2ND FLR: MASTER BEDROOM (WALL MOUNTED)L-WM6 2 WALL MOUNTED (OWNER PROVIDED) 2ND FLR: MASTER BEDROOM (WALL MOUNTED)

Page 6: Elam Pricing Full Set 4.3.15

FF-1

FF-1

FF-1

FF-3

FF-2

FF-2

FF-2

FF-2

FF-6

FF-6

2

A-505

2

A-505

1

A-505

1

A-505

6

A-505

2' -

7 1

/4"

2' -

4 3

/4"

1' - 7" 3' - 4"

A B

1

FF-4FF-4

FF-5

FF-6

FF-5

FF-5

FF-24

A-505

1

A-302

7

A-505

FLOOR FINISH SCHEDULEDESIGNATION SIZE/MATERIAL FINISH MANUFACTURER LOCATION(S)

FF-1 3/8"x12"x24" PORCELAIN FLR TILE MATTE NASCO STONE & TILE

SERIES/COLOR

FUSSION, DARK ANTHRACITE

FF-3

3/8"x6"x24" PORCELAIN FLR TILE MATTE PROVENZAW-AGE, CORTEX NERO

FF-5 3/4" VENEERED PLYWOOD FLOOR SATIN CLEAR TBDEAST INDIAN ROSEWOOD

1ST FLR: FOYER, LIVING, DINING, KITCHEN, BEDROOM, BATHROOM

FF-6 3/4" SOLID WOOD RUBBED MONOCOAT MATTEWALNUT 1ST FLR: STAIR TREADS, KITCHEN CUSTOM CASEWORK

2ND FLR: MASTER BEDROOM, MASTER BATHROOM, GREENHOUSE

2ND FLR: MASTER BATHROOM & SHOWER

FF-2 3/8"x40"x40" PORCELAIN FLR TILE MATTE NASCO STONE & TILEFUSSION, DARK ANTHRACITE 1ST FLR: POWDER RM

FF-4

3/8"x6"x36" PORCELAIN WALL TILE MATTE DALTILEACACIA VALLY, ASH 1ST FLR: BATHROOM SHOWER

TBD

REMARKS

FIELD CUT AS NOTED IN PLAN

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

As indicated

A-104

FLOOR FINISHES PLANS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

1/4" = 1'-0"1

Penthouse F - 36th Floor - Main Level FloorFinishes Plan

1/4" = 1'-0"2

Penthouse F - Upper Level Floor FinishesPlan

No. Description Date

FLOOR TILE EXTENDSBENEATH TOE KICK

Page 7: Elam Pricing Full Set 4.3.15

A-202 4

1

3

-

2

6

A-202

AP-1

-

---

1

A-506

2' - 2"

ALIGN

ALIGN

AP-2

WOOD PANEL

MARINE EDGE SS-1

SS-1

CT-1

CT-1

AP-3

5

A-202

8

A-202 4

1

3

2

- -

ROLL OUT

SH

ELF

PULL OUT

PULL OUT

DRAWER

AP-1

AP-5SINK BASIN

AP-4

AP-3

DRAWERSHELFALIGN

-

---

1

A-506

STEEL ANGLE SUPPORTBENEATH FLOATING CABINETS

COUNTERTOP ABOVE

EXISTING CASTIRON RADIATOR

RECESSED TOE KICK

5

A-202

8

A-202 4

1

3

-

2

6

A-202

FC

U-1

EN

CLO

SU

RE

FC

U-1

UNISTRUT(TYP)

HOOD DUCT

DRAWER

DRAWER

-

---

1

A-506

9' - 3"

L-R1

L-R1

L-R1

L-R1

L-R1

L-R1

L-R1

L-R1

L-R1

GLASS SHELF

GL-1

GL-1

CW-1CW-1

5

A-202

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

1" = 1'-0"

A-201

KITCHEN ENLARGED PLANS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

1" = 1'-0"2

Penthouse F - 36th Floor - Main LevelKitchen Enlarged Plan

1" = 1'-0"1

Penthouse F - 36th Floor - Main LevelKitchen Enlarged Plan (Base)

1" = 1'-0"3

Penthouse F - 36th Floor - Main LevelKitchen Enlarged Plan (Upper)

No. Description Date

Page 8: Elam Pricing Full Set 4.3.15

T ecton ic Cop yright 2007

T ecton ic Cop yright 2007

AP-4 AP-5

AP-2

AP-1

1/2" 2' - 0" 3/4" 2' - 3" 3/4" 2' - 3" 3/4" 2' - 6" 1' - 11 1/2" 5 1/2"

-

---

CW-1 CW-1 CW-1

CW-1CW-1

CW-1

CW-1

GFI

CW-1CT-1 CT-1

5

A-202

EXISTING CAST IRONRADIATOR BEYOND

AUTOMATIC ROLLER SHADE

L-R1 L-R1 L-R1

7 3/

4"11

1/2

"1'

- 3

1/2

"1

1/2"

5' - 10"

EXISTINGCONCRETE

COLUMNEXPOSED

AP-4CW-1

CW-1CW-1

CW-1

EXISTING CAST IRONRADIATOR BEYOND

EQ EQ EQ EQ EQ

CT-1

3' -

0"

2-1/2"x2-1/2"x3/16" STEEL ANGLE

UNISTRUT SUPPORTS (TYP)

L-R1L-R1L-R1

AP-4

1

A-506A-202

6

CW-2 CW-2

CW-2CW-2

CW-2

CW-2

CW-2

4

A-506

CW-1

GL-1 GL-1

SS-1

EXISTING CONCRETECOLUMN EXPOSED

CT-1

6

A-202

AP-1

AP-2

1 1/2" 7 1/2" 2' - 6" 7 1/2" 1 1/2" 2' - 6" 1 1/2"

AP-3

RECIRCULATING HOOD DUCT

GFI GFI

FCU-1 UNIT

EXHAUST DUCTFCU-1 UNIT

CW-1

CW-1

CW-1

SS-1

GFI

CW-1 CW-1

WF-1

SS-1 SS-1

A-2025

CW-1

CW-1 CW-1

CW-1

L-R1 L-R1 L-R1

10 3

/4"

2' -

1 1

/2"

6"

1 1/

2"

FCU-1

HOOD

DU

CT

DUCT DUCT

UNISTRUT

UNISTRUT

AP-2

DRAWER

VE

NT

5" M

IN.

CT-1

TOE KICK VENT

EXISTING CASTIRON RADIATOR

1 1/

2"

1/8" EASED EDGE(TYP)

RECESSED PULL

SHELF

IN FRONT OF RADIATORSHALLOW CABINET ONLY

SHELF

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

As indicated

A-202

KITCHEN ELEVATIONS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

1" = 1'-0"1 Kitchen Elevation - North

1" = 1'-0"3 Kitchen Elevation - West

1" = 1'-0"2 Kitchen Elevation - South

1" = 1'-0"4 Kitchen Elevation - East

1" = 1'-0"6 Range/Hood/FCU-1 Section

No. Description Date

1 1/2" = 1'-0"5 Kitchen Recessed Casework Section

Page 9: Elam Pricing Full Set 4.3.15

A-203

12

13

14

15

SHELF

SH

ELF

FF-4FF-4

PL-7

PL-11

A-20310

7

8

9

FF-1

FF-3

A-203

4

3

2

5

FF-2

FF-2

FF-2

FF-6

CT-3

PL-5

PL-10

MR-1

P-1

MEDICINECABINET

WF-3

WF-3

WF-3CT-3

MR-1

WF-1

A-5056

P-1

WF-3

WF-3GFI

CT-3

L-R4

L-WM2 L-WM2

PL-10

PL-6

SLIDE

WF-1

A-5056

P-1

3

L-R4

WF-3

7

G2

WF-1

FF-1

PL-6

CF-1

WF-3

SLIDE

MIRROR

A-5056

P-2

5

FF-4 FF-4

P-2

MR-1

8 G3

FF-4

TRANSOM WINDOW7' - 8"

MR-1

WF-3

MR-1

A-5056

WF-4

WF-4

SS-1

CT-2

CT-2

G3

P-2 P-2

FF-4

L-WM4

MR-1 MR-1

MR-1

SS-1

CW-3

CW-3

CW-3

WF-4

WF-3

WF-4

MR

-1

L-WM4

WC-1

WF-2

WF-2

CT-3

L-WM1

MR-1

WC-1

WF-2 MR-1

CT-3

L-WM1 L-WM1

P-1

WF-4

PL-10

PL-5CW-3

WF-4WF-4

WF-4

WF-4WF-4WF-4

CT-3

L-WM1MR-1

SLIDE

WF-2

G1

WC-1

WF-4

1

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

1/2" = 1'-0"

A-203

BATHROOM ENLARGED PLANS &ELEVATIONS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

