EL CID EVOLUTIONTM
The next generation in EL CID technology fordetecting stator core problems
IRIS POWER OFF-LINE PRODUCTS
EL CID EVOLUTION STATOR CORE TESTER
Finds core lamination shorts faster and with better accuracy
THE WORLD’S ONLY PROVEN LOW-FLUX INSTRUMENT
FOR EVALUATING STATOR CORES
![Page 2: ELCID_Ev_Broch](https://reader031.vdocument.in/reader031/viewer/2022021119/577d2d8f1a28ab4e1eadc003/html5/thumbnails/2.jpg)
8/7/2019 ELCID_Ev_Broch
http://slidepdf.com/reader/full/elcidevbroch 2/4
EL CID EVOLUTION
Electromagnetic CoreImperfection Detection (EL CID)testing is accepted world-wide
for reliable and safe detection of stator core inter-laminarinsulation faults.
Originally developed by theCEGB utility in England, theEL CID Evolution is the thirdgeneration of this reliable, easyto use, stator core test. EL CIDEvolution tests the condition of astator core in less time and withlower costs than earlier EL CIDmodels.
The EL CID Evolution test can beequally applied to turbinegenerators, hydro generators,and large motors.
IRIS POWER OFF-LINE PRODUCTS
Expanded analysis of one slo
Graph of inter-laminar current vs. core length and slo
Large fault signal
Map of EL CID readings over entire core(red areas show regions of shorted laminations)
![Page 3: ELCID_Ev_Broch](https://reader031.vdocument.in/reader031/viewer/2022021119/577d2d8f1a28ab4e1eadc003/html5/thumbnails/3.jpg)
8/7/2019 ELCID_Ev_Broch
http://slidepdf.com/reader/full/elcidevbroch 3/4
EL CID EVOLUTION
IRIS POWER OFF-LINE PRODUCTS
EL CID TESTING VS RING FLUX TESTING
The only alternative to the EL CID Evolution test is the Ring Flux (fullflux) test. The Ring Flux test requires large power supplies, considerable
manpower and expensive infrared viewing cameras. The El CID test hasthe following advantages compared to the Ring Flux test:
• EL CID test provides rapid testing of the machine, often less than onework shift for turbo generators and motors. The Ring Flux testtypically takes 3 work shifts
• only one technician is needed to perform the test, saving skilledresources and cost, instead of up to 6 technicians
• typical labor is reduced from 144 to 360 man-hours for a major turbogenerator Ring Flux test* to just 8 to 10 man-hours for EL CID test
• rapid setup to retest after any repair ensures quick turnaround
• minimize intrusive repairs by instantly verifying the results.
*Source – Westinghouse
Testing a hydro generator Testing a motor
NEW AND IMPROVEDFEATURES WITH THE
EL CID EVOLUTION• Faster test scanning (up to
120 mm/sec at 60 Hz)
• Easier excitation calculations
• Simpler testing with dualChattocks (detection coils)
• User-friendly LCD displayto guide user operation
• Combines step-iron data
with main core traces
• Easily identifies “hot spots”via color map display
• Fully compatible with datafrom earlier versions
ADVANTAGES
• Tests are repeatable
• Immediate test results areavailable for local analysisand email
• Determines if defectsare on the surface, underconductors, or sub-surface
• Tests with or withoutwindings
• Better detection of buriedfaults
• Partial retests of core arepossible, with ability tomerge results to obtain acomplete picture of thecore condition
• Trending of previous results
• Excellent quality assurancetest