1/2" = 1'-0"11

Penthouse F - Upper Level Master BathEnlarged Plan

1/2" = 1'-0"6

Penthouse F - 36th Floor - Main Level BathEnlarged Plan

1/2" = 1'-0"1

Penthouse F - 36th Floor - Main LevelPowder Room Enlarged Plan

1/2" = 1'-0"7 Bathroom Elevation - North

1/2" = 1'-0"8 Bathroom Elevation - East

1/2" = 1'-0"10 Bathroom Elevation - West

1/2" = 1'-0"9 Bathroom Elevation - South

1/2" = 1'-0"12 Master Bath Elevation - North

1/2" = 1'-0"13 Master Bath Elevation - East

1/2" = 1'-0"14 Master Bath Elevation - South

1/2" = 1'-0"15 Master Bath Elevation - West

1/2" = 1'-0"2 Powder Elevation - North

1/2" = 1'-0"3 Powder Elevation - East

1/2" = 1'-0"4 Powder Elevation - South

1/2" = 1'-0"5 Powder Elevation - West

No. Description Date

PL-6

PL-10

Page 10: Elam Pricing Full Set 4.3.15

A-2045 3

4

2

3' -

0"

3' -

0"

1' -

6"

1' -

4 3

/4"

S/D

C1

P-2

P-2

SLIDE

3

S/D

P-2

P-2

P-2

7"6'

- 6

3/4

"2'

- 4

"

ATUO ROLLER SHADE POCKET BEYOND

PTAC UNIT

EXISTING SLIDING WINDOW

2' - 6" 3' - 5" 2' - 6"

CW-1 CW-1

CW-1

CW-1 CW-1

P-2

P-2

WB-1

8' - 8" 8' - 3" 4' - 4"

1' -

7"

1' -

5"

1' -

6 3

/4"

1' -

6 3

/4"

1' -

8 1

/2"

SLIDE

60" FLAT SCREEN TV

2

3' - 6 3/4"

P-2P-2

P-2

P-2

CW-5

CW-5

CT-5

PTACUNIT

CT-5

L-R2L-R2L-R2

CW-5CW-5

A-204

7

8

9

10

14' -

3"

1' -

0"

4' -

2 3

/4"

1' -

0"

6' -

6"

1' -

0"

2' -

6"

8' - 6" 3' - 0"

5' -

2 3

/4"

6' -

6" A-5067

A-506 6

4

A-507

EXG SLIDING WINDOW

L-TL1

L-WM6 L-WM6

BED FRAMEBY OWNER

P-3

P-3

MASTERCLOSET

P-3

A-5065

A-5074

OPP

L-R5 L-R5 L-S1

SLIDESLIDE

S/D L-WM5

4 5

P-3

P-3

L-TL1

P-3

ACCESS TOW/D SHUTOFFS

MASTERCLOSET

L-R5 L-R5L-S1

A-5074

TYP

A-5074TYP

A-5074 OPP

S/D

C4C4C4

P-3

L-S1 L-S1 L-S1

P-3 P-3 P-3

EXISTING SLIDING WINDOW

L-TL1

EXISTING FLUE & COVER

L-TL1

P-3

P-3

P-3

WB-1

UPHOLSTERED CUSION

PTAC UNIT

CW-3

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

1/2" = 1'-0"

A-204

BEDROOM ENLARGED PLANS &ELEVATIONS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

1/2" = 1'-0"1

Penthouse F - 36th Floor - Main LevelBedroom Enlarged Plan

1/2" = 1'-0"4 Bedroom Elevation - South

1/2" = 1'-0"3 Bedroom Elevation - East

1/2" = 1'-0"2 Bedroom Elevation - North

1/2" = 1'-0"5 Bedroom Elevation - West

1/2" = 1'-0"6

Penthouse F - Upper Level Master BedroomEnlarged Plan

1/2" = 1'-0"7 Master Bedroom Elevation - North

1/2" = 1'-0"9 Master Bedroom Elevation - South

1/2" = 1'-0"8 Master Bedroom Elevation - East

1/2" = 1'-0"10 Master Bedroom Elevation - West

No. Description Date

Page 11: Elam Pricing Full Set 4.3.15

A-2053

2

AP-6

AP-6

P-1

CW-3 MR-1

CW-1

L-R2 L-R2 L-R2

A-5073OPP

AP-6

EXISTINGENTRY DOOR

OUTSIDE CORNEROF POWER RM WALL

WC-2

WC-2WC-2

CW-4

WF-5

WF-5

WF-5

WF-5

WB-1

L-R2L-R2L-R2 L-R2L-R2

A-5073 TYP

1

A-507

EXISTING WOODBURNING FIREPLACE

AND MANTEL

P-1

CW-4PTAC UNIT PTAC UNIT

CW-4 CW-4

P-1

EXISTING SLIDING WINDOW EXISTING SLIDING WINDOW

A-5072

TYP

A-5072

OPP

WB-1 WB-1

L-R1 L-R1 L-R1 L-R1 L-R1L-R2

CT-4 CT-4

WF-6 WF-6

EXISTING SLIDING DOOR

SLIDE

FLUE

L-P1

RACEWAY FORL-P1 WIRING

P-1

L-R1L-R1

A-5072

TYP

A-5072OPP

PTAC ENCLOSURE BEYOND

4

A-303

2

SLIDE

4

A-506

ROLL OUT

ROLL OUT

CW-1CW-2

CW-1

CW-1

P-1

P-1

P-1

P-1

L-P2

EXISTINGCONCRETE

COLUMNEXPOSED

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

1/2" = 1'-0"

A-205

MAIN FLOOR ENLARGED PLANS &ELEVATIONS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

1/2" = 1'-0"1

Penthouse F - 36th Floor - Main Level FoyerEnlarged Plan

1/2" = 1'-0"3 Foyer Elevation - West

1/2" = 1'-0"2 Foyer Elevation - South

No. Description Date

1/2" = 1'-0"6 Living/Dining Elevation - West

1/2" = 1'-0"5 Living/Dining Elevation - North

1/2" = 1'-0"8 Living/Dining Elevation - East

Page 12: Elam Pricing Full Set 4.3.15

A-206

5

4

2

3

FC

U-2

3' - 2 1/4"

2' -

6"

4' -

5"

2' -

6"

2

A-302

6 3/

4"9'

- 1

1"

A B

1

3' - 2" 3' - 2" 3' - 2" 3' - 2" 3' - 2" 11"

PL-9

PL-13

AP-9

CT-3

FF-5

FF-5

CT-3

8 1/

4"

3/4"

8 1/

4"

3/4"

8 1/

4"

3/4"

1' -

5"

AP-10

3' - 8"TRANSOM WINDOW TO MASTER BATHROOM

7' - 8"1' - 10 1/4"

A B

6

W2MR-1

PL-9

WB-1WB-1

P-4

P-4

P-4

ACCESS TO MASTERBATHROOM CLEAN OUT

FCU-2

PL-13

MR-1

1' -

3 1

/2"

MATCH FINISH MATCH FINISHS/D

AP-9

AP-10

2' - 1 1/2"1 1/2"

MR-1

P-4

P-4

CW-1

CW-1

PL-13

PL-9

P-4

CW-1

CT-3

FCU-2

WF-4

1

W2

W2

W2

WB-1

P-4P-4

AB

W1 W1W1 W19

FCU-2

WF-4 WF-4 WF-4 WF-4 WF-4 WF-4 WF-4

STEEL ROOF BEAM(TYP)

STEEL ROOF BEAM(TYP)

CF-6(TYP)

CF-6(TYP)

CF-6(TYP)

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

3/4" = 1'-0"

A-206

GREENHOUSE ENLARGED PLAN &ELEVATIONS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015 3/4" = 1'-0"

1

Penthouse F - Upper Level GreenhouseEnlarged Plan

3/4" = 1'-0"2 Greenhouse Elevation - North

3/4" = 1'-0"3 Greenhouse Elevation - East

3/4" = 1'-0"4 Greenhouse Elevation - West

3/4" = 1'-0"5 Greenhouse Elevation - South

No. Description Date

P-4

Page 13: Elam Pricing Full Set 4.3.15

GF

I

FC

U-2

2

A-302

TYP

2' - 3" 2' - 3" 2' - 3" 2' - 3" 2' - 3" 2' - 3" 2' - 3"

HSS 5x5

x1/2

HSS 5x5

x1/2

6" 15' - 9" 6"

3/8"

TH

ICK

TA

PE

RE

D S

TE

EL

BE

AM

(T

YP

OF

8)

3/8"

TH

ICK

TA

PE

RE

D S

TE

EL

BE

AM

(T

YP

OF

8)

A B

1

2' -

0"

10' -

2 1

/2"

1

A-302

17' - 3 3/4"

3/8"

TH

ICK

TA

PE

RE

D S

TE

EL

BE

AM

(T

YP

OF

8)

3/8"

TH

ICK

TA

PE

RE

D S

TE

EL

BE

AM

(T

YP

OF

8)

3/8"

TH

ICK

TA

PE

RE

DS

TE

EL

BE

AM

(T

YP

OF

8)

3/8"

TH

ICK

TA

PE

RE

DS

TE

EL

BE

AM

(T

YP

OF

8)

3/8"

TH

ICK

TA

PE

RE

DS

TE

EL

BE

AM

(T

YP

OF

8)

3/8"

TH

ICK

TA

PE

RE

DS

TE

EL

BE

AM

(T

YP

OF

8)

3/8"

TH

ICK

TA

PE

RE

DS

TE

EL

BE

AM

(T

YP

OF

8)

3/8"

TH

ICK

TA

PE

RE

DS

TE

EL

BE

AM

(T

YP

OF

8)

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

1" = 1'-0"

A-301

GREENHOUSE FRAMING PLAN

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

No. Description Date

1" = 1'-0"1

Penthouse F - Upper Level GreenhouseEnlarged Framing Plan

EXISTING TERRACE DRAIN(DO NOT DISTURB)

Page 14: Elam Pricing Full Set 4.3.15

EXISTING ROOF ASSEMBLY

EXISTING SLEEPERS

EXISTING RIGID INSULATION

EXISTING PLYWOOD SUB-FLOOR

NEW BACKERBOARD

NEW STONE TILE FLOORING

EXISTING CMU KNEE WALLMODIFIED IN HEIGHT

EXISTING ROOF MEMBRANENOT TO BE DISTURBED

EXISTING PAVER SYSTEM(NO WORK)

NEW 3/8" STEEL BEAM

INTERIOR EXTERIORGREENHOUSE

EXISTING PARAPET FLASHING CAP TO REMAIN

NEW PLUMBING RUN ABOVESLAB TO EXISTING RISERCONCEALED BENEATH STEP

SOPREMA WATERPROOFING MEMBRANE(COLOR TO BE WHITE)

6-1/2" R-30 SIP PANEL

POLYGAL "THERMOGAL"THERMALLY INSULATEDSTRUCTURAL POLYCARBONATEPANEL (0.31 U VALUE)

NEW SKYLINE TERRACEDOOR (OUTSWING)

3/8" STEEL BEAM

LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERS WITH

REINFORCEMENT FLEECE IN BETWEEN

A-5033

A-5034

A-5035

A-5032

A-5031

A-5054

TYP

OPEN

EX

IST

ING

OP

EN

ING

EXTENT OF EXISTING GREENHOUSE TO BE REMOVED

SILL FLASHING END DAMAT WALL BEYOND (TYP)

HSS 5X5X1/2 COLUMN INWALL BEYOND

ALUMINUM STOREFRONT SYSTEM

GRACE VYCOR SILL FLASHING

GRACE VYCOR-NER END DAMSILL FLASHING BEYOND

BASF SONOLASTIC 150 EXTERIORCAULK (COLOR TO MATCH EXTERIOR

FINISHES PENDING BOARD APPROVAL)

EXTERIOR SHEATHING

SOLARBAN 60 LOW E INSULATED GLASS

R7.5 CONTINUOUS RIGID INSULATION

ALUMINUM SILL PAN

STUCCO EXTERIOR FINISH

R13 BATT INSULATION

CEMENT BACKERBOARD

LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERS WITH

REINFORCEMENT FLEECE IN BETWEEN

3/8" STONE TILE

UNMODIFIED THINSET MORTER

5/8" PLYWOOD SUBFLOOR

EXISTING 2" RIGIDINSULATION

EXISTING ROOFASSEMBLY

EXISTING SLEEPERJOISTS

WATERPROOFSEALANT

1/8" THICK WOODFILLER

EXISTING CMU KNEE WALLMODIFIED IN HEIGHT

EXISTING PAVER SYSTEM(NO WORK)

P.T. WOOD BLOCKING

PAN FLASHINGWITH DRIP EDGE

3/8" BACKER RODAND CAULK

QT SCU PERIMETER ISOLATION STRIP

UV BLOCKING WINDOW FILM

5/8" GYPSUMWALL BOARD

SOLID WOOD SILL

SOLID WOOD TRIM

5/8" PLYWOOD

HSS 3x1-1/2x3/8

3/8" STEEL BEAM

3/8" STEEL TABWELDED TO BEAM

6-1/2" R30 SIPS PANEL

ALUMINUM STOREFRONT SYSTEM

ALUMINUM STOREFRONT SYSTEM

BASF SONOLASTIC 150 EXTERIOR CAULK(COLOR TO MATCH EXTERIOR FINISHES

PENDING BOARD APPROVAL)

ALUMINUM SILL PAN

1" THICK AZEK TRIM

BASF SONOLASTIC 150 EXTERIORCAULK (COLOR TO MATCH EXTERIOR

FINISHES PENDING BOARD APPROVAL)

5/8" PLYWOOD

GRACE VYCOR-NER END DAMSILL FLASHING BEYOND

SOLARBAN 60 LOW E INSULATED GLASS

UV BLOCKING WINDOW FILM

BASF SONOLASTIC 150 EXTERIOR CAULK(COLOR TO MATCH EXTERIOR FINISHES

PENDING BOARD APPROVAL)

1" THICK AZEK FACIA3/4" MDF NOTCHEDAROUND STEEL TAB

WHITE SOPREMAWATERPROOF MEMBRANE

COIL STOCK FLASHING WITH DRIP EDGE(MIN 0.05 GAUGE)

EXTERIOR GREEN-HOUSE

A

A

A

BEAM

BEAM

ALUMINUM STOREFRONT SYSTEM

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

As indicated

A-302

GREENHOUSE SECTIONS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

No. Description Date

1 1/2" = 1'-0"1 GREENHOUSE SECTION

3" = 1'-0"2 GREENHOUSE WEST WALL F.H. SECTION

Page 15: Elam Pricing Full Set 4.3.15

A-5012

TYP

12

13

14

15

16

17

A-5022

1

A-502

TYP

L-P1

L-P1

L-P1

SKYLIGHT OPENING

1

A-501

TYP

1

2

3

4

5

6

7

8

9

10

11

ROPE LIGHTL-RL1

A-5058

3/16"x1/4" STEELBAR STOCK (TYP)

1/2"x1-1/2" STEELBAR STOCKHANDRAIL

4

A-303

2

A-501

1

A-501

TYP

1 2 3 4 5 6 7

8

10

9

11

12

13

151617 14

UP

1

A-502

TYP

2

A-502

3

A-303

FF-6(TYP)

CW-1

EXISTING W8 x 13

NEW DOUBLE JOIST

NEW DOUBLE JOIST

EXISTING W8 x 13

EXISTING W8 x 13

EX

IST

ING

W8

x 13

4

A-303

1

A-501

2

A-501

TYP

1

2

3

4

5

6

7

8

1 3/

4"3'

- 1

1 1/

4"2'

- 0

"1'

- 6

"1

3/4"

1' -

2"

1' -

0"

1' -

0"

1' -

0"

2 1/

4"

1' -

8"

ROPE LIGHTL-RL1

1

A-506

2' - 11 1/4"2' - 11"

A-5058

SIM

GL-1

4

A-506

T.O. GLASS SHELF

T.O. GLASS SHELF

T.O. GLASS SHELF

T.O. GLASS SHELF

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

1" = 1'-0"

A-303

STAIRWELL PLANS & SECTIONS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015 1" = 1'-0"4 STAIRWELL SECTION LOOKING SOUTH

No. Description Date

1" = 1'-0"1

Penthouse F - 36th Floor - Main LevelStairwell Enlarged Plan

1" = 1'-0"2 ROOF FRAMING ABOVE STAIRWELL

1" = 1'-0"3 STAIRWELL SECTION LOOKING NORTH

Page 16: Elam Pricing Full Set 4.3.15

SELF TAPPING MACHINE SCREWS

BOTTOM OF EXISTING CONCRETE ROOF SLAB

1/2" x 3/16" STEEL SUPPORT TABS

8" x 2" 10 GAUGE UNPUNCHED COLD FORM JOIST (TYP)

5/8" EXPANSION BOLT (BASE PLATE ANDBOLT CONCEALED BEHIND FINISHED GWB)

EXISTING WALL ASSEMBLY

8"

BUILT-UP SOLID WOOD STAIR TREAD3'-3" WIDE (VERIFY IN FIELD)

1 1/

4"3

1/2"

1 1/

4"

SP

LIC

E6"

5/8" TYPE X FIRE RATED GYPSUM WALL BOARD

PLASTIC J-BEAD

1/2" x 3/16" STEEL BARSTOCK WITH BRASS FINISH

WELD (TYP)

1" x 1" x 1/8" STEEL TUBE WELDED TO PLATE

1/2" GYPSUM WALL BOARDWITH PLASTER SKIM COAT

3" x 11" x 1/8" THICK STEEL PLATEFASTENED TO WALL

COUNTERSUNK SQUAREDRIVE BOLTS (TYP)

1/2" x 3/16" STEEL BARSTOCK WITH BRASS FINISH

1/2" x 3/16" STEEL BARSTOCK WITH BRASS FINISH

3/4" 3 1/4" 3 1/4" 3/4"WELDED CONNECTION(FILED DOWN FORSMOOTH FINISH)

5/8" GYPSUM WALL BOARD ENCLOSURE

EXISTING WALL ASSEMBLY

OPEN TO SKYLIGHT ABOVEEXISTING SKYLIGHTWALL ASSEMBLY

BRIDGE JOISTS WITHSTEEL STRAP @ 16" O.C.

SOLID FIRE TREATED WOODBLOCKING BETWEEN HEAVYGAUGE JOISTS

EXISTING CONCRETE ROOF SLAB

EXISTING W8 x 13

6" S

PLI

CE

1/2" x 3/16" STEELSUPPORT TABS

(2) 8" x 2" 10 GAUGE UNPUNCHEDCOLD FORM JOIST (TYP)

5/8" EXPANSION BOLT (BASEPLATE AND BOLT CONCEALEDBEHIND FINISHED GWB)

1/2" x 3/16" STEELBAR STOCK (TYP)

1 1/

4"3

1/2"

1 1/

4"

1" x 1" x 1/8" STEEL TUBE (2 PER TREAD)

ST

AIR

TR

EA

D2

1/2"

TH

ICK

MA

XIM

UM

OP

EN

ING

3"7 51

/128

"

1/2" x 3/16" STEELBAR STOCK (TYP)

8 3/4"

COUNTERSUNK SQUAREDRIVE BOLTS (TYP)

3" x 11" x 1/8" STEELPLATE BEYOND

3" x 11" x 1/8" STEELPLATE BEYOND

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

6" = 1'-0"

A-501

STAIR DETAILS I

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

No. Description Date

6" = 1'-0"1 STAIR TREAD SUPPORT DETAIL 1

6" = 1'-0"2 STAIR TREAD SUPPORT DETAIL 2

Page 17: Elam Pricing Full Set 4.3.15

SELF TAPPING MACHINE SCREWS

BOTTOM OF EXISTING CONCRETE ROOF SLAB

1/2" x 3/16" STEEL SUPPORT TABS

8" x 2" 10 GAUGE UNPUNCHED COLD FORM JOIST (TYP)

5/8" EXPANSION BOLT (BASE PLATE ANDBOLT CONCEALED BEHIND FINISHED GWB)

EXISTING WALL ASSEMBLY

8"

BUILT-UP SOLID WOOD STAIR TREAD3'-3" WIDE (VERIFY IN FIELD)

ST

AIR

TR

EA

D2

1/2"

TH

ICK

1 1/

4"3

1/2"

1 1/

4"

SP

LIC

E6"

5/8" TYPE X FIRE RATED GYPSUM WALL BOARD

PLASTIC J-BEAD

1/2" x 3/16" STEEL BAR STOCKWITH BRASS FINISH

WELD (TYP)

1" x 1" x 1/8" STEEL TUBE

1/2" GYPSUM WALL BOARDWITH PLASTER SKIM COAT

COUNTERSUNK SQUAREDRIVE BOLTS (TYP)

1/2" x 3/16" STEEL BARSTOCK WITH BRASS FINISH

1/2" x 3/16" STEEL BARSTOCK WITH BRASS FINISH

3/4" 3 1/4" 3 1/4" 3/4"WELDED CONNECTION(FILED DOWN FOR SMOOTH FINISH)

1/2" x 3/16" STEEL BAR STOCKWITH BRASS FINISH

1/2" x 3/16" STEEL BAR STOCK WEB

1/2" x 3/16" STEEL BAR STOCKFASTENED TO SIDE OF 2NDFLOOR SLAB

1/2"

1"1/

2"6"

WE

BD

IST

AN

CE

VA

RIE

S

1" x 1" x 1/8" STEEL TUBE

1/2" x 3/16" STEELBAR STOCK (TYP)

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

6" = 1'-0"

A-502

STAIR DETAILS II

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

No. Description Date

6" = 1'-0"1

SUSPENDED STAIR TREAD SUPPORTDETAIL

6" = 1'-0"2

LANDING SUPPORT DETAIL AT UPPERLEVEL FLOOR

Page 18: Elam Pricing Full Set 4.3.15

SIP PANEL FASTENED TOSTEEL TAB WELDED TOBEAM WITH THRU BOLT

CONTINUOUS STEEL TABBEYOND WELDED TO BEAM

TO SUPPORT SIP PANEL

(2) 2-1/2" 16 GA STEEL STUD HEADER

WHITE SOPREMA WATERPROOF MEMBRANE

SKYLINE 1700 TERRACE DOOR HEAD

6-1/2" R-30 SIP PANEL

3/4" MDF PANEL(NOTCHED AROUND STEEL TAB)

PL4.5X4.5X3/8 STEEL PLATEWELDED TO HSS8X3X3/8 GIRDER

AND BOLTED TO BEAM

FINISHED WOOD FASCIA

STEEL TAB WELDED TO BEAMAND BOLTED TO CHANNEL

HOMOSOTE

BASF SONOLASTIC 150 CAULK (COLOR TO MATCHEXISTING EXTERIOR FINISH PENDING BOARD APPROVAL)

CONTINUOUS 1/4" STEEL PLATEWELDED TO EAVE BEAM

HSS 8X3X3/8 GIRDER

1" AZECK PANEL

1" X 1" STEEL TUBE

3/4" CDX PLYWOOD

BENT COIL STOCK GUTTERPITCHED TO NORTHWEST END

COIL STOCK FLASHING WITHDRIP EDGE (MIN 0.05 GAUGE)

COIL STOCK FLASHING WITHDRIP EDGE (MIN 0.05 GAUGE)

HILTI KWIK-FLEX SELF-DRILLING SCREWS @16" O.C.

BACKER ROD

WOOD BLOCKING

PLASTIC HORSESHOE SHIM AS REQUIREDTO LEVEL/SQUARE NANAWALL SYSTEM

WOOD BLOCKING

EAVE BEAM WELDED TO HSS 8X3X3/8

HSS 5X5X1/2 COLUMN IN WALL BEYOND

WOOD NAILER GLUED TO GIRDER

1/2" AZEK PANEL

EXISTING PAVER SYSTEM (NO WORK)

BASF SONOLASTIC 150 EXTERIOR CAULK(COLOR TO MATCH EXISTING EXTERIORFINISH PENDING BOARD APPROVAL)

CEMENT BACKERBOARD

LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERS WITH

REINFORCEMENT FLEECE IN BETWEEN

3/8" THICK FLOOR TILE

FLEXIBLE WATERPROOFACOUSTICAL SEALANT

QT SCU PERIMETER ISOLATION STRIP

UNMODIFIED THIN SET MORTER

BACKER ROD

WOOD BLOCKING

EXISTING CMU KNEE WALLMODIFIED IN HEIGHT

NEW PAN FLASHING WITH DRIP EDGE

HILTI KWIK-FLEX SELF-DRILLING SCREWS @16" O.C.

PLASTIC HORSESHOE SHIM AS REQUIREDTO LEVEL/SQUARE NANAWALL SYSTEM

5/8" PLYWOOD SUBFLOOR

EXISTING 2" RIGIDINSULATION

SKYLINE 1700 TERRACE DOOR SILL

EXISTING ROOF ASSEMBLY

EXISTING SLEEPER JOISTS

BASF SONOLASTIC 150 EXTERIOR CAULK(COLOR TO MATCH EXISTING EXTERIORFINISH PENDING BOARD APPROVAL)

HSS 5X5X1/2 COLUMN IN WALL BEYOND

NEW FLASHING END DAM AT WALLBEYOND (TYP. BOTH SIDES)

EXISTING WALL ASSEMBLY

C8X13.7 STEEL CHANNEL BOLTEDWITH EPOXY TO EXISTING MASONRY

3/8" STEEL BEAM

1-1/2" METAL FRAMING BOLTED WITHEXPOXY BACK TO EXISTING MASONRY

5/8" GYPSUM WALL BOARD

5/8" GYPSUM WALL BOARD

STEEL PL4.5X4.5X3/8 WELDED TOC8X13.7 CHANNEL AND BOLTED TO BEAM

ALUMINUM END CAP

POLYGAL 'THERMALGAL' PANEL

CAULK

1-1/2" METAL FRAMINGBOLTED WITH EXPOXY BACKTO EXISTING MASONRY

5/8" GYPSUM WALL BOARD

PLASTIC J-BEAD

WOOD BLOCKING

EXISTING PARAPET CAP FLASHING

EXISTING WALL ASSEMBLY

3/4" MDF PANEL

ALUMINUM CAP PROFILE

GLAZING EPDM

POLYGAL FLASHING CAP

WHITE SOPREMAWATERPROOF MEMBRANE

6-1/2" R-30 SIP PANEL

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

6" = 1'-0"

A-503

GREENHOUSE DETAILS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

6" = 1'-0"2 NANAWALL HEAD/GIRDER DETAIL

No. Description Date

6" = 1'-0"1

GREENHOUSE FLOOR DETAIL @NANAWALL RAISED SILL

6" = 1'-0"3 BEAM SEAT DETAIL

6" = 1'-0"4 UPPER POLYGAL PANEL SECTION

6" = 1'-0"5 LOWER POLYGAL SECTION

Page 19: Elam Pricing Full Set 4.3.15

EXISTING BUILT-UPROOF MEMBRANCE

NOT TO BE DISTURBEDEXISTING ROOF & SKYLIGHTCURB ASSEMBLY

1/2" GYPSUM WALL BOARD

NEW VELUX FIXED CM DOMECURB MOUNTED SKYLIGHT 0.030" ACRYLIC INTERLAYER

WHITE LAMINATED ACRYLIC OUTER DOME

VERIFY DIMENSIONS IN FIELDEXISTING OUTBOUND CURB

A-5042

NEW SAFETY RAIL SOURCESAFETY ROOF SCREEN

FASTENED TO SKYLIGHT FRAMEWITH STEEL CLIPS 12" O.C.

(STAIRWELL SKYLIGHT ONLY)

NEW 1/2" GYPSUM WALL BOARD

NEW CURB FLASHING

CONDENSATE CONTROLGUTTER WITH WEEP HOLES

ALUMINUM SKYLIGHT FRAME

THERMAL BARRIER

EXISTING ROOF FLASHINGDO NOT DISTURB

NEW SAFETY RAIL SOURCESAFETY ROOF SCREEN

FASTENED TO SKYLIGHT FRAMEWITH STEEL CLIPS 12" O.C.

(STAIRWELL SKYLIGHT ONLY)

I. ANY ALTERATION TO ROOFING DURING REMOVAL AND CONSTRUCTION MUST BE PERFORMED BYTHE BUILDING'S ROOFING CONTRACTOR (YORK RESTORATION CORP.) TO MAINTAIN WARRANTY.

GENERAL ROOF NOTES

NEW TYPE X FIRE RATED 5/8" GYPSUM WALLBOARD. TAPE AND FINISH TO MATCH CEILING.

NEW 3-5/8" 20ga METAL RUNNER

(VE

RIF

Y IN

FIE

LD)

EX

IST

ING

RO

OF

ST

RU

CT

UR

E

EXISTING FIRE RATED 5/8"GYPSUM WALL BOARD(VERIFY IN FIELD)

EXISTING FIRE RATED 5/8"GYPSUM WALL BOARD(VERIFY IN FIELD)

NEW 3-5/8" 20ga METAL STUDS @12" O.C.

OVERLAP2" MINIMUM

(TYP ALL AROUND)

EXTEND WATERPROOFING3" PAST OPENING

(VE

RIF

Y IN

FIE

LD)

EX

IST

ING

RO

OF

ST

RU

CT

UR

E

(THICKNESS = EXISTING # OF PLYS + 1 PLY OVERLAP)NEW BUILT-UP ROOFING

FASTEN FRAMING TO EXISTING STRUCTUREWITH SELF TAPING SCREWS (TYP ALL AROUND)

NEW R-38 BATT INSULATION

(VERIFY DIMENSIONS IN FIELD)EXISTING ROOF OPENING

OVERLAP2" MINIMUM

(TYP ALL AROUND)

EXTEND WATERPROOFING3" PAST OPENING

NEW (2) LAYERS OF 3/4" FIRE TREATED CDX PLYWOOD

NEW WATERPROOFING MEMBRANE

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

As indicated

A-504

ROOF DETAILS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

No. Description Date

3" = 1'-0"1 SKYLIGHT SECTION

6" = 1'-0"2 SKYLIGHT CURB DETAIL

6" = 1'-0"3 ROOF PATCH DETAIL

Page 20: Elam Pricing Full Set 4.3.15

3/4" HARDWOOD FINISH FLOORING

5/8" FLOATING FIRE TREATED PLYWOODSUB-FLOOR APPLIES PERPENDICULAR

TO ACOUSTICAL UNDERLAYMENT

QUIETDOWN MAX (4MM) ACOUSTICUNDERLAY WITH TAPED SEAMS

NOTE: FINISHED WOOD FASTNERESMUST NOT PENETRATE ACOUSTICALUNDERLAYMENT IN ANY WAY

1/8"

MAINTAIN 1/8" GAP BETWEENFLOOR ASSEMBLY AND WALL

HOLD 1/2" BASE TRIM 1/8" CLEARABOVE FINISHED FLOOR

ACOUSTICAL SEALANT ATFLOOR PERIMETER

EXISTING SLAB

WALL ASSEMBLY

ACOUSTICAL SEALANT

3/8" PORCELAIN TILE

LEAD SHOWER PAN

LIQUID LATICRETEWATERPROOFINGMEMBRANE # 9235

MUD SET

EXISTING FLOORASSEMBLY

NICKLE / BRONZEADJUSTABLESTRAINER

3/16" PORCELAIN TILE

5/8" BACKERBOARD

LOOSE GRAVEL OR CRUSHED TILE AT WEEP HOLES

FLASHING CLAMP WITH WEEP HOLES

THREADED, CAULKED OR NO-HUB CONNECTION

HE

IGH

T O

F L

EA

DP

AN

AB

OV

EF

INIS

HE

D S

HO

WE

RF

LOO

R

EXISTING WALLASSEMBLY

CONTINUOUS WATERPROOFINGMEMBRANE TO 6" ABOVE SHOWER HEAD

FINISHED FLOORASSEMBLY

CURB6"

EXISTING FLOOR SLAB

EXISTING WALL ASSEMBLY

CEMENT BACKERBOARD

LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERSWITH REINFORCEMENT FLEECE INBETWEEN

3/8" THICK FLOOR TILE

HONEYWELL RADIANTFLOOR WARMING SYSTEM

MIN

IMU

M A

BO

VE

FIN

ISH

FLO

OR

EX

TE

ND

WA

TE

RP

RO

OF

ING

ME

MB

RA

NE

6"

FLEXIBLE WATERPROOFACOUSTICAL SEALANT

QT scu PERIMETER ISOLATION STRIP

3/16" THICK WALL TILE

UNMODIFIED THIN SET MORTER

LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERSWITH REINFORCEMENT FLEECE INBETWEEN

SCHLUTER DITRA MEMBRANE

CEMENT BACKERBOARD

QUIETDOWN MAX (4MM)ACOUSTIC UNDERLAYWITH TAPED SEAMS

UNMODIFIED THIN SET MORTAR

3/8" PORCELAIN TILE

6 GAUGE LEAD SHOWER PAN

LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERS WITHREINFORCEMENT FLEECE IN BETWEEN

MUD SET

EXISTING FLOOR SLAB

LINEAR DRAIN WITH REMOVABLESTAINLESS STEEL PERFORATED GRATE

3/16" PORCELAIN WALL TILE

5/8" BACKERBOARD

HE

IGH

T O

F L

EA

D P

AN

AB

OV

EF

INIS

HE

D S

HO

WE

R F

LOO

R

EXISTING WALLASSEMBLY

LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERS WITHREINFORCEMENT FLEECE IN BETWEEN.TERMINATE 6" ABOVE SHOWER HEAD.

3/8" PORCELAIN TILE CURB

6"

FLASHING CLAMP WITH WEEP HOLES

THREADED, CAULKED, OR NO-HUB CONNECTION

± 3 1/2"

WA

LL O

PE

NIN

G4"

MIN

IMU

M

EXISTING GWB

5/8" BACKERBOARD

3/4" PLYWOOD

2" x 6" WOODFLOOR JOISTS@12" O.C. (TYP)

2" PVC SANITARY P-TRAP

UNMODIFIED THIN SET MORTAR

6 GAUGE LEAD SHOWER PAN

5/8" BACKERBOARD

WOOD BLOCKING

UNMODIFIED THIN SET MORTAR

3/16" PORCELAIN WALL TILE

A-5053SIM

EXISTING FLOOR SLAB

CEMENT BACKERBOARD

LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERSWITH REINFORCEMENT FLEECE INBETWEEN

3/8" FLOOR TILE (FF-1/FF-2)WET LOCATIONDRY LOCATION..

HONEYWELL RADIANTFLOOR WARMING SYSTEM

SCHLUTER DITRA MEMBRANE

QUIETDOWN MAX (4MM)ACOUSTIC UNDERLAYWITH TAPED SEAMS

UNMODIFIED THIN SET MORTER

1/8"

MIN

.

EXISTING FLOOR SLAB

CEMENT BACKERBOARD

LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERSWITH REINFORCEMENT FLEECE INBETWEEN

3/8" FLOOR TILE (FF-1)WET LOCATIONDRY LOCATION

..

SCHLUTER DITRA MEMBRANE

UNMODIFIED THIN SET MORTER

QUIETDOWN MAX (4MM)ACOUSTIC UNDERLAYWITH TAPED SEAMS

EXISTING FLOOR SLAB

CEMENT BACKERBOARD

LATICRETE 9235 WATERPROOFINGMEMBRANE APPLIED IN (2) LAYERSWITH REINFORCEMENT FLEECE INBETWEEN

3/8" FLOOR TILE

CORIAN SADDLE (GLACIER WHITE)

3/4" HARDWOODFLOORING

ACOUSTICAL SEALANTAT FLOOR PERIMETER

HONEYWELL RADIANTFLOOR WARMING SYSTEM

SCHLUTER DITRA MEMBRANE

QUIETDOWN MAX (4MM)ACOUSTIC UNDERLAYWITH TAPED SEAMS

UNMODIFIED THIN SET MORTER

5/8" PLYWOODSUBFLOORING

QT scu ISOLATION STRIP

1/8"

MIN

.

WET LOCATIONDRY LOCATION..

ROPE LIGHT L-RL1

3/4" PLYWOOD

3/4" SOLIDWOOD FINISH

3/4" SOLIDWOOD FINISH

2X6 WOODFRAMING @16"O.C.

EXISTING MAIN LEVELFLOOR ASSEMBLY

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

As indicated

A-505

FLOOR DETAILS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

6" = 1'-0"5 WOOD FLOOR SOUNDPROOFING DETAIL

3" = 1'-0"6 SHOWER INSTALLATION DETAIL

6" = 1'-0"3

FLOOR WATERPROOFING DETAIL @WALL

No. Description Date

6" = 1'-0"7 RAISED SHOWER INSTALLATION DETAIL

6" = 1'-0"1

FLOOR WATERPROOFING DETAIL @THRESHOLD (MAIN LEVEL)

6" = 1'-0"2 FLOOR WATERPROOFING DETAIL

6" = 1'-0"4

FLOOR WATERPROOFING DETAIL @THRESHOLD (UPPER LEVEL)

6" = 1'-0"8 STAIR PLATFORM EDGE DETAIL

Page 21: Elam Pricing Full Set 4.3.15

ROPE LIGHTL-RL1

2"

A-5011

SIM

A-5062

A-5063

STAIRWELL KITCHEN

A-5058SIM

4

A-506

SIM

1/2" SOLID WOOD

(2) LAYERS 3/4" PLYWOOD

METAL LAMINATE

METAL LAMINATE1/2" SOLID GLASS SHELF

1/4" SOLID GLASS BACK PANEL1/4" SOLID GLASSCABINET DOORS

ROPE LIGHT L-RL2

3 1/2" 1" 3 1/2"

STAIRWELL KITCHEN

ROUTE OUT RACEWAYFOR BX WIRE

1/2" SOLID GLASS SHELF(ADJUSTABLE HEIGHT)

1/4" SOLID GLASSCABINET DOORS

1/4" SOLID GLASSBACK PANEL

5/8" GYPSUM BOARD

Z CLIPS 16" O.C.

1/2" MEDIUM DENSITYFIBERBOARD

3/4" PLYWOOD

3-5/8" METAL TRACK

3-5/8" METALSTUDS @16" O.C.

STAIRWELL KITCHEN

1/2" SOLID WOOD

(2) LAYERS 3/4" PLYWOOD

1/8" METAL LAMINATE

METAL LAMINATE

ROPE LIGHT L-RL2

1 3/4" 4" 1 3/4"

3"

EXISTING WALL ASSEMBLY

1/4" SOLID GLASS BACK PANEL

1/2" SOLID GLASS SHELF

METAL LAMINATE

(2) LAYERS 3/4" PLYWOOD

1/2" SOLID WOOD

1/2" THICK GLASS SHELF

1/2" SOLID WOOD

UPHOLSTERED HEADBOARD

5

A-506

1" 11" 2' - 2" 2' - 2" 2' - 2" 11" 1"

1"

1/4"

10"

1/4"

10"

1/4"

10"

1/4"1"3"

2' -

9"

3" 8' - 0" 3"

5

A-506

CW-1

DRAWERDRAWER

DRAWER

DRAWER

MATRESS BY OWNER

BED FRAME BY OWNER

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

As indicated

A-506

CASEWORK DETAILS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

No. Description Date

1" = 1'-0"1

KITCHEN/STAIRWELL CUSTOMCASEWORK SECTION

6" = 1'-0"2

KITCHEN/STAIRWELL CUSTOMCASEWORK SECTION - Callout 1

3" = 1'-0"3

KITCHEN/STAIRWELL CUSTOMCASEWORK SECTION - Callout 2

3" = 1'-0"4

KITCHEN/STAIRWELL CUSTOMCASEWORK SIDE SECTION DETAIL

1" = 1'-0"6 Master Bed Front Elevation

1" = 1'-0"7 Master Bed Back Elevation

3" = 1'-0"5 Master Bedroom Custom Casework Section

Page 22: Elam Pricing Full Set 4.3.15

J-BEAD

1/4" GYPSUM WALL BOARD

PLASTER SKIM COAT

QUICKSET FASTENERS(ALTERNATING ANGLES@10" O.C.)

EXISTING FLOOR SLAB ABOVE

3-5/8" 22 GA METAL TRACK

3-5/8" 22 GA METAL STUDS

3-5/8" 22 GA METAL TRACK

1-1/2" CORSE THREADCOUNTERSUNKSCREWS @10" O.C.

FIRE TREATED WOODBLOCKING BETWEEN STUDS

RECESSED LIGHTING FIXTUREL-R1

SOLID WOOD MOLDING

1/2" MDF PAINTED WHITE

U/S OF EXISTING UPPERLEVEL FLOOR SLAB

1/4" REVEAL PAINED BLACK

1/2" PLYWOOD

EXISTING EXTERIOR WALL

SHADE

ROLER SHADE COVER PANEL

AUTOMATIC ROLER SHADE

SOLID WOOD MOLDING

5/8" GYPSUM BOARD PAINTED

ROPE LIGHT L-R2

3-5/8" 22GA METAL RUNNERS

FIRE TREATED WOODBLOCKING BETWEEN STUDS

PAINTED GYPSUM BOARD

QUICKSET FASTENERS @10"O.C. (ALTERNATING ANGLES)

3-5/8" 22GA METAL STUDS

U/S OF EXISTING EXPOSEDCONCRETE FLOOR SLAB

RECESSED LIGHTINGFIXTURE L-R2

3" 3" DISTANCE VARIES

SCHEDULED ROLLER SHADE POCKET OPENING

1/4" REVEAL PAINTED BLACK

CLEAR "U" CHANNEL

1/4" REVEAL PAINTED BLACK

DISTANCE VARIES

FIRE TREATED WOODBLOCKING BETWEEN STUDS

SOLID WOOD MOLDING

5/8" GYPSUM BOARD PAINTED

ROPE LIGHT L-RL2

1/2" MDF PAINTED WHITE

QUICKSET FASTENERS(ALTERNATING ANGLES@10" O.C.)

3-5/8" 22 GA METAL TRACK

3-5/8" 22 GA METAL STUDS

3-5/8" 22 GA METAL TRACK

FIRE TREATED WOODBLOCKING BETWEENMETAL STUDS

RECESSED LIGHTING FIXTUREL-R2U/S OF EXISTING UPPER

LEVEL FLOOR SLAB

QUICKSET FASTENERS @10" O.C.(ALTERNATING ANGLES)

3-5/8" 22 GA METAL TRACK

3-5/8" 22 GA METAL STUDS

3-5/8" 22 GA METAL TRACK

FIRE TREATED WOOD BLOCKINGBETWEEN METAL STUDS

FIRE TREATED WOODBLOCKING

RECESSED LIGHTINGFIXTURE L-R5

3/4" SOLID WOOD TRIM

3/4" SOLID WOOD TRIM

1/4" REVEAL PAINTED BLACK

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

6" = 1'-0"

A-507

CEILING DETAILS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

No. Description Date

6" = 1'-0"2 TYPICAL DROP CEILING DETAIL

6" = 1'-0"1 SHADE POCKET DETAIL

6" = 1'-0"3 TYPICAL SOFFIT DETAIL

6" = 1'-0"4

MASTER BEDROOM DROP CEILINGTYPICAL DETAIL

Page 23: Elam Pricing Full Set 4.3.15

PLUMBING FIXTURE SCHEDULEDESIGNATION DESCRIPTION MANUFACTURER LOCATION(S)SERIES

PL-1

INTEGRATED STONE SINK WITH OVERFLOW

PL-2

PL-5 N/A

PL-4 S-AG 38

WALL HUNG TOILET WITH SEAT 1ST FLR: POWDER RM, BATHROOM 2ND FLR: MASTER BATHROOM

SHOWER HEAD

PL-6

N/APROVIDED BY OWNER 1ST FLR: KITCHEN COUNTERTOPPL-7

N/APL-8

N/A

LINEAR SHOWER DRAIN

PL-3

PROVIDED BY OWNER

PROVIDED BY OWNER

SITE BUILT

GEBERIT

TBD

INFINITY

DURAVIT

DUOFIX 111.728.00.1

STARCK #220109

TBD

CNT

WALL HUNG TOILET CARRIER WITH ACTIVATOR

UNDERMOUNT STAINLESS STEEL KITCHEN SINK

SINGLE HOLE DECK MOUNTED MASTER LAV

UNDERMOUNT STAINLESS STEEL BAR SINKPL-9

N/APROVIDED BY OWNERFAUCETPL-10

N/APROVIDED BY OWNERFAUCETPL-11

N/APROVIDED BY OWNERFAUCET

2ND FLR: MASTER BATHROOM

2ND FLR: GREENHOUSE

3

3

2

2

1

1

1

1

2

1

1

1ST FLR: POWDER RM, BATHROOM 2ND FLR: MASTER BATHROOM

1ST FLR: POWDER RM

1ST FLR: BATHROOM 2ND FLR: MASTER BATHROOM

1ST FLR: BATHROOM 2ND FLR: MASTER BATHROOM

1ST FLR: POWDER RM, BATHROOM

1ST FLR: KITCHEN

2ND FLR: MASTER BATHROOMPL-12

INTEGRATED CORIAN SINK N/ASITE BUILT1 1ST FLR: BATHROOM VANITY

N/APROVIDED BY OWNERFAUCET1 2ND FLR: GREENHOUSEPL-13

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

1" = 1'-0"

A-600

FIXTURE, APPLIANCE, & DOORSCHEDULES

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

No. Description Date

LIGHTING FIXTURE SCHEDULEDesig. Cnt Description Housing / Trim Lamp Manufacturer Product ID Location(s)L-P1 1 PENDANT MOUNTED (OWNER PROVIDED) NA INCANDESCENT 1ST FLR: DININGL-P2 3 PENDANT MOUNTED (OWNER PROVIDED) NA T5 Delray Lighting 6311 2MD FLR: STAIRWELLL-R1 23 LOW VOLTAGE HALOGEN TRIMLESS HALOGEN (12OV, 277V, OR 347V) USAI 9004-10-C-FL100-120 1ST FLR: FOYER/LIVING/DINING SOFFITSL-R2 17 LOW VOLTAGE HALOGEN 4" LOW VOLTAGE REMODEL HOUSING MR16 (12V/50W) WAC LIGHTING HR-8401E 1ST FLR: LIVING/DINING & KITCHEN DROP CEILINGL-R3 4 1" LEDme MINI RECESSED ADJUSTABLE SPOT NA / LOW PROFILE TRIM WARM/NEUTRAL LED (3W) WAC LIGHTING HR-LED272R 1ST FLR: POWDER ROOM CEILINGL-R4 4 4" LEDme NEW CONSTRUCTION HOUSING / SHOWER TRIM 6 x WARM/NEUTRAL LED (3W) WAC LIGHTING HR-LED418-N 1ST FLR: BATHROOM SHOWER CEILING 2ND FLR: MASTER BATHROOM SHOWER CEILINGL-R5 12 3.5" TESLA LED NA / DOWNLIGHT TRIM LUXEON S MULTI-CHIP LED (18W) WAC LIGHTING HR-3LED-T718 2ND FLR: STAIRWELL CEILING, HALL CEILING, MASTER BEDROOM DROP CEILINGL-R6 12 1" LEDME MINI RECESSED ADJUSTABLE SPOT NA / LOW PROFILE TRIM WARM/NEUTRAL LED (3W) WAC LIGHTING HR-LED272R 1ST FLR: BEDROOM CLOSET CLG 2ND FLR: W/D CLG, ELEC CLOSET CLG, M. BEDROOM CLOSET CLGL-S1 3 SURFACE MOUNTED (OWNER PROVIDED) 2ND FLR: MASTER BEDROOM DROP CEILINGL-S2 7 SURFACE MOUNTED (OWNER PROVIDED) 2ND FLR: GREENHOUSE BAY CEILINGSL-TL1 1 14' LED TRACK LIGHTING (OWNER PROVIDED) 2ND FLR: MASTER BEDROOM CEILING (WEST)

L-WM1 2 WALL MOUNTED (OWNER PROVIDED) 1ST FLR: POWDER ROOM (BEHIND MIRROR)L-WM2 2 WALL MOUNTED (OWNER PROVIDED) 1ST FLR: BATHROOM (ABOVE MIRROR)L-WM3 1 WALL MOUNTED (OWNER PROVIDED) 1ST FLR STAIRWELL (WALL MOUNTED ABOVE STAIR PLATFORM)L-WM4 1 WALL MOUNTED (OWNER PROVIDED) 2ND FLR: MASTER BATHROOM (WALL MOUNTED W/ MIRROR SURROUND)L-WM5 1 WALL MOUNTED (OWNER PROVIDED) 2ND FLR: MASTER BEDROOM (WALL MOUNTED)L-WM6 2 WALL MOUNTED (OWNER PROVIDED) 2ND FLR: MASTER BEDROOM (WALL MOUNTED)

APPLIANCE SCHEDULEDesig. Description Manufacturer Model Location

AP-1 30" ALL GAS RANGE MIELE HR1124 1ST FLR: KITCHEN RANGE WALLAP-2 30" BUILT-IN WALL CABINET HOOD MIELE DA3480 1ST FLR: KITCHEN RANGE WALLAP-3 30" INTEGRATED O&U REFRIGERATOR/FREEZER SUB ZERO IT-30CI 1ST FLR: KITCHEN RANGE WALLAP-4 24" UNDER COUNTER MICROWAVE W/DRAWER JENN AIR JMD2124WS 1ST FLR: KITCHEN FLOATING BASE CABINETSAP-6 24" UNDER COUNTER WINE STORAGE MIELE KWT4154UG-1 1ST FLR: FOYER/LIVING CUSTOM CASEWORKAP-7 24" COMPACT WASHING MACHINE LG WM1355HW 2ND FLR: W/DAP-8 24" COMPACT ELECTRIC CONDENSING DRYER LG DLEC855W/R 2ND FLR: W/DAP-9 27" INTEGRATED WINE STORAGE SUB ZERO 427RG 2ND FLR: GREENHOUSE CUSTOM CASEWORKAP-10 24" UNDERCOUNTER DISHDRAWER DISHWASHER FISHER & PAYKEL DD24SVT7 2ND FLR: GREENHOUSE CUSTOM CASEWORK

APPLIANCE & FIXTURE NOTESI. GC TO PROVIDE AND INSTALL ALL APPLIANCES LISTED IN SCHEDULE.

II. GC TO PROVIDE ALL SUPPLY AND WASTE PIPING NECESSARY FOR THEINSTALLATION OF ALL PLUMBING FIXTURES AND APPLIANCES AS REQUIRED.

DOOR SCHEDULEMark Description Count Height Width Thickness Finish Frame Type Hardware Location(s)

1 POCKET 1 8' - 0" 2' - 8" 1 1/2" Solid Wood 1ST FLR: POWDER RM2 TOP HUNG SLIDING 1 7' - 10" 4' - 10 1/2" 2" Solid Wood 1ST FLR: BEDROOM3 POCKET 1 8' - 0" 2' - 8" 1 1/2" Solid Wood 1ST FLR: BATHROOM4 TOP HUNG SLIDING 1 7' - 10" 4' - 5 3/4" 2" Solid Wood 2ND FLR: MASTER BEDROOM5 POCKET 1 8' - 0" 2' - 8" 1 1/2" Solid Wood 2ND FLR: MASTER BATHROOM6 SINGLE FLUSH SWING RHR 1 6' - 8" 2' - 6" 2" Solid Wood 2ND FLR: GREENHOUSE7 TEMPERED GLASS OUTSWING 1 7' - 9" 2' - 7" 3/8" Extruded Aluminum Edge 1ST FLR: BATHROOM SHOWER8 TEMPERED GLASS OUTSWING 1 7' - 8" 2' - 11 1/4" 3/8" Extruded Aluminum Edge 2ND FLR: MASTER BATHROOM SHOWER9 SKYLINE 1700 TERRACE OUTSWING 1 7' - 11" 3' - 0" 1 3/4" Hollow Metal 2ND FLR: GREENHOUSE/TERRACE

C1 RECESSED SINGLE FLUSH (RH) 1 6' - 8" 2' - 6" 2" Recessed Wood 1ST FLR: BEDROOM CLOSETC2 RECESSED SINGLE FLUSH (LH) 1 6' - 8" 2' - 4" 1 1/2" Recessed Wood 2ND FLR: WASHER/DRYER CLOSETC3 RECESSED SINGLE FLUSH (RH) 1 6' - 8" 1' - 10" 1 1/2" Recessed Wood 2ND FLR: ELECTRICAL CLOSETC4 CUSTOM DOUBLE WITH GLASS LITES 3 8' - 0" 3' - 10" 2" Solid Wood 2ND FLR: MASTER BEDROOM CLOSET

Page 24: Elam Pricing Full Set 4.3.15

FLOOR FINISH SCHEDULEDESIGNATION SIZE/MATERIAL FINISH MANUFACTURER LOCATION(S)

FF-1 3/8"x12"x24" PORCELAIN FLR TILE MATTE NASCO STONE & TILE

SERIES/COLOR

FUSSION, DARK ANTHRACITE

FF-3

3/8"x6"x24" PORCELAIN FLR TILE MATTE PROVENZAW-AGE, CORTEX NERO

FF-5 3/4" VENEERED PLYWOOD FLOOR SATIN CLEAR TBDEAST INDIAN ROSEWOOD

1ST FLR: FOYER, LIVING, DINING, KITCHEN, BEDROOM, BATHROOM

FF-6 3/4" SOLID WOOD RUBBED MONOCOAT MATTEWALNUT 1ST FLR: STAIR TREADS, KITCHEN CUSTOM CASEWORK

2ND FLR: MASTER BEDROOM, MASTER BATHROOM, GREENHOUSE

2ND FLR: MASTER BATHROOM & SHOWER

FF-2 3/8"x40"x40" PORCELAIN FLR TILE MATTE NASCO STONE & TILEFUSSION, DARK ANTHRACITE 1ST FLR: POWDER RM

FF-4

3/8"x6"x36" PORCELAIN WALL TILE MATTE DALTILEACACIA VALLY, ASH 1ST FLR: BATHROOM SHOWER

TBD

REMARKS

FIELD CUT AS NOTED IN PLAN

WALL FINISH SCHEDULEDESIGNATION SIZE/MATERIAL FINISH MANUFACTURER LOCATION(S)SERIES/COLOR

WF-1

1/2"x36"x144" CORIAN SHEET FACTORY DUPONTSOLID SURFACE, GLACIER WHITE 1ST FLR: BATHROOM 2ND FLR: MASTER BATHROOM

WF-2

3/8"x6"x36" PORCELAIN WALL TILE MATTE DALTILEACACIA VALLY, ASH 1ST FLR: BATHROOM

WC-1 DYED SILK DEGOURNAYDECORATIVE WALL COVERING KOREAN PEONY

P-3 MATTE BENJAMIN MOOREWATER BASED PAINT TBD

P-4 MATTETBD

WF-4 SATIN CLEAR TBD1/2" VENEERED PLYWOOD EAST INDIAN ROSEWOOD 1ST FLR: POWDER RM 2ND FLR: MASTER BATHROOM

1st Flr: TBD 2nd Flr: TBD

MR-1 GLASS TBDWALL MTD MIRROR SURFACE N/A

BENJAMIN MOOREWATER BASED PAINT 1st Flr: TBD 2nd Flr: TBD

WC-2 MATTE DEGOURNAYPAPER WALL COVERING ROYAL RED 1ST FLR: FOYER

1ST FLR: POWDER RM, BATHROOM 2ND FLR: MASTER BATHROOM

3/8"x40"x40" PORCELAIN WALL TILE MATTE NASCO STONE & TILEFUSSION, DARK ANTHRACITE 1ST FLR: POWDER RM

WF-3

P-1 MATTE BENJAMIN MOOREWATER BASED PAINT TBD

P-2 MATTETBD

1st Flr: TBD 2nd Flr: TBD

BENJAMIN MOOREWATER BASED PAINT 1st Flr: TBD 2nd Flr: TBD

REMARKS

PROVIDED BY OWNER1ST FLR: POWDER RM

PROVIDED BY OWNER

PROVIDED (3) SAMPLES

PROVIDED (3) SAMPLES

PROVIDED (3) SAMPLES

PROVIDED (3) SAMPLES

WB-1 MATTETBD TBDWOOD WALL BASE 2nd Flr: GREENHOUSE

WF-5 SATIN CLEAR TBD1/2" VANEERED MDF QUARTER SAWN WALNUT 1ST FLR: FOYER

CASEWORK FINISH SCHEDULEDESIGNATION SIZE/MATERIAL FINISH MANUFACTURER LOCATION(S)SERIES/COLOR

CT-1

3/4"x36"x144" CORIAN SHEET FACTORY DUPONTSOLID SURFACE, GLACIER WHITE 1ST FLR: BATHROOM VANITY C-TOP 2ND FLR: MASTER BATH VANITY C-TOPCT-2

CW-2 GLOSSY TBD

CW-1 LACQUERED TBD 1ST FLR: KITCHEN/STAIRWELL CUSTOM CASEWORK

3/4" SOLID WOOD WALNUT

1-1/8" SOLID GRANITE HONED SMC STONEABSOLUTE BLACK 1ST FLR: KITCHEN COUNTERTOP

3/4" VENEERED MDF DECORATOR WHITE

CW-3 SATIN CLEAR TBD1/4" VENEERED PLYWOOD EAST INDIAN ROSEWOOD 2ND FLR: MASTER BATHROOM VANITY

1ST FLR: KITCHEN BASE CABINETS

SS-1 BRUSHED TBD1/2" STEEL LAMINATED WOOD STAINLESS STEEL 1ST FLR: KITCHEN RANGE, ADJACENT UPPER/LOWER CASEWORK & C-TOP

GL-1 CLEAR TBD1/2" THICK GLASS N/A 1ST FLR: KITCHEN/STAIRWELL CUSTOM WALL HUNG CABINET/SHELVING

1-1/8" SOLID STONE HONED DUPONTJET MIST 1ST FLR: POWDER RM VANITY COUNTERTOPCT-3

REMARKS

EASED EDGE. RECIEVES (2) COATS OF SEALER

RECIEVES (2) COATS OF SEALER

CW-4 SATIN CLEAR TBD1/2" VENEERED MDF QUARTER SAWN WALNUT 1ST FLR: FOYER, BEDROOM SOLID WOOD EDGING

CW-5 SATIN CLEAR TBD1/2" SPRAY LAQUERED MDF TBD 1ST FLR: LIV/DINING & BDRM PTAC ENCLSR 2ND FLR: M.BDRM PTAC ENCLSR

CT-4 3/4"x36"x144" CORIAN SHEET FACTORY DUPONTSOLID SURFACE, TBD 1ST FLR: LIV/DINING & BDRM PTAC ENCLSR 2ND FLR: M.BDRM PTAC ENCLSR

CT-5 3/4" VENEERED MDF FACTORY TBDTBD 1ST FLR: BEDROOM ENTERTAINMENT CENTER COUNTERTOP & OFFICE DESKTOP

CEILING FINISH SCHEDULEDESIGNATION SIZE/MATERIAL FINISH MANUFACTURER LOCATION(S)SERIES/COLOR

CF-1

VENETIAN PLASTER FACTORY DUPONTWHITE 1ST FLR: LIVING/DINING & KITCHEN DRP CLG 2ND FLR: MASTER BED DRP CLG

CF-2

5/8" GYPSUM BOARD MATTE TBDWHITE 1ST FLR: LIVING/DINING, FOYER, & BEDROOM SOFFITS

CF-5

CF-4 SATIN CLEAR TBD1/2" VENEERED PLYWOOD EAST INDIAN ROSEWOOD 1ST FLR: FOYER/LIVING/DINING/KITCHEN SOFFIT COVE

5/8" MOISTURE RESISTANT GWB MATTE TBDWHITE 1ST FLR: BATHROOM, POWDER RM 2ND FLR: MASTER BATHROOM

CF-3

3/8"x6"x36" PORCELAIN TILE MATTE DALTILEACACIA VALLY, ASH 1ST FLR: BATHROOM SHOWER

CF-6 3/4" MEDIUM DENSITY FIBERBOARD MATTE TBDWHITE 2ND FLR: GREENHOUSE BAY CIELINGS

REMARKS

NOTCH AROUND ROOF BEAM FLANGE

MOUNT ON MOISTURE RESISTANT BACKERBOARD

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

1" = 1'-0"

A-601

FINISH SCHEDULES

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

No. Description Date

FINISH NOTESI. GC TO PROVIDE SUBMITTALS FOR ALL FINISHES TO BE APPROVED BYOWNER/ARCHITECT

II. ALL STONE TO RECIEVE (2) COATS SEALER

Page 25: Elam Pricing Full Set 4.3.15

GFI

GF

I

GFI

GF

IG

FI

GF

I

TV

TD

GFI

GF

I

GFI

TV

TD

R

UP

REF.

RANGE

HOODU.C.MICROWAVEGFI

U.C.REF.

GFI GFI

MOTORIZED SHADE(AT CEILING)

MO

TO

RIZ

ED

WIN

DO

WS

HA

DE

(C

EIL

ING

)

U.C.D/W

FCU-1

I

MOTORIZED WINDOWSHADE (CEILING) MOTORIZED WINDOW

SHADE (CEILING)

DN

MOTORIZED SHADE(AT CEILING)

W D

GFI

UP1 Riser

A B

1

I

WP

WP

I

SINGLE WALL MOUNTED RECEPTACLE

SYMBOL DESCRIPTION

ELECTRICAL RECEPTACLE LEGEND

DUPLEX WALL MOUNTED RECEPTACLE

GFI DUPLEX WALL MOUNTED RECEPTACLE

240V WALL MOUNTED RECEPTACLE

CATV WALL MOUNTED RECEPTACLE

TELE/DATA WALL MOUNTED RECEPTACLE

INTERCOM SERVICE

WATERPROOF DUPLEX WALL MOUNTED RECEPTACLEWP

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

1/4" = 1'-0"

E-101

POWER PLANS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

1/4" = 1'-0"1

Penthouse F - 36th Floor - Main Level PowerPlan

1/4" = 1'-0"2 Penthouse F - Upper Level Power Plan

ALL ELECTRICAL OUTLETS, FIXTURES, AND RELATED ITEMS BEING INSTALLED IN PUBLIC/PARTY/CHASEWALLS AND/OR CEILINGS MUST BE INSTALLED WITH SOUNDPROOF HOUSINGS AND/OR GASKETING.

GENERAL ELECTRICAL NOTES

No. Description Date

Page 26: Elam Pricing Full Set 4.3.15

DN

UP

GAS GAS GAS

GA

SG

AS

GA

SG

AS

GA

SG

AS

UP1 Riser

C.O.

A B

1

NEW WASTE LINE

PLUMBING LEGEND

NEW VENT LINE

NEW GAS LINE

NEW CLEAN OUT

WASTE RISER

GAS GAS

C.O.

VENT RISER

RISER SHUTOFF

BRANCH SHUTOFF

Scale:

ConsultantContactAddress

Phonee-mail

ARCHITCTS PLLC648 Broadway / Suite 402, New York, NY 10012T.212.254.5210F.212.254.4523

www.wilkinsonarchitects.com

New York: Registered Architect 027917-1Pennsylvania: Registered Architect 402561

National Council of Architectural Registration Board #52853

DOB Barcode

ATOZ Consulting Engineers, PCIlya Malyuchenko, P.E.363 7th Avenue3rd FloorNew York, NY [email protected]

ConsultantContactAddress

Phonee-mail

NYC Building RestorationRobert M. Hanna, P.E.9011 Northern BoulevardSuite 307Jackson Heights, NY [email protected]

MECHANICAL

STRUCTURAL

1/4" = 1'-0"

P-101

PLUMBING PLANS

ELAM RESIDENCE300 EAST 74TH STREET PENTHOUSE-F/36TH FLOORNEW YORK, NY 10021

04/03/2015

1/4" = 1'-0"1

Penthouse F - 36th Floor - Main LevelPlumbing Plan

1/4" = 1'-0"2 Penthouse F - Upper Level Plumbing Plan

EXISTING VENT STACK(VERIFY IN FIELD)

EXISTING WASTE STACK(VERIFY IN FIELD)

EXISTING WASTE STACK(VERIFY IN FIELD)

EXISTING 6" VENT STACK(VERIFY IN FIELD)

EXISTING 4" WASTE STACK(VERIFY IN FIELD)

EXISTING 4" VENTTO ROOF

(VERIFY IN FIELD)

W/D

EXISTING RISER SHUTOFF(VERIFY IN FIELD)

NEW FIXTURE SHUTOFF(ACCESS INSIDE B.C.)

No. Description Date